SPECIFICATIONS
FOR
Installation of Shade Structure and Aluminum Bleachers at Training Area Eight on Lackland AFB.
(Addendum 2 16 August 2019)
PREPARED BY
Chris Banks 37 TRSS/JBSA-Lackland
(210) 671-3710
STATEMENT OF WORK
JBSA-Lackland Training Annex
502d CONS/JBKAE
JBSA LACKLAND, TX 78236
F2MTRD9123AW01 / F2MTR39022AW01
GUN RANGE - TRAINING AREA EIGHT SHADE STRUCTURES
1. DESCRIPTION OF WORK
Work to be done: The work to be performed under this contract and in accordance with these contract documents shall consist of furnishing all necessary plant, labor, materials; and installing and performing all work shown and described in the contract documents, all of which are made a part thereof.
2. PRINCIPAL FEATURES
SCOPE OF WORK: The contractor shall provide all personnel, equipment, tools, materials, supplies, labor, supervision, and other necessities to install shade structure w/ aluminum bleachers. The new structure will support and meet the standards for operation for use of TA-8 (see attachment 1).
• Be responsible for conducting a site survey prior to proposal submittal to determine conditions which may affect final quoted price.
• A dig permit is needed for this project and it will be incumbent upon the contractor to get the appropriate approvals.
• Post signs warning of installation area. Signs must be in plain view for pedestrian/vehicle traffic to see.
SHADE STRUCTURE REQUIREMENTS:
• The contractor shall erect a 36’L x 36’W – Four pole Hip/Pyramid, 11’ at the lowest point of the canopy from the ground. The canopy will be beige or desert tan in color.
The canopy shall be constructed with coated polyester UV and flame resistant, WATERPROOF fabric. Fabric will be sewn with UV resistant thread. The structure and fabric shall be engineered to withstand 90 mile per hour winds. The concrete support columns must be installed on grade w/ the existing asphalt surface (six feet deep). in the ground six feet deep.
• Ensure all steel is finished in desert tan or beige paint with a 2.5 to 3.5 mil. Thick UV inhibited weather resistant powder coat. Shade canopy corners shall be reinforced at secure points with steel support structure. The canopy shall be reinforced throughout to ensure strength in welded connections/joints. All cabling shall be corrosion resistant and provide sufficient strength to provide increased tension and security between the canopy and support structure. All hardware used in this project shall be galvanized and/or be rust/corrosion resistant.
• Shade cover fabric must be wrought tight enough to prevent water from pooling atop the shade cover at any point.
ALUMINUM BLEACHER REQUIREMENTS:
Formatted: Strikethrough
Commented [BCNGUA3T1]: No asphalt surface.
502d CONS/JBKAE
JBSA LACKLAND, TX 78236
F2MTRD9123AW01 / F2MTR39022AW01
• The contractor shall install a 10 Row x 24’L, Non-Elevated, All-Aluminum Bleacher
• 5/16” x 11/4” carriage bolt and serrated nut
• 3 ½” aluminum bolt clip
• Single 2” x 10” anodized aluminum seat planks
• Double 2” x 10” mill finish aluminum tread planks per row
• Chain link and 3 rail schedule 40 anodized aluminum pipe guardrail system
The contractor shall visit the proposed site with Chris Banks, 37 TRSS, (210) 671- 3768 or Detra Whitfield (210) 671-6177.
SPECIFIC TASKS:
Character of Work and Mechanics: The work shall be in strict accordance with the contract documents and standards of the industry. Only certified journeymen in respective trades, or apprentices under the direct supervision of certified journeymen will be permitted to work within the electrical or sheet metal areas of projects. A current state or municipal tested electrical license will be recognized as certification upon approval by the Contracting Officer. License shall be available for Government inspection as directed by the Contracting Officer and from mechanics and electricians at the jobsite throughout contract operations. For those trades not requiring a license, the contractor shall ensure qualified and experienced personnel in their trades are assigned to government project work. The government reserves the right to request work references.
Work shall be done with the buildings occupied and the work areas unoccupied. The contractor shall coordinate all work with the occupants, the Project Manager/Inspector, the Contracting Officer Representative and/or Contracting Officer. The contractor shall perform all work in accordance with industrial, environmental, and OSHA standards. Work must be performed in a manner that limits as much as possible any disruptions to the normal day-to-day operations of Air Force personnel at the site.
The contractors shall examine the site and determine for themselves the existing conditions and general character of the site. Claims for additional costs due to conditions that could have been verified by site investigation will not be permitted.
The contractor shall have all equipment and materials required to perform the specified work on site prior to beginning any work. The work shall be accomplished in the shortest time period possible, during standard business hours, and with a minimum of inconvenience to the users of building.
The contractor shall not work or store materials in a manner that would hinder or otherwise block pedestrian circulation to exit corridors and exit doors in the event of an emergency or fire. Storage of materials shall be coordinated with the Contracting Officer.
3. WORK HOURS AND SPECIAL CONDITIONS
Work hours shall be 7:30 a.m. to 4:30 p.m., Monday through Friday, exclusive of Federal holidays.
At the option of the government and with approval of the Contracting Officer, work may be
502d CONS/JBKAE
JBSA LACKLAND, TX 78236
F2MTRD9123AW01 / F2MTR39022AW01
permitted on Federal holidays, weekends or after 4:30 p.m. daily at no additional cost to the government. The following legal holidays are observed:
New Year’s Day, January 1st Dr. Martin Luther King, Jr. Day, 3rd Monday in January Washington’s Day, 3rd Monday in February Memorial Day, Last Monday in May Independence Day, July 4th Labor Day, 1st Monday in September Columbus Day, 2nd Monday in October Veterans Day, November 11th Thanksgiving Day, 4th Thursday in November Christmas Day, December 25th
Note: When any of the above holidays falls on a Saturday, the preceding Friday will be observed as the legal holiday; holidays falling on a Sunday will be observed on the following Monday.
4. BASE FIRE REGULATIONS
The contractor shall comply with all JBSA-Lackland Fire Regulations. No welding will be permitted without obtaining a welding permit issued by the JBSA-Lackland Fire Department.
All fire and safety regulations shall be enforced.
5. SITE MAINTENANCE AND CLEANUP
Site Maintenance: The contractor shall maintain work areas in a neat, clean, and safe condition.
Cleanup: The contractor shall collect all trash, debris, refuse, garbage, etc., which is generated and place it in appropriate containers with lids or approved covers daily. The aforementioned materials shall be removed from the site by appropriate means daily, unless otherwise approved by the Contracting Officer. Disposal shall be outside the limits of government property.
All Contractor/Subcontractor employees working under this contract shall comply with the Installation Traffic Regulations.
6. RECORDS MANAGEMENT
The Contractor shall manage all data created for Government use or legally controlled by the Government, in support of the functional activity or required by AF publication, IAW with the AF Records Management procedures in Air Force Instruction (AFI) 33-322, Air Force Manual (AFMAN) 33-363 and Air Force Instruction (AFI) 33-364 (or their subsequent replacements).
7. INSPECTIONS AND ACCEPTANCE
Inspection and acceptance will be at the project site by the Contracting Officer and/or Chris Banks, 37 TRSS, (210) 671-3710 and Detra Whitfield (210) 671-6177
502d CONS/JBKAE
JBSA LACKLAND, TX 78236
F2MTRD9123AW01 / F2MTR39022AW01
Attachment 1
502d CONS/JBKAE
JBSA LACKLAND, TX 78236
F2MTRD9123AW01 / F2MTR39022AW01