Attachment 03 - Drawings Repair Sewer Lines Basin 2 FY24-C102.pdf
PDF 344 KB Posted
- Attached to
- Civil Works IDIQ 2024 - Hurlburt Field, FL
- Solicitation number
- FA441724CivilWorks
About this file
This document is a drawing titled "Repair Sewer Lines, Basin 2" related to a federal contract opportunity for a Civil Works IDIQ contract at Hurlburt Field, FL. The drawing provides details on the planned sewer line repairs, including the installation of approximately 400 linear feet of 10-inch PVC sewer line, a new manhole, and connections to existing sewer lines. The federal contract opportunity is a multi-award IDIQ contract for general construction requirements at Hurlburt Field, with a guaranteed minimum of $25,000 and a maximum ceiling of $26,000,000. The repair of the sewer lines in Basin 2 is identified as the "seed project" for this IDIQ, with an estimated value between $250,000 and $500,000. The contract is set aside for 100% small businesses under NAICS code 237310. A site visit for the seed project is scheduled for March 20, 2024, and proposals are due by a date specified in the solicitation.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S
S S
S S
S S
S S
S S
S S
S S
S S
SS
SS
SS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S
S S
S S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S W
SW
S W
S W
S W
S W
S W
S W
S W
S W
S W
S W
S
W
S
W
S
W
S
W
S
W
S
W
S
W
S
W
S
W
S W
S W
S
W
S
W
S
W
S W
S W
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
S
W
S W
S S
S S
S S
S S
SS
SS
S S
S S
S S
SS
SS
S S
S S
S S
S S
SS
SS
S S
S S
S S
S S
SHEET REFERENCE:
DA
TE
SHEET NUMBER:
OF
DE
SC
RI
PT
IO
N
RE
V
AI
R
FO
RC
E
SP
EC
IA
L
OP
ER
AT
IO
NS
C
OM
M
AN
D
SP
EC
IA
L
OP
ER
AT
IO
NS
C
IV
IL
E
NG
IN
EE
R
SQ
UA
DR
ON
HU
RL
BU
RT
F
IE
LD
, F
LO
RI
DA
PROJECT NUMBER:
BUILDING NUMBER:
DRAWN BY:
DESIGNED BY:
DATE:
IA
R
E
OF RC
SPE
C
IA
AN
N
PE
R L O
ATI
O
MM
SC
O
D
12 DEC 23
R E
P A
I R
E W
E
L
N
E S
B
A S
N
H U
R L
B U
T
F
E
L D
F
L
KEG
KEG
CP 1139009
A
PR
C1
R
EV
IS
ED
A
RR
OW
, C
2 R
EV
IS
ED
S
IZ
E
OF
P
IP
E
C202
UT
ILI
TY
S
IT
E
PL
AN
M H
7- 6 T
O
MH
7-
MH 7-20
T.E. = 35.77'
I.E. (B90815) = 29.62'
I.O. =29.62'
INSTALL 10" PVC SEWER LINE WITH 45
DEG COUPLING INTO MH 7-20
SS
SS
NEW SANITARY SEWER LINE
SANITARY SEWER LINE
UNDERGROUND FIBER OPTIC LINE
ELECTRICAL LINE
FENCE
GAS LINE
COMM LINE
WATER LINE
SANITARY SEWER MANHOLE
NEW ASPHALT PAVEMENT
NEW CONCRETE SLABS
ABANDONED UTILITY LINE
GRASS
Feet
0 10 20
R50'
R50'
R50'
INSTALL MANHOLE WITH
HD RATED MANHOLE TOP,
FRAME, AND COVER, SEE
DETAIL A ON SHEET C203
NEW MH 7-6
T.E. = 35.75'
I.O. = 30.35'
I.E. (MH 7-3) = 30.43'
I.E. (MH 7-26) = 30.58'
I.E. (B90816) = 30.55'
CONNECT
EXISTING 6" PVC
AND 8" PVC
SEWER LINES TO
NEW MH 7-6
AutoCAD SHX Text
10" PVC
AutoCAD SHX Text
10" PVC
AutoCAD SHX Text
6" PVC
AutoCAD SHX Text
8" PVC
AutoCAD SHX Text
6" CIP
AutoCAD SHX Text
10" PVC
AutoCAD SHX Text
15" CMP
AutoCAD SHX Text
8" CIP
AutoCAD SHX Text
6" PVC
AutoCAD SHX Text
40"X60" ECMP
AutoCAD SHX Text
12" CMP
AutoCAD SHX Text
10" PVC
AutoCAD SHX Text
6" PVC
AutoCAD SHX Text
40"X60" ECMP
AutoCAD SHX Text
40"X60" ECMP
AutoCAD SHX Text
ABND 8" VCP
AutoCAD SHX Text
10" PVC
AutoCAD SHX Text
UNDERGROUND UTILITY LINETYPE LEGEND:
AutoCAD SHX Text
UNDERGROUND UTILITY LINETYPE LEGEND:
AutoCAD SHX Text LAYOUT SIZE 22"x34"
AutoCAD SHX Text
SCALE 1" = 10'
| Sheets and Views |
| C202 |
File details come from the government source that posted it. Updated .