E_-_Facility_Inventory_-_RP_&_Non-RP.xlsx

XLSX spreadsheet 13 KB Posted

Attached to
NPTU Facility Maintenance
Solicitation number
FA441819RA011
Issued by

About this file

Attachment E to PWS Facility Inventory Real and Non Real Property

View the file

Other files

File Type Posted
REVISED_Questions_and_Answers_40_and_41.pdf PDF
NPTU_FAC_MX_Pricing_Worksheet_REVISED_05_FEB_19.pdf PDF
Inspection_Checklist.docx DOCX document
NPTFCH~3.PDF PDF
FA441819RA011_-_Questions_and_Answers.pdf PDF
NPTFCH~2.PDF PDF
H1MB10~1.PDF PDF
NPTF_Charleston_OMSI_Manual_Part_IV_Cover_and_TOC.pdf PDF
G7LPV0~1.PDF PDF
Site_Visit_Attendance__Redacted.pdf PDF
WD_2015-4427_Rev_10_12_26_2018.pdf PDF
NPTF_Charleston_OMSI_Manual_Part_IV_Section_4_HVAC.pdf PDF
NPTU_FAC_MX_Pricing_Worksheet_8_Jan_19.doc DOC document
PPQ_NPTU_Facility_Maintenance.pdf PDF
FA441819RA011_Facility_Mx_Site-Visit_Agenda.pdf PDF
NPTU_Facility_Maintenance_Site_Visit.pdf PDF
Appendix_J_-_Engineering_Technical_Advisory_Legionellos_Mitigation_Actions.docx DOCX document
A_-_Real_Prop_Equip_Inventory.xlsx XLSX spreadsheet
G_-_Points_of_Demarcation.docx DOCX document
C_-_Service_Call_Data_-_Real_Property.xlsx XLSX spreadsheet
NPTU_PWS__20_Dec_2018.pdf PDF
I_-__Electrical_Substation_Inventory.xlsx XLSX spreadsheet
B_-_Equip_Inventory_-_NR_Property.xlsx XLSX spreadsheet
Appendix_K_-_Contractor_Base_Security_and_Access.docx DOCX document
NPTU_FAC_MX_Pricing_Worksheet_8_Jan_19.pdf PDF
REVISED_Solicitation_-_FA441819RA011_NPTU_Facility_Maintenance.pdf PDF
H_-_Backflow_Preventer_Inventory.xlsx XLSX spreadsheet
D_-_Service_Call__Data_-_Non-Real.xlsx XLSX spreadsheet
PPQ_NPTU_Facility_Maintenance.pdf PDF
Appendix_L_-_Contractor_Special_Conditions_05JUN18.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Bldg #Common Building TitleYear BuiltBuilding Inspection RequiredGross SF From PRCRemarks
YNFX-20BargeNo
IX-516BargeNo
YFN-797BargeNo
Y-C1596BargeNo
2341AOffice TrailerNo
2341BOffice TrailerNo
339North Annex Training Support Facility1964Yes9,743Building 00339 is a 9,743 square foot, 1-story shop facility which consists of a classroom, automated cutting area, and offices. Lighting is primarily T12 fluorescent fixtures controlled manually. HVAC needs are met with seven heat pump split systems and three PTAC units. All of these units are controlled by manual thermostats.
420North Pier1988No
2312South Pier1993No
2314Training Support Building (TSB-1)1992Yes73,659Building 02314 is a 73,659 square foot, 3-story training facility with classrooms, labs, and offices. Approximately 20% of the building is a radiological support area. The building is operated 24/7, though most of the occupants are present during daytime hours on weekdays.

Lighting consists of a combination of T8 linear fluorescent fixtures and compact flourescent lights (CFLs). Interior lighting is controlled manually by wall switches, with the exception of some private offices on the second floor which have occupancy sensors. Exterior lighting is composed of high-intensity discharge (HID) wallpacks, which are controlled by photocells.

- Domestic hot water is provided by a central electric tank-type water heater.

- The entire building is air conditioned and heated. The building is condidioned by a series of air handling units (AHUs) with zone-level fan-powered variable air volume terminal boxes with electric reheat. Cooling water supplied by air cooled chillers located on the northwest exterior of the building. Air handlers utilize DDC controls and VAVs have pneumatic controls.

2626 Security Entry Access Point (SAEP) 2018 Yes 10187 The SAEP (Building 2626) is located on the central axis of the parking lot and opens onto a campus type quad between Building 2314 and Building 2701. There is a sidewalk network established between all the training buildings, X-Ray South and X-Ray north, and the SAEP for the ease of pedestrian flow for students and training staff. This sidewalk network also serves as emergency vehicle access within the complex and around the buildings.

-The exterior walls are cast-in-place architectural finished concrete with a horizontal ribbed form liner and form ties that form a pattern on the elevation. Walls are designed to meet blast resistant criteria.

-The building exterior does not have any windows, interior borrowed light windows are 1/4-inch wire glass in hollow metal frames, where located in 1-hour fire walls and 1/4-inch tempered glass in hollow metal frames at nonrated walls.

-Exterior doors are heavy duty steel construction designed to meet the blast resistant criteria.

-Roofing System: Two ply granular surface modified bitumen roof system over a ½-inch glass mat gypsum cover board and five inches of polyisocyanurate insulation.

2701 Training Support Building (TSB-2) 2018 Yes 116,583 TSB-2 (Building 2701) is s a three-story training and support facility located to the south of Building 2314 and close to the entrance to X-Ray South. This locates the building as close as possible for the Support Systems Complex (SSC) and its utilities. The warehouse and SSC have access through a door on the east side and have all the external equipment tanks located under a canopy structure. The access to the high bay is through a door on the south end of the facility for large truck and vehicles. The main entrance is located on the north side of the building directly across from the entrance to Building 2314. Contains high bay with Engineroom Team Trainer (ERTT) simulators.

-Exterior wall system are cast-in-place architectural finished concrete with a horizontal ribbed form liner and form ties that form a pattern on the elevation. Walls are designed to meet blast resistant criteria. The building exterior does not have any windows, interior borrowed light windows are 1/4-inch wire glass in a hollow meteral frames, where located in 1-hour fire walls and 1/4-inch tempered glass in a hollow metal frames at nonrated walls.

-Exterior doors are heavy duty steel construction designed to meet blast resistant criteria. Exterior doors are provided with automatic closers and panic hardware as need for code egress compliance. UL-listed interior fire doors are located and installed in conformance to NFPA No. 80, "Fire Doors and Windows."

-Roofing System: Two ply granular surface modified bitumen roof system over a ½-inch glass mat gypsum cover board and five inches of polyisocyanurate insulation.

2711 Training Support Building (TSB-2A) 2018 Yes 126,400 TSB-2A (Building 2711) is a three-story training and support facility located to the west of Building 2314 and to the north of the SAEP and is designated an Operational Training Facility. The auditorium and cafeteria are located on the south and east sides of the building to be closest to the campus quad and other buildings for ease of personnel access. There is a dumpster complex in the northeast corner of the new parking lot located close to the north gate for access from the secure side. There are gates and concrete screen walls around the dumpsters. The Hazardous Material Storage Area is located north of TSB-2 inside the secure fence. The Hazardous Waste Storage Area is located in the northeast corner of the parking lot. This is required to be located outside the K-30 arc for Wharf alpha so they need to be on the north side of the site.

-Exterior wall system are cast-in-place architectural finished concrete with a horizontal ribbed form liner and form ties that form a pattern on the elevation. Walls are designed to meet blast resistant criteria. The building exterior does not have any windows, interior borrowed light windows are 1/4-inch wire glass in a hollow meteral frames, where located in 1-hour fire walls and 1/4-inch tempered glass in a hollow metal frames at nonrated walls.

-Exterior doors are heavy duty steel construction designed to meet blast resistant criteria. Exterior doors are provided with automatic closers and panic hardware as need for code egress compliance. UL-listed interior fire doors are located and installed in conformance to NFPA No. 80, "Fire Doors and Windows."

-Roofing System: Two ply granular surface modified bitumen roof system over a ½-inch glass mat gypsum cover board and five inches of polyisocyanurate insulation.

3544Warehouse (South Annex)1918Yes11,169
3546Warehouse (South Annex)1918Yes11,169
Post 1North Pier Entry DFP2018No
Post 2North Pier Extension DFP2018No
Post 3North Pier Head-In DFP2018No
Post 4South Pier Port Side End DFP2018No
Post 5South Pier Starboard Side End DFP2018No
Post 6South Pier Entry DFP2018No
Post 7South Pier 2314 Security DFP2018No
Post 8South Vehicle Entry Gate DFPNo
Post 9North Vehicle Entry Gate DFPNo

Appendix E - Facility Inventory - RP and Non-RP

&P

FOR OFFICIAL USE ONLY