Attachment_1_Statement_of_Work.docx
DOCX document 48 KB Posted
- Attached to
- B2000 L11, L12 Bathroom Renovation
- Solicitation number
- F2MTLG6061AW01_Bathroom_Renovation
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sign_In_Sheet.PDF | ||
| Building_2000_Question_Answered.docx | DOCX document | |
| A-103_Revised_12_Sep_16.pdf | ||
| Directions_to_Bldg_2000.pdf | ||
| Wage_Determinatio.docx | DOCX document | |
| FA3016-16-R-0093-0001_(01).pdf | ||
| Attachment_6_As_Builts.pdf | ||
| FA3016-16-R-0093.pdf | ||
| Attachment_9_Local_Requirements.docx | DOCX document | |
| Attachment_2_Div_01 _08 _09 _10 _21 _22 23 _26.pdf | ||
| Attachment_7_-_Wage_Determination_TX160280.docx | DOCX document | |
| Attachment_8_Administrative_Authority.docx | DOCX document | |
| Attachment_5_Asbestos_Survey.pdf | ||
| Attachment_4_Drawing.pdf | ||
| Attachment_3_Submittal_Register_2.pdf | ||
| Presolicitation_Notice.docx | DOCX document |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
KELL150019
RENOVATE RESTROOM L11, L12 B2000
JOINT BASE SAN ANTONIO – LACKLAND AFB (KELLY ANNEX)
SAN ANTONIO, TEXAS
Date 02 July 2015
FA3016-16-R-0093 ATTACHMENT 2
THIS PAGE IS LEFT INTENTIONALLY BLANK
STATEMENT OF WORK
1. PROJECT NUMBER: KELL150019-44067
2. TITLE: RENV/Renovate Restroom L11 and L12 Building 2000
3. PROJECT LOCATION: Lackland AFB (Kelly Annex)
4. GENERAL DESCRIPTION OF WORK
The scope of this project is to expand the existing restrooms to create the square footage required to meet current federal accessibility standards.
Features of work include the demolition of the existing restrooms, janitor's closet and office 101 to create ADA compliant restrooms. Work elements include at a minimum but not limited to, architectural, electrical and mechanical. The room and door finishes shall match existing colors and patterns to keep with the historic theme of the original building design.
4.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
DoD Unified Facilities Criteria (UFC)
UFC 3-600-01 (26 September 2006) FIRE PROTECTION ENGINEERING FOR FACILITIES Change 3, 1 March 2013
U.S. ARMY CORPS OF ENGINEERS (USACE)
EM 385-1-1 (2008; Errata 2011) Safety and Health Requirements Manual
5. APPLICABLE DETAILED SPECIFICATIONS: DIVISION 1 THROUGH 32 DIVISION 01 GENERAL REQUIREMENTS
| 01 |
| 35 |
| 13.20 |
| 00 |
| SPECIAL PROJECT PROCEDURES- CAD |
| 01 |
| 35 |
| 26 |
GOVERNMENTAL SAFETY REQUIREMENTS
| 01 |
| 35 |
| 35 |
ENVIRONMENTAL PROTECTION
| 01 |
| 42 |
| 00 |
SOURCES FOR REFERENCE PUBLICATIONS
| 01 |
| 45 |
| 00.00 |
| 20 |
| CONTRACTOR QUALITY CONTROL |
| 01 |
| 50 |
| 00 |
TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
| 01 |
| 72 |
| 00.00 |
| 44 |
| ALTERATIONS TO EXISTING FACILITIES |
| 01 |
| 77 |
| 00.00 |
| 20 |
| CONTRACT CLOSEOUT |
| 01 |
| 78 |
| 00 |
CLOSEOUT SUBMITTALS
| 01 |
| 78 |
| 23 |
OPERATION AND MAINTENANCE DATA
| 01 |
| 78 |
| 36.00 |
WARRANTY OF CONSTRUCTION
of
DIVISION 08 OPENINGS
| 08 11 13 | STEEL FRAMES |
| 08 14 00 | WOOD DOORS |
| 8 71 00 | DOOR HARDWARE |
DIVISION 09 FINISHES
| 9 22 00 | SUPPORTS FOR PLASTER AND GYPSUM BOARD |
| 09 29 00 | GYPSUM BOARD |
| 09 30 13 | CERAMIC TILING |
| 9 90 00 | PAINTS AND COATINGS |
DIVISION 10 SPECIALTIES
| 10 21 13 | TOILET COMPARTMENTS DIVISION 22 | PLUMBING | |
| 22 00 00 | PLUMBING, GENERAL PURPOSE |
DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING
| 23 31 13.00 40 | METAL DUCTS | |
| 23 37 13.00 40 | DIFFUSERS, REGISTERS, AND GRILLS DIVISION 26 | ELECTRICAL |
| 26 05 00.00 40 | COMMON WORK RESULTS FOR ELECTRICAL | |
| 26 51 00 | INTERIOR LIGHTING |
6. PERFORMANCE SPECIFICATIONS/DETAILED SCOPE OF WORK:
6.1 Work Plan
Develop a work plan indicating means and methods of the restroom renovation. Plan shall include, at minimum, a narrative describing the work to be performed and supporting documentation to include final construction plans and shop drawings showing plumbing/riser diagrams, electrical one line drawings that show new named circuits and circuits removed and mechanical plans showing connection details.
Work plan shall identify requirements for safety devices, dumpster location(s), and protection of stored material from exposure to weather, protection of property and personnel, building access routes and circulation patterns, contractor use of the premises, parking, security procedures, equipment, materials storage and waste disposal.
6.2 Submittals
Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for Contractor Quality Control approval. The following shall be submitted in accordance with Section 01 33
00 SUBMITTAL PROCEDURES:
SD-01 DATA
Work Plan; G Construction Plans mechanical shop drawings; G electrical shop drawings; G waste/supply piping schematic shop drawings; G
6.3 DEMOLITION
Contractor shall use means and methods to minimize excessive dust and noise. If excessive noise during demolition/construction is unavoidable contractor shall notify the contracting officer or designated government representative within a minimum of 7 (seven) working days in advance to allow for coordination with building manager.
6.3.1 Architectural/Interior See attachment 11.
6.3.2 Structural See attachment 11.
6.3.3 Mechanical
Demo existing exhaust and HVAC duct work to extent required to allow for installation of new work.
6.3.4 Electrical
Prior to start of electrical demo contractor shall trace circuits of the electrical panel in room 101.
6.3.4.1 Fluorescent Lights
Demo existing surface mounted fluorescent and recessed lighting.
6.3.4.2 Switches/Outlets
Demo existing electrical outlets, switches and communication circuits in rooms L11, L12 and room 101.
6.3.5 Plumbing
Demo existing plumbing to include cut-off valves and drains, up to rough-in plumbing.
6.3.6 Environmental
See attached hazardous material surveys dated 17 July 2015 and 1 February 2016.
6.3.7 Fire
Contractor shall follow UFC 3-600-01 26 September 2006 (change 3, 1 March 2013) when work on existing fire protection devices is required as part of this project. UFC can be obtained at http://www.wbdg.org/ccb/DOD/UFC/ufc_3_600_01.pdf
6.3.8 Existing Devices
Existing devices shall remain in place during renovation work. Contractor shall protect devices to prevent damage.
6.4 NEW WORK
Contractor shall supply labor and new materials unless otherwise specified to provide a complete and usable system. Colors, finishes and tile patterns shall match existing. A cover up inspection shall be scheduled by the contractor with the COR prior to installation of flooring, wall and ceiling panels.
6.4.1 Architectural See attachment 11.
6.4.2 Structural See attachment 11.
6.4.3 Mechanical
Install over the door transfer grills at restroom entrances. Contractor shall submit mechanical shop drawings that show the detail of the transfer grill and connecting duct work.
6.4.4 Electrical
6.4.4.1 New Circuits
Use existing conduits for new electrical conductors and components to the extent possible. Contractor shall submit electrical shop drawings that show new one line wiring diagram. See attached drawings for new work.
6.4.4.2 Switches/Outlets
Provide one light switch in each restroom and one GFCI protected convenience outlet.
6.4.5 Plumbing
Where necessary cap abandoned waste piping connection points. Contractor shall submit waste/supply piping schematic shop drawings that show new pipe location and connection details. See attached drawings for new work.
7. PERFORMANCE PERIOD
Project schedule shall be submitted IAW section 01 32 16.00 20 SMALL PROJECT CONSTRUCTION PROGRESS SCHEDULES.
8. SCHEDULING REQUIREMENTS AND HOURS OF OPERATION/DAILY WORK HOURS
The only scheduling of work outside of normal working hours that may be required for this project is during features of work that produce excessive noise, vibration and /or dust. During these types of activities contractor shall coordinate with the designated government representative and building user. Normal work hours are 0730-1700 Monday-Friday, weekend and after hours work shall only be performed by prior approval from contracting officer. The facility will be occupied during this construction period.
Facility is a secure bldg and escorts will be required at all times for contractor/sub-contractor employees. Escorts will be provided by the building user.
9. GOVERNMENT FURNISHED ITEMS None.
10. NOTED CONTRACTOR REQUIREMENTS
10.1 After Award
10.1.1 Shop Drawings
Contractor shall provide construction drawings 30 days after issuance of NTP.
10.1.2 Contractor Quality Control Reports
Contractor shall submit daily (or more often, as applicable) Contractor Quality Control Report (CQC) IAW section 01 45 00.00 20 CONTRACTOR QUALITY CONTROL.
10.1.3 Construction Plans
Contractor shall provide construction plans 30 days after award.
10.1.4 Lay Down Area
Contractor shall coordinate with government representative to determine the location for the project lay down/storage area.
10.2 Debris and Cleanup
Upon completion of the workday, the contractor shall leave the work area in a clean manner. All project generated debris and waste shall be removed from the sire and disposed of at an appropriate location off post.
10.3 Toilet Facilities
Are not available, contractor shall provide a chemical toilet or other facility for crew personnel assigned to the roof repair project.
10.4 As Built Record Drawings
As Built CADD documents IAW section 01 35 13.20 00 SPECIAL PROJECT PROCEDURES-CAD
11. ATTACHMENTS
This scope of work includes the following attachments.
| ATTACHMENT 2 | Div 01, 08, 09, 10, 21, 22, 23, 26 |
| ATTACHMENT 3 | Submittal Register |
| ATTACHMENT 4 | Conceptual Design Drawings |
| ATTACHMENT 5 | Asbestos Survey |
| ATTACHMENT 6 | As Built |
| ATTACHMENT 7 | Wage Determination |
| ATTACHMENT 8 | Administrative Authority |
| ATTACHMENT 9 | Local Requirements |
-- End of Section --image1.jpeg