Attachment 9_766 Asbestos Report P2-00027-24.pdf
PDF 2 MB Posted
- Attached to
- Request For Proposal (RFP) #FA445225R0032- 43d Air Mobility Operations Group (AMOG) Building 766 Repair
- Solicitation number
- FA445225R0032
About this file
This document is a Focus Asbestos Survey Report for Building 766 at Fort Liberty, North Carolina, prepared by Ayuda Management Corporation for the Directorate of Public Works. The survey, conducted on July 18, 2024, by a North Carolina accredited inspector, was part of a project (P2-00027-24) to repair the facility interior, which includes replacing flooring, repairing restroom tiles, repairing interior doors, replacing windows, replacing lighting and ceiling fans in the storage area, and constructing a new office.
The laboratory analysis by EMSL Analytical, Inc. using AHERA Method 40CFR 763 revealed no asbestos-containing materials (ACM) in the samples tested. The building, constructed in 1977 and currently used as an NBC Training Facility, is a one-story brick structure with painted sheetrock interior walls, concrete flooring with 12" x 12" vinyl tiles, and suspended ceiling tiles. The report includes a Notice to Occupants warning that while no ACM was detected in this survey, caution should be exercised during renovation to avoid potential asbestos exposure, with specific guidelines provided for handling suspected materials.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Focus Asbestos Survey to Repair Facility Interior
Building 766 Fort Liberty, North Carolina
Prepared by David L. Clark of Ayuda Management Corporation For the Directorate of Public Works, Fort Liberty, North Carolina
Building 766 was inspected for asbestos by David L. Clark, inspector certification number: NC 11788 on July 18, 2024.
Photos Not Taken Pending Fort Liberty Photography Authorization
Introduction
Scope of the Investigation
This report documents the focused asbestos inspection and survey of Building 766 at Fort Liberty, North Carolina for project number P2-00027-24. The work description is detailed in the Facilities Engineering Work Request DA Form 4283 attached in this report. The work: Repair building interior to include replace flooring, repair damaged tile in restroom, repair interior doors, replace windows, replace lighting in storage area, replace ceiling fans in storage area, and construct a new office.
Background
Building 766 is a one-story brick structure with a sloped metal roofing system. The interior walls are constructed of painted sheetrock. The floor system is concrete throughout the building and is covered with 12” x 12” inch vinyl floor tiles, in the classroom and office area. The ceilings are suspended with 2’ x 2’ ceiling tiles attached. Building 766 is approximately 4,2 00 Sq. Ft. and was constructed in 1977. Building 766 is currently used as an NBC Training Facility. Photos of Materials in Building 766 were not taken pending Fort Liberty Photography Authorization.
Description of study
Investigation
Building 766 was visually inspected for suspected asbestos containing materials (ACM) by a North Carolina accredited inspector. Bulk samples of all suspect ACM’s were collected. This report details ACM as identified at the time of inspection only. Samples of materials to be disturbed during the course of work to be performed were taken and sent to a NVLAP certified laboratory for analysis. The approximate location where bulk samples were obtained are shown on the building floor plan included in this report. However, if suspect materials are discovered during renovation in concealed spaces, renovation activities should stop and the materials sampled by a North Carolina accredited asbestos inspector.
In compliance with the AHERA regulations, material is considered an Asbestos Containing Material (ACM) when it contains greater than one percent asbestos. Likewise, in this report, any material containing concentrations greater than one percent asbestos will be considered “positive”. Occasionally, materials containing less than one percent asbestos, or not sampled, are assumed to be a “positive” asbestos containing material at the discretion of the inspectors. A narrative discussion of the AHERA ACM types (i.e., thermal systems insulation, miscellaneous and surfacing materials) found in the building is included in this report where relevant. Bulk sample information appears, estimated quantities of individual asbestos containing materials, material characterization of asbestos containing materials appears on the Asbestos Table.
Conclusions
Thermal System Insulation
TSI is insulation material applied to pipes, fittings, tanks, ducts, or on other interior structural components to prevent heat loss or gain, or water condensation, or for other purposes. The Thermal System Insulation in Building 766 was observed to be fiberglass at the time of sampling.
Miscellaneous Materials
Miscellaneous Materials include building material on structural components, structural members, or fixtures, such as floor and ceiling tiles, and do not include surfacing or TSI. Asbestos was not detected in the miscellaneous materials sampled in Building 766 at the time of the sampling.
Surfacing
Surfacing Material is friable material that is sprayed on, troweled on, or otherwise applied to surfaces for decorative or other purposes. Surfacing Material was not observed in Building 766 at the time of sampling.
ASBESTOS-CONTAINING MATERIAL WAS NOT DETECTED.
SF.-Square Foot, LN.-Linear Foot, CF.-Cubic Foot Amounts are estimated, Contractor is responsible for exact measurements.
Condition-Good, Fair, Poor.
ACBM Type-T=Thermal Insulation, Misc=Miscellaneous, S=Surfacing.
Friable: Y=Yes, N=Not Friable.
NPACM-No Presumed Asbestos Containing Material.
Disturbance Potential-Low Potential Damage, Potential Damage, Potential Significantly Damage.
Table of Asbestos Containing Materials
Building Fort Liberty, North Carolina
MATERIAL 0BCHARACTERISTICS 1BASSESSMENT
2BSample Type 3BHomogenous Area /Location Yes/No/Presumed %
Asbestos Type Quantity (If ACM)
Friable Condition
Disturbance Potential
Misc Black Cove Base Throughout No Throughout No No Low
Misc 12 x 12 Gray Floor Tile
Classroom & Offices Approx 1,445 Sq. Ft.
No Approx 1,445 Sq. Ft. No Good Low
DA Form 4283
Chain of Custody
Analytical Report
Photos of Materials hotos Not Taken Pending Fort Liberty Photography Authorization
Sample Locations
NOT TO SCALE
Accreditations
ASBESTOS-CONTAINING MATERIALS (ACM) ARE
PRESENT IN THIS BUILDING
ACM INCLUDES: THE BROWN/TAN VINYL FLOORING OVER
CONCRETE FLOOR IN ROOM 13, THE JOINT COMPOUND IN THE
SHEETROCK WALLS IN THE INTERIOR WALLS
UNLESS DISTURBED OR DAMAGED THE ACM WILL NOT
RELEASE HARMFUL FIBERS
ROUTINE HOUSEKEEPING WILL NOT RELEASE
HARMFUL FIBERS
DISTURBANCE OF THESE MATERIALS MAY PRESENT A
DANGER BY RELEASING ASBESTOS FIBERS. ASBESTOS
FIBERS ARE A HEALTH HAZARD AND MAY CAUSE LUNG
CANCER AND LUNG DISEASE.
AVOID CREATING ACM DUST
DO NOT DISTURB ACM
SUBMIT A DEMAND MAINTENANCE ORDER TO REPORT
DAMAGED ACM
FOR QUESTIONS:
CONCERNING ACM, CALL 910-322-6338
CONCERNING HEALTH, CALL 910-643-2447
TO SUBMIT A WORK REQUEST, 910-396-0321 or https://www.armymaintenance.com/arma
NOTICE TO OCCUPANTS
Inspection Date 10/18/2023, Building 8-3710 Reference: OSHA 29 CFR 1910.1001 and 1926.1101 https://www.armymaintenance.com/arma
| Focus Asbestos Survey to Repair Facility Interior |
| Building 766 Fort Liberty, North Carolina |
| Homogenous Area /Location |
| Sample Type |
| ASSESSMENT |
| CHARACTERISTICS |
| Introduction |
| Scope of the Investigation |
| Investigation |
| Conclusions |
| Miscellaneous Materials |
| Surfacing |
File details come from the government source that posted it. Updated .