Attachment 4 - Questions Answers.pdf

PDF 832 KB Posted

Attached to
99 ABW Command Post Regional Console
Solicitation number
F3G3EA5195A002
Issued by

About this file

This document is a Questions and Answers attachment for a CP Regional Console procurement (Solicitation Number F3G3EA5195A002). The Q&A addresses several technical specifications, including:

Monitor and Equipment Spacing: The PCs and ports are 58" apart, 49" monitors are 15" apart, and 20" UNIFY phone/radio system screens are 4-6 inches from the main monitors. The console requires minimal cable and monitor separation. Power cables are needed only for raising and lowering console positions. The existing console is a single hard surface with side-opening doors for cable and UPS system routing. The images show the current workstation setup with multiple monitors, including large curved screens, smaller operational screens, keyboards, and various work materials.

View the file

Other files

File Type Posted
Attachment 4 - Questions Answers.pdf PDF
Attachment 1 - SOW.pdf PDF
Attachment 3 - Renderings.pdf PDF
Attachment 2 - Command Post Floor Plan.pdf PDF
Attachment 1 - SOW.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F3G3EA5195A002 - CP Regional Console

Attachment 4 – Questions and Answers

Q: Attachment 1 – SOW Section b.i.1. notes separation between computers. Can you confirm the distance as it is not noted?

A: The distance between the PCs and ports they plug into is 58” apart. If you are referring to the distance between the 49” monitors it is 15” apart.

Q: Does there need to be separation spacing between cables and monitors in addition to the computer spacing?

A: Yes, some separation would be required not much.

Q: Can you provide the size of the smaller third monitor at each position?

A: The UNIFY phone/radio system 20” inch screens are the smaller monitors you see displayed in attachment 3 , these are essential and used for daily operations. The screens were measured to be between

4-6 inches apart from 49” monitors.

Q: Attachment 3 - Rendering document shows phone shelves, but Attachment 1 – SOW does not indicate they are required. Can you confirm they are not required?

A: They should not be required the actual phone system should be mounted just like the 49” monitors.

Q: Attachment 1 – SOW Section c.v.iii. indicates the console vendor is to provide power cables. Can you confirm that this is a monitor power cable and provide the type of power cable required?

A: The only power cables needed should be for the console itself to raise and lower each specific position.

Q: Attachment 1 – SOW Section 1.1.1 - are there photos or any sort of description of the existing furniture that needs to be removed and disposed of?

A: Please see the pictures attached. The current console is one entire hard surface. Under the counter top is a set of doors that open on both sides for cabling and UPS systems to be run through.

File details come from the government source that posted it. Updated .