Attachment 1 10-0045 BID SCHEDULE.xlsx

XLSX spreadsheet 23 KB Posted

Attached to
Roofing IDIQ Federal contract opportunity
Solicitation number
FA4528-09-R-0020
Issued by
Department of the Air Force Global Strike Command

About this file

Attachment 1 - Bid Schedule (Base and Option Year)

View the file

Other files for this federal contract opportunity

Other files attached to Roofing IDIQ, newest first.
File Type Posted
FA4528-09-R-0020 Amendment 02.doc DOC document
Attachment 6 - Specification Revision 10-0045 07565, 1-2.pdf PDF
FA4528-09-R-0020 Amendment 01.doc DOC document
Attachment 2_Davis Bacon Wage Determination_Effective 15 Aug 08.doc DOC document
SF 1442 Solicitation - FA4528-09-R-0020.doc DOC document
Attachment 5 Recent and Relevant Experience for LPTA —
Attachment 8 - Seed Project Drawing.doc DOC document
Attachment 3 - Specifications 10-0045.pdf PDF
Attachment 7 - Seed Project Scope of Work.docx DOCX document
Attachment 6 - Seed Project Bid Schedule.xlsx XLSX spreadsheet
ATTACHMENT 4 RESPONSIBILITY.doc DOC document
Attachment 2A_Project Wage Determination_Roofer.doc DOC document
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

base year

Roofing Maintenance Contract Bid Schedule - QJVF 10-0045
ItemDescriptionUnitBase Year Estimated QuantityBase Year Unit PriceBase Year Total Price for Estimated Quantity
0001BASE-Investigative inspection-specified in Section 01010.Roof8
2BASE-Security delay time for all contractor's activity entering or exiting a secure area. The Contractor will assume, at his risk, 30 minutes time for access entry for a crew up to 6. Contractor shall notify the Contracting Officer or inspector verbally immediately following delay. 1 hr. min. unit.Crew Hour10
3BASE-Certified Asbestos and Lead Based Paint Inspector. Price per 1 Site Inspection. Min. 1 site inspection.Per Inspec8
4BASE-Asbestos Analysis- single sample. Price per sample. Min. 2 samples per site.EA30
5BASE-Lead Based Paint Analysis-single sample. Price per Sample. Min. 2 samples per site.EA30
6BASE-Sample analysis Summary Letter with lab results. 1 site per Report. Price per Report, min. 1 report.EA8
7BASE-Remove single layer of deteriorated BUR roof components (including felts, gravel surfacing and insulation); or standing seam metal roof system (including insulation and support system); or single-ply roof componets (including membrane, gravel surfacing and insulation); including repair preparation, to structural deck. 1 square min. unit.SQ250
8BASE-Remove multiple layers of deteriorated BUR roof components (including felts, gravel surfacing and insulation); or standing seam metal roof system (including insulation and support system); or single-ply roof componets (including membrane, gravel surfacing and insulation); including repair preparation, to structural deck. 1 square min. unit.SQ200
9BASE-Spud existing gravel surfacing. 1 Square foot minimum unit.SF10000
10BASE-Mud and tape or caulk existing flashing joints, etc. 1 Lineal foot minimum unit.LF1500
11BASE-Cut existing welds and remove existing steel curbs or supports. Minimum 1 foot length unit.LF40
12BASE-Install and weld new steel angle iron supports, up to 4"X4"X1/4". Miniumun 2' length.LF40
13BASE-Remove existing 1-1/2" Roof deck & replace with new. Minimum 1 square foot unit.SF200
14BASE-Remove and replace existing plywood soffits with ADX plywood, prime & paint to match existing.SF450
15BASE-Remove existing fascia/gravel stop and replace with new prefinished, galvanized steel fascia/ gravel stop and cleat. 1 square foot minimum unit.SF2000
16BASE-Remove existing reglet and counterflashing and replace with new galvanized 24 gauge steel reglet and counterflashing. 1 square foot minimum unit.SF450
17BASE-Remove existing counterflashing and replace with new galvanized or prefinished, galvanized counterflashing. 1 square foot minimum unit.SF250
18BASE-Remove existing and furnish and install new wood blocking at roof perimeters, control joints, roof penetration curbs and other curb locations. 1 board foot minimum unit.BF10000
19BASE-Remove existing vent flashing and replace with new lead vent flashing as shown on NRCA detail BUR-18 (01).EA30
20BASE-Remove existing metal parapet/curb cap and replace with new prefinished galvanized steel. 1 square foot min. unit.SF1070
21BASE-Remove existing siding and replace with new 12" wide vertical prefinished steel panels with steel furring channels.SF120
22BASE-Remove existing EFIS siding system and replace with new EFIS siding system.SF100
23BASE-Install new warranty sign. One sign minimum unit.EA8
24BASE-Remove existing roof drain sump. Replace with new. Reconnect to drain piping. See NRCA detail BUR-20 (01).EA25
25BASE-Remove existing expansion joint and furnish and install new all metal expansion joint cover similar to NRCA detail SM-22 (01). 1 lineal foot minimum unit.LF260
26BASE-Furnish and install new prefinished galvanized steel scupper. Minimum 12" wide X 6" out.EA40
27BASE-Remove and replace existing continuous snow/ice gaurd. Minimum 5 L.F.LF120
28BASE-Remove and replace existing fabricated, prefinished, galvanized steel, 6" raingutter system. Minimum 10 L.F.LF120
29BASE-Remove and replace existing fabricated, prefinished, open faced, galvanized steel 6" downspouts. Min. 8 L.F.LF80
30BASE-Remove and replace existing prefinished 4"X5" aluminum continuous raingutters. 10' minimum unit.LF120
31BASE-Remove and replace existing prefinished 5"X6" aluminum continuous raingutters. 10' minimum unit.LF80
32BASE-Remove and replace existing prefinished aluminum continuous 2"X3" downspouts. 10' minimum unit.LF140
33BASE-Remove and replace existing prefinished aluminum continuous 3"X4" downspouts. 10' minimum unit.LF40
34BASE-Furnish and install new precast concrete splashblock. Minimum one unit.EA40
35BASE-Furnish and install specified vapor barrier. 1 square minimum unit.SQ200
36BASE-Furnish and install specified underlayment. 1 square minimum unit.SQ120
37BASE-Furnish and install specified polyisocyanurate insulation over prepared surface area. Thickness is per layer of insulation and is identified in specification. 1 board foot minimum unit.BF334000
38BASE-Furnish and install specified tapered polyisocyanurate insulation over prepared surface area. Thickness is average layer of insulation. 1 board foot minimum unit.BF20000
39BASE-Furnish and install specified 5/8" DensDeck roof board (Type X) over prepared surface area. Thickness is average layer of insulation. 1 board foot minimum unit.SF60000
40BASE-Furnish and install specified 3/4 inch perlite insulation over prepared surface area. Thickness is per layer of insulation. 1 square foot minimum unit.SF60000
41BASE-Furnish and install specified tapered edge strips. 1 lineal foot minimum unit.LF800
42BASE-Furnish and install specified 4 inch x 4 inch cant strips. 1 lineal foot minimum unit.LF1600
43BASE-Furnish and install asphalt system as specified, including membrane, bitumen and surfacing. 1 square minimum unit.SQ425
44BASE-Furnish and install specified asphalt base flashing system as specified.SF2400
45BASE-20 year asphalt system warranty, less than 100 squares per roof. 1 roof minimum unit.Roof5
46BASE-20 year asphalt system warranty, 100 squares or more per roof. 1 roof minimum unit.SQ250
47BASE-Furnish and install SBS modified bitumen system as specified, including membrane, base sheet system and bitumen. 1 square minimum unit.SQ50
48BASE-Furnish and install specified SBS modified bitumen base flashing system as specified.SF240
49BASE-20 year SBS Modified Bitumen system warranty, less than 100 squares per roof. 1 roof minimum unit.Roof1
50BASE-20 year SBS Modified Bitumen system warranty,100 squares or more per roof. 1 roof minimum unit.SQ40
51BASE-Complete asphalt roof membrane sampling as specified. 1 each minimum unit.EA2
52BASE-EPDM Membrane 60 mil fully adhered system. 1 square minimum unit.SQ200
53BASE-EPDM Flashing.SF300
54BASE-Rubber Walk Pad. Minimum 6.25 S.F.SF50
55BASE-20 year EPDM Warranty less than 100 squares per roof. 1 roof minimum unit.Roof2
56BASE-20 year EPDM Warranty 100 squares or more per roof. 1 roof minimum unit.SQ120
57BASE-Furnish and install aluminum roof coating.SF100
58BASE-RC 2000 Spray-On CoatingSF200
59BASE-Embed fiberglass mesh in coating(coating included)SF200
60BASE-Remove and replace existing plywood roof sheathing to match existing. Min. 32 SF.SF400
61BASE-Remove and replace existing shingles and felt underlayment. Minimum one square.SQ50
62BASE-Modified asphalt underlayment, minimum 10 S.F.SF600
63BASE-Remove & replace metal drip edge, minimum 10 L.F.LF300
64BASE-Valley with modified asphalt underlayment and galvanized metal flashing, minimum 200 L.F.LF80
65BASE-Remove and replace existing ridge cap, min. 10 L.F.LF80
66BASE-Continuous Ridge Vent, minimum 10 L.F.LF80
TOTAL BASE YEAR

Bid Schedule &P

QJVF 10-0045

option year

Roofing Maintenance Contract Bid Schedule - QJVF 10-0045
ItemDescriptionUnitOption Year Estimated QuantityOption Year Unit PriceOption Year Total Price for Estimated Quantity
0001BASE-Investigative inspection-specified in Section 01010.Roof8
2BASE-Security delay time for all contractor's activity entering or exiting a secure area. The Contractor will assume, at his risk, 30 minutes time for access entry for a crew up to 6. Contractor shall notify the Contracting Officer or inspector verbally immediately following delay. 1 hr. min. unit.Crew Hour10
3BASE-Certified Asbestos and Lead Based Paint Inspector. Price per 1 Site Inspection. Min. 1 site inspection.Per Inspec8
4BASE-Asbestos Analysis- single sample. Price per sample. Min. 2 samples per site.EA30
5BASE-Lead Based Paint Analysis-single sample. Price per Sample. Min. 2 samples per site.EA30
6BASE-Sample analysis Summary Letter with lab results. 1 site per Report. Price per Report, min. 1 report.EA8
7BASE-Remove single layer of deteriorated BUR roof components (including felts, gravel surfacing and insulation); or standing seam metal roof system (including insulation and support system); or single-ply roof componets (including membrane, gravel surfacing and insulation); including repair preparation, to structural deck. 1 square min. unit.SQ250
8BASE-Remove multiple layers of deteriorated BUR roof components (including felts, gravel surfacing and insulation); or standing seam metal roof system (including insulation and support system); or single-ply roof componets (including membrane, gravel surfacing and insulation); including repair preparation, to structural deck. 1 square min. unit.SQ200
9BASE-Spud existing gravel surfacing. 1 Square foot minimum unit.SF10000
10BASE-Mud and tape or caulk existing flashing joints, etc. 1 Lineal foot minimum unit.LF1500
11BASE-Cut existing welds and remove existing steel curbs or supports. Minimum 1 foot length unit.LF40
12BASE-Install and weld new steel angle iron supports, up to 4"X4"X1/4". Miniumun 2' length.LF40
13BASE-Remove existing 1-1/2" Roof deck & replace with new. Minimum 1 square foot unit.SF200
14BASE-Remove and replace existing plywood soffits with ADX plywood, prime & paint to match existing.SF450
15BASE-Remove existing fascia/gravel stop and replace with new prefinished, galvanized steel fascia/ gravel stop and cleat. 1 square foot minimum unit.SF2000
16BASE-Remove existing reglet and counterflashing and replace with new galvanized 24 gauge steel reglet and counterflashing. 1 square foot minimum unit.SF450
17BASE-Remove existing counterflashing and replace with new galvanized or prefinished, galvanized counterflashing. 1 square foot minimum unit.SF250
18BASE-Remove existing and furnish and install new wood blocking at roof perimeters, control joints, roof penetration curbs and other curb locations. 1 board foot minimum unit.BF10000
19BASE-Remove existing vent flashing and replace with new lead vent flashing as shown on NRCA detail BUR-18 (01).EA30
20BASE-Remove existing metal parapet/curb cap and replace with new prefinished galvanized steel. 1 square foot min. unit.SF1000
21BASE-Remove existing siding and replace with new 12" wide vertical prefinished steel panels with steel furring channels.SF120
22BASE-Remove existing EFIS siding system and replace with new EFIS siding system.SF100
23BASE-Install new warranty sign. One sign minimum unit.EA8
24BASE-Remove existing roof drain sump. Replace with new. Reconnect to drain piping. See NRCA detail BUR-20 (01).EA25
25BASE-Remove existing expansion joint and furnish and install new all metal expansion joint cover similar to NRCA detail SM-22 (01). 1 lineal foot minimum unit.LF260
26BASE-Furnish and install new prefinished galvanized steel scupper. Minimum 12" wide X 6" out.EA40
27BASE-Remove and replace existing continuous snow/ice gaurd. Minimum 5 L.F.LF120
28BASE-Remove and replace existing fabricated, prefinished, galvanized steel, 6" raingutter system. Minimum 10 L.F.LF120
29BASE-Remove and replace existing fabricated, prefinished, open faced, galvanized steel 6" downspouts. Min. 8 L.F.LF80
30BASE-Remove and replace existing prefinished 4"X5" aluminum continuous raingutters. 10' minimum unit.LF120
31BASE-Remove and replace existing prefinished 5"X6" aluminum continuous raingutters. 10' minimum unit.LF80
32BASE-Remove and replace existing prefinished aluminum continuous 2"X3" downspouts. 10' minimum unit.LF140
33BASE-Remove and replace existing prefinished aluminum continuous 3"X4" downspouts. 10' minimum unit.LF40
34BASE-Furnish and install new precast concrete splashblock. Minimum one unit.EA40
35BASE-Furnish and install specified vapor barrier. 1 square minimum unit.SQ200
36BASE-Furnish and install specified underlayment. 1 square minimum unit.SQ120
37BASE-Furnish and install specified polyisocyanurate insulation over prepared surface area. Thickness is per layer of insulation and is identified in specification. 1 board foot minimum unit.BF300000
38BASE-Furnish and install specified tapered polyisocyanurate insulation over prepared surface area. Thickness is average layer of insulation. 1 board foot minimum unit.BF20000
39BASE-Furnish and install specified 5/8" DensDeck roof board (Type X) over prepared surface area. Thickness is average layer of insulation. 1 board foot minimum unit.SF60000
40BASE-Furnish and install specified 3/4 inch perlite insulation over prepared surface area. Thickness is per layer of insulation. 1 square foot minimum unit.SF60000
41BASE-Furnish and install specified tapered edge strips. 1 lineal foot minimum unit.LF800
42BASE-Furnish and install specified 4 inch x 4 inch cant strips. 1 lineal foot minimum unit.LF1600
43BASE-Furnish and install asphalt system as specified, including membrane, bitumen and surfacing. 1 square minimum unit.SQ425
44BASE-Furnish and install specified asphalt base flashing system as specified.SF2400
45BASE-20 year asphalt system warranty, less than 100 squares per roof. 1 roof minimum unit.Roof5
46BASE-20 year asphalt system warranty, 100 squares or more per roof. 1 roof minimum unit.SQ250
47BASE-Furnish and install SBS modified bitumen system as specified, including membrane, base sheet system and bitumen. 1 square minimum unit.SQ50
48BASE-Furnish and install specified SBS modified bitumen base flashing system as specified.SF240
49BASE-20 year SBS Modified Bitumen system warranty, less than 100 squares per roof. 1 roof minimum unit.Roof1
50BASE-20 year SBS Modified Bitumen system warranty,100 squares or more per roof. 1 roof minimum unit.SQ40
51BASE-Complete asphalt roof membrane sampling as specified. 1 each minimum unit.EA2
52BASE-EPDM Membrane 60 mil fully adhered system. 1 square minimum unit.SQ200
53BASE-EPDM Flashing.SF300
54BASE-Rubber Walk Pad. Minimum 6.25 S.F.SF50
55BASE-20 year EPDM Warranty less than 100 squares per roof. 1 roof minimum unit.Roof2
56BASE-20 year EPDM Warranty 100 squares or more per roof. 1 roof minimum unit.SQ120
57BASE-Furnish and install aluminum roof coating.SF100
58BASE-RC 2000 Spray-On CoatingSF200
59BASE-Embed fiberglass mesh in coating(coating included)SF200
60BASE-Remove and replace existing plywood roof sheathing to match existing. Min. 32 SF.SF400
61BASE-Remove and replace existing shingles and felt underlayment. Minimum one square.SQ50
62BASE-Modified asphalt underlayment, minimum 10 S.F.SF600
63BASE-Remove & replace metal drip edge, minimum 10 L.F.LF300
64BASE-Valley with modified asphalt underlayment and galvanized metal flashing, minimum 200 L.F.LF80
65BASE-Remove and replace existing ridge cap, min. 10 L.F.LF80
66BASE-Continuous Ridge Vent, minimum 10 L.F.LF80
TOTAL OPTION YEAR
TOTAL BASE YEAR
TOTAL

Bid Schedule &P

QJVF 10-0045

File details come from the government source that posted it. Updated .