SOW_BLDG_1470_(26_May_2015).docx
DOCX document 30 KB Posted
- Attached to
- Amendment 1
- Solicitation number
- FA2517-15-T-6006
About this file
Revised SOW after site visit
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attch_3_-_Lodging_PWS.docx | DOCX document | |
| Attch_1_-_BPA_Terms_and_Conditions.docx | DOCX document | |
| Attch_2_-_252.209-7999_Fill_In.docx | DOCX document | |
| Attch_4_-_Questions_and_Answers.docx | DOCX document | |
| RFQ_-_Lodging_BPA _Amendment_1.docx | DOCX document | |
| Site_visit_Q A.docx | DOCX document | |
| Attachment_3_SOW.docx | DOCX document | |
| FA2517-15-T-6006_-_SCIF_Security.docx | DOCX document | |
| Attachment_1_-_Contractor_Submittal_Form.docx | DOCX document | |
| Attachment_4_-_Site_Visit.docx | DOCX document | |
| Attachment_5_-_Additional_Terms_ _Conditions.docx | DOCX document | |
| Attachment_2_Material_ _Equipment.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK (SOW)
SCIF Security System Upgrade 26 May 2015
1. Description of Service: Security system upgrades are required in order to continue certification of room 126 located in building 1470 on Peterson AFB. All equipment installed in support of this requirement shall be compatible with the current security system. The current security system is the General Electric (GE) Diamond II.
2. Requirements: An upgrade of the security system for room 126 is required to add two (2) positive means of access control to ensure the facility is in accordance with DoDM 5105.21. The requirement includes the installation and programming of access control equipment, including but not limited to, proximity card reader/keypad, Arm/Disarm keypad, emergency release button, electric door strike, 360 degree motion detectors, GE Intelligent Controller, Balanced Magnetic Switch (BMS), and other associated equipment/conduit required to meet the requirements of DoDM 5105.21.
2.1 Entry Door Upgrade: This will require the addition of one (1) proximity card reader/keypad, one (1) arm/disarm keypad, one (1) electric door strike to control access to the entry door of the facility along with the installation of one (1) emergency release button. In addition, the vendor shall remove the existing door latch and the X09 lock from the entry door. Install a metal plate to cover all holes and reinstalled the X09 lock.
2.2 Motion Detector Upgrade: Add one (1) 360 degree motion sensor at the rear emergency exit doors and add one (1) 360 degree motion sensor close to the main entry door to ensure coverage of the doors. Replace the existing 360 motion detector located next to the equipment double doors with the 360 motion detector in the center of the room. Ensure all entry/exit doors to the room 126 are also equipped with one (1) Balanced Magnetic Switch (BMS) sensors and are operational.
2.3 Hardware Interface: Install (1) GE Intelligent Controller, as well as any associated conduit/cabling as necessary to interface the security equipment to the existing Intrusion Detection monitoring system.
2.4 Software Interface: Peterson AFB has an existing Protection Level (PL) 4 Intrusion Detection System (IDS), for access control and intrusion detection monitoring. Perform any necessary actions required to incorporate/configure all ESS equipment into the existing Air Force (AF) certified monitoring Diamond/WinX system. These actions shall only be performed by personnel that are currently certified by GE for the GE Diamond system.
3.0 Work Hours: All work shall be completed Monday thru Friday between the hours of 0730 and 1630 excluding Federal Holidays.
4.0 System Activation: The existing security system in room 126 shall remain operational during the security system upgrade. Activation of new equipment will take place during the work hours specified in paragraph 4 above with the system being 100% operation at the end of each work day.
5.0 Materials/Warranty: All materials provided by the vendor in the performance of this contract cannot be used, or refurbished; all materials, equipment and parts provided by the vendor must be new. Equipment items will be provided with a minimum manufacturer warranty of 1 year. In addition, the installation shall be warranted for workmanship for a period of 1 year.
File details come from the government source that posted it. Updated .