MAHG19-1042

29 JULY 2019

Section 09 90 00_1/7

SECTION 09 90 00 – PAINTING AND COATING

PART 1 – GENERAL

1.1 SUMMARY

A. Extent of painting work is shown on drawings and schedules, and as herein specified.

1. Interior and exterior painting, including surface preparation.

2. Painting of existing surfaces is to be performed only where indicated on Drawings.

B. "Paint" as used herein means all coating systems materials, including primers, emulsions, enamels, stains, varnishes, sealers and fillers, and other applied materials whether used as prime, intermediate or finish coats.

C. Following categories of work are not included as part of field-applied finish work, or are included in other sections of these specifications.

1. Shop Priming:

a. Unless otherwise specified, shop priming of ferrous metal items is included under various sections for structural steel, steel joists, metal fabrications, hollow metal work, and similar items. Also, for factory built mechanical and electrical equipment or accessories.

2. Pre-finished Items:

a. Unless otherwise indicated, do not include painting when factory-finishing or installer finishing is specified for such items as (but not limited to) windows, plastic laminate, acoustical materials and finished mechanical and electrical equipment, including light fixtures.

3. Concealed Surfaces:

a. Unless otherwise indicated, painting is not required on surfaces such as walls or ceilings in concealed areas and generally inaccessible areas, furred areas, pipe spaces, and duct shafts.

b. Backprime finished woodwork and cabinets. Use primer specified for exposed surfaces.

4. Finished Metal Surfaces:

a. Metal surfaces of anodized aluminum, stainless steel, chromium plate, bronze and similar finished materials will not require finish painting, unless otherwise indicated.

5. Operating Parts and Labels:

a. Moving parts of operating units, mechanical and electrical parts, such as valve and damper operators, linkages, sinkages, sensing devices, motor and fan shafts will not require finish painting, unless otherwise indicated. Do not paint over any code-required labels, such as Underwriters' Laboratories and Factory Mutual, or any equipment identification, performance rating, name or nomenclature plates.

Section 09 90 00_2/7

6. Do not paint concrete or floors, unless specifically indicated.

7. Gypsum wallboard joint preparation is included in Gypsum Wallboard Section.

1.2 SUBMITTALS

A. Product Data:

1. Provide manufacturer's printed product data on all coatings specified, including preparation and application instructions.

B. Selection Samples:

1. Provide two sets of samples not less than one by two inches in size illustrating range of colors and textures available for each finishing product specified.

C. Verification Samples:

1. Provide two samples of not less than six inches square illustrating selected color and texture for each finishing product specified.

1.3 QUALITY ASSURANCE

A. Job Sample:

1. Prior to start of painting, paint full size field sample of each individual color scheduled on each respective substrate. Paint sample at site, where directed, of workmanship to be expected in the completed work. Obtain Contracting Officer’s acceptance of the sample before start of work. If sample is accepted, the sample may become part of the finished project.

1.4 DELIVERY, STORAGE, AND HANDLING

A. Deliver materials to job site in original, new and unopened packages and containers bearing manufacturer's name and label and following minimum information:

1. Name or title of materials

2. Manufacturer's name

3. Thinning instructions

4. Application instructions

5. Color name and number

B. Store paint products in covered, ventilated area at minimum ambient temperature of 45 degrees F and maximum ambient temperature of 90 degrees F.

1.5 PROJECT CONDITIONS

A. Apply water-base paints only when temperature of surfaces to be painted and surrounding air temperatures are between 50 degrees F. (10 Celsius) and 90 degrees F. (32 Celsius), unless otherwise permitted by paint manufacturer's printed instructions.

B. Apply solvent-thinned paints only when temperature of surfaces to be painted and surrounding air temperatures are between 45 degrees F. (7 Celsius) and 95 degrees F. (35

Section 09 90 00_3/7

Celsius), unless otherwise permitted by paint manufacturer's printed instructions.

C. Do not apply paint in snow, rain, fog or mist; or when relative humidity exceeds 85%; or to damp or wet surfaces, unless otherwise permitted by paint manufacturer's printed instructions.

D. Painting may be continued during inclement weather if areas and surfaces to be painted are enclosed and heated within temperature limits specified by paint manufacturer during application and drying periods.

1.6 EXTRA MATERIALS

1. At project closeout, supply the Owner or owner's representative one gallon of each product for touch-up purposes. Cans shall be clearly marked with color name, number and type of paint.

2. At project closeout, provide the color mixture name and code to the Owner or owner's representative for accurate future color matching.

1.7 WARRANTY

3. Inspection of all surfaces to be coated must be done by the manufacturer's representative to insure proper preparation prior to application. All thinners, fillers, primers and finish coatings shall be from the same manufacturer to support a product warranty. Products other than those submitted shall be accompanied by a letter stating its fitness for use and compatibility.

4. At project closeout, provide to the Owner or owner's representative an executed copy of the Manufacturer's standard form outlining the terms and conditions of and any exclusions to their Limited Warranty against Manufacturing Defect.

PART 2 – PRODUCTS

2.1 MANUFACTURERS

A. Acceptable Manufacturers:

1. Benjamin Moore

2. Sherwin-Williams Company

3. Glidden Professional

4. “Or, approved equal”

B. Unless otherwise specified for an individual product or material, supply all products specified in this section from the same manufacturer.

2.2 PAINT, GENERAL

A. Material Compatibility:

1. Provide materials for use within each paint system that are compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.

Section 09 90 00_4/7

2. For each coat in a paint system, provide products recommended in writing by manufacturers of topcoat for use in paint system and on substrate indicated.

B. VOC Content of Field-Applied Interior Paints and Coatings: Provide products that comply with the following limits for VOC content, exclusive of colorants added to a tint base, when calculated according to 40 CFR 59, Subpart D (EPA Method 24); these requirements do not apply to paints and coatings that are applied in a fabrication or finishing shop:

1. Flat Paints, Coatings, and Primers: VOC content of not more than 50 g/L.

2. Nonflat Paints, Coatings, and Primers: VOC content of not more than 150 g/L.

3. Anti-Corrosive and Anti-Rust Paints Applied to Ferrous Metals: VOC not more than

250 g/L.

4. Shellacs, Clear: VOC not more than 730 g/L.

5. Shellacs, Pigmented: VOC not more than 550 g/L.

6. Primers, Sealers, and Undercoaters: VOC content of not more than 200 g/L.

2.3 MIXING AND TINTING

A. Except where specifically noted in this section, all paint shall be ready-mixed and pre-tinted.

Agitate all paint prior to and during application to ensure uniform color, gloss, and consistency.

B. Thinner addition shall not exceed manufacturer's printed recommendations. Do not use kerosene or other organic solvents to thin water-based paints.

2.4 INTERIOR PAINT SYSTEMS

A. Latex Flat, Egg-Shell, Semi-Gloss, and Primer:

1. Interior latex containing zero-VOC’s. Provide one of the following:

a. Sherwin-Williams Company: Harmony Coating System

b. Benjamin Moore: Pristine Eco-Spec

c. Glidden Professional: LifeMaster

2. Custom colorants shall be low-VOC and not increase emissions.

B. Concrete floor sealer:

1. Interior or exterior clear floor sealer for existing floors:

a. Sherwin-Williams Company: H&C Concrete Sealer

b. Benjamin Moore: Super Spec 100% Acrylic Masonry Sealer

C. Other products (alkyd, shellacs, etc) shall be submitted prior to use for approval by Contracting Officer in accordance with VOC content as specified herein.

Section 09 90 00_5/7

2.4 EXTERIOR PAINT SYSTEMS

A. CONCRETE (Cementitious Siding, Flexboard, Transite Board, Shingles (Non-Roof), Common Brick, Stucco, Tilt-up, Precast, and Poured-in-place Cement).

1.1 Latex Systems:

A. Gloss Finish:

1. 1st Coat: Benjamin Moore Super Spec® Interior/Exterior Acrylic High

Build Masonry Primer N068 (97g/L), MPI # 3, LEED 2009.

2. 2nd Coat: Benjamin Moore Ben Waterborne Exterior Soft-Gloss 543 (45 g/L), MPI # 11.

3. 3rd Coat: Benjamin Moore Ben Waterborne Exterior Soft-Gloss 543 (45 g/L), MPI # 11.

B. Semi-Gloss Finish:

1. 1st Coat: Benjamin Moore Super Spec® Interior/Exterior Acrylic High Build Masonry Primer N068 (97g/L), MPI # 3, LEED 2009.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss N403 (43 g/L), MPI # 11, 311.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss N403 (43 g/L), MPI # 11, 311.

C. Satin Finish:

1. 1st Coat: Benjamin Moore Super Spec® Interior/Exterior Acrylic High

Build Masonry Primer N068 (97g/L), MPI # 3, LEED 2009.

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI #

15.

3. 3rd Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI #

15.

D. Satin Finish:

1. 1st Coat: Benjamin Moore Super Spec® Interior/Exterior Acrylic High Build Masonry Primer N068 (97g/L), MPI # 3, LEED 2009.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

E. Flat Finish:

1. 1st Coat: Benjamin Moore Super Spec® Interior/Exterior Acrylic High

Build Masonry Primer N068 (97g/L), MPI # 3, LEED 2009.

2. 2nd Coat: Benjamin Moore ben Waterborne Exterior Flat 541 (44 g/L), MPI # 10.

3. 3rd Coat: Benjamin Moore ben Waterborne Exterior Flat 541 (44 g/L), MPI # 10.

F. Flat Finish:

1. 1st Coat: Benjamin Moore Super Spec® Interior/Exterior Acrylic High Build Masonry Primer N068 (97g/L), MPI # 3, LEED 2009.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

G. High Build Coating:

1. 1st Coat: Coronado Texcrete WB Acrylic Masonry Waterproofer Smooth

Finish 3194 (90 g/L), LEED Credit.

1.2 Elastomeric System: Not including cementitious siding, Flexboard, Transite board or shingles (non-roof).

A. Flat Finish:

1. 1st Coat: Benjamin Moore Super Spec® Interior/Exterior Acrylic High Build Masonry Primer N068 (97g/L), MPI # 3, LEED 2009.

2. 2nd Coat: Benjamin Moore Super Spec® Masonry 100% Acrylic Elastomeric Coating Flat 056 (99 g/L).

Section 09 90 00_6/7

3. 3rd Coat: Benjamin Moore Super Spec® Masonry 100% Acrylic Elastomeric Coating Flat 056 (99 g/L).

1.3 Textured and Smooth Systems:

A. Textured (Water Based Finish):

1. 1st Coat: Coronado Texcrete WB Acrylic Masonry Waterproofer Smooth 3194 (90 g/L), LEED Credit.

2. 2nd Coat:

a. Finish Texture- Fine: Coronado Texcrete WB Acrylic Masonry

Waterproofer Sand Finish 3192 (78 g/L), LEED Credit.

b. Finish Texture- Smooth: Coronado Texcrete WB Acrylic Masonry

Waterproofer Smooth Finish 3194 Line (90 g/L), LEED Credit.

c. Finish Texture- Medium: Coronado Texcrete WB Acrylic Masonry

Waterproofer Medium Finish 3196 Line (20 g/L), MPI # 42, LEED Credit.

B. Smooth (Water Based Finish):

1. 1st Coat: Coronado Texcrete WB Acrylic Masonry Waterproofer Smooth

Finish 3194 (90 g/L), LEED Credit.

2. 2nd Coat: Coronado Texcrete WB Acrylic Masonry Waterproofer Smooth

Finish 3194 (90 g/L), LEED Credit.

1.4 Stain System:

A. Solid Color Waterborne Finish:

1. 1st Coat: Coronado TuffCrete Waterborne Acrylic Concrete Stain CST-

2000 (153 g/L), MPI # 58.

2. 2nd Coat: Coronado TuffCrete Waterborne Acrylic Concrete Stain CST-

2000 (153 g/L), MPI # 58.

B. MASONRY: Concrete Masonry Units (CMU) - Cinder or Concrete Block.

1.5 Latex Systems:

A. Gloss Finish:

1. 1st Coat: Coronado Super Kote 5000 Production Block Filler 958-11 (35 g/L), MPI # 4, X-Green 4, LEED V4, CHPS Certified.

2. 2nd Coat: Coronado Cryli Cote 100% Acrylic Gloss House & Trim Paint 2

(94 g/L).

3. 3rd Coat: Coronado Cryli Cote 100% Acrylic Gloss House & Trim Paint 2

(94 g/L).

B. Gloss Finish - Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Super Spec® Masonry Interior/Exterior Hi- Build Block Filler 206 (45 g/L), MPI # 4, X-Green 4, LEED 2009, LEED V4, CHPS Certified.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss N403 (43 g/L), MPI # 11, 311.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss N403 (43 g/L), MPI # 11, 311.

C. Semi-Gloss Finish:

1. 1st Coat: Coronado Super Kote 5000 Production Block Filler 958-11 (35 g/L), MPI # 4, X-Green 4, LEED V4, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec HP D.T.M. Acrylic Semi-Gloss

Enamel, HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009, LEED V4.

3. 3rd Coat: Benjamin Moore Ultra Spec HP D.T.M. Acrylic Semi-Gloss Enamel, HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009, LEED V4.

D. Satin Finish:

1. 1st Coat: Coronado Super Kote 5000 Production Block Filler 958-11 (35 g/L), MPI # 4, X-Green 4, LEED V4, CHPS Certified.

2. 2nd Coat: Coronado Cryli Cote 100% Acrylic Satin House & Trim Paint

410 (83 g/L).

3. 3rd Coat: Coronado Cryli Cote 100% Acrylic Satin House & Trim Paint

Section 09 90 00_7/7

410 (83 g/L).

E. Satin Finish - Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Super Spec® Masonry Interior/Exterior Hi- Build Block Filler 206 (45 g/L), MPI # 4, X-Green 4, LEED 2009, LEED V4, CHPS Certified.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

F. Flat Finish:

1. 1st Coat: Coronado Super Kote 5000 Production Block Filler 958-11 (35 g/L), MPI # 4, X-Green 4, LEED V4, CHPS Certified.

2. 2nd Coat: Coronado Cryli Cote 100% Acrylic Flat House & Trim Paint 10

(44 g/L), MPI # 10.

3. 3rd Coat: Coronado Cryli Cote 100% Acrylic Flat House & Trim Paint 10

(44 g/L), MPI # 10.

G. Flat-Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Super Spec® Masonry Interior/Exterior Hi- Build Block Filler 206 (45 g/L), MPI # 4, X-Green 4, LEED 2009, LEED V4, CHPS Certified.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

H. High Build Coating

1. 1st Coat: Coronado Texcrete WB Acrylic Masonry Waterproofer Smooth

Finish 3194 (90 g/L), LEED Credit.

1.6 Elastomeric System:

A. Flat Finish

1. 1st Coat: Benjamin Moore Super Spec® Masonry Interior/Exterior Hi-

Build Block Filler 206 (45 g/L), MPI # 4, X-Green 4, LEED 2009, LEED V4, CHPS Certified.

2. 2nd Coat: Benjamin Moore Super Spec® Masonry 100% Acrylic Elastomeric Coating Flat 056 (99 g/L).

3. 3rd Coat: Benjamin Moore Super Spec® Masonry 100% Acrylic Elastomeric Coating Flat 056 (99 g/L).

1.7 Textured Masonry System:

A. Textured (Water Based Finish)

1. 1st Coat: Coronado Texcrete WB Acrylic Masonry Waterproofer Smooth Finish 3194 (90 g/L), LEED Credit.

2. 2nd Coat: Coronado Texcrete WB Textured Waterproofer

a. Finish Texture Sand: 3192 (78 g/L), LEED Credit.

b. Finish Texture Medium: 3196 (20 g/L) MPI # 42, LEED Credit.

B. Smooth (Water Based)

1. 1st Coat: Coronado Texcrete WB Acrylic Masonry Waterproofer Smooth

Finish 3194 (90 g/L), LEED Credit.

2. 2nd Coat: Coronado Texcrete WB Acrylic Masonry Waterproofer Smooth

Finish 3194 (90 g/L), LEED Credit.

1.8 Stain System:

A. Solid Color Waterborne Stain Finish:

1. 1st Coat: Insl-X TuffCrete Solvent Acrylic Concrete Stain &

Waterproofing Sealer CST-5100 (651 g/L), MPI # 58, 104.

2. 2nd Coat: Insl-X TuffCrete Solvent Acrylic Concrete Stain &

Waterproofing Sealer CST-5100 (651 g/L), MPI # 58, 104.

1.9 Clear Water Repellant:

A. Clear Finish

1. 1st Coat: Coronado Texcrete Silicone Water Repellant 194 (21 g/L), MPI

# 117, LEED Credit.

Section 09 90 00_8/7

2. 2nd Coat: Coronado Texcrete Silicone Water Repellant 194 (21 g/L), MPI # 117, LEED Credit.

C. CONCRETE: Concrete Floors (non-vehicular), Patios, Porches, Steps and Platforms.

1.10 Acrylic System Water-Based:

A. Floor Finish:

1. 1st Coat: Benjamin Moore Floor & Patio Latex Enamel Low Sheen N122

(45 g/L), LEED 2009.

2. 2nd Coat: Benjamin Moore Floor & Patio Latex Enamel Low Sheen N122

(45 g/L), LEED 2009.

D. METAL: Aluminum, Galvanized.

1.11 Latex Systems:

A. Gloss Finish:

1. 1st Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L)

MPI # 11.

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L)

MPI # 11.

B. Gloss Finish- Early Moisture Resistant Finish

1. 1st Coat: Benjamin Moore Ultra Spec D.T.M. Acrylic Gloss Enamel HP28 (142 g/L), MPI # 114, X-Green 114, 154, X-Green 154, 164, LEED 2009, LEED V4.

2. 2nd Coat: Benjamin Moore Ultra Spec D.T.M. Acrylic Gloss Enamel HP28 (142 g/L), MPI # 114, X-Green 114, 154, X-Green 154, 164, LEED

2009, LEED V4.

C. Semi-Gloss Finish:

1. 1st Coat: Benjamin Moore Ultra Spec HP Acrylic DTM Semi-Gloss

Enamel HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009.

2. 2nd Coat: Benjamin Moore Ultra Spec HP Acrylic DTM Semi-Gloss Enamel HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009.

D. Satin Finish:

1. 1st Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI # 15.

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI #

15.

E. Satin Finish- Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

F. Flat Finish:

1. 1st Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

2. 2nd Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

G. Flat Finish- Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

E. METAL: Misc. Iron, Ornamental Iron, Structural Iron and Steel, Ferrous Metal.

1.12 Latex Systems:

A. Gloss Finish

1. 1st Coat: Corotech Acrylic Metal Primer V110 (199 g/L), LEED Credit.

Section 09 90 00_9/7

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L)

MPI # 11.

3. 3rd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L)

MPI # 11.

B. Semi-Gloss Finish

1. 1st Coat: Corotech Acrylic Metal Primer V110 (199 g/L), LEED Credit.

2. 2nd Coat: Benjamin Moore Ultra Spec HP D.T.M. Acrylic Semi-Gloss

Enamel, HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009, LEED V4.

3. 3rd Coat: Benjamin Moore Ultra Spec HP D.T.M. Acrylic Semi-Gloss Enamel, HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009, LEED V4.

F. WOOD: Decks, Exterior including pressure treated lumber, Floors (non- Vehicular), Platforms.

1.13 Acrylic Water-Based Floor System:

A. Floor Finish:

1. 1st Coat: Benjamin Moore Fresh Start Multi-Purpose Primer N023 (44 g/L), MPI # 6, 17, X-Green 17, 39, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Floor & Patio Latex Enamel Low Sheen N122 (45 g/L), LEED 2009.

1.14 Stain Systems:

A. Solid Color Acrylic Latex:

1. 1st Coat: Benjamin Moore Arborcoat Solid Deck & Siding Stain 640 (93 g/L), MPI # 16.

2. 2nd Coat: Benjamin Moore Arborcoat Solid Deck & Siding Stain 640 (93 g/L), MPI # 16.

B. Semi-Transparent Stain:

1. 1st Coat: Benjamin Moore Arborcoat Semi-Transparent Deck & Siding

Stain N638 (92 g/L), MPI # 156.

2. 2nd Coat: Benjamin Moore Arborcoat Semi-Transparent Deck & Siding

Stain N638 (92 g/L), MPI # 156.

C. Clear Stain:

1. 1st Coat: Benjamin Moore Arborcoat Waterproofer 320 (34 g/L).

G. WOOD: Siding, Trim, Shutters, Sashes, Hardboard-Bare/Primed.

1.15 Latex Systems:

A. Gloss Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L), MPI # 11.

3. 3rd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L), MPI # 11.

B. Gloss Finish - Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss N403 (43 g/L), MPI # 11, 311.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss N403 (43 g/L), MPI # 11, 311.

Section 09 90 00_10/7

C. Semi-Gloss Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec HP D.T.M. Acrylic Semi-Gloss Enamel, HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009, LEED V4.

3. 3rd Coat: Benjamin Moore Ultra Spec HP D.T.M. Acrylic Semi-Gloss Enamel, HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009, LEED V4.

D. Satin Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI # 15.

3. 3rd Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI # 15.

E. Satin Finish - Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

F. Flat Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

3. 3rd Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

G. Flat Finish - Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

1.16 Stain - Water Reducible Systems:

A. Semi-Transparent:

1. 1st Coat: Benjamin Moore Arborcoat Semi-Transparent Deck & Siding Stain N638 (92 g/L) MPI # 156.

2. 2nd Coat: Benjamin Moore Arborcoat Semi-Transparent Deck & Siding Stain N638 (92 g/L) MPI # 156.

B. Solid Color:

1. 1st Coat: Benjamin Moore Arborcoat Solid Deck & Siding Stain 640 (93 g/L) MPI # 16.

2. 2nd Coat: Benjamin Moore Arborcoat Solid Deck & Siding Stain 640 (93 g/L) MPI # 16.

H. ARCHITECTURAL PVC, PLASTIC, FIBERGLASS

1.17 Latex Systems:

Section 09 90 00_11/7

1. 1st Coat: Insl-X Stix Waterborne Bonding Primer SXA-110 (47 g/L).

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L)

MPI # 11.

3. 3rd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L)

MPI # 11.

B. Semi-Gloss:

1. 1st Coat: Insl-X Stix Waterborne Bonding Primer SXA-110 (47 g/L).

2. 2nd Coat: Benjamin Moore Ben Waterborne Exterior Soft-Gloss 543 (45 g/L), MPI # 11.

3. 3rd Coat: Benjamin Moore Ben Waterborne Exterior Soft-Gloss 543 (45 g/L), MPI # 11.

C. Satin Finish:

1. 1st Coat: Insl-X Stix Waterborne Bonding Primer SXA-110 (47 g/L).

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI #

15.

3. 3rd Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI #

15.

D. Flat Finish:

1. 1st Coat: Insl-X Stix Waterborne Bonding Primer SXA-110 (47 g/L).

2. 2nd Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

3. 3rd Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

I. DRYWALL: Gypsum Board, Exterior Drywall.

1.18 Latex Systems:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ben Waterborne Exterior Soft-Gloss 543 (45 g/L), MPI # 11.

3. 3rd Coat: Benjamin Moore Ben Waterborne Exterior Soft-Gloss 543 (45 g/L), MPI # 11.

B. Gloss Finish - Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss N403 (43 g/L), MPI # 11, 311.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss N403 (43 g/L), MPI # 11, 311.

C. Semi-Gloss Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec HP D.T.M. Acrylic Semi-Gloss Enamel, HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009, LEED V4.

3. 3rd Coat: Benjamin Moore Ultra Spec HP D.T.M. Acrylic Semi-Gloss Enamel, HP29 (147 g/L), MPI # 141, X-Green 141, 153, X-Green 153, LEED 2009, LEED V4.

D. Satin Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green

Section 09 90 00_12/7

137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore ben Exterior Low Luster 542 (45 g/l), MPI #

15.

3. 3rd Coat: Benjamin Moore ben Exterior Low Luster (45 g/l), MPI # 15.

E. Satin Finish - Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Low Lustre N401 (40 g/L), MPI # 15, 315.

F. Flat Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore ben Waterborne Exterior Flat 541 (44 g/L), MPI # 10.

3. 3rd Coat: Benjamin Moore ben Waterborne Exterior Flat 541 (44 g/L), MPI # 10.

G. Flat Finish - Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Fresh Start High-Hiding All Purpose Primer

046 (44 g/L), MPI # 6, 17, X-Green 17, 39, 50, X-Green 50, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

3. 3rd Coat: Benjamin Moore Regal Select Exterior High-Build Flat Finish N400 (42 g/L) MPI # 10.

J. VINYL SIDING EIFS, SYNTHETIC STUCCO:

1.19 Latex Systems:

1. 1st Coat: Benjamin Moore Fresh Start Multi-Purpose Primer N023 (44 g/L), MPI # 6, 17, X-Green 17, 39, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L)

MPI # 11.

3. 3rd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L)

MPI # 11.

B. Gloss Finish - Vinyl Safe Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Fresh Start Multi-Purpose Primer N023 (44 g/L), MPI # 6, 17, X-Green 17, 39, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L), MPI # 11.

3. 3rd: Coat: Benjamin Moore Ultra Spec EXT Gloss Finish N449 (46 g/L), MPI # 11.

C. Semi-Gloss Finish:

1. 1st Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss

N403 (43 g/L), MPI # 11, 311.

2. 2nd Coat: Benjamin Moore Regal Select Exterior High-Build Soft-Gloss

N403 (43 g/L), MPI # 11, 311.

D. Satin Finish:

1. 1st Coat: Benjamin Moore Fresh Start Multi-Purpose Primer N023 (44 g/L), MPI # 6, 17, X-Green 17, 39, 137, X-Green 137, LEED Credit, CHPS Certified.

Section 09 90 00_13/7

2. 2nd Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI # 15.

3. 3rd Coat: Benjamin Moore Ultra Spec EXT Satin N448 (46 g/L), MPI # 15.

E. Satin Finish - Vinyl Safe Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Fresh Start Multi-Purpose Primer N023 (44 g/L), MPI # 6, 17, X-Green 17, 39, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Regal Select Exterior Revive 544 (36 g/L).

3. 3rd Coat: Regal Select Exterior Revive 544 (36 g/L).

F. Flat Finish:

1. 1st Coat: Benjamin Moore Fresh Start Multi-Purpose Primer N023 (44 g/L), MPI # 6, 17, X-Green 17, 39, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

3. 3rd Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

G. Flat Finish - Vinyl Safe Early Moisture Resistant Finish:

1. 1st Coat: Benjamin Moore Fresh Start Multi-Purpose Primer N023 (44 g/L), MPI # 6, 17, X-Green 17, 39, 137, X-Green 137, LEED Credit, CHPS Certified.

2. 2nd Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

3. 3rd Coat: Benjamin Moore Ultra Spec Exterior Flat Finish N447 (45 g/L), MPI # 10.

PART 3 – EXECUTION

3.1 EXAMINATION

A. Verify that site environmental conditions are appropriate for application of coatings specified.

B. Do not begin installation until substrates have been properly prepared.

C. Immediately prior to coating application, ensure that surfaces to receive coatings are dry.

D. Ensure that moisture-retaining substrates to receive coatings have moisture content within tolerances allowed by coating manufacturer, using moisture measurement techniques recommended by coating manufacturer. Where exceeding the following values, promptly notify Architect and obtain direction before beginning work.

a. Concrete and Masonry: 3-5 percent. Allow new concrete to cure a minimum of 28 days.

b. Exterior Wood: 17 percent.

c. Interior Wood: 15 percent.

d. Interior Finish Detail Woodwork, Including Trim, and Casework: 10 percent.

e. Plaster and Gypsum: 15 percent.

f. Concrete Slab-On-Grade: Perform calcium chloride test over 24 hour period or other acceptable test to manufacturer. Verify acceptable moisture transmission and pH levels.

E. Immediately prior to coating application, examine surfaces to receive coatings for surface imperfections and for contaminants which could impair performance or appearance of coatings, including but not limited to, loose primer, rust, scale, oil grease, mildew, algae, or

Section 09 90 00_14/7 fungus, stains or marks, cracks, indentations, or abrasions.

F. Correct the above conditions and any other conditions which could impair performance or appearance of coatings in accordance with specified surface preparation procedures before proceeding with coating application.

3.2 PREPARATION

A. Do not start work until surfaces to be finished are in proper condition to produce finished surfaces of uniform, satisfactory appearance.

B. Clean surfaces thoroughly prior to coating application.

C. Stains and Marks: Remove completely, if possible, using materials and methods recommended by coating manufacturer; seal with shellac or other coating acceptable to paint manufacturer stains and marks that might bleed through paint finishes which cannot be completely removed.

D. Remove or protect hardware, electrical plates, mechanical grilles and louvers, lighting fixture trim, and other items not indicated to receive coatings which are adjacent to surfaces to receive coatings.

E. Remove mildew from impervious surfaces by scrubbing with solution of trisodium phosphate and bleach. Rinse with clean water and allow substrate to thoroughly dry.

F. Protect adjacent surfaces not indicated to receive coatings.

G. For specific substrate preparation, see “Surface Preparation” at end of Section.

H. Maximize ventilation during application and drying.

I. Isolate area of application from rest of building.

3.3 SURFACE PREPARATION

A. Concrete and Concrete Masonry: Clean surfaces free of loose particles, sand, efflorescence, laitance, form oil, curing compounds, and other substances which could impair coating performance or appearance.

B. Concrete Floors: Remove contaminants which could impair coating performance or appearance. Verify moisture transmission and alkaline-acid balance recommended by coating manufacturer; mechanically abrade surface to achieve 80-100 grit medium-sandpaper texture.

C. Existing Coatings:

a. Remove surface irregularities by scraping or sanding to produce uniform substrate for coating application; apply one coat primer of type recommended by coating manufacturer for maximum coating adhesion.

b. If presence of lead in existing coatings is suspected, cease surface preparation and notify Architect immediately.

D. Gypsum Board: Repair cracks, holes and other surface defects with joint compound to produce surface flush with adjacent surfaces.

E. Masonry Surfaces - Restored: Remove loose particles, sand, efflorescence, laitance, cleaning compounds and other substances that could impair coating performance or appearance.

F. Metals - Aluminum, Mill-Finish: Clean and etch surfaces with a phosphoric acid-water

Section 09 90 00_15/7 solution or water based industrial cleaner. Flush with clean water and allow to dry, before applying primer coat.

G. Metals - Copper: Clean surfaces with pressurized steam, pressurized water, or solvent washing.

H. Metals - Ferrous, Unprimed: Remove rust or scale, if present, by wire brush cleaning, power tool cleaning, or sandblast cleaning; remove grease, oil, and other contaminants which could impair coating performance or appearance by solvent cleaning, with phosphoric-acid solution cleaning of welds, bolts and nuts; spot-prime repaired welds with specified primer.

I. Metals - Ferrous, Shop-Primed: Remove loose primer and rust, if present, by scraping and sanding, feathering edges of cleaned areas to produce uniform flat surface; solvent-clean surfaces and spot-prime bare metal with specified primer, feathering edges to produce uniform flat surface.

J. Metals - Galvanized Steel (not passivated): Clean with a water-based industrial strength cleaner, apply an adhesion promoter followed by a clean water rinse.

Alternately, wipe down surfaces using clean, lint-free cloths saturated with xylene or lacquer thinner; followed by wiping the surface dry using clean, lint-free cloths.

K. Metals - Galvanized Steel, Passivated: Clean with water-based industrial strength cleaner. After the surface has been prepared, apply recommended primer to a small area. Allow primer to cure for 7 days, and test adhesion using the "cross-hatch adhesion tape test" method in accordance with ASTM D 3359. If the adhesion of the primer is positive, proceed with a recommended coating system for galvanized metal.

L. Metals - Stainless Steel: Clean surfaces with pressurized steam, pressurized water, or water-based industrial cleaner.

M. Plaster: Repair cracks, holes and other surface defects as required to maintain proper surface adhesion. Apply patching plaster or Joint compound and sand to produce surface flush with adjacent undamaged surface. Allow a full cure prior to coating application as recommended by the patching compound manufacturer's recommendations.

N. Polyvinyl Chloride (PVC) Pipe: remove contaminants and markings with denatured alcohol scuff sand and wipe with solvent for maximum adhesion. Test adhesion before starting the job.

O. Fiberglass Doors - remove contaminants with cleaning solvent (alcohol) scuff sand and wipe. Test adhesion of primer before starting job.

P. Textiles - Insulated Coverings, Canvas or Cotton: Clean using high-pressure air and solvent of type recommended for material.

Q. Wood:

a. Seal knots, pitch streaks, and sap areas with sealer recommended by coating manufacturer; fill nail recesses and cracks with filler recommended by coating manufacturer; sand surfaces smooth.

b. Remove mill marks and ink stamped grade marks.

c. Apply primer coat to back of wood trim and paneling.

R. Wood Doors: Seal door tops and bottoms prior to finishing.

S. Wood Doors - Field-Glazed Frames and Sash: Prime or seal glazing channels prior to glazing.

Section 09 90 00_16/7

3.4 APPLICATION

A. General:

A. Apply paint in accordance with manufacturer's directions. Use applicators and techniques best suited to substrate and type of material being applied. Do not use roller or spray for wood and plywood, or roller for metal, unless specifically approved by the Contracting Officer.

B. Apply additional coats when undercoats, stains or other conditions show through final coat of paint, until paint film is of uniform finish, color and appearance. Give special attention to insure that surfaces, including edges, corners, crevices, welds, and exposed fasteners receive a dry film thickness equivalent to that of flat surfaces.

C. Paint surfaces behind movable equipment and furniture same as similar exposed surfaces.

D. Paint back sides of access panels, and removable or hinged covers to match exposed surfaces.

E. Sand lightly between each succeeding enamel or varnish coat.

F. Omit first coat (primer) on metal surfaces which have been shop-primed and touch-up painted, unless otherwise indicated. Spot prime any damaged areas.

B. Scheduling Painting:

A. Apply first coat material to surfaces that have been cleaned, pretreated, or otherwise prepared for painting as soon as practicable after preparation and before subsequent surface deterioration.

B. Allow sufficient time between successive coatings to permit proper drying. Do not recoat until paint has dried to where it feels firm, does not deform, or feel sticky under moderate thumb pressure, and application of another coat of paint does not cause lifting or loss of adhesion of the undercoat.

C. Minimum Coating Thickness:

A. Apply materials at not less than manufacturer's recommended spreading rate, to provide a dry film thickness per coat as indicated, or if not indicated, as recommended by coating manufacturer.

D. Mechanical and Electrical Work:

A. Mechanical items to be painted include, but are not limited to, the following (where present):

a. Piping and supports, roof vents, louvers, grilles, registers, fans and curbs.

B. Electrical items to be painted include, but are not limited to, the following (where present):

a. Conduit, boxes and fittings, exposed panelboard surfaces, including covers.

E. Prime Coats:

A. Apply prime coat to material which is required to be painted or finished, and which has not been prime coated by others.

Section 09 90 00_17/7

B. Recoat primed and sealed surfaces where there is evidence of suction spots or unsealed areas in first coat, to assure a finish coat with no burn-through or other defects due to insufficient sealing.

F. Pigmented (Opaque) Finishes:

A. Completely cover to provide an opaque, smooth surface of uniform finish, color, appearance and coverage. Cloudiness, spotting, holidays, laps, brush marks, runs, sags, ropiness, or other surface imperfections will not be acceptable. Cut in sharp lines and color breaks.

3.5 CLEANING

A. During progress of work, remove from site discarded paint materials, rubbish cans and rags at end of each work day.

B. Upon completion of painting work, clean window glass and other paint-spattered surfaces.

Remove spattered paint by proper method of washing and scraping, using care not to scratch or otherwise damage finished surfaces.

C. At the completion of work of other trades, touch-up and restore all damaged or defaced painted surfaces.

D. Vacate space for as long as possible after application. Wait a minimum of 48 hours before occupying freshly painted rooms.

3.6 PROTECTION

A. Protect work of other trades against damage from paint application. Correct damage to work of other trades by cleaning, repairing, replacing, and refinishing, as approved by Contracting Officer, and leave in an undamaged condition.

B. Provide "Wet Paint" signs as required to protect newly painted finishes. Remove temporary protective wrappings provided by others for protection of their work after completion of painting operations.

3.7 SURFACE PREPARATION

A. Comply with manufacturer's written instructions and recommendations in "MPI Architectural Painting Specification Manual" applicable to substrates and paint systems indicated.

B. Clean substrates of substances that could impair bond of paints, including dirt, oil, grease, and incompatible paints and encapsulants.

C. Remove incompatible primers and reprime substrate with compatible primers as required to produce paint systems indicated.

3.8 SCHEDULE

A. If paint on walls is to be applied using spray technique, the final coat shall be backrolled to ensure even distribution.

B. Paint all exposed ductwork and electrical conduit where exposed ceilings occur (use a flat finish in lieu of scheduled paint).

C. Paint all existing door frames indicated to remain. Existing doors to remain shall be refinished and painted. All other existing surfaces to be painted shall be as indicated on

Section 09 90 00_18/7

Drawings.

D. Paint / stain all millwork not to receive surfacing as indicated on Drawings. Coordinate with Division 6 Sections “Finish Carpentry” and “Interior Architectural Woodwork”.

END OF SECTION