This document is a set of Questions and Answers related to the Demineralizer Water Services solicitation FA448424R0014.

The key details are:

  • The solicitation requires a demineralizer water trailer that can process 200 gallons per minute, with an output of 100 gallons per minute.
  • The current trailer is 42 feet long, and the new trailer can be 48-52 feet long.
  • The new contractor will be required to provide the demineralizer water trailer, as the current trailer belongs to the incumbent contractor.
  • The pressure coming from the sand filters to the demineralizer trailer is unknown.
  • The demineralizer water feeds directly into the filter system, not a storage tank.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA448424R0014

Demineralizer Water Services Questions and Answers

1. We were unable to find the flow rate supply to the DI trailer and outlet flow rates. Could you see if you if we can get the specs for this?

a. The system pumps 200 gallons per minute going into the trailer and get about 100 gallons per minute going out of the trailer.

2. Just confirming that a 10MG DI trailer (48’-52’) trailer will fit in the location of where the DI trailer will be stowed. Please confirm?

a. The current trailer is 42 feet long with plenty of space left. The space would be able to fit a 48–52-foot trailer.

3. Do we have to provide the trailer or does it already exist in place?

a. The trailer that is currently on location belongs to the current contractor. The new contractor would have to provide the trailer.

4. The spec calls out the feed water to the DI trailer being feed from sand filters. Do we know the pressure coming off of the sand filters to the DI trailer?

a. Unfortunately, the pressure coming off the filters cannot be determined at this time.

5. Are we feeding to a DI storage tank or directly into the process?

a. The water feeds directly into the filter system.