100_Per_Cent_B448_Drawings_REVISED.pdf
PDF 23 MB Posted
- Attached to
- B448 Replace Air Units and Upgrade EMCS Federal contract opportunity
- Solicitation number
- FA303018B0004
About this file
Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA303018B000400006.pdf | ||
| Record_of_Attendance.pdf | ||
| FA303018B0004_-_amendment_0004.pdf | ||
| Questions_and_Answers.pdf | ||
| 2008_Asbestos_Report.pdf | ||
| 1992_Asbestos_Report.pdf | ||
| FA303018B00040003.pdf | ||
| FA303018B00040002.pdf | ||
| FA303018B00040001.pdf | ||
| WD_TX180336__05_Jan_18.pdf | ||
| Insurance_Requirements.pdf | ||
| FA303018B0004.pdf | ||
| BAL_Request.pdf | ||
| Speicifications_06Jun18.pdf | ||
| AF_66.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
ELECTRICAL
MD-101 MD-101
SCALE: 3/32" = 1'-0"
HVAC DEMO PLAN
MD101MD102
MD102 MD101
MD103 MD101
MD103 MD101
X
X
X
X
X
X
X
X
MD-102 MD-101
SCALE: 1/4" = 1'-0"
ENLARGED MECH ROOM
MECHANICAL DEMOLITION
MD-102 MD-101
SCALE: 1/4" = 1'-0"
AHU-1 ENLARGED PLANS
MECHANICAL DEMOLITION
WH
MD-103 MD-101
SCALE: 1/4" = 1'-0"
AHU-2 ENLARGED PLAN
MECHANICAL DEMOLITION
MD-103 MD-101
SCALE: 1/4" = 1'-0"
AHU-3 ENLARGED PLAN
MECHANICAL DEMOLITION
MD-201 MD-201
SCALE: 3/32" = 1'-0"
HVAC DEMO ROOF PLAN
M-103 M-103
SCALE: 3/16" = 1'-0"
HVAC FLOOR PLAN C
M105 M101
CHWP-1
ZONE 3
M-104 M-104
SCALE: 3/16" = 1'-0"
HVAC FLOOR PLAN D
M101M106
M-105 M-101
SCALE: 1/4" = 1'-0"
AHU-1 ENLARGED PLAN
MECHANICAL NEW WORK
M-105 M-103
SCALE: 1/4" = 1'-0"
AHU-2 ENLARGED PLAN
MECHANICAL NEW WORK
M-105 M-101
SCALE: 1/4" = 1'-0"
AHU-1 SECTION VIEW
MECHANICAL NEW WORK
M-105 M-103
SCALE: 1/4" = 1'-0"
AHU-2 SECTION VIEW
MECHANICAL NEW WORK
KEY NOTES:
M-106 M-104
SCALE: 1/4" = 1'-0"
AHU-3 ENLARGED PLAN
MECHANICAL NEW WORK
M-106 M-104
SCALE: 1/4" = 1'-0"
AHU-3 SECTION VIEW
MECHANICAL NEW WORK
M-201 M-201
SCALE: 3/32" = 1'-0"
HVAC ROOF PLAN
X
X
X
X
X
X
X
X
ELECTRICAL
M-301 M-301
SCALE: 3/32" = 1'-0"
HYDRONIC PIPING PLAN
M-302M-301
GENERAL NOTES:
C W R
C W R
C W R
C W R
C W S
C W R C W R C W R
C W R
C W S C W S C W S
C W R
C W S
C W S
C W S
C W S
X
X
X
X
X
X
X
X
X
X
M-302 M-301
SCALE: 1/4" = 1'-0"
PARTIAL HYDRONIC PIPING PLAN
M-401 M-401
SCALE: N.T.S.
HOT WATER ONE LINE DIAGRAM
M-402 M-402
CHILLED WATER ONE LINE DIAGRAM
M501 M101
SCALE: N.T.S
DUCT TAKEOFF DETAIL
M501 M101
SCALE: N.T.S
CONDENSATE DRAIN TRAP DETAIL
FINISHED FLOOR DETAIL
M501 M101
SCALE: N.T.S
CONNECTION DETAIL
TYPICAL FLEXIBLE DUCT
M501 M101
SCALE: N.T.S
VANE DETAIL
TYPICAL TURNING
M501 M101
SCALE: N.T.S
PIPE PENETRATION DETAIL
THRU WALL
M501 M101
SCALE: N.T.S
AIR INSTALLATION DETAIL
GRID CEILING SUPPLY
M501 M101
SCALE: N.T.S
FOR ROUND / OVAL DUCT
ACCESS SECTION
M501 M101
SCALE: N.T.S
ADJUSTABLE SINGLE BLADE BALANCING TYPE
MANUAL DAMPER
M501 M101
SCALE: N.T.S
RECTANGULAR DUCT
ACCESS SECTION FOR
M
NC
C
M
C
NC
M501 M101
SCALE: N.T.S
FAN COIL INSTALLATION DETAIL
M502 M101
SCALE: N.T.S
VAV BOX DETAIL
SERIES FAN POWERED
M502 M101
SCALE: N.T.S
VAV BOX MOUNTING DETAIL
M502 M101
SCALE: N.T.S
DUCT ACCESS DOOR DETAIL
M502 M101
SCALE: N.T.S
CEILING ACCESS PANEL DETAIL
M502 M301
SCALE: N.T.S
PIPING DETAIL
HYDRONIC COIL
M502 M101
SCALE: N.T.S
REFRIGERANT PIPING DETAIL
DX - SPLIT SYSTEM
UNION
M503 M101
SCALE: N.T.S
BOOT INSTALLATION DETAIL
GRID CEILING RETURN AIR
M503 M101
SCALE: N.T.S
INSTALLATION DETAIL
AHU-1 DUCT
M503 M201
SCALE: N.T.S
PIPE SUPPORT DETAIL
PIPING ROOF PENETRATION
M503 M201
SCALE: N.T.S
INSTALLATION DETAIL
PENTHOUSE LOUVER
M503 M201
SCALE: N.T.S
EXHUAST FAN DETAIL
ROOF MOUNTED CENTRIFUGAL
M504 M401
SCALE: N.T.S
THERMOMETER INSTALLATION
IN INSULATED PIPE
PRESSURE REGULATOR
PRESSURE GAUGE
( 25 PSIG)
( 30 PSIG)
RPBP
DRAIN VALVE
W/HOSE CONNECTION
TO FLOOR DRAIN
1" TO FLOOR DRAIN
FUNNEL DRAIN BELOW
ISOLATION CHAMBER
3/4" BY-PASS
HOSE CONNECTION
3/4"
TO CHILLED WATER
RELIEF SETTING 35 PSI
OR BOILER MAKE-UP
VENT ALL HIGH POINTS INDICATED ABOVE.
WHERE AUTOMATIC AIR VENTS ARE USED, PIPE DISCHARGE
NOTES:
1/4" (8 MM)
COPPER TUBING
1/2" (15 MM)
GATE VALVE
1/2" (15 MM) x 4" (100 MM)
REDUCER
CIRCULATING
1.
2.
NIPPLE
ELEVATION
WATER PIPING
ABOVE 2" (50 MM) DIA. PIPE
2 1/2" (65 MM) DIA.
2" (50 MM) DIA. & SMALLER
HORIZONTAL
ABOVE 2" (50 MM) DIA. PIPE
2" (50 MM) DIA. & SMALLER
VERTICAL
2 1/2" (65 MM) DIA.
TO NEAREST MECHANICAL ROOM DRAIN.
SPECS FOR TYPE AND RANGE
2 BRASS THERMOMETER WELL, SEE DETAIL 7, THIS SHEET.
3 THREADOLET WELDED TO PIPE
4 DEPTH OF WELL ONE-THIRD
OF PIPE DIAMETER
5 PIPE DIAMETER
6 PIPE INSULATION
1 THERMOMETER - SEE
M504 M401
SCALE: N.T.S
INSTALLATION OF
THERMOMETER WELLS
M504 M105
SCALE: N.T.S
MAKE-UP WATER SPOOL DETAIL
M504 M105
SCALE: N.T.S
AIR VENT DETAIL
TYPICAL AUTOMATIC
INSERT TEE HERE FOR
SYSTEM WATER
CONNECTION IF PARALLEL
TANKS ARE USED
VERTICAL
DIAPHRAGM TYPE
EXPANSION TANK
PROVIDE TANK SADDLES &
HANGER ROD SUPPORTS
SEE NOTE 2
AIR VENT
NOTES:
1. DASHED PIPING SHOWS BOTH HORIZONTAL
AND VERTICAL DIAPHRAGM TYPE EXPANSION
TANKS. PROVIDE ONLY THE TYPE OF TANK
SELECTED AND THE ASSOCIATE PIPING.
2. CONNECT TO SIDE OF MAIN TO PREVENT AIR
OR DEBRIS FROM ENTERING PIPE TO TANK,
TOP OR BOTTOM CONNECTION NOT PERMITTED.
3. PROVIDE 12" [305mm] MINIMUM DROP
ANTI-THERMOSYPHON LOOP TO PREVENT
GRAVITY HEATING OF TANK.
4. SEE EXPANSION TANK SYSTEM SCHEDULE FOR
COMPONENT SIZES.
5. RELIEF VALVE FOR CONDENSER WATER SYSTEM
IS SHOWN. OMIT WHEN RELIEF VALVE IS
SHOWN ON HEAT EXCHANGER DETAIL &
SYSTEM IS USED ONLY FOR HOT WATER
HEATING. COMBINATION HEATING & COOLING
SYSTEMS WILL REQUIRE THE RELIEF VALVE.
6. PROVIDE STRAINER IN AIR SEPARATOR WHEN
INDICATED IN EXPANSION TANK SCHEDULE.
7. SET PRESSURE REDUCING VALVE SO
PRESSURE AT HIGHEST POINT IN SYSTEM HAS
A MINIMUM OF 4 PSIG. [28kPa]
HORIZONTAL
DIAPHRAGM TYPE
EXPANSION TANK
MANUAL AIR VENT
INSERT TEE HERE FOR
SYSTEM WATER
CONNECTION IF PARALLEL
TANKS ARE USED
INTEGRAL FULL
PORT FLOAT
ACUTATE
BRASS VENT
MECHNISM
RUN DRAIN LINE TO
NEAREST FD UNLESS
INDICATED OTHERWISE
COMBINATION AIR
DIRT SEPARATOR
M504 M105
SCALE: N.T.S
FOR CHILLED WATER AND HEATING HOT WATER SYSTEMS
AIR CONTROL AND PIPING CONNECTIONS
FLUSH VALVE
M I N
FLUE VENT(REFER
ARCH. DRWGS.)
AGA APPROVED
VENT CAP
FLUE SIZE IAW
MANUF. REQMTS.)
M504 M105
SCALE: N.T.S
CHEMICAL FEEDER DETAIL
M504 M401
SCALE: N.T.S
FLUE VENT DETAIL
TYPICAL STRUCTURAL STEEL
MEMBER FOR EQUIPMENT
NUMBER OF SPRING ISOLATION
UNITS AS REQUIRED
STRUCTURAL
STEEL FRAME
SPRING
ISOLATOR
ANCHOR
BOLT
REINFORCING
BARS
SLEEVE
#6 BAR ON
8" CENTERS NOM.
BOTH WAYS
ALL WELDED
STEEL FRAMEWORK
3000 PSI
CONCRETE INFILL
SECTION "A-A"
M504 M302
SCALE: N.T.S
ISOLATION DETAIL
PUMP VIBRATION
M504 M302
SCALE: N.T.S
ISOLATION DETAIL
VIBRATION
NEOPRENE
PAD
STEEL
SPRING
VIBRATION
ISOLATOR
CONCRETE
FLOOR
5/8"∅
ANCHOR
BOLT
EQUIPMENT
NEOPRENE
PAD
PRESSURE GAGE
(0 - 150 psig)
1/4" UNION
1/4" BRASS
NIPPLES
1/4" BALL
VALVE
BUSHING
FITTING
M504 M402
SCALE: N.T.S
INSTALLATION DETAIL
PRESSURE GAUGE
1. PROVIDE REHEAT, INFARED HUMIDIFICATION, LARGE DISPLAY, WATER LEAK DETECTION
CABLE, SMOKE DETECTOR, LOCKING DISCONNECT, CONDENSATE PUMP, AND MERV 8 FILTER.
NOTES:
2.01SYS SCOP
WEIGHT (LBS)
PFH014A-PLNMODEL
LIEBERTMANUFACTURER
B A
S I S
15MOCP
9.1MCA
208/1/60VOLTS/PHASE/HERTZ
E L E
C T
R I C
105AMBIENT AIR
CU-1MARK
G E
N
O U
T D
O O
R
U
N I T
NOTES
WEIGHT (LBS)
MMD12ENXHE02MODEL
LIEBERTMANUFACTURER
B A
S I S
30MOCP
21.3MCA
277/1/60VOLTS/PHASE/HERTZ
E L E
C T
R I C
0.88
HUMIDIFER (KW)
2.5
HUMIDIFIER (LB/HR)
4.8
TOTAL HEATING (KW)
M I S
C
LEAVING AIR TEMP. DB/WB (F)
ENTERING AIR TEMP. DB/WB (F)
12.1SENSIBLE COOLING (MBH)
13.7TOTAL COOLING (MBH)
C O
O L I N
G
C
O I L
0.2MOTOR HP
600SUPPLY AIR (CFM)
57B37ASERVES
MS-2MS-1MARK
G E
N E
R A
L
I N
D O
O R
U
N I T
1.68
LIEBERT
15.4
208/1/60
CU-2
MMD24ENXHED3
LIEBERT
29.7
277/1/60
1.5
4.3
6.3
19.5
21.8
0.5
PFH027A-PHN
8.
M701 M701
SCALE: N.T.S
VARIABLE AIR VOLUME AIR HANDLING UNIT CONTROL DIAGRAM
RELIEF AIR
D-3
D-2
P R E
F I L T E R
OUTSIDE
AIR
D-1
C O I L
P R E H E A T
C O I L
C O O L I N G
LOCATE SENSOR
OUTSIDE UNDER
SHIELD
MPS
V-2
V-1
CHR
CHS
SUPPLY FAN
A F M D
SUPPLY AIR TO
TERMINAL UNITS
TT
TT
TT TT
FT
A F T E R
F I L T E R
TT
HS
CS
VFD
SD
HOT WATER
COIL
PRESSURE SWITCH HIGH
TO DISABLE FAN WHEN HIGH
PRESSURE LIMIT SETPOINT IS
REACHED
PSH
SMOKE
DETECTOR
VARIABLE
FREQUENCY DRIVE,
TYP.
ZC
ZC
ZC
DPS DPS
TT
SST
SPD
TSL
SPS
SD
SD
SEQUENCE OF OPERATION:
S/A
HWS
HWR
F I L T E R
R/A OR
RECIRCULATED
SOUND
BAFFLE
FAN
FT
T
TT
M
SST
PC
ROOM
THERMOSTAT/SENSOR
WALL MOUNTED 48"
[1200 MM] AFF.
FAN POWERED/VARIABLE AIR VOLUME,
AIR TERMINAL UNIT
V-X
M701 M701
SCALE: N.T.S
CONTROL DIAGRAM
FPB/VAV AIR TERMINAL UNIT
SEQUENCE OF OPERATION(CONT.):
GAFB
B448
B448
PUMPS
CHWP-1,2
HWP-1,2
GAFB
B448
B448
FCU-1
M702 M702
SCALE: N.T.S
FOUR PIPE FAN COIL UNIT
D-1
ZC
NOT TO SCALE
Y Z
TITLE
X
X
X
X
X
X
X
X
ED-201 ED-201
SCALE: 3/32" = 1'-0"
ELECTRICAL POWER PLAN - DEMO
ED-202ED-201
HWP-1
ACC-1
X
X
X
X
X
X
X
X
X
X
HWP-2
CHP-1 CHP-2
ED-202 ED-201
SCALE: 1/4" = 1'-0"
PARTIAL ELECTRICAL POWER PLAN - DEMO
EF-1
EF-2
EF-4
EF-5
EF-7
EF-8
EF-9
EF-3
EF-6
EF-4
EF
MAU-1
CU CU CU
ED-203 ED-203
SCALE: 3/32" = 1'-0"
ROOF POWER PLAN - DEMO
ED-301 ED-301
SCALE: NTS
PARTIAL ELECTRICAL ONE LINE DIAGRAM - "SWBD-HMP" - DEMO
ED-302 ED-302
SCALE: NTS
PARTIAL ELECTRICAL ONE LINE DIAGRAM - "SWBD-HMP" - DEMO
ED-303 ED-303
SCALE: NTS
PARTIAL ELECTRICAL ONE LINE DIAGRAM - "SWBD-LMP" - DEMO
ED-304 ED-304
SCALE: NTS
PARTIAL ELECTRICAL ONE LINE DIAGRAM - "SWBD-LMP" - DEMO
X
X
X
X
X
X
X
X
E-201 E-202
SCALE: 3/32" = 1'-0"
ELECTRICAL POWER PLAN
E-202E-201
X
X
X
X
X
X
X
X
H W S
H W S
H W S
E-202 E-201
SCALE: 1/4" = 1'-0"
PARTIAL ELECTRICAL POWER PLAN
E-203 E-203
SCALE: 3/32" = 1'-0"
ROOF POWER PLAN
E-301 E-301
SCALE: NTS
PARTIAL ELECTRICAL ONE LINE DIAGRAM - "SWBD-HMP"
E-302 E-302
SCALE: NTS
PARTIAL ELECTRICAL ONE LINE DIAGRAM - "SWBD-HMP"
E-303 E-303
SCALE: NTS
PARTIAL ELECTRICAL ONE LINE DIAGRAM - "SWBD-LMP"
E-304 E-304
SCALE: NTS
PARTIAL ELECTRICAL ONE LINE DIAGRAM - "SWBD-LMP"
E-501 E-501
FIRE STOP DETAIL
EG-101 EG-101
SCALE: 3/32" = 1'-0"
LIGHTNING PROTECTION PLAN
NON SPRINKLERED SPACE
BUTTERFLY VALVE
OUTSIDE SCREW AND YOKE VALVE
OUTSIDE SCREW AND YOKE NORMALLY CLOSED VALVE
WET PIPE SPRINKLER RISER
BACKFLOW PREVENTER FLOW TEST CONNECTION
SIAMESE FIRE DEPARTMENT CONNECTION
OS& Y
NC OS& Y
APPLICABLE CODES AND STANDARDS:
THE DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE FOLLOWING CODES AND
STANDARDS, AND REFERENCED CODES AND STANDARDS THEREIN;
NFPA 1, FIRE CODE, 2015 EDITION
NFPA 3, RECOMMENDED PRACTICE FOR COMMISSIONING OF FIRE PROTECTION AND LIFE SAFETY
SYSTEMS, 2015 EDITION
NFPA 4, STANDARD FOR INTEGRATED FIRE PROTECTION AND LIFE SAFETY SYSTEM TESTING, 2015
EDITION
NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2013 EDITION
NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2013 EDITION
NFPA 25, STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER-BASED FIRE
PROTECTION SYSTEMS, 2014 EDITION
NFPA 70, NATIONAL ELECTRIC CODE, 2014 EDITION
NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2013 EDITION
NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATION SYSTEMS, 2015 EDITION
NFPA 101, LIFE SAFETY CODE, 2015 EDITION
NFPA 170, STANDARD FOR FIRE SAFETY AND EMERGENCY SYMBOLS, 2015 EDITION
NFPA 291, RECOMMENDED PRACTICE FOR FIRE FLOW TESTING AND MARKING OF HYDRANTS, 2013
EDITION
ABA ACCESSIBILITY STANDARD FOR DEPARTMENT OF DEFENSE FACILITIES AS SIGNED AND
ADOPTED BY THE DEPUTY SECRETARY OF DEFENSE MEMORANDUM DATED 0CTOVER 31, 2008
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES, 26 SEPTEMBER 2006 CHANGE 3, 1
MARCH 2013
UFC 3-601-2 OPERATION AND MAINTENANCE: INSPECTIONS, TESTING, AND MAINTENANCE OF FIRE
PROTECTION SYSTEMS, 2010 EDITION
ADDRESSABLE MANUAL PULL STATION
ADDRESSABLE CONTROL MODULE
HEAT DETECTOR (FIXED TEMPERATURE)
PHOTOELECTRIC SMOKE DETECTOR
DUCT DETECTOR
SMOKE DETECTOR WITH SOUNDER BASE
COMBINATION SMOKE AND CARBON MONOXIDE DETECTOR
SMOKE DETECTOR ASSOCIATED WITH CLEAN AGENT SYSTEM
FLOW SWITCH
PRESSURE SWITCH ( AP- ALARM PRESSURE; PS-PRESSUE SUPERVISORY)
TAMPER SWITCH
KITCHEN HOOD SUPPRESSION SYSTEM
KNOX BOX
STROBE LIGHT-WALL MOUNTED (CD-CANDELA RATING; C-CLEAR, A-AMBER)
STROBE LIGHT-CEILING MOUNTED (CD-CANDELA RATING; C-CLEAR, A-AMBER)
HORN (FL-FLASHING LIGHT)
SPEAKER NOTIFICATION APPLIANCE
FIRE ALARM BELL
COMBINATION SPEAKER/STROBE LIGHT APPLIANCE. (CD-CANDELA RATING; C-CLEAR, A-AMBER)
EMERGENCY TEXT MESSAGE
FIRE ALARM CONTROL PANEL
AUTONOMOUS CONTROL UNIT
LOCAL OPERATING CONSOLE
DIGITAL RADIO COMMUNICATOR / TRANSMITTER
ALPHA-NUMERIC ANNUNCIATOR
NOTIFICATION CIRCUIT POWER BOOSTER PANEL
ULTRASENSITIVE SMOKE DETECTION CONTROLLER
POWER BOOSTER SUPPLY
FIRE ALARM LEGEND
ADDRESSABLE MONITOR MODULE
FIRE SPRINKLER
1. REPLACE ALL FIRE SPRINKLERS WITH ALL NEW QUICK RESPONSE SPRINKLERS.
2. THE FOLLOWING STAKEHOLDERS SHALL BE INVITED TO ALL FIRE SUPPRESSION ACCEPTANCE
TESTING: 17 CES FIRE ALARM TECHNICIANS, 17 CES PLUMBERS, 17 CES FIRE PREVENTION OFFICE.
GENERAL NOTES:
FIRE ALARM
1. SCOPE OF WORK IS TO:
1.1. DEMOLISH EXISTING FIRE ALARM SYSTEM AND PROVIDE A NEW FIRE ALARM SYSTEM:
A. DEMOLISH EXISTING HORN/LIGHTS, PULL STATIONS, AND DUCT DETECTORS
B. PROVIDE NEW FIRE ALARM CONTROL PANEL IN CONDITIONED SPACE
F. PROVIDE MANUAL PULL STATIONS NO MORE THAN 48" AFF
G. PROVIDE NEW DUCT TYPE SMOKE DETECTORS WITH REMOTE, KEYED, TEST STATIONS TO INITIATE A
SUPERVISORY ALARM
2. THE FIRE ALARM SYSTEM SHALL BE INSTALLED AND TESTED PER ALL CODES AND STANDARDS REFERENCED
HEREIN. ADDITIONAL LOCAL STANDARDS, ORDINANCES AND POLICIES WILL BE FOLLOWED.
3. REQUIRED EQUIPMENT INCLUDE MONACO MAAP PANEL, NARROWBAND COMPATIBLE WITH A MONACO D-700, OR
MONACO D-21 SYSTEM. ALL DEVICES SHOULD BE ADDRESSABLE TO TRANSMIT EXACT LOCATION AND DEVICE TO
THE MAIN CONTROL PANEL AT GOODFELLOW FIRE DEPARTMENT.
4. FIRE ALARM SYSTEM WIRING: ALL WIRING TO BE FPLR RATED. WIRING SHALL BE PROTECTED FROM PHYSICAL
DAMAGE AS REQUIRED BY UFC 3-600-01 AND NFPA 70. WIRE AND CABLE SHALL BE: POWER LIMITED CLASS "B"
STYLE C FOR THE INITIATING DEVICE AND SIGNALING LINE CIRCUITS AND POWER LIMITED CLASS "A" STYLE Z FOR
THE NOTIFICATION APPLIANCE CIRCUITS. WIRE TYPE SHALL BE LISTED FOR ITS INTENDED USE BY AN APPROVAL
AGENCY ACCEPTABLE TO THE LOCAL AUTHORITY AND SHALL BE INSTALLED IN ACCORDANCE WITH UFC 3-600-01, AND NFPA 70: NATIONAL ELECTRIC CODE. WIRING TO BE SIZED, COLOR CODED AND IN QUANTITIES AS
RECOMMENDED:
A. BY THE EQUIPMENT MANUFACTURER AND IN ACCORDANCE TO NEC 760.
B. SIGNALING LINE CIRCUIT DEVICE WIRING SHALL BE AWG#16 MINIMUM.
C. ALL WIRING TO BE SOLID COPPER, EXCEPT FOR CIRCUITS REQUIRING SHIELDING.
D. ALARM NOTIFICATION DEVICE WIRING SHALL BE AWG#16 MINIMUM.
E. ALL WIRING TO BE SUPERVISED PER ALL APPLICABLE CODES AND STANDARDS.
F. ALL CONDUIT TO BE METALLIC, 152 MM (3/4") MINIMUM.
G. ALL TERMINATIONS MUST BE AT A TERMINAL STRIP USING SCREW TERMINALS. ALL DEVICES TO HAVE SCREW
TERMINALS.
H. PULL ALL CONDUCTORS SPLICE FREE. MAKE ALL TURNS AT 90 DEGREE ANGLES AND TIGHTLY BUNDLE AND
WRAP ALL WIRE.
I. ALL WIRING TO CONTROL PANELS SHALL BE RUN IN THE VERTICAL OR HORIZONTAL PLANE.
5. ALL STROBE LIGHTS SHALL BE SYNCHRONIZED.
6. ALL DEVICES AND APPLIANCES SHALL BE COMPATIBLE WITH THE CONTROL PANEL. ALL DEVICES AND APPLIANCES
WILL BE MOUNTED AND SPACED PER ALL APPLICABLE CODES AND STANDARDS AS WELL AS MANUFACTURER'S
SPECIFICATIONS.
7. THE ACCEPTANCE TESTING OF THE FIRE ALARM SYSTEM AND COMPONENTS SHALL CONSIST OF ALL APPLICABLE
ITEMS IN NFPA 72, UFC 4-021-01, AND UFC 3-601-02. SEE NFPA 72, CHAPTER 14 FOR DETAILS ON THE APPLICABLE
TESTS. UPON ACCEPTANCE, A COMPLETE SET OF RECORD DRAWINGS SHALL BE SUBMITTED.
8. CONTRACTOR SHALL TAKE EFFECTIVE MEASURES TO REDUCE FALSE ALARMS INCLUDING COORDINATING WITH 17
CE ALARM SHOP AND 17 CEFP OFFICES, MINIMIZE DUST, AS WELL AS COVERING AND PROTECTING FIRE
DETECTION SYSTEMS SUCH AS SMOKE AND HEAT DETECTORS.
9. THE FOLLOWING STAKEHOLDERS SHALL BE INVITED TO ALL FIRE ALARM ACCEPTANCE TESTING: 17 CES FIRE
ALARM TECHNICIANS AND 17 CES FIRE PREVENTION OFFICE.
10. PROVIDE A CAD DRAWN FLOOR PLAN SHOWING LOCATION OF THE DEVICES IN THE ROOMS, AND THEIR
CORRESPONDING ADDRESS. LOCATE A SINGLE FRAMED DRAWING OF THE LOCATIONS OF THE SMOKE
DETECTORS OUTSIDE OF THE SPACE AND ADJACENT TO THE MAIN ENTRANCE PER UFC 3-600-1.
CARBON MONOXIDE DETECTOR
FIRE ALARM GRAPHIC PLAN
FL
D
D D
F L
F L
F L
F L
F L
F L
F L
S
S
S
S
S
S
ELECTRICAL
GENERAL NOTES:
1. REMOVE ALL EXISTING FIRE ALARM DEVICES.
2. CONTRACTOR MAY REUSE EXISTING
CONDUIT AND JUNCTION BOXES
3. ALL NEW DEVICES SHALL BE MOUNTED AT
HEIGHTS REQUIRED BY NFPA 72 AND ABA. IF
NECESSARY THE CONTRACTOR SHALL
RELOCATE JUNCTION BOXES OR BACK
BOXES NOT CURRENTLY AT CORRECT
HEIGHT.
4. ANY JUNCTION BOXES OR BACK BOXES NOT
REUSED SHALL BE PROVIDED WITH A COVER
PLATE. BOXES IN FINISHED AREAS SHALL BE
BRUSHED ALUMINUM. ALL OTHER COVER
PLATES MAY BE EMT OR SIMILAR GAUGE.
FP-002 FP-002
SCALE
F L
FL
D
D
D
D
D
D
D
D
F L
F L
F L
F L
F L
FL
X
X
X
X
X
X
X
X
X
X
ELECTRICAL
GENERAL NOTES:
1. REMOVE ALL EXISTING FIRE ALARM DEVICES.
2. CONTRACTOR MAY REUSE EXISTING
CONDUIT AND JUNCTION BOXES
3. ALL NEW DEVICES SHALL BE MOUNTED AT
HEIGHTS REQUIRED BY NFPA 72 AND ABA. IF
NECESSARY THE CONTRACTOR SHALL
RELOCATE JUNCTION BOXES OR BACK
BOXES NOT CURRENTLY AT CORRECT
HEIGHT.
4. ANY JUNCTION BOXES OR BACK BOXES NOT
REUSED SHALL BE PROVIDED WITH A COVER
PLATE. BOXES IN FINISHED AREAS SHALL BE
BRUSHED ALUMINUM. ALL OTHER COVER
PLATES MAY BE EMT OR SIMILAR GAUGE.
FP-003 FP-003
SCALE
60 CD; C
60 CD; C
60 CD; C60 CD; C
60 CD; C
15 CD; C
60 CD; C
60 CD; C
60 CD; C
C
D
C
C
D
C
C
D
C
C
D
C
60 CD; C
30 CD; C
60 CD; C
15 CD; C
15 CD; C
60 CD; C
C
D
C
C
D
C
15 CD; C
15 CD; C
30 CD; C
60 CD; C
C
D
C
15 CD; C
60 CD; C
60 CD; C
60 CD; C
60 CD; C
60 CD; C
60 CD; C
60 CD; C
60 CD; C
15 CD; C 15 CD; C 15 CD; C 15 CD; C
15 CD; C
15 CD; C15 CD; C
15 CD; C
15 CD; C15 CD; C
15 CD; C
D
D
60 CD; C
60 CD; C
C
D
C
C
D
C
75 CD; C
75 CD; C
C
D
C
C
D
C
X
X
X
X
X
X
X
X
X
X
ELECTRICAL
FP-005 FP-005
SCALE
GENERAL NOTES:
1. MOUNT ALL NEW MANUAL FIRE ALARM
STATIONS SO THAT OPERATING MECHANISM IS
NO MORE THAN 48" AFF.
2. SMOKE DUCT DETECTORS MOUNTED ABOVE 6
FEET AND THOSE MOUNTED BELOW 6 FEET
THAT CANNOT BE EASILY ACCESSED WHILE
STANDING ON THE FLOOR, SHALL BE PROVIDED
WITH A REMOTE DETECTOR INDICATOR PANEL
CONTAINING TEST AND RESET SWITCHES.
3. ALL JUNCTION BOX COVERS AND NEW
RACEWAYS ASSOCIATED WITH THE FIRE ALARM
SYSTEM SHALL BE PAINTED RED. REFER TO
SPECIFICATION 26 20 00 ADDITIONAL
REQUIREMENTS.
1. REPLACE THE EXISTING STANDARD RESPONSE SPRINKLERS
WITH NEW QUICK RESPONSE SPRINKLERS THROUGHOUT
THE ENTIRE ADMINISTRATIVE SPACE, INCLUDING HALLWAYS
AND OFFICES. ENSURE THAT K-FACTOR, TEMPERATURE
RATING, LOCATION, ORIENTATION, AND WATER DISTRIBUTION
CHARACTERISTICS REMAIN THE SAME. INSTALL SPRINKLER
SYSTEM COMPONENTS PER UFC 3-600-01, NFPA 13, AND
MANUFACTURER'S INSTRUCTIONS. THE EXISTING SPRINKLER
SYSTEM (INCLUDING CONTROL VALVES, SYSTEM PIPING,
FITTINGS, HANGARS, PRESSURE GAUGES, ETC.) SHALL
REMAIN.
2. HYDROSTATICALLY TEST THE REPAIRED FIRE SPRINKLER
SYSTEM IN ACCORDANCE WITH NFPA 13 SECTION 25.2. THE
USE OF RECONDITIONED SPRINKLERS IS NOT PERMITTED
PER NFPA 13. THEREFORE, IF SPRINKLERS ARE LEAKING OR
DAMAGED DURING TESTING THEN THEY SHALL BE REPLACED
WITH NEW SPRINKLERS.
FP-006 FP-006
SCALE: 3/32"=1'-0"
X
X
X
X
X
X
X
X
ELECTRICAL
FP-007 FP-007
SCALE: 3/32"=1'-0"
1. REPLACE THE EXISTING STANDARD RESPONSE SPRINKLERS
WITH NEW QUICK RESPONSE SPRINKLERS THROUGHOUT
THE ENTIRE ADMINISTRATIVE SPACE, INCLUDING HALLWAYS
AND OFFICES. ENSURE THAT K-FACTOR, TEMPERATURE
RATING, LOCATION, ORIENTATION, AND WATER DISTRIBUTION
CHARACTERISTICS REMAIN THE SAME. INSTALL SPRINKLER
SYSTEM COMPONENTS PER UFC 3-600-01, NFPA 13, AND
MANUFACTURER'S INSTRUCTIONS. THE EXISTING SPRINKLER
SYSTEM (INCLUDING CONTROL VALVES, SYSTEM PIPING,
FITTINGS, HANGARS, PRESSURE GAUGES, ETC.) SHALL
REMAIN.
2. HYDROSTATICALLY TEST THE REPAIRED FIRE SPRINKLER
SYSTEM IN ACCORDANCE WITH NFPA 13 SECTION 25.2. THE
USE OF RECONDITIONED SPRINKLERS IS NOT PERMITTED
PER NFPA 13. THEREFORE, IF SPRINKLERS ARE LEAKING OR
DAMAGED DURING TESTING THEN THEY SHALL BE REPLACED
WITH NEW SPRINKLERS.
| 8766-1008-CS-001-R000 |
| 8766-1008-CS-002-R000 |
| 8766-1008-CS-003-R000 |
| GOODFELLOW B448 - ARCH 100% |
| 8766-1008-M-000-M-000 |
| 8766-1008-MD-101-24X36 |
| 8766-1008-MD-102&MD103 ENLARGED PLANS - -MD102 |
| 8766-1008-MD-102&MD103 ENLARGED PLANS - -MD103 |
| 8766-1008-MD-201-24X36 |
| 8766-1008-M-101-A |
| 8766-1008-M-101-B |
| 8766-1008-M-101-C |
| 8766-1008-M-101-D |
| 8766-1008-M105&M106 - ENLARGED PLANS-M105 |
| 8766-1008-M105&M106 - ENLARGED PLANS-M106 |
| 8766-1008-M-201-24X36 |
| 8766-1008-M-301 |
| 8766-1008-M-302-M-302 |
| 8766-1008-M-401-M-401 |
| 8766-1008-M-402-M-402 |
| 8766-1008-M-501-24X36 |
| 8766-1008-M-502-24X36 |
| 8766-1008-M-503-24X36 |
| 8766-1008-M-504-24X36 |
| 8766-1008-M-505-24X36 |
| 8766-1008-M-601-24X36 |
| 8766-1008-M-602-24X36 |
| 8766-1008-M-701-M-701 |
| 8766-1008-M-701-M-702 |
| E-000-E-000 |
| ED-101-ED-101 |
| ED-201-ED-201 |
| ED-202-ED-202 |
| ED-203-ED-203 |
| ED-301-ED-301 |
| ED-302-ED-302 |
| ED-303-ED-303 |
| ED-304-ED-304 |
| E-101-E-101 |
| E-201-E-201 |
| E-202-E-202 |
| E-203-E-203 |
| E-301-E-301 |
| E-302-E-302 |
| E-303-E-303 |
| E-304-E-304 |
| E-501-E-501 |
| E-601-E-601 |
| E-602-E-602 |
| E-603-E-603 |
| EG-101-EG-101 |
| FP-001 |
| FP-002 |
| FP-003 |
| FP-004 |
| FP-005 |
| FP-006 |
| FP-007 |