Design Layout-Camera and Monitor locations.pdf
PDF 226 KB Posted
- Attached to
- Closed Circuit Television (CCTV) Installation
- Solicitation number
- FA440726Q0009
About this file
This document is a facility security specification for AMC-Scott-679, Building 5028A, detailing communications equipment placement and security system requirements across two areas.
Foyer (Building 5028A): The foyer contains multiple wireless communications devices including a Wireless Access Point (WAP), cell phones, LMR radios, wireless laptops/tablets, and personal electronic devices (smart watches, key fobs). All communications equipment within 5 meters of the CPA/CAA (Controlled and Contaminated Access) boundary has been identified and maintains a minimum 3-meter separation from RED equipment to prevent electromagnetic interference.
Room 104 (Building 5028A): Room 104 requires a projected new installation of a CCTV controller with two monitors positioned on opposite sides of a wall for viewing purposes, and a WYSE terminal station for access badge creation. The room also contains two safes. RED and BLACK equipment separation requirements per ESIM 2010-02 include: minimum 5cm separation between RED and BLACK monitors, 0.5m separation between RED monitors and BLACK equipment (and vice versa), and 0.5m separation between RED and BLACK equipment generally. The RED and BLACK laptop is built without wireless, camera, and microphone capabilities. The document includes architectural floor plans, equipment legends, and photographs documenting the facility layout and designated camera placement locations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bldg. 5028A, FoyerAMC-Scott-679
Wireless Access Point (WAP) Cell Phone
LMR Radio
Wireless Laptop &/or Tablet PED (Smart Watch, key FOB, etc) *All communications equipment within 5m of CPA/CAA boundary have been identified on this floor & maintain a minimum separation of 3 meters from RED equipment.
Safe
AMC-Scott-679 Bldg. 5028A, Room 104
Projected new install -- CCTV controller and 2 monitors for viewing one on each side of the wall WYSE terminal station for making access badges
Safe
*RED & BLACK monitors maintain a minimum of 5cm separation IAW ESIM 2010-02.
*RED monitors maintain 0.5m separation from BLACK equipment & vice versa IAW ESIM 2010-02.
*RED & BLACK equipment maintain a minimum of 0.5m separation.
*RED & BLACK laptop built without wireless, camera & microphone.
Room 104
Facing south with the glass “front” double door to the right and wooden security door entering our facility to the left
Facing north (by the logo) and east (the glass back door)
Facing west with a view of the corner where camera 2 should go
| Slide Number 1 |
| Slide Number 2 |
| Slide Number 3 |
File details come from the government source that posted it. Updated .