Questions_and_Answers.docx

DOCX document 16 KB Posted

Attached to
Repair Roof B53
Solicitation number
FA3099-18-R-0020
Issued by

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA3099-18-R-0020, Questions and Answers

· Provide clarification on the SOW as there is a references to soffit and did not appear to be any during the site visit.

· SOW mentions soffits as an example only; this roof has no soffits.

· Provide clarification on the SOW as there is a reference to replacing wall panels

· No wall panels are to be replaced.

· In lieu of removal of the existing PBR metal roofing, can we suggest the option to install a retrofit roofing system using roof huggers and new the SSHM system?

· No.

· What exactly are the roofing specifications for this project? Preferred Manufacturer, panel profile and gauge of materials?

· Please see UFC 3-110-03 (Attachment 2), Chapter 5.

· Replacement insulation type and desired R-value?

· Vinyl “Bag and Sag” with minimum R-30 value

· What are the requirements and specifications for the lighting suppression system?

· Assumption: “lighting suppression” is supposed to be “lightning protection”

· Answer: Current lightning protection system can be re-installed.

· Are you wanting a weather tightness warranty? Period of coverage and type?

· Please see SOW section 7.