RFI Q and A.pdf

PDF 61 KB Posted

Attached to
Scott AFB Office Furniture Federal contract opportunity
Solicitation number
FA440721QSL01
Issued by
Department of the Air Force Air Mobility Command

View the file

Other files for this federal contract opportunity

Other files attached to Scott AFB Office Furniture, newest first.
File Type Posted
Brand Name Justification.pdf PDF
Attachment 1 Pricing Worksheet.xlsx XLSX spreadsheet
FA440721Q0002 - P4 Furniture RFQ - 24 May 21.pdf PDF
Attachment 2 NATIONAL DEFENSE AUTHORIZATION ACT SECTION 889 CERTIFICATION FORM Soliciation.pdf PDF
P4 Furniture - SOW Final 18 May 21.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions Answers Date Received Date sent to Customer Date Answered

2‐Jun‐21 2‐Jun‐21 3‐Jun‐21

1. There are a few workstations that a monitor arm may not fit on the workstation (please reference attached drawings). For example: Room 007 (only has 84”W surface w/ overhead) & Rm 115 (51”w surface & overhead because of column). Is the quantity of monitor arms accurate at (97) monitor arms for all locations with possibly 2 locations that they may not fit or may not work with the overheads and layout?

(97) monitor arms priced each, with a caveat of the possibility that (2) locations will not be able to accommodate due to layout limitations.

2‐Jun‐21 2‐Jun‐21 3‐Jun‐21

2. We have the same total quantity of workstations from what the SOW calls out (last attachment – page 11).

However, Rooms 102 & Rooms 104 are a bit different. Their total count in Room 102 is (26) & we have (25). Total count for room 113 is (1) but we are showing “no change” in this room. Please advise if the layout needs to be reconfigured.

Is there a change to the layouts in rooms 102 and 104? Additional workstations in each would be difficult to fit so we will need to review what is desired if there is a layout change.

No change; clarification: The areas in green in the SOW are areas to be changed. The current number of workstations is (20) in Room 102. The requirement is to increase to (25) workstations with (1) of them being a private office. The current number of workstations is (10) in Room 113.

The requirement is to increase to (11) workstations. The currernt number of workstations is (4) in Room 104 with (2) behind a sliding door.

The requirement is to add one workstation that is not within the sliding door spaces and to make the sliding door to the (2) workstations 78" height.

2‐Jun‐21 2‐Jun‐21 3‐Jun‐21

3. Coat hook and hanger‐ Dividends has a standard coat hook we can price and include. To purchase the hanger would be open market item. Is it alright to add hangers to our bid as an open market item? (CONS) Yes, include pricing for hangers to the bid.