Attachment_2_Drawings.pdf
PDF 41 MB Posted
- Attached to
- Weapons Storage Area (WSA) Alert Fire Team Facility Renovation Federal contract opportunity
- Solicitation number
- FA4528-17-R-0001
About this file
Attachment 2 Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_7_-_Questions_and_Answers_Final.pdf | ||
| FA4528-17-R-0001-0001.pdf | ||
| Attachment_1_Specifications.pdf | ||
| Attachment_5_Financial_Responsibility.docx | DOCX document | |
| Attachment_3_WDOL.pdf | ||
| Attachment_6_Construction_Cost_Breakdown.xlsx | XLSX spreadsheet | |
| Attachment_4_Past_Performance_Information_Form.docx | DOCX document | |
| FA4528-17-R-0001.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
LI
C
IT
A
TI
O
N N
O
FI
LE
N A
M E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
TI
O
N M
A R
K A
P P
R
D A
TE
FI
LE
N U
M B
E R
S
IZ
E
S U
B M
IT
TE
D B
Y
P
LO
T S
C A
LE
IS
S
U E
D A
TE
D A
TE
M
A R
K D
E S
C R
IP
TI
O N
C O
N
TR
A C
T N
O
SHEET
IDENTIFICATION
D A
TE
A
P P
R
SHEET OF 67
TE
A
M F
A C
IL
IT
Y , B
FA
-1
3- D
-0
1-
#24 A
P R
IL
A
P R
IL
A N
S I D
Q
JV
F1 3-
1:
R E
N O
V A
TE
W
S A
A
LE
R T
FI
R
E
0% D
E S
IG
N
A P
R
IL
C O
V E
R S
H E
E T
G-001
K H
A
K H
A
K H
A
B
_G
-0
.D W
G
K H
A
VICINITY MAP
SITE
PROJECT
NO SCALE SCALE: 1"=500'
MAFB PROJECT NO: QJVF 13-0034
RENOVATE WSA ALERT FIRE TEAM FACILITY, B1107
MINOT AFB, NORTH DAKOTA
LOCATION PLAN
24 APRIL 2015
BASE GATE
LOCATION
PROJECT
HAUL ROUTE
HI
GH
W
AY
BOMBER BLVD.
RD L
ST
RD K ST
BOMBER BLVD.
WEAPONS STORAGE AREA
ENTRY CONTROL POINT
LI
C
IT
A
TI
O
N N
O
FI
LE
N A
M E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
TI
O
N M
A R
K A
P P
R
D A
TE
FI
LE
N U
M B
E R
S
IZ
E
S U
B M
IT
TE
D B
Y
P
LO
T S
C A
LE
IS
S
U E
D A
TE
D A
TE
M
A R
K D
E S
C R
IP
TI
O N
C O
N
TR
A C
T N
O
SHEET
IDENTIFICATION
D A
TE
A
P P
R
SHEET OF 67
TE
A
M F
A C
IL
IT
Y , B
FA
-1
3- D
-0
1-
#24 A
P R
IL
A
P R
IL
A N
S I D
Q
JV
F1 3-
1:
R E
N O
V A
TE
W
S A
A
LE
R T
FI
R
E
0% D
E S
P
R
IL
LE
G
E N
D S
A
D
G E
N E
R A
L N
O
TE
S
G-002
K H
A
K H
A
K H
A
B
_G
-0
.D W
G
K H
A
EARTH
CONCRETE
GRAVEL
MASONRY VENEER
METAL
PLYWOOD
WOOD (FINISH)
WOOD (ROUGH)
GLASS (ELEVATION)
BLANKET INSULATION
RIGID INSULATION
GYPSUM WALLBOARD OR CEMENT
CONCRETE MASONRY UNITS (PLAN)
CONCRETE MASONRY UNITS (SECTION)
GLASS (LARGE SCALE SECTION)
N
TRUE
NORTH
ROOM NAME / NUMBER
DOOR NUMBER
WINDOW NUMBER
WALL TYPE
SIGN TYPE
KEY NOTE
FIBERBOARD SHEATHING
BOARD PANEL/TRIM AS INDICATED
DISCIPLINE DESIGNATOR (ARCH, STRUCT, MECH, ELEC, ETC.)
SHEET REFERENCE NUMBER
1. SHEET NUMBERS:
A -1 0 1
1. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, REGULATIONS, AND ORDINANCES.
2. THE CONTRACTOR SHALL PERFORM ALL TESTING AND INSPECTIONS AS SPECIFIED, OR AS
NECESSARY TO DEMONSTRATE A COMPLETE AND SATISFACTORY INSTALLATION.
3. THE CONTRACTOR SHALL PROTECT EXISTING BUILDING AND SITE MATERIALS SCHEDULED
TO REMAIN, AND SHALL BE RESPONSIBLE FOR DAMAGE TO THE SAME RESULTING FROM
WORK UNDER THIS CONTRACT. THE CONTRACTOR SHALL RESTORE DAMAGED EXISTING
BUILDING AND SITE MATERIALS TO THEIR ORIGINAL CONDITION.
4. CONTRACTOR SHALL EXERCISE CAUTION TO AVOID ANY DAMAGE WHEN PERFORMING
EARTHWORK, PAVING, OR ANY CONSTRUCTION IN THE VICINITY OF EXISTING UTILITIES,
BUILDINGS, AND LANDSCAPING.
5. CONTRACTOR SHALL INSPECT SITE AND FIELD VERIFY ALL DIMENSIONS AND CONDITIONS
PRIOR TO COMMENCING CONSTRUCTION. CONTRACTOR SHALL NOTIFY CONTRACTING
OFFICER IMMEDIATELY OF ANY DISCREPANCIES.
6. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, AND SHALL BE RESPONSIBLE FOR
PROPER FIT OF ALL ITEMS. CONTRACTOR SHALL COORDINATE ALL WORK AND SHOP
DRAWINGS WITH OTHER TRADES.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL WORK. CONTRACTOR
SHALL ANTICIPATE AREAS WHERE THE INSTALLATION OF MECHANICAL AND ELECTRICAL
WORK WILL BE RESTRICTED, CONGESTED, OR DIFFICULT TO INSTALL, AND SHALL
COORDINATE INSTALLATION BETWEEN THE TRADES.
8. CONTRACTOR SHALL COORDINATE LOCATIONS FOR ALL MECHANICAL AND ELECTRICAL
ITEMS WITH THE GENERAL CONSTRUCTION. CONTRACTOR SHALL NOTIFY CONTRACTING
OFFICER OF ANY DISCREPANCIES PRIOR TO INSTALLATION AND/OR FABRICATION.
9. ALL DIMENSIONS LOCATING BUILDING AND SITE IMPROVEMENTS ARE TO FACE OF BUILDING, BACK OF CURB, OR EDGE OF WALK, AND RUN PARALLEL OR PERPENDICULAR TO EXISTING
ROADS.
10. ALL BUILDING DIMENSIONS ARE TO FACE OF GWB, FACE OF MASONRY, OUTSIDE FACE OF
WALL SHEATHING AND EXTERIOR WINDOW OR DOOR ROUGH OPENING.
11. ALL ANGLES ON PLANS ARE 45- OR 90-DEGREES, UNLESS NOTED OTHERWISE.
12. ALL ELEVATIONS INDICATED ON THE DRAWINGS ARE BASED ON A FIRST FLOOR DATUM OF
+100'-0”. WHERE ITEMS ARE LABELED A.F.F. (ABOVE FINISHED FLOOR), CONTRACTOR SHALL
SET THE ITEM AS MEASURED FROM THE LOCAL FLOOR ELEVATION. COORDINATE ANY
DISCREPANCIES REGARDING THIS SITUATION TO ASSURE THAT ALL BUILDING COMPONENTS
ARE PROPERLY SET TO FUNCTION AS INTENDED. CONTRACTOR SHALL ERECT ALL
PARTITIONS IN A VERTICAL PLANE, NOT NECESSARILY PERPENDICULAR TO THE FLOOR.
13. ALL MATERIALS AND EQUIPMENT OF THE SAME TYPE SHALL BE SUPPLIED BY THE SAME
MANUFACTURER, AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM
DEFECTS.
14. ALL ITEMS ARE NEW UNLESS SPECIFICALLY IDENTIFIED AS EXISTING.
15. SEE LIFE SAFETY PLAN FOR LOCATIONS OF FIRE- AND SMOKE-RATED PARTITIONS.
16. INSTALL BLOCKING WITHIN PARTITIONS AS REQUIRED FOR INSTALLATION OF
WALL-MOUNTED CABINETS, TOILET ACCESSORIES, WALL STOPS, AND MISCELLANEOUS
ITEMS.
17. LOCATE INTERIOR CONTROL JOINTS WHERE INDICATED, BUT AT A MINIMUM TO DIVIDE ALL
GYPSUM BOARD INTO SECTIONS NOT EXCEEDING 30-FEET IN LENGTH.
18. ALL CEILING GRID SHALL BE CENTERED WITHIN THE ROOM OR CORRIDOR IN WHICH IT
OCCURS, UNLESS SHOWN OTHERWISE.
19. ALL CEILING HEIGHTS LISTED IN THE ROOM FINISH SCHEDULE ARE FROM THE FINISH FLOOR
OF THE LISTED ROOM, UNLESS NOTED OTHERWISE.
20. ALL CHANGES IN FLOOR MATERIALS OCCUR AT THE FOLLOWING LOCATIONS, UNLESS NOTED
OTHERWISE: 1) AT THE CENTER LINE OF DOORS IN THE CLOSED POSITION, OR; 2) AT THE
CENTER LINE OF OPENINGS SEPARATING ROOMS.
21. ALL INTERIOR WALLS ARE PARTITION TYPE A1, UNLESS NOTED OTHERWISE. SEE SHEET
A-101 FOR PARTITION TYPES.
22. ALL GYPSUM BOARD IS 5/8” THICK, UNLESS NOTED OTHERWISE.
23. ALL METAL STUDS ARE 3-5/8” WIDE, UNLESS NOTED OTHERWISE.
24. WHERE METAL STUDS EXTEND TO THE STRUCTURE ABOVE, PROVIDE DOUBLE-HEAD OR SLIP
TRACK TO ALLOW FOR 3/4” MINIMUM DEFLECTION OF THE STRUCTURE.
25. ALL MASONRY REINFORCEMENT IS INDICATED ON THE STRUCTURAL DRAWINGS.
26. ALL EXTERIOR CONTROL JOINTS SHALL RECEIVE BACKER ROD AND SEALANT.
27. IN SOME INSTANCES, THERMAL AND SOUND INSULATION HAS BEEN OMITTED FROM DETAILS
FOR CLARITY. SEE SPECIFICATIONS, PARTITION TYPES, AND WALL SECTIONS FOR
LOCATIONS REQUIRING INSULATION.
28. THE PLANS AND SPECIFICATIONS ARE NOT INTENDED TO DEPICT EACH AND EVERY
CONDITION OR DETAIL OF CONSTRUCTION IN REGARD TO THE AIR AND MOISTURE BARRIER.
THE CONTRACTOR HAS RESPONSIBILITY FOR ENSURING THE AIR- AND WATER-TIGHT
INTEGRITY OF THE STRUCTURE.
29. UTILITY LOCATIONS SHOWN ARE BASED ON A REVIEW OF GOVERNMENT-PROVIDED
DRAWINGS, WHICH SHALL BE VERIFIED BY THE CONTRACTOR.
GENERAL NOTES
INDEX LEGEND
ARCHITECTURAL LEGEND
LEGEND NOTES
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE
PERTINENT TO THE CONDITIONS ON THIS SET OF DRAWINGS TO THE
EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ANOTHER LEGEND SHEET MAY
APPEAR IN THIS SET OF DRAWINGS TO INDICATE SPECIFIC
CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
STANDARD NORTH ARROWS
SECTION IDENTIFICATION
SHEET NUMBERS OMITTED IF SECTION IS CUT AND DETAILED ON SAME
DRAWING.
SHEET NUMBER OF DRAWING WHERE SECTION IS
SHOWN
ELEVATION IDENTIFICATION
DIRECTION OF SIGHT OF
ELEVATION ON PLAN
SHEET NUMBER OF DRAWING
WHERE ELEVATION IS SHOWN
DIRECTION OF SIGHT OF
ELEVATION ON PLAN
SHEET NUMBER OF DRAWING
WHERE ELEVATION IS SHOWN
SECTION NUMBER
ARCHITECTURAL SYMBOLS
ROOM
NAME
SHEET TYPE DESIGNATOR; FOR EXAMPLE 1 WOULD BE FLOOR
PLANS, 2 ELEVATIONS, 3 SECTIONS, ETC.
(SEE A/E/C CADD STANDARDS)
N
PLAN
NORTH
A-501
A-401
B
A
D
C
A A-401
INDEX OF DRAWINGS
GENERAL
G-001 COVER SHEET
G-002 INDEX OF DRAWINGS, LEGEND AND GENERAL NOTES
G-003 ABBREVIATIONS
G-004 LIFE SAFETY ANALYSIS AND PLAN
SURVEY/MAPPING
V-101 TOPOGRAPHIC SURVEY
CIVIL
CD101 REMOVAL PLAN
C-101 GRADING AND EROSION CONTROL
C-102 UTILITY PLAN
C-103 PAVING PLAN
C-104 CIVIL DETAILS
STRUCTURAL
S-001 STRUCTURAL GENERAL NOTES
S-101 FOUNDATION PLAN, EXISTING ROOF FRAMING PLAN & ROOF FRAMING PLAN
S-201 FOUNDATION DETAILS
S-301 DETAILS AND SECTIONS
S-302 DETAILS AND SECTIONS
ARCHITECTURAL
AD101 REMOVAL PLAN
A-101 FLOOR PLAN AND WALL TYPES
A-102 CEILING PLAN AND ROOF PLAN
A-201 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-302 WALL SECTIONS
A-303 WALL SECTIONS
A-304 WALL SECTIONS
A-401 ENLARGED FLOOR PLANS
A-402 INTERIOR ELEVATIONS AND CASEWORK SECTIONS
A-501 DETAILS
A-502 DETAILS
A-601 ROOM FINISH SCHEDULE AND INTERIOR SIGNAGE
A-602 DOOR SCHEDULE AND ELEVATIONS
A-701 FRAME DETAILS
A-702 FRAME DETAILS
FIRE PROTECTION
FG101 FIRE PROTECTION SYMBOLS LEGEND AND GENERAL NOTES
FX101 FIRE SUPPRESSION FLOOR PLAN
FX201 FIRE PROTECTION DETAILS AND SCHEDULES
FA101 FIRE ALARM FLOOR PLAN
FA201 FIRE ALARM RISERS AND DETAILS
PLUMBING
PG001 PLUMBING SYMBOLS LEGEND AND GENERAL NOTES
PD101 PLUMBING DEMOLITION FLOOR PLANS
P-101 PLUMBING FLOOR PLANS
P-201 ENLARGED PLUMBING FLOOR PLANS
P-401 SANITARY SEWER AND VENT RISER
P-402 DOMESTIC WATER AND NATURAL GAS RISER
P-501 PLUMBING DETAILS
P-601 PLUMBING FIXTURE AND EQUIPMENT SCHEDULES
MECHANICAL
MG001 MECHANICAL SYMBOLS LEGEND
MG002 MECHANICAL GENERAL NOTES
MD101 HVAC DEMOLITION FLOOR PLAN
MD201 HVAC PIPING DEMOLITION FLOOR PLAN
MH101 HVAC FLOOR PLANS
MP101 HVAC PIPING FLOOR PLANS
M-301 MECHANICAL SECTIONS
M-401 MECHANICAL CONTROLS
M-402 MECHANICAL CONTROLS
M-501 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-603 MECHANICAL SCHEDULES
ELECTRICAL
EG001 ELECTRICAL SYMBOLS LEGEND AND GENERAL NOTES
ES101 ELECTRICAL SITE PLAN
ED101 ELECTRICAL DEMOLITION FLOOR PLAN
EL101 LIGHTING FLOOR PLAN
EP101 POWER FLOOR PLAN
EY101 SPECIAL SYSTEMS FLOOR PLAN
E-401 ELECTRICAL RISER DIAGRAMS
E-501 ELECTRICAL DETAILS
E-601 ELECTRICAL SCHEDULES
E-602 ELECTRICAL SCHEDULES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
ASBESTOS AWARENESS
TESTING FOR ASBESTOS WAS PERFORMED. ASBESTOS CONTAINING
MATERIALS WERE IDENTIFIED. SEE SPECIFICATION SECTION 01 57 20
ENVIRONMENTAL PROTECTION, AND THE DRAWINGS FOR EXTENT OF
IDENTIFIED MATERIALS AND REMOVAL WORK. IF DURING REMOVAL WORK,
THE CONTRACTOR DISCOVERS ANY ADDITIONAL MATERIALS WHICH HE
SUSPECTS MAY CONTAIN ASBESTOS, HE SHALL IMMEDIATELY NOTIFY THE
CONTRACTING OFFICER. THE CONTRACTING OFFICER WILL THEN
ARRANGE FOR TESTING AND REMOVAL OF ANY ADDITIONAL MATERIALS IF
PRESENT.
LEAD BASED PAINT AND LEAD AWARENESS
NON-DESTRUCTIVE TESTING FOR LEAD BASED PAINT (LBP) HAS BEEN
PERFORMED. LBP WAS IDENTIFIED IN THE EXISTING WORK AREAS TO
REMAIN, SEE SPECIFICATIONS SECTION 01 57 20 ENVIRONMENTAL
PROTECTION FOR EXTENT OF IDENTIFIED MATERIALS.
IF DURING REMOVAL WORK, THE CONTRACTOR DISCOVERS ANY OTHER
PAINT WHICH HE SUSPECTS MAY CONTAIN LEAD, HE SHALL IMMEDIATELY
NOTIFY THE CONTRACTING OFFICER. THE CONTRACTING OFFICER WILL
THEN ARRANGE FOR TESTING AND REMOVAL OF ANY LEAD IF PRESENT.
THE CONTRACTOR IS ADVISED THAT RENOVATION-RELATED ACTIVITIES
MAY GENERATE AIRBORNE CONCENTRATIONS OF LEAD THAT WOULD
REQUIRE PRECAUTIONS TO PROTECT PERSONNEL FROM POTENTIAL
EXPOSURE. SINCE OSHA DOES NOT DEFINE LBP, THE REQUIREMENTS OF
THE STANDARD FOR CONSTRUCTION (29 CFR 1926.62) APPLY IF ANY
AMOUNT OF LEAD IS PRESENT IN BUILDING MATERIALS. AT A MINIMUM,
THE CONTRACTOR IS REQUIRED TO PROVIDE EMPLOYEE PROTECTION
THAT MIGHT INCLUDE RESPIRATORY PROTECTION APPROPRIATE TO THE
TASK AND CONDUCT INITIAL, REPRESENTATIVE MONITORING.
LI
C
IT
A
TI
O
N N
O
FI
LE
N A
M E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
TI
O
N M
A R
K A
P P
R
D A
TE
FI
LE
N U
M B
E R
S
IZ
E
S U
B M
IT
TE
D B
Y
P
LO
T S
C A
LE
IS
S
U E
D A
TE
D A
TE
M
A R
K D
E S
C R
IP
TI
O N
C O
N
TR
A C
T N
O
SHEET
IDENTIFICATION
D A
TE
A
P P
R
SHEET OF 67
TE
A
M F
A C
IL
IT
Y , B
FA
-1
3- D
-0
1-
#24 A
P R
IL
A
P R
IL
A N
S I D
Q
JV
F1 3-
1:
R E
N O
V A
TE
W
S A
A
LE
R T
FI
R
E
0% D
E S
P
R
IL
A B
B R
E V
IA
TI
O
G-003
K H
A
K H
A
K H
A
B
_G
-0
.D W
G
K H
A
A
AB ANCHOR BOLT
AC ALTERNATING CURRENT
A/C AIR CONDITIONING
ACI AMERICAN CONCRETE INSTITUTE
ACSR ALUMINUM CONDUCTOR STEEL
REINFORCED
ACST ACOUSTIC
AD ACCESS DOOR
A.D. AREA DRAIN
ADMIN. ADMINISTRATION/ADMINISTRATIVE
AECS AUTOMATED ENTRY CONTROL
SYSTEM
A.F.F. ABOVE FINISH FLOOR
AFFF AQUEOUS FILM FORMING FOAM
AGG AGGREGATE
AHU AIR HANDLING UNIT
A.I. AREA INLET
AIC AMPS INTERRUPTING
CAPACITY (SYM RMS)
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
AL ALUMINUM
A.L. ACTIVE LEAF
ALT ALTERNATE
AMP AMPERE
ANSI AMERICAN NATIONAL
STANDARDS INSTITUTE
AP ACCESS PANEL
APPD APPROVED
APROX. APPROXIMATE
ARCH ARCHITECTURAL OR ARCHITECT
A.R.I. AMERICAN REFRIGERATION
INSTITUTE
ASB ASBESTOS
ASPH ASPHALT
ASSIST. ASSISTANT
ATC ACOUSTICAL TILE CEILING
AUTO AUTOMATIC
AVG AVERAGE
AWC ACOUSTICAL WALL COVERING
AWG AMERICAN WIRE GAUGE
ANGLE
B
BATT INSUL BATT INSULATION
BB BULLETIN BOARD
BC BOOKCASE
BD BOARD
BDY BOUNDARY
BEJ BRICK EXPANSION JOINT
BIT BITUMINOUS
BL BUILDING LINE
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
B.M. BENCH MARK
B.O. BOTTOM OF
BOT BOTTOM
BR BULLET RESISTANT
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRK BRICK
BRKT BRACKET
BT BENT
BTU BRITISH THERMAL UNIT
BTUH BTU PER HOUR
BUR BUILT-UP ROOFING
C C or CND CONDUIT (FOR RACEWAY-
ELECTRICAL SHEETS)
CAP CAPACITY
CATV CABLE TELEVISION
CC CENTER TO CENTER
CB CATCH BASIN (OR CIRCUIT
BREAKER)
CE COVER ELEVATION
CEM CEMENT
CFM CUBIC FEET PER MINUTE
CFT CERAMIC FLOOR TILE
C.F.C.I. CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
C.F.G.I. CONTRACTOR FURNISHED
GOVERNMENT INSTALLED
CHIM CHIMNEY
C.I. CURB INLET
CI CAST IRON
CIR CIRCULAR
CJ CONTROL JOINT
CKD CHECKED
CKT CIRCUIT
CKTBKR or CB CIRCUIT BREAKER
CL CENTER LINE
CLG CEILING
C (cont.)
CLK CLERK
CLKG CAULKING
CLO CLOSET
CLOS CLOSED
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNITS
CNTR COUNTER
CO CLEANOUT
CO₂ CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION
COMB COMBUSTION
COMP COMPRESSIBLE
COMM COMMUNICATIONS
CONC. CONCRETE
CONF. CONFERENCE
CONN CONNECTION
CONSTR CONSTRUCTION
CONSTR JT. CONSTRUCTION JOINT
CONT CONTINUOUS
COR CORNER
CORR CORRIDOR
COV COVERED
CPL CEMENT PLASTER
CPT CARPET
C.P.S. ~ CYCLES PER SECOND (HERTZ)
CRES CORROSIVE RESISTANT STEEL
CRG CARRIAGE
CRSE COURSE
CS COUNTER SINK
CST CAST STONE TILE
CSMT CASEMENT
CT CERAMIC TILE or CURRENT
TRANSFORMER
CTG CLEAR TEMPERED GLASS
CTIG CLEAR TEMPERED INSULATING
GLASS
CTL CARPET TILE
CTR CENTER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CU YD CUBIC YARDS
CV CEILING VENT
CW COLD WATER
CWT CERAMIC WALL TILE
CYL CYLINDER
D d PENNY (as in nail - 10d)
D DATUM
DA DOUBLE ACTING
DB DRY BULB
DBL DOUBLE
DC DIRECT CURRENT
D.C.J. DOWELED CONTROL JOINT
DCJT DUMMY CONTOL JOINT
DCL DOOR CLOSER
DEG DEGREE
DEPR DEPRESSION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DH DUCT HEATER
DIA or ø DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIR DIRECTOR
DISSEM DISSEMANATION
DISC DISCONNECT
DIST DISTRIBUTION
D & M DRESSED & MATCHED
DN DOWN
DP DAMPPROOFING
DR DOOR
DRN DRAIN
DS DOWN SPOUT
DWG DRAWING
DWLS DOWELS
DX DIRECT EXPANSION
E
E EAST
EA. EACH
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EES EMERGENCY EYEWASH & SHOWER
EIFS EXTERIOR INSULATION &
FINISH SYSTEM
EJ EXPANSION JOINT
EL or ELEV. ELEVATION - GRADE OR BUILDING ELEC. ELECTTRIC or ELECTRICAL
ELEV ELEVATOR
EMD ESTIMATED MAXIMUM DEMAND
ENCL ENCLOSURE
F
F FAHRENHEIT
FA FRESH AIR
FC FOOT CANDLE
FCG FACING
FCJ FLOOR CONSTRUCTION JOINT
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
F.D. FIRE DAMPER
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEB FIRE EXTINGUISHER BRACKET
FEC FIRE EXTINGUISHER CABINET
F.E.S FLARED END SECTION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIG. FIGURE
FIN. FINISH
FIX. FIXTURE
FL or FLR FLOOR
FLASH FLASHING
FLEX FLEXIBLE
FLG FLOORING
FLUOR FLUORESCENT
FOS FACE OF STUD
F.O. FIBER OPTIC
FP FIRE PROTECTION
FPM FEET PER MINUTE
FPRF FIRE PROOF
FR FRAME
FRG FURRING
F.S. FULL SIZE
FSF FABRIC SILT FENCE
FT. FEET
FTG. FOOTING
FW FIRE WATER
FWC FABRIC WALL COVERING
G
G GAS
G GUTTER
GA GAGE or GAUGE
GAL GALLON
GALV GALVANIZED
G.C.O. GROUND CLEANOUT
GEN GENERAL
G.F.C.I. GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
G.F.G.I. GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GFE GOVERNMENT FURNISHED
EQUIPMENT
G.F.I. or GFI GROUND FAULT INTERRRUPTOR
GFRP GLASS FIBER REINFORCED
PLASTER
GI GALVANIZED IRON
GL GLASS
GND or GRND GROUND
GOVT. GOVERNMENT
GPM GALLONS PER MINUTE
GR GRADE
GRS GALVANIZED RIGID STEEL
CONDUIT
GRTG GRATING
GSU GRAZED STRUCTURAL UNITS
GWB GYPSUM WALLBOARD
GWT GLAZED WALL TILE
GYP GYPSUM
H
HB HOSE BIBB
HBD HARDBOARD
HC HANDICAPPED
HCD HALON CONTAINMENT DAMPER
HD HEAD
HDR HEADER
HDRL HANDRAIL
HDW HARDWARE
I I or EF IRON
IC INTERCOM
I.D. INSIDE DIAMETER
IDS INTRUSION DETECTION SYSTEM
I.E. INVERT ELEVATION
IES ILLUMINATING ENGINEERING
SOCIETY
IN INCH
INSUL. INSULATION
INT. INTERIOR
INV. INVERT or INVERTER
I.P. IRON PIPE
J JB or J-BOX JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JST JOIST
JT JOINT
K
K KEY
kcmil or KCM KILO CIRCULAR MIL
KCP KEENE'S CEMENT PLASTER
KIP KILOPOUND (1000 LBS)
KIT KITCHEN
KL KEY LOCK
KP KICK PLATE
kV KILOVOLTS kVA KILOVOLT AMPERES kvar KILOVOLT AMPERES REACTIVE kW KILOWATT
L
L LUMEN
LAB LABORATORY
LAT LEAVING AIR TEMPERATURE
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUNDS
LD LOAD
LDG LOADING
LG LENGTH
LIN LINEAR
LIS LAWN IRRIGATION SYSTEM
LNTL LINTEL
LONG LONGITUDINAL
LP LOW POINT
LPS LIGHT PROOF SHADE
LR LIVING ROOM
L.R. LONG RADIUS
LT LIGHT
LTG LIGHTING
LT. WT. LIGHT WEIGHT
LWT LEAVING WATER TEMPERATURE
M
M THOUSAND
MACH MACHINE
MAINT. MAINTENANCE
MAS MASONRY
MAT or MATL MATERIAL
MAX MAXIMUM
M & B MATCHED & BEADED
MC MEDICINE CABINET
MCJ MASONRY CONTROL JOINT
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MER MECHANICAL EQUIPMENT ROOM
MET. METAL
MFG MANUFACTURING
MFR MANUFACTURER
N
N NORTH
N.C. NORMALLY CLOSED
NCO NON COMMISSIONED OFFICER
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NU or NO. NUMBER
N.O. NORMALLY OPEN
N.R. NOT REQUIRED
O
O.A. OUTSIDE AIR
OBGL OBSCURE GLASS
OBSC OBSCURE
OB WG OBSCURE WIRE GLASS
OC ON CENTER
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OFF. OFFICE
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPS OPERATIONS
O.R. OBSERVATION RISER
OS & Y OUTSIDE SCREW & YORK
P
P PAINT
PA PUBLIC ADDRESS
PART PARTICLE
PBS PUSH BUTTON STATION
P.C.C. PORTLAND CEMENT CONCRETE
P.C. POINT OF CURVATURE
PC PIECE
PERF PERFORATED
P.E. POLYETHYLENE
PH or ø PHASE
PHAR PHARMACY
P.I. POINT OF INTERSECTION
P.I.V. POST INDICATOR VALVE
PL PLATE
PLAS PLASTER
PL PLASTIC LAMINATE
PLATF PLATFORM
PLBG PLUMBING
PLG PILING
PLY. WD. PLYWOOD
PNL PANEL
POL POLISH
PORC PORCELAIN
PP PAINTED PANEL
P.P.M. PARTS PER MILLION
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PROC PROCESSING
PROJ PROJECT
PRV PRESSURE REGULATING VALVE
P.S. PRESSED STEEL
PSF POUNDS/SQUARE FOOT
PSI POUNDS/SQUARE INCH
P.T. POINT OF TANGENCY
PT POINT or POTENTIAL (VOLTAGE)
TRANSFORMER
PTD PAINTED
PTN PARTITON
PVC POLYVINYL-CHLORIDE
PVMT PAVEMENT
PW PASS WINDOW
E (cont.)
ENT ENTRANCE
E.P. EXPLOSION PROOF
EQ. EQUAL
EQUIP. EQUIPMENT
ES EACH SIDE
EST ESTIMATE
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
EXC EXCAVATE
EXD EXIT DEVICE
EXH EXHAUST
EXIST. EXISTING
EXP EXPOSED
EXPL EXPLOSION
EXPN EXPANSION
EXT EXTERIOR
H (cont.)
HM HOLLOW METAL
HP HORSE POWER
HPL HIGH PRESSURE LAMINATE
FLOORING
HIP HIGH PRESSURE
H.PT. HIGH POINT
HR HOUR
H.S. HIGH STRENGTH
HSGYP HIGH-STRENGTH GYPSUM
PLASTER
HT HEIGHT
HTG HEATING
HTR HEATER
H.W. HEADWALL
HW HOT WATER
HWH HOT WATER HEATER
HYD HYDRAULIC
HZ HERTZ
M (cont.)
MG MOTOR GENERATOR
MGT MATTE - GLAZED TILE
MGMT MANAGEMENT
M.H. MANHOLE
MIN MINIMUM
ML METAL LATH
MLDG MOULDING
MO MASONRY OPENING
MONO MONOLITHIC
MOT MOTOR
MS MOTOR STARTER
MSTC MASTIC
MT METAL THRESHOLD
MTD MOUNTED
T
T TREAD
TAN. TANGENT
TBD TACK BOARD
TC TOP OF CURB
TCA TILE COUNCIL OF AMERICA
T.E. TOP ELEVATION
U
UC UNIT COOLER
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
UNEX UNEXCAVATED
UNFIN UNFINISHED
UPS UNINTERRUPTIBLE POWER
SYSTEM
UR URINAL
UT UTILITY
UV UNIT VENTILATOR
V
V VOLT
VB VINYL BASE
VCP VITRIFIED CLAY PIPE
V.C.T. VINYL COMPOSTION TILE
VD VAULT DOOR
VENT VENTILATION
VENT VENTILATOR
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
V.P.C. VERTICAL POINT OF CURVATURE
V.P.I. VERTICAL POINT OF
INTERSECTION
V.P.T. VERTICAL POINT OF TANGENCY
V.R. VAPOR RETARDER
VS VENT STACK
VT VINYL-TILE OR VOLTAGE
TRANSFORMER
VTR VENT THRU ROOF
VWC VINYL-WALL COVERING
W
W WEST
W WIRE
W/ WITH
WB WET BULB
WC WATER CLOSET
WC WALLCOVERING
WCO WALL CLEANOUT
WD WOOD
W.D. WASTE DRAIN
WD. BLK. WOOD BLOCKING
WD. DR. WOOD DOOR
WDW WINDOW
WF WIDE FLANGE
WG WIRE GLASS
WH WALL HYDRANT
WHM WATTHOUR METER
WHT WHITE
W.I. WROUGHT IRON
WKSH WORK SHOP
WNSCT WAINSCOT
W/O WITHOUT
WP WALL PANEL
WP WEATHER PROOF
WPF WATER PROOF
WPFG WATER PROOFING
WRB WARDROBE
WS WASTE STACK
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WOVEN WIRE MESH
X
XFMR TRANSFORMER
Y
YD YARD
Y.D. YARD DRAIN
Q
QT QUART
Q.T. QUARRY TILE
QTRS QUARTERS
1/4 RD QUARTER ROUND
R R or RSR RISER
R.A. RETURN AIR
RAD or R RADIUS
RAG RETURN AIR GRILLE
RAR RETURN AIR REGISTER
RB RESILIENT BASE
RC REMOTE CONTROL
R.C.P. REINFORCED CONCRETE PIPE
RCVR RECEIVER
RD ROUND
R.D. ROOF DRAIN
RDGE RIDGE
RECP RECEPTACLE
RECR RECREATION
RECT. RECTIFIER
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCEMENT
REM REMOVABLE
REPRO REPRODUCTION
REQD REQUIRED
RESIL. RESILIENT
REV REVISIONS
RFG ROOFING
RFS RAISED FLOOR SYSTEM
RGE RANGE
RGH ROUGH
RH RELATIVE HUMIDITY
RM ROOM
RPM REVOLUTIONS PER MINUTE
RPRT RAISED PATTERN RUBBER TILE
RT RUBBER TILE
RUB RUBBER
S
S SOUTH
S.A. SUPPLY AIR
SB SPLASH BLOCK
S.B. SECURITY BARS
SC SPECIAL COATING
SCH SCHEDULE
SCIF SENSITIVE COMPARTMENTED
INFORMATION FACILITY
SCR SCREW
SCT STRUCTURAL CLAY TILE
SCUT SCUTTLE
S.D. SUBDRAIN
SDI STEEL DECK INSTITUTE
SJI STEEL JOIST INSTITUTE
SECT SECTION
SECY SECRETARY
SEQ SEQUENCE
S.F. SQUARE FOOTAGE
SFU STRUCTURAL FACING UNIT
SHLD. SHOULDER
SHT. SHEET
SHTG SHEATHING
SIM SIMILAR
SK SINK
SOV SHUT OFF VALVE
SP STATIC PRESSURE
SPEC SPECIFICATIONS
SPF SOUNDPROOF
SPH SPACE HEATER
SPKR SPEAKER
SPL SPECIAL
SQ SQUARE
SQUAD SQUADRON
SS SOLID SURFACE
SSMR STANDING SEAM METAL ROOFING
S. STL. STAINLESS STEEL
ST STAIN
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STGR STRINGER
STL STEEL
STN STONE
STOR STORAGE
STRUCT STRUCTURAL
STWY STAIRWAY
SUB FL SUB FLOOR
SUSP SUSPENDED
SVF SHEET VINYL FLOORING
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
T (cont.)
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TERM TERMINAL
TGL TOGGLE
TH THRESHOLD
THK THICK
T.O. TOP OF
TOS TOP OF STEEL
TOIL TOILET
TOPO TOPOGRAPHY
TRANS TRANSVERSE
T'STAT THERMOSTAT
TT TERRAZZO TILE
TV TELEVISION
TYP TYPICAL
ABBREVIATIONS
C.G. CORNER GUARD
F.V. FIELD VERIFY
ACD B
RTES SERVER
LDA ROOM
LDA SERVER
108A
GARAGE
BREAKROOM /
TACTICAL TRAINING
COMMENTRY
JANITOR
COMPUTER
TRAINING
OFFICE ENTRY
MENWOMENTLT
MECHANICAL/
ELECTRICAL
CORRIDOR
CORRIDOR
79' TRAVEL DISTANCE
27' TRAVEL DISTANCE
SCALE: 1/8" = 1'-0" 8'4'0 16'
LIFE SAFETY PLAN N
TRUE
NORTH
PLAN
NORTH
N
105' TRAVEL DISTANCE
63' TRAVEL DISTANCE
40' COMMON PATH DISTANCE
78' COMMON PATH DISTANCE
FEC
FEC
FEC
FEC
S O
LI
C
IT
A
TI
O
N N
O
FI
LE
N A
M E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
TI
O
N M
A R
K A
P P
R
D A
TE
FI
LE
N U
M B
E R
S
IZ
E
S U
B M
IT
TE
D B
Y
P
LO
T S
C A
LE
IS
S
U E
D A
TE
D A
TE
M
A R
K D
E S
C R
IP
TI
O N
C O
N
TR
A C
T N
O
SHEET
IDENTIFICATION
D A
TE
A
P P
R
SHEET OF 67
TE
A
M F
A C
IL
IT
Y , B
FA
-1
3- D
-0
1-
#24 A
P R
IL
A
P R
IL
A N
S I D
Q
JV
F1 3-
1:
R E
N O
V A
TE
W
S A
A
LE
R T
FI
R
E
0% D
E S
P
R
IL
LI
FE
S A
FE
TY
A N
A
LY
IS
D
P
LA
N
G-004
K H
A
K H
A
K H
A
B
_G
-0
.D W
G
K H
A
SMOKE PARTITION PER NFPA 101, SECTION 8.7.1.2
(THIS SHEET IS FOR INFORMATION ONLY)
EXIT
2012 IBC International Building Code (Note: The following are direct or paraphrased sections from the aforementioned Code, unless indicated by italics) Sect 202 AREA, BUILDING. The area included within surrounding exterior walls exclusive of vents shafts and courts.
Note: This definition of building area is taken to the inside face of the exterior walls. The DoD's definition of building area is taken to the outside face of the exterior walls. This accounts for the inconsistency in building area within the Design Analysis.
Actual building size to outside face of exterior walls is 5,174 SF. Actual building size to inside face of exterior walls is 4,644 SF.
Sect 304.1 Business Group B for the administration portion of the building.
Sect 311.3 Low-hazard Storage Group S-2 for the garage.
Table 503 For Group B (most restrictive occupancy), Type V-B construction, maximum building height shall be 40-feet; maximum building size per story shall be 9,000 SF, and maximum stories shall be 2.
Sect 506.3 Where a building is equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, the building area limitation in Table 503 is permitted to be increased by an additional 300-percent for buildings with no more than one story above grade plane.
Note: This increases the maximum building size per story to 36,000 SF.
Actual building height is approximately 22'-0"; actual building size is 4,612 SF; and actual stories are 1.
Sect 508.3 Nonseparated Occupancies. Buildings or portions of buildings that comply with the provisions of this section shall be considered as nonseparated occupancies.
Sect 508.3.1 Occupancy classification. Nonseparated occupancies shall be individually classified in accordance with Section 302.1. The requirements of this code shall apply to each portion of the building based on the occupancy classification of that space. In addition, the most restrictive provisions of Chapter 9 which apply to the nonseparated occupancies shall apply to the total nonseparated occupancy area.
Sect 508.3.2 The allowable building area and height of the building or portion thereof shall be based on the most restrictive allowances for the occupancy groups under consideration for the type of construction of the building in accordance with Section 503.1.
Sect 508.3.3 Separation. No separation is required between nonseparated occupancies.
Table 509 Fire separation not required around mechanical rooms with automatic sprinkler system.
Table 601 No rating required for structural frame, interior and exterior bearing walls, interior nonbearing walls, floor construction, or roof construction with Type V-B construction.
Note: Per the UFC, comply with NFPA 101 for fire-resistance rating of interior nonbearing walls.
Table 602 No rating required for exterior nonbearing walls where separation distance is greater than 10-feet.
Sect 602.5 Type V construction is that type of construction in which the structural elements, exterior walls and interior walls are of any materials permitted by this code.
Sect 705.11 Exception 1. A parapet need not be provided on an exterior wall where the wall is not required to be fire-resistance rated in accordance with Table 602 because of fire separation distance.
Chapter 8 Not used. Refer to UFC 3-600-01.
Chapter 9 Not used. Refer to UFC 3-600-01.
Chapter 10 Not used. Refer to UFC 3-600-01.
Chapter 11 Not used. Refer to ADA and ABA Accessibility Guidelines for Buildings and Facilities.
Sect 1210.2.2 Walls within 2-feet of service sinks, urinals and water closets shall have a smooth, hard, non-absorbent surface to a height of 4-feet above the floor, and the materials used in such walls shall be of a type that is not adversely affected by moisture.
Sect 2603.4.1.4Exterior walls - one-story buildings. For one-story buildings, foam plastic having a flame spread index of 25 or less, and a smoke-developed index of not more than 450, shall be permitted without thermal barriers in or on exterior walls in a thickness not more than 4-inches where the foam plastic is covered by a thickness of not less than 0.032-inch aluminum or corrosion-resistant steel having a base metal thickness of 0.016-inch and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.
2015 NFPA 101 Life Safety Code (Note: The following are direct or paraphrased sections from the aforementioned Code, unless indicated by italics) Chapters 1 thru 6 not used. Refer to the IBC and UFC 3-600-01.
Sect 3.3.190.3 Business Occupancy. An occupancy used for the transaction of business other than mercantile.
Sect 3.3.190.15 Storage Occupancy. An occupancy used primarily for the storage or sheltering of goods, merchandise, products, or vehicles.
Sect 6.2.2.3 Ordinary hazard contents shall be classified as those that are likely to burn with moderate rapidity or to give off a considerable volume of smoke.
Sect A.6.2.2.3 Ordinary hazard classification represents the conditions found in most buildings and is the basis of the general requirements of this Code.
Sect 7.2.1.2.3.2 Door openings in means of egress shall be not less than 32-inches in clear width.
Sect 7.2.1.4.2 Doors shall swing in the direction of egress travel under any of the following conditions:
1. Where serving a room or area with an occupant load of 50 or more.
2. Where the door assembly is used in an exit enclosure.
3. Where the door opening serves a high hazard contents area.
Table 7.3.1.2 Business Use: 100 gross SF per occupant.
Storage Use (in storage occupancies): No requirement.
Table 7.3.3.1 0.2-inch per occupant required width of level components for areas of building that are not high hazard.
Sect 7.4.1.1 The number of means of egress from any balcony, mezzanine, story, or portion thereof shall be not less than two.
Sect 7.5.1.3.3 In buildings protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7, the minimum separation distance between two exits, exit accesses, or exit discharges shall be not less than one-third the length of the maximum overall diagonal dimension of the building or area to be served.
Sect 7.5.1.6 Exit access from rooms or spaces shall be permitted to be through adjoining or intervening rooms or areas, provided that such rooms or areas are accessory to the area served. Foyers, lobbies, and reception rooms constructed as required for corridors shall not be construed as intervening rooms. Exit access shall be arranged so that it is not necessary to pass through any area identified under Protection from Hazards in Chapters 11 through 43.
Sect 7.12.1 Mechanical equipment rooms, boiler rooms, furnace rooms, and similar spaces shall be arranged to limit common path of travel to 100-feet in buildings protected throughout by an approved automatic sprinkler system in accordance with Section 9.7.
Sect 8.7.1.1(2) Protection from any area having a degree of hazard greater than that normal to the general occupancy of the building shall be provided by an automatic sprinkler system.
Sect 8.7.1.2 In new construction, where protection is provided with automatic extinguishing systems without fire-resistive separation, the space protected shall be enclosed with smoke partitions in accordance with Section 8.4.
Sect 9.7.4.1 Portable fire extinguishers shall be selected, installed, inspected, and maintained in accordance with NFPA 10, Standard for Portable Fire Extinguishers (2013).
NFPA 10
Sect 5.4.1.1 Building is classified as light (low) hazard occupancy.
Table 6.2.1.1 2-A minimum size
3,000 sq.ft. coverage per unit of A Maximum floor area for extinguisher: 11,250 sq.ft.
75-feet maximum travel distance.
Table 6.3.1.1 10-B minimum size 50-feet maximum travel distance
4-A:80-B:C portable fire extinguishers provided, with 50-feet maximum travel distance.
Sect 38.1.5 The contents of business occupancies shall be classified as ordinary hazard in accordance with Section 6.2.
Sect 38.1.7 The occupant load, in number of persons for whom means of egress and other provisions are required, shall be determined on the basis of the occupant load factors of Table 7.3.1.2 that are characteristic of the use of the space.
Sect 38.2.3.1 The capacity of means of egress shall be in accordance with Section 7.3.
Sect 38.2.3.2 The clear width of any corridor or passageway serving an occupant load of 50 or more shall be not less than 44-inches.
Sect 38.2.4.3 A single exit shall be permitted for a room or area with a total occupant load of less than
100 persons, provided that all of the following criteria are met:
(1) The exit shall discharge directly to the outside at the level of exit discharge for the building.
(2) The total distance of travel from any point, including travel within the exit, shall not exceed 100-feet.
Sect 38.2.5.2.1 In buildings protected throughout by an approved, supervised automatic sprinkler system in accordance with 9.7.1.1(1) [NFPA 13], dead-end corridors shall not exceed 50-feet.
Sect 38.2.5.3.1 Common path of travel shall not exceed 100-feet in a building protected throughout by an approved, supervised automatic sprinkler system in accordance with 9.7.1.1(1)
[NFPA13].
Sect 38.2.6.3 Travel distance shall not exceed 300-feet in business occupancies protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7
[NFPA 13].
Sect 38.3.2.1 Hazardous areas including, but not limited to, areas used for general storage, boiler or furnace rooms, and maintenance shops shall be protected in accordance with Section 8.7.
Sect 38.3.3.2.1 Interior wall and ceiling finish material complying with Section 10.2 shall be Class A or Class B in exits and in exit access corridors.
Sect 38.3.3.2.2 Interior wall and ceiling finishes shall be Class A, Class B, or Class C in areas other than those specified in 38.3.3.2.1.
Sect 38.3.5 Portable fire extinguishers shall be provided in every business occupancy in accordance with 9.7.4.1.
Sect 42.1.5.1 Contents of storage occupancies shall be classified as low hazard, ordinary hazard, or high hazard in accordance with Section 6.2, depending on the quantity and character of the materials stored, their packaging, and other factors.
Sect 42.1.7 The occupant load, in number of persons for whom means of egress and other provisions are required, shall be determined on the basis of the maximum probable population of the space under consideration.
Sect 42.2.3 The capacity of means of egress shall be in accordance with Section 7.3.
Sect 40.2.4.1. The number of means of egress shall comply with any of the following:
(1) In low hazard storage occupancies, a single means of egress shall be permitted from any story or section.
(2) In ordinary hazard storage occupancies, a single means of egress shall be permitted from any story or section, provided that the exit can be reached within the distance permitted as a common path of travel.
Table 42.2.5 In Low Hazard Storage Occupancies protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.1.1(1) [NFPA 13], there are no limits to dead-end corridors or common path of travel.
In Ordinary Hazard Storage Occupancies protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.1.1(1) [NFPA 13], dead-end corridors shall not exceed 100-feet and common path of travel shall not exceed 100-feet.
Table 42.2.6 In Low Hazard Storage Occupancies protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.1.1(1) [NFPA 13], there is no limit to maximum travel distance In Ordinary Hazard Storage Occupancies protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.1.1(1) [NFPA 13], maximum travel distance shall not exceed 400-feet.
2012 NFPA 1 Uniform Fire Code (Note: The following are direct or paraphrased sections from the aforementioned Code, unless indicated by italics) Sect 18.2.3.2.1 A fire department access road shall extend to within 50-feet of at least one exterior door that can be opened from the outside and that provides access to the interior of the building.
Sect 18.2.3.2.2 Fire department access roads shall be provided such that any portion of the facility or any portion of an exterior wall of the first story of the building is located not more than 150-feet from fire department access roads as measured by an approved route around the exterior of the building or facility.
Sect 18.2.3.2.2.1 When buildings are protected throughout with an approved automatic sprinkler system that is installed in accordance with NFPA 13, the distance in 18.2.3.2.2 shall be permitted to be increased to 450-feet.
Sect 18.2.3.4.1.1 Fire department access roads shall have an unobstructed width of not less than 20-feet.
Sect 18.2.3.4.2 Fire department access roads shall be designed and maintained to support the imposed loads of fire apparatus and shall be provided with an all-weather driving surface.
Sect 18.2.3.4.3.1 The turning radius of a fire department access road shall be as approved by the AHJ.
Sect 18.2.3.4.4 Dead-end fire department access roads in excess of 150-feet in length shall be provided with approved provisions for the fire apparatus to turn around.
L R
A
L R
A
L
A
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T
E D
B Y
P L O
T S
C A
L E
IS
S U
E D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF 67
T E
A M
F A
C
IL
IT
Y
B
F A
-1
-D
-0 -5
#2 A
P R
IL
A
P R
IL
A N
S I
D
Q J V
F -0
:1
R E
N O
V A
T E
W S
A A
L E
R T
F
IR
E
D E
S
A
P R
IL
T O
P O
G R
A P
H
IC
S U
R V
E Y
V-101
POWER RISER
POWER POLE AND GUY
LIGHT POLE
GRATE INLET
MANHOLE
GUARD POST
BUILDING OVERHANG
BUILDING
LEGEND
POWER PULL BOX
FIBER OPTICS PULL BOX
GAS METER
GUY POLE W/ LIGHTNING ROD
TRANSFORMER
STOP SIGN
A/C
OVERHEAD POWER
TELEPHONE
UNDERGROUND POWER
STORM SEWER
WATER
UTILITY NOTES
1. THIS DRAWING INCLUDES OBSERVED EVIDENCE OF SERVICES AND UTILITIES EVIDENT AT THE TIME OF
SURVEY ONLY. NO RESPONSIBILITY OR LIABILITY IS ASSUMED BY THE SURVEYOR FOR THE FAILURE TO SHOW
ANY BURIED SERVICE AND/OR UTILITY LINES EVEN THOUGH THEY MAY EXIST. CONTACT "ONE CALL"
(1-800-795-0555) PRIOR TO ANY EXCAVATION ON THIS SITE.
NOTES
HORIZONTAL CONTROL IS BASED ON UTM 14 COORDINATE SYSTEM SCALED BY THE COMBINED SCALE FACTOR
0.99988757 (GROUND TO GRID) AS PROVIDED BY NGS DATA SHEET FOR MONUMENT DH9585.
VERTICAL CONTROL IS BASED ON THE MINOT AIR FORCE BASE BENCH MARK, CP 102. ELEVATION 1625.29 NAVD 88, AS PROVIDED BY CHARLES STARNER
GUY WIRE
SATELLITE DISH
UNIDENTIFIED PULL BOX
UNIDENTIFIED VALVE
CONTROL POINT
RECORD GAS LINE
RECORD SANITARY
RECORD WATER LINE
RECORD COMMUNICATIONS LINE
V -1
T
O P
O G
R A
P H
IC
S
U R
V E
Y .D
W G
TOPOGRAPHIC SURVEY
TRUE
NORTH
N
SCALE: 1" = 20'-0" 20'10'0 40'
ASPHALT PAVEMENT
CONCRETE PAVEMENT
GRAVEL SURFACING
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T
E D
B Y
P L O
T S
C A
L E
IS
S U
E D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF 67
T E
A M
F A
C
IL
IT
Y
B
F A
-1
-D
-0 -5
#2 A
P R
IL
A
P R
IL
A N
S I
D
Q J V
F -0
:1
R E
N O
V A
T E
W S
A A
L E
R T
F
IR
E
D E
S
A
P R
IL
R E
M O
V A
L P
L A
N
CD101
LIMITS OF CONSTRUCTION
CONTRACTOR STAGING AREA
LEGEND
PAVEMENT REMOVAL
REMOVAL KEYNOTES:
R01. REMOVE CONCRETE WALL 2' BELOW FINAL GRADE.
R02. REMOVE BERM, SEE GRADING SHEET
R03. BID OPTION REMOVAL AND DISPOSAL OF THE ALASKA
BARRIERS
R04. RTES TOWER TO BE RELOCATED BY GOVERNMENT.
R05. REMOVE ROCK SURFACING
R06. REMOVE PAVEMENT, SAW CUT FULL DEPTH WHEN
ADJACENT PAVEMENT TO REMAIN.
R07. REMOVE LIGHTNING PROTECTION SYSTEM COORDINATE
WITH OTHER ELECTRICAL REMOVALS, SEE SHEET ED101.
C D
R
E M
O V
A L P
L A
N .D
W G
REMOVAL PLAN
TRUE
NORTH
N
SCALE: 1" = 20'-0"
20'10'0 40'
R02
R01
R07
R06
R06
R03
R07
R04
R06
R07
R03
R06
R07
R01
R06
R05
R05
R06
R06
1630.76
1630.95
1631.04
1631.04
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T
E D
B Y
P L O
T S
C A
L E
IS
S U
E D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF 67
T E
A M
F A
C
IL
IT
Y
B
F A
-1
-D
-0 -5
#2 A
P R
IL
A
P R
IL
A N
S I
D
Q J V
F -0
:1
R E
N O
V A
T E
W S
A A
L E
R T
F
IR
E
D E
S
A
P R
IL
A
L R
A
L
A
G R
A D
IN
G
A N
D E
R O
S
IO
N
C O
N T
R O
L
C-101
EXISTING CONTOUR
PROPOSED CONTOUR
LIMITS OF CONSTRUCTION
LEGEND
SEEDING SEE SPECIFICATION 32 92 19
NOTE:
EXCAVATED SOIL SHALL BE HAULED TO A LOCATION ON BASE AS DIRECTED BY THE
CONTRACTING OFFICER.
CONSTRUCTION ACCESS ROAD
CONTRACTOR STAGING AREA
GRADING KEYNOTES:
G01. CONSTRUCT INLET PROTECTION, PER CITY OF MINOT STANDARD DETAIL, ERO-6.
G02. INSTALL SILT FENCE, PER CITY OF MINOT STANDARD DETAIL, ERO-1
G03. CONSTRUCT CONSTRUCTION ENTRANCE, PER CITY OF MINOT STANDARD DETAIL, ERO-5.
MATCH EXISTING
SPOT ELEVATION (TOP OF SLAB)
C -1
G
R A
D
IN
G E
R O
S
IO
N C
O N
T R
O L .D
W G
SILT FENCE
GRADING AND EROSION CONTROL PLAN
TRUE
NORTH
N
SCALE: 1" = 20'-0"
20'10'0 40'
G02
G02
G02
G01
G01
G03
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T
E D
B Y
P L O
T S
C A
L E
IS
S U
E D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF 67
T E
A M
F A
C
IL
IT
Y
B
F A
-1
-D
-0 -5
#2 A
P R
IL
A
P R
IL
A N
S I
D
Q J V
F -0
:1
R E
N O
V A
T E
W S
A A
L E
R T
F
IR
E
D E
S
A
P R
IL
A
L R
A
L
A
U T
IL
IT
Y P
L A
N
C-102
LIMITS OF CONSTRUCTION
LEGEND
CONTRACTOR STAGING AREA
UTILITY KEYNOTES:
U01. TAP EXISTING 8" WATER MAIN
U02. CONSTRUCT 8" WATER MAIN FOR FIRE SERVICE WITH MINIMUM 9.0' OF COVER.
COORDINATE WORK WITH EXISTING UNDERGROUND COMMUNICATION LINES.
CLASSIFIED UTILITY LINES NOT SHOWN ON PLANS.
U03. CONNECT TO BUILDING FIRE SERVICE, VERIFY LOCATION ON FIRE SUPRESSION
PLANS
U04. CONSTRUCT POST INDICATOR VALVE, SEE DETAIL SHEET FX201.
U05. CONSTRUCT FIRE HYDRANT TEE, VALVE AND ASSEMBLY.
U06. CONSTRUCT 8" GATE VALVE
C -1
U
T
IL
IT
Y
P L A
N .D
W G
UTILITY PLAN
TRUE
NORTH
N
SCALE: 1" = 20'-0" 20'10'0 40'
SANITARY SEWER KEYNOTES:
S01. CONSTRUCT 54" I.D. MANHOLE OVER EXISTING 4" SANITARY SEWER WITH
EXTERNAL FRAME SEAL. ROTATE MANHOLE RIM TO BE EITHER ALL IN PROPOSED
SIDEWALK OR ALL OUT OF PROPOSED SIDEWALK.
RIM ELEV.= 1630.51
I.E.(6")(SW)(EXISTING)= 1620.95 (FIELD VERIFY)
I.E.(4")(NW)= 1620.95
I.E.(4")(NE)= 1620.95
S02. CONNECT TO BUILDING SANITARY SEWER SERVICE, VERIFY LOCATION ON
PLUMBING PLANS. I.E.(3")= 1628.14
S03. CONSTRUCT 4" SANITARY SEWER PIPE @ 2.00% WITH PIPE BEDDING.
S04. CONSTRUCT SANITARY SEWER CLEANOUT
RIM ELEV= 1630.52
I.E.(4")(NW)= 1622.00
I.E.(4")(NE)= 1622.00
S05. CONNECT TO BUILDING SANITARY SEWER SERVICE, VERIFY LOCATION ON
PLUMBING PLANS. I.E.(4")= 1628.14
U03
S04
S05
U02
S03
S01
S02
U04
U05
U06
U01
NOTE:
UTILITIES AT MINOT AFB ARE PRIVATIZED AND WILL REQUIRE THE CONTRACTOR TO
CONTACT THE FOLLOWING UTILITY PROVIDERS FOR PLACEMENT OF WATER AND
SANITARY SEWER UTILITIES. THE CONTRACTOR SHALL PAY ALL SERVICE INSTALLATION
FEES, CONNECTION FEES AND /OR UTILITY TAP-IN FEES ASSOCIATED WITH THE NEW
UTILITIES BEING INSTALLED ON THIS PROJECT.
A. WATER/SANITARY SEWER: CONTACT BASE UTILITIES AT (701) 727-5050
MR. RUSS GOHL FOR WATER AND SANITARY SEWER INSTALLATION.
BASE UTILITIES CONSTRUCTS ALL WATER AND SEWER MAINS AND
SERVICES TO 5 FEET FROM THE BUILDING AT THE CONTRACTOR'S
EXPENSE.
CONTRACTOR SHALL PATCH ALL ASPHALT/CONCRETE AFTER ALL
PRIVATIZED BASE UTILITIES HAVE BEEN INSTALLED.
14 15
28 29
R 10.00'
R10.00'
POINT TABLE
POINT #
NORTHING
17601363.52
17601368.32
17601352.86
17601351.65
17601317.13
17601312.33
17601289.58
17601286.38
17601280.40
17601271.54
17601289.13
17601292.68
17601294.41
17601316.55
17601318.13
17601322.00
17601323.58
17601325.29
17601335.17
17601321.36
17601316.88
17601349.13
EASTING
1079575.90
1079579.49
1079600.14
1079591.77
1079566.00
1079562.40
1079545.36
1079542.96
1079538.48
1079539.34
1079525.86
1079521.12
1079508.88
1079464.51
1079465.74
1079457.71
1079458.89
1079472.98
1079480.75
1079499.19
1079495.83
1079519.99
POINT TABLE
POINT #
NORTHING
17601362.42
17601379.94
17601386.61
17601382.64
17601398.60
17601397.80
17601394.93
17601398.13
17601400.42
17601400.93
17601403.82
17601400.61
17601406.96
17601416.08
17601417.63
17601422.57
17601420.95
17601361.05
17601357.26
17601299.61
EASTING
1079502.24
1079548.69
1079547.82
1079545.08
1079542.43
1079541.95
1079545.99
1079548.37
1079549.57
1079546.07
1079542.06
1079539.75
1079535.21
1079538.23
1079539.49
1079533.39
1079532.08
1079579.20
1079584.28
1079512.81
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T
E D
B Y
P L O
T S
C A
L E
IS
S U
E D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF 67
T E
A M
F A
C
IL
IT
Y
B
F A
-1
-D
-0 -5
#2 A
P R
IL
A
P R
IL
A N
S I
D
Q J V
F -0
:1
R E
N O
V A
T E
W S
A A
L E
R T
F
IR
E
D E
S
A
P R
IL
A
L R
A
L
A
P A
V
IN
G
P
A
N
C-103
LIMITS OF CONSTRUCTION
LEGEND
CONTRACTOR STAGING AREA
PAVING KEYNOTES:
P01 6" EGRESS PAVING, SEE DETAIL SHEET C-104. PART OF BID OPTION
FOR SECOND GARAGE DOOR, DRIVE & ASSOCIATED WORK.
P02. CONSTRUCT BOLLARD,SEE DETAIL SHEET C-104.
P03. CONSTRUCT HVAC EQUIPMENT SLAB, SEE M/E PLANS.
6" THICK PCC PAVING SECTION SEE DETAIL SHEET C-104
C -1
P
A V
IN
G
P L A
N .D
W G
PAVING PLAN
TRUE
NORTH
N
SCALE: 1" = 20'-0" 20'10'0 40'
5" THICK PCC SIDEWALK SEE DETAIL SHEET C-104
P02
P03
P02
P01
P02
JOINT PLAN
TRUE
NORTH
N
SCALE: 1" = 20'-0" 20'10'0 40'
X PANELS EQUALLY SPACED Y.YY FEET APART
DOWELED JOINT
X @ Y.YY'
CONTRACTION JOINT
1/2" EXPANSION JOINT
23.16'
2@ 11.58'
23.25'2@ 11.63'
.7
3'
2@
.8 7'
.0
0' 4@
.0
0'
.6
1'
P03
P02
3.80'
4.
3.
L
IC
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K A
P P
R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T
E D
B Y
P L O
T S
C A
L E
IS
S U
E D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T
N O
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF 67
T E
A M
F A
C
IL
IT
Y
B
F A
-1
-D
-0 -5
#2 A
P R
IL
A
P R
IL
A N
S I
D
Q J V
F -0
:1
R E
N O
V A
T E
W S
A A
L E
R T
F
IR
E
D E
S
A
P R
IL
A
L R
A
L
A
C
IV
IL
D
E T
A
IL
S
C-104
C -1
C
IV
IL
D E
T A
IL
S
.D W
G
TYPICAL BOLLARD
NO SCALE
6" THICK PCC PAVEMENT SECTION
NO SCALE
TYPICAL SIDEWALK SECTION
NO SCALE
FOUNDATIONS
F1. Subsoil investigations have not been made, therefore, the footings have been designed for the assumed bearing pressure below. If, during the course of excavation, any material or condition is encountered which might indicate a lower bearing pressure than assumed, the contractor shall notify the Contracting Officer.
F2. Bear footings on natural soils or suitable compacted fill materials. No footings shall be placed on frozen soils. All footings have been designed for an allowable net bearing pressure of 2,000 psf. This matches value listed on existing drawings.
F3. The Contractor shall locate and protect any existing utilities from damage or interruption during construction.
CONCRETE AND REINFORCEMENT
C1. Concrete work shall conform to all requirements of ACI 301, "Specifications for Structural Concrete for Buildings", except as modified by the Supplemental Requirements below.
C2. Submit a concrete mix design for each class of concrete for approval by the Project Engineer. The mix design shall include the proportions and test results or certifications for all components of the mix in accordance with the latest ACI 301.
Submit documented results of “field test data” or “trial mixtures” in accordance with ACI 301 for each class of concrete to be used. The mix designs shall meet the following guidelines except as approved by the Project Engineer.
C3. Design mixes to provide normal weight concrete with the following properties to be used in the locations specified:
28-day Comp. Cement per Water/ Air Strength cu. yd. Cement Content Slump Mix (min. psi) (min. pounds) (max. ratio) ( % ) ( inches )
A 4000 611 0.44 5-7 2-4 B 3000 517 0.50 5-7 2-4 C 3000 564 0.50 5-7 2-4 D 3000 658 -- -- 8-10
Air entrainment shall not be used for interior slabs.
C4. Mix Types 'C' and 'D' shall utilize sand-gravel fine aggregate only, maximum size = No. 4
C5. Use Type 'A' for exterior stoops, walks, exterior wall facing, and paving. Use Type 'D' for all masonry grouting and bond beam lintels. Use Type 'B' or Type 'C' for all other applications.
C6. All reinforcing steel shall be ASTM A 615 grade 60.
C7. Provide lap splices as indicated below unless noted otherwise in details and schedules. Top bars are horizontal bars with more than 12-inches of fresh concrete cast below the bars in question.
Splice Length Bar Size Top Bars All Other Bars
#3 1'-4" 1'-1" #4 1'-10" 1'-5" #5 2'-3" 1'-9" #6 2'-8" 2'-1"
C8. Concrete cover of reinforcement shall conform to ACI 318-02 unless detailed otherwise.
C9. Welded wire fabric shall be flat sheets and shall conform to ASTM A 1064.
C10. Vapor barrier shall be 10 mil polyethylene sheets unless otherwise specified, with all laps sealed and edges turned up 1/2 inches below finish floor slabs.
C11. Portland cement shall conform to ASTM C150, type I.
C12. Air-entraining admixtures shall conform to ASTM C260. Other admixtures, if used, shall conform to ASTM C494.
CONCRETE MASONRY
M1. Masonry units shall units shall be normal aggregate, hollow units and shall conform to ASTM C 90. Minimum compressive strength of individual units shall be 1900 PSI on the net area of the block. Design compressive strength of masonry, f'm = 1,500
PSI.
M2. Mortar shall conform to ASTM C 270 type S.
M3. Reinforce all masonry horizontally with galvanized 9 gage Durowal at 16 inches on center. Reinforce walls vertically as shown on the drawings. Lap splice vertical reinforcing as shown on the drawings.
STRUCTURAL STEEL
S1. All W-shape sections shall conform to ASTM A 992 (Fy = 50 ksi).
S2. All channels, angles, bars and plates shall conform to ASTM A 36 (Fy = 36 ksi).
S3. Tube sections shall conform to ASTM A 500 Grade B (Fy = 46 ksi).
S4. Bolts for structural connections shall be 3/4-inch diameter A325 in bearing-type connections, tightened to snug tight, unless noted otherwise. Snug tight is the tightness that exists when all plies in a joint are in firm contact, and may be achieved by a few impacts of an impact wrench or the full effort of a man using an ordinary spud wrench.
S5. Headed studs shall conform to ASTM A 108 complying with AWS Code.
S6. Welding shall be performed by certified welders using low hydrogen E70 electrodes. Comply with AWS for electrodes and procedures.
OPEN-WEB JOISTS
J1. Open web joists shall conform to SJI specifications.
J2. Roof joists shall be designed for a net uplift equal to 15 psf.
J3. Provide bridging and accessories per SJI. Install per manufacturer's shop drawings.
J4. Joists shall be prime painted.
METAL DECK
D1. Roof deck shall be 1 1/2-inch deep 22 gage wide-rib (Type B) metal deck conforming to SDI and ASTM A 1008 (painted), with a minimum yield strength of 33 ksi.
D2. Weld 1 ½” deep roof deck to supporting members at 6 inches on center at ALL supports, including edge supports along the side of the deck at the perimeter of the building, around openings, etc. Welds shall be 5/8-inch diameter plug welds. Fasten adjacent roof deck units at side laps using (2) #10 TEK screws per deck span, located at third points between supports.
D3. Galvanize all metal deck for stoops as per ASTM A 653, G60.
D4. Provide all necessary accessories including roof sump pans, column and end closures, etc.
D5. Provide 6-inch minimum wide, continuous cover plate of same thickness as decking where decking changes direction, or changes slope such as at valleys or ridges. Screw to deck along both sides at 12-inch centers maximum.
EXISTING CONSTRUCTION
EX1. Guard against movement or settlement of the existing structure. Provide bracing or shoring as necessary in connection therewith. Be responsible for safety and support of the structure during all phases of the construction.
EX2. If during the course of construction, movements or settlements of significant nature are observed, take precautions as necessary to secure the safety of the subject and/or adjoining premises, and contact the Contracting Officer.
EX3. The existing information shown on the drawings is as exact as could be secured insofar as building construction and existing conditions are concerned. Extreme accuracy is not guaranteed. The drawings and specification are intended for the assistance of the Contractor in achieving the end results. Many of the dimensions and conditions noted on the drawings are based on information obtained from the original drawings and may or may not be correct. Exact locations, measurements, distances, levels, etc. will be governed by conditions at the job site. The Contractor shall field verify all existing conditions and dimensions which affect work to be performed as part of this project, prior to any new construction or material fabrication.
This is the start of the file's text. The full file is on GovTribe.