08_-_UFGS_14_24_13.pdf

PDF 122 KB Posted

Attached to
Solicitation_GLEN_19-2013 Federal contract opportunity
Solicitation number
FA255019RA011
Issued by
Department of the Air Force Space Command

About this file

UFGS

View the file

Other files for this federal contract opportunity

Other files attached to Solicitation_GLEN_19-2013, newest first.
File Type Posted
Meeting_Minutes_MFR.pdf PDF
FA255019RA011_RFI_002_Answers.pdf PDF
DSC01723.JPG JPG image
DSC01719.JPG JPG image
DSC01728.JPG JPG image
DSC04184.JPG JPG image
DSC04176.JPG JPG image
DSC04721.JPG JPG image
DSC01752.JPG JPG image
DSC01737.JPG JPG image
DSC04714.JPG JPG image
DSC04718.JPG JPG image
DSC04717.JPG JPG image
DSC01720.JPG JPG image
DSC04725.JPG JPG image
01_-_ufc_3_600_01_2016_c2_Fire_Protection_Engineering_for_Facilities.pdf PDF
DSC04726.JPG JPG image
00_RFI_001_19-2013.pdf PDF
DSC01731.JPG JPG image
DSC04190.JPG JPG image
DSC04212.JPG JPG image
01-_ufc_3_490_06_2018_Elevators.pdf PDF
DSC01739.JPG JPG image
DSC04719.JPG JPG image
DSC04722.JPG JPG image
DSC01718.JPG JPG image
DSC04728.JPG JPG image
DSC01717.JPG JPG image
DSC04182.JPG JPG image
DSC04217.JPG JPG image
DSC04727.JPG JPG image
DSC04720.JPG JPG image
05_-_GLEN19-2013_Design_Analysis_Redacted(RS).pdf PDF
13_Wage_Determination.pdf PDF
09_-_UFGS_14_24_23.pdf PDF
06_-_GLEN19-2013_Drawings_PDF.pdf PDF
10_-_SOW_Environmental_Supplement.pdf PDF
00_Solicitation_-_FA255019RA011.pdf PDF
1_SAFB_Security_Requirements.pdf PDF
4_-_Design_Guide_Version_March_2017.pdf PDF
07_-_UFGS_14_21_23.pdf PDF
2_-_Blank_Contractor_Access_Sheet.xlsx XLSX spreadsheet
3_-_Color_Scheme_Blue_Grey.pdf PDF
11_-_GLEN19-2013_AF_66_Submittal_Register.xls XLS spreadsheet
0_GLEN19-2013_SOW.pdf PDF
Show all 45

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USACE / NAVFAC / AFCEC / NASA UFGS- 14 24 13 ( May 2016) Change 1- 05/ 18 Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 14 24 00 ( August 2010)

UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ONS

Ref er ences ar e i n agr eement wi t h UMRL dat ed Apr i l 2019

SECTI ON TABLE OF CONTENTS

DI VI SI ON 14 - CONVEYI NG EQUI PMENT

HYDRAULI C FREI GHT ELEVATORS

05/16

PART 1 GENERAL

1. 1 REFERENCES

1. 2 SUBMI TTALS

1. 2. 1 Shop Dr awi ng Requi r ement s

1. 2. 2 Pr oduct Dat a Requi r ement s

1. 2. 3 Desi gn Dat a

1. 2. 3. 1 React i on Loads

1. 2. 3. 2 Heat Loads

1. 2. 3. 3 Emer gency Power Syst ems

1. 2. 4 Wel der s ' Requi r ement s

1. 2. 5 Mai nt enance Cont r ol Pr ogr am ( MCP)

1. 3 QUALI TY ASSURANCE

1. 3. 1 Qual i f i cat i on

1. 3. 1. 1 El evat or Cont r act or ' s El evat or Techni c i ans

1. 3. 2 Manuf act ur er s ' Techni cal Suppor t

1. 3. 3 Oper at i on and Mai nt enance Dat a

1. 3. 4 Wi r i ng Di agr ams

1. 3. 5 Machi ne Room/ Cont r ol Room Cabi net

1. 4 NEW I NSTALLATI ON SERVI CE

1. 4. 1 Per i odi c El evat or Cer t i f i cat i on I nspect i on and Test i ng

1. 5 FI RE PROTECTI ON SYSTEM

1. 5. 1 Fi r e Al ar m I ni t i at i ng Devi ces

1. 5. 2 Fi r e Spr i nkl er s

1. 5. 3 Shunt Tr i p Di sconnect

PART 2 PRODUCTS

2. 1 ELEVATOR DESCRI PTI ON

2. 1. 1 El evat or Desi gn Par amet er s

2. 1. 2 Cab Encl osur e and Hoi st way Ent r ance Assembl i es

2. 2 ELEVATOR OPERATI ON

2. 2. 1 Si ngl e, Two- St op, Aut omat i c Oper at i on

2. 2. 2 Sel ect i ve Col l ect i ve Aut omat i c Oper at i on

2. 2. 3 Dupl ex Sel ect i ve Col l ect i ve Aut omat i c Oper at i on

2. 2. 4 Gr oup Aut omat i c Oper at i on

2. 3 SPECI AL OPERATI ON AND CONTROL

SECTI ON 14 24 13 Page 1

2. 3. 1 Keys f or El evat or Key Swi t ches

2. 3. 2 Fi r ef i ght er s ' Emer gency Oper at i on ( FEO)

2. 3. 2. 1 Fi r ef i ght er s ' Emer gency Oper at i on ( FEO) Key Box

2. 3. 3 Hoi st way Access Oper at i on

2. 3. 4 I n- Car I nspect i on Oper at i on

2. 3. 5 I ndependent Ser vi ce

2. 3. 6 Sel ect i ve Door Oper at i on

2. 3. 7 El evat or Emer gency Power Oper at i on

2. 3. 8 El evat or Auxi l i ar y Power Oper at i ng Syst em

2. 4 ELEVATOR DRI VE SYSTEM

2. 4. 1 Hydr aul i c Pump Uni t

2. 4. 1. 1 Pump Mot or

2. 4. 2 Hydr aul i c Cont r ol s and Equi pment

2. 4. 2. 1 Hydr aul i c Cont r ol Val ve

2. 4. 2. 2 Hydr aul i c Over speed Saf et y Val ve

2. 4. 3 Hydr aul i c Pi pi ng and Accessor i es

2. 4. 3. 1 Cont ai nment of Hydr aul i c Oi l Suppl y Li ne

2. 4. 4 Hydr aul i c El evat or Type

2. 4. 4. 1 Cyl i nder - Pl unger ( Jack) Uni t

2. 4. 5 Cyl i nder Wel l Syst em

2. 4. 5. 1 Wel l Casi ng

2. 4. 5. 2 PVC or HDPE Li ner

2. 4. 5. 3 Cyl i nder I nst al l at i on

2. 4. 5. 4 Cyl i nder Li ner Moi st ur e Sensor Syst em

2. 4. 5. 5 Seal Top of Wel l Casi ng

2. 5 CONTROL EQUI PMENT

2. 5. 1 Mot or Cont r ol Equi pment

2. 5. 2 El evat or Mi cr opr ocessor Cont r ol l er

2. 5. 2. 1 El evat or Cont r ol l er I nt er f ace Cabi net

2. 5. 2. 1. 1 El evat or Mi cr opr ocessor Human I nt er f ace

2. 5. 2. 2 Sof t war e and Document at i on

2. 5. 2. 3 El evat or Cont r ol l er Cer t i f i cat i on

2. 6 OPERATI NG PANELS, SI GNAL FI XTURES, AND COMMUNI CATI ONS CABI NETS

2. 6. 1 Car and Hal l But t ons

2. 6. 1. 1 Hal l St at i on Door - Oper at i ng But t ons

2. 6. 2 Fr ei ght Car - Oper at i ng Panel

2. 6. 2. 1 Oper at or Cont r ol s

2. 6. 2. 2 Ser vi ce Cont r ol s

2. 6. 2. 3 Cer t i f i cat e Wi ndow

2. 6. 2. 4 Emer gency Si gnal i ng Devi ces

2. 6. 3 El evat or I n- Car Posi t i on I ndi cat or s

2. 6. 4 El evat or I n- Car Di r ect i on I ndi cat or s

2. 6. 5 Hal l Cal l Landi ng Fi xt ur es

2. 6. 5. 1 Desi gnat ed Landi ng Hal l Cal l Fi xt ur e

2. 6. 5. 1. 1 Locat i on of COMMUNI CATI ON MEANS FAI LURE ( CMF) Vi sual

Signal

2. 6. 5. 1. 2 COMMUNI CATI ON MEANS FAI LURE ( CMF) Vi sual and Audi bl e

Si gnal Oper at i on

2. 6. 5. 1. 3 Fi r ef i ght er s ' Emer gency Oper at i on Phase I Swi t ch and

Vi sual Si gnal

2. 6. 6 El evat or Car Posi t i on and Di r ect i on I ndi cat or s and Car Ar r i val

Signal

2. 6. 7 Desi gnat ed Landi ng El evat or I dent i f i cat i on Fi xt ur e

2. 6. 8 Emer gency or St andby Power

2. 7 CAR DOOR EQUI PMENT

2. 7. 1 Car Door Oper at or

2. 7. 2 I nf r a- r ed Cur t ai n Uni t

2. 8 FREI GHT ELEVATOR GUI DES, PLATFORM, AND ENCLOSURE

2. 8. 1 Gui des

SECTI ON 14 24 13 Page 2

2. 8. 2 Car Shel l Ret ur n Panel s, Door s, Ent r ance Col umns, and Tr ansom

2. 8. 3 Car Encl osur e Top

2. 8. 4 Car Door

2. 8. 5 Car Ent r ance Si l l

2. 8. 6 I n- Car Hor i zont al Buck- Boar d Wal l Pr ot ect i on

2. 8. 7 Cab Fi ni sh Fl oor

2. 8. 8 Car Fan

2. 8. 9 Car Li ght i ng

2. 9 FREI GHT ELEVATOR HOI STWAY DOORS AND ENTRANCES

2. 9. 1 Hoi st way Ent r ance Fr ames

2. 9. 2 Hoi st way Ent r ance Si l l s

2. 10 HOI STWAY EQUI PMENT

2. 10. 1 Car Gui de Rai l s and Fast eni ngs

2. 10. 2 Pi t Equi pment

2. 10. 3 Pi t " STOP" Swi t ch

2. 10. 4 Tr avel i ng Cabl es

2. 10. 5 Hoi st way Pi t Ladder

PART 3 EXECUTI ON

3. 1 I NSTALLATI ON

3. 1. 1 St r uct ur al Member s and Fi ni sh Mat er i al s

3. 1. 2 Mi scel l aneous Requi r ement s

3. 2 FI ELD QUALI TY CONTROL

3. 3 ACCEPTANCE I NSPECTI ON, TESTI NG AND COMMI SSI ONI NG

3. 3. 1 Accept ance I nspect i on Suppor t

3. 3. 2 Test i ng Mat er i al s and I nst r ument s

3. 3. 3 Fi el d Test s

3. 3. 3. 1 Endur ance Test s

3. 3. 3. 2 Speed Test s

3. 3. 3. 3 Level i ng Test s

3. 3. 3. 4 Temper at ur e Ri se Test s

3. 3. 3. 5 Mot or Amper e Test s

3. 3. 3. 6 El evat or Per f or mance and Ri de Qual i t y Test i ng

3. 3. 3. 7 Hydr aul i c Saf et y Val ve ( Aut omat i c Shut of f Val ve) Test s

3. 3. 3. 8 Hydr aul i c Pr essur e Test s

3. 3. 3. 9 Pr essur e Test of Li ner / Cyl i nder Assembl y

- - End of Sect i on Tabl e of Cont ent s - -

SECTI ON 14 24 13 Page 3

USACE / NAVFAC / AFCEC / NASA UFGS- 14 24 13 ( May 2016) Change 1- 05/ 18 Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 14 24 00 ( August 2010)

UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ONS

Ref er ences ar e i n agr eement wi t h UMRL dat ed Apr i l 2019

SECTI ON 14 24 13

HYDRAULI C FREI GHT ELEVATORS

05/16

NOTE: Thi s gui de speci f i cat i on cover s t he r equi r ement s f or hydr aul i c f r ei ght el evat or s.

Adher e t o UFC 1- 300- 02 Uni f i ed Faci l i t i es Gui de Speci f i cat i ons ( UFGS) For mat St andar d when edi t i ng t hi s gui de speci f i cat i on or pr epar i ng new pr oj ect speci f i cat i on sect i ons. Edi t t hi s gui de speci f i cat i on f or pr oj ect speci f i c r equi r ement s by addi ng, del et i ng, or r evi s i ng t ext . For br acket ed i t ems, choose appl i cabl e i t em( s) or i nser t appr opr i at e i nf or mat i on.

Remove i nf or mat i on and r equi r ement s not r equi r ed i n r espect i ve pr oj ect , whet her or not br acket s ar e present.

Comment s, suggest i ons and r ecommended changes f or t hi s gui de speci f i cat i on ar e wel come and shoul d be submi t t ed as a Cr i t er i a Change Request ( CCR) .

NOTE: Al l Ar my and Navy f aci l i t y desi gns whi ch i ncl ude el evat or s shal l compl y wi t h t he " NAVFAC I TG 2013- 01 El evat or Desi gn" . Thi s gui de i s avai l abl e f r om t he NAVFAC f aci l i t at or ( http://www.wbdg.org/ffc/navy-navfac/interim-technical-guidance-itg ) under I nt er i m Techni cal Gui dance.

NOTE: For NAVY pr oj ect s, any edi t i ng of non- br acket ed r equi r ement s i n t hi s speci f i cat i on shal l be appr oved t hr ough t he NAVFAC FEC VTE Pr ogr am Lead Cer t i f y i ng Of f i c i al .

SECTI ON 14 24 13 Page 4

PART 1 GENERAL

1. 1 REFERENCES

NOTE: Thi s par agr aph i s used t o l i s t t he publ i cat i ons c i t ed i n t he t ext of t he gui de speci f i cat i on. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by basi c desi gnat i on onl y and l i s t ed i n t hi s par agr aph by or gani zat i on, desi gnat i on, dat e, and t i t l e.

Use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e when you add a Ref er ence I dent i f i er ( RI D) out s i de of t he Sect i on' s Ref er ence Ar t i c l e t o aut omat i cal l y pl ace t he r ef er ence i n t he Ref er ence Ar t i c l e. Al so use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e t o updat e t he i ssue dat es.

Ref er ences not used i n t he t ext wi l l aut omat i cal l y be del et ed f r om t hi s sect i on of t he pr oj ect speci f i cat i on when you choose t o r econci l e r ef er ences i n t he publ i sh pr i nt pr ocess.

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

AMERI CAN WELDI NG SOCI ETY ( AWS)

AWS D1. 1/ D1. 1M ( 2015; Er r at a 1 2015; Er r at a 2 2016) St r uct ur al Wel di ng Code - St eel

ASME I NTERNATI ONAL ( ASME)

ASME A17. 1/ CSA B44 ( 2016) Saf et y Code f or El evat or s and Escalators

ASME A17. 2 ( 2017) Gui de f or I nspect i on of El evat or s, Escal at or s, and Movi ng Wal ks I ncl udes I nspect i on Pr ocedur es f or El ect r i c Tr act i on and Wi ndi ng Dr um El evat or s, Hydr aul i c El evat or s, and Escal at or s and Movi ng Wal ks

ASME B16. 11 ( 2016) For ged Fi t t i ngs, Socket - Wel di ng and Threaded

ASME B16. 9 ( 2018) Fact or y- Made Wr ought But t wel di ng Fittings

ASTM I NTERNATI ONAL ( ASTM)

ASTM A106/ A106M ( 2018) St andar d Speci f i cat i on f or Seaml ess Car bon St eel Pi pe f or Hi gh- Temper at ur e Service

ASTM A53/ A53M ( 2018) St andar d Speci f i cat i on f or Pi pe, SECTI ON 14 24 13 Page 5

St eel , Bl ack and Hot - Di pped, Zi nc- Coat ed, Wel ded and Seaml ess

I NSTI TUTE OF ELECTRI CAL AND ELECTRONI CS ENGI NEERS ( I EEE)

I EEE C62. 41 ( 1991; R 1995) Recommended Pr act i ce on Sur ge Vol t ages i n Low- Vol t age AC Power Circuits

I NTERNATI ONAL CODE COUNCI L ( I CC)

I CC I BC ( 2018) I nt er nat i onal Bui l di ng Code

NATI ONAL ELEVATOR I NDUSTRY, I NC. ( NEI I )

NEII-1 ( 2000; R t hr u 2017) Bui l di ng Tr anspor t at i on St andar ds and Gui del i nes, i ncl udi ng t he Per f or mance St andar ds Mat r i x f or New El evat or I nst al l at i on

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 101 ( 2018; TI A 18- 1; TI A 18- 2; TI A 18- 3) Li f e Saf et y Code

NFPA 70 ( 2017; ERTA 1- 2 2017; TI A 17- 1; TI A 17- 2;

TI A 17- 3; TI A 17- 4; TI A 17- 5; TI A 17- 6;

TI A 17- 7; TI A 17- 8; TI A 17- 9; TI A 17- 10;

TI A 17- 11; TI A 17- 12; TI A 17- 13; TI A

17- 14; TI A 17- 15; TI A 17- 16; TI A 17- 17 )

Nat i onal El ect r i cal Code

NFPA 70E ( 2018; TI A 18- 1; TI A 81- 2) St andar d f or El ect r i cal Saf et y i n t he Wor kpl ace

NFPA 72 ( 2019; TI A 19- 1; ERTA 2019) Nat i onal Fi r e Al ar m and Si gnal i ng Code

U. S. DEPARTMENT OF DEFENSE ( DOD)

UFC 3- 560- 01 ( 2017, wi t h Change 1, 2018) Oper at i ons and Mai nt enance: El ect r i cal Saf et y

U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)

36 CFR 1191 Amer i cans wi t h Di sabi l i t i es Act ( ADA) Accessi bi l i t y Gui del i nes f or Bui l di ngs and Faci l i t i es; Ar chi t ect ur al Bar r i er s Act ( ABA) Accessi bi l i t y Gui del i nes

1. 2 SUBMITTALS

NOTE: Revi ew Submi t t al Descr i pt i on ( SD) def i ni t i ons i n Sect i on 01 33 00 SUBMI TTAL PROCEDURES and edi t t he f ol l owi ng l i s t t o r ef l ect onl y t he submi t t al s r equi r ed f or t he pr oj ect .

The Gui de Speci f i cat i on t echni cal edi t or s have

SECTI ON 14 24 13 Page 6 desi gnat ed t hose i t ems t hat r equi r e Gover nment appr oval , due t o t hei r compl exi t y or cr i t i cal i t y , wi t h a " G. " Gener al l y, ot her submi t t al i t ems can be r evi ewed by t he Cont r act or ' s Qual i t y Cont r ol Syst em. Onl y add a " G" t o an i t em, i f t he submi t t al i s suf f i c i ent l y i mpor t ant or compl ex i n cont ext of t he pr oj ect .

For submi t t al s r equi r i ng Gover nment appr oval on Ar my pr oj ect s, a code of up t o t hr ee char act er s wi t hi n t he submi t t al t ags may be used f ol l owi ng t he " G" desi gnat i on t o i ndi cat e t he appr ovi ng aut hor i t y.

Codes f or Ar my pr oj ect s usi ng t he Resi dent Management Syst em ( RMS) ar e: " AE" f or Ar chi t ect - Engi neer ; " DO" f or Di st r i c t Of f i ce ( Engi neer i ng Di v i s i on or ot her or gani zat i on i n t he Di st r i c t Of f i ce) ; " AO" f or Ar ea Of f i ce; " RO" f or Resi dent Of f i ce; and " PO" f or Pr oj ect Of f i ce. Codes f ol l owi ng t he " G" t ypi cal l y ar e not used f or Navy, Ai r For ce, and NASA pr oj ect s.

The " S" f ol l owi ng a submi t t al i t em i ndi cat es t hat t he submi t t al i s r equi r ed f or t he Sust ai nabi l i t y eNot ebook t o f ul f i l l f eder al l y mandat ed sust ai nabl e r equi r ement s i n accor dance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG. Locat e t he " S" submi t t al under t he SD number t hat best descr i bes t he submi t t al i t em.

Choose t he f i r st br acket ed i t em f or Navy, Ai r For ce and NASA pr oj ect s, or choose t he second br acket ed i t em f or Ar my pr oj ect s.

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e [ f or Cont r act or Qual i t y Cont r ol appr oval . ] [ f or i nf or mat i on onl y. When used, a desi gnat i on f ol l owi ng t he " G" desi gnat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . ] Submi t t al s wi t h an " S" ar e f or i ncl usi on i n t he Sust ai nabi l i t y eNot ebook, i n conf or mance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG. Submi t t he f ol l owi ng i n accor dance wi t h Sect i on

01 33 00 SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

El evat or Syst em; G[ , [ _____] ]

El evat or Component s; G[ , [ _____] ]

El evat or Machi ne; G[ , [ _____] ]

El evat or Cont r ol l er ; G[ , [ _____] ]

Wi r i ng Di agr ams; G[ , [ _____] ]

SD- 03 Pr oduct Dat a

NOTE: For Ar my pr oj ect s, del et e t he br acket ed

SECTI ON 14 24 13 Page 7 i t ems. For Navy pr oj ect s, keep t he br acket ed i t ems.

El evat or and Accessor i es[ ; G[ , [ _____] ] ]

El evat or Component s[ ; G[ , [ _____] ] ]

Dat a Sheet s[ ; G[ , [ _____] ] ]

El evat or Mi cr opr ocessor Cont r ol l er ; G[ , [ _____] ]

SD- 05 Desi gn Dat a

Emer gency Power Syst ems

Heat Loads

React i on Loads

SD- 07 Cer t i f i cat es

El evat or Par t s and Component s pr i ce l i s t s; G[ , [ _____] ]

Warranty

Endor sement Let t er

Wel der s ' Qual i f i cat i ons

El evat or Cont r ol l er Cer t i f i cat i on; G[ , [ _____] ]

SD- 10 Oper at i on and Mai nt enance Dat a

El evat or , Dat a Package 4; G[ , [ _____] ]

Mai nt enance Cont r ol Pr ogr am ( MCP) ; G[ , [ _____] ]

Sof t war e and Document at i on; G[ , [ _____] ]

Submi t i n accor dance wi t h Sect i on 01 78 23 OPERATI ON AND MAI NTENANCE DATA and 01 78 24. 05 20 FACI LI TY OPERATI ON AND

MAI NTENANCE SUPPORT I NFORMATI ON.

1. 2. 1 Shop Dr awi ng Requi r ement s

Pr ovi de assembl y and ar r angement of el evat or s, accessor i es, and el evat or component s. Show l ocat i on of el evat or machi ne i n el evat or machi ne r oom ( MR) or i n el evat or machi ner y space ( MS) . Show l ocat i on of el evat or cont r ol l er i n el evat or machi ne r oom or el evat or cont r ol r oom ( CR) . Pr ovi de det ai l s f or mat er i al s and equi pment , i ncl udi ng but not l i mi t ed t o oper at i ng and si gnal f i x t ur es, door s, door and car f r ames, car encl osur e, cont r ol l er s, mot or s, gui de r ai l s and br acket s, l ayout of hoi st way i n pl an and el evat i on, and ot her l ayout i nf or mat i on and cl ear ance di mensi ons.

1. 2. 2 Pr oduct Dat a Requi r ement s

Pr ovi de manuf act ur er s ' pr oduct dat a f or al l el evat or component s, i ncl udi ng but not l i mi t ed t o t he f ol l owi ng: el evat or cont r ol l er , hydr aul i c pump uni t , hydr aul i c pump and mot or , hydr aul i c cyl i nder , hydr aul i c pi pi ng and

SECTI ON 14 24 13 Page 8 f i t t i ngs, car and hal l f i x t ur e but t ons and swi t ches, cab and machi ne r oom or cont r ol r oom communi cat i on devi ces, door oper at or , door pr ot ect i on syst em, car r ol l er gui des, and buf f er s. For dat a sheet s, pr ovi de document i dent i f i cat i on number or bul l et i n number , publ i shed or copyr i ght ed pr i or t o t he dat e of cont r act bi d openi ng. Pr ovi de cont r ol l er manuf act ur er ' s publ i shed pr ocedur es f or per f or mance of each and al l t est i ng r equi r ed by

ASME A17. 1/ CSA B44.

1. 2. 3 Desi gn Dat a

1. 2. 3. 1 React i on Loads

Pr ovi de cal cul at i ons by r egi st er ed pr of essi onal engi neer f or r eact i on l oads i mposed on bui l di ng by el evat or syst em. Demonst r at e cal cul at i ons compl yi ng with ASME A17. 1/ CSA B44

1. 2. 3. 2 Heat Loads

Pr ovi de cal cul at i ons f r om el evat or manuf act ur er , or by r egi st er ed pr of essi onal engi neer , f or t ot al ant i c i pat ed heat l oads gener at ed by al l of t he el evat or equi pment .

1. 2. 3. 3 Emer gency Power Syst ems

Wher e t he f aci l i t y does have an emer gency power syst em, conf i r m t he el evat or s t hat wi l l be connect ed t o t he emer gency power syst em. Conf i r m t he compl et e emer gency power syst em and sequence of oper at i on f or al l el evat or s, i ncl udi ng oper at i on of t he el evat or l obby manual sel ect i on swi t ch. Pr ovi de wi r i ng di agr ams f or bui l di ng emer gency power i nt er f ace wi t h el evat or cont r ol s. For el evat or s not suppl i ed by an emer gency power syst em, pr ovi de manuf act ur er s ' pr oduct dat a f or auxi l i ar y power syst ems.

1. 2. 4 Wel der s ' Requi r ement s

Compl y wi t h AWS D1. 1/ D1. 1M, Sect i on 5. I ncl ude cer t i f i ed copi es of f i el d wel der s ' qual i f i cat i ons. Li st wel der s ' names wi t h cor r espondi ng code mar ks t o i dent i f y each wel der ' s wel di ng wor k.

1. 2. 5 Mai nt enance Cont r ol Pr ogr am ( MCP)

For each el evat or , pr epar e and pr ovi de a wr i t t en Mai nt enance Cont r ol Pr ogr am ( MCP) t hat compl i es wi t h ASME A17. 1/ CSA B44 Sect i on 8. 6, i ncl udi ng wr i t t en document at i on t hat det ai l s t he t est pr ocedur es f or each and ever y t est t hat i s r equi r ed t o be per f or med by ASME A17. 1/ CSA B44. Assembl e al l MCP document at i on, and suppor t i ng t echni cal at t achment s, i n a s i ngl e MCP package and pr ovi de i n bot h el ect r oni c and har d copy. Assembl e ent i r e har d copy MCP i n 3- r i ng bi nder s. For each el evat or pr ovi ded, t he MCP must i ncl ude onl y document at i on and i nst r uct i on t hat appl y t o t he el evat or specified.

For each el evat or , pr ovi de an addi t i onal , separ at e bi nder t hat i ncl udes al l mai nt enance, r epai r , r epl acement , cal l back, and ot her r ecor ds r equi r ed by ASME A17. 1/ CSA B44. The r ecor ds bi nder must be kept i n t he el evat or mechani cal r oom, mai nt ai ned by el evat or mai nt enance and ser vi ce per sonnel , and be avai l abl e at al l t i mes t o aut hor i zed per sonnel .

Pr ovi de det ai l ed i nf or mat i on r egar di ng emer gency ser vi ce pr ocedur es and el evat or i nst al l at i on company per sonnel cont act i nf or mat i on. Pr ovi de a l i s t i ng of al l t ool s t o be pr ovi ded t o t he Cont r act i ng Of f i cer as

SECTI ON 14 24 13 Page 9 component s of t he el evat or syst em.

1. 3 QUALI TY ASSURANCE

1. 3. 1 Qualification

Pr ovi de a desi gned and engi neer ed el evat or syst em by an el evat or cont r act or r egul ar l y engaged i n t he i nst al l at i on of el evat or syst ems. Pr ovi de el evat or component s manuf act ur ed by compani es r egul ar l y engaged i n t he manuf act ur e of el evat or component s. Ut i l i ze onl y l i censed and cer t i f i ed el evat or per sonnel f or t he i nst al l at i on, adj ust i ng, t est i ng, and ser vi c i ng of t he el evat or s.

1. 3. 1. 1 El evat or Cont r act or ' s El evat or Techni c i ans

For el evat or i nst al l at i ons i n t he Uni t ed St at es, i ncl udi ng Uni t ed St at es t er r i t or i es, per f or m al l el evat or r el at ed wor k under t he di r ect gui dance of a st at e cer t i f i ed el evat or t echni c i an wi t h a mi ni mum of t hr ee year s of exper i ence i n t he i nst al l at i on of el evat or syst ems of t he t ype and compl exi t y speci f i ed i n t he cont r act document s. Pr ovi de an endor sement l et t er f r om t he el evat or manuf act ur er , cer t i f y i ng t hat t he el evat or speci al i s t i s qual i f i ed. Al l el evat or t echni c i ans must car r y a cur r ent cer t i f i cat i on i ssued by one of t he f ol l owi ng or gani zat i ons:

a. Nat i onal Associ at i on of El evat or Cont r act or s ( NAEC)

b. Nat i onal El evat or I ndust r y Educat i on Pr ogr am ( NEI EP)

1. 3. 2 Manuf act ur er s ' Techni cal Suppor t

Pr ovi de el evat or component s f r om manuf act ur er s t hat pr ovi de f act or y t r ai ni ng and onl i ne and l i ve t el ephone el evat or t echni cal suppor t t o any el evat or i nst al l at i on, ser vi ce, and mai nt enance cont r act or . Pr ovi de el evat or component s f r om manuf act ur er s t hat guar ant ee accessi bi l i t y t o al l r epl acement and r epai r par t s and component s t o any el evat or i nst al l at i on, ser vi ce, and mai nt enance cont r act or . Use onl y el evat or component manuf act ur er s t hat pr ovi de cur r ent publ i shed pr i ce l i s t s f or al l el evat or par t s and component s.

1. 3. 3 Oper at i on and Mai nt enance Dat a

Assembl e al l shop dr awi ng and pr oduct dat a mat er i al i nt o O&M Dat a Packages i n accor dance wi t h Ar t i c l e SUBMI TTALS. Pr ovi de t wo compl et e O&M Dat a Packages i n har d copy and t wo compl et e el ect r oni c O&M dat a packages on separ at e CDs, i n PDF f or mat . Pr ovi de al l O&M Dat a Packages t o Cont r act i ng Of f i cer . I ncl ude cont r ol l er di agnost i c document at i on and sof t war e as r equi r ed under Ar t i c l e CONTROL EQUI PMENT.

1. 3. 4 Wi r i ng Di agr ams

Pr ovi de compl et e wi r i ng di agr ams and sequence of oper at i ons, whi ch show el ect r i cal connect i ons and f unct i ons of el evat or syst ems. Pr ovi de one set ( 279 mm by 432 mm11 i nch by 17 i nch mi ni mum si ze) of wi r i ng di agr ams, wi t h i ndi v i dual sheet s l ami nat ed i n pl ast i c and assembl ed i n bi nder , t o be st or ed i n t he machi ne r oom or cont r ol r oom cabi net . Pr ovi de one addi t i onal har d copy set and t wo compl et e el ect r oni c set s on separ at e CDs, i n PDF f or mat . Pr ovi de al l wi r i ng di agr am set s t o t he Cont r act i ng Of f i cer . Coded di agr ams ar e not accept abl e unl ess f ul l y i dent i f i ed.

SECTI ON 14 24 13 Page 10

1. 3. 5 Machi ne Room/ Cont r ol Room Cabi net

For st or age of O&M Dat a Packages and Wi r i ng Di agr ams, pr ovi de l ocki ng met al cabi net wi t h a mi ni mum si ze of 508 mm W by 305 mm D by 762 mm H 20 i nch W by 12 i nch D by 30 i nch H. Cabi net must be s i zed l ar ge enough t o accommodat e al l O&M Dat a and har dwar e r equi r ed i n par agr aphs OPERATI ON AND MAI NTENANCE DATA and WI RI NG DI AGRAMS. Secur e cabi net t o machi ne r oom or cont r ol r oom wal l .

1. 4 NEW I NSTALLATI ON SERVI CE

NOTE: Use Bi - weekl y opt i on f or Hospi t al s and ot her hi gh use f aci l i t i es.

Pr ovi de el evat or war r ant y ser vi ce i n accor dance wi t h t he manuf act ur er ' s mai nt enance pl an, war r ant y r equi r ement s and appl i cabl e saf et y codes, f or a per i od of 12 mont hs af t er t he dat e of accept ance by Cont r act i ng Of f i cer .

Per f or m t hi s wor k dur i ng r egul ar wor ki ng hour s. Pr ovi de suppl i es and par t s t o keep el evat or syst em i n oper at i on. Per f or m ser vi ce onl y by f act or y t r ai ned per sonnel . Pr ovi de [ Mont hl y] [ Bi - weekl y] ser vi ces t o i ncl ude r epai r s, adj ust ment s, gr easi ng, oi l i ng, and cl eani ng. Pr ovi de ser v i ce l og i n el evat or machi ne r oom or cont r ol r oom and updat e [ Mont hl y] [ Bi - weekl y] , t hr oughout t he one- year war r ant y per i od.

NOTE: One hour emer gency ser vi ce bel ow i s st andar d;

onl y use t wo hour f or r emot e l ocat i ons.

Pr ovi de 24- hour emer gency ser vi ce, wi t h [ one hour ] [ t wo hour ] on- si t e r esponse t i me, dur i ng t hi s per i od wi t hout addi t i onal cost t o t he Gover nment .

1. 4. 1 Per i odi c El evat or Cer t i f i cat i on I nspect i on and Test i ng

Pr ovi de el evat or mechani c t o suppor t [ NAVFAC ] QEI Cer t i f i ed El evat or I nspect or i n t he per i odi c s i x- mont h and t he annual Cat egor y 1 el evat or cer t i f i cat i on i nspect i on and t est i ng. Per f or m Cat egor y 1 i nspect i on and t est i ng no gr eat er t han 30 days pr i or t o t he end of t he war r ant y per i od.

Per f or m al l el evat or cer t i f i cat i on t est i ng i n t he pr esence of QEI Cer t i f i ed El evat or I nspect or .

I n conj unct i on wi t h t he t est i ng not ed above, t est syst ems f or Emer gency Power Oper at i on, Ear t hquake Emer gency Oper at i on, and Hospi t al Emer gency Commandeer i ng Ser vi ce Oper at i on, as appl i cabl e. Schedul e so t hat t est i ng does not i nt er f er e wi t h bui l di ng oper at i ons.

1. 5 FI RE PROTECTI ON SYSTEM

NOTE: Conf i r m t hat sect i ons l i s t ed t hr oughout t hi s ar t i c l e ar e par t of pr oj ect . Add or del et e sect i ons as needed f or pr oj ect .

Coor di nat e i nt er f ace bet ween bui l di ng f i r e pr ot ect i on syst em and el evat or controls.

SECTI ON 14 24 13 Page 11

Addi t i onal f i r e pr ot ect i on r equi r ement s ar e l ocat ed i n: [ Sect i on 28 31 74. 00 20 I NTERI OR FI RE DETECTI ON AND ALARM SYSTEM; ] [ Sect i on

28 31 02. 00 20 FI RE ALARM REPORTI NG SYSTEMS - DI GI TAL COMMUNI CATORS; ] [

Sect i on 21 13 13. 00 20 WET PI PE SPRI NKLER SYSTEM, FI RE PROTECTI ON; ] [ _____] and Sect i on 26 20 00 I NTERI OR DI STRI BUTI ON SYSTEM.

1. 5. 1 Fi r e Al ar m I ni t i at i ng Devi ces

Fi r e al ar m i ni t i at i ng devi ces ar e speci f i ed i n [ Sect i on 28 31 74. 00 20 I NTERI OR FI RE DETECTI ON AND ALARM SYSTEM] [ _____] , i ncl udi ng condui t and wi r i ng f r om each det ect or t o f i r e pr ot ect i on addr essabl e modul es i n el evat or machi ne r oom or cont r ol r oom.

1. 5. 2 Fi r e Spr i nkl er s

Pr ovi de f i r e spr i nkl er s i n accor dance wi t h al l appl i cabl e saf et y codes and wi t h [ Sect i on 21 13 13. 00 20 WET PI PE SPRI NKLER SYSTEM, FI RE PROTECTI ON] [ _____] . Pr ovi de shut of f val ve, check val ve, and non- adj ust abl e, zer o t i me- del ay f l ow swi t ch, i n each spr i nkl er l i ne i mmedi at el y out s i de of each machi ne r oom, cont r ol r oom, and hoi st way, as appl i cabl e. Pr ovi de i nspect or s ' t est val ve f or per i odi c t est i ng of f l ow swi t ch and shunt t r i p disconnect.

Pi pe spr i nkl er pi pi ng ser vi ng t hese spaces i n a ser i es manner wi t h no l at er al s. Locat e i nspect or s ' t est connect i on at t he end of pi pe r uns such t hat oper at i on of t he t est connect i on wi l l pur ge ai r f r om syst em pi pi ng.

1. 5. 3 Shunt Tr i p Di sconnect

Pr ovi de f l ow swi t ches speci f i ed i n par agr aph FI RE SPRI NKLERS t o compl y wi t h ASME A17. 1/ CSA B44 and NFPA 72 f or shunt t r i p of t he mai n l i ne power suppl y. For each el evat or , pr ovi de cont r ol wi r i ng connect i ng t he f l ow swi t ch t o a shunt t r i p equi pped c i r cui t br eaker l ocat ed i n t he el evat or machi ne r oom or cont r ol r oom. Upon f l ow of wat er , f l ow swi t ch wi l l i nst ant aneousl y cause openi ng of t he shunt - t r i p c i r cui t br eaker and r emove power f r om t he el evat or . Fl ow swi t ch must al so send a s i gnal t o f i r e al ar m cont r ol panel t o i ndi cat e wat er f l ow condi t i on.

PART 2 PRODUCTS

2. 1 ELEVATOR DESCRI PTI ON

Pr ovi de el evat or syst em t hat compl i es wi t h ASME A17. 1/ CSA B44 i n i t s entirety, ASME A17. 2 i n i t s ent i r et y, and addi t i onal r equi r ement s speci f i ed her ei n. Pr ovi de el evat or syst em t hat meet s or exceeds t he NEII-1 Ri de Qual i t y Per f or mance St andar ds Mat r i x ( RQPSM) . Compl y wi t h t he RQPSM " I nt er medi at e Per f or mance" cr i t er i a.

Pr ovi de and i nst al l el evat or s i n accor dance wi t h 36 CFR 1191 - ABAAS, I CC I BC, I EEE C62. 41, NFPA 70 and NFPA 101 r equi r ement s.

2. 1. 1 El evat or Desi gn Par amet er s

NOTE: Tr af f i c Anal ysi s and Mi ni mum Cab Si ze

Per f or m a t r af f i c anal ysi s and conduct i nt er v i ews wi t h t he f aci l i t y user t o det er mi ne number , s i ze, and t ype of el evat or s necessar y t o ser ve t he needs

SECTI ON 14 24 13 Page 12 of t he f aci l i t y user . For Ar my and Navy pr oj ect s, ut i l i ze NAVFAC I TG 2013- 01 El evat or Desi gn t o det er mi ne Desi gn Type. For mi ni mum el evat or speed, speci f y 0. 64 MPs 125 f pm f or 2 st or y and 0. 75 MPs 150 f pm f or 3 and 4 st or y el evat or s.

Use of a hol el ess t ype el evat or wi l l be l i mi t ed t o a maxi mum t r avel di st ance of 386 cm 12 f t - 8 i n.

a. Type: [ I n- Gr ound Di r ect Pl unger ] [ Hol el ess]

b. Rat ed l oad: [ _____] kg l b.

c. Rat ed Speed: [ 0. 64] [ 0. 75] MPs [ 125] [ 150] f pm

d. Car I nsi de Di mensi ons: [ _____] cm f t . [ _____] cm i n. wi de, [ _____] cm f t . [ _____] cm i n. deep and [ _____] cm f t . [ _____] cm i n. hi gh

e. Hoi st way Door Type & Si ze: [ Manual ] [ Power oper at ed] Ver t i cal [ Ri s i ng] [ Bi - Par t i ng] [ _____] cm f t . [ _____] cm i n. wi de and [ _____] cm f t .

[ _____] cm i n. hi gh f . Car Gat e Type: [ Manual ] [ Power oper at ed] Ver t i cal Ri s i ng

NOTE: Ref er t o ASME A17. 1/ CSA B44 f or Cl asses of loading.

g. Loadi ng Type: Cl ass [ A] [ B] [ C]

2. 1. 2 Cab Encl osur e and Hoi st way Ent r ance Assembl i es

NOTE: I f r et ai ni ng 1st opt i on i n sent ence bel ow, ensur e t hat f i ni shes ar e i ndi cat ed, most l i kel y somewher e on t he dr awi ngs. I n ei t her case, i ndi cat e f i ni sh col or s of el evat or mat er i al s i n f i ni sh schedul e on dr awi ngs.

NOTE: Speci f y st ai nl ess st eel door s, s i de panel s and wal l t r i m i n hospi t al car s.

Pr ovi de f i ni shes [ as i ndi cat ed. ] [ as l i s t ed bel ow:

a. Fl oor ; [ mi l l f i ni sh st eel di amond pl at e] [ pai nt ed st eel di amond pl at e] [ al umi num di amond pl at e] [ t ongue and gr oove har dwood] [ _____] .

b. Wal l s; [ pr ef i ni shed st eel panel s] [ st ai nl ess st eel ] [ _____] .

Wal l t r i m; [ pr ef i ni shed st eel ] [ st ai nl ess st eel ] [ _____] .

Accessor i es; [ handr ai l ] [ _____]

SECTI ON 14 24 13 Page 13

NOTE: Ret ai n br acket ed phr ase f or f r ei ght el evat or s t hat do not have Fr ont and Rear openi ngs.

Accessor i es; Pr ovi de i n- car hor i zont al buck- boar d wal l pr ot ect i on on f ul l l engt h of s i de wal l s [ and back wal l ] of el evat or cab.

c. Car door s, car door r et ur ns, and wal l r eveal s; [ pr ef i ni shed st eel panel s] [ st ai nl ess st eel ] [ _____] .

d. Cei l i ng; [ pr ef i ni shed st eel panel s] [ st ai nl ess st eel ] [ anodi zed aluminum][_____].

e. Hoi st way Ent r ance Assembl y Mat er i al and Fi ni shes; [ pr ef i ni shed st eel ] [ st ai nl ess st eel ] [ _____] . ]

2. 2 ELEVATOR OPERATI ON

ASME A17. 1/ CSA B44, I nt r oduct i on, Sect i on 3, Def i ni t i ons.

NOTE: Choose one of t he f ol l owi ng f our t ypes of el evat or oper at i on.

[ 2. 2. 1 Si ngl e, Two- St op, Aut omat i c Oper at i on

NOTE: Choose f or s i ngl e el evat or ser vi ng t wo landings.

Pr ovi de Si ngl e Two- St op Aut omat i c Oper at i on.

][ 2. 2. 2 Sel ect i ve Col l ect i ve Aut omat i c Oper at i on

NOTE: Choose f or s i ngl e el evat or ser vi ng t hr ee or mor e l andi ngs.

Pr ovi de Sel ect i ve Col l ect i ve Aut omat i c Oper at i on.

][ 2. 2. 3 Dupl ex Sel ect i ve Col l ect i ve Aut omat i c Oper at i on

NOTE: Choose f or t wo adj acent el evat or s.

Pr ovi de Dupl ex Sel ect i ve Col l ect i ve Aut omat i c Oper at i on. I f a car i s t aken out of ser vi ce or f ai l s t o r espond t o a l andi ng cal l wi t hi n a pr edet er mi ned adj ust abl e t i me l i mi t of appr oxi mat el y 40 t o 180 seconds, t r ansf er cal l s t o t he ot her car f unct i oni ng as a s i ngl e car Sel ect i ve Col l ect i ve el evat or unt i l t he out - of - ser vi ce car i s r et ur ned t o t he syst em.

][ 2. 2. 4 Gr oup Aut omat i c Oper at i on

NOTE: Choose f or t hr ee or mor e el evat or s t hat ser ve

SECTI ON 14 24 13 Page 14 t he same el evat or l obby.

Pr ovi de Gr oup Aut omat i c Oper at i on. I f a car i s t aken out of ser vi ce, or f ai l s t o r espond t o a l andi ng cal l wi t hi n a pr edet er mi ned adj ust abl e t i me l i mi t of appr oxi mat el y 40 t o 180 seconds, t r ansf er cal l s t o anot her car unt i l out - of - ser vi ce car i s r et ur ned t o t he syst em.

] 2. 3 SPECI AL OPERATI ON AND CONTROL

Pr ovi de t he f ol l owi ng speci al oper at i ons and cont r ol syst ems.

2. 3. 1 Keys f or El evat or Key Swi t ches

Pr ovi de a mi ni mum of t wel ve keys per uni que cyl i nder used on al l key swi t ches f or a s i ngl e el evat or . I f t her e i s mor e t han one el evat or , addi t i onal keys wi l l not be r equi r ed unl ess t her e ar e addi t i onal uni que l ock cyl i nder s. Pr ovi de keys wi t h br ass or f i ber gl ass t ags mar ked " PROPERTY OF THE U. S. GOVERNMENT" on one si de wi t h f unct i on of key or appr oved code number on t he ot her s i de.

2. 3. 2 Fi r ef i ght er s ' Emer gency Oper at i on ( FEO)

NOTE: Coor di nat e FEO Desi gnat ed Landi ng wi t h Fi r e Pr ot ect i on Desi gner .

Pr ovi de FEO equi pment and si gnal i ng devi ces. The desi gnat ed l evel f or t he FEO Phase I key oper at ed swi t ch i s t he [ gr ound] [ _____] f l oor . I n t he FEO Phase I f i x t ur e, pr ovi de FEO Oper at i ng I nst r uct i ons.

2. 3. 2. 1 Fi r ef i ght er s ' Emer gency Oper at i on ( FEO) Key Box

Pr ovi de f l ush mount ed, l ocki ng, FEO Key Box of a mi ni mum si ze of 127 mm W by 229 mm H by 38 mm D 5 i nch W by 9 i nch H by 1. 5 i nch D. I nst al l at a hei ght of 183 cm 6 f eet above f l oor l evel and di r ect l y above t he FEO Phase I key swi t ch. Pr ovi de box equi pped wi t h l ock t hat uses t he FEO K1 key.

2. 3. 3 Hoi st way Access Oper at i on

Pr ovi de hoi st way access oper at i on wi t h swi t ches at t op and bot t om t er mi nal l andi ngs. Locat e swi t ch 183 cm 6 f eet above f l oor l evel , wi t hi n 305 mm 12 i nches of el evat or hoi st way ent r ance f r ame or wi t h t he f er r ul e exposed when l ocat ed i n t he el evat or ent r ance f r ame.

2. 3. 4 I n- Car I nspect i on Oper at i on

Pr ovi de I n- Car I nspect i on Oper at i on.

2. 3. 5 I ndependent Ser v i ce

Pr ovi de exposed key- oper at ed swi t ch i n car oper at i ng panel t o enabl e i ndependent ser v i ce and si mul t aneousl y di sabl e i n- car s i gnal s and l andi ng- cal l r esponses. Pr ovi de i ndi cat or l i ght s t hat aut omat i cal l y i l l umi nat e dur i ng i ndependent ser vi ce. For dupl ex or gr oup oper at i on, i f one car i s r emoved f r om gr oup anot her car wi l l r espond t o i t s hal l cal l s .

SECTI ON 14 24 13 Page 15

2. 3. 6 Sel ect i ve Door Oper at i on

For el evat or wi t h one or mor e r ear openi ngs at same l evel as f r ont openi ng, pr ovi de f ul l - sel ect i ve oper at i on wi t h car and door oper at i ng but t ons c l ear l y mar ked f or f r ont and r ear openi ngs, f r ont and r ear car but t on f or each such f l oor , and f r ont and r ear " DOOR OPEN" and " DOOR CLOSE" but t ons.

Onl y door f or whi ch t he but t on was oper at ed opens or c l oses.

[ 2. 3. 7 El evat or Emer gency Power Oper at i on

NOTE: El ect r i cal desi gn shal l i dent i f y t he el evat or s t o be connect ed t o t he bui l di ng emer gency power syst em. I dent i f y and def i ne t he compl et e emer gency power syst em f or al l el evat or s. When usi ng t he 2nd br acket ed opt i on i n ei t her of t he next t wo subpar agr aphs, edi t as r equi r ed f or pr oj ect - speci f i c r equi r ement s.

For any el evat or t hat i s not i ncl uded i n t he bui l di ng emer gency power oper at i on, ut i l i ze par agr aph ELEVATOR AUXI LI ARY POWER OPERATI NG SYSTEM.

Pr ovi de el evat or emer gency power oper at i on f or [ al l el evat or s] [ el evat or 1, 2, 3. . . ] . Coor di nat e power suppl y and cont r ol wi r i ng t o accompl i sh i ni t i at i on and oper at i on of el evat or s on emer gency power .

][ 2. 3. 8 El evat or Auxi l i ar y Power Oper at i ng Syst em

Pr ovi de el evat or emer gency auxi l i ar y power oper at i ng syst em f or [ al l el evat or s] [ el evat or 1, 2, 3. . . ] .

] 2. 4 ELEVATOR DRI VE SYSTEM

Pr ovi de hydr aul i c el evat or dr i ve syst em, i ncl udi ng pump uni t , pi pi ng, cyl i nder / pl unger assembl y, and associ at ed equi pment , whi ch wi l l oper at e at a maxi mum wor ki ng pr essur e of 3447 kPag 500 psi or l ess. Pr ovi de compl et e el evat or syst em t hat meet s or exceeds t he NEII-1 Ri de Qual i t y St andar d, i ncl udi ng el evat or r i de qual i t y and noi se l evel s i n car and i n el evat or machi ne r oom and machi ner y space.

2. 4. 1 Hydr aul i c Pump Uni t

Pr ovi de sel f - cont ai ned pump uni t , i ncl udi ng oi l - hydr aul i c el evat or pump, el ect r i c mot or , suct i on- l i ne oi l s t r ai ner , and st r uct ur al st eel out er base wi t h t ank suppor t s and i sol at i on pads. Pr ovi de oi l t ank capaci t y f or f ul l pl unger di spl acement pl us at l east 38 l i t er s 10 gal l ons. Pr ovi de means t o mai nt ai n oi l t emper at ur e bet ween 38 and 54 degr ees C 100 and 130 degr ees F r egar dl ess of ambi ent t emper at ur e. Li mi t acoust i c out put i n el evat or machi ne r oom and machi ner y space t o 80 dbA.

2. 4. 1. 1 Pump Mot or

Pr ovi de i nt er mi t t ent - dut y pump mot or r at ed at 120 st ar t s/ hour . Pr ovi de mot or t hat i s s i zed so t hat t he mot or amper age does not exceed t he mot or dat a t ag amper age i n any oper at i ng condi t i on, excl usi ve of accel er at i on and decel er at i on. Pr ovi de mi ni mum of one mega ohm i nsul at i on r esi st ance bet ween conduct or s and mot or f r ame. Pr ovi de mot or and pump namepl at e and

SECTI ON 14 24 13 Page 16 dat a t ags per manent l y mount ed on t he out s i de of t he pump uni t f r ame, wi t h al l dat a v i ewabl e wi t hout t he use of mi r r or s or ot her t ool s.

2. 4. 2 Hydr aul i c Cont r ol s and Equi pment

Pr ovi de cont r ol val ve, over speed saf et y val ve, bl owout - pr oof muf f l er , and hydr aul i c pump di schar ge st r ai ner i n t he hydr aul i c oi l suppl y l i ne.

Pr ovi de t wo 1/ 4 t ur n, bal l val ve t ype manual shut of f val ves. Pr ovi de one i n t he el evat or hoi st way pi t and one i n t he el evat or machi ne r oom or machi ner y space.

2. 4. 2. 1 Hydr aul i c Cont r ol Val ve

Pr ovi de const ant - vel oci t y, down- speed r egul at ed, cont r ol val ve. Down- speed r egul at ed cont r ol val ve al l ows t he car t o t r avel at t he same speed i n t he down di r ect i on, r egar dl ess of t he l oad on t he el evat or . I n addi t i on, t he hydr aul i c cont r ol val ve must have bui l t - i n adj ust ment capabi l i t y t o oper at e t he el evat or at 140 per cent of r at ed speed t o f aci l i t at e per i odi c t est i ng of t he over speed saf et y val ve.

2. 4. 2. 2 Hydr aul i c Over speed Saf et y Val ve

Pr ovi de over speed saf et y val ve i n hydr aul i c oi l suppl y l i ne, di r ect l y adj acent t o t he hydr aul i c cyl i nder . Pr ovi de t hr eaded pi pe connect i ons bet ween t he hydr aul i c cyl i nder and t he over speed val ve. Pr ovi de val ve equi pped wi t h manuf act ur er ' s manual shut of f f eat ur e. Over speed val ve must not be equi pped wi t h a manual or aut omat i c l ower i ng f eat ur e. Pr ovi de adj ust abl e val ve wi t h means t o seal adj ust ment af t er i nspect i on and t est i ng by cer t i f i ed el evat or i nspect or .

2. 4. 3 Hydr aul i c Pi pi ng and Accessor i es

NOTE: Ret ai n br acket ed sent ence f or i n- gr ound di r ect pl unger t ype el evat or s.

Provide ASTM A53/ A53M or ASTM A106/ A106M, Schedul e 80, bl ack st eel pi pi ng with ASME B16. 9 or ASME B16. 11 f i t t i ngs f or suppl y pi pi ng. Ext end schedul e 80 pi pi ng f r om t he pump cont r ol val ve body, i nsi de t he pump uni t , t o t he hydr aul i c cyl i nder i n t he hoi st way. Pr ovi de wel ded or t hr eaded f or ged pi pe f i t t i ngs f or al l f i t t i ngs and component s of t he hydr aul i c oi l suppl y l i ne.

[ For i n- gr ound di r ect pl unger cyl i nder s, pr ovi de di el ect r i c uni on or i sol at i on coupl i ngs at each end of t he hydr aul i c oi l suppl y l i ne. ] Pr ovi de hanger s or suppor t s f or al l pi pi ng and component s.

2. 4. 3. 1 Cont ai nment of Hydr aul i c Oi l Suppl y Li ne

Pr ot ect al l por t i ons of hydr aul i c oi l suppl y l i ne t hat ar e i nst al l ed bel ow gr ound, i ncl udi ng por t i ons encapsul at ed i n concr et e or cover ed by const r uct i on, wi t h cont i nuous, Schedul e 80, PVC. I nsi de di amet er of PVC must be 76 mm 3 i nches l ar ger t han t he out s i de di amet er of t he hydr aul i c oi l suppl y l i ne pi pe and coupl i ngs.

2. 4. 4 Hydr aul i c El evat or Type

NOTE: Use of a hol el ess t ype el evat or wi t h a non- t el escopi ng j ack wi l l be l i mi t ed t o a maxi mum

SECTI ON 14 24 13 Page 17 t r avel di st ance of 12 f t - 8 i n.

Pr ovi de a [ i n- gr ound di r ect pl unger ] [ hol el ess] di r ect pl unger t ype hydr aul i c el evat or . El evat or wi t h t el escopi c or i nver t ed cyl i nder - pl unger s ar e not accept abl e and may not be used. Rope hydr aul i c el evat or desi gn i s not accept abl e and may not be used.

2. 4. 4. 1 Cyl i nder - Pl unger ( Jack) Uni t

Pr ovi de a s i ngl e- st age pl unger of seaml ess st eel const r uct i on. Pr ovi de cyl i nder wi t h sel f - st abi l i z i ng mount t hat wi l l suppor t and hol d cyl i nder pl umb wi t hout t he need f or st abi l i zat i on means at t he bot t om of t he cyl i nder . Pr ovi de a t hr eaded, 6 mm 1/ 4 i nch bl eeder val ve at t he t op of t he cyl i nder , j ust bel ow packi ng gl and.

[ 2. 4. 5 Cyl i nder Wel l Syst em

NOTE: Ret ai n t hi s par agr aph and associ at ed subpar agr aphs f or i n- gr ound di r ect pl unger t ype el evat or s onl y.

For di r ect pl unger , i n- gr ound t ype hydr aul i c el evat or , pr ovi de a dr y, seal ed cyl i nder wel l syst em.

2. 4. 5. 1 Wel l Casi ng

Locat e and dr i l l wel l f or t he cyl i nder wel l syst em. Li ne wel l wi t h st eel casi ng, mi ni mum 6 mm 1/ 4 i nch wal l wi t h wel ded 13 mm 1/ 2 i nch st eel bot t om. Set casi ng pl umb.

2. 4. 5. 2 PVC or HDPE Li ner

Pr ovi de Schedul e 80 PVC or HDPE l i ner wi t h bot t om cap and coupl i ngs; j oi nt s seal ed wat er t i ght usi ng pi pe manuf act ur er ' s r ecommended adhesi ve or heat wel di ng met hods. Pr ovi de l i ner i nsi de di amet er not l ess t han 76 mm 3 i nches l ar ger t han el evat or cyl i nder maxi mum out si de di amet er . Li ner may be pr ovi ded as a cy l i nder manuf act ur e' s appl i ed l i ner or as a separ at e component . For separ at e l i ner , set l i ner pl umb i n wel l casi ng, l ocat ed f or cyl i nder i nst al l at i on. Pr ovi de dr y, sal t - f r ee sand bel ow and ar ound l i ner t o t op of wel l casi ng.

2. 4. 5. 3 Cyl i nder I nst al l at i on

Remove al l moi st ur e f r om i nsi de of l i ner . I nst al l cy l i nder pl umb, i nsi de l i ner . Pr ovi de a 6 mm 1/ 4 i nch copper evacuat i on t ube i nsi de t he l i ner .

The bot t om of t he evacuat i on t ube must be wi t hi n 152 mm 6 i nch of t he bot t om of t he l i ner . Top of evacuat i on t ube must ext end at l east 152 mm 6 i nch above pi t f l oor . Pr ovi de t op of t est t ube wi t h r emovabl e cap t o excl ude f or ei gn mat t er . Pr ovi de ai r i nl et pr essur e f i t t i ng i n t op of l i ner and accessi bl e i n pi t , f or per f or mance of ai r pr essur e t est . Secur e Li ner / Cyl i nder Assembl y as r ecommended by cyl i nder manuf act ur er .

2. 4. 5. 4 Cyl i nder Li ner Moi st ur e Sensor Syst em

Pr ovi de moi st ur e and oi l sensor s i nsi de t he cyl i nder l i ner f or det ect i on of oi l and wat er at t he bot t om of t he cyl i nder l i ner . Pr ovi de sensor

SECTI ON 14 24 13 Page 18 moni t or i ng syst em t hat wi l l act uat e audi bl e and vi sual al ar ms and i dent i f y t he pr esence of wat er and i dent i f y t he pr esence of oi l i nsi de t he l i ner .

2. 4. 5. 5 Seal Top of Wel l Casi ng

Upon successf ul t est and cer t i f i cat i on of Li ner / Cyl i nder assembl y, seal gap bet ween st eel wel l casi ng and l i ner wi t h f oam i nser t st r ong enough t o r et ai n and suppor t f i nal gr out i ng. Pr ovi de 21 MPa 3000 psi gr out t o a mi ni mum of 102 mm 4 i nch t hi ckness and l evel t op of f i nal gr out i ng wi t h pi t floor.

] 2. 5 CONTROL EQUI PMENT

Encl ose al l el evat or cont r ol equi pment i n f act or y- pr i med and baked- enamel coat ed sheet - met al cabi net s wi t h vent i l at i on l ouver s and r emovabl e or hi nged door s. Mount cabi net s at a hei ght of 254 mm 10 i nches above machi ne r oom or cont r ol r oom f i ni sh f l oor .

2. 5. 1 Mot or Cont r ol Equi pment

Pr ovi de el evat or mot or cont r ol wi t h el ect r oni c, sof t - st ar t mot or st ar t er .

2. 5. 2 El evat or Mi cr opr ocessor Cont r ol l er

For each i ndi v i dual el evat or cont r ol l er , and f or each gr oup cont r ol l er , pr ovi de a mi cr opr ocessor cont r ol l er t hat compl i es wi t h t he f ol l owi ng par agr aphs. Pr ovi de cont r ol l er ( s) package t hat i ncl udes al l har dwar e and sof t war e r equi r ed f or t he i nst al l at i on, mai nt enance, and ser vi ce of t he el evat or , i n i t s ' ent i r et y. Pr ovi de ver i f i cat i on of t echni cal suppor t ser vi ce t hat t he cont r ol l er manuf act ur er pr ovi des t o any l i censed el evat or i nst al l at i on, ser vi ce, and mai nt enance company.

Pr ovi de an el evat or cont r ol l er f r om a manuf act ur er t hat pr ovi des compr ehensi ve f act or y t r ai ni ng t o i ncl ude cont r ol l er i nst al l at i on, adj ust ment , ser v i ce, and mai nt enance. The t r ai ni ng must be i dent i f i ed as avai l abl e t o any l i censed el evat or cont r act or . Pr ovi de ver i f i cat i on of an est abl i shed and document ed t r ai ni ng schedul e, wi t h pr i c i ng, f or f act or y t r ai ni ng c l asses t hat manuf act ur er has pr ovi ded f or a mi ni mum per i od of one year pr i or t o cont r act awar d dat e.

The el evat or cont r ol l er must be i dent i f i ed as avai l abl e f or pur chase and i nst al l at i on by any l i censed el evat or cont r act or . Al l component s, par t s, di agnost i c t ool s, and sof t war e must be avai l abl e f or pur chase and i nst al l at i on and use by any l i censed el evat or cont r act or ; " exchange- onl y" pr ovi s i ons f or t he pur chase of spar e par t s ar e not accept abl e. The el evat or cont r ol l er manuf act ur er must publ i sh an i ndust r y compet i t i ve pr i ce l i s t i ng f or al l cont r ol l er par t s, di agnost i c t ool s, and sof t war e.

Pr ovi de ver i f i cat i on of t el ephone and i nt er net based t echni cal suppor t ser vi ce t hat t he el evat or cont r ol l er manuf act ur er pr ovi des t o any l i censed el evat or i nst al l at i on, ser vi ce, and mai nt enance company at an i ndust r y compet i t i ve pr i ce. The ser vi ce must i ncl ude l i ve t el ephone based t echni cal suppor t f or i nst al l at i on, adj ust ment , mai nt enance, and t r oubl eshoot i ng of t he el evat or cont r ol l er and r el at ed el evat or component s. The ser vi ce must be avai l abl e dur i ng st andar d wor ki ng hour s.

Pr ovi de an el evat or cont r ol l er t hat i s desi gned t o aut omat i cal l y r eest abl i sh nor mal el evat or oper at i on f ol l owi ng any t empor ar y l oss of power , r egar dl ess of dur at i on.

SECTI ON 14 24 13 Page 19

2. 5. 2. 1 El evat or Cont r ol l er I nt er f ace Cabi net

For each i ndi v i dual el evat or mi cr opr ocessor cont r ol l er , pr ovi de a separ at e el evat or cont r ol cabi net wi t h an i nt egr at ed human i nt er f ace syst em. For gr oup el evat or i nst al l at i ons, a s i ngl e cabi net and i nt er f ace syst em wi t h f ul l access t o each el evat or cont r ol l er may be ut i l i zed. The separ at e cont r ol l er i nt er f ace cabi net must be suppl i ed by t he el evat or cont r ol l er manuf act ur er and i ncl ude a mi ni mum 305 mm 12 i nch wi de keyboar d and a mi ni mum 254 mm 10 i nch moni t or . The el evat or cont r ol l er i nt er f ace cabi net must compl y wi t h ar c- f l ash pr ot ect i on r equi r ement s of NFPA 70E and

UFC 3- 560- 01.

2. 5. 2. 1. 1 El evat or Mi cr opr ocessor Human I nt er f ace

The i nt er f ace syst em must pr ovi de compl et e el evat or cont r ol l er i nt er f ace capabi l i t y and must i ncl ude t he el evat or cont r ol l er manuf act ur er ' s compr ehensi ve package of i nst al l at i on and di agnost i c sof t war e. The mi cr opr ocessor i nt er f ace syst em must pr ovi de unr est r i c t ed access t o al l par amet er s, al l l evel s of adj ust ment , and al l f l ags necessar y f or i nst al l at i on, adj ust ment , mai nt enance, and t r oubl eshoot i ng of each el evat or and f or t he el evat or gr oup. Al l sof t war e pr ogr ammi ng must be st or ed i n non- vol at i l e memor y. The el evat or cont r ol l er f aul t l og must pr ovi de non- vol at i l e memor y f aul t l og st or age of al l f aul t s, t r oubl e cal l s , and f aul t hi st or y f or a mi ni mum of one year and t he abi l i t y t o downl oad or pr i nt t he f aul t l og. The cont r ol l er i nt er f ace must al so pr ovi de t he capabi l i t y t o di spl ay and di agnose t r oubl e cal l s , f aul t s, and shut downs.

Expi r i ng sof t war e, degr adi ng oper at i on, and " key" access cont r ol s ar e not acceptable.

2. 5. 2. 2 Sof t war e and Document…

This is the start of the file's text. The full file is on GovTribe.