Attachment_4_Drawing.pdf
PDF 3 MB Posted
- Attached to
- B2000 L11, L12 Bathroom Renovation
- Solicitation number
- F2MTLG6061AW01_Bathroom_Renovation
About this file
Attachment 4 Drawing
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sign_In_Sheet.PDF | ||
| Building_2000_Question_Answered.docx | DOCX document | |
| A-103_Revised_12_Sep_16.pdf | ||
| Directions_to_Bldg_2000.pdf | ||
| Wage_Determinatio.docx | DOCX document | |
| FA3016-16-R-0093-0001_(01).pdf | ||
| Attachment_1_Statement_of_Work.docx | DOCX document | |
| Attachment_6_As_Builts.pdf | ||
| FA3016-16-R-0093.pdf | ||
| Attachment_9_Local_Requirements.docx | DOCX document | |
| Attachment_2_Div_01 _08 _09 _10 _21 _22 23 _26.pdf | ||
| Attachment_7_-_Wage_Determination_TX160280.docx | DOCX document | |
| Attachment_8_Administrative_Authority.docx | DOCX document | |
| Attachment_5_Asbestos_Survey.pdf | ||
| Attachment_3_Submittal_Register_2.pdf | ||
| Presolicitation_Notice.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SAN ANTONIO
MEDINA RIVER
SAN
A N
TO
N
IO
RIVER
GUADALUPE
CREEK
GUADALUPE
RIVER
GUADALUPE
SAN
MARCOS
RIVER
C
IBO
LO
CREEK
KENDALL
UADALUPE
RIVER
BALCONES
CREEK
CIBOLO
WILSON
SAN
A N
TO
N
IO
C
IBO
LO
CREEK
BEXAR
COMAL
ATASCOSA
CALAVERAS
LAKE
Kelly AFB
Lackland AFB Brooks AFB
Randolph AFB
International Airport San Antonio
New Braunfels
Seguin
Stockdale
Boerne
CANYON LAKE
REC. AREA
FORT SAM
HOUSTON
CAMP
BULLIS
12031
12039
15041
12049
15060
10265
10504
12012
12028
15036
13028
15062
13034
15049
P956
15024
15045
15062
13067
10055
12042
15006
13032
15030
15055
12047
Pavilion 3
10207
13014
10395
N/A
12038
15057
12013
10330
13020
15007
15003
10253
13000
N/A
10345
Pavilion 2
13060
13004
15060
15012
N/A
10007
13052
15037
13016
15014
15007
12003
15019
15001
12048
12017
15088
15004
15053
13054
15064
15088
15006
15065
10250
12046
12006
15063
15032
12008
N/A
15012
15059
13023
15002
12033
13017
15058
13059
13005
15000
15028
15048
13007
10390
13030
15040
N/A
16041601
15003
N/A
12004
13015
15054
13006
15005
10175
15031
15027
10065
13055
13025
13027
12009
12016
12045
15051
12025
13058
12019
N/A
12024
N/A
15009
13063
12020
15052
10215
15047
12043
13013
10070
N/A
13051
10060
13021
10263
15015
15009
12023
15065
P958
10251
N/A
12005
12021
15018
N/A
15058
12026
12044
15010
12010
15056
12040
10380
15050
15055
15009
15063
13056
15033
13018
15042
13001
12014
N/A
12000
15017
15061
15043
15023
13065
12022
12036
10210
13053
P957
15060
15007
10255
10203
15015
N/A
15046
13029
12001
15088
13057
12011
15022
13002
12018
15064
10205
15058
15029
15038
10375
15025
15021
10230
10416
12027
15001
13047
10346
Pavilion 1
10385
10201
13022
15056
15026
15005
15061
13033
15010
13031
12015
15012
15044
12032
13061
13026
13008
10050
12050
12007
10338
12034
15059
12041
12002
13012
10261
12030
12037
15056
15013
10075
15020
15006
15004
15002
10056
13003
13019
10501
15063
13050
15057
15003
15003
130491618
15064
15034
16231623
15039
15064
12029
15007
12035
13024
13045
M
ILITAR
Y
DR
G A
R Y
AV
E
TBD
Kelly Drive
SCOTT DR
Chappie James Way
Moore Street
Hof Street
TBD
ARN
O
LD
CIRCLE
G
EO
RG
E
AVE
CHELI LN
MC GUIRE ST
KISSLING COURT
TBD
Se cu rit y
Hi ll
TBD
MILITARY DR
CAR
SW
ELL
AVE
GOTT ST
TBD
PATRICK ST
M
ILITAR
Y
DR
KE
LL
AC
K
ST
TBD
BAR
NES
AVE
TBD
TBD
PEASE ST
LUKE BLVD
TBD
M
ILITAR
Y
DR
H
UG
H
ES
AVE
Andrews Road
PATRICK ST
TBD
La ve ne Lo op
TB
D
G
ARY
AVE
TBD
KEN
LY
AVE
ENT CIR
GOODFELLOW ST
TRUEMPER
ST
MEIVOHER DR
BAR
NES
AVE
Blake Road
H al l S tre et
HARLOW
ST
TBD
BERGQUIST DR
LARSON ST
M
ILITAR
Y
DR
Warner Circle
G
EO
RG
E
AVE
Billy Mitchell Road
Ch ap m an
Ci rc le
H angar W ay
W
ALKER
AVE
WURTSMITH ST
AND
REW
S
AVE
CONNALLY ST
SELFRIDGE BLVD
PATRICK ST
LUKE BLVD
G
EO
R G
E
AV
E
BO
NG
AVE
TBD
HUGHES
AV
E
W
ALKER
AVE
BO
N
G
AVE
ERWIN CIRCLE
PUCKET ST
KEESLER
AVE
G
ARY
AVE
TRUEMPER ST
MC CHORD ST
Wakkana Street
Peshawar Street
Ki rk ne wt on St re et
TBD
Kelly Drive
OLMSTED ST
M C
DILL
DR
BERGQUIST DR
W
ALKER
AVE
TIN
KER
ST
LADD ST
Y O
U N
T
PEPPERRELL ST
TBD
SELFRIDGE BLVD
TBD
TBD
B
IG
G S
AV
E
STEWART ST
TB
D
FERSON LOOP
SARNOSKI ST
G
EO
RG
E
AVE
SARNOSKI ST
TB
D
TBD
GENTILE ST
HARMON DR
M
ETZG
ER
DR
HENSLEY ST
FIVE
PALM
S
DR
Sarnoski Street
TB
D
FEMOYER ST
FO
STER
AVE
PEASE ST
KIRTLAND ST
Bullard
C
RAW
AVE
SE
RV
IC
E
RD
R
LEM
AY
TBD
M athies
Court
Fegan Loop
LUKE BLVD
KELLY DR
Bl ak e R oa d
D
IM
S
TE
AD
AV
E
C
ASTLE
AVE
FAIR
C
H
ILD
ST
H al l S tre et
M C
DI
LL
DR
Ha ll S tre et
HU
G
H
ES
AVE
TIN
KER
AVE
TBD
PATRICK ST
TBD
B O
N G
AVE
TRUEMPER ST
BO
NG
AVE
HARM
O
N
DR
TB
D
TBD
H O
LLO
W
M
AN
ST
TBD
HENSLEY ST
TB
D
TBD
Kelly Drive
GENTILE ST
C
RAW
AVE
TBD
H
UG
H
ES
AVE
VANCE ST
NELLIS ST
RAN
GE
RD
TBD
D
IM
S
TE
AD
AV
E
Trabzon Street
SELFRIDGE BLVD
CONNALLY ST
MAXWELL ST
KNIGHT ST
SELFRIDGE BLVD
TBD
ARIZONA ST
SELFRIDGE AVE
TBD
REESE ST
FEMOYER ST
W
ILFO
RD
HALL
LO
O
P
RENOVATE RESTROOM
L11 AND L12 BLD2000
JBSA - LACKLAND AFB, KELLY ANNEX
Scale: N.T.S
REGIONAL MAP
Scale: N.T.S
VISITOR'S
CENTER
FOR BASE
PASS
(LUKE ST)
PROJECT
LOCATION
DRAWING INDEX
SHEET ID SHEET TITLE
GENERAL
G-001 COVER SHEET
ARCHITECTURAL
A-101 DEMO EXISTING-NEW FLOOR PLAN
A-102 REFLECTED CEILING EXST - NEW
A-501 DETAILS
A-502 DOOR FRAME DETAILS
A-901 EXISTING CONDITION PHOTOS
Electrical
E-101 PANEL LOCATION
E-102 EXISTING ELECTRICAL L11 AND L12
E-901 ALARM DEVICES
Plumbing
P-501 PLUMBING DETAILS
P-901 TUNNEL ACCESS POINT
G-001
G E
N E
R A
L C
O V
E R
S H
E E
T
G B
C H
E C
K E
D B
Y
G B
KELL150019
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
JB
S
FX
XX
XX
X-
G -0
.d w g
R G
H
JOINT BASE SAN ANTONIO
LACKLAND AFB KELLY
ANNEX
502d CIVIL ENGINEER SQ.
SAN ANTONIO, TX
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
GATE FOR APPROVED
ID/BASE PASS HOLDER
LACKLAND AFB KELLY ANNEX
FA3016-16-R-0093 ATTACHMENT 4
A-101
A R
C H
IT
E
C
TU
R A
L D
E M
O E
X
IS
TI
N
G -N
E W
F
LO
O R
P
LA
N
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
D E
M O
.d w g
R G
H
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
SCALE: 14" = 1'-0"
0 2' 4' 12'8'
SCALE: 3
8" = 1'-0"A1 DEMO
KELL150019
CONTRACTOR SHALL REMOVE
THE ITEMS 1-11 OFF LACKLAND
AFB (KELLY ANNEX) AND
DISPOSE OF OF ACCORDING TO
JBSA, LOCAL, CITY, STATE AND
FEDERAL REGULATIONS.
a. CERAMIC FLOOR TILE AND
CEMENTITIOUS SETTING
MATERIAL.
b. CERAMIC WALL TILE AND
SETTING MATERIAL.
c. TOILET PARTITIONS
d. URINALS
e. TOILETS
f. LAVATORIES AND COUNTER
TOP
g. DOOR AND METAL FRAMES
h. CMUWALL FROM FLOOR TO
CEILING WHERE HATCHED
MIRRORS AND SUPPORTS
i. MIRRORS AND SUPPORTS
j. ACOUSTICAL CEILING, SUPPORTING GRID AND BATT
INSULATION.
1. DEMO VANITIES, MIRRORS
AND ASSOCIATED
HARDWARE.
2. DEMO PARTITIONS AND
URINAL SCREENS.
3. DEMO DOORS, FRAMES AND
ASSOCIATED HARDWARE
4. DEMO CARPET AND CERAMIC
FLOORING.
5. DEMO TOILETS AND URINALS.
6. DEMO RAILING FOR NEW
DOOR OPENING AS
REQUIRED.
7. AUTOMATIC DOOR
OPERATOR.
1. THE WORD "PROVIDE" OR
PROVIDED" WHEN REFERRING TO
CONSTRUCTION ELEMENTS OR
EQUIPMENT ON THE CONTRACT
DRAWINGS SHALL BE UNDERSTOOD
TO MEAN, CONTRACTOR SHALL
SUPPLY ITEM INDICATED AND
INSTALL ACCORDING TO
MANUFACTURES PRINTED
INSTRUCTIONS, CODE
REQUIREMENTS, STANDARD
INDUSTRY PRACTICES AND JOB
SPECIFICATIONS, TO BE COMPLETE
AND FULLY FUNCTIONAL FOR ITS
INTENDED PURPOSE, WITH NO
ANCILLARY CONSTRUCTION OR
OTHER WORK REQUIRED TO BE
PERFORMED BY THE GOVERNMENT.
2. JC = JANITORS CLOSET
SCALE: 1
4" = 1'-0"A2 NEW
1 1
CONTRACTOR SHALL PROVIDE THE FOLLOWING.
1. ADA COMPLIANT WATER CLOSET.
2. STRUCTURAL SUPPORT SHALL BE PROVIDED
FOR ALL GRAB BARS USE HEAVY DUTY TYPE
GRAB BARS.
3. NEW RAILING AS REQUIRED.IN HALLWAY.
FINISHES SHALL MATCH EXISTING STYLE AND
MATERIALS.
4. FLOOR MOUNTED MOP SINK.
5. ADA COMPLIANT VANITY, SINK AND FIXTURES.
a. FINISHES SHALL MATCH EXISTING COLORS
AND PATTERNS.
b. CONTRACTOR SHALL SUBMIT COLOR AND
MATERIAL SAMPLES FOR SELECTION BY
BUILDING USER.
c. CONTRACTOR SHALL COORDINATE WITH BLDG
USER TO VERIFY THAT NEW RESTROOM
ACCESSORIES AND BE ACCESSED AND
MAINTAINED BY BUILDING JANITORIAL STAFF.
d. THE CONTRACTOR SHALL COORDINATE ALL
PHASE OF WORK TO INCLUDE ESCORT
SCHEDULING, MATERIAL DELIVERIES AND
UTILITY OUTAGES.
RM 101
RM 101
A-102
A R
C H
IT
E
C
TU
R A
L R
E
FL
E C
TE
D
C E
IL
IN
G E
X S
T
- N
E W
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
R E
FL
E
C
TE
D C
E
IL
IN
G
E X
S T
- N E
W .d w g
R G
H
A6
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
SCALE: 14" = 1'-0"
0 2' 4' 12'8'
SCALE: 1
4" = 1'-0"A4 REFLECTED CEILING - NEW
KELL150019
1. LOCATIONS OF EXISTING FIXTURES,
CEILING TYPES AND FIRE
ALARM/SUPPRESSION DEVICES SHALL BE
FIELD VERIFIED BY CONTRACTOR PRIOR
TO SUBMISSION OF PROPOSAL.
2. LOCATIONS OF FIXTURES SHOWN ON
NEW REFLECTED CEILING PLAN ARE FOR
INFORMATION ONLY. PRIOR TO
CONSTRICTION CONTRACTOR SHALL
SUBMIT A REFLECTED CEILING PLAN
SHOWING ACTUAL LOCATIONS.
RETURN AIR GRILL - DEMO
1. ACOUSTICAL CEILING ASSEMBLY -
REMOVE
2. PLASTER CEILING ABOVE ACOUSTICAL
CEILING - REMOVE
3. PLASTER CEILING - REMOVE
4. EXISTING WINDOWS TO REMAIN IN
EACH SPACE AND PROTECTED FROM
DAMAGE DURING THE PROJECT.
RECESSED FLUORESCENT
LIGHT - NEW
SUPPLY VENT - DEMO
VANITY LIGHTING - DEMO
2 X 2 FLUORESCENT LIGHT FIXTURE
- DEMO
CEILING DIFFUSER
2 X 4 FLUORESCENT LIGHT FIXTURE
- DEMO
FIRE SPRINKLER - PROTECT
SPEAKER
2X4 RECESSED FLUORESCENT
LIGHT - NEW
FIRE SPRINKLER - PROTECT/RE-INSTALL
SPEAKER - PROTECT/RE-INSTALL
SUPPLY VENT - NEW
EXHAUST - NEW
2X2 RECESSED FLUORESCENT LIGHT -
NEW
SIX INCH RECESSED CANNED LIGHT
FLUORESCENT - NEW
SCALE: 1
4" = 1'-0"A3 REFLECTED CEILING - EXISTING
2X4 RECESSED FLUORESCENT LIGHT
WITH BATTERY BACKUP - NEW
1. NEW SUSPENDED GYPSUM CEILING.
A-501
A R
C H
IT
E
C
TU
R A
L D
E
TA
IL
S
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
D E
TA
IL
S .d w g
R G
H
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
KELL150019
1. PHOTO INCLUDED TO ILLUSTRATE
DESIGN INTENT OF CONCEALED
PLUMBING AND UNDERCOUNTER
MOUNTED SINK. ACTUAL COLORS,
FINISHES AND FIXTURES WILL BE AS
INDICATED IN THE SOW.
2. FRAMING DETAIL IS TYPICAL
CONTRACTOR SHALL SUBMIT SHOP
DRAWINGS SHOWING ALL FABRICATED
CASEWORK IN PLAN VIEW, ELEVATIONS
AND CROSS-SECTIONS TO ACCURATELY
INDICATE MATERIALS USED, DETAILS OF
CONSTRUCTION, DIMENSIONS, METHODS
OF FASTENING AND ERECTION, AND
INSTALLATION METHODS PROPOSED.
SHOP DRAWINGS SHALL INCLUDE COLOR
SCHEDULE OF CASEWORK ITEMS TO
INCLUDE COUNTERTOP, EXPOSED, AND
SEMI EXPOSED CABINET FINISHES TO
INCLUDE FINISH MATERIAL
MANUFACTURER, PATTERN, AND COLOR
SOLID POLYMER
MIN 1/2" THICK
ACCESS
PANEL-TYP
RIMLESS UNDER
COUNTER SINK
SCALE: NONEA7 GYPSUM CEILING DETAIL
SCALE: NONEA5 VANITY DETAIL
5/8" GYP WALLBOARD
METAL STUD
5/8" GYP
WALLBOARD
WIRE HANGER
FURRING CHANNELS
@ 4'-0" O.C. MAX
7/8" HAT CHANNELS
@ 24" O.C. MAX
SUSPENDED 5/8" GYP
BOARD CEILING
ADA
A D
A
A D
A
ADA
CEILING HEIGHT
TO MATCH THE
CEILING HEIGHT OF
THE PLASTER CEILING
THAT WAS DEMOLISHED.
FINISHED FLOOR
SCALE: NONE
A6 METAL STUD PARTITION
A-502
A R
C H
IT
E
C
TU
R A
L D
O O
R F
R A
M E
D E
TA
IL
S
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
D O
O R
F R
AM
E
D E
TA
IL
S.
dw g
R G
H
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
SCALE: NONEA8 JAM DETAIL
KELL150019
1. DOOR FRAME DETAILS ARE TYPICAL.
CONTRACTOR SHALL PROVIDE TO THE
CONTRACTING OFFICER THE SHOP
DRAWINGS SHOWING ACTUAL
CONNECTION AND ASSEMBLY DETAILS
PRIOR TO INSTALLATION.
2. DOOR FRAME COLOR SHALL MATCH
EXISTING DOOR FRAME COLORS.
CONTRACTOR SHALL SUBMIT A COLOR
SAMPLE FOR THE BLDG USER TO SELECT
FROM.
SCALE: NONEA9 HEAD DETAIL
STEEL STUDS
OR FURRING
CHANNEL
SEALANT
5/8" GWB EA. SIDE
SOLID WOOD DOOR
RED OAK FINISH
STEEL STUDS
OR FURRING
CHANNEL
SEALANT
METAL DOOR
FRAME
METAL DOOR
FRAME
SOLID WOOD DOOR
RED OAK FINISH
MARBLE
THRESHOLD
TYPICAL
SEALANT
SEALANT
METAL CLIP
MIN 3 PER
SIDE
A-901
A R
C H
IT
E
C
TU
R A
L E
X
IS
TI
N
G C
O N
D
IT
IO
N
P H
O
TO
S
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
K
EL
L1
A -9
.d w g
R G
H
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
SCALE: NONE
EXISTING CONDITION PHOTOS
KELL150019
1. NEW RESTROOM FINSISHES SHALL MATCH
EXISTING COLORS AND PATTERN TYPES.
1 2 3 4
5 6 7 8
9 10 11 12
1. EXISTING JANITORS CLOSET.
2. RESTROOM L12
3. WATER CLOSET
4. EXISTING TOILET
PARTITIONS/AUTOMATIC PAPER TOWEL
DISPENSER
5. RESTROOM L11
6. RESTROOM L11
7. WATER CLOSET
8. RESTROOM L11
9. ELECTRICAL PANEL THAT IS NOT ON
RECORD DRAWINGS LOCATED IN ROOM
101.
10. PANEL SCHEDULE
11. OFFICE 101
12. RESTROOM L11
13. PARTITION WALL BETWEEN L11 AND
OFFICE 101.
E-101
E
LE
C
TR
IC
A
L P
A N
E L
LO
C
A
TI
O N
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
E -1
P
AN
EL
L O
C
AT
IO
N
.d w g
R G
H
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
SCALE: NONEE1 PANEL LOCATION
KELL150019
PANEL NLBA
1. CONTRACTOR SHALL
FIELD VERIFY THAT
EXISTING CIRCUITS ARE
FED BY PANEL NLBA.
PROJECT
LOCATION
PROJECT
LOCATION
PANEL NLBA
S
S
S
S
S
S
E-102
E
LE
C
TR
IC
A
L E
X
IS
TI
N
G E
LE
C
TR
IC
A L
L1
A N
D L
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
E -1
E
XI
ST
IN
G
E
LE
C
TR
IC
AL
L
A N
D L
.d w g
R G
H
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
SCALE: NONEE2 EXISTING ELECTRICAL L11 AND L12
KELL150019
1. CONTRACTOR SHALL VISIT THE PROJECT
SITE AT OWN EXPENSE TO VERIFY
EXISTING CONDITIONS AND ACCURACY
OF RECORD DRAWINGS.
2. IF THERE ARE SIGNIFICANT DIFFERENCES
IN LOCATIONS AND QUANTITIES THEN
WHAT IS SHOWN IN RECORD DRAWINGS
THE CONTRACTOR SHALL NOTIFY IN
WRITING TO THE CONTRACTING OFFICER
WITH IN 7 DAYS.
1. PANEL LBA IS NOW LABLED NLBA AS
INDICATED ON SHEET E-101.
E-901
E
LE
C
TR
IC
A
L A
LA
R
M D
E V
IC
E
S
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
E -9
A
LA
R
M D
EV
IC
ES
.d w g
R G
H
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
SCALE: NONEE3 ALARM DEVICES
KELL150019
1. PRIOR TO START OF CONSTRUCTION
ACTIVITIES CONTRACTOR SHALL
COORDINATE WITH THE CONTRACTING
OFFICER OR DESIGNATED
REPRESENTATIVE TO VERIFY THAT
EXISTING DEVICES ARE FUNCTIONING
PROPERLY.
2. CONTRACTOR SHALL DOCUMENT
OPERATING CONDITION OF EXISTING
DEVICES AND PROVIDE REPORT TO
CONTRACTING OFFICER WITHIN 7 DAYS
AFTER INSPECTION OF ALARM DEVICES.
3. RELOCATE ALARM DEVICES AS
REQUIRED TO COMPLY WITH NEW
RESTROOM LAYOUT.
1. PANEL IS ACTIVE AND SHALL REMAIN IN
PLACE AND FULLY FUNCTIONING
DURING PROJECT.
2. DEVICES LOCATED IN FEMALE
RESTROOM SHALL BE PROTECTED
DURING PROJECT.
3. DEVICES LOCATED IN MALE
RESTROOM SHALL BE PROTECTED
DURING PROJECT.
P-501
P
LU
M B
IN
G
P
LU
M B
IN
G
D E
TA
IL
S
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
P -5
P
LU
M
B
IN
G D
E
TA
IL
S.
dw g
R G
H
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
SCALE: NONEP1 WALL CLEANOUT-FINISHED ROOMS
KELL150019
SCALE: NONEP2 FLOOR DRAINS
POLISHED STAINLESS
STEEL ACCESS COVER
COUNTER SUNK
SCREW
CLEANOUT
PLUG
SLOPE TO
DRAIN
P-901
P
LU
M B
IN
G
TU
N
N E
L A
C C
E S
S P
O
IN
T
G B
C H
E C
K E
D B
Y
G B
R E
N O
V A
TE
R
E S
TR
O
O M
L1
A N
D L
B
LD
JB
S A
LA
C K
LA
N
D A
FB
, K
EL
LY
A N
N
EX
P -9
T
U N
N E
L
AC
C E
SS
P
O
IN
T.
dw g
R G
H
D
2 3 4 5
C
B
A
D at e A
P P
R O
VE
D
A S
-B U
IL
T
A pp ro va l D at e
D es cr ip tio n
R ev
Sheet of
FI
LE
N A
M E
D W
N B
Y
D
ES
IG
N
E D
B Y:
R
EL
EA
SE
D B
Y
C K
D B
Y
W O
R K
O R
D E
R N
U M
B E
R
C O
N
TR
A C
T N
U M
B E
R
D R
A W
IN
G
C O
D E: D A
TE
PROJECT NUMBER
FS
N
-4
D
C
B
A
1 2 3 4 5
BUILD STRONG
502D CIVIL ENGINEER S
Q
SCALE: NONEP3 TUNNEL ACCESS POINT
KELL150019
1 2
TUNNEL ENTRANCE MAIN ACCESS WAY
ACCESS UNDER
RESTROOMS
ACCESS UNDER
RESTROOMS
File details come from the government source that posted it. Updated .