BID SCHEDULE - BASE YR

ITEM #SCOPE OF WORK DESCRIPTIONSPEC./DTL. REFERENCEUNITEST. QUAN.UNIT
COSTTOTAL
Division 02 - Site Construction
Section 02 41 00 - Selective Demolition
A0001Remove and dispose of built-up asphalt roofing with aggregate surfacing down to the roof deck surface. Include membrane, penetration and wall flashings, cants, crickets and all fasteners. Estimate minimum 1-1/2" to maximum 6" insulation. Minimum 100 SF.SPEC: 02 41 00SF15,000$0.00
A0002Remove and dispose of built-up coal tar pitch roofing with aggregate surfacing down to the roof deck surface. Include membrane, penetration and wall flashings, cants, crickets and all fasteners. Estimate minimum 1-1/2" to maximum 6" insulation. Minimum 100 SF.SPEC: 02 41 00SF5,000$0.00
A0003Remove and dispose of built-up smooth surfaced asphalt roofing down to the roof deck surface. Include membrane, penetration and wall flashings, cants, crickets and all fasteners. Estimate minimum 1-1/2" to maximum 6" insulation. Minimum 100 SF.SPEC: 02 41 00SF15,000$0.00
A0004Remove and dispose of modified bitumen roofing with granular surface cap sheet down to the roof deck. Include membrane, penetration and wall flashings, cants, crickets and all fasteners. Estimate minimum 1-1/2" to maximum 6" insulation. Minimum 100 SF.SPEC: 02 41 00SF15,000$0.00
A0005Remove and dispose of fully adhered single ply roofing (PVC, EPDM, PIB, etc.) down to the roof deck surface. Include membrane, penetration and wall flashings, cants, crickets and all fasteners. Estimate minimum 1-1/2" to maximum 6" insulation. Minimum 100 SF.SPEC: 02 41 00SF2,000$0.00
A0006Remove and dispose of mechanically fastened single ply roofing (PVC, EPDM, PIB, etc.) down to the roof deck surface. Include membrane, penetration and wall flashings, cants, crickets and all fasteners. Estimate minimum 1-1/2" to maximum 6" insulation. Minimum 100 SF.SPEC: 02 41 00SF3,000$0.00
A0007Remove and dispose of built-up asphalt roofing with aggregate surfacing. Include membrane, penetration & wall flashings & membrane fasteners. DO NOT include insulation, crickets and insulation fasteners. Minimum 100 SF.SPEC: 02 41 00SF3,000$0.00
A0008Remove and dispose of built-up coal tar pitch roofing with aggregate surfacing. Include membrane, penetration and wall flashings and membrane fasteners. DO NOT include insulation, crickets, cants and insulation fasteners. Minimum 100 SF.SPEC: 02 41 00SF500$0.00
A0009Remove and dispose of built-up smooth surfaced asphalt roofing. Include membrane, penetration & wall flashings and membrane fasteners. DO NOT include insulation, crickets, cants and insulation fasteners. Minimum 100 SF.SPEC: 02 41 00SF3,000$0.00
A0010Remove and dispose of modified bitumen roofing with cap sheet. Include membrane, penetration & wall flashings and membrane fasteners. DO NOT include insulation, crickets, cants and insulation fasteners . Minimum 100 SF.SPEC: 02 41 00SF2,000$0.00
A0011Remove and dispose of aggregate ballast. Include spudding-back and vacuuming loose aggregate from entire roof surface. Minimum 100 SF.SPEC: 02 41 00SF600$0.00
A0012Remove and dispose of additional insulation exceeding 6" from entire roof surface. Average Thickness Increase 1"; Minimum 100 SF.SPEC: 02 41 00SF1,600$0.00
A0013Remove and dispose of spray polyurethane foam roofing materials from entire roof deck surface. Average 4" thickness; Minimum 100 SF.SPEC: 02 41 00SF100$0.00
A0014Remove and dispose of fully adhered single ply roofing (PVC, EPDM, PIB, etc.). Include membrane, penetration & wall flashings. DO NOT include insulation, crickets, cants and insulation fasteners. Minimum 100 SF.SPEC: 02 41 00SF500$0.00
A0015Remove and dispose of mechanically fastened single ply roofing (PVC, EPDM, PIB, etc.) down to the deck. Include membrane, penetration & wall flashings and membrane fasteners. DO NOT include insulation, crickets and insulation fasteners. Minimum 100 SF.SPEC: 02 41 00SF500$0.00
A0016Remove and dispose of metal roof panels w/exposed fasteners including edge and rake flashings to the structural sub-framing or decking. Include all clips, anchors, fasteners and accessories. Minimum 100 SF.SPEC: 02 41 00SF2,000$0.00
A0017Remove and dispose of metal roof panels w/concealed fasteners including edge and rake flashings to the structural sub-framing or decking. Include all clips, anchors, fasteners and accessories . Minimum 100 SF.SPEC: 02 41 00SF200$0.00
A0018Remove and dispose of abandon equipment capped curbed and/or opening. Including sheet metal flashing and trim, wood or metal curbing, cants, cricket and flashing. Minimum (4) Square Feet.SPEC: 02 41 00SF16$0.00
A0019Remove and re-install aggregate ballast from asphalt or coal-tar pitch roofing. Minimum 100 SF.SPEC: 02 41 00SF200$0.00
A0020Provide for the removal and disposal of termination sheet metal flashing items including cap flashing, expansion joint covers, parapet coping caps. Minimum (10) Linear Feet.SPEC: 02 41 00LF6,730$0.00
A0021Provide for the removal and disposal of sheet metal items including gravel stop, drip edge, etc… Minimum (10) Linear Feet.SPEC: 02 41 00LF6,730$0.00
A0022Provide for the removal and disposal of termination sheet metal items including counter flashings, skirt flashings, reglets and termination bars at walls or curbs. Minimum (10) Linear Feet.SPEC: 02 41 00LF560$0.00
A0023Remove and dispose of sheet metal pitch pans including non-shrink grout and non-sag pourable asphaltic sealer.SPEC: 02 41 00EA12$0.00
A0024Remove and dispose of sheet metal gutter assembly including anchors, hangars, straps, and fasteners.SPEC: 02 41 00LF2,000$0.00
A0025Remove and dispose of sheet metal downspout assembly including anchors, hangars, straps, and fasteners.SPEC: 02 41 00LF3,000$0.00
A0026Remove and dispose of sheet metal scupper assembly including anchors, hangars, straps, and fasteners.SPEC: 02 41 00EA12$0.00
A0027Remove and dispose of sheet metal conductor box and associated flashings at scupper locations including anchors, hangars, straps, and fasteners.SPEC: 02 41 00EA8$0.00
A0028Remove and dispose of wood blocking including anchors, hangars, straps, and fasteners.SPEC: 02 41 00BF500$0.00
A0029Remove and dispose of plywood including anchors, straps, and fasteners.SPEC: 02 41 00SF600$0.00
A0030Remove and dispose of self-adhered modified bituminous membrane from surfaces. Minimum 100 SF.SPEC: 02 41 00SF100$0.00
A0031Remove and dispose of cementitious wood fiber roof deck/form board (Tectum). Average Thickness 2-1/2"SPEC: 02 41 00SF100$0.00
A0032Remove and dispose damaged, deteriorated and/or heavily corroded steel bulb tee supports to perform associated roof work. Minimum 6 LF.SPEC: 02 41 00LF60$0.00
A0033Remove, protect and re-install corrugated fiberglass wall panels with exposed fasteners to perform associated roof work. Minimum 50 SF.SPEC: 02 41 00SF100$0.00
A0034Remove and dispose of deteriorated corrugated fiberglass wall panels. Minimum 50 SF.SPEC: 02 41 00SF100$0.00
A0035Remove and dispose of deteriorated corrugated fiberglass roof panels. Minimum 50 SF.SPEC: 02 41 00SF100$0.00
A0036Remove, protect and re-install corrugated or fluted metal wall panels with exposed fasteners to perform associated roof work. Minimum 50 SF.SPEC: 02 41 00SF100$0.00
A0037Remove and dispose of deteriorated corrugated or fluted metal roof and/or wall panels w/exposed fasteners and flashings down to the structural support members. Minimum 50 SF.SPEC: 02 41 00SF200$0.00
A0038Remove and dispose of deteriorated metal roof and/or wall panels w/concealed fasteners and flashings down to the structural supports. Include all clips, anchors and fasteners. Minimum 50 SF.SPEC: 02 41 00SF200$0.00
A0039Remove and dispose of metal hat channels, purlins, girts and other supports associated with metal roof and wall panels. Include all associated clips, anchors and fasteners. Minimum 100 LF.SPEC: 02 41 00LF100$0.00
A0040Remove and dispose of abandon and/or deteriorated mechanical equipment piping from the roof. Including but not limited to, fittings, supports, straps, etc... Minimum 10 LFSPEC: 02 41 00LF100$0.00
A0041Provide for the removal and disposal of debris and abandon or deteriorated equipment and/or structures from the roof area. Minimum 1/2 Ton.SPEC: 02 41 00Ton5$0.00
A0042Disassemble and salvage miscellaneous metals and structural components including joist, girders, angles, plates, doors, frames, gratings, ladders, railings, etc. Minimum 100 lbs.SPEC: 02 41 00100 Lbs10$0.00
A0043Saw cut, remove and dispose of masonry. Minimum 10 CFSPEC: 02 41 00CF10$0.00
A0044Saw cut, remove and dispose of concrete. Minimum 10 CFSPEC: 02 41 00CF10$0.00
Section 02 42 91 -Removal and Salvage of Historic Building Materials
A0045Remove, salvage, protect, turn-over to government historic architectural elements including brick, cast stone, clay roof tiles and trim elements, metalwork, ladders, stairs, handrails, gratings and walkways. Minimum 100 lbs.SPEC: 02 42 91100 Lbs10$0.00
Section 02 82 13 - Asbestos Abatement
A0046Remove and dispose of CLASS I asbestos containing roof materials (ACRM) roof membrane. Minimum 10-SF.SPEC: 02 82 13SF500$0.00
A0047Remove and dispose of CLASS II asbestos containing roof materials (ACRM) roof membrane. Minimum 10-SF.SPEC: 02 82 13SF100$0.00
A0048Remove, protect and re-install corrugated asbestos wall panels (Transite) w/exposed fasteners. Minimum 20 SF.SPEC: 02 82 13SF100$0.00
A0049Remove and dispose of corrugated asbestos wall panels (Transite). Minimum 20 SF.SPEC: 02 82 13SF100$0.00
A0050Remove and dispose of cementitious asbestos fiber roof deck/form board (Transite).SPEC: 02 82 13SF50$0.00
Section 02 83 13 - Lead in Construction
A0051Remove and Dispose of Lead Based Coatings from Steel Substrate.SPEC: 02 83 13SF10$0.00
A0052Remove and Dispose of Lead Based Coatings from Concrete / CMU Substrate.SPEC: 02 83 13SF10$0.00
A0053Remove and Dispose of Lead Based Coatings from Wood Substrate.SPEC: 02 83 13SF10$0.00
Division 03 - Concrete
Section 03 51 00 - Roof Deck Replacement, Cast-in-Place Gypsum Concrete
A0054Remove, dispose of and repair deteriorated surfaces of gypsum concrete with appropriate patching compound. Approximate size of each patch – 1 inch deep, 10-Square Feet.SPEC: 03 51 00CF40$0.00
A0055Remove, dispose of and replace areas of deteriorated or damaged gypsum concrete roof deck down to the form board or metal deck. Install gypsum concrete in accordance with manufacturer's written instructions. Average roof deck depth 4”.SPEC: 03 51 00CF40$0.00
A0056Remove, dispose of and replace areas of deteriorated or damaged woven wire reinforcement. Install woven wire reinforcement in accordance with manufacturer's written instructions. Average area of repair (12) SF.SPEC: 03 51 00SF100$0.00
A0057Furnish and install thick cementitious wood fiber deck panel (Tectum) in accordance with manufacturer's written instructions. Minimum (12) SFSPEC: 03 51 00SF12$0.00
A0058Remove, dispose and replace damaged, deteriorated or heavily corroded steel bulb tee supports. Weld new bulb tee sections in place. Minimum (6) LF.SPEC: 03 51 00LF18$0.00
Section 03 52 00 - Roof Decking, Cast-in-Place Low Density Concrete
A0059Remove, dispose of and repair deteriorated surfaces of lightweight concrete with appropriate patching compound. Approximate size of each patch – 1 inch deep, 10-Square Feet.SPEC: 03 52 00CF40$0.00
A0060Remove, dispose of and replace areas of deteriorated or damaged lightweight insulating concrete down to the form board or deck. Average depth 4".SPEC: 03 52 00CF40$0.00
A0061Deliver and place insulating lightweight concrete to entire roof; 2" minimum thickness, provide positive slope for drainage.SPEC: 03 52 00CF100$0.00
Division 04 - Masonry
Section 04 01 20 - Maintenance of Unit Masonry
A0062Clean existing masonry surface with acid and/or solvent. Perform work in conformance with manufacturer's written instructions, guidelines and standards including materials, procedures, and requirements. Minimum 50 SF.SPEC: 04 01 20SF50$0.00
A0063Clean existing masonry surface with water blasting. Perform work in conformance manufacturer's written instructions, guidelines and standards including materials, procedures, and requirements. Minimum 200 SF.SPEC: 04 01 20SF200$0.00
A0064Clean existing masonry surface with steam blasting. Perform work in conformance with manufacturer's written instructions, guidelines and standards including materials, procedures, and requirements. Minimum 55 SF.SPEC: 04 01 20SF55$0.00
A0065Remove, dispose of and replace areas of deteriorated or damaged clay masonry units. Include re-grouting, tuck pointing. Perform work in conformance with manufacturer's written instructions, guidelines and standards including materials, procedures, and requirements. Minimum 30 SF.SPEC: 04 01 20SF30$0.00
A0066Remove, dispose of and replace areas of deteriorated or damaged concrete masonry units. Include re-grouting, tuck pointing. Perform work in conformance with manufacturer's written instructions, guidelines and standards including materials, procedures, and requirements. Minimum 30 SF.SPEC: 04 01 20SF30$0.00
A0067Cut-out, dispose of and re-point areas of deteriorated or damaged masonry joints. Include new masonry units, re-grouting, tuck pointing. Perform work in conformance manufacturer's written instructions, guidelines and standards including materials, procedures, and requirements. Minimum 30 SF.SPEC: 04 01 20SF30$0.00
Division 05 - Metals
Section 05 30 00 - Steel Decks
A0068Provide and install shop primed structural steel roof decking; including 1" to 1-5/8" deep flutes, 24 gauge. Include the installation of associated items, including panel edge closures and miscellaneous perimeter and wall items.SPEC: 05 30 00SF1,200$0.00
A0069Provide and install shop primed structural steel roof decking; including 1-5/8" to 2" deep flutes, 22 gauge. Include the installation of associated items, including panel edge closures and miscellaneous perimeter and wall items.SPEC: 05 30 00SF1,200$0.00
Section 05 40 00 - Cold-Formed Metal Framing
A0070Furnish and install non-load bearing cold-formed metal stud framing, 1-5/8" to 6", 24 gauge. Minimum 20 Linear Feet.SPEC: 05 40 00LF20$0.00
A0071Furnish and install non-load bearing cold-formed metal stud framing, 4" to 6", 20 gauge. Minimum 20 Linear Feet.SPEC: 05 40 00LF20$0.00
A0072Furnish and install load bearing cold-formed metal stud framing, 4" to 6", 18 gauge. Minimum 20 Linear Feet.SPEC: 05 40 00LF20$0.00
A0073Furnish and install cold-formed metal framing members, 18 gauge, which includes saddles, cant strips, curbs for scuttles and ventilators, and nailers attached at the tops of concrete or masonry curbs, expansion joints and roof edges. Minimum 20 Linear Feet.SPEC: 05 40 00LF100$0.00
A0074Furnish and install non-load bearing cold-formed metal stud framing, 4" to 6", 16 gauge. Minimum 20 Linear Feet.SPEC: 05 40 00LF20$0.00
A0075Furnish and install load bearing cold-formed metal parapet wall framing, 4" to 6", 18 gauge, 3'-0" high, 12" o.c. Minimum 20 Linear Feet.SPEC: 05 40 00LF20$0.00
A0076Furnish and install load bearing cold-formed metal soffit framing, 4" to 8", 18 gauge. Minimum 20 Linear Feet.SPEC: 05 40 00LF20$0.00
A0077Furnish and install load bearing cold-formed metal manufactured pre-engineered truss, 4" chords, 18 gauge, 16'-0" span.SPEC: 05 40 00EA1$0.00
A0078Furnish and install load bearing cold-formed metal manufactured pre-engineered truss, 6" chords, 18 gauge, 28'-0" to 40'-0" span.SPEC: 05 40 00EA1$0.00
A0079Provide and install retrofit sub-purlin and/or formed shaped framing system mechanically fastened to existing framing and/or substrate as per manufacturer’s requirements. Include all anchors, fasteners, clips, connectors and accessories . Minimum 16 gauge thickness. Do not include metal panel roofing. Minimum 100 LFSPEC: 05 40 00 paragraph 2.3LF1,000$0.00
Section 05 50 00 - Metal Fabrication
A0080Fabricate and install shop primed miscellaneous steel materials; including but not limited to, weld plates, angles for casting into concrete, anchor bolts, steel pipe sleeves, and wedge-type inserts to be cast into concrete or built into unit masonry, framing, supports and fabricated items for applications that are not specified in other specification sections.SPEC: 05 50 00LB50$0.00
Section 05 51 00 - Metal Stairs
A0081Fabricate and install industrial-type stair system, which includes but not limited to, steel grate treads and platforms, steel tube railings, guards attached to metal stairs and/or adjacent walls. Minimum 3'-0" Wide x 10'-0" Rise x 16'-0" Run.SPEC: 05 51 00Rise16$0.00
A0082Remove, dispose of and replace areas of deteriorated or damaged steel grate treads and platforms of the industrial-type stair system. Minimum 20 SF.SPEC: 05 51 00SF20$0.00
A0083Remove, dispose of and replace areas of deteriorated or damaged steel tube railings and/or guards attached to metal stairs and/or adjacent walls of the industrial-type stair system. Minimum 10 LF.SPEC: 05 51 00LF10$0.00
A0084Clean, prime, paint and finish areas of deteriorated existing steel grate treads and platforms of the industrial-type stair system. Perform work in conformance with manufacturer's written instructions and recommendations. Minimum 20 SF.SPEC: 05 51 00SF20$0.00
A0085Clean, prime, paint and finish areas of deteriorated existing steel tube railings and/or guards attached to metal stairs and/or adjacent walls of the industrial-type stair system. Perform work in conformance with manufacturer's written instructions and recommendations. Minimum 20 LF.SPEC: 05 51 00LF20$0.00
Section 05 51 33 - Metal Ladders
A0086Fabricate and install aluminum roof access ladder system, which includes but not limited to, side rails, rungs, mounting brackets, with cage and/or related safety rail system. Minimum 20 LF.SPEC: 05 51 33LF20$0.00
A0087Fabricate and install aluminum roof access ladder system, which includes but not limited to, side rails, rungs, mounting brackets, without cage and/or related safety rail system. Minimum 20 LF.SPEC: 05 51 33LF20$0.00
A0088Fabricate and install galvanized steel roof access ladder system, which includes but not limited to, side rails, rungs, mounting brackets, with cage and/or related safety rail system. Minimum 20 LF.SPEC: 05 51 33LF20$0.00
A0089Fabricate and install galvanized steel roof access ladder system, which includes but limited to, side rails, rungs, mounting brackets, without cage and/or related safety rail system. Minimum 20 LF.SPEC: 05 51 33LF20$0.00
A0090Fabricate and install aluminum ladder security door, 14 gauge aluminum sheet, able to withstand a 200-pound force applied at any point from any direction.SPEC: 05 51 33EA2$0.00
A0091Fabricate and install G-90 galvanized steel security door, 16 gauge steel sheet, powder coat finish, able to withstand a 200-pound force applied at any point from any direction.SPEC: 05 51 33EA2$0.00
A0092Fabricate and install G-90 galvanized steel security grill, 16 gauge steel with powder coat finish and 50% minimum open area, able to withstand a 200-pound force applied at any point from any direction.SPEC: 05 51 33EA2$0.00
A0093Remove, dispose of and replace areas of deteriorated or damaged roof access ladder system, which includes but not limited to, side rails, rungs, cage and/or mounting brackets. Minimum 10 LF.SPEC: 05 51 33LF10$0.00
A0094Clean, prime, paint and finish areas of deteriorated existing roof access ladder system, which includes but not limited to, side rails, rungs, cage and/or mounting brackets. Perform work in conformance with manufacturer's written instructions and recommendations. Minimum 20 LF.SPEC: 05 51 33LF20$0.00
Section 05 52 13 - Pipe and Tube Railings
A0095Fabricate and install a side or base mount aluminum pipe and/or tube guardrail system. Minimum 12 LF.SPEC: 05 52 13LF12$0.00
A0096Fabricate and install a side or base mount stainless steel pipe and/or tube guardrail system. Minimum 12 LF.SPEC: 05 52 13LF12$0.00
A0097Fabricate and install a side or base mount galvanized steel pipe and/or tube guardrail system. Minimum 12 LF.SPEC: 05 52 13LF12$0.00
A0098Remove and dispose of areas of deteriorated or damaged pipe and/or tube guardrail system. Minimum 20 LF.SPEC: 05 52 13LF20$0.00
A0099Clean, prime, paint and finish areas of deteriorated existing pipe and/or tube guardrail system. Perform work in conformance with manufacturer's written instructions and recommendations. Minimum 20 LF.SPEC: 05 52 13LF20$0.00
Section 05 53 00 - Metal Grating
A0100Fabricate and install aluminum grating for elevated platforms and walkways. Minimum 30 SF.SPEC: 05 53 00SF30$0.00
A0101Fabricate and install stainless steel grating for elevated platforms and walkways. Minimum 30 SF.SPEC: 05 53 00SF30$0.00
A0102Fabricate and install galvanized steel grating for elevated platforms and walkways. Minimum 30 SF.SPEC: 05 53 00SF30$0.00
A0103Remove and dispose of areas of deteriorated or damaged grating for elevated platforms and walkways. Minimum 15 SF.SPEC: 05 53 00SF15$0.00
A0104Clean, prime, paint and finish areas of deteriorated existing grating for elevated platforms and walkways. Perform work in conformance with manufacturer's written instructions and recommendations. Minimum 20 SF.SPEC: 05 53 00SF20$0.00
Division 06 - Wood and Plastics
Section 06 10 00 - Rough Carpentry
A0105Re-secure existing roof nailers to roof deck and/or substrate, which includes an average size of 6 inches wide by 4 inches thick. Minimum 100 Linear Feet.SPEC: 06 10 00LF200$0.00
A0106Furnish and install preservative-treated wood roof nailers, which includes wood saddles or crickets, cant strips, curbs for scuttles and ventilators, and wood nailers bolted to tops of concrete or masonry curbs and at expansion joints.SPEC: 06 10 00BF50$0.00
A0107Furnish and install preservative-treated wood roof nailers, which includes perimeter of roof, around openings through roof, and where roofs abut walls, curbs, and other vertical surfaces.SPEC: 06 10 00BF25$0.00
A0108Furnish and install roof framing lumber, which includes studs, plates, caps, collar beams, bucks, sleepers, nailing strips and sills.SPEC: 06 10 00 paragraph 2.1.2BF20$0.00
A0109Furnish and install 5/8" plywood wall sheathing.SPEC: 06 10 00 paragraph 2.2SF64$0.00
A0110Furnish and install 3/4" plywood roof sheathing.SPEC: 06 10 00 paragraph 2.2SF64$0.00
A0111Furnish and install roof decking, which includes decking 2 inches thick with single tongue and groove; V-jointed, matched and dressed and/or fabricated laminated lumber decking with interlocking tongue and groove joints.SPEC: 06 10 00 paragraph 2.3.1SF20$0.00
A0112Furnish and install fascia lumber, which includes 1X or 2X nominal thickness.SPEC: 06 10 00 paragraph 2.3.2BF10$0.00
Section 06 71 33 - Fiberglass Reinforced Plastic (FRP) Ladders
A0113Fabricate and install FRP ladder system, which includes but limited to, side rails, rungs, mounting brackets, with cage and related safety rail system. Minimum 20 LF.SPEC: 06 71 33EA1$0.00
A0114Fabricate and install FRP ladder system, which includes but limited to, side rails, rungs, mounting brackets, without cage and related safety rail system. Minimum 20 LF.SPEC: 06 71 33EA1$0.00
Section 06 73 01 - Fiberglass Reinforced Plastic (FRP) Grating
A0115Fabricate and install FRP grating for elevated platforms and walkways. Minimum 30 SF.SPEC: 06 73 01SF30$0.00
Section 06 82 14 - Fiberglass Reinforced Plastic (FRP) Pipe and Tube Railings
A0116Fabricate and install FRP pipe and/or tube side mounted guardrail system. Minimum 12 LF.SPEC: 06 82 14LF12$0.00
A0117Fabricate and install FRP pipe and/or tube base mounted guardrail system. Minimum 12 LF.SPEC: 06 82 14LF12$0.00
Division 07 - Thermal and Moisture Protection
Section 07 01 50.62 - Built-UP Asphalt Roofing Repairs
A0118Remove loose aggregate from aggregate-surfaced built-up bituminous roofing with a power broom. Discard aggregate ballast. Install (2) glass-fiber felts lapping each sheet (18) inches over preceding sheet. Embed glass-fiber felt in a solid mopping of hot roofing asphalt applied within equiviscous temperature range. Glaze-coat completed surface with hot roofing asphalt. Minimum 50 SF.SPEC: 07 01 50.62SF600$0.00
A0119Remove aggregate ballast from aggregate-surfaced built-up bituminous membrane. Store aggregate ballast for reuse. Install (2) glass-fiber felts lapping each sheet (18) inches over preceding sheet. Embed glass-fiber felt in a solid mopping of hot roofing asphalt applied within equiviscous temperature range. Install gravel surfacing in an asphalt flood coat over built-up roofing, utilizing Type 4 asphalt. Minimum 50 SF.SPEC: 07 01 50.62SF400$0.00
A0120Spud-back and vacuum the loose existing gravel from the entire roof surface. Remove loose aggregate from aggregate-surfaced built-up bituminous roofing with a power broom. Broom clean existing substrate. Verify that existing substrate is dry prior to proceeding. Remove materials that are wet or damp. Install recovery board by hot mopping or mechanically fasteners. Install (2) glass-fiber felts lapping each sheet (18) inches over preceding sheet. Embed glass-fiber felt in a solid mopping of hot roofing asphalt applied within equiviscous temperature range. Glaze-coat completed surface with hot roofing asphalt. Install gravel surfacing in an asphalt flood coat over built-up roofing. Minimum 50 SF.SPEC: 07 01 50.62SF400$0.00
A0121Remove blisters, ridges, buckles, roofing membrane fastener and other substrate irregularities projecting above the membrane from existing roofing membrane. Install 2-ply temporary asphalt built-up roofing with a flood coating of asphalt. All surfaces must be clean and dry. Minimum 50 SF.SPEC: 07 01 50.62SF800$0.00
A0122Remove and dispose existing concrete roof pavers from roofing membrane.SPEC: 07 01 50.62EA10$0.00
A0123Remove and replace existing concrete roof pavers.SPEC: 07 01 50.62EA10$0.00
A0124Furnish and install filler at pitch pan. Remove and dispose of deteriorated filler prior to topping off. Use grout filler and 1-Part self-leveling pourable sealer for slope of adequate moisture run-off.SPEC: 07 01 50.62 DWG 2.25EA20$0.00
A0125Remove, repair and replace areas of roofing membrane flashing irregularities from existing roofing flashings that inhibit Cold Fluid-Applied Aluminumized Elastomeric Coating System. Furnish and apply one coat of aluminumized elastomeric coating to surfaces of roof flashing membrane; 16 mil minimum total cured system thickness. Minimum 20 SF.SPEC: 07 01 50.62SF100$0.00
A0126Remove aggregate ballast from aggregate-surfaced built-up bituminous membrane. Store aggregate ballast for reuse. Install (2) glass-fiber felts lapping each sheet (18) inches over preceding sheet. Embed glass-fiber felt in a solid mopping of hot roofing asphalt applied within equiviscous temperature range. Install gravel surfacing in an asphalt flood coat over built-up roofing, utilizing Type 4 asphalt. Minimum 50 SF.SPEC: 07 01 50.62SF300$0.00
A0127Install 1/4" re-cover board over roof insulation and/or roofing membrane with long joints in continuous straight lines and end joints staggered between rows; mechanically fasten to the existing roof deck as per manufacturer’s requirements. Furnish and install (1) SBS 120 mil inter-ply sheet along with (1) SBS 160 mil granular cap sheet. Minimum 100 SF.SPEC: 07 01 50.62SF100$0.00
A0128Refurbish the existing roofing system with new Asphalt Compatible Roofing Emulsion System. Remove blisters, ridges, buckles, roofing membrane fastener projecting above the membrane and other substrate irregularities from existing roofing membrane that inhibit Asphalt compatible Roofing Emulsion System.SPEC: 07 01 50.62SF100$0.00
A0129Refurbish the existing roofing system with new Asphalt Compatible Roofing Emulsion System and Asphalt Patching Cement. The systems consist of spudding-back and vacuuming the loose existing gravel from the entire roof surface. Minimum 50 SF.SPEC: 07 01 50.62SF100$0.00
A0130Furnish and install standard 12" high, 4" I.D. relief vent to the substrate as per manufacturer’s requirements.SPEC: 07 01 50.62EA10$0.00
A0131Install 2-ply temporary asphalt built-up roofing with a flood coating of asphalt. Minimum 50 Square Feet.SPEC: 07 01 50.62SF100$0.00
A0132Replace roof edges flashing along with deteriorate wood nailer as required with asphalt base flashing material matching the existing membrane roofing system materials, stainless steel flashing material and pressure-treated wood as per manufacturer’s requirements. Average flashing width 18-inches. Minimum 20 Linear Feet.SPEC: 07 01 50.62 DWG 1.01LF100$0.00
A0133Replace base flashings around parapets, curbs and walls along with deteriorate wood nailer as required with asphalt base flashing material matching the existing membrane roofing system materials, stainless steel flashing material and pressure-treated wood as per manufacturer’s requirements. Furnish and install 2-ply modified bitumen flashings set in roof mastic. Average base flashing height 8-inches. Minimum 20 Linear Feet.SPEC: 07 01 50.62 DWG 1.02LF100$0.00
A0134Replace base flashings around parapets, curbs and walls along with deteriorate wood nailer as required with asphalt base flashing material matching the existing membrane roofing system materials, stainless steel flashing material and pressure-treated wood as per manufacturer’s requirements. Furnish and install 2-ply modified bitumen flashings set in roof mastic. Average base flashing height 24-inches. Minimum 20 Linear Feet.SPEC: 07 01 50.62 DWG 1.02LF100$0.00
Section 07 14 16 - Fluid-applied Waterproofing
A0135Furnish and install a three-stage, fabric reinforced, flexible acrylic coating, fluid applied in successive stages to form one continuous, seamless, watertight membrane as per manufacturer’s requirements; 25 mil minimum total cured system thickness. Minimum 1 square (SQ = 100 SF).SPEC: 07 14 16SF2,000$0.00
A0136Furnish and install a three-stage, fabric reinforced, flexible acrylic coating, fluid applied in successive stages to form one continuous, seamless, watertight membrane as per manufacturer’s requirements; 40 mil minimum total cured system thickness. Minimum 1 square (SQ = 100 SF).SPEC: 07 14 16SF2,000$0.00
A0137Furnish and install new foam roof insulation (i.e. PUF) materials matching the existing roofing system materials in areas which are to receive roof coatings to the manufacturer’s specified density. Clean and prepare surfaces to receive foam roof insulation materials by removing all existing loose and flaking materials. Minimum 20 SF.SPEC: 07 14 16SF20$0.00
A0138Clean rust and scale from metal surfaces of the existing roofing system in areas which are to receive roof coatings by abrasive cleaning disks and/or wire brushing, to the manufacturer’s specified conditions unless otherwise indicated. Minimum 10 SF.SPEC: 07 14 16SF10$0.00
A0139Remove, repair and replace areas of blisters, ridges, buckles, roofing membrane fastener projecting above the membrane and other substrate irregularities from existing roofing membrane that inhibit Cold Fluid-Applied Flexible Acrylic Roofing System. Minimum 10 SF.SPEC: 07 14 16SF10$0.00
Section 07 22 16.22 - Roof Board Insulation (Polyisocyanurate)
A0140Furnish and install vapor retarder to roof deck surface. Minimum 100 Square Feet.SPEC: 07 22 16.22 paragraph 2.4 and 2.7.1SF100$0.00
A0141Furnish and install 1-1/2-inch to 3-1/2-inch polyisocyanurate insulation board, mechanically fastened to the substrate as per manufacturer’s requirements. Minimum 100 Square Feet.SPEC: 07 22 16.22SF3,000$0.00
A0142Furnish and install 1-1/2-inch to 3-1/2-inch polyisocyanurate insulation board. Fully adhere insulation board in hot asphalt to appropriate substrate. Minimum 100 Square Feet.SPEC: 07 22 16.22SF12,000$0.00
A0143Furnish and install 1-1/2-inch to 3-1/2-inch polyisocyanurate insulation board. Secure insulation to deck/substrate with non-flammable adhesives for application of insulation or underlayment as per manufacturer’s requirements. Minimum 100 Square Feet.SPEC: 07 22 16.22SF2,000$0.00
A0144Furnish and install gypsum core glass mat asphaltic cover board (minimum 1/4 inch thick, 4 by 8 feet board size). Minimum 100 Square Feet.SPEC: 07 22 16.22SF6,000$0.00
A0145Furnish and install gypsum core glass mat thermal protection board (minimum 5/8 inch thick, 4 by 8 feet board size). Minimum 100 Square Feet.SPEC: 07 22 16.22SF6,000$0.00
A0146Furnish and install tapered polyisocyanurate insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/8-inch per foot minimum slope. Secure total thickness of insulation with penetrating type fasteners and preformed disks into the deck/substrate as per manufacturer’s requirements. Average tapered insulation system thickness 4 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF200$0.00
A0147Furnish and install tapered polyisocyanurate insulation board as per manufacturer’s requirements. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/8-inch per foot minimum slope. Fully adhere insulation in hot asphalt to appropriate substrate. Average tapered insulation system thickness 4 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF2,000$0.00
A0148Furnish and install tapered polyisocyanurate insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/8-inch per foot minimum slope. Secure insulation to deck/substrate with nonflammable adhesives for application of insulation or underlayment as per manufacturer’s requirements. Average tapered insulation system thickness 4 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF2,000$0.00
A0149Furnish and install tapered polyisocyanurate insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/8-inch per foot minimum slope. Mechanically fasten base layer to the substrate as per manufacturer’s requirements. Apply successive layers of insulation in hot asphalt. Average tapered insulation thickness 4 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF200$0.00
A0150Furnish and install tapered polyisocyanurate insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/8-inch per foot minimum slope. Mechanically fasten base layer of insulation board to the substrate as per manufacturer’s requirements. Apply successive layers insulation board with non-flammable adhesives for application of insulation. Average tapered insulation system thickness 4 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF200$0.00
A0151Furnish and install tapered polyisocyanurate insulation board as per manufacturer’s requirements. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Secure total thickness of insulation with penetrating type fasteners andpreformed disks. Average tapered insulation system thickness 5-1/2 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF200$0.00
A0152Furnish and install tapered polyisocyanurate insulation board as per manufacturer’s requirements. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Fully adhere insulation in hot asphalt. Average tapered insulation system thickness 5-1/2 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF6,000$0.00
A0153Furnish and install tapered polyisocyanurate insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Secure insulation to deck/substrate with nonflammable adhesives for application of insulation or underlayment as per manufacturer’s requirements. Average tapered insulation thickness 5-1/2 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF4,000$0.00
A0154Furnish and install tapered polyisocyanurate insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Mechanically fasten base layer to the substrate as per manufacturer’s requirements. Apply successive layers of insulation in hot asphalt. Average tapered insulation thickness 5-1/2 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF200$0.00
A0155Furnish and install tapered polyisocyanurate insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Mechanically fasten base layer of insulation board to the substrate as per manufacturer’s requirements. Apply successive layers insulation board with nonflammable adhesives for application of insulation. Apply successive layers of insulation in polyurethane foam adhesive. Average tapered insulation thickness 5-1/2 inches. Minimum 100 Square Feet.SPEC: 07 22 16.22SF200$0.00
A0156Furnish and install preformed crickets and tapered edge strips of polyisocyanurate insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Fully adhere insulation board to existing substrate. Average insulation thickness (3) inches. Minimum 50 Square Feet.SPEC: 07 22 16.22SF200$0.00
A0157Furnish and install preformed crickets and tapered edge strips of polyisocyanurate insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/2-inch per foot minimum slope. Fully adhere insulation board in hot asphalt to appropriate substrate. Average insulation thickness (6) inches. Minimum 50 Square Feet.SPEC: 07 22 16.22SF200$0.00
A0158Furnish and install preformed cant strips of polyisocyanurate insulation board. Incline face of cant strips to be 45 degrees with vertical height of (4) inch. Minimum 20 linear feet.SPEC: 07 22 16.22LF450$0.00
A0159Furnish and install supplemental fastening of insulation to prepared metal deck substrate with penetrating type fasteners and preformed disks into the deck/substrate as per manufacturer’s requirements for additional securement against increased wind uplift forces. 1 additional fastener per square foot. Minimum 1 square (SQ = 100 SF).SPEC: 07 22 16.22SQ300$0.00
A0160Furnish and install supplemental fastening of insulation to prepared gypsum, lightweight concrete, or Tectum deck substrate with penetrating type fasteners and preformed disks into the deck as per manufacturer’s requirements for additional securement against increased wind uplift forces. 1 additional fastener per square foot. Pre-drill holes in preparation to receive ‘auger’ type fasteners. Minimum 1 square (SQ = 100 SF).SPEC: 07 22 16.22SQ400$0.00
Section 07 22 16.23 - Roof Board Insulation (Expanded Polystyrene-EPS)
A0161Furnish and install vapor retarder to roof deck surface. Minimum 100 Square Feet.SPEC: 07 22 16.23 paragraph 2.4 and 2.7.1SF100$0.00
A0162Furnish and install 1-1/2-inch to 3-1/2-inch EPS insulation board. Mechanically fastened to the substrate as per manufacturer’s requirements. Minimum 100 Square Feet.SPEC: 07 22 16.23SF3,000$0.00
A0163Furnish and install 1-1/2-inch to 3-1/2-inch EPS insulation board. Fully adhere insulation board in hot asphalt to appropriate substrate. Minimum 100 Square Feet.SPEC: 07 22 16.23SF12,000$0.00
A0164Furnish and install 1-1/2-inch to 3-1/2-inch EPS insulation board. Secure insulation to deck/substrate with nonflammable adhesives for application of insulation or underlayment as per manufacturer’s requirements . Minimum 100 Square Feet.SPEC: 07 22 16.23SF2,000$0.00
A0165Furnish and install gypsum core glass mat cover board (minimum 5/8 inch thick, 4 by 8 feet board size). Minimum 100 Square Feet.SPEC: 07 22 16.23SF6,000$0.00
A0166Furnish and install gypsum core glass mat thermal protection board (minimum 5/8 inch thick, 4 by 8 feet board size). Minimum 100 Square Feet.SPEC: 07 22 16.23SF6,000$0.00
A0167Furnish and install tapered EPS insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/8-inch per foot minimum slope. Secure insulation to deck/substrate with non-flammable adhesives for application of insulation or underlayment as per manufacturer’s requirements. Average tapered insulation system thickness 4 inches. Minimum 100 Square Feet.SPEC: 07 22 16.23SF200$0.00
A0168Furnish and install tapered EPS insulation board system. Provide positive drainage with a top layer of cellar lightweight insulating concrete at 1/8-inch per foot minimum slope. Secure insulation to deck/substrate with cellar lightweight insulating concrete as per manufacturer’s requirements. Average tapered insulation system thickness 4 inches. Minimum 100 Square Feet.SPEC:03 52 00 and 07 22 16.23SF2,000$0.00
A0169Furnish and install tapered EPS insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/8-inch per foot minimum slope. Secure insulation to deck/substrate with non-flammable adhesives for application of insulation or underlayment as per manufacturer’s requirements. Average tapered insulation system thickness 5-1/2 inches. Minimum 100 Square Feet.SPEC: 07 22 16.23SF2,000$0.00
A0170Furnish and install tapered EPS insulation board system. Provide positive drainage with a top layer of cellar lightweight insulating concrete at 1/8-inch per foot minimum slope. Secure insulation to deck/substrate with cellar lightweight insulating concrete as per manufacturer’s requirements. Average tapered insulation system thickness 5-1/2 inches. Minimum 100 Square Feet.SPEC:03 52 00 and 07 22 16.23SF200$0.00
A0171Furnish and install tapered EPS insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Secure insulation to deck/substrate with non-flammable adhesives for application of insulation or underlayment as per manufacturer’s requirements. Average tapered insulation system thickness 4 inches. Minimum 100 Square Feet.SPEC: 07 22 16.23SF200$0.00
A0172Furnish and install tapered EPS insulation board system. Provide positive drainage with a top layer of cellar lightweight insulating concrete at 1/4-inch per foot minimum slope. Secure insulation to deck/substrate with cellar lightweight insulating concrete as per manufacturer’s requirements. Average tapered insulation system thickness 4 inches. Minimum 100 Square Feet.SPEC:03 52 00 and 07 22 16.23SF200$0.00
A0173Furnish and install tapered EPS insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Secure insulation to deck/substrate with non-flammable adhesives for application of insulation or underlayment as per manufacturer’s requirements. Average tapered insulation system thickness 5-1/2 inches. Minimum 100 Square Feet.SPEC: 07 22 16.23SF3,000$0.00
A0174Furnish and install tapered EPS insulation board system. Provide positive drainage with a top layer of cellar lightweight insulating concrete at 1/4-inch per foot minimum slope. Secure insulation to deck/substrate with cellar lightweight insulating concrete as per manufacturer’s requirements. Average tapered insulation system thickness 5-1/2 inches. Minimum 100 Square Feet.SPEC:03 52 00 and 07 22 16.23SF2,000$0.00
A0175Furnish and install preformed crickets and tapered edge strips of EPS insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Secure insulation to deck/substrate with non-flammable adhesives for application of insulation or underlayment as per manufacturer’s requirements. Average insulation thickness 3 inches. Minimum 50 Square Feet.SPEC: 07 22 16.23SF200$0.00
A0176Furnish and install preformed crickets and tapered edge strips of EPS insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/2-inch per foot minimum slope. Secure insulation to deck/substrate with non-flammable adhesives for application of insulation or underlayment as per manufacturer’s requirements. Average insulation thickness (6) inches. Minimum 50 Square Feet.SPEC: 07 22 16.23SF200$0.00
A0177Furnish and install preformed crickets and tapered edge strips of EPS insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/4-inch per foot minimum slope. Fully adhere insulation board in hot asphalt to appropriate substrate. Average insulation thickness (3) inches. Minimum 50 Square Feet.SPEC: 07 22 16.23SF200$0.00
A0178Furnish and install preformed crickets and tapered edge strips of EPS insulation board. Provide positive drainage with One (1) layer of factory tapered roof insulation at 1/2-inch per foot minimum slope. Fully adhere insulation board in hot asphalt to appropriate substrate. Average insulation thickness (6) inches. Minimum 50 Square Feet.SPEC: 07 22 16.23SF200$0.00
A0179Furnish and install preformed cant strips of EPS insulation board. Incline face of cant strips to be 45 degrees with vertical height of (4) inch. Minimum 20 Square Feet.SPEC: 07 22 16.23LF450$0.00
A0180Furnish and install supplemental fastening of insulation to prepared metal deck substrate with penetrating type fasteners and preformed disks into the deck/substrate as per manufacturer’s requirements for additional securement against increased wind uplift forces. 1 additional fastener per square foot. Minimum 1 square (SQ = 100 SF).SPEC: 07 22 16.23SQ10$0.00
A0181Furnish and install supplemental fastening of insulation to prepared gypsum, lightweight concrete, or Tectum deck substrate with penetrating type fasteners and preformed disks into the deck as per manufacturer’s requirements for additional securement against increased wind uplift forces. 1 additional fastener per square foot. Pre-drill holes in preparation to receive ‘auger’ type fasteners. Minimum 1 square (SQ = 100 SF).SPEC: 07 22 16.23SQ10$0.00
Section 07 31 13 - Asphalt Shingles
A0182Furnish and install single layer of felt underlayment on roof deck perpendicular to roof slope in parallel courses. Lap sides a minimum of (2) inches over underlying course. Lap ends a minimum of (4) inches. Stagger end laps between succeeding courses at least (72) inches. Fasten with felt underlayment roofing nails. Minimum 100 Square Feet.SPEC: 07 31 13 DWG. 4.01, 4.02 and 4.03SF2,000$0.00
A0183Furnish and install double layers of felt underlayment on roof deck perpendicular to roof slope in parallel courses. Install a (19) inch wide starter course at eaves and completely cover with full-width second course. Install succeeding courses lapping previous courses (19) inches in shingle fashion. Lap ends a minimum of (6) inches. Stagger end laps between succeeding courses at least (72) inches. Fasten with felt underlayment roofing nails. Minimum 100 Square Feet.SPEC: 07 31 13 DWG. 4.01, 4.02 and 4.03SF2,000$0.00
A0184Furnish and install self-adhering sheet underlayment; wrinkle free, on roof deck. Install in direction to shed water. Lap sides not less than 3-1/2 inches. Lap ends not less than (6) inches staggered (24) inches between courses. Roll laps with roller. Minimum 100 Square Feet.SPEC: 07 31 13 DWG. 4.01, 4.02 and 4.03SF1,000$0.00
A0185Furnish and install Fiberglass Reinforced Asphalt Shingles, Mineral granule-surfaced asphalt shingles, self-sealing, square tab, strip, fungus-resistant architectural shingles weighing not less than 290 pounds per 100 square feet as per manufacturer’s requirements. Include the installation of associated items, including hip and ridge shingles and miscellaneous perimeter and trim flashings. Minimum 100 Square Feet.SPEC: 07 31 13 DWG. 4.01, 4.02 and 4.03SF2,000$0.00
A0186Furnish and install standard high-density polypropylene or other UV-stabilized plastic ridge vent with non-woven geo-textile filter strips and external deflector baffles; for use under ridge shingles as per manufacturer’s requirements. Minimum 100 Linear Feet.SPEC: 07 31 13LF100$0.00
Section 07 32 00 - Concrete and Clay Tile Roofing
A0187Furnish and install single layer of felt underlayment on roof deck perpendicular to roof slope in parallel courses. Lap sides a minimum of (2) inches over underlying course. Lap ends a minimum of (4) inches. Stagger end laps between succeeding courses at least (72) inches. Fasten with felt underlayment roofing nails.SPEC: 07 32 00SF2,000$0.00
A0188Furnish and install self-adhering sheet underlayment, granular surfaced; wrinkle free, on roof deck. Install at locations indicated on construction documents, lapped in direction to shed water. Lap sides not less than 3-1/2 inches. Lap ends not less than (6) inches staggered (24) inches between courses. Roll laps with roller.SPEC: 07 32 00SF2,000$0.00