Attachment_10-Updated_BLDG._886_Drawings_8_July_2019.pdf
PDF 11 MB Posted
- Attached to
- Renovate Bldg 886 Federal contract opportunity
- Solicitation number
- FA282319RA012
About this file
Attachment 10-Updated Bldg. 886 Drawings 8 July 2019
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DORM 19
COASTAL
EAST GATE
SHOPETTE
DORM 855
ADDIE R LEWIS SCHOOL
VISITING AMN QTRS
AAFES CAR CARE
NAVY EOD DORM
SWIMMING
POOL
LAUNDRY
DINING
FACILITY
DORM 854
HOBBY SHOP
EAST GATE
GYM
TAXILANE M EAST
TAXILANE T
GENERAL AVIATION RAMP
NE U
TA
XI
LA
N
E S
WASH
RACK
HG-3
TW
U
AEROCLUB
G-1
HUNG ORD/GUN CLEARING
ORD/GUN CLEARING
338°
E G
LI
N
B
LV
D
MCCARTHY AV
W
IC
KE
R
ST
DADE RD
"D " A
V
LOUISIANA AVE
TENNESSEE AVE
CHOCTAWHATCHEE RD
DAYTONA R
D
W E
S C
A M
BI
A
R D
CHEROKEE AV
EGLIN RD
O
KE
EC
H
O
BE
E R
D
S
AN
TA
R
O S
A R
D
ORGIA
A
V
DA
YT
O
NA
R D
EIGHTH ST
W
IC
KE
R
C I R
SEVENTH ST
SUWANEE
R
IM
ETER
R
D
O
CA
LA
R
D
PERIMET
DAY
TO
NA
RD
S
EM
IN
O
LE R
D
TENTH ST
FL
O
R
ID
A A
V
W
IC
KE
R
C R
HY
M
ES
R
D
CHAPEL 1
846T
87534
891945
BUS
889 890
85T
8587172
EG
LIN
B
LV
D
EIGHTH
FTFA-17-1100
RENOVATE BUILDING 886
EGLIN AFB, FLORIDA
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
AS-BUILT
STATE
OF
FLORIDA
GENERAL NOTESGENERAL DEMOLITION NOTESGENERAL ABBREVIATIONS
DRAWING SYMBOLS LEGEND BID OPTIONS
BASE CIVIL ENGINEER
BASE CIVIL ENGINEER
1.00 GENERAL NOTES
1.01 THESE STRUCTURAL NOTES SHALL BE APPLIED WITH THE TECHNICAL SPECIFICATIONS IN THE SPECIFICATIONS MANUAL. ANY CONFLICTING REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION
OF THE CONTRACTING OFFICER FOR RESOLUTION BEFORE PROCEEDING WITH FABRICATION OR
CONSTRUCTION.
1.02 DRAWINGS SHOW TYPICAL AND CERTAIN SPECIFIC CONDITIONS ONLY. FOR DETAILS NOT
SPECIFICALLY SHOWN, PROVIDE DETAILS SIMILAR TO THOSE SHOWN.
1.03 VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE STARTING WORK. NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCY.
1.04 THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC., ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. TAKE NECESSARY PRECAUTIONS TO PROTECT THE EXISTING STRUCTURE AND ITS FOUNDATION AND TO LIMIT, TO THE EXTENT POSSIBLE, THE EFFECTS OF CONSTRUCTION THAT THE NEW STRUCTURE HAS ON THE EXISTING STRUCTURE.
1.05 COORDINATE STRUCTURAL CONTRACT DOCUMENTS WITH ARCHITECTURAL, MECHANICAL,
ELECTRICAL, PLUMBING AND CIVIL. NOTIFY CONTRACTING OFFICER OF ANY CONFLICT AND/OR OMISSION. CONTRACTOR SHALL MAKE NO DEVIATION FROM DESIGN DRAWINGS WITHOUT WRITTEN
APPROVAL OF THE ARCHITECT. FOR ADDITIONAL OPENINGS NOT SHOWN ON THE STRUCTURAL
DRAWINGS, SEE ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS.
1.06 DESIGN CRITERIA:
THE STRUCTURE HAS BEEN DESIGNED UTILIZING THE FOLLOWING REFERENCES:
A. UFC 1&200&01, GENERAL BUILDING REQUIREMENTS
B. UFC 3&301&01, STRUCTURAL ENGINEERING, WITH CHANGE 1
C. INTERNATIONAL BUILDING CODE, 2012
D. ASCE 7&10, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
E. ACI 302.1 R&5, CONCRETE FLOOR AND SLAB CONSTRUCTION
F. ACI 318&11, BUILDING CODE REQUIREMENTS FOR CONCRETE STRUCTURES
G. ACI 360 R&06, DESIGN OF SLAB ON GRADES
1.07 DESIGN LOADS:
A. DEAD LOADS:
1. SELF WEIGHT OF 8” SLAB: 100 PSF
2. SELF WEIGHT OF 4” SLAB: 50 PSF
B. LIVE LOADS: (MAY BE REDUCED PER CODE)
1. RAMPS: 100 PSF
2. SLAB&ON&GRADE: 100 PSF
3. HEAVY TRAFFIC AREA OR 6&TON FORKLIFT: 250 PSF
C. WIND LOADS & STRUCTURE HAS BEEN DESIGNED TO CONFORM TO THE WIND PROVISIONS OF
ASCE 7&10. SEE WIND PRESSURE DIAGRAM & CHART FOR THE FOLLOWING:
1. BASIC WIND SPEED (3&SEC GUST)
2. BUILDING RISK CATEGORY
3. WIND EXPOSURE CATEGORY
4. INTERNAL PRESSURE COEFFICIENT
5. COMPONENT & CLADDING WIND PRESSURES
1.08 SHOP DRAWING SUBMITTALS:
A. THE REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS DONE BY THE CONTRACTING OFFICER
DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO REVIEW AND CHECK SHOP
DRAWINGS BEFORE SUBMITTAL TO THE STRUCUTRAL ENGINEER. THE REVIEW BY THE
STRUCUTRAL ENGINEER IS FOR GENERAL CONFORMANCE ONLY. IF SHOP DRAWINGS HAVE
NOT BEEN REVIEWED AND APPROVED BEFORE SUBMITTAL TO THE STRUCUTURAL ENGINEER,
THEY SHALL BE RETURNED WITHOUT APPROVAL.
B. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ANY AND ALL ERRORS AND OMISSIONS
ASSOCIATED WITH THE PREPARATION OF ALL SHOP DRAWINGS IN RELATIONSHIP TO THE
CONSTRUCTION DOCUMENTS.
C. ALL MODIFICATIONS MADE FOR SUBMITTALS THAT ARE RE&SUBMITTED SHALL CLEARLY NOTE
ALL CHANGES.
D. REPRODUCING THE CONTRACT DOCUMENTS FOR USE AS SHOP DRAWINGS IS NOT ALLOWED,
AND SHOP DRAWINGS WILL BE RETURNED WITHOUT APPROVAL.
E. GENERAL SHOP DRAWING REQUIREMENTS:
1. SUBMIT SHOP DRAWINGS AND ANY OTHER SPECIAL INFORMATION NECCESSARY FOR
PROPER FABRICATION, ERECTION, AND PLACEMENT OF STRUCTURAL FABRICATIONS.
INCLUDE PLANS, ELEVATIONS, AND SECTIONS. CLEARLY SHOW ANCHORAGES,
CONNECTIONS, AND ACCESSORY ITEMS. THE DETAILER MUST INTERPRET THE
CONTRACT DOCUMENTS AND CLEARLY CONVEY THIS INTERPRETATION TO THE FIELD IN
THE FORM OF PLACING OR ERECTION DRAWINGS.
2. CONCRETE REINFORCING DETAILER & PROVIDE PLACING DRAWINGS FOR FABRICATION
AND PLACING OF REINFORCING STEEL. THESE DRAWINGS SHALL INCLUDE, BUT ARE NOT
LIMITED TO, THE FOLLOWING: BAR LISTS, SCHEDULES, BENDING DETAILS, PLACING
DETAILS, PLACING PLANS, AND PLACING ELEVATIONS. CLEARLY SHOW FOUNDATION
REINFORCING. INDICATE BAR LENGTHS, LOCATION AND SPLICES OF CONTINUOUS BARS,
AND BAR SUPPORTS. CLEARLY SHOW LOCATIONS OF ALL DOWELS ON PLAN.
2.00 FOUNDATIONS AND SLAB&ON&GRADE
2.01 SHALLOW FOUNDATIONS HAVE BEEN DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF
1500 PSF.
2.02 AT THIS TIME NO GEOTECHNICAL REPORT HAS BEEN SUBMITTED. AN ALLOWABLE SOIL BEARING PRESSURE HAS BEEN CONSERVATIVELY ESTIMATED BASED ON SIMILAR PROJECTS OF THIS SIZE AND LOCATED IN THE SAME GENERAL AREA OF CONSTRUCTION. A QUALIFIED GEOTECHNICAL ENGINEER SHALL CHECK COMPACTION OF THE FOOTINGS. THE SOILS IMMEDIATELY BENEATH ALL FOOTINGS SHOULD BE COMPACTED FOR A MINIMUM DEPTH OF 12 INCHES TO A MINIMUM OF 95% OF THE SOIL’S MAXIMUM DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D1557) USING A LARGE
TAMPER.
2.03 A QUALIFIED GEOTECHNICAL ENGINEER SHALL VERIFY CONDITION AND/OR ADEQUACY OF ALL
SUBGRADES, FILLS AND BACKFILLS BEFORE PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS,
WALLS, FILLS, BACKFILLS, ETC. SHOULD THE CONTRACTOR FIND UNDESIRABLE SOILS, HE SHALL STOP WORK AND IMMEDIATELY CONTACT CONTRACTING OFFICER . ALL FOOTINGS SHALL REST EITHER ON UNDISTURBED SOIL OR A MANUALLY OPERATED VIBRATORY SLED OR TAMPER SHOULD BE USED TO
DENSIFY ANY SOILS IN THE BOTTOM OF THE FOOTING TRENCHES LOOSENED DURING THE
EXCAVATION OPERATION.
2.04 SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS PERMIT EARTH FORMING.
FOUNDATIONS POURED AGAINST THE EARTH REQUIRE THE FOLLOWING PRECAUTIONS: SLOPE SIDES OF EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER AND CLEAN UP SLOUGHING BEFORE
AND DURING CONCRETE PLACEMENT.
2.05 CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY PROTECTING ALL EXCAVATION SLOPES.
2.06 DEWATER TO AT LEAST TWO FEET BELOW BOTTOM OF LOWEST FOUNDATION IF GROUNDWATER IS
ENCOUNTERED.
2.07 SLAB&ON&GRADE REQUIREMENTS:
A. UNLESS NOTED OTHERWISE, THE SLAB&ON&GRADE SHALL BE A MINIMUM OF 4 INCHES THICK, PLACED ON COMPACTED SUBGRADE, AND REINFORCED WITH 6 x 6 & W2.0 x W2.0 WWF IN FLAT
SHEETS (ROLLS ARE NOT PERMITTED). PROVIDE POSITIVE SUPPORT 2½” CLEAR FROM BOTTOM
OF SLAB. LAP MESH 12”.
B. PLACE CONTROL OR CONSTRUCTION JOINTS AT LOCATIONS INDICATED BY “C.J.” IF NOT
INDICATED, LOCATED JOINTS AT COLUMN CENTERLINES AND AT 20’&0” O.C MAX. SAWCUT
CONTROL JOINTS AS SOON AFTER POURING AS POSSIBLE, WHEN CONCRETE WILL NOT RAVEL;
12 HRS. MAX. CURE CONCRETE IN ACCORDANCE WITH ACI 301. BEGIN CURING IMMEDIATELY
AFTER POURING TO LIMIT CRACKING PRIOR TO SAWCUTTING CONTROL JOINTS.
C. THE TOP 12” OF THE SUBGRADE SHALL BE COMPACTED TO 95% OF THE MAXIMUM MODIFIED
PROCTOR DENSITY. DENSITY TESTS SHALL BE TAKEN AT 2500 SF INTERVALS.
D. VAPOR RETARDER IS ONLY REQUIRED OVER GEOFOAM. SEE SPECIFICATIONS FOR VAPOR
RETARDER MATERIAL. VAPOR RETARDER SHALL CONFORM TO ASTM E1745, CLASS A AND BE A
MINIMUM OF 15 MIL. THICKNESS. THE VAPOR RETARDER SHOULD BE PLACED OVER THE
GEOFOAM. VAPOR RETARDER SHOULD BE OVERLAPPED 8 IN. AND TAPED AT THE JOINTS AND
CAREFULLY FITTED AROUND SERVICE OPENINGS.
3.00 REINFORCED CONCRETE
3.01 ALL CONCRETE WORK SHALL CONFORM TO ACI 301&05, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. DESIGN IS BASED ON ACI 318&05, BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. DETAIL CONCRETE REINFORCEMENT AND ACCESSORIES IN ACCORDANCE WITH ACI 315, DETAILING MANUAL. DETAIL ALL CONCRETE WALLS AND BEAMS ON THE SHOP DRAWINGS IN
ELEVATION UNLESS SPECIFICALLY APPROVED OTHERWISE. SUBMIT SHOP DRAWINGS FOR APPROVAL, SHOWING ALL FABRICATION DIMENSIONS AND LOCATIONS FOR PLACING REINFORCING STEEL AND
ACCESSORIES. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND
REVIEWED.
3.02 UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL WEIGHT AND HAVE THE FOLLOWING
MINIMUM 28 DAY COMPRESSIVE STRENGTHS:
A. FOUNDATIONS 3000 PSI
B. RETAINING WALLS 4000 PSI
C. SLAB&ON&GRADE 4000 PSI
D. COLUMNS AND PIERS 4000 PSI
ALL CONCRETE SHALL HAVE ENTRAINED AIR, U.N.O. CONCRETE MAY CONTAIN A PROPERLY DESIGNED
SUPERPLASTICIZER FOR WORKABILITY.
3.03 REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 UNLESS NOTED OTHERWISE.
3.04 THE PROPOSED MATERIALS AND MIX DESIGN SHALL BE FULLY DOCUMENTED AND REVIEWED BY THE OWNER'S TESTING LABORATORY. RESPONSIBILITY FOR OBTAINING THE REQUIRED DESIGN STRENGTH
IS THE CONTRACTOR'S.
3.05 USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IN CONCRETE IS NOT PERMITTED.
3.06 HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED ONLY WHERE INDICATED. THE STRUCTURAL ENGINEER SHALL APPROVE THE LOCATION OF VERTICAL CONSTRUCTION JOINTS. CONSTRUCTION JOINTS SHALL BE THOROUGHLY ROUGHENED BY MECHANICAL MEANS, AND CLEANED. CONTRACTOR
SHALL SUBMIT DRAWINGS SHOWING INTENDED POURING SEQUENCE AND LOCATION OF
CONSTRUCTION JOINT TO THE ENGINEER FOR REVIEW. PROPOSED METHODS MUST BE ACCEPTABLE
TO THE ARCHITECT BEFORE USE.
3.07 UNLESS NOTED OTHERWISE, PLACE VERTICAL CONTROL JOINTS IN CONCRETE WALLS AT 10'&0" O.C.
(MAX), 3/4" DEEP, V&CHAMFERED ON BOTH FACES. CONSTRUCTION JOINTS SHALL FALL ON CONTROL JOINTS AND SHALL BE KEYED. STOP 50 PERCENT OF THE SPECIFIED LONGITUDINAL REINFORCEMENT
AT THE CONTROL JOINT.
3.08 CHAMFER OR ROUND ALL EXPOSED CORNERS A MINIMUM OF 3/4".
3.09 TIE ALL REINFORCING STEEL AND EMBEDMENTS SECURELY IN PLACE PRIOR TO PLACING CONCRETE.
PROVIDE SUFFICIENT SUPPORTS TO MAINTAIN THE POSITION OF REINFORCEMENT WITHIN SPECIFIED TOLERANCE DURING ALL CONSTRUCTION ACTIVITIES. "STICKING” DOWELS INTO WET CONCRETE IS
NOT PERMITTED.
3.10 PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE; SPLICE ONLY AS SHOWN OR
APPROVED; STAGGER SPLICE WHERE POSSIBLE; USE FULL TENSION SPLICE (CLASS "B") UNLESS
NOTED OTHERWISE. DOWELS SHALL MATCH THE SIZE AND SPACING OF THE SPECIFIED
REINFORCEMENT AND SHALL BE LAPPED WITH FULL TENSION SPLICES (CLASS "B") UNLESS NOTED
OTHERWISE. TERMINATE BARS WITH STANDARD HOOKS.
3.11 REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE COVER UNLESS NOTED OTHERWISE
(PER ACI 318&05 PAR.7.7.1):
A. CONCRETE AGAINST EARTH (NOT FORMED): 3"
B. FORMED CONCRETE EXPOSED TO THE EARTH OR WEATHER:
1. #6 THROUGH #18 BARS: 2"
2. #5 BARS AND SMALLER: 1&1/2"
C. CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
1. SLABS AND WALLS: 1"
2. BEAMS (STIRRUPS) AND COLUMNS (TIES): 1&1/2"
3.12 DO NOT PLACE DUCTS EXCEEDING ONE&THIRD THE SLAB OR WALL THICKNESS WITHIN THE SLAB OR
WALL UNLESS SPECIFICALLY SHOWN AND DETAILED ON STRUCTURAL DRAWINGS.
3.13 DO NOT WELD OR TACK WELD REINFORCING STEEL UNLESS APPROVED OR DIRECTED BY THE
CONTRACTING OFFICER.
3.14 ALL REINFORCING STEEL PLACEMENTS SHALL BE REVIEWED BY A REGISTERED STRUCTURAL
ENGINEER, OR BY A REPRESENTATIVE RESPONSIBLE TO HIM. (RE: ACI 318 PAR. 1.3.1)
4.00 STRUCTURAL STEEL
4.01 STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED ACCORDING TO AISC
"SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, ASD, LATEST EDITION.
4.02 SUBMIT SHOP DRAWINGS PREPARED IN ACCORDANCE WITH AISC MANUAL "DETAILING FOR STEEL CONSTRUCTION", LATEST EDITION. STEEL FABRICATOR SHALL SUPPLY ANCHOR BOLT LOCATION DRAWINGS. DO NOT BEGIN FABRICATION UNTIL SHOP DRAWINGS ARE COMPLETED AND REVIEWED.
4.03 HEADED STUD SHEAR CONNECTORS (INDICATED AS “HS” ON PLANS): ASTM A 108, GRADES 1010 THROUGH 1020, HEADED&STUD TYPE, COLD&FINISHED CARBON STEEL; AWS D1.1, TYPE B. USE
AUTOMATIC END WELDING OF HEADED&STUD SHEAR CONNECTORS ACCORDING TO AWS D1.1 AND
MANUFACTURER’S WRITTEN INSTRUCTIONS.
4.04 STRUCTURAL STEEL SHAPES, PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36
UNLESS NOTED OTHERWISE.
5.00 COLD FORMED METAL FRAMING SEE SEPARATE SECTION BELOW FOR METAL TRUSSES
5.01 COLD FORMED METAL STUDS: GALVANIZED STEEL PER ASTM A525, G60 COATING MEETING THE
REQUIREMENTS OF ASTM A446 GRADE A, WITH A MINIMUM YIELD STRENGTH OF 33,000 PSI.
5.02 ALL STUDS INDICATED SHALL HAVE 1&5/8” WIDE FLANGES WITH A ½” LIP.
ALL TRACK INDICATED SHALL HAVE 1&1/4” WIDE FLANGES.
5.03 STUDS SHALL BE LOCATED DIRECTLY BELOW ROOF TRUSSES.
5.04 GABLE END WALLS SHALL BE FRAMED FULL HEIGHT.
5.05 TOP AND BOTTOM TRACKS SHALL BE 18 GA. MINIMUM. TRACKS SHALL BE CONTINUOUS AND LAP SPLICED WITH A 22" PIECE OF 20 GA. TRACK AND 6 #10 SCREWS EACH SIDE OF SPLICE. LOCATE SPLICE
MIDWAY BETWEEN STUDS.
5.06 INTERIOR WALLS:
WALL STUDS TO BE 6", 18&GAUGE STUDS SPACED 16" ON CENTER.
WALL HEIGHT SHALL NOT EXCEED 14&FT. PROVIDE LATERAL BRIDGING AT 48" ON CENTER OVER FULL
HEIGHT OF WALL
a a
5 5 a a
WIND LOAD DETERMINATION ASSUMPTIONS & INTERNATIONAL BUILDING CODE 2015
ROOF SLOPE
142 C 13.8 3 ON 12 II ENCLOSED
ULTIMATE DESIGN WIND PRESSURES FOR COMPONENTS AND CLADDING (PSF)
ROOF ZONE 1
ROOF ZONE 2 ROOF ZONE 3
WALL ZONE 4 WALL ZONE 5
O&HANG O&HANG
25.3 &40.2 &70.0 44.0 &47.7 &58.8
50 20.1 &37.6 &57.0 39.4 &43.1 &49.7
17.9 &36.5 &51.4 37.4 &41.1 &45.7
&103.5
&87.9
&81.2
&137.8
&106.6
&93.1
NOTES:
1. FOR EFFECTIVE AREAS BETWEEN THOSE GIVEN ABOVE THE LOAD MAY BE INTERPOLATED,
OTHERWISE USE THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA.
2. THE EDGE STRIP, a = 5.5 FT.
3. PRESSURES SHALL BE APPLIED IN ACCORDANCE WITH THE FIGURE SHOWN ON THIS SHEET.
< 10
> 100
WIND VELOCITY
(MPH)
EXPOSURE
CATEGORY
MEAN ROOF
HEIGHT (FT.)
RISK
CATEGORY
ENCLOSURE
CATEGORY
EFF.
AREA
(SQ. FT)
4. PRESSURES GIVEN ARE ULTIMATE LOADS TO BE USED WITH STRENGTH DESIGN. FOR
SERVICE LOADS TO BE USED WITH ALLOWABLE STRESS DESIGN, MULTIPLY THE PRESSURES
BY 0.60. SEE TABLES 2.3 AND 2.4 IN ASCE 7&10 FOR MORE INFORMATION ON LOAD
COMBINATIONS.
&81.9
&81.9
&81.9
25.3
20.1
17.9
25.3
20.1
17.9
44.0
39.4
37.4
REPRESENTATIVE DIAGRAM
ATFP DESIGN CRITERIA PER UFC 4&010&01 DATED 9 FEBRUARY 2012, CHANGE 1, 1 OCTOBER 2013
BUILDING LOCATION: WITHIN CONTROLLED PERIMETER
BUILDING OCCUPANCY CATEGORY: LOW OCCUPANCY
LEVEL OF PROTECTION: LOW
EXPLOSIVE WEIGHT: TYPE II
PER UFC 4&010&01 LOW OCCUPANCY BUILDING IS CLASSIFIED AS ANY BUILDING OR PORTION OF A BUILDING ROUTINELY OCCUPIED BY FEWER THAN 11 DOD PERSONNEL OR WITH A POPULATION DENSITY OF LESS THAN
ONE PERSON PER 40 GROSS SQUARE FEET (40 GROSS SQUARE METERS).
1&9.1 LOW OCCUPANCY BUILDINGS: BUILDING WHOSE OCCUPANCIES DO NOT MEET THE OCCUPANCY LEVELS OF INHABITED OR PRIMARY GATHERING BUILDINGS OR OF BILLETING ARE EXEMPT FROM ALL PROVISIONS OF THESE
STANDARDS.
BUILDING 886 WIND LOAD INFORMATION
a
5 5 a a
1 a
WIND LOAD DETERMINATION ASSUMPTIONS & INTERNATIONAL BUILDING CODE 2015
ROOF SLOPE
132 C 15.0 0.25 ON 12 I OPEN
ULTIMATE DESIGN WIND PRESSURES FOR COMPONENTS AND CLADDING (PSF)
ROOF
ZONE 1
ROOF
ZONE 2
ROOF
ZONE 3
32.4 &30.5 &46.9
>9, <36
&91.6
&46.9
&30.5
NOTES:
1. FOR EFFECTIVE AREAS BETWEEN THOSE GIVEN ABOVE THE LOAD MAY BE INTERPOLATED,
OTHERWISE USE THE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA.
2. THE EDGE STRIP, a = 3.0 FT.
3. PRESSURES SHALL BE APPLIED IN ACCORDANCE WITH THE FIGURE SHOWN ON THIS SHEET.
<9
>36
WIND VELOCITY
(MPH)
EXPOSURE
CATEGORY
MEAN ROOF
HEIGHT (FT.)
RISK
CATEGORY
ENCLOSURE
CATEGORY
EFF.
AREA
(SQ. FT)
4. PRESSURES GIVEN ARE ULTIMATE LOADS TO BE USED WITH STRENGTH DESIGN. FOR
SERVICE LOADS TO BE USED WITH ALLOWABLE STRESS DESIGN, MULTIPLY THE PRESSURES
BY 0.60. SEE TABLES 2.3 AND 2.4 IN ASCE 7&10 FOR MORE INFORMATION ON LOAD
COMBINATIONS.
48.8 64.8
48.8
32.4
REPRESENTATIVE DIAGRAM
CANOPY WIND LOAD INFORMATION
32.4
32.4 32.4
48.8&30.5
&30.5
&46.9
&30.5
WINDWARD
FASCIA
LEEWARD
FASCIA
48.3 &32.2
AS�BUILT
96 CEG, OFFICE FORM 002, FY2018
DATEREVISION BY APPR'D
PROGRAM MANAGER
ENVIROMENTAL
INDEX NO.
CENM
APPROVED
APPROVED
APPROVED
SIGNATURE
DATE
USING AGENCY
APPROVED
APPROVED
COMMUNICATIONS
OPERATIONS ENGINEERING
APPROVED
APPROVED
APPROVED
APPROVED
FIRE PREVENTION
SAFETY REPRESENTATIVE
DIR. BASE MED. SERVICE
PROJ. ENGR.
DRAWN BY TITLE
CONTENTS
APPROVED
SCALE
DATE
96 CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
SPEC. NO. PROJ. NO. DRAWING NO. FILE NO.
SHEET OFFTFA
DESCRIPTION
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
APPROVED
D
EU
SOJ
R E
G
ISTERE
R E
E
NIGNED
EPH
ER
IL
SI
U
OL
A
DIOL
F R
STATE OF
No. 54319
E T
ACFIT
C R
E
I
301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501
JOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLC S T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SJDA
STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA
P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515
JULY,2019
J. SUMRALL
L. DeREUIL
Hernandez Calhoun Design International Architecture ● Interior Design
RENOVATE
BUILDING 886
EGLIN, AFB,FLORIDA
17�1100 XXXX17AP
Hernandez Calhoun Design International Architecture ● Interior Design 17AP
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199
7/12/20197/12/20197/12/20197/12/2019
S-1
GENERAL NOTES
A
A
B
B
C
C
D
D
E
E
F
F
G
G
H
H
I
I
J
J
K
K
L
L
S-3
S-3
S-3
S-3
S-3
13'&6" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 13'&8" 6'&7 3/4"
'&0
'&4
'&0
S-5
7'&0"
6' &0
7" SLAB
4" SLAB4" SLAB
4" SLAB
4" SLAB
7" SLAB
&1'&7 1/2"
S-5
7" SLAB
S-5
Sim
S-5
Sim
S-6
S-5
S-5
Sim
S-5
Sim
7" SLAB
9' &9
S-5
S-5
S-6
S-6
A B C D E F G H I J K L S-4
13'&6" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 15'&0" 13'&8" 6'&7 3/4"
S-6
7" SLAB7" SLAB9'
&6
S-5
S-5
4" SLAB
4" SLAB
LEGEND
= CONSTRUCTION JOINT; PLACE C.J. AT 15'-0" O.C. MAXIMUM SPACING. CUT 50% OF REINF. AT
JOINTS. PROVIDE VERTICAL WALL JOINTS AT HORIZONTAL JOINT LOCATIONS, TYPICAL.
C.J.
= 8" CONCRETE WALL. WALL SHALL BE REINFORCED WITH #4 VERTICAL REINFORCING AT 1'-0" ON
CENTER IN CENTER OF 8" WALL & WITH #4 HORIZONTAL REINFORCING AT 0'-8" ON CENTER.
= SLAB DEPRESSION; SEE PLAN FOR DEPRESSION EXTENTS AND DEPRESSION DEPTH AT DOCK
LEVELER.
&X'&X"
7" MINIMUM THICKNESS SLAB-ON-GRADE REINFORCED WITH #4 BARS @ 8" O.C. BOTTOM BARS EACH WAY WITH 2" CLR. TO BOT. 7" SLABS WILL REQUIRE DOWELLED JOINTS, WHICH WILL REQUIRE (2) POURS7" SLAB =
4" MINIMUM THICKNESS SLAB-ON-GRADE REINFORCED WITH WWF 6x6 W2.0xW2.0 WITH 2" CLR.
POSITIVE SUPPORT FROM BOTTOM OF SLAB.
4" SLAB =
(2) #4x4'-0" RE-ENTRANT CRACK CONTROL REINF. W/ 1-1/2"
CLR TO TOP OF SLAB
= VERTICAL CONCRETE WALL CONTROL JOINT LOCATION (15 FT MAXIMUM SPACING); SEE TYPICAL DETAILS ON S&7
AS�BUILT
96 CEG, OFFICE FORM 002, FY2018
DATEREVISION BY APPR'D
PROGRAM MANAGER
ENVIROMENTAL
INDEX NO.
CENM
APPROVED
APPROVED
APPROVED
SIGNATURE
DATE
USING AGENCY
APPROVED
APPROVED
COMMUNICATIONS
OPERATIONS ENGINEERING
APPROVED
APPROVED
APPROVED
APPROVED
FIRE PREVENTION
SAFETY REPRESENTATIVE
DIR. BASE MED. SERVICE
PROJ. ENGR.
DRAWN BY TITLE
CONTENTS
APPROVED
SCALE
DATE
96 CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
SPEC. NO. PROJ. NO. DRAWING NO. FILE NO.
SHEET OFFTFA
DESCRIPTION
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
APPROVED
D
EU
SOJ
R E
G
ISTERE
R E
E
NIGNED
EPH
ER
IL
SI
U
OL
A
DIOL
F R
STATE OF
No. 54319
E T
ACFIT
C R
E
I
301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501
JOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLC S T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SJDA
STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA
P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515
JULY,2019
J. SUMRALL
L. DeREUIL
Hernandez Calhoun Design International Architecture ● Interior Design
RENOVATE
BUILDING 886
EGLIN, AFB,FLORIDA
17�1100 XXXX17AP
Hernandez Calhoun Design International Architecture ● Interior Design 17AP
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199
7/12/20197/12/20197/12/20197/12/2019
S-2
OVERALL PLAN
1/8" = 1'-0"S-2
1 BLDG. 886 DOCK REPAIR - BASE BID
1/8" = 1'-0"S-2
2 BLDG. 886 DOCK REPAIR - BID OPTION
C
S-5
4" SLAB
1/4
7'&0"
6' &0
G H
4" SLAB
1/4" / 1' - 0"
7'&0"
6' &0
S-5
Sim
I J
1/4" / 1' - 0"
C.J.
DOCK
LEVELER
7" SLAB
C.J.
C.J.
C .J
C .J
10'&0" 10'&0" 10'&0"
S-5
7" SLAB
S-5
S-6
S-6
1/4" / 1' - 0"
/4
S-6
30'&0"
'&0
1'&3" 16'&4 1/2" 11'&1 1/2" 1'&3"
1' &3
'&7
/2
ALUMINUM CANOPY
COLUMN BLOCKOUT
LOCATIONS
PROVIDE 4'0"x2&6"' x 2'&0" DEEP
UNREINFORCED CONCRETE FOOTING
FOR CENTER COLUMN SUPPORT.
TYP.
A B C
/4
1/4" / 1' - 0"
1/4" / 1' - 0"
/4
1" / 1' - 0"
1/4" / 1' - 0"
1" / 1' - 0"
4" SLAB
4" SLAB
8'&0" 6'&8" 6'&8" 6'&8"
4' &0
9'
&6
C .J
C .J
C .J
C .J
C .J
C .J
C .J
C
.J
C .J
C.J.
S-6
ALUMINUM CANOPY
COLUMN BLOCKOUT
LOCATIONS
PROVIDE 4'0"x2&6"' x 2'&0" DEEP
UNREINFORCED CONCRETE FOOTING
FOR CENTER COLUMN SUPPORT.
(TYP. 5X)
5'&0"
S-6
I J K L
7" SLAB
/4
C .J
C .J
15' & 0" 15' & 0" 13' & 8" 6' & 7 3/4"
S-5
/4
LEGEND
= CONSTRUCTION JOINT; PLACE C.J. AT 15'-0" O.C. MAXIMUM SPACING. CUT 50% OF REINF. AT
JOINTS. PROVIDE VERTICAL WALL JOINTS AT HORIZONTAL JOINT LOCATIONS, TYPICAL.
C.J.
= 8" CONCRETE WALL. WALL SHALL BE REINFORCED WITH #4 VERTICAL REINFORCING AT 1'-0" ON
CENTER IN CENTER OF 8" WALL & WITH #4 HORIZONTAL REINFORCING AT 0'-8" ON CENTER.
= SLAB DEPRESSION; SEE PLAN FOR DEPRESSION EXTENTS AND DEPRESSION DEPTH AT DOCK
LEVELER.
&X'&X"
7" MINIMUM THICKNESS SLAB-ON-GRADE REINFORCED WITH #4 BARS @ 8" O.C. BOTTOM BARS EACH WAY WITH 2" CLR. TO BOT. 7" SLABS WILL REQUIRE DOWELLED JOINTS, WHICH WILL REQUIRE (2) POURS7" SLAB =
4" MINIMUM THICKNESS SLAB-ON-GRADE REINFORCED WITH WWF 6x6 W2.0xW2.0 WITH 2" CLR.
POSITIVE SUPPORT FROM BOTTOM OF SLAB.
4" SLAB =
(2) #4x4'-0" RE-ENTRANT CRACK CONTROL REINF. W/ 1-1/2"
CLR TO TOP OF SLAB
= VERTICAL CONCRETE WALL CONTROL JOINT LOCATION (15 FT MAXIMUM SPACING); SEE TYPICAL DETAILS ON S&7
AS�BUILT
96 CEG, OFFICE FORM 002, FY2018
DATEREVISION BY APPR'D
PROGRAM MANAGER
ENVIROMENTAL
INDEX NO.
CENM
APPROVED
APPROVED
APPROVED
SIGNATURE
DATE
USING AGENCY
APPROVED
APPROVED
COMMUNICATIONS
OPERATIONS ENGINEERING
APPROVED
APPROVED
APPROVED
APPROVED
FIRE PREVENTION
SAFETY REPRESENTATIVE
DIR. BASE MED. SERVICE
PROJ. ENGR.
DRAWN BY TITLE
CONTENTS
APPROVED
SCALE
DATE
96 CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
SPEC. NO. PROJ. NO. DRAWING NO. FILE NO.
SHEET OFFTFA
DESCRIPTION
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
APPROVED
D
EU
SOJ
R E
G
ISTERE
R E
E
NIGNED
EPH
ER
IL
SI
U
OL
A
DIOL
F R
STATE OF
No. 54319
E T
ACFIT
C R
E
I
301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501
JOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLC S T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SJDA
STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA
P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515
JULY,2019
J. SUMRALL
L. DeREUIL
Hernandez Calhoun Design International Architecture ● Interior Design
RENOVATE
BUILDING 886
EGLIN, AFB,FLORIDA
17�1100 XXXX17AP
Hernandez Calhoun Design International Architecture ● Interior Design 17AP
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199
7/12/20197/12/20197/12/20197/12/2019
S-3
ENLARGED PLANS - BASE BID
1/4" = 1'-0"S-3
1 BASE BID - NORTH STAIR PAD
1/4" = 1'-0"S-3
2 BASE BID - NORTH STAIR PAD
1/4" = 1'-0"S-3
3 BASE BID - NORTH LOADING DOCK
1/4" = 1'-0"S-3
4 BASE BID - SOUTH RAMP
1/4" = 1'-0"S-3
5 BASE BID - LOADING DOCK
SHEET NOTE: COORDINATE TOP OF SLAB ELEVATIONS WITH ARCHITECTURAL DRAWINGS.
C D E F G H I J K L
8" SLAB 8" SLAB
/4
/4
/4
C .J
C .J
C .J
C .J
C .J
C .J
C .J
C .J
15' & 0" 15' & 0" 15' & 0" 15' & 0" 15' & 0" 15' & 0" 15' & 0" 15' & 0" 13' & 8"
S-5
S-5
LEGEND
= CONSTRUCTION JOINT; PLACE C.J. AT 15'-0" O.C. MAXIMUM SPACING. CUT 50% OF REINF. AT
JOINTS. PROVIDE VERTICAL WALL JOINTS AT HORIZONTAL JOINT LOCATIONS, TYPICAL.
C.J.
= 8" CONCRETE WALL. WALL SHALL BE REINFORCED WITH #4 VERTICAL REINFORCING AT 1'-0" ON
CENTER IN CENTER OF 8" WALL & WITH #4 HORIZONTAL REINFORCING AT 0'-8" ON CENTER.
= SLAB DEPRESSION; SEE PLAN FOR DEPRESSION EXTENTS AND DEPRESSION DEPTH AT DOCK
LEVELER.
&X'&X"
7" MINIMUM THICKNESS SLAB-ON-GRADE REINFORCED WITH #4 BARS @ 8" O.C. BOTTOM BARS EACH WAY WITH 2" CLR. TO BOT. 7" SLABS WILL REQUIRE DOWELLED JOINTS, WHICH WILL REQUIRE (2) POURS7" SLAB =
4" MINIMUM THICKNESS SLAB-ON-GRADE REINFORCED WITH WWF 6x6 W2.0xW2.0 WITH 2" CLR.
POSITIVE SUPPORT FROM BOTTOM OF SLAB.
4" SLAB =
(2) #4x4'-0" RE-ENTRANT CRACK CONTROL REINF. W/ 1-1/2"
CLR TO TOP OF SLAB
= VERTICAL CONCRETE WALL CONTROL JOINT LOCATION (15 FT MAXIMUM SPACING); SEE TYPICAL DETAILS ON S&7
AS�BUILT
96 CEG, OFFICE FORM 002, FY2018
DATEREVISION BY APPR'D
PROGRAM MANAGER
ENVIROMENTAL
INDEX NO.
CENM
APPROVED
APPROVED
APPROVED
SIGNATURE
DATE
USING AGENCY
APPROVED
APPROVED
COMMUNICATIONS
OPERATIONS ENGINEERING
APPROVED
APPROVED
APPROVED
APPROVED
FIRE PREVENTION
SAFETY REPRESENTATIVE
DIR. BASE MED. SERVICE
PROJ. ENGR.
DRAWN BY TITLE
CONTENTS
APPROVED
SCALE
DATE
96 CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
SPEC. NO. PROJ. NO. DRAWING NO. FILE NO.
SHEET OFFTFA
DESCRIPTION
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
APPROVED
D
EU
SOJ
R E
G
ISTERE
R E
E
NIGNED
EPH
ER
IL
SI
U
OL
A
DIOL
F R
STATE OF
No. 54319
E T
ACFIT
C R
E
I
301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501
JOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLC S T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SJDA
STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA
P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515
JULY,2019
J. SUMRALL
L. DeREUIL
Hernandez Calhoun Design International Architecture ● Interior Design
RENOVATE
BUILDING 886
EGLIN, AFB,FLORIDA
17�1100 XXXX17AP
Hernandez Calhoun Design International Architecture ● Interior Design 17AP
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199
7/12/20197/12/20197/12/20197/12/2019
S-4
ENLARGED PLANS - BID OPTION
1/4" = 1'-0"S-4
1 BID OPTION - SOUTH LOADING DOCK
SHEET NOTE: COORDINATE TOP OF SLAB ELEVATIONS WITH ARCHITECTURAL DRAWINGS.
EXISTING SLAB
7" SLAB
EXISTING FOUNDATIONS
EXISTING WALL
1/2" PREMOLDED
JOINT FILLER
REFER TO DETAIL ON 1/S&7
FOR TYPICAL DETAIL AT NEW
SLAB TO EXISTING SLAB
COMPACTED
SUBGRADE
EXISTING SLAB 7" SLAB (SEE PLAN
FOR REINFORCING)
EXISTING FOUNDATIONS
EXISTING WALL
REFER TO DETAIL 1/S&5
FOR CONCRETE REPAIR
IN EXISTING NOTCH
6" 8" 1'&6"
4" SLAB, (SEE PLAN
FOR REINFORCING)
8" CONCRETE WALL; (SEE
PLAN FOR REINFORCING)
REFER TO DETAIL ON 1/S&7
FOR TYPICAL DETAIL AT NEW
SLAB TO EXISTING SLAB
1' &0
PROVIDE 3/4" CHAMFER;
TYPICAL
PROVIDE RAILINGS TO
MEET THE REQUIREMENTS
OF THE IBC AND ARCHITECTURAL
DRAWINGS AND SPECIFICATIONS.
1/2" PREMOLDED
JOINT FILLER
COMPACTED
SOIL
4"
#4 EDGE BAR 1&1/2" CLR,
TYP. AT ALL EDGES
#3 @ 12" O.C.
24"
24"
8" M
IN
B A
S E
D O
N G
R A
D E
V A
R
IE
S
'&2
T O
'&1
0"
#4 @ 8" CONT.
#4 @ 12"
(6) # 4 CONT.
BARS
GEOFOAM EPS 22 FILL
(OR EQUIVALENT)
COMPACTED
SUBGRADE
MEMBRANE TO PROTECT
FORM FROM PETROLEUM
PRODUCTS
I
7" SLAB (SEE PLAN
FOR REINFORCING)
6" 8" 1'&6"
7" SLAB, (SEE PLAN
FOR REINFORCING)
8" CONCRETE WALL; (SEE
PLAN FOR REINFORCING)
1' &0
"1/2" PREMOLDED
JOINT FILLER
GALV L3x3x1/4 W/ 1/2" DIA. x 6" HS @ 12" O.C.
#3 @ 12" O.C.
24"
24"
PROVIDE 3/4" CHAMFER;
TYPICAL
WEEP HOLES @ WALL
CONTROL JOINTS. #4 @ 8" CONT.
#4 @ 12"
(6) # 4 CONT.
BARS
GEOFOAM EPS 22 FILL
(OR EQUIVALENT)
MEMBRANE TO PROTECT
FORM FROM PETROLEUM
PRODUCTS
COMPACTED
SUBGRADE
6" 8" 1'&6"
7" SLAB, (SEE PLAN
FOR REINFORCING)
8" CONCRETE WALL;
(SEE PLAN FOR
REINFORCING)
1' &0
GALV L3x3x1/4 W/ 1/2" DIA. x 6" HS @ 12" O.C.
#3 @ 12" O.C.
24"
PROVIDE 3/4" CHAMFER;
TYPICAL
24"
EXISTING FOUNDATIONS
EXISTING WALL
REMOVE CRACKED CONCRETE
FROM NOTCH SEE PHOTO, CUT
CLEAN EDGE & PROVIDE 1/2"
RADIUS EDGE AT DOOR.
WHERE APPLICABLE, REPAIR SPALLED
CONCRETE W/ HORIZONTAL CUT, BONDING
AGENT & PATCHING MORTAR. ASSUME 20
LINEAR FT. FOR BIDDING PURPOSES.
BOND BREAKER
(LAYER OF 30# FELT)
1/2" PREMOLDED
JOINT FILLER
B A
S E
D O
N G
R A
D E
V A
R
IE
S
'&2
T O
'&1
0"
FIN. FLOOR1/
2"
S T
E P
#4 @ 8" CONT.
#4 @ 12"
(6) # 4 CONT.
BARS
GEOFOAM EPS 22
FILL (OR
EQUIVALENT)
MEMBRANE TO PROTECT
FORM FROM PETROLEUM
PRODUCTS
COMPACTED
SUBGRADE
EXISTING SLAB
REFER TO DETAIL ON
1/S&7 FOR TYPICAL
DETAIL AT NEW SLAB
TO EXISTING SLAB
1/2" P.J.F.
EXISTING WALL
REMOVE CRACKED CONCRETE
FROM NOTCH SEE PHOTO, CUT
CLEAN EDGE & PROVIDE 1/2"
RADIUS EDGE AT DOOR.
BOND BREAKER
(LAYER OF 30# FELT)
REPAIR SPALLED CONCRETE W/
HORIZONTAL CUT, BONDING
AGENT & PATCHING MORTAR.
1/2" PREMOLDED
JOINT FILLER
7" SLAB, (SEE PLAN
FOR REINFORCING)
GEOFOAM EPS
22 FILL (OR
EQUIVALENT)
MEMBRANE TO
PROTECT FORM FROM
PETROLEUM PRODUCTS
AS�BUILT
96 CEG, OFFICE FORM 002, FY2018
DATEREVISION BY APPR'D
PROGRAM MANAGER
ENVIROMENTAL
INDEX NO.
CENM
APPROVED
APPROVED
APPROVED
SIGNATURE
DATE
USING AGENCY
APPROVED
APPROVED
COMMUNICATIONS
OPERATIONS ENGINEERING
APPROVED
APPROVED
APPROVED
APPROVED
FIRE PREVENTION
SAFETY REPRESENTATIVE
DIR. BASE MED. SERVICE
PROJ. ENGR.
DRAWN BY TITLE
CONTENTS
APPROVED
SCALE
DATE
96 CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
SPEC. NO. PROJ. NO. DRAWING NO. FILE NO.
SHEET OFFTFA
DESCRIPTION
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
APPROVED
D
EU
SOJ
R E
G
ISTERE
R E
E
NIGNED
EPH
ER
IL
SI
U
OL
A
DIOL
F R
STATE OF
No. 54319
E T
ACFIT
C R
E
I
301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501
JOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLC S T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SJDA
STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA
P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515
JULY,2019
J. SUMRALL
L. DeREUIL
Hernandez Calhoun Design International Architecture ● Interior Design
RENOVATE
BUILDING 886
EGLIN, AFB,FLORIDA
17�1100 XXXX17AP
Hernandez Calhoun Design International Architecture ● Interior Design 17AP
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199
7/12/20197/12/20197/12/20197/12/2019
S-5
SECTIONS AND DETAILS
3/4" = 1'-0"S-5
2 NEW SLAB ON GRADE DETAIL
3/4" = 1'-0"S-5
4 CONCRETE WALL AT STAIR
3/4" = 1'-0"S-5
5 LOADING BAY SECTION
3/4" = 1'-0"S-5
1 TYPICAL LOADING DOCK SECTION
IMAGE AT EXISTING DOOR
3/4" = 1'-0"S-5
3 LOADING BAY SECTION
PROVIDE 3/4" CHAMFER;
TYPICAL
PROVIDE RAILINGS TO
MEET THE REQUIREMENTS
OF THE IBC AND ARCHITECTURAL
DRAWINGS AND SPECIFICATIONS.
4" SLAB&ON&GRADE
RAMP; TYPICAL
#4 CONT.;
TYPICAL
CENTERLINE OF
RAILINGS
CENTERLINE OF RAILING
SLAB EDGE
SLAB EDGE
EXISTING
FOUNDATIONS
EXISTING WALL
4" SLAB&ON&GRADE
RAMP; TYPICAL
4"
4"4"
4'-6"FIN. FLOOR1/
2"
S T
E P
EXISTING
SLAB
REPLACE DEMOLISHED
PAVEMENT
COMPACTED
SUBGRADE COMPACTED
FILL
LINE OF
EXCAVATION
8" M
IN
#3 @ 12" O.C.
24"
24"
#3 @ 12" O.C.
24"
24"
REFER TO DETAIL 1/S&5
FOR CONCRETE REPAIR
IN EXISTING NOTCH
#4 @ 8" CONT.
#4 @ 12"
(6) # 4 CONT.
BARS
#4 @ 8" CONT.
#4 @ 12"
(5) # 4 CONT.
BARS
#4 @ 8" CONT.
#4 @ 12"
(4) # 4 CONT.
BARS
CENTER ALL WALL
REINFORCING IN FOOTER
1/2" P.J.F.
(TYP.)
1'&0" 8" 1'&0"8" 8" 8"5" 8" 5"
GEOFOAM EPS 22 FILL
(OR EQUIVALENT)
MEMBRANE TO PROTECT
FORM FROM PETROLEUM
PRODUCTS
4' & 0" 4' & 0" 5' & 6"
1/2" P.J.F.
GEOFOAM
FILL
GALV L3x3x1/4 W/ 1/2" DIA. x 6" HS @ 12" O.C.
7" SLAB (SEE PLAN
FOR REINFORCING)
#3 @ 12" O.C.16"
16"
7" SLAB (SEE PLAN
FOR REINFORCING)
PROVIDE 3/4"
CHAMFER; TYPICAL
S-6
6'&0"
OPTIONAL COLD
JOINT
GEOFOAM
FILL
I
S-6
GALV L3x3x1/4 W/ 1/2" DIA. x 6" HS @ 12" O.C.
7" SLAB (SEE PLAN
FOR REINFORCING)
#3 @ 12" O.C. 16"
16"
7" SLAB (SEE PLAN
FOR REINFORCING)
PROVIDE 3/4"
CHAMFER; TYPICAL
GALV L3x3x1/4 W/ 1/2" DIA. x 6" HS @ 12" O.C.
#3 @ 12" O.C.24"
24"
1' &7" + /& 1 /8 "
1' &8
1/
8"
DOCK LEVELER
WALL BEYOND
7" SLAB (SEE PLAN
FOR REINFORCING)
EXISTING SLAB
REFER TO DETAIL ON 1/S&6
FOR TYPICAL DETAIL AT NEW
SLAB TO EXISTING SLAB
6" 8" 1'&6"
#4 @ 8" CONT.
#4 @ 12"
(6) # 4 CONT.
BARS
8'&0"
PROVIDE MITERED
CORNER PIECES (TYP.)
COMPACTED FILL
GEOFOAM EPS 22 FILL
(OR EQUIVALENT)
MEMBRANE TO PROTECT
FORM FROM PETROLEUM
PRODUCTS
1/2" P.J.F.
7" SLAB, (SEE PLAN
FOR REINFORCING)
8" CONCRETE WALL; (SEE
PLAN FOR REINFORCING)
GALV L3x3x1/4 W/ 1/2" DIA. x 6"
HS @ 12" O.C. AT LOADING
DOCK LOCATIONS
#3 @ 12" O.C.
24"
24"
PROVIDE 3/4" CHAMFER;
TYPICAL
GEOFOAM EPS 22 FILL
(OR EQUIVALENT)
#4 @ 6" O.C.
18"
(3) #4 TIES
PROVIDE SLEEVE PER CANOPY DESIGNER'S
RECOMMENDATIONS. EMBED COLUMN INTO
CONCRETE PER CANOPY DESIGNER'S
RECOMMENDATIONS.
PRE&ENGINEERED ALUMINUM
COLUMN; BY CANOPY DESIGNER
8" 1' & 2" 5"
10"
18"
1' &2
6"
#4 @ 8" CONT.
PROVIDE SLEEVE PER CANOPY DESIGNER'S
RECOMMENDATIONS. EMBED COLUMN INTO
CONCRETE PER CANOPY DESIGNER'S
RECOMMENDATIONS.
PRE&ENGINEERED
ALUMINUM COLUMN; BY
CANOPY DESIGNER
5'&6"
(5) #5 BARS EACH
WAY, TOP & BOTTOM
2'&0"
A A
SECTION AA
(8) #5 VERTICAL
BARS
#3 TIES @ 12" O.C.
5'&6" x 5'&6" x 12"
THICK FOOTER
C O
V E
R
M
IN
.1 8"
#4 @ 6" O.C.
18"
16"
18"
2'&0"
7" 10" 7"
5" 1'&2" 5"
1' &2
2'
&1 0"
3/4" CHAMFER;
TYP.
(3) #4
ADDITIONAL
TIES
3/4" CHAMFER;
TYP.
4' &4
1'&9" 2'&0" 1'&9"
3" M
IN
TO TIES
2" TYP.
AS�BUILT
96 CEG, OFFICE FORM 002, FY2018
DATEREVISION BY APPR'D
PROGRAM MANAGER
ENVIROMENTAL
INDEX NO.
CENM
APPROVED
APPROVED
APPROVED
SIGNATURE
DATE
USING AGENCY
APPROVED
APPROVED
COMMUNICATIONS
OPERATIONS ENGINEERING
APPROVED
APPROVED
APPROVED
APPROVED
FIRE PREVENTION
SAFETY REPRESENTATIVE
DIR. BASE MED. SERVICE
PROJ. ENGR.
DRAWN BY TITLE
CONTENTS
APPROVED
SCALE
DATE
96 CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
SPEC. NO. PROJ. NO. DRAWING NO. FILE NO.
SHEET OFFTFA
DESCRIPTION
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
APPROVED
D
EU
SOJ
R E
G
ISTERE
R E
E
NIGNED
EPH
ER
IL
SI
U
OL
A
DIOL
F R
STATE OF
No. 54319
E T
ACFIT
C R
E
I
301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501
JOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLC S T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SJDA
STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA
P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515
JULY,2019
J. SUMRALL
L. DeREUIL
Hernandez Calhoun Design International Architecture ● Interior Design
RENOVATE
BUILDING 886
EGLIN, AFB,FLORIDA
17�1100 XXXX17AP
Hernandez Calhoun Design International Architecture ● Interior Design 17AP
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199
7/12/20197/12/20197/12/20197/12/2019
S-6
SECTIONS AND DETAILS
3/4" = 1'-0"S-6
2 CONCRETE RAMP SECTION
3/4" = 1'-0"S-6
1 DOCK LEVELER SECTION
3/4" = 1'-0"S-6
3 DOCK LEVELER SECTION
3/4" = 1'-0"S-6
4 TYPICAL ALUMINUM CANOPY COLUMN SLEEVE
3/4" = 1'-0"S-6
5 TYPICAL ALUMINUM CANOPY COLUMN
6"
1'&6 O.C.
2" C
LR
7"
3"
CLR.
1 2 T
1 2 T
P
N A
C o n s tr u c tio n T e c h n o lo g ie s , I n c
. A ll ri g h ts r e s e rv e d . D ia m o n d D o w e l®
, A rm o r-
E d g e
, L o a d P la te
B a s k e t® a n d P
D
B a s k e t® a re r e g is te re d tr a d e m a rk s a n d
H y d ra
C u re a n d S q u a re
D o w e l C lip a re tr a d e m a rk s o f P N
A C o n s tr u c tio n
T e c h n o lo g ie s
, I n c . P ro d u c ts s h o w n m a y b e c o v e re d b y o n e o r m o re o f U .S
. p a te n ts
,7
,9
,3
,7
; G re a t B ri ta in p a te n t #
; M e x ic o p a te n t #
; N e w
Z e a la n d p a te n t #
; I n d ia p a te n t # a n d o th e r p e n d in g p a te n ts
SLOTS CUT USING COVEX
CV&9000 SAW FOR PLATES UP
TO 3/4" (20 MM) TO ENSURE
SAFE AND ACCURATE
INSTALLATION IN THE FIELD.
EXISTING SLAB
COVEX 3/8" DOWELS MANUFACTURED
FROM HOT&ROLLED STEEL CERTIFIED TO
MEET ASTM A36, CUT FULL&DEPTH AND
DEBURRED PER INDUSTRY GUIDELINES.
COVES DOWEL SYSTEM AS
MANUFACTURED BY PNA CONSTRUCTION
TECHNOLOGIES, INC. MARSHA MOORE
HARDING / SE TERRITORY MANAGER /
PNA / 678&576&1223.
SELECT OPTION BASED
ON AVAILABILITY OF
SAW AND DOWELS
OPTION 1
COVEX DOWEL
SPACED AS INDICATED
EXISTING SLAB
APPLY BOND BREAK
AGENT TO EXISTING SLAB
NEW SLAB
REINF. (SEE PLAN)
OPTION 2
2" C
LR
7"
3"
CLR.
7/8" Ø x 14" LONG SMOOTH
DOWEL @ 12" O.C.
EXISTING SLAB
APPLY BOND BREAK
AGENT TO EXISTING SLAB
NEW SLAB
REINF. (SEE PLAN)
E Q
E Q
DRILL & EPOXY
COAT TO
PREVENT BOND
1/2" x 1&1/2" PLASTIC OR
HARDBOARD PREFORMED STRIP
FIRST SLAB
PLACEMENT
SECOND SLAB
PLACEMENT
DIAMOND
DOWEL SYSTEM
1' &6
1'
&6
2" C
LR
8"
3"
CLR.
REINF.(SEE PLAN)
APPLY BOND BREAK
AGENT TO FIRST SLAB
REINF. (SEE PLAN)
3/4" x 4 1/2" SQUARE DIAMOND DOWEL
SYSTEM AS MANUFACTURED BY PNA
CONSTRUCTION TECHNOLOGIES, INC.
MARSHA MOORE HARDING / SE
TERRITORY MANAGER / PNA /
678&576&1223.
3/4" CHAMFER EACH FACE
CUT OR TERMINATE 50% OF
HORIZONTAL REINF. AT JOINT
CRACK INDUCED BY
CONTROL JOINT
3/4" CHAMFER EACH FACE
CUT OR TERMINATE 50% OF
HORIZONTAL REINF. AT JOINT
CRACK INDUCED BY
CONTROL JOINT
TYPICAL WALL CONTROL JOINT DETAIL
TYPICAL WALL CONSTRUCTION JOINT DETAIL
TYPICAL WALL REINF.
TYPICAL WALL REINF.
2" CLR. TYP.
2" CLR. TYP.
SINGLE LAYER OF REINF.
AS�BUILT
96 CEG, OFFICE FORM 002, FY2018
DATEREVISION BY APPR'D
PROGRAM MANAGER
ENVIROMENTAL
INDEX NO.
CENM
APPROVED
APPROVED
APPROVED
SIGNATURE
DATE
USING AGENCY
APPROVED
APPROVED
COMMUNICATIONS
OPERATIONS ENGINEERING
APPROVED
APPROVED
APPROVED
APPROVED
FIRE PREVENTION
SAFETY REPRESENTATIVE
DIR. BASE MED. SERVICE
PROJ. ENGR.
DRAWN BY TITLE
CONTENTS
APPROVED
SCALE
DATE
96 CEG/CEN
APPROVED
DEPUTY BASE CIVIL ENGINEER
SPEC. NO. PROJ. NO. DRAWING NO. FILE NO.
SHEET OFFTFA
DESCRIPTION
SECURITY FORCES
APPROVED
ASUS
APPROVED
CHELCO
APPROVED
D
EU
SOJ
R E
G
ISTERE
R E
E
NIGNED
EPH
ER
IL
SI
U
OL
A
DIOL
F R
STATE OF
No. 54319
E T
ACFIT
C R
E
I
301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951301 West Cervantes St. Tel. 850.429.1951 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501 Pensacola, FL 32501
JOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLCJOE DEREUIL ASSOCIATES, LLC S T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SS T R U C T U R A L E N G I N E E R SJDA
STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA STATE OF FLORIDA
P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515P.E. NO. 54319 / C.A. NO. 9515
JULY,2019
J. SUMRALL
L. DeREUIL
Hernandez Calhoun Design International Architecture ● Interior Design
RENOVATE
BUILDING 886
EGLIN, AFB,FLORIDA
17�1100 XXXX17AP
Hernandez Calhoun Design International Architecture ● Interior Design 17AP
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199JDA Job #: 17199
7/12/20197/12/20197/12/20197/12/2019
S-7
TYPICAL DETAILS
3/4" = 1'-0"S-7
1 TYPICAL DETAIL AT NEW SLABS TO EXISTING SLABS
3/4" = 1'-0"S-7
2 TYPICAL CONSTRUCTION JOINT DETAIL
3/4" = 1'-0"S-7
3 TYPICAL VERTICAL WALL CONTROL JONT DETAILS
07/27/2018
Door Schedule
Mark Space
Door Frame Hardware
Remarks
Size Door Material
Door Type Glazing
Frame Material
Frame Type
Details Set Number
Keyside SpaceWidth Height Thick. Head Jamb Sill
Window/Louver Schedule
Mark
Window/Louver Frame
Remarks
Size Glazing Type Material
Details
Width Height Head Jamb Sill
BASE CIVIL ENGINEER
ROOM FINISH SCHEDULE
ROOM
No. ROOM NAME
FLOOR BASE WALLS CEILING
REMARKS
MATERIAL COLOR MATERIAL COLOR
NORTH EAST SOUTH WEST
MATERIAL COLOR
MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR MATERIAL COLOR
SIGNAGE SCHEDULE
# TYPE SIGN
SIZE
TEXT/
DESCRIPTION NOTES
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
AS-BUILT
RENOVATIONS TO
BUILDING 886
EGLIN AFB, FLORIDA
FACU
DISPLAY
MONACO
TRANSMISSION
SUPERVISING
STATION (SS)
EVAC
AU
D
IO
/V
IS
U
AL
T
R O
U
BL
E
IN
D
IC
AT
IO
N B
Y D
EV
IC
E
XM
IT
A
LA
R M
S
IG
N
AL
PU
LL
ST
AT
IO
N T
O S
S
XM
IT
T R
O U
BL
E
SI
G
N
AL
T O
S S
FI
R
E
AL
AR
M
S
TR
O
BE
S
TH
R O
U G
H O
U T
G
EN
. E
VA
C M
ES
SA
G E
TH
R
O U
G H
O U
T
MANUAL PULL STATION X
FIRE ALARM AC POWER FAILURE
FIRE ALARM SYSTEM LOW/MISSING BATTERY
ALARM SIGNALS
TROUBLE SIGNALS
SHORT CIRCUIT
OPEN CIRCUIT
GROUND FAULT
AU
D
IO
/V
IS
U
AL
A
LA
R
M
IN
D
IC
AT
IO
N B
Y D
EV
IC
E
X XX
X X X X X
X X X X X
XM
IT
A
LA
R M
S
IG
N
AL
W
AT
ER
FL
O
W T
O S
S
XM
IT
A
LA
R M
S
IG
N
AL
-S M
O
KE
D
ET
EC
TO
R T
O S
S
SUPERVISED COMPONENT FAILURE
SUPERVISING STATION CONNECTION FAULT
X X
X
X X XXSMOKE DETECTOR - FACP
SPRINKLER SYSTEM WATERFLOW SWITCH X X X X
CARBON MONOXIDE DETECTOR X
XM
IT
A
LA
R M
S
IG
N
AL
C
AR
BO
N M
O N
O
XI
D E
TO
S
S
X XX
SUPERVISORY SIGNALS
SPRINKLER SYSTEM TAMPER SWITCH
XM
IT
T
AM
PE
R
S W
IT
C
H
SU
PE
R
VI
SO
R Y
S
IG
N
AL
T O
S S
AU
D
IO
/V
IS
U
AL
S
U
PE
R
VI
SO
R
Y
IN
D
IC
AT
IO
N B
Y D
EV
IC
E
X X
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
AS-BUILT
RENOVATIONS TO
AS-BUILT
RENOVATIONS TO
D P R O J E C T
R e n o v a t e
B u i l d i n g
D W G M e c h M d w g
P M j o i n e r
D P R O J E C T
R e n o v a t e
B u i l d i n g
D W G P l u m b i n g P d w g
P M j o i n e r
AS-BUILT
RENOVATIONS TO
AS-BUILT
RENOVATIONS TO
AS-BUILT
RENOVATIONS TO
AS-BUILT
RENOVATIONS TO
AS-BUILT
RENOVATIONS TO
AS-BUILT
RENOVATIONS TO
AS-BUILT
RENOVATIONS TO
AS-BUILT
RENOVATIONS TO
TELECOMMUNICATIONS & ELECTRONIC SECURITY SYSTEM LEGEND
DEVICE
SYMBOL
SYMBOL
SUBSCRIPT -
TYPE 'x'
DESCRIPTION CAT 6 UTP (QTY) RG-6 COAX
(QTY)
FIBER MODULE
(DUPLEX QTY)
JACK/MODULE
TYPE
JACK/MODULE
COLOR
MOUNTING HEIGHT AFF
(UNO)
BUILDING SUPPORT SYSTEM DEVICES
DDC DIRECT DIGITAL CONTROLS NETWORK OUTLET (2) - - RJ-45 VIOLET 48"; COORD. W/ VENDOR;
SEE DETAIL
UNCLASSIFIED NETWORK DEVICES
- NIPRNET/VOICE OUTLET (2) - - RJ-45 WHITE 18"; SEE DETAIL
UNCLASSIFIED WALL MOUNT VOICE DEVICES
- WALL MOUNT VOICE OUTLET (1) - - RJ-45 WHITE 48"
UNCLASSIFIED RACEWAY & SUPPORTING INFRASTRUCTURE
- ABOVEGROUND CONDUIT - - - - - SEE PLAN
PBB PRIMARY BONDING BUSBAR - - - - - SEE PLAN; DETAILS
UNCLASSIFIED RACEWAY & SUPPORTING INFRASTRUCTURE - SITE
- UNDERGROUND CONDUIT - - - - - SEE PLAN
AUDIO VISUAL SYSTEMS - ROUGH-IN ONLY
- FLAT PANEL DISPLAY ROUGH-IN - (1) - F-CONN MATCH
FACEPLATE SEE DETAILS
- AV ROUGH-IN - - - - - SEE DETAILS
ACCESS CONTROL SYSTEM (ACS)
- CARD READER - INTERIOR SEE ACS DIAGRAM 48"; SEE DETAILS
EXT CARD READER - EXTERIOR SEE ACS DIAGRAM 48"; SEE DETAILS
- ACS INTERFACE UNIT SEE ACS DIAGRAM SEE PLAN
x
ABOVE FINISH FLOOR
ACCREDITING OFFICIAL
AMERICANS WITH DISABILITIES ACT
AMERICAN NATIONAL STANDARDS INSTITUTE
AMERICAN WIRE GAUGE
APPROVING AUTHORITY
ARCHITECTURAL
AUTHORITY HAVING JURISDICTION
BONDING BACKBONE CONDUCTOR
BUILDING AUTOMATION SYSTEM
CABLE TRAY
CATEGORY 3
CATEGORY 5 ENHANCED
CATEGORY 6
CATEGORY 6 AUGMENTED
COMMUNICATIONS OUTLET
COMMUNITY ANTENNA TELEVISION
CONDUIT
CONSOLIDATION POINT
CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CONTRACTOR FURNISHED, GOVERNMENT INSTALLED
CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE
DEMARCATION
ELECTRICAL
ELECTROMAGNETIC INTERFERENCE
ENERGY MANAGEMENT CONTROL SYSTEM
ELECTRICAL METALLIC TUBING
FEDERAL COMMUNICATIONS COMMISSION
FIBER OPTIC
GOVERNMENT FURNISHED, CONTRACTOR INSTALLED
GOVERNMENT FURNISHED, GOVERNMENT INSTALLED
HANDHOLE
LOCAL AREA NETWORK
LIGHT INTERCONNECT UNIT
MAIN TELECOMMUNICATIONS ROOM
MAINTENANCE HOLE
MAXIMUM
MICRON / MICROMETER
MINIMUM
MULTI-USER TELECOMMUNICATIONS OUTLET ASSEMBLY
MULTIMODE
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL SAFETY CODE
NATIONAL FIRE PROTECTION ASSOCIATION
UNCLASSIFIED INTERNET PROTOCOL ROUTER NETWORK
NOT APPLICABLE
NOT IN CONTRACT
OUTSIDE PLANT
PAIR
PATCH PANEL
POLYVINYL CHLORIDE
PULL BOX
PRIMARY BONDING BUSBAR
PRIVATE BRANCH EXCHANGE
RACK MOUNTED UNIT
ROOM
ROUGH-IN
SCREENED TWISTED-PAIR
SECONDARY BONDING BUSBAR
SECURED VIDEO TELECONFERENCE
SHIELDED TWISTED-PAIR
SINGLEMODE
SURFACE MOUNT
STRANDS
TELECOMMUNICATIONS BONDING BACKBONE
TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR
TELECOMMUNICATIONS BONDING CONDUCTOR
TELECOMMUNICATIONS EQUIPMENT ROOM
TELECOMMUNICATIONS ROOM
TELECOMMUNICATIONS INDUSTRY ASSOCIATION
UNDERWRITERS LABORATORIES INC
UNINTERRUPTIBLE POWER SUPPLY
UNSHIELDED TWISTED-PAIR
TYPICAL
UNLESS NOTED OTHERWISE
VIDEO TELECONFERENCE
VOICE OVER INTERNET PROTOCOL
AFF
A.O.
ADA
ANSI
AWG
AA
ARCH
AHJ
BBC
BAS
CT
CAT 3
CAT 5E
CAT 6
CAT 6A
CO
CATV
C
CP
CFCI
CFGI
COTR
DEMARC
ELEC
EMI
EMCS
EMT
FCC
FO
GFCI
GFGI
HH
LAN
LIU
MTR
MH
MAX
um
MIN
MUTOA
MM
NEMA
NEC
NESC
NFPA
NIPRNET
N/A
NIC
OSP
PR
PP
PVC
PB
PBB
PBX
RMU
RM
R/I
ScTP
SBB
SVTC
STP
SM
SF
STR
TBB
TEBC
TBC
TER
TR
TIA
UL
UPS
UTP
TYP
UNO
VTC
VoIP
TELECOM ABBREVIATIONS:
FP
CR
ACS
x
AV
BASE CIVIL ENGINEER
EGLIN AIR FORCE BASE, FLORIDA
AS-BUILT
RENOVATIONS TO
BUILDING 886
EGLIN AFB, FLORIDA
TELECOM & SECURITY LEGEND & ABBREVIATIONS
T001
TELECOMMUNICATIONS GENERAL NOTES - FACILITY INFRASTRUCTURE:
THE TELECOMMUNICATIONS DRAWINGS PROVIDED ARE DIAGRAMMATIC AND SHOW THE GENERAL
LOCATION OF ALL REQUIRED DEVICES; SUCH AS OUTLETS, RACEWAYS, EQUIPMENT, AND
APPURTENANCES. THEY DO NOT SHOW ALL NECESSARY OFFSETS, JUNCTION BOXES,
CABLE/LADDER TRAY TRANSITIONS, CONDUIT SLEEVES/PENETRATIONS, AND ADJUSTMENTS
NECESSARY BY COORDINATION WITH OTHER TRADES IN THE FIELD.
TELECOMMUNICATION CONTRACTOR'S SCOPE OF WORK: TELECOMMUNICATION'S CONTRACTOR
SHALL BE RESPONSIBLE FOR ENTIRE STRUCTURED CABLING SYSTEM ELEMENTS DEFINED IN THIS SCOPE OF WORK. THIS INCLUDES A COMPLETE INSTALLATION OF ALL PASSIVE INFRASTRUCTURE ELEMENTS SUCH AS OUTLETS, JACKS, CABLING, CABINETS, BACKBOARDS, TELECOM EQUIPMENT ROOM/CABINET BONDING, TERMINATIONS, TESTING, LABELING, WARRANTIES, AND ALL REQUIRED
CLOSE-OUT DOCUMENTS. THE TELECOMMUNICATIONS CONTRACTOR SHALL UNDERSTAND THE
FULL INTENT OF THE DRAWINGS AND SPECIFICATIONS PRIOR TO BID, AND WILL INCLUDE IN SCOPE
OF WORK ALL REQUIREMENTS NECESSARY TO ENSURE A FULLY FUNCTIONAL SYSTEM.
COORDINATION: WITH OTHER TRADES EXAMINE AND REVIEW THE DOCUMENTS OF ALL DIVISIONS IN ORDER TO COORDINATE THE INSTALLATION OF WORK. USE DIMENSIONED DRAWINGS TO VERIFY
THE SPACE NECESSARY FOR LOCATING OUTLETS, RACEWAYS, AND EQUIPMENT. USE FIELD
MEASUREMENTS TO VERIFY DIMENSIONS WHERE AREAS ARE CONGESTED, AND EXACT LOCATION
IS CRITICAL TO ENSURE PROPER INSTALLATION. COORDINATION SHALL INCLUDE, BUT NOT BE LIMITED TO; VERIFYING THE LOCATION AND SIZE OF OPENINGS/PENETRATIONS IN FLOORS, WALLS, PARTITIONS, CEILINGS, AND ROOFS WITH THE INSTALLING TRADES; ALLOCATION OF SPACE WITH OTHER TRADES, INSTALLING WORK IN CHASES, SHAFTS, CEILING INTERSTITIAL SPACES, AND EQUIPMENT SPACES; AND THE PHASING OF INSTALLATION WORK WITH THAT OF OTHER TRADES.
INSTALLATION SHALL CONFORM WITH NFPA 70 "NATIONAL ELECTRICAL CODE," ANSI/TIA, UFC 3-580-01, UFC 4-010-06, AND EGLIN AFB WIRE/CABLE SPECS - 96 CS DATED 11 AUG 2014 (UNO).
CABLING INSTALLATION: ALL CABLING ROUTED IN SLAB, BELOW VAPOR BARRIER OR BELOW
GRADE, SHALL BE U.L. LISTED FOR WET LOCATIONS THAT COMPLIES WITH UFC 3-580-01 AND NFPA
70. DO NOT USE PLENUM OR RISER RATED CABLE, GEL-FILLED OSP, AND UNLISTED CABLES IN SUCH
AN ENVIRONMENT.
USE A FILL RATIO OF 40 PERCENT FOR CONDUIT SIZING. DO NOT INSTALL MORE THAN FOUR, FOUR-PAIR CABLES IN A 1 INCH (27 MM) CONDUIT.
LABEL ALL CABLES WITHIN 4 INCHES OF EACH TERMINATION. PROVIDE 12 INCHES SERVICE LOOP AT
THE WORK AREA END OF EACH HORIZONTAL CABLE.
INSTALL VELCRO CABLE TIES TO ALL CABLE BUNDLES IN RACK WIRE MANAGEMENT, D-RINGS AND
OTHER SUPPORT MEANS.
BALANCED TWISTED-PAIR CABLING SHALL BE SEPARATED FROM FLUORESCENT LAMPS AND
ASSOCIATED FIXTURES BY A MINIMUM OF 5 IN.
THE MAXIMUM FILL OF ANY EXISTING CABLE TRAY SHALL NOT EXCEED 50%. THE MAXIMUM FILL
DEPTH OF ANY CABLE TRAY SHALL NOT EXCEED 6 IN.
TELECOMMUNICATIONS FACEPLATES SHALL MATCH ELECTRICAL SWITCH AND RECEPTACLE PLATE
FINISHES.
PROVIDE COVER PLATES FOR ALL UNUSED J-BOX LOCATIONS.
PROVIDE PULL STRING IN ALL EMPTY CONDUIT AND INNERDUCT. PULL STRING TO BE RATED FOR 200lbs. IN ALL CONDUIT.
MAIN TELECOM CABINET (MTC):
INSTALL BACKBOARDS IN ACCORDANCE WITH TIA-569-C. BACKBOARDS MUST BE FIRE-RETARDANT TREATED WOOD, BEARING THE MANUFACTURER’S STAMP. IF PAINTED, THE MANUFACTURES FIRE
RATED STAMP MUST REMAIN VISIBLE.
INSTALL WALL MOUNTED CABINETS MAINTAINING A MINIMUM OF 36 INCHES SPACE IN FRONT OF
CABINET. PROVIDE 25% SPARE CAPACITY WITHIN EACH UTILIZED RACK.
FURNITURE/MILLWORK:
ENSURE THAT THE CABLE IS PROTECTED AT ALL TRANSITION POINTS, AND THAT METALLIC
SEPARATION IS PROVIDED BETWEEN TELECOMMUNICATION AND POWER WIRING IN THE UTILITY
COLUMNS AND SYSTEMS FURNITURE TRACK IN ACCORDANCE WITH TIA-569-C AND NFPA 70.
ELECTRICAL GENERAL NOTES - FACILITY INFRASTRUCTURE:
ELECTRICAL CONTRACTOR'S SCOPE OF WORK:
ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE ENTIRE INTERIOR ROUGH-IN AND
SUPPORT SYSTEM NECESSARY FOR THE COMPLETE STRUCTURED CABLING SYSTEM DEFINED IN
THIS SCOPE OF WORK. THIS INCLUDES A COMPLETE INSTALLATION OF ALL REQUIRED PATHWAYS
INCLUDING: CONDUIT, BACK BOXES, JUNCTION BOXES, FLOOR BOXES, BLOCKING, GROUNDING
CONDUCTORS AND BUSBARS, FIRESTOPPING, POWER, AND ANY OTHER NECESSARY
APPURTENANCES.
THE ELECTRICAL CONTRACTOR SHALL UNDERSTAND THE FULL INTENT OF THE DRAWINGS AND
SPECIFICATIONS PRIOR TO BID, AND WILL INCLUDE IN SCOPE OF WORK ALL REQUIREMENTS
NECESSARY TO SUPPORT THE TELECOMMUNICATIONS SYSTEM TO COORDINATE AND ENSURE A
FULLY FUNCTIONAL SYSTEM.
COORDINATION WITH OTHER TRADES:
EXAMINE AND REVIEW THE DOCUMENTS OF ALL DIVISIONS IN ORDER TO COORDINATE THE
INSTALLATION OF WORK. USE DIMENSIONED DRAWINGS TO VERIFY THE SPACE NECESSARY FOR
LOCATING OUTLETS, RACEWAYS, AND EQUIPMENT. USE FIELD MEASUREMENTS TO VERIFY
DIMENSIONS WHERE AREAS ARE CONGESTED, AND EXACT LOCATION IS CRITICAL TO ENSURE
PROPER INSTALLATION. COORDINATION SHALL INCLUDE, BUT NOT BE LIMITED TO, VERIFYING THE LOCATION AND SIZE OF OPENINGS/PENETRATIONS IN FLOORS, WALLS, PARTITIONS, CEILINGS, AND ROOFS WITH THE INSTALLING TRADES; ALLOCATION OF SPACE WITH OTHER TRADES, INSTALLING WORK IN CHASES, SHAFTS, CEILING INTERSTITIAL SPACES, AND EQUIPMENT SPACES; AND THE
PHASING OF INSTALLATION WORK WITH THAT OF OTHER TRADES.
INSTALLATION SHALL CONFORM WITH NFPA 70 "NATIONAL ELECTRICAL CODE," ANSI/TIA, UFC 3-580-01, ELECTRICAL SPECIFICATIONS, AND EGLIN AFB WIRE/CABLE SPECS - 96 CS DATED 11 AUG 2014 (UNO).
CONDUIT:
INSTALL ELECTRICAL METALLIC TUBING (EMT) CONDUIT FROM THE CABLE BACKBONE…