SCALE: 3/32" = 1'-0"
6'-
8"
108'-0"
89'-4"
7'- 6"
7'- 8"
6'-0"
MA
IN
TA
IN
5' -0
CL
EA
R
MAINTAIN 9'-2"
CLEAR
DOOR IDENTIFICATION,
SEE DOOR SCHEDULE SHEET A-601.
NEW METAL STUD PARTITION,
SEE WALL TYPES SHEETS A-XXX
ROOM IDENTIFICATION
W1 WALL TYPE, SEE DETAIL 1/A-310
1. ALL DIMENSIONS TO NEW PARTITION/WALL CONSTRUCTION ARE
FROM FINISH FACE OF EXISTING CONSTRUCTION TO FACE OF
NEW STUD, UNLESS NOTED OTHERWISE.
8'-0" 15'-4" 6'-6"
8'- 0"
MA
IN
TA
IN
1' -2
CL
EA
R
EXISTING RAIN LEADER PIPE, TO REMAIN.1
PROVIDE TEMPORARY DIVIDER WALL IN RECEIVING/PREP.
DURING CONSTRUCTION. WALL TO BE 8' HIGH, CONSTRUCTED OF
2X4 WOOD STUDS @ 24" O.C. WITH 1/2" PLYWOOD SHEATHING ON
ONE SIDE, BRACE AS NEEDED. WALL TO BE REMOVED AFTER
CONSTRUCTION HAS BEEN COMPLETED. ANY DAMAGE TO
EXISTING FLOOR/WALL SURFACES THAT OCCURS DURING
CONSTRUCTION AND/OR REMOVAL OF THIS TEMPORARY WALL
WILL BE REPAIRED BY THE CONTRACTOR.
TEMPORARY WOOD DOOR WITH WOOD FRAME, TO REMAIN IN
PLACE AND UNLOCKED DURING THE TIME THAT THE
TEMPORARY DIVIDER WALL IS IN PLACE. PROVIDE PANIC BAR
AND PASSAGE HARDWARE. DOOR IS REQUIRED TO AVOID
BLOCKING ANY LIFE SAFETY EXIT PATH OF TRAVEL.
LOCATE TEMPORARY DIVIDER WALL TO AVOID ANY ADJACENT
WALL MOUNTED ITEMS IN THIS AREA.
32 GALLON GFGI PLASTIC WASTE BIN.
4'-0"w x 7'-4"h MASONRY OPENING. SEE DETAILS 5/A601 & 6/A601
PROVIDE ONE (1) SET WEATHERSTRIPPING 303AV,
THRESHOLD NGP # 896 ADN SWEEP 315AN AT 3'-0" x 7'-0" DOOR
AND FRAME.
PROVIDE SIGN TYPE 'B' AT THIS LOCATION
PROVIDE LIGHTED EXIT SIGN ABOVE TEMPORARY DOOR, SEE
ELECTRICAL DOCUMENTS.
W1
W1
W1
W1
A-
NORTH
AREA 'A'
111B
TD1
111A
8 8
8 8
SCALE: N.T.S.
" M
AX
. A
.F .F
" M
AX
. A
.F .F
3"
IT/COMM
SCALE:
SIGN TYPE B
3" = 1'-0"
3 1 /2"
8 1/2"
1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE
QUANTITY OF SIGNS REQUIRED PER MARK.
2. SIGNS SHOULD BE LOCATED ON THE LATCH SIDE OF THE DOOR
AND MOUNTED ON THE ADJACENT SURFACE AS SHOWN IN THE
SIGN MOUNTING TYPICAL ON THIS SHEET. SIGNS AT DOUBLE
DOORS WITH TWO ACTIVE LEAFS SHALL BE LOCATED TO THE RIGHT
OF THE RIGHT HAND DOOR. IF ONE LEAF IS INACTIVE THEN THE
SIGN SHOULD BE MOUNTED ON THE DOOR.
3. SIGNAGE SHALL COMPLY WITH THE CURRENT UFC 3-120-01 DESIGN:
SIGN STANDARDS AND ABA GUIDELINES.
4. ALL SIGNAGE TEXT SHOULD BE CONFIRMED WITH THE USER PRIOR
TO ORDERING.
5. THE DESIGN AND CONSTRUCTION OF THE INTERIOR ROOM
SIGNAGE, SHALL BE BASED ON TAKEFORM VIVID OR EQUIVALENT.
INTERIOR SIGNS SHALL BE MOUNTED WITH ADHESIVE STRIPS.
6. REFER TO UFGS 10 14 00.20 INTERIOR SIGNAGE.
R E
P A
IR
C
O R
R O
S
IO
N C
O N
TR
O
L
FA
C
IL
IT
Y
90225
B U
IL
D
IN
G
/08 /20
AD
DE
ND
UM
#1
/14
/20
AD
DE
ND
UM
#2