SOF MTF Heat Map.pdf

PDF 1021 KB Posted

Attached to
Generation II Wireless for SOF Maintenance Training Facility on Hurlburt Field, FL. Federal contract opportunity
Solicitation number
FA441723Q00081
Issued by
Department of the Air Force Special Operations Command

View the file

Other files for this federal contract opportunity

Other files attached to Generation II Wireless for SOF Maintenance Training Facility on Hurlburt Field, FL., newest first.
File Type Posted
RFQ FA441723Q0008 (Revised).docx DOCX document
RFQ FA441723Q0008 (Revised).docx DOCX document
Desired Wireless Coverage Area SOF MTF.pdf PDF
SOF MTF Drawings.pdf PDF
RFQ FA441723Q0008.docx DOCX document
SOW Wireless SOF Maintenance Training Facility 03 Apr 2023.pdf PDF
Aruba Brand Name Justification-FA441723Q0008 one.pdf PDF
SCA WD 2015-4531 Rev 22 27 Dec 22.pdf PDF
FA411723Q0008-List of Parts and Materials.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Predictive Heat Map

Wi-Fi Network Report for SOF Maintenance Training Classroom

This desktop wireless design was developed based on information provided by the customer with access points and air monitors placed per the customer’s coverage area(s) and BITI design requirements. Some assumptions were made such as wall types and as such heat map depictions are reflective of those assumptions.

NOTE: Final design and placement of devices is subject to the integrators discretion and recommendations.

Floor 1

Access Points on Floor 1

Signal Strength for Floor 1 Signal Strength - sometimes called coverage - is the most basic requirement for a wireless network. As a general guideline, low signal strength means unreliable connections, and low data throughput.

2.4 GHz

Signal Strength for Floor 1

5 GHZ

Access Points Summary

SOF Maintenance Training Classroom - Floor 1 Name AP Model Simulated AP-2 Aruba AP-225

Simulated AP-3 Aruba AP-225

Simulated AP-4 Aruba AP-225

Simulated AP-5 Aruba AP-225

Simulated AP-6 Aruba AP-225

Simulated AP-7 Aruba AP-225

Total APs for SOF Maintenance Training Classroom - Floor 1 =

Air Monitors on Floor 1

IDS/IPS (Air Monitor) Signal Strength for Floor 1

Air Monitor Summary

SOF Maintenance Training Classroom - Floor 1 Name Model Simulated AP-1 Aruba AP-225

Simulated AP-8 Aruba AP-225

Total AMs for SOF Maintenance Training Classroom - Floor 1 = 2

AP and AM Total

SOF Maintenance Training Classroom Simulated AP-1 Aruba AP-225

Simulated AP-2 Aruba AP-225

Simulated AP-3 Aruba AP-225

Simulated AP-4 Aruba AP-225

Simulated AP-5 Aruba AP-225

Simulated AP-6 Aruba AP-225

Simulated AP-7 Aruba AP-225

Simulated AP-8 Aruba AP-225

Total APs for SOF Maintenance Training Classroom =

Caveats

• This design is a prediction only; no formal visit was performed to determine additional interferers.

• Inner wall construction was estimated as thicker walls being all concrete and smaller walls were assigned as drywall.

• This plan is for coverage and not capacity. There are many ways to plan a deployment, capacity, coverage and speed. In this case Aruba predicted for at least -75dBm in all areas.

• Additional interferers that may cause issues could be, additional walls not show in drawings, additional furniture not shown in drawings (minimal unless it’s large i.e. large metal filling cabinets), microwave ovens, plants, water pipes in the walls, wall mounted TVs in each room, etc…

• Microwave ovens, wireless capable TVs or projectors, wireless handsets, water pipes, trees and plants can all be interferers to the WLAN should these be identified this projection can be re-run.

• If the wall construction assumptions were incorrect, this prediction can be re-run with the appropriate values.

• It may be worth a full ACTIVE site survey once the deployment is completed to get a more accurate projection of coverage and define if there are additional APs required.

Access Points on Floor 1
Air Monitors on Floor 1
Caveats