Atch_3_-_Addendum__1 _Bldg_169.pdf

PDF 156 KB Posted

Attached to
Repair Base Operations/Command Post, Bldg 169 at JB CHS-AB Federal contract opportunity
Solicitation number
FA4418-16-R-0018
Issued by
Department of the Air Force Air Mobility Command

About this file

Atch 3 Addendum 1 B169

View the file

Other files for this federal contract opportunity

Other files attached to Repair Base Operations/Command Post, Bldg 169 at JB CHS-AB, newest first.
File Type Posted
Amendment_0002_-_Crct_CLIN_0003,_B169.pdf PDF
Amendment_0001_-_Adden.__2,_B169.pdf PDF
_2_Qs_&_As,_B169.pdf PDF
Asbuilts,_B169.pdf PDF
_1_Qs_&_As,_B169.pdf PDF
Site_Visit_Brief_Slides_-_B169.pdf PDF
Conf-Site_Visit_Minutes,_B169.pdf PDF
Site_Visit_Attendees_Sign_In_Sheet_-_B169.pdf PDF
Solicitation _Rpr_Base_Ops-Cmd_Post _B169.pdf PDF
Atch_7_-_CLIN_0009_2nd_Flr_Furn._-_TWCF_437th_BO_6.pdf PDF
Atch_11_-_List_of_Furnishings_-_Remove _Dispose _B169.pdf PDF
Atch_7_-_CLIN_0007_1st_Flr_Furn._-_TWCF_628th_BO_4.pdf PDF
Atch_1_-_Specifications _Bldg_169.pdf PDF
Atch_6_-_FF E_Interior_Design_Vol_1 2 _B169.pdf PDF
Atch_7_-_CLIN_0008_2nd_Flr_Furn._-_O M_628th_BO_5.pdf PDF
Atch_7_-_CLIN_0006_1st_Flr_Furn._-_TWCF_437th_BO_3.pdf PDF
Atch_7_-_CLIN_0004_1st_Flr_Furn._-_Jt_628th _437th_BO_1.pdf PDF
Atch_2_-_Drawings _Bldg_169.pdf PDF
Atch_4_-_Drawing _Roof_Assesment.pdf PDF
Atch_7_-_CLIN_0005_1st_Flr_Furn._-_O M_437th_BO_2.pdf PDF
Atch_12_-_AF_BPAs_Contracts_Furnishings_Info _FF E _B169.pdf PDF
Atch_9 _Green_Procurement _B169.pdf PDF
Atch_8_-_Submittal_Register _B169.pdf PDF
Atch_5_-_Photos_of_Roof_Sections.pdf PDF
Atch_10_-_WD_SC30_Charleston_Co._8.26.16 _B169.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Addendum #1

FA4418-17-R-0001

Project: DKFX 14-1042/D

Repair Base Ops/Command Post, Bldg 169

Joint Base Charleston - Air Base, SC

28 September 2016

1. Drawings, Sheet A102, Admin Room 224: All existing fixtures, furnishings and equipment

(FF&E) in this area will be reused by the building occupants after construction is complete.

With the exception of the TV Wall and two wall-mounted flat-screen monitors, the Contractor shall remove, store and reinstall the FF&E, as part of CLIN 0001. The Contractor shall protect the TV Wall and both wall-mounted flat-screen monitors throughout the duration of the contract as part of CLIN 0001.

FF&E to be stored and reinstalled include 34 conference chairs, 1 large conference table, 3 workstations, 4 wall mounted storage cabinets, 2 framed prints, 1 work table, 1 - 25 cf refrigerator, and 2 – 3.5 cf refrigerators.

2. Drawings, Sheet A102, Admin Room 231: All existing fixtures, furnishings and equipment

(FF&E) in this area except the server rack connected/networked to the TV Wall in Room 224 will be removed by the Government prior to construction. The server shall remain de-energized for the duration of the contract. The Contractor shall protect the server throughout the duration of the contract as part of CLIN 0001.

3. Drawings, Sheet A102, Server Room 241: All existing fixtures, furnishings and equipment

(FF&E) in this area (server racks and telephone panels) shall remain in-place, in a de-energized state, for the duration of the contract. The Contractor shall protect this equipment throughout the duration of the contract as part of CLIN 0001.

4. Drawings, Sheet A611, Door Tag 213: Change door material from wood to hollow metal and finish from stain to PNT-6.

5. Exterior Signage Metal Painting: The Contractor shall repaint the frame of the existing exterior building identification sign (approximately 60 square feet) in accordance with

Specification Section 09 90 00 as part of CLIN 0001. New signage is not required.

6. Specification 01 57 50 Temporary Environmental Controls: Storm Water Pollution Prevention Plan

(SWPPP) is not required for this project. Delete paragraph 1.5.d.4. Delete “or as specified in the approved

Construction Stormwater Pollution Prevention Plan (SWPPP)” within paragraph 3.3.3. Delete paragraphs

3.4.1 and 3.4.2.

7. Submittal Register: Delete requirement for Storm Water Pollution Prevention Plan compliance notebook per 01 57 50 paragraph 3.4.2.

8. Specifications Table of Contents: Add Section 23 09 23.13 20 BACnet DIRECT DIGITAL

CONTROL SYSTEMS FOR HVAC to Table of Contents.

- End -

File details come from the government source that posted it. Updated .