502 CONS/JBKAE FA301619U0122
JBSA-Lackland CCTV and Intercom Voice System
Equipment Specifications Page 1 of 4 Attachment 2
Product Specifications
Closed Circuit TV Cameras must provide the following minimum specifications:
Cameras must provide a minimum resolution of 640-480 pixels.
Cameras must provide a color image with a horizontal resolution of at least 470 lines, when operating in daytime mode.
Cameras must be adjustable to produce 1.0-volt peak to peak video.
Cameras must provide 0.4 volt negative sync with no blooming, streaking, or lag.
Cameras must have 1/2-inch wide-dynamic-range CCD (Charge Coupling Device) imager.
40 Channel HD or SDI PC-Based Hardware RAID 5 Network Video Server w/4TB Hot
Swappable Enterprise Storage.
Camera & Lens system must provide a minimum light level sensitivity such that can render a scene 75% of lit; with an average ambient light level of .1 lux; with an average NTSC (National Television System Committee) level of 30IRE (Institute of
Radio Engineer); without the use of more than 18dB of electronic gain; while maintaining a minimum frame rate of 5 frame per second, when the lens is at widest aperture.
Cameras installed in exterior locations must have an Environmental Sealable
Housing; cameras must have the ability to switch from Day and Night mode automatically, with Infra-Red (/R) auto illuminators.
Digital Video Recorder (DVR) must provide the following minimum specifications:
DVR system must have the operational ability to transcode video to at least one of the following formats: mpeg2, mpeg4, H263, or H264. This operational ability shall be natively designed into the DVR system, and shall not require the use of additional software or equipment. Additionally, the contractor shall implement, install, and support an upgraded intercom system with ability to provide 2 way communication between CQ station and each of 20 dormitories, as well as provide public announcement capabilities to all speakers both internal and external to the building.
DVR must be installed within an operations room for easy access.
DVR system must have the ability to record at a minimum of 5 frames per second, with a resolution of 640x480 pixels.
Equipment Specifications Page 2 of 4 Attachment 2
DVR system must have a dual power supply, consisting of AC 110v electrical current, and be connected to an Emergency Battery UPS (Uninterrupted Power
Supply).
DVR system must have high–density real time recording on all channels simultaneously, with the ability to record with applicable internal disk drive space.
Internal CD/DVD writer and front and back USB (Universal Serial bus) ports.
Simultaneous Live/Record/Playback/Network with independent recording profiles.
Advanced VMD (Video Motion Detector) Area, vector and duration.
Equipment (or next generation equipment must be upgradable to meet future expansion requirements, and allow interconnection via industry Internet Protocol - IP network infrastructure for central control.
Equipment shall conform to the requirements of the FCC and EIA rules and regulations covering television equipment. All work in conjunction with this installation shall meet the provisions of the NFPA 70 National Electric Code (NEC) and any other applicable codes.
The surveillance cameras shall be installed in such a way that there are no blind spots or areas without coverage on the exterior of the building. The CCTV system shall provide for the monitoring of the interior and exterior of all three facilities. Sufficient monitors and digital video recorders along with required power supply shall be located in a lockable security cabinet in the facility.
The CCTV system must use assignable levels of access for system privileges to include system access i.e., password/password reset.
The CCTV system must be user programmable by personnel with management or executive privileges.
The CCTV system must provide a facility and system access history log for a minimum of 30 days and maximum of 60 days to record system alterations, attempted and granted access, and system malfunctions.
System components must consist of a user interface PC, keyboard, mouse, and operate on MS® Windows operating system.
System Software must allow real-time monitoring, searchable data, and user configurable graphing of all logged parameters.
DVR System must track and log all events to include the event description, time, date, and who executed the command (user); accessible only by designated administrators.
The contractor shall connect all equipment to the monitors located at the CQ.
Equipment Specifications Page 3 of 4
SECURITY CABINET shall be a cabinet with keyed lockable door. Cabinet shall be made from heavy-gauge steel with front rack rails, louvered sides, hinges and black baked enamel finish. Provide cooling fan mounted on louvered side with built in cord and plug.
ADDITIONAL SPECIFICATIONS – TO INCLUDE
ITEM QUANTITY
DVR 2
Demo Camera 46
Exterior 180 Degree Camera 1
Wall Mount for Exterior Camera 1
Exterior Dome Camera 25
Wall Mount for Exterior Camera 20
Junction Box for Exterior Camera 20
Surface Mount for Exterior Camera 4
Surge Suppression (Rack) 2
Surge Suppression (Device) 27
Interior Camera 29
Wall Mount for Interior Camera 8
Surface Mount for Interior Camera 21
Camera Power Supply 5
Siamese Cable 4
BNC Connectors 11
Labels 3
Jhooks 150
Vecro 2
Equipment Specifications Page 4 of 4
FireStop 4
Penetration 2
Weather Sealant 2
Monitor 2
Monitor Mount 2
VGA Cable 2
2 conductor cable 2
Intercom system must provide the following minimum specifications:
System must be able to provide clear two way communication between the Charge of Quarters
(CQ) desk and each of the 20 dormitories.
The Entry Controller (EC) station at the front of each dormitory must be able to initiate communication back to the CQ desk.
Additional speakers will be installed further in the dormitory bay in each of the 20 dorms to broadcast any public announcements.
Intercom system will be able to broadcast in multiple modes. Two way communication between CQ and EC station, and public broadcast mode which will provide a one way announcement feature from CQ station to all speakers, interior and exterior.
Intercom system will be able to play a pre-recorded message that can be broadcast in
PA mode.