Attachment 5 - Engineered Drawing Example.pdf
PDF 1 MB Posted
- Attached to
- 31 CTS JITTC-N Trailer Furniture
- Solicitation number
- F3G0CB5126AW01-2
About this file
This file is an engineered drawing for a modular office building designed by Phoenix Modular for Pacific Mobile Structures. The 4,320 square foot, six-module building is configured for office use, with specifications including a 72'x60' footprint, Type VB construction, and Occupancy Group B classification. The structure features 2x6 exterior wall framing, R-21 insulation, 2x10 rafters, R-38C roof insulation, white EPDM roofing, and vinyl-covered gypsum wall coverings in colors like Adobe Incan Frost and Pacific Mobile Grey.
The building includes six individual office spaces, two restrooms, and various electrical and HVAC components. Electrical features include 120/240V panels, LED lighting, occupancy sensors, and GFCI receptacles. HVAC consists of 3-ton AC units with heat strips, 24"x24" diffusers, and return air grilles. Plumbing includes water closets, lavatories, and a mop sink. The modular design allows for potential site-specific customization, with a 7'-10" ceiling height and specifications compliant with 2018 International Building Code standards. The drawing provides comprehensive architectural, structural, electrical, HVAC, and plumbing details for precise manufacturing and on-site installation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FINISHES:
FLOOR COVERING:
Type 1: 0.080 Sheet vinyl (Flat) Location: (Restrooms and Janitor's Closet) Color to be: (Uncommon Gray)
Type 2: Carpet ready (Flooring supplied & installed at site by others) Location: (Remainder)
BASE:
Cove Base 1 : 4" Rubber cove.
Location: (Restrooms and Janitor's Closet) Color to be: (Gray Mist)
Cove Base 2: Provided & Installed on site by others.
Location: (Remainder)
WALLS:
Covering 1: 1/2" vinyl covered gypsum (7/16" OSB above Ceiling to Bottom of Rafters)
Location: (Sidewalls) Covering height: 8' (VCG) Remainder (OSB)
Color to be: (Adobe Incan Frost)
Covering 2: 1/2" vinyl covered gypsum Location: (Remainder) Covering height: 8'
Color to be: (Adobe Incan Frost)
Covering 3: Standard FRP panels (All Walls) Location: (Restrooms & Janitor's Closet) Covering height: 4' Color: (White)
TRIM:
Wall Trim 1: Vinyl Covered trim
Color to be: (To match VCG) (Bottom 18 in. held loose)
Wall Trim 2: Vinyl Covered Battens Location: Doors & Windows (Cut seams over and under doors/windows) Color to be: (To match VCG)
Wall Trim 3: Vinyl Covered Battens Location: Office walls @ cielings Color to be: (To match VCG)
CEILING:
Type 1: 2'x4' HEAVY DUTY T-Grid w/ Struts & wires
(Armstrong Tile #1729A or Equal) Height: 7'-10"
Installed at factory, held back at module lines.
Completion of ceiling installation on-site by others; not in PMI's scope.
EXTERIOR
Siding body: Color: (Pacific Mobile Grey) 8' sheets Hood: Color: (Pacific Mobile Grey) Corner trim: Color: (Pacific Mobile Blue) Door trim: Color: (Pacific Mobile Grey) Window trim: Color: (Pacific Mobile Blue) Bottom horizontal trim: Color: (Pacific Mobile Blue) Intermediate horizontal trim: No trim provided. Z-bar only. Color: (Pacific Mobile Grey) separates hood & body Top horizontal trim: Color: (Pacific Mobile Blue) Module line trim: Color: (Match hood above intermediate horizontal trim & match body below) All paint to be: Satin Finish (Sherwin Williams) All caulk to be: Vulkem 116
INTERIOR WALL CONSTRUCTION:
Framing: Stud: 2X4 #2 HF equal or better @ 16" O.C.
Top plate: Single 2X4 #2 HF equal or better (Double as needed) Bottom plate: Single 2X4 #2 HF or better bottom plate w/ single top plate Stud length: 92-5/8" (Ceiling Ht.) (See hatching on floor plan) Stud length: 90-3/4" Remainder
Insulation: None Additional Interior Wall Items Included in Quoted Price:
Item 1: 5/8" Raw gypsum (ONE Side) Location: (Inside of 2x4 Stud @ Plenum) Covering height: 8 ft.
(See hatching for location)
Item 2: 2x6 PLUMBING WALL. SEE SHEET WS FOR LOCATION
FRAME / CHASSIS:
Frame Type: Basement Quantity: (6) EA Size: Modules 1 & 6: 11'-7 1/4" X 59'-10 1/2"
Modules 2 & 5: 11'-8" X 59' 10 1/2" Type: Outrigger @ 48" O.C.
Crossmember @ 96" O.C.
Module line Clips @ 96" O.C.
Main Rails @ 99 1/2" O.C.
Beam Size: 12" Jr. I-beam Axles:
Modules #: Qty: Quad 6000# rated with (All) brake Offset: None
Hitch: Detachable with Standard Hitch Tires: 8x14.5 14 ply rated
Additional Frame / Chassis Items Included in Quoted Price:
Item 1: Outriggers without marriage clips (sidewall) to be 3/4 in. shorter modules.
Item 2: Outriggers with marriage clips (modline side) to be factory standard size Item 3: Add crossmember at front and back of axles
FLOOR CONSTRUCTION:
Floor Joist: 2X8 #2 HF equal or better Joist Length: 133-7/8" Joist Spacing: 16" O.C.
Floor: Single layer 3/4" T&G Plywood.
Insulation: R-30 unfaced fiberglass batt (2-layer of R-15) Bottom: Reinforced Plastic
Additional Floor Items Included in Quoted Price:
Item 1: See detail B/6 for bottom belly.
EXTERIOR WALL CONSTRUCTION:
Framing: Stud: 2X6 #2 HF equal or better @ 16" O.C.
Top Plate: Double 2X6 #2 HF equal or better Bottom Plate: Single 2X6 #2 HF or better Header: (3) 2x4 header with (2) 1/2" shim at all exterior openings (UNO)
Insulation: R-21 Kraft back fiberglass batt Siding Type: 7/16" LP Smart-panel vertical siding (8" grooves) with barricade wrap underlayment over bottom belly. (See Detail B/6) Sidewall Height: See cross section for heights
Additional Exterior Wall Items Included in Quoted Price:
Item 1: Start siding install from rear of building (opposite hitch) (Sidewall only) Item 2: 2x2 Galvanized flashing under corner trim (See detail A/6) Z-bar at floor (See detail B/6) Item 3: See detail C/6 for window flashing, detail 4/6 for window and door framing, and detail B/6 for floor bottom.
ROOF CONSTRUCTION:
Roof Type: Complex Roof Slope: 1/4 in 12 Rafter size: 2X10 #2 HF equal or better
(Roof diaphragm chord strap 'ST2215' at rafters installed on-site, see 2/6) Rafter Length: Modules 1 & 6= 133 1/8"
Modules 2 - 5= 129 1/4" Spacing: 24". O.C. (Sheathing clips required) Mate Beam: Steel clearspan web truss with (wood) columns at each end
Height: 22 1/2" to 30" to 22 1/2" Length: 60' No. of Beams: 10
Insulation: R-38C unfaced fiberglass batt (Shepweave II) Sheathing: 1/2" 24/0 Sheathing Roofing: 45 mil single ply EPDM over 1/4" Densdeck
Color: White
Additional Roof Items Included in Quoted Price:
Item 1: J-Rail to be installed with grommets and screws (See Detail D/6).
Item 2: See detail E/6 for trim installation.
Item 1: Add 2x4 runner centerline on underside of rafters, 8' from each end, fastened with (2) 10d nails each rafter. (See detail 5/6)
EXTERIOR/INTERIOR DOORS: (SEE DOOR SCHEDULE)
WINDOWS: (SEE WINDOW SCHEDULE)
CLOSEUP:
Type: Medium (Plastic Provided by PMS) Notes: Module WILL NOT exceed 12'-0" (Except door hardware)
ACCESSORIES:
Dealer Signs: Provided by Dealer and installed at factory (See Elevations for locations) Base Cabinets: 8 L.F.
Color: Pre-Finish (Maple Rye) Counters: 8 LF of 25-1/2" wide Laminate Countertop
Backsplash: 4" Edge Type: Rolled Color: (TBD)
"PLEASE REVIEW DRAWINGS AND SPECIFICATIONS
CAREFULLY. WHILE EVERY EFFORT IS MADE TO
ASSURE THE DRAWINGS REFLECT THE
EXPECTATIONS AND QUOTATION, THE FINAL
CONSTRUCTION WILL BE BASED SOLELY ON THE
SPECIFICATIONS AND DRAWINGS APPROVED."
APPROVED
APPROVED EXCEPT AS NOTED
REVISE AND RESUBMIT
BY: DATE:
DEALER:Phoenix Modular
PROJECT:TBD
OFFICE (WET)
72'X60' - 2024
PMI-TBD
OF
W . M
A D
IS
O
N S
T.
PH
O
EN
IX
, A Z
PH
-4
-6
F A
X
-4
-6
SU
N
B
EL
T M
O D
U
LA
R
IN
C
SHEET:
THESE DRAWINGS
REMAIN THE PROPERTY
OF PHOENIX MODULAR
AND ARE NOT TO BE
USED IN ANYWAY
WITHOUT WRITTEN
PERMISSION.
DEALER:
PACIFIC MOBILE
STRUCTURES
PROJECT:
OFFICE (WET)
STATES:
NV
SERIAL NUMBERS:
PMI-TBD
DRAWN BY:
TBD
PLOT DATE:
TBD
REV # / DATE:
MODEL NUMBER:
PH
O
EN
IX M
OD
UL
AR
PMI-TBD
© 2024
SHAYLON VAUGHN, P.E.
CORPORATE ENGINEER
5301 W. MADISON ST.
PHOENIX, AZ 85043
(602) 447-6460
DATA PLATE AND STATE DECAL TO BE LOCATED ON
LOWER RIGHT HAND CORNER OF THE ENDWALL
OPPOSITE THE HITCH END OF THE MODULE.
SPRINKLERS REQUIRED: NO
FIRE ALARM REQUIRED: NO
SPECIAL CONDITIONS AND / OR
LIMITATIONS:
IDENTIFICATION:
NOTES:
1. SITE PLAN NOT AVAILABLE AT THIS TIME. BUILDING
DESIGNED TO HAVE FIRE SEPARATION DISTANCE
GREATER THAN 10 FT. TO PROPERTY LINES AS PER
LOCAL BUILDING DEPARTMENT REQUIREMENTS.
2. THIS PLAN MAY BE REVERSED AND/OR MIRRORED.
3. SEE STRUCTURAL PACKAGE FOR ALL STRUCTURAL
STANDARDS AND DETAILS.
4. BUILDING WILL NOT BE LOCATED IN A FLOOD HAZARD
AREA.
5. BUILDING SHALL NOT BE SITED WHERE LOCAL
CONDITIONS EXCEED THE DESIGN PARAMETERS.
6. STRUCTURAL SKIRTING / FRAMING, BY OTHERS, IS
REQUIRED FOR SNOW LOADS EXCEEDING 20 psf.
APPROVAL # F8073-2
MANUFACTURER:
DESIGN CRITERIA / LOADS:
NOT INCLUDED IN SCOPE OF WORK:
1. PORCHES, STEPS, AND RAMPS TO BE SUPPLIED AND
INSTALLED BY OTHERS IN ACCORDANCE WITH THE
LOCAL BUILDING DEPARTMENT
2. PORTABLE FIRE EXTINGUISHERS TO BE SUPPLIED AND
INSTALLED ON SITE BY OWNER IN ACCORDANCE WITH
LOCAL BUILDING DEPARTMENT
3. ACCESSIBLE DRINKING FOUNTAIN TO BE PROVIDED
ON SITE BY OWNER (AS APPLICABLE)
4. ANY REQUIRED SPRINKLER / FIRE ALARM /
FIRE/SMOKE DETECTION AND/OR SUPPRESSION AS
REQUIRED BY THE IBC/IFC AND/OR LOCAL FIRE
AUTHORITY TO BE INSTALLED BY OTHERS ON SITE IN
ACCORDANCE WITH THE LOCAL BUILDING
DEPARTMENT.
5. THE BUILDING OWNER IS RESPONSIBLE FOR THE
DEVELOPMENT & DESIGN OF ALL SITE REQUIRED
ACCESSIBILITY ELEMENTS. THESE ELEMENTS ARE
NOT INCLUDED IN THE SCOPE OF THIS DESIGN.
SUBMITTALS ARE REQUIRED BY OWNER THROUGH
THEIR DESIGN PROFESSIONAL.
AZ: 2018 IBC, 2018 IPC, 2018 IMC, 2017 NEC, 2018 IECC,
2018 IFC, AND ICC A117.1-2009
MANUFACTURER & ADDRESS PHOENIX MODULAR
5301 W. MADISON ST.
(SEE WEBSITE FOR PHOENIX, AZ. 85043
WARRANTY INFORMATION) PHOENIXMODULAR.COM
Ss=0.97, S1=0.33 Site Class 'D' Design Category 'D'
NO OF MODULES. 6
BUILDING SQ.FT. 4320
TYPE OF CONSTRUCTION. VB
OCCUPANCY USE GROUP. B
OCCUPANCY LOAD. 45
FLOOR LIVE LOAD. 50 psf. (2000 lb concentrated)
(100 psf. @ conference room) 80 psf. @ Open Office 101
ROOF LIVE LOAD. 20 psf.
ROOF DEAD LOAD. 12 psf.
ROOF SNOW LOAD. 30 psf.
WIND LOAD.
OCCUPANCY/RISK CATG. II
SEISMIC
PERMISSIBLE GAS TYPE. N/A
CLIMATE ZONE. 2b, 3b, 4b
NAME AND DATE OF CODES;
STATE REQUIRED INFORMATION ON USE AND
LOCATION OF FACTORY-BUILT BUILDING
1. PROPOSED ADDRESS
2. EXPLANATION OF
AND/OR LOCATION OF UNIT.
BUILDING USE.
3. SET TYPE
ASSUMED F.F. TO BE 36" A.F.G.
Office
Stock Stock
PAD/PIER ABOVE GRADE
RED TAG:
2018 IBC - 115 MPH, EXP. C
RED TAG NOT REQUIRED
Vasd - 89 MPH, EXP. C
V - 115 MPH, EXP. C
DRAWING INDEX
SHEET 1: SPECIFICATIONS AND CONDITIONS
SHEET 2: FLOOR PLAN, PLUMBING LEGEND, STRUCTURAL
LEGEND, WINDOW AND DOOR SCHDULE, AND
PLUMBING SCHEMATICS
SHEET 3: ELECTRICAL PLAN, ELECTRICAL LEGEND,
ELECTRICAL CALCS AND ELECTRICAL NOTES
SHEET 4: REFLECTED CEILING PLAN
SHEET 5: HVAC PLAN, HVAC SCHEDULE
SHEET 6: BUILDING CROSS-SECTION & DETAILS
SHEET 7: ELEVATIONS
MODULE ( )1
1 1
'-6
11'-2"11'-3 1/2"11'-3 1/2"11'-3 1/2"
'-6
'-6
'-6
6' -6
7'-3"
6' -6
HC
7'-3"
HC
'-4
'-4
'-4
'-4
'-4
'-4
DUAL
128 SF
OFFICE
BARE FLOOR
130 SF
OFFICE
BARE FLOOR
130 SF
OFFICE
BARE FLOOR
130 SF
OFFICE
BARE FLOOR
47 SF
RR
VINYL
IM
A
A
02 02 02 02
HVAC HVAC HVAC HVAC HVAC HVAC
PANEL A 111111111111 PANEL B PANEL C PANEL D PANEL E PANEL F
MODULE ( )2 MODULE ( )3 MODULE ( )4 MODULE ( )5 MODULE ( )6
A
A1 1 A1 1 A1 1 A1 1 A1 1 A1 1
A
A
61'-4 1/2"
69'-0"
5' -6
'-7
'-9
'-5
'-5
'-9
'-0
3'-11" 11'-8" 3'-8" 11'-8" 3'-8" 11'-8" 3'-8" 11'-8" 3'-8" 11'-8" 3'-8" 11'-8"
5' -6
'-5
/8
'-0
70'-0"
A
A
" M
IN
1 1 1 1
1 1 1 1 1
47 SF
RR
VINYL
'-5
'-9
PLUMBING:
Symbol Type Qty Note Description
H C
IM
DUAL
W H
Water Closet
Grab Bars
Paper Holder
Lavatory
Sink
Sink
Mirror
Drinking Fountain
Valves
Water Heater
Water Heater
In-line Strainer Supply
DWV
System
R.R. Sign
R.R. Sign
Low Flow (Thermostatic Mixing Valves)
Chronomite:
S70LLMB240V or equal
6 gallon w/ seismic straps
1"
Copper Inlet
Door Mtd
Wall Mtd
Floor mtd. ADA elongated tank type with shut off valve / flush handle to be on open side of r.r., and open front seat (Factory standard) Set(s) with (1) each 42", 36" horizontal, and 18" vertical Single roll wall mount toilet paper holder mtd.
ADA height (Factory standard)
19" X 17" White vitreous wall hung with ADA handles and shut off valves. (Factory standard)
25" X 22" Stainless steel single bowl sink with single faucet, ADA handle, and shut off valves (Factory standard) 24x24 Floor mounted mop sink with wall mounted faucet (Factory standard) 24"x36" w/ clips mtd. 38" to bottom edge (Factory standard) Wall hung split-level handicap refrigerated with cane apron (30" to lower spout) (Factory standard) Valve box for ice maker mtd. 12" a.f.f. (Factory standard) (Ice maker by others)
Insta-Hot Chronomite S-70 (Electric - 240V)
120v Electric with relief valve, water tight drain pan (3/4" drain), and pipe insulated first 8' (non-simulataneous operation) (Factory standard)
Strainer at supply entrance
Type M copper or Pex
ABS Schedule 40 (Manifold is by others)
Unisex ADA restroom sign mtd. 59" a.f.f. to center Unisex ADA restroom sign w/ braille mtd. 59" a.f.f. to center
DOORS:
Qty NO. Type Jamb Wall Thickness Glazing Size Rough Opening U-Factor Color Closer Deadbolt Hardware Fire Rating Keying Notes
STEEL, INSULATED 18 GA.
PREFINISHED WOOD
SOLID CORE
PREFINISHED WOOD
SOLID CORE
KD 16 GA.
PACIFIC
MOBILE GRAY
TIMELY METAL
FRAME
BROWNTONE
TIMELY METAL
FRAME
BROWNTONE
6 3/8"
4 1/2"
4 1/2"
NONE
NONE
NONE
3/0X6/8
3/0X6/8
3/0X6/8
38" x 81"
37 1/2" x 80 3/4"
37 1/2" x 80 3/4"
0.31
N/A
N/A
PACIFIC MOBILE GRAY
(SAME BOTH SIDES)
LEGACY OAK
LEGACY OAK
HYDRAULIC (TELL
12916, TAP & DRILL)
(NO THROGUH
BOLTS)
NONE
NONE
SINGLE CYLINDER (DB2051)
NONE
NONE
PASSAGE LEVER, GRADE
2 (TELL LC2675CTL) NO
THRU BOLTS
PASSAGE LEVER, TELL
GRADE 2 (LC2676 CTL)
REMOVE THRU BOLTS
PRIVACY LEVER, TELL
GRADE 2 (LC2676 CTL)
REMOVE THRU BOLTS
NONE
NONE
NONE
ALIKE
N/A
N/A
DRIP CAP, (3) S.S. B.B. NRP HINGES,
WEATHERSTRIPPING, THRESHOLD, &
DOOR SWEEP, INCLUDE SIGN (THIS DOOR
TO REMAIN UNLOCKED WHEN BUILDING IS
OCCUPIED MOUNTED ABOVE EXTERIOR
DOOR) MASTER KEY CORE STAMP
HINGES & WALL MOUNT STOPS
HINGES & WALL MOUNT STOPS
WINDOWS:
Qty NO. Type Glazing Size Rough Opening U-Factor SHGC Mini-Blind Notes
13 A
WHITE VINYL
HORIZONTAL
SLIDER
CLEAR, DUAL
GLAZED, LOW-E 4/0X3/0 48" x 36" 0.31 0.23 HORIZONTAL ALUMINUM.
COLOR: (WHITE) HEADER AT 81" AFF
WALL HATCHING LEGEND:
2x4 CEILING HT. WALL WITH 5/8" RAW GYPSUM
ON PLENUM SIDE OF WALL SEE WALL FINISH
SCHEDULE FOR WALL COVERING.
2x4 CEILING HEIGHT WALL
SEE WALL FINISH SCHEDULE FOR WALL
COVERING.
STRUCTURAL LEGEND
Symbol Description Qty
**ALL INTERIOR DIMENSIONS ARE FROM FINISH TO FINISH
& ALL EXTRIOR DIMENSIONS ARE FROM STUD TO STUD**
X
X
SHEARWALL TAG
(SEE STRUCTURAL PACKAGE FOR
DESCRIPTION, SEE SHEET 24)
HOLD DOWN TAG
(SEE STRUCTURAL PACKAGE FOR
DESCRIPTION, SEE SHEET 24)
DIAPHRAGM CHORD TIE SIMPSON 'ST2215'
(SEE DETAIL 2/6)
(1) 3.5"x5.25" LVL 2.0 E GRADE ON EACH
SIDE OF MOD-LINE (TYP. #3 HOLDOWN
STRAP @ BOTTOM & BOLTED @ TOP)
TYP @ 4
LOCATIONS
TYP @ 61
LOCATIONS
TYP @ 10
LOCATIONS
TYP @ 10
LOCATIONS
WASTE & VENT LEGEND
DESCRIPTIONSYM
WASTE DRAIN (FACTORY INSTALLED)
WASTE DRAIN (SUPPLIED & INSTALLED BY OTHERS)
WASTE VENT (FACTORY INSTALLED)
NOTE:
1. ALL PIPE TO BE ABS SCHEDULE 40 & WILL SLOPE 1/4
PER FOOT.
2. PLUMBING MANIFOLD TO BE SUPPLIED & INSTALLED
AT SITE BY OTHERS.
3. ALL PLUMBING VENTS ARE INSTALLED 6" ABOVE
ROOF. IF VENT IS REQUIRED TO BE TALLER BY
LOCAL AHJ, THEN EXTENSION SHALL BE SUPPLIED
AND INSTALLED AT SITE BY OTHERS.
COLD & HOT SCHEMATIC
1. MAX PRESSURE RANGE @ CONNECTION:
2. MAX DEVELOPED LENGTH:
NOTE:
A. PEX HOT / COLD WATER SUPPLY MAY BE INSTALLED
ABOVE CEILING.
30-39 (IPC)
100'
DESCRIPTIONSYM
COLD WATER LINE
HOT WATER LINE
V.T.R 3"
LTTY
<<<3" TO MAIN
DBL
WYE
3"
W.C.
W.C.
3"
LTTY
LTTY
SAN-T
2" 2"
LAV.
LTTY
SAN-T
2" 2"
LAV.
LTTY
SAN-T
2" 2"
M.SINK
LTTY
C.O.
C.O.
3"
3"
2"
2"
2"
2"
SAN-T
2"
SINK
M
IN
" A
BO
VE
R
IM
O F
SI
N
K
1/ 2"
D.F.
1/ 2"
W.C.
1/ 2"
W.C.
1/ 2" 1/
2"
LAV.
LAV.
M.SINK
1/ 2"
1/ 2"
SINK
1/ 2"
1/ 2"
1" INLET
G.V.
INLINE
STRAINER
W.H.
1"
1"
3/4"
3/4" 3/4"
3/4"
3/4"
1/ 2"
I.M.1/ 2"
I.M.
3/4"
3/4"
DESCRIPTION QTY FIXTURE
UNITS
Breakroom 1 10
LAVATORY 2 8
SINK 2 3
DRINKING FOUNTAIN 1 0.25
TOTAL FIXTURE UNITS: 20 = 1" INLET
HANDICAPPED WATER
CLOSET SIDE VIEW
(ADULT HT.)
HANDICAPPED WATER
CLOSET FRONT VIEW
(ADULT HT.)
1'-0" MIN
36" MIN.
18"
1'-0"
MAX18
" M
IN
" T O
1"
39" TO 41"
" M
IN
" T
O
1"
" M
IN
T
O T
O P
TO
6" M
AX
TO
T
O P
" M
IN
T
O T
O P
TO
6" M
AX
TO
T
O P
42" MIN.
54" MIN.
2'-0" MIN
37"
1- 1/
2" M
IN
9" MAX
17" MIN
FIXTURE
DEPTH
6" MAX
TOE CLEARANCE
9" M
IN
" M
IN
" M
AX
" M
IN
8"
KNEE CLEARANCE
" M
IN
17" MIN.
19"
MAX.48" MAX.
5"
CLEAR FLOOR SPACE
AT LAVATORIESLAV CLEARANCES
WRAP ALL
EXPOSED
PIPES
MIRROR
CLEAR
FLOOR
SPACE
FLOOR HATCHING LEGEND:
(100 PFS. FLOOR LOAD)
9" M
IN
6" MAX
TOE CLEARANCE
CLEAR FLOOR SPACE
AT DRINKING FOUNTAIN
15"
MIN.
5"
MAX.
17" MIN.
-25" MAX.
" M
AX
W H
EE
LC
H
AI
R
AC
C
ES
SI
BL
E
ST
AN
D
IN
G
PE
R
SO
N S
" M
IN
1 FLOOR PLAN
1/4"=1'-0" SQUARE FOOTAGE - 4320 S.F.
OCCUPANCY LOAD = 45
OF
W . M
A D
IS
O
N S
T.
PH
O
EN
IX
, A Z
PH
-4
-6
X
-4
-6
SU
N
B
EL
T M
O D
U
LA
R
IN
C
SHEET:
THESE DRAWINGS
REMAIN THE PROPERTY
OF PHOENIX MODULAR
AND ARE NOT TO BE
USED IN ANYWAY
WITHOUT WRITTEN
PERMISSION.
DEALER:
PACIFIC MOBILE
STRUCTURES
PROJECT:
OFFICE (WET)
STATES:
AZ
SERIAL NUMBERS:
PMI-6333-7260
DRAWN BY:
RQ/CK
PLOT DATE:
6/10/2024
REV # / DATE:
MODEL NUMBER:
PH
O
EN
IX M
OD
UL
AR
PMI-PMS-7260 AZ
© 2024
SHAYLON VAUGHN, P.E.
CORPORATE ENGINEER
5301 W. MADISON ST.
PHOENIX, AZ 85043
(602) 447-6460
3 HOT / COLD SUPPLY
N.T.S.
4 D.W.V.
N.T.S.
ELECTRICAL:
Symbol Type Qty Note Description
PC
O
H
HT
OCC
GFCI
GFCI
WR
DED
DED
GFCI
E
T
Elec Service Elec
Raceway
Elec Panel
Elec Panel
Lights
Lights
Lights
Lights
Switch
Switch
Switch
Switch / Recep
Occupancy Sensor
Receptacle
Receptacle
Receptacle
Receptacle
Receptacle
Receptacle
Floor Box
J-Box
J-Box
Water Heater J-Box
J-Box
J-Box
Exhaust Fan
T-Stat
Device Color
Min. 12 Space
Min. 20 Space
(PANEL F)
50W
30W
HARRIS 300
(300-LED-1K-CP
-HK-PC-120)
Wattstopper:
IOS-DOV or equal
Red Cover
Sensor: CI-305 / Power pack:
BZ-150 or equal
L5-30R
Walker: 880-W2 box, 827PCC-BLK flange, (1)
829PSTC-BLK
data plate, (1)
828PR-BLK recep plate
3/4" Conduit stubbed above ceiling
Future inlet
Broan: 671 or equal
Honeywell:
TH6320U2008
120/240V 60 HZ. single phase
MC Cable/flex
120/240v 1PH 125 amp panel w/ 125 amp main breaker. Exterior NEMA 3R mounted 36" a.f.f. to top (Factory standard) 120/240v 1PH 200 amp panel w/ 200 amp main breaker. Exterior NEMA 3R mounted 36" a.f.f. to top (Factory standard) 2'x4' Flat panel LED 6500 lumens recessed lay-in with dimmable electronic ballast (Factory standard) 2'x2' Flat panel LED 3900 lumens recessed lay-in with electronic ballast (Factory standard)
10W LED porch light with photocell mtd. 82" a.f.f.
24W Surface mounted 1800 lumen LED light (Factory standard) 15a/120v Standard single toggle w/ cover plate mtd. 46" a.f.f. (Factory standard) 15a/120v 3-Way wall mtd. single toggle w/ cover plate mtd. 46" a.f.f. (Factory standard) 20a/120v Wall mtd. occupancy / vacancy sensor w/ cover plate mtd. 46" a.f.f.
20a/120v Single toggle switched to 20a/120v GFCI protected 'WR' rated weatherproof heat tape receptacle mtd. below floor / switch mtd.
46" a.f.f. (Factory standard)
Ceiling mounted occupancy sensor w/ power pack
20a/120v Duplex w/ cover plate mtd. 18" a.f.f.
(Factory standard) 20a/120v GFCI protected w/ cover plate mtd.
42" a.f.f. (Factory standard) 20a/120v GFCI 'WR' rated exterior receptacle with weatherproof in-use cover mtd. 18" a.f.f. (Factory standard) 20a/120v Dedicated Duplex w/ cover plate mtd. 18" a.f.f. (Factory standard) 20a/120v Dedicated GFCI duplex w/ cover plate mtd. 42" a.f.f. (Factory standard) 30a/120v Sng. for water heater w/ cover plate mtd. 18" a.f.f. (Factory standard)
20A/120V 2-Gang wood floor mtd. box w/ (1) duplex recep and (1) phone/data and 3/4" conduit stubbed below floor
4x4 Empty box w/ sngl. gang mud ring, and blank cover plate mtd. 18" a.f.f. for future phone/date (Factory standard) 6x6x6 Empty semi-recessed NEMA-3R box w/ metal cover and 1" conduit stubbed and pull stringabove ceiling mtd. 18" a.f.f.
(Factory standard) 35a/240v 4x4 Wired box w/ sng gang mud ring and cover plate for water heater mtd. 18" a.f.f. (Factory standard) 30a/120v 4x4 Wired box w/ sng gang mud ring and cover plate mtd. at rafters (Factory standard) 30a/120v 4x4 Wired box w/ sng gang mud ring and WR cover plate mtd. 18" a.f.f.
(Factory standard)
70 CFM Ceiling mounted / vent thru wall
Programmable T-Stat(s) mtd. 46" a.f.f.
Color to be: (WHITE) / Exterior device(s) and mansonry boxes with metal cover plate as applicable
NOTE:
1. ALL A.F.F. DIMENSIONS ARE TO THE CENTER OF THE DEVICE BOX UNLESS
NOTED OTHERWISE (REFER TO SCHEDULE AND PLANS FOR HEIGHTS).
2. ALL ELECTRICAL ITEMS ARE FACTORY STANDARD UNLESS NOTED
OTHERWISE.
3. BLANK COVERS WILL BE PROVIDED ON J-BOXES UNLESS NOTED OTHERWISE.
4. ALL EXTERIOR ELECTRICAL DEVICES TO BE WEATHERPROOF.
MODULE ( )1
HC
HC
DUAL
W H
IM
IM
HVAC
2,4A
HVAC
2,4B
HVAC
2,4C
HVAC
2,4D
HVAC
2,4E
HVAC
2,4F
PANEL A PANEL B PANEL C PANEL D PANEL E PANEL F
MODULE ( )2 MODULE ( )3 MODULE ( )4 MODULE ( )5 MODULE ( )6
O
O O
OOOO
O O O O O O
H
HT
7F
GFCI
3F
GFCI
3F
11F
DED
GFCI
15FDED
GFCI
7A
DED
9A
DED
3A
3B3B3A
3A
3A 3B 3B
3B
3B3A
3B
3C
3C
3C
3C
3D
3D
3D
3E
3E
3E
3E
3F
3F
3F
5A
5A
5A
5A
5A
5B
5B
5B
5B
5C
5C
5C
5C
5D
5D
5D
5D
5E
5E
5E
5E
3F
3F
3F
3A 3C 3D 3E
5B 5D 5E
GFCI
WR
3A
GFCI
WR
3C
GFCI
WR
3E6
3D
13FDED
GFCI
10F
6,8F
PC
1C
PC
1C
PC
1C
T T T T
T
9F
DED
GFCI
+18"
E 12F
1'-10"
7' -1
1 ELECTRICAL PLAN
1/4"=1'-0"
OF
W . M
A D
IS
O
N S
T.
PH
O
EN
IX
, A Z
PH
-4
-6
X
-4
-6
SU
N
B
EL
T M
O D
U
LA
R
IN
C
SHEET:
THESE DRAWINGS
REMAIN THE PROPERTY
OF PHOENIX MODULAR
AND ARE NOT TO BE
USED IN ANYWAY
WITHOUT WRITTEN
PERMISSION.
DEALER:
PACIFIC MOBILE
STRUCTURES
PROJECT:
OFFICE (WET)
STATES:
AZ
SERIAL NUMBERS:
PMI-6333-7260
DRAWN BY:
RQ/CK
PLOT DATE:
6/10/2024
REV # / DATE:
MODEL NUMBER:
PH
O
EN
IX M
OD
UL
AR
PMI-PMS-7260 AZ
© 2024
SHAYLON VAUGHN, P.E.
CORPORATE ENGINEER
5301 W. MADISON ST.
PHOENIX, AZ 85043
(602) 447-6460
INDICATES T-GRID
SUSPENDED CEILING
INSTALLED @ FACTORY
INDICATES SUSPENDED
CEILING HOLD-BACK @
MATELINES, TO BE
COMPLETED ON-SITE
BY OTHERS
CEILING LEGENDMODULE ( )1
HVAC HVAC HVAC HVAC HVAC HVAC
PANEL A PANEL B PANEL C PANEL D PANEL E PANEL F
MODULE ( )2 MODULE ( )3 MODULE ( )4 MODULE ( )5 MODULE ( )6
1'-3" 7" 1'-1" 9"
11" 11" 1'-1"9"
7" 1'-3"
4"
50W
1B
50W
1B
50W
1C
50W
1D
50W
1E
50W
1F
50W
1B
50W
1B
50W
1C
50W
1D
50W
1E
50W
1F
1F
1F 30W
1F 30W
1'-6"
1'-6"
6"
1' -4
/8
2'
-6
/8
1'-2 1/2"
OCC OCC OCC
OCC
O
O O
OOOO
OCC
O O O O O O
2' -3
/8
2' -3
/8
2' -3
/8
2' -3
/8
2' -3
/8
2' -3
/8
A B C
A B C
H
70 CFM
1F
70 CFM
1F
PC
PC
PC
T T T T T
T
50W
1C
A
50W
1C
A
50W
1C
A
50W
1C
A
50W
1C
A
50W
1C
A
50W
1C
B
50W
1C
B
50W
1C
B
50W
1C
B
50W
1C
B
50W
1C
B
50W
1C
C
50W
1C
C
50W
1C
C 50W
1C
C
20 6A
20 8A
20 10A
20 12A
20 6B
20 8B
20 10B
20 12B
206E
208E
2010E
2012E
1 REFLECTED CEILING PLAN
1/4"=1'-0"
OF
W . M
A D
IS
O
N S
T.
PH
O
EN
IX
, A Z
PH
-4
-6
X
-4
-6
SU
N
B
EL
T M
O D
U
LA
R
IN
C
SHEET:
THESE DRAWINGS
REMAIN THE PROPERTY
OF PHOENIX MODULAR
AND ARE NOT TO BE
USED IN ANYWAY
WITHOUT WRITTEN
PERMISSION.
DEALER:
PACIFIC MOBILE
STRUCTURES
PROJECT:
OFFICE (WET)
STATES:
AZ
SERIAL NUMBERS:
PMI-6333-7260
DRAWN BY:
RQ/CK
PLOT DATE:
6/10/2024
REV # / DATE:
MODEL NUMBER:
PH
O
EN
IX M
OD
UL
AR
PMI-PMS-7260 AZ
© 2024
SHAYLON VAUGHN, P.E.
CORPORATE ENGINEER
5301 W. MADISON ST.
HVAC:
Symbol Type Qty Note Description
HVAC HVAC Unit
Duct Sleeve
Return Air Plenum
Fiberglass Duct
Fiberglass Duct
Fiberglass Duct
Fiberglass Duct
Supply Diffusers Supply
Diffusers Supply
Diffusers
R/A Grille
R/A Grille
R/A Grille
Duct type
Misc
FAD
10"
6"
8"
8"
8"
12"
3 Ton AC with 10kw heat strip (11 EER) end mount unit / Model: W36AB-A10X or equal
29"x9" To 22"x10" Galvanized sleeve, 16" long
32"x7" Return air plenum w/ 28"x14"x6" tap-in
16"x10"x10'-0" long Fiberglass
22"x10"x10'-0" long Fiberglass
16"x10"x5'-0" long Fiberglass
22"x10"x5'-0" long Fiberglass
24" x 24" 4-way throw diffuser with start collar, collar w/ scoop and damper, and flex (Factory standard) 24" x 24" 4-way throw diffuser with start collar, collar w/ scoop and damper, and flex (Factory standard) 24" x 24" 4-way throw diffuser with start collar, collar w/ scoop and damper, and flex (Factory standard)
(2) 24" x 24" Perforated lay-in with collar and flex (Factory standard) 24" x 24" Perforated lay-in with start collar, collar, and flex (Factory standard) 24" x 24" Perforated lay-in with start collar, collar, and flex (Factory standard) R-6 Fiberglass insulation. Flex air connector not to exceed 14'. Flexible air duct not limited in length.
HVAC ventilation system(s) shall be balanced at site by others.
MODULE ( )1
HVAC HVAC HVAC HVAC HVAC HVAC
PANEL A PANEL B PANEL C PANEL D PANEL E PANEL F
MODULE ( )2 MODULE ( )3 MODULE ( )4 MODULE ( )5 MODULE ( )6
50W 50W 50W 50W 50W 50W
50W 50W 50W 50W 50W 50W
30W
30W
OCC OCC OCC
OCC
OCC
A B C
A B C
70 CFM
70 CFM
TS-3 TS-3 TS-3 TS-3 TS-3 TS-3
x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1 x1
8"
10"
10"
8"
8"
10"
10"
8"
8"
12"
8"
12"
8"
10"
10"
8"
10"
10" x1
12" 12"
8" 8" 8"
12"
8"
8"
6"
6"
8"
8"
10"
10"
T T T T T 12"
T
50W
50W
50W
50W
50W
50W
50W
50W
50W
50W
50W
50W
50W
50W
50W 50W
5'-4" 9'-4 1/2" 5'-10" 9'-7 3/4" 5'-10" 9'-8 1/2" 5'-10" 9'-10 1/2" 5'-10" 10'-0 1/2" 6'-3"2'-3 1/2"
8" 8" 8" 8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
1 HVAC PLAN
1/4"=1'-0"
OF
W . M
A D
IS
O
N S
T.
PH
O
EN
IX
, A Z
PH
-4
-6
X
-4
-6
SU
N
B
EL
T M
O D
U
LA
R
IN
C
SHEET:
THESE DRAWINGS
REMAIN THE PROPERTY
OF PHOENIX MODULAR
AND ARE NOT TO BE
USED IN ANYWAY
WITHOUT WRITTEN
PERMISSION.
DEALER:
PACIFIC MOBILE
STRUCTURES
PROJECT:
OFFICE (WET)
STATES:
AZ
SERIAL NUMBERS:
PMI-6333-7260
DRAWN BY:
RQ/CK
PLOT DATE:
6/10/2024
REV # / DATE:
MODEL NUMBER:
PH
O
EN
IX M
OD
UL
AR
PMI-PMS-7260 AZ
© 2024
SHAYLON VAUGHN, P.E.
CORPORATE ENGINEER
5301 W. MADISON ST.
7' -1
0" C
EI
LI
N G
H
EI
G H
T
4'-0" MAX
60'-0" FLOOR LENGTH
" P
EA
K
STEEL CLEARSPAN
GRADE
2' -1
0"
1/ 2"
M
IN
. S
TU
D H
T.
/1 6"
M
AX
S
TU
D H
T.
B
1/
4"
'-7
1/
" S
H
IP
PI
N
G H
EI
G
H T
W / P
LU
M
BI
N
G V
EN
T
3/4" T&G PLYWOOD
DECKING
1/2" VCG OVER 2X6
EXT. STUDS @ 16" O.C.
2X8 FLOOR JOISTS
@ 16" O.C.
7/16" LP SMART
PANEL SIDING OVER
BARRICADE WRAP
1/2" VCG OVER 2x4 INT.
STUDS @ 16" O.C.
SUSPENDED LAY-IN
CEILING @ 7'-10" A.F.F.
R-38C UNFACED
INSULATION
2X10 RAFTERS12"
1/4"
R-30 USING (2) LAYERS
OF R-15 UNFACED BATT
EPDM ROOFING
R-21 KRAFT FACED
INSULATION
/2
H
EE
L
9"
12"
1/4" 11'-9 1/2" BUILDING HEIGHT
ADDED 2x4 RUNNER
8' FROM EACH END
7/16" LP
SIDING
26ga 2x2 CORNER
(GALVANIZED)
4"x7/16 LP TRIM
3/8" OSB
(ENDWALL ONLY)
6"x7/16" LP TRIM 2x8 END JOIST
FLOOR SHEATHING
WALL STUDS
@ 16" oc
7/16"
LP
SIDING
26ga
'Z' FLASHING
2X6 BOTTOM
PLATE 2
1/ 4"
1"
2"
7/16"
3/ 4"
BARRICADE WRAP
BOTTOM BELLY
WINDOW
FASTENING
VULKEM 116
SEALENT
WINDOW FRAME
SMART PANEL
SIDING
1/2" V.C.G.
2X6
STUDS
STRUCTURAL
HEADER
81" A.F.F.
4"x7/16" L.P.
TRIM
26 GA.
FLASHING
2" 1"
BEND
FLASHING
DOWN
SEALANT
VULKEM 116
SEALENT
PUTTY TAPE
STEP 1
STEP 2 STEP 3
1/
2"
EPDM ROOFING
J-RAIL
8" L.P. TRIM
7/16" L.P.
SMART PANEL
4" L.P. TRIM (TO EXTEND
UNDER ROOF EDGE
AND J-RAIL)
2"
VULKEM 116
SEALENT
2x TOP PLATE 2x RIM RAFTER
7/16" FILLER
ROOF SHEATHING
ROOF DECK
EPDM
LAP SEALANT
GROMMETED HEX
HEAD SCREW
7/16" L.P.
8"x7/16" L.P.
TRIM
GROMMETED
HEX HEAD
SCREW
PUTTY TAPE
J-RAIL
1" 1/2"
1/4"
PLUMBING
VENT
PREMOLDED
EPDM PIPE BOOT
CLAMPING RING
LAP SEALANT
6" M
IN
LAP
SEALANT
BUTYL TAPE
TAPE PRIMER
ROOF UNDERLAYMENT EPDM
MEMBRANEROOF SHEATHING
TOP TRIM (SHIP LOOSE
& SITE INSTALLED
OVER TENSION TIE)
TENSION TIE (SHIP LOOSE
& SITE INSTALL)
4" L.P. TRIM (SHIP LOOSE
& SITE INSTALLED)
J-RAIL
(FACTORY
INSTALLED)
M O
D U
LE
LI
N E
6" L.P. TRIM
(FACTORY
INSTALLED)
1'-6" 1'-6"
J-RAIL (SHIP LOOSE
& SITE INSTALLED
OVER TRIM)
WALL FINISH
VALUE
(LBS)STRAP TYPE FASTENERS
SIMPSON 'ST2215'
(20) 10d NAILS
(0.148"Ø x 1-1/2") 1791#
HEADER
(1)
KI
NG
WALL BOTTOM PLATE
FLOOR SHEATHING
FLOOR JOIST
DBL TOP PLATE
SILL
(1)
TR
IM
(1)
KI
NG
(1)
TR
IM
ADDITIONAL STUD FOR
WALL FINISH (TYP)
END
RAFTER
RAFTER
FASTEN W/ (2)
3"x0.131Ø
COMMON NAIL
EACH END
2x6 BLOCKING (TYP.
EACH END OF ROOF)
2x4
RUNNER
DBL. TOP
PLATE
2x EXT. STUD
FASTEN BLOCKING W/ (2)
3"x0.131Ø COMMON NAIL
EACH END
FASTEN 2x4
RUNNER W/ (2)
3"x0.131Ø
COMMON NAIL
EACH RAFTER
(TYP)
1 BUILDING CROSS SECTION
1/4"=1'-0"
OF
W . M
A D
IS
O
N S
T.
PH
O
EN
IX
, A Z
PH
-4
-6
X
-4
-6
SU
N
B
EL
T M
O D
U
LA
R
IN
C
SHEET:
THESE DRAWINGS
REMAIN THE PROPERTY
OF PHOENIX MODULAR
AND ARE NOT TO BE
USED IN ANYWAY
WITHOUT WRITTEN
PERMISSION.
DEALER:
PACIFIC MOBILE
STRUCTURES
PROJECT:
OFFICE (WET)
STATES:
AZ
SERIAL NUMBERS:
PMI-6333-7260
DRAWN BY:
RQ/CK
PLOT DATE:
6/10/2024
REV # / DATE:
MODEL NUMBER:
PH
O
EN
IX M
OD
UL
AR
PMI-PMS-7260 AZ
© 2024
SHAYLON VAUGHN, P.E.
CORPORATE ENGINEER
5301 W. MADISON ST.
PHOENIX, AZ 85043
(602) 447-6460
A SIDEWALL FINISH
1 1/2"=1'-0" AT CORNER - TYP. B SIDEWALL FINISH
1 1/2"=1'-0" AT FLOOR - TYP. C WINDOW HEADER - TYP.
1 1/2"=1'-0" D ROOF EDGE J-RAIL
1 1/2"=1'-0" E ROOF TRIM
1 1/2"=1'-0" AT CORNER - TYP.
3 PLUMBING VENT
1 1/2"=1'-0" FACTORY INSTALLED2 ROOF DIAPHRAGM MODLINE CHORD TIE
1" = 1'-0" 4 WINDOW FRAMING TYP.
3/4"=1'-0" 5 BLOCKING AT END MEMBER
3/4"=1'-0"
SIGN
8" (7/16") LP TRIM
(BOTTOM HORIZONTAL)
HOOD
Z-BAR ONLY
(INTERMEDIATE HORIZONTAL)
4" (7/16") LP TRIM
(CORNER)
BODY
8" (7/16") LP TRIM
(TOP HORIZONTAL)
DEALER SIGN
(TYP. 4)
SIGN
DEALER SIGN (PROVIDED BY
DEALER & INSTALLED @
FACTORY)
ALL CAULKING TO BE VULKEM 116
HATCHING DENOTES
SHIPLOOSE TRIM
A
B
D C
ELEC. PANEL A
WP GFCI RECEP
(TYP. 3)
ELEC. PANEL BELEC. PANEL CELEC. PANEL DELEC. PANEL EELEC. PANEL F
6x6 INLET BOX
SIGN
SIGN
PORCH LIGHT
(TYP. 3)
4" (7/16") LP
DOOR TRIM
4" (7/16") LP
WINDOW TRIM
'-9
/2
" B U
IL
D
IN
G
H
EI
G H
T W
/ P
LU
M
BI
N G
V
EN
T
14'-7 11/16" SHIPPING HEIGHT
12"
1/4" 12"
1/4"
SIGN
EXHAUST FAN
(TYP. 2)12"
1/4" 12"
1/4"
SB36B27
1'-6"
SIDE B
3'-2 7/8"5'-5"
7'-10"
GFCI RECEP
(TYP 2)
B36
4'-6 1/2" 3'-1"
2' -9
/4
7'-10"
GFCI RECEP
A ELEVATIONS
1/4"=1'-0"
OF
W . M
A D
IS
O
N S
T.
PH
O
EN
IX
, A Z
PH
-4
-6
X
-4
-6
SU
N
B
EL
T M
O D
U
LA
R
IN
C
SHEET:
THESE DRAWINGS
REMAIN THE PROPERTY
OF PHOENIX MODULAR
AND ARE NOT TO BE
USED IN ANYWAY
WITHOUT WRITTEN
PERMISSION.
DEALER:
PACIFIC MOBILE
STRUCTURES
PROJECT:
OFFICE (WET)
STATES:
AZ
SERIAL NUMBERS:
PMI-6333-7260
DRAWN BY:
RQ/CK
PLOT DATE:
6/10/2024
REV # / DATE:
MODEL NUMBER:
PH
O
EN
IX M
OD
UL
AR
PMI-PMS-7260 AZ
© 2024
SHAYLON VAUGHN, P.E.
CORPORATE ENGINEER
5301 W. MADISON ST.
PHOENIX, AZ 85043
(602) 447-6460
B ELEVATIONS
1/4"=1'-0"
C ELEVATIONS
1/4"=1'-0"
D ELEVATIONS
1/4"=1'-0"
1 CABINET ELEVATIONS
1/2"=1'-0"
2 CABINET ELEVATIONS
1/2"=1'-0"
| Sheets and Views |
| PMI-6333-7260 (AZ)-Plot-SPEC-D |
| PMI-6333-7260 (AZ)-Plot-FLR-D |
| PMI-6333-7260 (AZ)-Plot-ELEC-D |
| PMI-6333-7260 (AZ)-Plot-RCP-D |
| PMI-6333-7260 (AZ)-Plot-HVAC-D |
| PMI-6333-7260 (AZ)-Plot-X-SECT-D |
| PMI-6333-7260 (AZ)-Plot-ELEVS-D |
File details come from the government source that posted it. Updated .