Attachment 3 - Specifications 10-0045.pdf
PDF 2 MB Posted
- Attached to
- Roofing IDIQ Federal contract opportunity
- Solicitation number
- FA4528-09-R-0020
About this file
Attachment 3 - Specifications QJVF 10-0045
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA4528-09-R-0020 Amendment 02.doc | DOC document | |
| FA4528-09-R-0020 Amendment 01.doc | DOC document | |
| Attachment 6 - Specification Revision 10-0045 07565, 1-2.pdf | ||
| Attachment 6 - Seed Project Bid Schedule.xlsx | XLSX spreadsheet | |
| ATTACHMENT 4 RESPONSIBILITY.doc | DOC document | |
| Attachment 2A_Project Wage Determination_Roofer.doc | DOC document | |
| Attachment 5 Recent and Relevant Experience for LPTA | — | |
| Attachment 8 - Seed Project Drawing.doc | DOC document | |
| Attachment 7 - Seed Project Scope of Work.docx | DOCX document | |
| Attachment 1 10-0045 BID SCHEDULE.xlsx | XLSX spreadsheet | |
| Attachment 2_Davis Bacon Wage Determination_Effective 15 Aug 08.doc | DOC document | |
| SF 1442 Solicitation - FA4528-09-R-0020.doc | DOC document |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S P E C I F I C A T I O N
FOR PROJECT
QJVF 10-0045 REPAIR ROOFS - IDIQ
AT
MINOT AIR FORCE BASE, NORTH DAKOTA
PREPARED BY:
5 CES, ENGINEERING FLIGHT
MINOT AIR FORCE BASE, NORTH DAKOTA
FEB 2009
i
QJVF 10-0045
TABLE OF CONTENTS
DIVISION 1 - GENERAL REQUIREMENTS PAGES
01005 Statement of Work 01005-1, 2 01010 Administrative Provisions – Base Roofs 01010-1 thru 7 01300 Submittals 01300-1 thru 7
DIVISION 2 - SITEWORK
02072 Minor Demolition 02072-1 thru 4 ATTACHMENT Pages 4
DIVISIONS 3 THRU 4 - NOT USED
DIVISION 5 - METALS
05310 Metal Roof Deck 05310-1 thru 3 05500 Metal Fabrications 05500-1 thru 7
DIVISION 6 - WOOD AND PLASTIC
06100 Rough Carpentry 06100-1 thru 3
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
07240 Exterior insulation and Finish System 07240-1 thru 4 07300 Shingle Roofing System 07300-1 thru 5 07401 Long-Span Panel Steel Siding 07401-1 thru 4 07468 Aluminum Soffits, Fascia, and Gutter Systems 07468-1, 2 07510 Built-up Roofing 07510-1 thru 48 07560 EPDM Roofing System 07560-1 thru 21 07565 Rubber Roof Coating 07565-1, 2
DIVISIONS 8 THRU 9 - NOT USED
DIVISION 10 - SPECIALTIES
10420 Signage 10420-1, 2 ATTACHMENT Sign Template Page 1
DIVISION 11 THRU 14 - NOT USED
DIVISION 15 - MECHANICAL
15400 Plumbing 15400-1 thru 5
01005-1
DIVISION 1 - GENERAL REQUIREMENTS
SECTION 01005
STATEMENT OF WORK
1. GENERAL:
1.1 DESCRIPTION OF WORK: Work of this Contract, Repair Base Roofs - IDIQ, QJVF 10-0045, comprises maintenance and repair of various roofs located on Minot Air Force Base, North Dakota.
1.2 APPLICABLE PUBLICATIONS: All federal specifications, standards, and other publications shall be of the latest and most current issue at date of Invitation for Bids (IFB) issuance.
1.3 PROTECTION:
1.3.1 Roof Surfaces: Contractor shall protect all roof decking and installed roofing and hold them free from any damage due to his operations.
1.3.1.1 Roof loading of materials, planking, debris, equipment, etc., shall not exert a total concentrated loading in excess of 20 pounds per square foot on any part of the structure, at any one time.
1.3.1.2 Confine equipment, materials, storage and workmen's
movements and operation within limits required to perform specified work.
1.3.1.3 All materials, tools and appliances brought on roof
surfaces or stacked thereon shall be adequately supported on pallets, planks, or other approved systems.
1.3.1.4 Wheeled Conveyances: Temporary runways shall be
provided for all vehicular conveyances such as wheelbarrows, pallets, felt, etc.
1.3.1.5 Debris removed as a result of this work shall be
immediately loaded into an awaiting container, removed by means of an enclosed chute, hoist or bucket, and disposed of without again coming in contact with the roof surface.
1.3.2 Existing Facilities: Using agencies will occupy premises during entire period of repair for the conduct of normal operations.
Contractor shall monitor weather conditions and progress of work and be
01005-2 prepared to provide protection to occupied spaces below at the end of each day and during sudden changes in weather to prevent damage due to precipitation and/or wind.
1.3.3 Contractor shall provide protection and storage of all
materials to be incorporated into project work. No material shall be stored on roof structure except sufficient material required for each day's work accomplishment, when in compliance with roof loading restrictions.
END OF SECTION
01010-1
SECTION 01010
ADMINISTRATIVE PROVISIONS - BASE ROOFS
1.1 DESCRIPTION OF WORK: Work of this Contract, Repair Base Roofs - IDIQ, MIN 10-0045, comprises maintenance and repair of various types of roofs located at Minot Air Force Base, North Dakota, including all associated appurtenances, by methods inherent to type of defect, imperfection, or deterioration, thereby restoring waterproof/ weatherproof reliability.
1.2 UTILITY SERVICES AVAILABILITY: All reasonable quantities of water and electricity will be made available to the Contractor without cost.
1.3 CONDUCT: The Contractor shall conduct all work in an orderly manner with a minimum disturbance and inconvenience to normal operations of the Base.
1.4 SAFETY REQUIREMENTS: The Contractor shall comply with all applicable provisions of the Corps of Engineers Manual EM 385-1-1 entitled, "General Safety Requirements," and all OSHA, NEC, and Worker's Compensation requirements.
1.5 CONTRACTOR’S WORK HOURS: Working hours for the Contractor shall normally be between the hours of 7:30 a.m. and 4:00 p.m. excluding Saturdays, Sundays and paid federal holidays. If the Contractor desires to work during periods other than the above, additional Government inspection forces may be required. The Contractor must make his/her request to the Contracting Officer 3 days in advance of his/her intention to work during other periods to allow assignment of additional inspection forces. If such force is reasonably available, the Contracting Officer may authorize the Contractor to perform work during periods other than normal duty hours/days. However, if inspectors are required to perform in excess of their normal duty hours/days solely for the benefit of the Contractor, the actual cost of inspection at overtime rates will be charged to the Contractor. These adjustments to the Contract price may be made periodically as directed by the Contracting Officer.
1.5.1 Security Delays: The contractor shall include in his bid for security delay time for all contractor’s activity entering, or exiting a secure area. The contractor will assume, at his risk, 30 minutes time for access entry for a crew up to 6. Contractor shall notify the contracting officer or inspector verbally immediately following a delay.
01010-2
1.6 METHOD OF MEASUREMENT AND BASIS OF PAYMENT: The Contractor shall be paid based on the bid schedule for items in units shown. Measurement will be based on quantities used on bid schedule; square feet (SF), board feet (BF), square (Sq), lineal feet (LF), each (Ea) or roof. The unit bid prices shall include full compensation for furnishing labor, material, tools and equipment, and for performing work involved in this Contract.
1.6.1 Roof Investigation: Contractor shall provide with
government’s representative, a visual inspection of rht eoof to verify existing conditions and all existing measurements. Contractor shall come into agreement with government’s representative on all line items on bid schedule before any work can begin.
1.7 PROTECTION:
1.7.1 Existing Facilities: Using agencies will occupy premises during entire period of repair for the conduct of normal operations.
Contractor shall monitor weather conditions and progress of work and be prepared to provide protection to occupied spaces below at the end of each day and during sudden changes in weather to prevent damage due to precipitation and/or wind.
1.7.2 Contractor shall provide protection and storage of all
materials to be incorporated into project work. No material shall be stored on roof structure except sufficient material required for each day's work accomplishment, when in compliance with roof loading restrictions.
1.8 HAZARDOUS WASTE: Hazardous waste or other materials, as defined by the Resource Conservation and Recovery Act or Applicable Federal, State or local Regulations resulting from the Contractor's operations shall be removed, by the Contractor, off base on a daily basis and be disposed of IAW all applicable Federal and State Regulations.
1.9 DISMANTLING, DEMOLITION AND MATERIAL DISPOSITION:
1.9.1 Removal of Salvage: Contractor shall remove items to the extent required, with all removed materials and unsalvageable items hauled and disposed of off base. All materials salvaged for reuse shall receive prior approval of the Contracting Officer before reuse. Materials not acceptable for reuse shall be disposed of and replaced with new materials as hereinafter specified.
1.9.2 Sequence and method of operation shall be such that maximum practicable protection is provided for personnel, materials, equipment, aircraft and structures to minimize the spread of dust, flying particles, and intrusion of unfavorable weather at all times.
01010-3
1.10 CLEANUP: Contractor shall maintain site and roof area clean of all debris resulting from his work at all times. This shall include policing work area each day and removing any wind blown debris or materials from this area of operation. No materials or debris shall be permitted to be burned on the Base. All debris and unsalvageable waste materials shall become property of Contractor, and shall be removed and disposed of off Minot Air Force Base at the close of each day and prior to departure upon completion of a specific building, in an approved landfill for operation under North Dakota Solid Waste Management Regulation 23-29-01. Debris shall not be permitted to accumulate, unless deposited in an approved manner, and in a covered container. Gutters and downspouts shall be cleaned of all debris, and any other foreign material.
1.11 STORM-WATER REMOVAL: Contractor shall be responsible for removal of water in areas scheduled for daily work performance. Water removal shall be by pumping, siphoning, absorbent mopping, high-pressure air, brooming and/or combinations thereof or other approved methods that shall not cause any damage to applied roof systems, surrounding structures, landscape, etc. All storm water removal shall be in compliance with the Clean Water Act.
1.12 SNOW REMOVAL: Contractor shall be responsible for removal of all snow and ice on roof in areas scheduled for daily work performance.
Contractor shall dump snow and ice on ground at locations approved by Government representative. Care should be given by contractor not to damage landscaping, ground based equipment or block any sidewalks, driveways, roads or doors.
1.13 INSPECTING FOR ASBESTOS AND LEAD BASED PAINT (LBP): The “right to know” rules for LBP and asbestos are defined in the Occupational Health and Safety Administration (OSHA) 29 CFR 1910 and 1926. The Contractor will inspect the affected worksite for asbestos-containing materials and lead based paint where applicable. Typically, sampling roofing material is destructive and can lead to water damage of the roof and interior. The Contractor shall inspect the roofing material for asbestos (and LBP where applicable) no more than two weeks prior to start of work to minimize the potential for water damage.
1.13.1 Certification of Inspectors: The Contractor shall furnish a copy of the state issued asbestos (and LBP where applicable) inspector certifications prior to the inspection process. The inspectors will carry their state issued cards on their person during the inspection process.
1.13.2 Materials testing: Typically roofing materials are
classified as Category I non-friable, Presumed Asbestos Containing Materials (PACM) due to the difficulty of bulk sampling the material without interfering with the integrity of the roof itself. PACM roofing products include; built-up roofing, asphalt-containing single ply membrane systems, asphalt shingles, asphalt containing underlayment felts, asphalt-containing roof coatings and
01010-4 mastics, and asphalt-containing base flashings. PACM roofing products that use other bituminous or resinous binders (such as coal tars or pitches) are also considered to be Category I non-friable PACM.
1.13.3 Sample Analysis Summary Report: Each inspection shall be documented in an inspection report with lab results. The Contractor shall submit two paper copies and one electronic copy to the government.
1.14 HANDLING ASBESTOS CONTAINING ROOFING MATERIAL:
1.14.1 An ACM that is regulated under EPA NESHAPS is referred to as a Regulated Asbestos-Containing Material (RACM). RACM includes: friable ACM;
Category I non-friable ACM that has become friable; Category I non-friable ACM that has been or will be sanded, grounded, cut, or abraded; and Category II non-friable ACM that has already been or is likely to become crumbled, pulverized, or reduced to powder.
1.14.2 EPA NESHAPS does not cover roofing projects on single-family homes or on residential dwellings containing four or fewer units. Also, if the roofing project involves less than 160 square feet of RACM, NESHAPS does not apply regardless of the removal methods or material type. Notification of Demolition is always required under NESHAPS. However, EPA has determined that most roofing operations do not constitute a demolition but in fact a renovation activity and therefore, does not require a Notification unless 160 square feet of RACM roofing material is disturbed.
1.14.3 EPA has determined that when using a rotating blade (RB) roof cutter or other similar device that damages the roofing material, the removal of 5580 square feet of that material will create 160 square feet of RACM. For this interpretation, when using a knife, as, pry bar, etc., the action of “slicing” the roofing instead of cutting it (i.e. making it friable) is not governed under NESHAPS and therefore any amount or type of roofing material may be removed without falling under NESHAPS regulations.
1.14.4 OSHA considers certain roofing projects as Class II
operations. These include the removal of built-up roofing in which the roofing felts contain asbestos and the removal of asbestos-containing shingles. Other Class II operations may include the removal of asbestos-containing cement coatings, mastics, and flashings that are not intact or will not remain intact during the removal operation. If the coatings, mastics, and flashings can be removed intact “sliced” (I.e. not cut, sanded abraded, or pulverized) then they do not fall under OSHA Class II regulations.
1.14.5 Under OSHA, if the roofing operation is determined to be a Class II activity by a competent person (40 hour trained), certain work practices, personal protective equipment (PPE), and training are all required.
Training for Class II work on roofing systems requires, at a minimum, 8-hour
01010-5 specific training with at least one person trained as a competent person. The competent person does not necessarily have to be an employee of the roofing contractor. Removal procedures would include manual methods (no sanding, abrading or pulverizing). It must be lowered to the ground, not thrown off the roof, at the end of each work shift. Any material that is not deemed intact by the competent person shall be wrapped in plastic or placed in covered containers. RB roof cutters may be used for roofing but the blade(s) must be continually misted, unless the competent person determines that the wetting action may cause a slip or fall hazard. The debris from the cutting action must be collected either by HEPA vacuuming or placing in a covered container.
1.14.6 Personal exposure monitoring is also required if the roofing operation is determined to fall under Class II regulations. An alternative is to perform a negative exposure assessment in which personal air sampling is completed on the workers during the roofing removal activities in an effort to establish work practices that will not create airborne asbestos fiber concentrations at or above the OSHA permissible exposure limit (PEL) of 0.1 f/cc for 30 minutes. OSHA has determined that most Class II activities will not exceed the PEL when performed properly.
1.14.7 If the competent person determines that the roof operation can be performed intact, all the above stated requirements for Class II operations do not apply.
1.14.8 EPA maintains that if a roofing system is removed non-friable (left intact by slicing, prying, etc.) then the NESHAPS regulations do not apply. However, should a RB roof cutter be used or the roofing materials are determined to be non-intact, NESHAPS regulations would apply.
1.14.9 NESHAPS roofing regulations state that if a RB roof cutter is used, the blade(s) must be misted with water and all discharges from the cutter must be collected either by HEPA vacuuming or by placing in leak-tight impermeable containers. There are some exceptions to the wetting requirements such as if the water may damage the existing structure or equipment inside the structure or if wetting will present a safety hazard. All dust, debris, and material considered non-intact needs to be packaged in leak-tight impermeable containers and disposed of in an EPA approved landfill site. Roofing material that has been removed intact can be disposed of in any general refuse landfill- with their permission.
1.14.10 EPA states that for roof removals that are subject to NESHAP, at least one on-site supervisor trained in the provisions of NESHAP be present during the removal of the asbestos-containing roofing material. This onsite supervisor does not necessarily have to be an employee of the roofing contractor. If the roofing material is removed intact training under NESHAP is not required.
01010-6
1.15 NEW ROOFING MATERIALS: The Contractor shall not use new roofing material containing more than 1 percent asbestos. The Contractor shall provide material safety data sheets (MSDS) for all new roofing materials proving the materials contain less than 1 percent asbestos. New roofing materials with unknown asbestos content (especially coatings, cements, and mastics) are subject to EPA and OSHA asbestos regulations. Currently no ban on manufacturing with asbestos exists in the United States and asbestos can be found in new roofing materials.
1.16 HANDLING MATERIALS WITH LEAD BASED PAINT: Lead-Based Paint (LBP) activities must be performed in accordance with 40 CFR 745 and 29 CFR 1926.
1.17 ASBESTOS-CONTAINING ″TRANSITE″ SIDING: Some roofing material may be near or along the edge of asbestos-containing ″transite″ siding. The asbestos in this siding is fixed into the matrix of the siding material and is not friable unless disturbed. This transite siding is a Class II asbestos material and must be handled using Class II work practices.
1.17.1 The Contractor shall not disturb this material and make it friable. This includes using care with ladders and scaffolding. Heightened awareness while removing or placing roofing material near the transite siding will ensure the material is not scratched or otherwise damaged.
1.17.2 The Contractor will make all workers aware of the asbestos dangers inherent in this Class II material through their OSHA ″right to know″ training.
1.17.3 No other asbestos-containing materials have been identified with this work. However, if asbestos materials are encountered or even suspected, immediately stop work and notify the Contracting Officer.
1.18 RECYCLING/REUSE OF EXCESS MATERIALS AND CONSTRUCTION AND DEMOLITION
(C&D) DEBRIS: The Contractor shall reuse/recycle excess materials and Construction and Demolition (C&D) debris to the maximum extent possible.
C&D debris are those excess/residue materials resulting from construction or demolition activity that would normally be discarded to a landfill.
C&D debris includes, but is not limited to soil, rock, vegetation, concrete, asphalt, and building materials such as windows, wood, metal, and roofing materials. The Contractor shall recycle C&D debris resulting from demolition, which shall become the property of the Contractor unless specified otherwise or as determined by the Contracting Officer. Any existing material that is recycled and reused, its estimated quantity and weight shall be documented in a submittal for each delivery order.
1.18.1 Materials not to be returned to the Government and all Contractor-generated rubbish, if not recycled, shall be disposed of by the
01010-7
Contractor off site at his own expense, and in compliance with applicable environmental codes and regulations of governing authorities.
1.18.2 Reporting Tonnage of C&D Debris: Contractor shall track and report the tonnage of C&D Debris in two categories.
1.18.3 The C&D recycled/disposed tonnage report shall consist of a written memo with the tonnage of each category (recycled and disposed tonnage) submitted to 5 CES/CEVP through the Contracting Offices. Submit C&D recycled and disposed tonnage report when the project is completed.
1.19 NEW MATERIALS CONTAINING RECYCLED MATERIALS: All new materials that are used for the construction of the delivery order, its recycled quantities and weights shall be documented in a submittal for each delivery order.
01300-1
SECTION 01300
SUBMITTALS
1.1 PROCEDURES:
1.1.1 The Contractor shall be required to submit items listed in the Submittal Schedule at the end of this section.
1.1.2 Transmit each item under AF 3000, Material Approval Submittal form. Identify contract number, project number, and Contractor. Identify section and paragraph reference for each item submitted with the AF 3000.
Submit five (5) copies unless otherwise required elsewhere in the specification.
1.1.3 Unless specifically stated otherwise elsewhere in this
specification, each submittal shall be approved by the Contracting Officer prior to incorporation of materials into the work.
1.1.4 Contractor shall submit and have approved all required
submittals for each delivery order before any work on each delivery order can begin.
1.2 MANUFACTURER'S DATA AND SAMPLES: For the following types of submittals when a specific product of a specific manufacturer is identified (by catalog or product number, pattern, or style) and the Contractor does not desire to propose an alternate product as an equal, where an equal is allowed, a detailed submittal will not be required. The Contractor shall submit on an AF Form 3000 a list of submittals for which the specified products will be used. Submit in accordance with procedures identified in 1.1 above.
1.2.1 Product Data: Submit complete manufacturer's literature, which describes all salient characteristics identified as requirements in the specification. Literature, which is not specific to the proposed product, shall be marked to indicate clearly which item is being proposed for use in this contract.
1.2.2 Manufacturer's Certification: Submit a statement from the product manufacturer that proposed products meet the specified standards and other salient characteristics identified as requirements in the specification.
01300-2
1.3 TEST DATA: Test results shall be dated and signed by the agency performing the test.
1.4 WARRANTY: Submit detailed warranty information, which identifies specifically items covered as well as exclusions from the warranty and the warranty period. All copies shall be dated and signed by an authorized officer of the company. The officer's name and title shall be typed on the warranty adjacent to the signature.
1.5 MISCELLANEOUS SUBMITTALS: Submittals, which are none of the above types, shall meet the specific requirements identified in the referenced paragraph of the Specification Section identified in the schedule.
SC
H
ED
U
LE
O F
M A
TE
R
IA
LS
S U
B M
IT
TA
LS
P ro je ct N um be r P ro je ct T itl e:
S ol ic ita tio n/ C on tra ct N um be r
T O
B E
C O
M P
LE
TE
D B
Y P
R O
JE
C
T E
N G
IN
E
E R
N um be r o f C op ie s R eq ui re d
LINE NUMBER
IT
EM
O R
D
ES
C R
IP
TI
O N
O F
IT
EM
, C O
N
TR
AC
T
R
EF
ER
EN
C E, T
YP
E O
F
SU
B M
IT
TA
L
CERTIFICATION OF
COMPLIANCE
SHOP DRAWINGS
SAMPLES
COLOR SELECTION
MANUFACTURER'S
RECOMMENDATIONS
MANUFACTURER'S
WARRANTY
CATALOG DATA
OPERATING
INSTRUCTIONS
OTHER
REQUIRED
SUBMISSION DATE
DATE RECEIVED IN
CONTRACTING
DATE TO CIVIL
ENGINEERING
RETURN SUSPENSE
DATE
SUBMITTAL NUMBERS
D
AT
E C
O N
TR
AC
TO
R
N O
TI
FI
ED
CONTRACTOR
RESUBMITTAL
FINAL APPROVAL
R
EM
AR
K
S
AP
PR
O
VE
D D
IS
AP
PR
O
VE
D
SE
C
TI
O N
/1
.2 .1
C
R
TI
FI
C A
TI
O
N
SE
C
TI
O N
/1
.1 2.
AS
BE
ST
O S
R
EP
O R
T
SE
C
TI
O N
0/
TO
B
E C
O M
P
LE
TE
D
B Y
C O
N
TR
AC
T
AD
M
IN
IS
TR
AT
O R
Q
JV
F
-0
R ep ai r R oo fs
ID
IQ
SE
C
TI
O N
/1
.1 7.
&D T
O N
N
AG
E R
EP
O
SE
C
TI
O N
/1
.4
TI
FI
C
A
TI
O N
F O
R M
SE
C
TI
O N
PR
D
U C
T D
AT
A
SE
C
TI
O N
/1
EC
YC
LE
D
C O
N
TE
N T
SE
C
TI
O N
D
U C
T D
AT
A
SE
C
TI
O N
/1
.6
YC
LE
D
C O
N
TE
N T
SE
C
TI
O N
.5
W
AR
R
AN
TY
SE
C
TI
O N
/1
D
U C
T D
AT
A
SE
C
TI
O N
/1
M
U
AL
P
LA
N
01300-3
A F
Fo rm
ED
U
LE
O F
M A
TE
R
IA
LS
S U
B M
IT
TA
LS
P ro je ct N um be r P ro je ct T ic ita tio n/ C on tra ct N um
B E
C O
M P
LE
TE
D B
Y P
R O
JE
C
T E
N G
IN
E be r o f C op ie s R eq ui re d
LINE NUMBER
IT
EM
O R
D
ES
C R
IP
TI
O N
O F
IT
EM
, C O
N
TR
AC
T
R
EF
ER
EN
C E, T
YP
E O
F
SU
B M
IT
TA
L
CERTIFICATION OF
COMPLIANCE
SHOP DRAWINGS
SAMPLES
COLOR SELECTION
MANUFACTURER'S
RECOMMENDATIONS
MANUFACTURER'S
WARRANTY
CATALOG DATA
OPERATING
INSTRUCTIONS
OTHER
REQUIRED
SUBMISSION DATE
DATE RECEIVED IN
CONTRACTING
DATE TO CIVIL
ENGINEERING
RETURN SUSPENSE
DATE
SUBMITTAL NUMBERS
D
AT
E C
O N
TR
AC
TO
R
N O
TI
FI
ED
CONTRACTOR
RESUBMITTAL
FINAL APPROVAL
R
EM
AR
K
S
AP
PR
O
VE
D D
IS
AP
PR
O
VE
D
TO
B
E C
O M
P
LE
TE
D
B Y
C O
N
TR
AC
T
AD
M
IN
IS
TR
AT
O R
Q
JV
F
-0
R ep ai r R oo fs
ID
IQ
SE
C
TI
O N
/1
.3
YC
LE
D
C O
N
TE
N T
SE
C
TI
O N
SU
BM
IT
TA
LS
SE
C
TI
O N
0/
SE
C
TI
O N
/1
YC
LE
D
C O
N
TE
N T
SE
C
TI
O N
/1
SA
PL
ES
C
TI
O N
/1
D
U C
T D
AT
A
SE
C
TI
O N
/1
R
AN
TY
SE
C
TI
O N
/1
PL
V
IE
W
(P
ER
D .O
SE
C
TI
O N
/1
-B U
IL
T
D R
AW
IN
G (P
ER
D
.O
SE
C
TI
O N
/1
SD
S
D
AT
A
SH
EE
TS
SE
C
TI
O N
/1
.7
YC
LE
D
C O
N
TE
N T
SE
C
TI
O N
IT
TA
LS
01300-4
A F
Fo rm
ED
U
LE
O F
M A
TE
R
IA
LS
S U
B M
IT
TA
LS
P ro je ct N um be r P ro je ct T ic ita tio n/ C on tra ct N um
B E
C O
M P
LE
TE
D B
Y P
R O
JE
C
T E
N G
IN
E be r o f C op ie s R eq ui re d
LINE NUMBER
IT
EM
O R
D
ES
C R
IP
TI
O N
O F
IT
EM
, C O
N
TR
AC
T
R
EF
ER
EN
C E, T
YP
E O
F
SU
B M
IT
TA
L
CERTIFICATION OF
COMPLIANCE
SHOP DRAWINGS
SAMPLES
COLOR SELECTION
MANUFACTURER'S
RECOMMENDATIONS
MANUFACTURER'S
WARRANTY
CATALOG DATA
OPERATING
INSTRUCTIONS
OTHER
REQUIRED
SUBMISSION DATE
DATE RECEIVED IN
CONTRACTING
DATE TO CIVIL
ENGINEERING
RETURN SUSPENSE
DATE
SUBMITTAL NUMBERS
D
AT
E C
O N
TR
AC
TO
R
N O
TI
FI
ED
CONTRACTOR
RESUBMITTAL
FINAL APPROVAL
R
EM
AR
K
S
AP
PR
O
VE
D D
IS
AP
PR
O
VE
D
TO
B
E C
O M
P
LE
TE
D
B Y
C O
N
TR
AC
T
AD
M
IN
IS
TR
AT
O R
Q
JV
F
-0
R ep ai r R oo fs
ID
IQ
SE
C
TI
O N
/1
YC
LE
D C
O N
TE
N
T
SE
C
TI
O N
/1
SA
PL
ES
C O
LO
R
SE
C
TI
O N
/1
P
O
D U
C T
A N
D
IN
S
TA
LL
A
TI
O
N
PR
O D
U C
T
AN
D
IN
ST
AL
LA
TI
D
A
SE
C
TI
O N
/1
R
AN
TY
SE
C
TI
O N
/1
S
D
AT
A
SH
EE
TS
SE
C
TI
O N
/1
YC
LE
D
C O
N
TE
N T
SE
C
TI
O N
/1
U
FA
C
TU
R
ER
'S
R
TI
FI
C A
TI
O
N
SE
C
TI
O N
/1
Q U
A
LI
TY
C
O N
TR
O
L D
ES
IG
N
AT
E
SE
C
TI
O N
/1
D U
C T
D
AT
A
SE
C
TI
O N
/1
U
AL
P
LA
N
SE
C
TI
O N
/1
R
AN
TY
01300-5
A F
Fo rm
ED
U
LE
O F
M A
TE
R
IA
LS
S U
B M
IT
TA
LS
P ro je ct N um be r P ro je ct T ic ita tio n/ C on tra ct N um
B E
C O
M P
LE
TE
D B
Y P
R O
JE
C
T E
N G
IN
E be r o f C op ie s R eq ui re d
LINE NUMBER
IT
EM
O R
D
ES
C R
IP
TI
O N
O F
IT
EM
, C O
N
TR
AC
T
R
EF
ER
EN
C E, T
YP
E O
F
SU
B M
IT
TA
L
CERTIFICATION OF
COMPLIANCE
SHOP DRAWINGS
SAMPLES
COLOR SELECTION
MANUFACTURER'S
RECOMMENDATIONS
MANUFACTURER'S
WARRANTY
CATALOG DATA
OPERATING
INSTRUCTIONS
OTHER
REQUIRED
SUBMISSION DATE
DATE RECEIVED IN
CONTRACTING
DATE TO CIVIL
ENGINEERING
RETURN SUSPENSE
DATE
SUBMITTAL NUMBERS
D
AT
E C
O N
TR
AC
TO
R
N O
TI
FI
ED
CONTRACTOR
RESUBMITTAL
FINAL APPROVAL
R
EM
AR
K
S
AP
PR
O
VE
D D
IS
AP
PR
O
VE
D
TO
B
E C
O M
P
LE
TE
D
B Y
C O
N
TR
AC
T
AD
M
IN
IS
TR
AT
O R
Q
JV
F
-0
R ep ai r R oo fs
ID
IQ
SE
C
TI
O N
/1
S
D
AT
A
SH
EE
TS
SE
C
TI
O N
/1
YC
LE
D
C O
N
TE
N T
SE
C
TI
O
N
0/
SE
C
TI
O N
/1
.5 .8
A
LI
TY
C O
N
TR
O L
R E
C O
R D
SE
C
TI
O N
/1
.5
O F
PL
AN
SE
C
TI
O N
/1
.5
-B
U
IL
T R
O O
F
SU
M M
AR
Y
SE
C
TI
O N
/4
A
LI
TY
C O
N
TR
O L
SE
C
TI
O N
/1
FO
M A
-3
SE
C
TI
O N
/1
FO
M C
SE
C
TI
O N
/1
.7
O
FI
N G
S
YS
TE
C
TI
O N
/1
.7
AL
AN
T
SE
C
TI
O N
/1
SH
P D
R
AW
IN
G
S
01300-6
A F
Fo rm
ED
U
LE
O F
M A
TE
R
IA
LS
S U
B M
IT
TA
LS
P ro je ct N um be r P ro je ct T ic ita tio n/ C on tra ct N um
B E
C O
M P
LE
TE
D B
Y P
R O
JE
C
T E
N G
IN
E be r o f C op ie s R eq ui re d
LINE NUMBER
IT
EM
O R
D
ES
C R
IP
TI
O N
O F
IT
EM
, C O
N
TR
AC
T
R
EF
ER
EN
C E, T
YP
E O
F
SU
B M
IT
TA
L
CERTIFICATION OF
COMPLIANCE
SHOP DRAWINGS
SAMPLES
COLOR SELECTION
MANUFACTURER'S
RECOMMENDATIONS
MANUFACTURER'S
WARRANTY
CATALOG DATA
OPERATING
INSTRUCTIONS
OTHER
REQUIRED
SUBMISSION DATE
DATE RECEIVED IN
CONTRACTING
DATE TO CIVIL
ENGINEERING
RETURN SUSPENSE
DATE
SUBMITTAL NUMBERS
D
AT
E C
O N
TR
AC
TO
R
N O
TI
FI
ED
CONTRACTOR
RESUBMITTAL
FINAL APPROVAL
R
EM
AR
K
S
AP
PR
O
VE
D D
IS
AP
PR
O
VE
D
TO
B
E C
O M
P
LE
TE
D
B Y
C O
N
TR
AC
T
AD
M
IN
IS
TR
AT
O R
Q
JV
F
-0
R ep ai r R oo fs
ID
IQ
SE
C
TI
O N
/1
R
AN
TY
SE
C
TI
O N
/1
U
AL
P
LA
N
SE
C
TI
O N
/1
M
SD
S
D
AT
A
SH
EE
TS
SE
C
TI
O N
/1
YC
LE
D
C O
N
TE
N T
SE
C
TI
O N
/1
.9
O R
D D
O C
U M
EN
T
SE
C
TI
O N
/3
A
LI
TY
C
O N
TR
O
L
SE
C
TI
O N
/1
D
U C
T D
AT
A
SE
C
TI
O N
/1
S
D
AT
A
SH
EE
TS
SE
C
TI
O N
/1
YC
LE
D
C O
N
TE
N T
SE
C
TI
O N
/1
IN
TA
LL
A
TI
O
N
IN
S
TR
U C
TI
O
N S
SE
C
TI
O N
/1
R
AN
TY
01300-7
A F
Fo rm
ED
U
LE
O F
M A
TE
R
IA
LS
S U
B M
IT
TA
LS
P ro je ct N um be r P ro je ct T ic ita tio n/ C on tra ct N um
B E
C O
M P
LE
TE
D B
Y P
R O
JE
C
T E
N G
IN
E be r o f C op ie s R eq ui re d
LINE NUMBER
IT
EM
O R
D
ES
C R
IP
TI
O N
O F
IT
EM
, C O
N
TR
AC
T
R
EF
ER
EN
C E, T
YP
E O
F
SU
B M
IT
TA
L
CERTIFICATION OF
COMPLIANCE
SHOP DRAWINGS
SAMPLES
COLOR SELECTION
MANUFACTURER'S
RECOMMENDATIONS
MANUFACTURER'S
WARRANTY
CATALOG DATA
OPERATING
INSTRUCTIONS
OTHER
REQUIRED
SUBMISSION DATE
DATE RECEIVED IN
CONTRACTING
DATE TO CIVIL
ENGINEERING
RETURN SUSPENSE
DATE
SUBMITTAL NUMBERS
D
AT
E C
O N
TR
AC
TO
R
N O
TI
FI
ED
CONTRACTOR
RESUBMITTAL
FINAL APPROVAL
R
EM
AR
K
S
AP
PR
O
VE
D D
IS
AP
PR
O
VE
D
TO
B
E C
O M
P
LE
TE
D
B Y
C O
N
TR
AC
T
AD
M
IN
IS
TR
AT
O R
Q
JV
F
-0
R ep ai r R oo fs
ID
IQ
SE
C
TI
O N
IT
TA
LS
SE
C
TI
O N
/1
YC
LE
D
C O
N
TE
N T
SE
C
TI
O N
0/
SE
C
TI
O
N
D
U C
T D
A
SE
C
TI
O N
/1
YC
LE
D C
O N
TE
N
T
01300-8
END OF SECTION
A F
Fo rm
02072-1
DIVISION 2 - SITEWORK
SECTION 02072
MINOR DEMOLITION FOR REMODELING
1.1 WORK INCLUDED:
1.1.1 Notify the North Dakota Department of Health using form SFN 17987, Notification of Demolition and Renovation. (See Attachment at end of this section.)
1.1.2 Remove designated roofing systems.
1.1.3 Remove designated metal fascia, flashings, gutters, downspouts, etc. and all accessories.
1.1.4 Remove designated curbs, steel framing and cut all required welds.
1.1.5 Remove designated siding system material.
1.1.6 Cap and identify exposed utilities.
1.1.7 Provide temporary partitions to allow continued building occupancy.
1.1.8 All material resulting from demolition work, except as
indicated or specified otherwise, shall become the property of the Contractor and shall be removed from the limits of Minot AFB.
1.1.9 Work shall include furnishing all necessary labor, materials, tools, and equipment necessary to demolish work specified and/or indicated on the drawings and spelled out in delivery order.
1.2 RELATED WORK:
1.2.1 Section 01010: Administrative provisions - Base Roofs.
1.2.2 Section 05310: Metal roof deck.
1.2.3 Section 05500: Metal fabrication.
1.2.4 Section 06100: Rough carpentry.
02072-2
1.2.5 Section 07240: Exterior Insulation and finish system.
1.2.6 Section 07300: Shingle roofing system.
1.2.7 Section 07401: Long-span panel steel siding.
1.2.8 Section 07468: Aluminum soffits, fascia and gutter systems.
1.2.9 Section 07510: Built-up roofing.
1.2.10 Section 07560: EPDM roofing systsm.
1.2.11 Section 07565: Rubber roof coating.
1.2.12 Section 15400: Plumbing.
1.3 PROTECTION:
1.3.1 Do not interfere with use of adjacent rooms and spaces.
Maintain free and safe passage to and from.
1.3.2 Prevent movement or settlement of structure(s). Provide and place bracing or shoring and be responsible for safety and support of structure. Assume liability for such movement, settlement, damage or injury.
1.3.3 Cease operations and notify the Contracting Officer
immediately if safety of structure appears to be endangered. Take precautions to properly support structure. Do not resume operations until safety is restored.
1.3.4 Provide, erect, and maintain barricades, lighting, and guard rails as required to protect occupants of building and workers.
1.4 SUBMITTALS:
1.4.1 Submit a copy of the North Dakota Department of Health form SFN 17987 that was submitted to state in accordance with Section 01300.
2. PRODUCTS:
2.1 MATERIALS:
2.1.1 Except where noted otherwise, maintain possession of materials being demolished. Immediately remove from site.
02072-3
3. EXECUTION:
3.1 PREPARATION:
3.1.1 Erect and maintain dustproof partitions as required to prevent spread of dust, fumes and smoke to other parts of the building. On completion, remove partitions and repair damaged surfaces to match adjacent surfaces.
3.1.2 Carry out demolition work to cause as little inconvenience to adjacent occupied building areas as possible.
3.1.3 Install fencing around openings to protect workers. Post clearly visible warning signs.
3.2 DEMOLITION:
3.2.1 Demolish in an orderly and careful manner as required to accommodate new work.
3.2.2 Perform demolition in accordance with applicable authorities having jurisdiction.
3.2.3 Repair all demolition performed in excess of that required, at no cost to the Air Force.
3.2.4 Burning of materials on site is not permitted.
3.2.5 Remove from site contaminated, vermin infested or dangerous materials encountered and dispose of by safe means so as not to endanger health of workers and public.
3.2.6 Remove demolished materials, tools and equipment from site upon completion of work.
3.3 DEBRIS CONTROL:
3.3.1 Extreme care will be taken when transporting debris. The Contractor will be responsible for sweeping and maintaining any and all base roads used as haul routes during construction. Debris shall be removed and transported by the Contractor in a manner as to prevent spillage on streets or adjacent areas.
02072-4
3.3.2 Regulations: Minot AFB and North Dakota state regulations regarding hauling and disposal shall apply.
3.4 USE OF EXPLOSIVES: Use of explosives will not be permitted.
05310-1
DIVISION 5 - METALS
SECTION 05310
METAL ROOF DECK
1.1.1 Steel roof deck and accessories.
1.1.2 Steel framed openings.
1.1.3 Bearing plates and angles.
1.2 REFERENCES:
1.2.1 AISI - Specification for the Design of Cold-Formed Steel Structural Members.
1.2.2 ASTM A36 - Structural Steel.
1.2.3 ASTM A325 - High strength bolts for structural steel joints.
1.2.4 ASTM A446 - Steel Sheet, Zinc-Coated (Galvanized) by the Hot- Dip Process, Structural (Physical) Quality.
1.2.5 ASTM A490 - Quenched and tempered alloy steel bolts for structural steel joints.
1.2.6 ASTM A525 - Steel Sheet, Zinc-Coated, Galvanized by the Hot- Dip Process.
1.2.7 ASTM A611 - Steel, Cold-Rolled Sheet, Carbon, Structural.
1.2.8 AISC - Specification for the design, fabrication and erection of structural steel for buildings.
1.2.9 AWS D1.1 - Structural Welding Code.
1.2.10 SDI - Design Manual for Composite Decks, Form Decks, Roof Decks.
1.3 DELIVERY, STORAGE AND HANDLING:
05310-2
1.3.1 Store decking and steel on wood sleepers with slope for positive drainage.
1.4 SUBMITTALS:
1.4.1 Submit shop drawings and product data in accordance with Section 01300.
1.4.2 Recycled Content: Submit data for all used and new materials that indicates quantity and weight of all recycled materials that are used in each delivery order.
1.5 RELATED WORK:
1.5.1 Section 07510 - Built-up Roofing
1.5.2 Section 07560 - EPDM Roofing System
2. PRODUCTS:
2.1 MATERIALS:
2.1.1 Sheet Steel: ASTM A446, Grade A structural quality; with G90 coating primed.
2.1.2 Bearing Plates or Angles: ASTM A36 steel.
2.1.3 Bolts, nuts and washers: ASTM A325.
2.1.4 Welding Materials: AWS D1.1.
2.1.5 Cell Closures: Closed cell foam rubber, one inch thick, profiled to decking.
2.1.6 Metal Closure Strips, Wet Concrete Stops, Cover Plates, and Related Accessories: 20 gage sheet steel; of required profiles and size.
2.1.7 Primer: Red oxide type.
2.1.8 Touch-up Primer: To match deck finish.
2.2 FABRICATION:
2.2.1 Metal Decking: Minimum 22 gage sheet steel, 1 1/2 inch high, Type "A" fluted profile to SDI 36 inches wide sheets; multiple span; lapped joints.
05310-3
2.2.2 Fabricate metal decking in accordance with SDI Design Manual for Composite Decks, Form Decks, Roof Decks to accommodate maximum working stress of 20,000 psi and maximum span deflection of 1/240.
3. EXECUTION:
3.1 INSTALLATION:
3.1.1 Erect metal decking in accordance with SDI Design Manual for Composite Decks, Form Decks, Roof Decks. Provide welding in accordance with
AWS D1.1.
3.1.2 On steel support members provide 3 inch minimum bearing.
Align and level on supports.
3.1.3 On masonry support surfaces provide 4 inch minimum bearing.
Align and level on supports.
3.1.4 Mechanically fasten male/female side laps at 24 inches o/c maximum or weld male/female side lap at 18 inches o/c maximum.
3.1.5 Fasten deck to steel support members at ends and intermediate supports with 3/4 inch fusing welds at 12 inches o/c maximum.
3.1.6 Install steel closures and angle flashings to close openings between deck and walls, columns and openings.
3.1.7 Install foam cell closures in locations above walls and partitions.
3.1.8 Immediately after welding deck in place, touch-up welds, burned areas and surface coating damage with prime paint.
05500-1
DIVISION 5 - METALS
SECTION 05500
METAL FABRICATIONS
1.1.1 Shop fabricated ferrous metal items.
1.1.1.1 Fascia
1.1.1.2 Soffits
1.1.1.3 Fabricated Gutter
1.1.1.4 Fabricated Downspouts
1.1.1.5 Flashing and Caps
1.1.1.6 Scuppers
1.1.1.7 Miscellaneous Metal
1.1.1.8 Accessory Components
1.1.1.9 Snow Guards
1.2 RELATED WORK:
1.2.1 Section 05310 - Metal Roof Deck
1.2.2 Section 06100 - Rough Carpentry
1.2.3 Section 07300 - Shingle Roofing System
1.2.4 Section 07510 – Built-up Roofing
1.2.5 Section 07560 – EPDM Roofing System
05500-2
1.3 REFERENCES:
1.3.1 ANSI/ASTM A153 - Zinc Coating (Hot-Dip) on Iron and Steel Hardware.
1.3.2 ANSI/ASTM A167 - Stainless and Heat Resisting Chromium-Nickel Steel Plate, Sheet and Strip.
1.3.3 ANSI/ASTM A446 - Steel Sheet, Zinc Coated (Galvanized) by the Hot Dip Process, Structural (Physical) Quality.
1.3.4 ASTM B209 - Aluminum and Aluminum-Alloy Sheet and Plate.
1.3.5 ASTM E84 - Surface Burning Characteristics of Building
Materials.
1.3.6 Factory Mutual Global Manual 1-49-perimeter flashing.
1.3.7 SMACNA (Sheet Metal and Air Conditioning Contractor’s National Association)-Architectural Sheet Metal Manual.
1.3.8 ASTM A36 – Structural Steel.
1.3.9 ASTM A325 – High Strength Bolts for Structural Steel Joints.
1.3.10 ASTM A490 – Quenched and Tempered Alloy Steel Bolts for Structural Steel Joints.
1.3.11 ASTM A500 – Cold-Formed Welded and Sealess Carbon Steel Structural Tubing.
1.3.12 ASTM A501 – Hot-Formed Welded and Seamless Carbon Steel Structural Tubing.
1.3.13 ASTM A502 – Steel Structural Rivets.
1.3.14 ASTM A572 – High Strength Low Alloy Columbium-Vanadium Steel of Structural Quality.
1.3.15 AWS D1.1 – Structural Welding Code.
1.3.16 AISC – Specification for the Design, Fabrication and Erection of Structural Steel for Buildings.
1.3.17 FS TT-P-31 – Paint, Oil: Iron Oxide, Ready Mix, Red and Brown.
05500-3
1.4 SUBMITTALS:
1.4.1 Submit shop drawings and product data in accordance with Section 01300.
1.4.2 Indicate dimensions, panel layout, construction details, method of anchorage, method and sequence of installation.
1.4.3 Submit manufacturer's color samples in accordance with
Section 01300.
1.4.4 Submit manufacturer's installation instructions in accordance with Section 01300.
1.4.5 Submit Product Data, Installation Instructions and
Color/Finishes for Snow Guards, in accordance with Section 01300.
1.4.6 Recycled Content: Submit data for all used and new materials that indicate quantity and weight of all recycled materials that are used in each delivery order.
1.5 WARRANTY:
1.5.1 Finish:
1.5.1.1 Written 20-year non-prorated warranty covering fade, chalking and film integrity.
1.5.1.2 The warranty shall include labor and materials
through the 20th year.
1.5.1.3 The material shall be warranted not to show a color
change greater than five NBS color units per ASTM D 2244-79.
1.5.1.4 The finish shall not show chalking in excess of eight per ASTM D 659-80.
1.5.2 Installation:
1.5.2.1 Written by the installer, a 5-year non-prorated
warranty for water tightness of the installed system.
2. PRODUCTS:
05500-4
2.1 SHEET METAL:
2.1.1 General:
2.1.1.1 All materials shall be 24-gauge, hot-dipped
galvanized steel (G-90) commercial quality, extra smooth primed and finished one side with Kynar based fluoropolymer coating 1.0 ± 0.1 mil total dry film thickness.
2.1.1.2 A wash coat of .3 to .4 mil dry film thickness shall
be applied to the reverse side.
2.1.1.3 Lead: Manufactured from a base metal conforming to
FSQQ-L-171E Lead Pig, Grades A or C or ASTM B29 Pig Lead, chemical lead type modified as follows: Hard lead containing 4 to 6 percent antimony, and the remainder lead or hard lead containing 3.75 to 4.75 percent antimony, 0.07 to
0.10 percent arsenic.
2.1.1.4 Solder, Flux and Accessories: As necessary and
compatible with the material being installed.
2.1.2 Performance Criteria:
2.1.2.1 The finish coating shall conform to the following
tests and standards.
2.1.2.1.1 Hardness - F Minimum NCCA Technical
Bulletin 11-12.
2.1.2.1.2 Adhesion, Cross Hatch - 1/16 inch (no
removal): NCCA Technical Bulletin 11-5.
2.1.2.1.3 Formability, 2T Bend (no cracking or
removal): ASTM D 522-60 (1973).
2.1.2.1.4 Reverse Impact; no removal when tapped:
NCCA Technical Bulletin 11-6 (impact force - 70 in. - lbs.).
2.1.2.2 The base metal shall conform to the following test
and standards:
2.1.2.2.1 Minimum Yield: 33,000 psi ASTM 370-77.
2.1.2.2.2 Thermal Expansion - 6.7 x 106 in/in/F
degrees; ASTM E 228-71 (1979).
05500-5
2.1.2.2.3 Modulus of Elasticity - 29 x 106;
ASTM E 111-61 (1978).
2.1.3 Panel Color: Panel shall be dark bronze, Federal Standard #X0040, or match existing.
2.2 SEALANTS AND GASKETS: Type suitable for use with installation of metal.
2.3 OTHER MATERIALS: Provide all other materials, not specifically described, but required to construct a complete watertight installation.
2.4 SCUPPERS: Minimum 12” wide x 6” Out.
2.5 SNOW GUARDS: Snow guards shall be the standard product of a manufacturer who has been in the practice of manufacturing snow guard systems for a period of not less than 3 years. The system shall consist:
2.5.1 Approved Manufacturers: Dynamic Fastener, or approved equal.
2.5.2 Extruded Aluminum Clamps: S-5-U Clamps with stainless steel set screws and washers. Clamps shall be 6061-T6 aluminum conforming to ASTM B221. Set screws shall be 300 series stainless, 18-8 alloy, with round nose point. Set screws shall not penetrate roof seams or panels; nor void roof warranty. Space clamps as per manufacturer’s requirements.
2.5.3 Extruded Aluminum Cross Members: S-5 Snow Guards. Snow
Guards shall be 6061-T6 alloy and temper aluminum extrusions conforming to ASTM B221 and AA aluminum standards and data. Receptacle in face to receive color-matched metal strips. Provide splice connectors ensuring alignment and structural continuity at end joints.
2.5.3.1 Color Strip: Include same material and finish as
roof panels.
2.5.3.2 Snow and Ice Clips: Extruded aluminum with rubber
foot, minimum three (3) inches wide. Install one (1) snow and ice clip on all roof panels 12” or less, center in panel. Install two (2) snow and ice clips on all roof panels over 12” wide, equal space. Verify height.
2.5.4 Accessories: All other additional fasteners, brackets, accessories, etc., shall be made of the same material and manufacturer for a complete system.
2.6 STRUCTURAL STEEL:
2.6.1 Structural Steel Members: ASTM A36.
2.6.2 Structural Tubing: ASTM A500, Grade B.
05500-6
2.6.3 Bolts, Nuts and Washers: ASTM A325.
2.6.4 Welding Materials: AWS D1.1; type required for materials being welded. E70 Electrodes.
2.6.5 Primer: FS 55-P-31, red.
2.7 FABRICATION:
2.7.1 Fabricate structural steel members in accordance with AISC Specification.
2.8 FINISH:
2.8.1 Clean, prepare and shop prime structural steel members. Do not prime surfaces to be field welded or in contact with concrete.
3. EXECUTION:
3.1 FABRICATION:
3.1.1 Form angles for a watertight installation.
3.1.2 Soffits to be fabricated to match roof panels and existing soffits.
3.1.3 Gutters, corners, downspouts, and trim to be of the same material as panels. Fabricate to required shapes.
3.1.4 Miter internal corners, back brace with solid sheeting.
3.1.5 Expansion Joints: Same material and finish as panels.
3.1.6 Form joints to allow for expansion.
3.2 ERECTION:
3.2.1 Install underlayment.
3.2.2 Permanently install panels to structure; align, level and plumb.
3.2.3 Coordinate caps and flashing with elastomeric sheet roofing.
Seal to prevent weather penetration.
3.2.4 Fabricate and install metal as shown on drawings. Meet the requirements of the components of materials manufacturers, NRCA, SMACNA, and Copper Development Association, as they apply to this project.
05500-7
3.2.5 Prime all sheet metal that will come in contact with
bituminous materials with asphalt primer and allow to dry before applying bitumen.
3.2.6 Isolate dissimilar metals in contact by painting with a compatible bituminous coating, or by using an uncured neoprene gasket.
3.2.7 Sheet Metal with Flanges: Follow applicable published
requirements of membrane manufacturer.
3.2.8 Do not overlap edge metal. Allow 1/4" minimum spacing between edge metal pieces. Cover gap between adjacent edge metal with a joint cover 4 to 6" wide set in mastic.
3.2.9 Maintain neat appearance.
3.2.10 Touch up damaged paint surface.
3.2.11 Fasten every 12 inches minimum or closer as recommended by manufacturer.
3.3 TOLERANCES: Maximum offset from true alignment between adjacent new and existing members butting or in line: 1/8-inch.
3.4 SNOW GUARDS: Install snow guards as per manufacturer’s requirements.
3.5 STRUCTURAL STEEL ERECTION:
3.5.1 Erect structural steel in accordance with AISC Specification.
3.5.2 Make provision for erection loads and for sufficient temporary bracing tro maintain structure safe, plumb and in true alignment until completion of erection and installation of permanent bracing.
3.5.3 Do not field cut or alter structural members without approval of Contracting Officer or his Technical Representative.
3.5.4 After erection, prime welds, abrasions and surfaces not shop primed/galvanized except surfaces to be in contact with concrete. Use a primer consistent with shop coat.
3.5.5 Framed beam connections shall comply with Table II or Table III of the Ninth Edition of the AISC specification.
06100-1
DIVISION 6 - WOOD AND PLASTIC
SECTION 06100
ROUGH CARPENTRY
1.1.1 Miscellaneous wood framing and sheathing.
1.1.2 Concealed wood blocking.
1.1.3 Provide nails, bolts, screws, framing anchors, wall bracing, rough hardware and other items needed.
1.2 QUALITY ASSURANCE:
1.2.1 Lumber: Identify with grade stamp.
1.2.2 Fire retardant treatment to conform to requirements of
Underwriters' Laboratories (UL).
1.2.3 American Wood-Preservers’ Association (AWPA) Book of
Standards, Latest Addition.
1.3 REGULATORY REQUIREMENTS:
1.3.1 Conform to applicable codes for fire retardant treatment of wood surfaces for flame/fuel/smoke ratings.
1.4 REFERENCES:
1.4.1 NFPA - National Design Specification for Stress Grade Lumber and its Fastening.
1.4.2 PS 1 - Construction and Industrial Plywood.
1.4.3 PS 20 - American Softwood Lumber Standard.
1.4.4 Factory Mutual Global Manual 1-49, perimeter flashing.
1.5 RELATED WORK:
1.5.1 Section 05500 - Metal Fabrications
1.5.2 Section 07300- Shingle Roofing System
1.5.3 Section 07468- Aluminum Soffit, Fascia and Gutter Systems
1.5.4 Section 07510 - Built-up Roofing
06100-2
1.5.5 Section 07560 - EPDM Roofing System
1.6 SUBMITTALS:
1.6.1 Product Data: Submit data showing conformance with the
specifications.
1.6.2 Factory Mutual Global Manual 1-49 with plan and details to meet FM 1-90 wind load requirements.
1.6.3 Recycled Content: Submit data for all used and new materials that indicates quantity and weight of all recycled materials that are used in each delivery order.
2. PRODUCTS:
2.1 MATERIALS:
2.1.1 Lumber: PS 20, graded in accordance with NFPA Grading Rules;
maximum moisture content of 19 percent; FIR or SPF species; standard grade.
2.1.2 Softwood Plywood: PS 1; exterior quality match existing grade and thickness. Lumber to have visible grade stamp of an agency certified by
NFPA.
2.2 ACCESSORIES:
2.2.1 Bolts, Nuts, Washers, Lags and Screws: Medium carbon steel;
size and type to suit application; galvanized for exterior locations, high humidity locations and treated wood; plain finish for other interior locations.
2.2.1.1 All new wood blocking shall be fastened with
galvanized screws minimum 16” centers.
2.2.2 Fasteners: Toggle bolt type for anchorage to hollow masonry.
Expansion shield and lag bolt type for anchorage to solid masonry or concrete.
Bolts or power activated type for anchorage to steel.
2.2.2.1 All new wood blocking attached to a concrete deck
shall be minimum 1/4” x 3” zinc expansion anchors at 2’-0” centers.
3. EXECUTION:
3.1 SITE TREATMENT OF WOOD MATERIALS:
3.1.1 Prime paint surfaces in contact with cementitious materials.
3.1.2 Treat site-sawn ends. Allow preservative to cure prior to placing members.
3.2 INSTALLATION:
06100-3
3.2.1 Install miscellaneous blocking, furring, cants, nailing strips, framing and sheathing.
3.2.2 Install members true, plumb and level. Secure in place.
3.2.3 Space miscellaneous framing and furring at 16 inches o/c.
3.2.4 Construct members of continuous pieces of longest possible lengths.
3.2.5 On steel or wood decks lap all new wood plates a minimum 4” on a sound structural deck and fasten with galvanized threaded screws at a maximum 16” centers or as per FM 1-49 manual, whichever is more restrictive, all other wood blocking attached to new wood blocking shall be with galvanized threaded screws at maximum 16” ctrs. No nailing attachment shall be allowed.
Make sure that all wood blocking attachment is secured to sound structural decking and framing, stagger all new fasteners.
3.2.6 On concrete decks lap all new wood plated a minimum 4” on a sound structural deck and fasten with minimum 1/4” x 3” zinc. Expansion anchors at a maximum 24” centers or as per FM 1-49 manual, whichever is more restrictive.
3.2.7 All new plywood sheathing shall be attached with galvanized or plated screws at 6: centers at panel perimeter and at 8” centers within panel, no nailing attachment shall be allowed.
07240-1 QJVF 10-0045
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
SECTION 07240
EXTERIOR INSULATION AND FINISH SYSTEM
1.1 SCOPE: The work to be performed consists of furnishing all labor, materials, equipment, and miscellaneous to provide patching and repair of an exterior insulation and finish system. Bid shall include insulation system from minimum up to 2” thick. All insulation shall match existing.
1.2 DESCRIPTION: The exterior insulation and finish system shall be a job-fabricated exterior wall covering system consisting of insulation board, glass fabric reinforcing mesh, mechanical anchors, chopped fiberglass strands, polymer modified base coat and a choice of polymer modified textured finish with acrylic sealer, or synthetic finish with integral color finish. Color and texture to match existing adjacent finish.
1.3 QUALIFICATIONS: Manufacturer shall have regularly marketed an exterior insulated system in this country for at least five years and shall have satisfactorily completed a minimum of at least 50 installations.
1.4 SUBMITTALS:
1.4.1 Certificates of Compliance: Certificates of compliance shall be submitted in accordance with Section 01300 attesting that the finish coating system meets the specified requirements.
1.4.2 Instructions: The manufacturer's standard printed
instructions for installation of the system shall be submitted.
1.4.3 Samples: Samples indicating size, thickness, texture and color.
1.4.4 Guarantee: Written manufacturer's guarantee for a period of five years.
1.4.5 Recycled Content: Submit data for all used and new materials that indicates…