DD_1070_Termite_inspection.pdf

PDF 70 KB Posted

Attached to
JB MDL Pest Control Federal contract opportunity
Solicitation number
FA4484-16-Q-0005
Issued by
Department of the Air Force Air Mobility Command

About this file

Termite Inspection DD 1070

View the file

Other files for this federal contract opportunity

Other files attached to JB MDL Pest Control, newest first.
File Type Posted
Questions_Answers_Pest.docx DOCX document
Pest_Control_PWS1_20160601.rtf RTF text file
DD_1532_Pest_Manage_Report.xlsx XLSX spreadsheet
Wage_Determination_Lakehurst.docx DOCX document
Questionnarie_letter.docx DOCX document
FA4484-16-Q-0005_Revised_12_Aug_16.docx DOCX document
Weekly_Mosquito_Plan.docx DOCX document
Pest_Control_Ind_Price_List1_20160812.xlsx XLSX spreadsheet
Pest_Manage_Plan.pdf PDF
Wage_Determination_Burlington.docx DOCX document
Pest_Control_Survey_Insp_Sheet.docx DOCX document
Anti-terrorism_Medical.rtf RTF text file
Security_Forces_Appendix_used.rtf RTF text file
Safety_Guide_for_Civilian_Contractors.docx DOCX document
Past_Performance_Questionnaire_used.rtf RTF text file
Intregated_Man_stray_annimals.pdf PDF
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TERMITE AND WOOD DECAY INSPECTION

DATE INSPECTED BUILDING NUMBER

INSTALLATION TYPE BUILDING

PERM TEMP

INSPECTOR

FAVORABLE TERMITE AND FUNGI INFESTATION CONDITIONSI.

WOOD IN CONTACT WITH SOIL

FORM BOARDS LEFT IN CONCRETE

WOOD MEMBERS SET IN CONCRETE FLOOR

WOOD STEPS IN CONTACT WITH SOIL

WOOD STEPS WITHOUT SHIELDS

WOOD SIDING IN CONTACT WITH SOIL

PIPES IN CONTACT WITH SOIL AND WOOD

NO SHIELDS ON FOUNDATION

FAULTY TERMITE SHIELD

POOR VENTILATION UNDER BUILDING

WATER COLLECTIONS UNDER BUILDING

VINES AND SHRUBS AGAINST BUILDING

LEAKY PLUMBING IN BUILDING

WOOD SCRAP PILED UNDER BUILDING

LOOSE WIRE IN CONTACT WITH SOIL

OTHER (Specify)

LOCATION OF INFESTATIONSII.

FOUNDATION TIMBERS

WOOD PILLARS

SILLS

CROSS BEAMS

FURNITURE

FLOOR JOIST

FLOOR

STUDS

BASE BOARDS

DOOR FRAMES

WINDOW FRAMES

STEPS

ROOF

OTHER (Specify)

TYPE OF TERMITEIII. TYPE OF FUNGIIV. DAMAGEV.

SUBTER-

RANEAN

NONSUBTER-

RANEAN

WOOD DECAY

WOOD

STAINING

STRUCTURAL

WEAKENING

SUPERFICIAL

ESTIMATED COST

TYPE

REPAIR AND TREATMENTVI.

RECM ACCOMP TYPE RECM ACCOMP

REMOVAL OF WOOD FROM SOIL CONTACT

SEALING CRACKS IN CONCRETE

POINTING UP POOR MORTAR

LOWERING GRADE LEVEL

CAPPING CONCRETE FOUNDATION

IMPROVING DRAINAGE UNDER BUILDING

IMPROVING VENTILATION UNDER BUILDING

REPAIR OF TERMITE SHIELDS

REMOVAL OF CONCRETE FORMS

REMOVAL OF VINES AND SHRUBS

REMOVAL OF WOOD TRASH

OTHER (Specify)

APPLICATION OF POISON DUST TO SHELTER TUBES

YES NO

CHEMICAL USED

SOIL POISON

YES NO

TRENCH DEPTH LINEAR FEET CHEMICAL USED

REPLACEMENT OF DAMAGED

WOOD YES NO

NO. OF M BD FEET REPLACED UNTREATED DIPPED SOAKED SPRAYED PRESSURE TREATED

DRILLING AND FLOODING TREATMENTS

YES NO

CHEMICAL USED

WOOD INJECTION FOR DRY WOOD TERMITE

YES NO

CHEMICAL USED

CHEMICAL CONTROLVII.

COSTVIII.

LABOR MATERIAL OTHER TOTAL

TREATMENT EFFECTIVENESSIX.

DATE REMARKS INSPECTOR

DATE REMARKS INSPECTOR

DATE REMARKS INSPECTOR

DATE TITLE OF INDIVIDUAL AFFECTING REPAIR AND TREATMENT SIGNATURE

DD Form 1070, FEB 58

DATEINSPECTED:
BUILDING_NUMBER:
INSTALLATION:
INSPECTOR1:
ESTIMATED_COST:
CHEMICAL_USED:
TRENCH_DEPTH:
LINEAR_FEET:
CHEMICAL_USED1:
NO_OF_M_ED_FEET_REPLACED:
UNTREATED:
DIPPED:
SOAKED:
SPRAYED:
PRESSURE_TREATED:
CHEMICAL_USED2:
CHEMICAL_USED3:
LABOR:
MATERIAL:
OTHER:
TOTAL: 0
DATE1:
REMARKS1:
INSPECTOR2:
DATE2:
REMARKS2:
INSPECTOR3:
DATE3:
REMARKS3:
INSPECTOR4:
DATE4:
TITLE_OF_INDIVIDUAL_AFFEC:
Reset:
title:
xperm: Off
xtemp: Off
x1i: Off
x1a: Off
x1b: Off
x1c: Off
x1d: Off
x1e: Off
x1f: Off
x1g: Off
x1h: Off
x1j: Off
x1k: Off
x1l: Off
x1m: Off
x1n: Off
x1o: Off
x2a: Off
x2c: Off
x2d: Off
x2e: Off
x2f: Off
x2g: Off
x2h: Off
x2i: Off
x2j: Off
x2k: Off
x2l: Off
x2m: Off
OTHER1:
OTHER2:
x3a: Off
x3b: Off
x4a: Off
x4b: Off
x5a: Off
x5b: Off
acc6a: Off
REC6a: Off
acc6b: Off
acc6c: Off
REC6c: Off
acc6d: Off
REC6d: Off
acc6e: Off
REC6e: Off
acc6f: Off
REC6f: Off
REC6g: Off
acc6g: Off
REC6b: Off
acc6h: Off
REC6h: Off
acc6i: Off
REC6i: Off
acc6j: Off
REC6j: Off
acc6k: Off
REC6k: Off
other_repair1:
REC6l: Off
acc6l: Off
other_repair2:
REC6m: Off
acc6m: Off
xyes7c: Off
xno7c: Off
xyes7a: Off
xno7a: Off
xyes7b: Off
xno7b: Off
xyes7d: Off
xno7d: Off
xyes7e: Off
xno7e: Off

File details come from the government source that posted it. Updated .