EXHIBIT IIB_Portals_Permit_Set.pdf

PDF 4 MB Posted

Attached to
USHMM Classrooms A-D/Portals 2-000A AV Systems Modernization Project
Solicitation number
95476724R0206
Issued by

About this file

This document is a Request for Proposals (RFP) for the USHMM Classrooms A-D/Portals 2-000A AV Systems Modernization Project. The United States Holocaust Memorial Museum is seeking an experienced engineering/integration company to implement a modernized audio-visual infrastructure design in five classroom/multipurpose spaces. The work involves installation of hardware, cabling, software configuration, and control system programming. Interested offerors must have demonstrated expertise in similar systems. A mandatory site visit is scheduled for June 17, 2024, and proposals are due by July 10, 2024. The solicitation number is 95476724R0206 and the point of contact is Mary Green, Contract Specialist. The museum will provide the selected contractor with a detailed set of design documents to build the systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P lo t D at e

ISSUE DATE:

100 RAOUL WALLENBERG PLACE, SW.

WASHINGTON, DC 20024-2126

202.488.0400 ushmm.org

VOLUME I OF I

ISSUED FOR:

100%/PERMIT SET

1700 NEW YORK AVENUE NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 smithgroup.com

USHMM CONFERENCE ROOM UPGRADE

7/

/2

1:

:3

P

M

1201 MARYLAND AVE SW

WASHINGTON, DC 20024

02.26.2024

The United States Holocaust Memorial Museum

12241

EXHIBIT IIb

PROJECT SCOPE INCLUDES DOOR, AV AND LIGHTING UPGRADE. NO CHANGE OF USE OR OCCUPANCY.

THE FOLLOWING PROJECT GENERAL NOTES APPLY TO THE

ENTIRE DRAWING SET AND ARE NOT SPECIFIC TO ANY ONE

DISCIPLINE, UNLESS OTHERWISE NOTED:

1. THE DRAWING SET AND SPECIFICATIONS (PROJECT

MANUAL) ARE COMPLEMENTARY AND ESTABLISH

DETAILED MINIMUM REQUIREMENTS FOR THE DESIGN AND

CONSTRUCTION OF THE PROJECT.

2. THE DRAWING SET CONSISTS OF ALL SHEETS LISTED BY

THE SHEET INDEX. THE WORK DESCRIBED BY THE

DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY

THE WORK DESCRIBED ON DRAWINGS OF ANOTHER

DISCIPLINE AND MAY REQUIRE REFERENCE TO DRAWINGS

OF ANOTHER DISCIPLINE. AS SUCH, DO NOT DISTRIBUTE

OR UTILIZE PARTIAL SETS OF DRAWINGS.

3. COLUMN GRID LINES IDENTIFIED BY A LETTER

DESIGNATION ARE PARALLEL, UNLESS OTHERWISE

NOTED. COLUMN GRID LINES IDENTIFIED BY A NUMBER

DESIGNATION ARE PARALLEL AND ARE PERPENDICULAR

TO THOSE WITH LETTER DESIGNATIONS, UNLESS

OTHERWISE NOTED.

4. DISCIPLINE GENERAL NOTES, SYMBOLS AND DEFINITIONS

APPLICABLE TO EACH DISCIPLINE'S DRAWINGS MAY BE

FOUND AT THE FRONT OF EACH DISCIPLINE'S PORTION OF

THE DRAWING SET AND ARE LISTED IN THE SHEET INDEX.

5. UNLESS INDICATED OTHERWISE, THE 'ARCHITECTURAL'

SERIES DRAWINGS TAKE PRECEDENCE FOR THE FINISHED

APPEARANCE AND LOCATION OF ALL EXPOSED ELEMENTS

OF THE WORK OF ALL TRADES, INCLUDING THAT WORK

WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF

OTHER DISCIPLINES.

6. THE DRAWINGS MAY MAKE REFERENCE TO OR

ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK

OF THE CONTRACT. THESE "NOT IN CONTRACT" ITEMS AS

INDICATED ARE REFERENCED OR ILLUSTRATED FOR THE

CONTRACTOR'S REFERENCE, INFORMATION AND

COORDINATION ONLY.

7. EXISTING CONDITIONS, IF SHOWN, ARE FROM AVAILABLE

RECORD DRAWINGS AND/OR VISUAL FIELD SURVEYS.

VERIFY ACTUAL EXISTING CONDITIONS AT THE SITE PRIOR

TO SUBMITTING A BID. NOTIFY THE ARCHITECT, IN

WRITING AND PRIOR TO SUBMITTING A BID, OF ANY

DISCREPANCIES.

8. TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW

WORK AS WELL AS EXISTING SYSTEMS AND ELEMENTS, IF

ANY, WHICH ARE TO REMAIN OR BE SALVAGED. ANY

DAMAGE TO SUCH SYSTEMS AND ELEMENTS SHALL BE

IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO

THE ARCHITECT. IF SATISFACTORY REPAIRS CANNOT BE

MADE, REPLACE SYSTEMS AND ELEMENTS WITH "LIKE

NEW" QUALITY ACCEPTABLE TO THE ARCHITECT, ALL AT

NO ADDITIONAL COST.

9. ALL PARTS OF THE WORK, INCLUDING BUT NOT

LIMITED TO MATERIALS, METHODS, OR ASSEMBLIES,

MUST COMPLY WITH THE REQUIREMENTS OF THE

GOVERNING CODES AND REGULATIONS OF ALL

FEDERAL, STATE AND LOCAL AUTHORITIES HAVING

JURISDICTION OVER THE PROJECT, AS WELL AS

THOSE GREATER REQUIREMENTS INDICATED BY THE

CONTRACT DOCUMENTS. NO PART OF THE CONTRACT

DOCUMENTS MAY BE CONSTRUED TO REQUIRE OR

ALLOW WORK CONTRARY TO A GOVERNING CODE OR

REGULATION.

10. IDENTIFY AND NOTIFY THE ARCHITECT OF CONFLICTS

BETWEEN THE WORK OF DIFFERENT PARTIES AT THE

EARLIEST POSSIBLE DATE SO AS TO ALLOW

REASONABLE AND ADEQUATE TIME FOR THE

CONFLICT TO BE RESOLVED WITHOUT DELAYING THE

WORK. ALL DEVIATIONS FROM THE CONTRACT

DOCUMENTS MUST BE APPROVED IN ADVANCE BY THE

ARCHITECT AND OWNER.

11. REVIEW AND COORDINATE THE WORK OF ALL OTHER

PARTIES PERFORMING WORK AT THE PROJECT,

INCLUDING BUT NOT LIMITED TO, DELEGATED DESIGN

ENTITIES, TRADES AND SUPPLIERS WITH THE

REQUIREMENTS OF THE CONTRACT DOCUMENTS

BEFORE COMMENCING CONSTRUCTION, AND ASSURE

THAT ALL PARTIES ARE AWARE OF ALL

REQUIREMENTS, REGARDLESS OF WHERE THE

REQUIREMENTS OCCUR IN THE CONTRACT

DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF

THAT PARTY.

B

SHEET NUMBER

PROJECT NUMBER

SHEET TITLE

SEALS AND SIGNATURES

ISSUED FOR REV DATE

1700 NEW YORK AVENUE NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 smithgroup.com

P lo t D at e

USHMM CONFERENCE

ROOM UPGRADE

1201 Maryland Ave SW Washington, DC 20024

7/

/2

1:

:3

P

M

PROJECT SHEET INDEX

AND GENERAL PROJECT

INFORMATION - PORTALS

G102

S T

A R

T S he e t

12241

PROJECT GENERAL

NOTES

VICINITY MAP

OWNER / CLIENT:

UNITED STATES HOLOCAUST MEMORIAL MUSEUM

100 RAOUL WALLENBERG PI SW

WASHINGTON / DC / 20024

T: 202.488.0400

WEBSITE: USHMM.ORG

ARCHITECT:

SMITHGROUP

1700 NEW YORK AVENUE NW

SUITE 100

WASHINGTON / DC / 20006

T: 202.842.2100 WEBSITE: smithgroup.com

MECHANICAL ENGINEER:

SMITHGROUP

1700 NEW YORK AVENUE NW

SUITE 100

WASHINGTON / DC / 20006

T: 202.842.2100 WEBSITE: smithgroup.com

ELECTRICAL ENGINEER:

SMITHGROUP

1700 NEW YORK AVENUE NW

SUITE 100

WASHINGTON / DC / 20006

T: 202.842.2100 WEBSITE: smithgroup.com

AV/ IT/ ACOUSTICS:

ARUP USA, Inc

1120 CONNECTICUT AVENUE NW

SUITE 1110

WASHINGTON / DC / 20036

T: 202.729.8220 WEBSITE: www.arup.com

PROJECT TEAM

PROJECT DESCRIPTION

PROJECT SHEET INDEX

100% / PERMIT SET 07.21.2023

AV-701 AUDIOVISUAL GENERAL DETAILS SHEET 2

AV-700 AUDIOVISUAL GENERAL DETAILS SHEET 1

AV-602 AUDIOVISUAL PORTALS FUNCTIONAL

AV-500 AUDIOVISUAL PLATE DETAILS

AV-302 AUDIOVISUAL ENLARGED PORTALS RCP

AV-202 AUDIOVISUAL ENLARGED PORTALS PLAN

AV-101 AUDIOVISUAL OVERALL PORTALS PLAN

AV-000 AUDIOVISUAL GENERAL NOTES, SYMBOLS, & ABBREVIATIONS

AV

E603 ELECTRICAL DETAILS - PORTALS

E602 ELECTRICAL DETAILS - PORTALS

E501 ELECTRICAL DIAGRAMS, LIGHTING FIXTURE & PANEL SCHEDULE

E202 FLOOR PLAN OVERALL- PORTAL

E002 ELECTRICAL SCHEDULES - PORTAL

E001 ELECTRICAL ABBREVIATIONS AND SYMBOLS - PORTALS

ELECTRICAL

A723 ENLARGED FLOOR PLAN & REFLECTED CEILING PLAN - PORTALS

A212 LEVEL 02 FLOOR PLAN - PORTALS

A004 TYPICAL REFLECTED CEILING PLAN LOCATIONS AND CONFIGURATIONS

A003 TYPICAL RULES FOR DETERMINING MOUNTING HEIGHTS AND LOCATIONS

A002 TYPICAL MOUNTING HEIGHTS AND DIMENSIONING CONVENTIONS

A001 ARCHITECTURAL ABBREVIATIONS AND SYMBOLS

ARCHITECTURAL

G212 PROJECT SHEET INDEX AND GENERAL PROJECT INFORMATION - PORTALS

G102 PROJECT SHEET INDEX AND GENERAL PROJECT INFORMATION - PORTALS

G000 PROJECT COVER SHEET - PORTALS

GENERAL

A. THE PURPOSE OF THE FIRE AND LIFE SAFETY DRAWINGS IS TO

ILLUSTRATE IN SCHEMATIC FASHION, THE APPLICABLE

EXITING, FIRE-RESISTANCE, AND LIFE SAFETY CONCEPTS

UTILIZED BY THIS PROJECT; INCLUDING, BUT NOT LIMITED TO:

• OCCUPANCY CLASSIFICATIONS

• OCCUPANCY LOAD FACTORS

• EXIT LOCATIONS, EXIT PATHS & CAPACITY - FUNCTION OF

SPACE

• FIRE-RESISTANCE RATED CONSTRUCTION

• AND OTHER STRATEGIES RELATED TO THE CODE

COMPLIANCE APPROACH OF THIS PROJECT.

B. ADDITIONAL DETAILED REQUIREMENTS APPLY TO THE

CONSTRUCTION OF PARTITIONS, FIRE RATED DOOR

ASSEMBLIES, INTERIOR GLAZED OPENINGS, DUCTS, SMOKE

AND FIRE DAMPERS AND THROUGH PENETRATION FIRE

STOPPING. REFER TO THE DRAWINGS OF EACH DISCIPLINE

AND THE SPECIFICATIONS FOR THESE REQUIREMENTS.

C. ADDITIONAL DETAILED REQUIREMENTS SHOWN ELSEWHERE

MAY REQUIRE CONSTRUCTION HAVING GREATER FIRE

RATINGS, MORE EXTENSIVE FIRE-RATED CONSTRUCTION,OR

MORE COMPLEX ASSEMBLIES THAN INDICATED BY THE

DIAGRAMS ON THIS SHEET. WHEN PROVIDED, THE ADDITIONAL

DETAILED REQUIREMENTS SHALL GOVERN.

E. FIRE BARRIERS SHALL EXTEND FROM THE TOP OF THE

FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO THE

UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR

DECK ABOVE AND SHALL BE SECURELY ATTACHED THERETO.

SUCH FIRE BARRIERS SHALL BE CONTINUOUS THROUGH

CONCEALED SPACES.

F. SHAFT ENCLOSURES SHALL BE CONSTRUCTED AS FIRE

BARRIERS.

G. FIRE PARTITIONS SHALL EXTEND FROM THE TOP OF THE

FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO THE

UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR

DECK ABOVE OR TO THE FIRE-RESISTANCE-RATED

FLOOR/CEILING OR ROOF/CEILING ASSEMBLY ABOVE, AND

SHALL BE SECURELY ATTACHED THERETO.

H. SMOKE BARRIERS SHALL FORM AN EFFECTIVE MEMBRANE

CONTINUOUS FROM OUTSIDE WALL TO OUTSIDE WALL AND

FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING

ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR

ROOF SHEATHING, DECK OR SLAB ABOVE, INCLUDING

CONTINUITY THROUGH CONCEALED SPACES.

J. SMOKE PARTITIONS SHALL EXTEND FROM THE TOP OF THE

FOUNDATION OR FLOOR BELOW TO THE UNDERSIDE OF THE

FLOOR OR ROOF SHEATHING, DECK OR SLAB ABOVE OR TO

THE UNDERSIDE OF THE CEILING ABOVE WHERE THE CEILING

MEMBRANE IS CONSTRUCTED TO LIMIT THE TRANSFER OF

SMOKE.

A. A SIGN COMPLYING WITH IBC SECTION 1111 SHALL BE

PROVIDED AT EACH LANDING OF THE ELEVATOR AND SAY THE

FOLLOWING: "IN FIRE EMERGENCY, DO NOT USE THE

ELEVATOR. USE EXIT STAIRS".

B. INTERIOR WALL & CEILING FINISHES SHALL HAVE A FLAME

SPREAD INDEX RATING OF NO MORE THAN CLASS B AT

VERTICAL EXITS & EXIT PASSAGEWAYS AND EXIT ACCESS

CORRIDORS AND OTHER EXITWAYS.

C. INTERIOR WALL & CEILING FINISHES SHALL HAVE A FLAME

SPREAD INDEX RATING OF NO MORE THAN CLASS C AT

ROOMS AND ENCLOSED SPACES.

D. ALL MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL

HAVE A FLAME SPREAD RATING INDEX NOT MORE THAN 25

AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 50.

E. FIRE EXTINGUISHERS SHALL BE LOCATED SUCH THAT A

MAXIMUM TRAVEL DISTANCE OF 75' SHALL NOT BE EXCEEDED

(WHERE REQUIRED BY CODE).

F. LEVEL/ AREA MAIN OCCUPANCY EXIT SIGN LOCATIONS MAY

NOT BE SHOWN. REFERENCE ELECTRICAL SHEETS FOR ALL

EXIT SIGN LOCATIONS.

G. FIRE RESISTIVE ASSEMBLY DETAILS, IF APPLICABLE, ARE

LOCATED ELSEWHERE IN THIS DRAWING SET PER THE SHEET

INDEX.

H. ELEVATOR HOISTWAY OPENINGS SHALL BE PROTECTED AS

REQUIRED BY THE CODE, CORRESPONDING TO THE RATING

OF THE HOISTWAY.

J. EVERY ASSEMBLY OCCUPANCY ROOM OR SPACE SHALL HAVE

THE OCCUPANT LOAD POSTED IN A CONSPICUOUS PLACE.

SHEET NUMBER

PROJECT NUMBER

SHEET TITLE

SEALS AND SIGNATURES

ISSUED FOR REV DATE

1700 NEW YORK AVENUE NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 smithgroup.com

P lo t D at e

USHMM CONFERENCE

ROOM UPGRADE

1201 Maryland Ave SW Washington, DC 20024

7/

/2

1:

:3

P

M

BUILDING CODE

SUMMARY - PORTALS

G212

A ut ho r

12241

GENERAL FIRE AND LIFE

SAFETY SHEET NOTES

DEFERRED SUBMITTALS

PROJECT FIRE AND LIFE

SAFETY SHEET NOTES

CODES / STANDARDSPROJECT CODE SUMMARY CODE COMPLIANCE

APPROACH NARRATIVE

CODE COMPLIANCE APPROACH:

NO ALTERATION TO SPACE TYPE THEREFORE NO ADDITIONAL CODE

REVIEW REQUIRED.

APPLICABLE CODES/CRITERIA/DESIGN POLICY:

AUTHORITY HAVING JURISDICTION:

DISTRICT OF COLUMBIA DEPARTMENT OF BUILDINGS (DOB)

LIFE SAFETY SYSTEMS:

AUTOMATIC SPRINKLER SYSTEM : PROVIDED PER NFPA 13

ALTERNATIVE AUTOMATIC FIRE-

EXTINGUISHING SYSTEMS :

PROVIDED - REFER TO FIRE

PROTECTION DRAWINGS

STANDPIPE SYSTEM : PROVIDED PER NFPA 14: CLASS I

PORTABLE FIRE EXTINGUISHERS : PROVIDED PER NFPA 10

FIRE ALARM SYSTEM : PROVIDED PER NFPA 72

(PER IBC AND IFC CHAPTER 9)

0 < 3 FT

3 < 5 FT

5 < 10 FT

10 < 15 FT

15 < 20 FT

20 < 25 FT

25 < 30 FT

30 FT >

MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE

SEPARATION DISTANCE:

FIRE SEPARATION

DISTANCE (UP, NS) (UP, S) (P)

NP

NP

10% 15% 25% 45% 70%

NL

DEGREE OF PROTECTION

NP

15% 25% 45% 75%

NL

NL

NR

NP

15% 25% 45% 75%

NL

NL

NR

[PER IBC TABLE 705.8]

X < 5 FT

5 FT < X < 10 FT

10 FT < X < 30 FT

X > 30 FT

FIRE-RESISTANCE RATING FOR EXTERIOR WALLS BASED ON FIRE

SEPARATION DISTANCE {X} :

CONSTRUCTION

TYPE / OCCUPANCY IIB / B

1 HOURS

1 HOURS

0 HOURS

0 HOURS

2 HOURS

1 HOURS

2 HOURS

0 HOURS

1 HOURS

1 HOURS

1 HOURS

0 HOURS

1 HOURS

1 HOURS

1 HOURS

0 HOURS

IA / S-1 IIIA / A-3 VA / R-1

[PER IBC TABLE 602]

TYPE OF CONSTRUCTION:

PRIMARY STRUCTURAL FRAME :

BEARING WALLS (EXT) :

BEARING WALLS (INTR) :

NON-BRG WALLS AND PARTITIONS (EXT)

NON-BRG WALLS AND PARTITIONS (INTR) :

FLOOR CONSTR AND SECONDARY MEMBERS :

ROOF CONSTR AND SECONDARY MEMBERS :

IA

3 HOURS

3 HOURS

3 HOURS

0 HOURS

0 HOURS

2 HOURS

1.5 HOURS

IIB

0 HOURS

0 HOURS

0 HOURS

0 HOURS

0 HOURS

0 HOURS

0 HOURS

PER IBC TABLE 601:

MINIMUM FIRE-RESISTANCE REQUIREMENTS:

FIRE-RESISTIVE RATING REQUIREMENTS FOR BUILDING ELEMENTS :

[PER IBC TABLE 601]

BUILDING AREA CALCULATIONS:

UNLIMITED AREA ALLOWED

UNLIMITED HEIGHT ALLOWED

UNLIMITED AREA BUILDING

NONSPRINKLERED, ONE-STORY, 60 FOOT YARDS

SPRINKLERED, ONE-STORY ABOVE GRADE PLANE, 60' YARDS

SPRINKLERED, TWO STORIES ABOVE GRADE PLANE, 60' YARDS

AUTOMATIC SPRINKLER SYSTEM INCREASE USED FOR ALLOWABLE

HEIGHT MODIFICATION

20 FEET AND ONE STORY

NO ALLOWABLE HEIGHT OR AREA MODIFICATIONS USED

ALLOWABLE AREA MODIFICATIONS USED PER THE ALLOWABLE AREA

CALCULATIONS ON THIS SHEET:

BUILDING AREA MODIFICATIONS

FRONTAGE INCREASE

(PER IBC EQUATION 5-1)

(PER IBC 504.1)

(PER IBC TABLE 506.2)

(PER IBC EQUATION 5-2)

(PER IBC SECTION 507)

PER IBC CHAPTER 5

(PER IBC TABLE 504.3)

PROJECT CODE SUMMARY SYMBOLS

ITEM NOT SELECTED

ITEM SELECTED

BASIC OCCUPANCY GROUP(S) :

BUILDING CLASSIFICATION:

ACCESSORY OCCUPANCIES

[Accessory Occupancies <10% of Story]

INCIDENTAL USES

NONSEPARATED OCCUPANCIES*

SEPARATED OCCUPANCIES

*REFER TO FIRE AND LIFE SAFETY PLANS FOR SEPARATION

REQUIREMENTS

GROUP A-1 GROUP A-2 GROUP A-3

GROUP A-4 GROUP A-5 GROUP B

GROUP E GROUP F-1 GROUP F-2

GROUP H-1 GROUP H-2 GROUP H-3

GROUP H-4 GROUP H-5 GROUP I-1

GROUP I-2 GROUP I-3 GROUP I-4

GROUP M GROUP R-1 GROUP R-2

GROUP R-3 GROUP R-4 GROUP S-1

GROUP S-2 GROUP U

TYPE I : A B

TYPE II : A B

TYPE III : A B

TYPE IV : HT

TYPE V : A B

MIXED USE AND OCCUPANCY :

SPECIAL DETAILED REQUIREMENTS :

HIGH-RISE BUILDING

ATRIUM

OPEN PARKING GARAGE

GROUP I-2:

- SMOKE COMPARTMENTS

- REFUGE AREA

HAZARDOUS MATERIALS:

- CONTROL AREAS

MEZZANINE

EQUIPMENT PLATFORM

TYPE(S) OF CONSTRUCTION :

[PER IBC CHAPTER 3]

[PER IBC SECTION 508 & 509]

OCCUPANCY CLASSIFICATION AND CONSTRUCTION TYPES PER IBC

CHAPTERS 3, 4, 5, AND 6

[IBC 508.2]

[IBC 508.3]

[IBC 508.4]

[PER IBC CHAPTER 6]

[PER IBC SECTION 403]

[PER IBC SECTION 404]

[PER IBC SECTION 505]

[IBC SECTION 509]

[PER IBC SECTION 406.5]

[PER IBC SECTION 407]

[PER IBC SECTION 414]

[PER IBC SECTION 505]

SHAFT ENCLOSURES

FOUR STORIES OR MORE :

LESS THAN FOUR STORIES:

EXIT ENCLOSURES

FOUR STORIES OR MORE :

LESS THAN FOUR STORIES:

EXIT PASSAGEWAYS :

HOISTWAY ENCLOSURES :

ELEVATOR MACHINE ROOMS :

ADDITIONAL FIRE-RESISTIVE RATINGS :

DESCRIPTION CODE SECTION RATING (HR)

CORRIDORS:

OCCUPANCY: OCC LOAD SERVED: RATING (HR):

OCCUPANCY: OCC LOAD SERVED: RATING (HR):

SPRINKLERED:

NOTE: ALL SHAFT ENCLOSURES THAT PENETRATE FLOORS

RATED FOR 2 OR MORE HOURS SHALL BE 2-HOUR RATED SHAFTS

IBC 713

IBC 1023.2

IBC 1024.3

IBC 3002.1

IBC 3005.4

B >30 1

A All 1

[IBC TABLE 1020.1]

FIRE DOOR AND FIRE SHUTTER FIRE PROTECTION RATINGS (hours):

TYPE OF

ASSEMBLY

REQ'D

ASSEMBLY

RATING

MIN. FIRE DOOR

AND FIRE SHUTTER

ASSEMBLY RATING

Fire walls and fire barriers having a required fire-resistance rating greater than 1 hour

Fire barriers having a required fire-resistance rating of 1 hour

Fire partitions

Exterior Walls

Smoke Barriers

Shaft, exit enclosure and exit passageway walls:

Other fire barriers:

1 1/2

0.5

0.5

Corridor walls:

Other fire partitions:

1 1/2 1 1/2

3/4

1/3 1/3 3/4 1/3

1 1/2 1 1/2 3/4

1/3

[PER IBC TABLE 716.5]

MEANS OF EGRESS:

DOORS :

THE MINIMUM CLEAR WIDTH AND HEIGHT OF A DOOR SHALL NOT

BE LESS THAN 32 INCHES AND 80 INCHES RESPECTIVELY.

DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL,

WHERE SERVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS

OR A GROUP H OCCUPANCY.

*REFER TO THE LIFE SAFETY PLANS FOR ACTUAL MEASURED

DISTANCES.

[PER IBC 1008.1.1]

[PER IBC 1008.1.2]

EXIT CAPACITY FACTORS:

MINIMUM REQUIRED EGRESS WIDTH :

STAIRWAYS

OTHER EGRESS COMPONENTS

SPRINKLERED

EMERGENCY

VOICE/ALARM

COMMUNICATION

SYSTEM

*REFER TO THE LIFE SAFETY PLANS FOR COMPLIANCE WITH MEANS

OF EGRESS WIDTH REQUIREMENTS.

[PER IBC 1005.1]

0.3 0.2

BUILDING OCCUPANCY SUMMARY

GRAPHIC LEGEND

NO PROPOSED CHANGES TO OCCUPANCY; ONLY FINISH AND ELECTRICAL UPGRADES ARE REQUIRED.

ANTICIPATED DEFERRED SUBMITTALS

A. FIRE PROTECTION DESIGN

B. FIRE ALARM DESIGN

C. BUILDING SIGNAGE (NON CODE REQUIRED)

D. SECURITY SYSTEM DESIGN

E. CCTV, PA SYSTEM

F. FURNITURE SYSTEMS

G. PRE-MANUFACTURED STAIRS

H. EXTERIOR CURTAIN WALL SYSTEM

J. ----

INTERNATIONAL BUILDING CODES

(IBC) INTERNATIONAL BUILDING CODE 2015

(IEBC) INTERNATIONAL REHABILITATION CODE 2015

(IECC) INTERNATIONAL ENERGY CONSERVATION CODE 2015

(IFC) INTERNATIONAL FIRE CODE 2015

(IMC) INTERNATIONAL MECHANICAL CODE 2015

(IPC) INTERNATIONAL PLUMBING CODE 2015

NATIONAL FIRE PROTECTION ASSOCIATION

NFPA 10 STANDARD FOR PORTABLE FIRE

EXTINGUISHERS

NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS 2013

NFPA 14 STANDARD FOR THE INSTALLATION OF

STANDPIPE AND HOSE SYSTEMS

NFPA 70 NATIONAL ELECTRICAL CODE 2014

NFPA 72 NATIONAL FIRE ALARM AND SIGNALING

CODE

NFPA 101 LIFE SAFETY CODE 2015

ACCESSIBILITY GUIDELINES

ADA ADA STANDARDS FOR ACCESSIBLE DESIGN

BY THE U.S. DEPARTMENT OF JUSTICE

ICC/ANSI

117.1

ACCESSIBLE AND USABLE BUILDINGS AND

FACILITIES

ADDITIONAL GUIDELINES

ASME

A17.1

SAFETY CODE FOR ELEVATORS AND

ESCALATORS

COMMON PATH OF EGRESS TRAVEL (IBC 1006.2.1)

OCCUPANCY SPRINKLERED MAX. DISTANCE

B YES 100' - 0"

R-2 YES 125' - 0"

EXIT ACCESS TRAVEL DISTANCE (IBC TABLE 1017.2)

OCCUPANCY SPRINKLERED MAX. DISTANCE

B YES 250' - 0"

DEAD ENDS (IBC 1020.4)

OCCUPANCY SPRINKLERED MAX. DISTANCE

B YES 50' - 0"

MIN. NUMBER OF EXITS FOR OCCUPANT LOAD (IBC TABLE 1006.3.2)

OCCUPANT LOAD MIN. # OF EXITS PER STORY

1-500 2

501-1,000 3

MORE THAN 1,000 4

100% / PERMIT SET 07.21.2023

AB

A

ANCHOR BOLT

ACT ACOUSTICAL CEILING TILE

ACP

AD

ACOUSTICAL CEILING PANEL

AREA DRAIN

ADDL ADDITIONAL

ADH

ADDITIONAL

ADJ

ADHESIVE

ADJ

ADJUSTABLE

AFF

ADJACENT

AFG

ABOVE FINISH FLOOR

AFS

ABOVE FINISH GRADE

AGGR

ABOVE FINISH SLAB

ALUM

AGGREGATE

ALT

ALUMINUM

ANOD

ALTERNATE

APPROX

ANODIZED

ARCH

APPROXIMATE(LY)

ACS PNL ACCESS PANEL

ARCHITECT(URAL)

ASPH ASPHALT

AVG AVERAGE

BB

B

BULLETIN BOARD

BD BOARD

BTWN

BLDG

BETWEEN

BUILDING

BM

BOT

BENCHMARK

BOTTOM

BITUM BITUMINOUS

BOS BOTTOM OF STEEL

BRG BEARING

BSMT BASEMENT

CAB

C

CABINET

CB CATCH BASIN

CCT

CG

CUBICLE CURTAIN TRACK

CORNER GUARD

CEM

CER

CEMENT, CEMENTITIOUS

CERAMIC

CCTV CLOSED CIRCUIT TELEVISION

CH BD CHALKBOARD

CI CAST IRON

CJ CONTROL JOINT

CL

CLG

CLR

CMU

CNTR

COL

CONC

CONF

CONN

CONSTR

CONT

CONTR

CORR

CPT

CSK

CSP

CSWK

CU

CW

CENTER LINE

CEILING

CLEAR

CONCRETE MASONRY UNIT

COUNTER

COLUMN

CONCRETE

CONFERENCE

CONNECTION

CONSTRUCTION

CONTINUOUS

CONTRACTOR

CORRUGATED

CARPET

COUNTERSUNK

COMBINATION STANDPIPE

CASEWORK

CUBIC

COLD WATER

D

D

DEPTH

DBL DOUBLE

DBL ACT DOUBLE ACTING

DEG DEGREE

DEMO DEMOLISH

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIFF DIFFUSER

DIM DIMENSION

DIM PT DIMENSION POINT

DISP DISPENSER

DIST DISTANCE

DN DOWN

DR DRAIN

DS DOWNSPOUT

DSP DRY STANDPIPE

DT DRAPERY TRACK

DWG DRAWING

DWGS DRAWINGS

(E)

E

EXISTING

EA EACH

EDR EQUIPMENT DRAWING

EG EDGE GUARD

EIFS EXTERIOR INSULATION FINISH SYSTEM

EL ELEVATION

ELAST ELASTOMERIC

ELEC ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

ENCL ENCLOSURE

ENGR ENGINEER

EOS EDGE OF SLAB

EP ELECTRICAL PANEL

EPB ELECTRICAL PANEL BOARD

EPDM ETHYLENE PROPYLENE DIENE MONOMER

EQ EQUAL

EQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EQUIV EQUIVALENT

ESCAL ESCALATOR

EST ESTIMATE(D)

EWC ELECTRIC WATER COOLER

EXC EXCAVATED

EXH EXHAUST

EXP EXPANSION

EXP JT EXPANSION JOINT

EXT EXTERIOR

F/F

F

FACE TO FACE

FA FIRE ALARM

FAS FIRE ALARM STATION

FB FLAT BAR

FCU FAN COIL UNIT

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDN FOUNDATION

FEC FIRE EXTINGUISHER CABINET

FE FIRE EXTINGUISHER

FF FINISH FACE

FHC FIRE HOSE CABINET

FH/FEC FIRE HOSE / FIRE EXTINGUISHER CABINET

FHMS FLAT HEAD MACHINE SCREW

FHWS FLAT HEAD WOOD SCREW

FHY FIRE HYDRANT

FLAM FLAMMABLE

FLASH FLASHING

FLEX FLEXIBLE

FLUOR FLUORESCENT

FO FACE OF

FSB FOLDING SHOWER BENCH

FSTNR FASTENER

FT FOOT, FEET

FTG FOOTING

FURN FURNITURE

FXTR FIXTURE

G

G

GAS

H

H

HIGH

GA GAUGE, GAGE

GAL GALLON

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GFRC GLASS FIBER REINFORCED CONCRETE

GFRG GLASS FIBER REINFORCED GYPSUM

GL GLASS

GLU LAM GLUE LAMINATED

GLZ GLAZING

GR GRADE OR GRADING

GVL GRAVEL

GYP GYPSUM

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

ID

I

INSIDE DIAMETER

JAN

J

JANITOR

KG

K

KILOGRAM

L

L

LENGTH, LONG

M

M

METERS

(N)

N

NEW

OC

O

ON CENTER

PA

P

PUBLIC ADDRESS

QT

Q

QUARRY TILE

R

R

RISER

S SOUTH

T

T

TREAD

VAC

V

VACUUM

W

W

WEST

XFMR

X

TRANSFORMER

YD

Y

YARD

HB HOSE BIBB

HC HOLLOW CORE

HD HEAD

HDBD HARDBOARD

HDW HARDWARE

HDWD HARDWOOD

HGT HEIGHT

HM HOLLOW METAL

HNDRL HANDRAIL

HORIZ HORIZONTAL

HPT HIGH POINT

HR HOUR

HVAC HEATING-VENTILATION-AIR CONDITIONING

IN INCH

INCAND INCANDESCENT

INCL INCLUDE, INCLUDING

INFO INFORMATION

INSUL INSULATION

INTR INTERIOR

INV INVERT

IVT INTRAVENOUS TRACK

JST JOIST

JT JOINT

KIT KITCHEN

KPL KICK PLATE

KS KNEE SPACE

LAB LABORATORY

LAM LAMINATE, LAMINATION

LAV LAVATORY

LB POUND

LED LIGHT EMITTING DIODE

LF LINEAR FOOT

LG LENGTH

LIN LINEAR

LL LEAD LINED

LPT LOW POINT

LT LIGHT

LT WT LIGHT WEIGHT

LTG LIGHTING

LVR LOUVER

HW HOT WATER S

MACH MACHINE

MATL MATERIAL

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MB MACHINE BOLT

MC MEDICINE CABINET

MDO MEDIUM DENSITY OVERLAY

MECH MECHANICAL

MED MEDIUM

MEMB MEMBRANE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MLDG MOLDING

MM MILLIMETERS

MO MASONRY OPENING

MOD MODULE, MODULAR

MTD MOUNTED

MTG MOUNTING

MVBL MOVABLE

MULL MULLION

NA NOT APPLICABLE

NAT NATURAL

NE NORTHEAST

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NRC NOICE REDUCTION COEFFICIENT

NTS NOT TO SCALE

NW NORTHWEST

OA OVERALL

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED-CONTRACTOR INSTALLED

OFOI OWNER FURNISHED-OWNER INSTALLED

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

OVHD OVERHEAD

OZ OUNCE

PART PARTIAL

PBD PARTICLEBOARD

PBX PRIVATE TELEPHONE EXCHANGE

PCF POUNDS PER CUBIC FOOT

PCI POUNDS PER CUBIC INCH

PERF PERFORATED

PERIM PERIMETER

PERM PERMANENT

PERP PERPENDICULAR

PI POINT OF INTERSECTION

PL PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLBG PLUMBING

PLF POUNDS PER LINEAR FOOT

PLYWD PLYWOOD

PNEU PNEUMATIC

PNL PANEL

PNL BD PANEL BOARD

PNT PAINT

PORT PORTABLE

PP PUSH PLATE

PPM PARTS PER MILLION

PR PAIR

PRCST PRECAST

PREP PREPARATION

PREFAB PREFABRICATION

PRKG PARKING

PROJ PROJECT

PROP PROPERTY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT POINT

PTN PARTITION

PTS PNEUMATIC TUBE STATION

PVC POLYVINYL CHLORIDE

PVG PAVING

PVMT PAVEMENT

PWR POWER

QTR QUARTER

QTY QUANTITY

RA RETURN AIR

RAD RADIUS

RB RESILIENT BASE

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

RD ROOF DRAIN

RECT RECTANGULAR

REF REFERENCE

REFR REFRIGERATOR

REG REGISTER

REINF REINFORCE (D) (ING) (MENT)

REQD REQUIRED

REQT REQUIREMENT

RESIL RESILIENT

RET RETURN

REV REVISION

RF RESILIENT FLOORING

RH RIGHT HAND

RHMS ROUND HEAD MACHINE SCREW

RHWS ROUND HEAD WOOD SCREW

RM ROOM

RND ROUND

RO ROUGH OPENING

ROW RIGHT OF WAY

RWL RAIN WATER LEADER

SA SUPPLY AIR

SB SPLASH BLOCK

SC SOLID CORE

SCHED SCHEDULE

SCRN SCREEN

SD STORM DRAIN

SE SOUTHEAST

SECT SECTION

SEG SEGMENT

SEP SEPARATION OR SEPARATE

SEP JT SEPARATION JOINT

SHT SHEET, SHEETING

SHWR SHOWER

SHV SHELVES, SHELVING

SIM SIMILAR

SK SINK

SMS SHEET METAL SCREW

SP SPACE, SPACED, SPACING

SPEC SPECIFICATION

SPKLR SPRINKLER

SPKR SPEAKER

SQ SQUARE

SS SANITARY SEWER

SSK SERVICE SINK

SST STAINLESS STEEL

ST STREET

STA STATION

STAG STAGGERED

STC SOUND TRANSMISSION COEFFICIENT

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

STS SELF-TAPPING STEEL

SUSP SUSPENDED

SUSP CLG SUSPENDED CEILING

SVCE SERVICE

SW SOUTHWEST

SYMM SYMMETRICAL

SYST SYSTEM

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

TC TOP OF CONCRETE, TOP OF CURB

TD TRENCH DRAIN

TEL TELEPHONE

TEMP TEMPORARY

THERM THERMAL

THK THICK, THICKNESS

THRES THRESHOLD

THRU THROUGH

TMPD GL TEMPERED GLASS

TO TOP OF

TOR TOP OF RAILING

TOS TOP OF STEEL

TOT TOTAL

TOW TOP OF WALL

TP TOP OF PAVEMENT

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

UC

U

UNDER COUNTER

TYP TYPICAL

UL UNDERWRITERS LABORATORIES

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTABLE POWER SUPPLY

UTIL UTILITY

VB VALVE BOX

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIT VITREOUS

VP VENT PIPE

VOL VOLUME

VWC VINYL WALL COVERING

W/ WITH

W/O WITHOUT

W/W WALL TO WALL

WC WATER CLOSET OR WALL COVERING

WD WOOD

WDW WINDOW

WGL WIRE GLASS

WCHR WHEELCHAIR

WM WIRE MESH

WO WHERE OCCURS

WPT WORKING POINT

WR WATER RESISTANT

WSCT WAINSCOT

WSP WET STANDPIPE

WT WEIGHT

WTHPRF WEATHERPROOF

WTRPRF WATERPROOF

WWF WELDED WIRE FABRIC

WWM WELDED WIRE MESH

CCR CARD CONTROL READER

BUR BUILT UP ROOFING SYSTEM

CT CERAMIC TILE

BOD BASIS OF DESIGN

VIF VERIFY IN FIELD

THE FOLLOWING GENERAL NOTES APPLY TO ALL

ARCHITECTURAL SERIES SHEETS. FOR GENERAL NOTES

APPLICABLE TO ALL SHEETS REFER TO THE "PROJECT

GENERAL NOTES":

1. THE ARCHITECTURAL SERIES SHEETS ARE PART OF A

COMPLETE SET OF CONSTRUCTION DOCUMENTS

DESCRIBING THE WORK FOR THIS PROJECT. USERS OF

THESE DOCUMENTS ARE RESPONSIBLE TO REVIEW ALL

CONSTRUCTION DOCUMENTS TO UNDERSTAND AND

COORDINATE THE GRAPHIC AND ANNOTATED

INFORMATION PROVIDED IN THESE ARCHITECTURAL

SERIES SHEETS.

2. EXCEPT WHERE DIRECTED TO PLACE ITEMS OF WORK AT

THE APPROXIMATE LOCATIONS SHOWN, DO NOT SCALE

DRAWINGS FOR DIMENSIONAL INFORMATION. ALL

ELEMENTS OF THE DRAWINGS MAY NOT BE DRAWN TO

EXACT SCALE. ALL DIMENSIONS REQUIRED ARE SHOWN

OR MAY BE DERIVED FROM THOSE SHOWN ON THE FLOOR

PLANS, DETAIL PLANS, ELEVATIONS, SECTIONS, DETAILS,

SCHEDULES, AND SPECIFICATIONS.

1. THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE AND

DEFINE TYPICAL GRAPHIC SYMBOLS WHICH MAY

TYPICALLY OCCUR ON THE ARCHITECTURAL DRAWINGS.

2. ADDITIONAL SYMBOLS NOT SHOWN OR DEFINED ON THIS

SHEET MAY BE USED ON THE ARCHITECTURAL

DRAWINGS AND ARE TYPICALLY DEFINED ON OTHER

SHEETS.

3. SYMBOLS ARE NOT DRAWN TO SCALE. TO DETERMINE

THE ACTUAL SIZES OF ELEMENTS REPRESENTED BY

SYMBOLS, REFER TO THE SPECIFICATIONS AND OTHER

SHEETS, AS MAY APPLY.

1. THE TERM "REFERENCE" ELEVATION OR DIMENSIONS

REFERS TO A NOMINAL WORK POINT. THE ACTUAL

ELEVATION MAY VARY FROM THE REFERENCE POINT.

REFER TO APPLICABLE DETAIL TO DETERMINE THE

RELATIONSHIP BETWEEN THE ACTUAL ELEVATION OR

DIMENSION AND THE STATED REFERENCE POINT."

2. THE DESIGN REFERENCE ELEVATION +0'-0" SHOWN ON THE

ARCHITECTURAL DRAWINGS CORRESPONDS TO THE FINISH

FLOOR ELEVATION OF THE GROUND FLOOR. ESTABLISH

THE ACTUAL ELEVATION WITH RESPECT TO SITE-SPECIFIC

BENCHMARKS AND CONTROL POINTS AS DEFINED IN THE

CIVIL DRAWINGS.

3. "FINISH FLOOR" ELEVATIONS ARE MEASURED AT THE TOP

OF THE CONCRETE FLOOR SLAB UNLESS OTHERWISE

NOTED. APPLIED FINISHES SUCH AS RESILIENT FLOORING

OR CARPET MAY RAISE THE ACTUAL FINISH SURFACE

ABOVE THE REFERENCE ELEVATION PROVIDED FOR THE

FINISH FLOOR.

4. WHERE CONCRETE FLOOR SLAB IS DEPRESSED TO

ACCOMMODATE MORTAR BEDS, SETTING BEDS, RAISED

ACCESS FLOORS, AND OTHER SIMILAR FLOOR

ASSEMBLIES, "FINISHED FLOOR" ELEVATIONS ARE

MEASURED AS IF CONCRETE DEPRESSION DOES NOT

OCCUR.

5. CEILING HEIGHT ELEVATIONS ARE MEASURED TO BOTTOM

OF FINISH SURFACES AND STATED IN RELATION TO

DISTANCE ABOVE THE REFERENCE ELEVATION FOR THE

FINISH FLOOR UNLESS OTHERWISE NOTED.

6. ROOF ELEVATIONS ARE MEASURED TO TOP OF SURFACES

AND STATED IN RELATION TO DISTANCE ABOVE THE

REFERENCE ELEVATION PROVIDED FOR THE UPPERMOST

FINISH FLOOR UNLESS OTHERWISE NOTED. ELEVATIONS

GIVEN ARE TO TOP OF STEEL (TOS), TOP OF DECK (TOD),

OR TOP OF TAPERED INSULATION (TOT) UNLESS

OTHERWISE NOTED.

SECOND LEVEL

+10'-0"

BUILDING SECTION

WALL SECTION NUMBER

DIRECTION OF VIEW

SHEET WHERE DRAWN

WALL SECTION

WALL SECTION NUMBER

NORTH ARROW REFERENCES

TRUE NORTH

.00

0°

NEW GRID

IDENTIFICATION

EXISTING GRID

IDENTIFICATION

LAYOUT GRID LINES

BASIC DRAWING TITLE

SHEET WHERE DRAWN

DIRECTION OF VIEW

LEVEL LINE

REVISION NUMBER AND EXTENT

DETAIL REFERENCE

SECTION DETAIL REFERENCE

EXTERIOR ELEVATION

A102 2

INTERIOR ELEVATION REFERENCE

ROOM NAME AND NUMBER

ELEVATION NUMBER AND

DIRECTION

SHEET WHERE DRAWN

SHEET WHERE DRAWN

ELEVATION NUMBER AND

DIRECTION OF VIEW

SHEET WHERE DRAWN,

HYPHEN INDICATES DETAIL

ON SAME SHEET.

DETAIL NUMBER

SHEET WHERE DRAWN

ELEVATION NUMBER AND

DIRECTION

AX.X.X X

WINDOW AND LOUVER TYPE MARK

SEE CORRESPONDING

NUMBER ON SCHEDULE

SEE ASSEMBLY TYPE

FOR DETAILS.

NAME OF LEVEL

INDICATES HEIGHT

ABOVE PROJECT DATUM

REVISION NUMBER - SEE

REVISION HISTORY ON

THE TITLE BLOCK OF

EACH SHEET

EXTENT OF CURRENT

REVISION

SHEET KEYNOTE MARK

MATCH LINE REFERENCES

DRAWING TITLE SYMBOLS

A502

SEE CORRESPONDING

NUMBERED KEYNOTE ON

SHEET WHERE

REFERENCE OCCURS

REFER TO THE SHEET

WHERE CONTINUATION IS

FOUND

A B

SCALE:

A101

SIM

A101

SIM

A101

SIM

A101

SIM

MATCH LINE

W-X

View Name

1/8" = 1'-0"

REFERENCE KEYNOTE MARK

088000.A03

THE FIRST SIX DIGITS

REPRESENT THE

SPECIFICATION SECTION

EXAMPLE 1:

THE CHARACTERS

FOLLOWING THE PERIOD

REPRESENT PARTICULAR

ITEMS OF THE SPECIFIED

SYSTEM

NORTH PROJECT NORTH

OR OR

BASIC DRAWING TITLE

WITH LINESCALE:

View Name

1/8" = 1'-0"

DRAWING TITLE WHEN

ONLY ONE PLAN EXISTS

ON THE DRAWING

SCALE:

View Name 1/8" = 1'-0"

SHEET A2.1.1

SHEET A2.1.2

SHEET A2.1.1

OR

REFER TO THE SHEETS

EITHER SIDE OF THE

MATCH LINE

Room Name

M-X

061600 5/8"

PLYWOOD

EXAMPLE 2:

THE TEXT IS THE PRODUCT

DESCRIPTION

EARTH

AGGREGATE BASE COURSE

CONCRETE

CONCRETE MASONRY UNIT

BRICK MASONRY

PRECAST CONCRETE

LIMESTONE, SANDSTONE, GRANITE

MARBLE

STEEL, STAINLESS

STEEL

(LARGE SCALE)

ALUMINUM (LARGE SCALE)

OTHER METALS (LARGE

SCALE)

WOOD FRAMING -

CONTINUOUS (LARGE SCALE)

WOOD FRAMING - DISCONTINUOUS

(LARGE SCALE)

PLYWOOD

(LARGE SCALE)

FINISH WOOD (LARGE SCALE)

EIFS INSULATION BOARD

(LARGE SCALE)

SEMI-RIGID INSULATION

(LARGE SCALE)

BATT INSULATION

(LARGE SCALE)

MORTAR, SAND, FIREPROOFING,

STUCCO, GYPSUM BOARD

TERRAZZO (LARGE SCALE)

COMPOSITE BOARD

(LARGE SCALE)

ACOUSTIC TILE (LARGE SCALE)

PROTECTION BOARD

(LARGE SCALE)

CERAMIC TILE (LARGE SCALE)

GLASS (LARGE SCALE)

PLASTER CONCRETE

MASONRY, METAL SIDING

(HORIZONTAL)

GLASS BLOCK, CERAMIC TILE

METAL SIDING (VERTICAL)

GLASS

ELEVATION

PLAN AND SECTION

FOR THE ASSEMBLY TYPES LISTED, SEE THE FOLLOWING SHEETS FOR SYSTEM

DETAILS AND DESCRIPTIONS:

TYPE A = EXTERIOR WALLS - ABOVE GRADE - SHEET A5.0.X

TYPE B = EXTERIOR WALLS - VERTICAL BELOW GRADE - SHEET A5.0.X

TYPE H = FOUNDATION SLAB SYSTEMS - HORIZONTAL BELOW GRADE - SHEET A5.0.X

TYPE R = ROOFING SYSTEMS - SHEET A5.0.X

TYPE S = EXTERIOR SOFFITS - SHEET A5.0.X

TYPE X = EXTERIOR FENESTRATION SYSTEMS - SHEET A5.4.X

TYPE P = INTERIOR WALL PARTITIONS - SHEET A9.2.X

TYPE Y = INTERIOR FENESTRATION SYSTEMS - SHEET A9.3.X

TYPICAL ARCHITECTURAL ASSEMBLY IDENTIFICATION MARK

A000X

A000X

PLAN

SECTION

A000X

ASSEMBLY TYPE

ASSEMBLY NAME

REPRESENTING:

-MAJOR GROUP

-FINISH SYSTEM

-SUBSTRATE

CONFIGURATION

ASSEMBLY VARIABLE

(NOT ALWAYS PRESENT)

ASSEMBLY TAG DESIGNATION

EXISTING PARTITION TO

REMAIN

EXISTING PARTITION TO

BE REMOVED

EXISTING DOOR TO REMAIN

EXISTING DOOR AND

FRAME TO BE REMOVED

EXISTING WINDOW TO

REMAIN

EXISTING WINDOW TO

BE REMOVED

EXISTING LAY-IN

CEILING TO BE

REMOVED

EXISTING LAY-IN

CEILING TO

REMAIN

OVERHEAD ROLLING DOOR

PAIR DOORS - UNEQUAL SIZES

DOUBLE ACTING DOOR

SINGLE OPENING DOOR

2 PANEL BI-FOLD DOOR

PAIR - BI FOLD DOOR

DOOR OPENING MARK

PAIR DOORS - EQUAL SIZES

PAIR DOORS - DOUBLE EGRESS

DOOR WITH SIDE LIGHT

SLIDING DOOR - BETWEEN JAMBS

SLIDING POCKET DOOR

INTERIOR GLAZED WINDOW

1 HOUR FIRE RESISTANCE RATING

2 HOUR FIRE RESISTANCE RATING

3 HOUR FIRE RESISTANCE RATING

0 HOUR SMOKE PARTITION

4 HOUR FIRE RESISTANCE RATING

BASE CABINETS

BASE AND WALL CABINETS

WALL CABINETS

TOILET PARTITION AND DOOR

TOILET - WALL HUNG

URINAL - FLOOR/WALL HUNG

LAVATORY - COUNTERTOP

LAVATORY -

PEDESTAL/WALL HUNG

GENERAL SYMBOLS PLUMBING SYMBOLS

HANDRAIL

BUMPER GUARD

CG CG

CORNER GUARD

EDGE GUARD

OVERHEAD ITEMS

UNDER-COUNTER ITEMS

NIC NOT-IN-CONTRACT ITEMS

10' - 0"

10' - 0"

JANITOR'S RECEPTOR

DRINKING FOUNTAIN / EWC

EG

DIMENSION SYMBOLS

UTILITY SINK

BATHTUB

SHOWER

FLOOR DRAIN IN SLOPING

FLOOR

FEC

FEC

FEXT

FEC

FIRE EXTINGUISHER

BRACKET MOUNTED

FIRE EXTINGUISHER

SURFACE MOUNTED

FIRE EXTINGUISHER CABINET

SEMI-RECESSED

FIRE EXTINGUISHER CABINET

RECESSED

DIMENSION SHOWN TO:

- STRUCTURAL GRID

- LAYOUT GRID

- CENTERLINE OF ASSEMBLY

- CENTER OF OPENING

- CENTER OF EQUIP/ FURN

GRID OR CENTER LINE

TYPICAL

DIMENSION SHOWN TO:

- PARTITION ASSEMBLY

- EDGE OF DOOR OPENING

- OTHER BUILDING ELEMENT

- WORKING POINT INDICATED

ON DETAIL

FD

FIRE EXTINGUISHER SYMBOLS

DETAILS ARE NUMBERED ACCORDING TO THEIR

LOCATION ON EACH SHEET AND ARE NOT

NUMBERED CONSECUTIVELY. EACH MODULE

MAINTAINS THE NUMBER ASSOCIATED WITH IT

THIS SYSTEM CAN BE APPLIED TO ANY SHEET

THAT CONTAINS MULTIPLE IMAGES. THE IMAGES

ARE NUMBERED ACCORDING TO THE MODULE

SYSTEM SHOWN ILLUSTRATED TO THE LEFT

EACH DETAIL MAY OCCUPY ONE OR MORE

WHOLE MODULES. THE DETAIL MODULE IS USED

TO ESTABLISH THE IDENTIFYING LABEL FOR

EACH DETAIL, NOT TO LIMIT THE SIZE OF THE

DETAIL

DETAIL MODULE LAYOUT

DETAIL NUMBERING EXAMPLE

THE NUMBER OF THE MODULE WHICH

OCCURS IN THE LOWER LEFT CORNER OF A

SINGLE MODULE OR SEVERAL MODULES

GROUPED TOGETHER WILL DEFINE THE FINAL

DETAIL NUMBER AS SHOWN IN THE

ILLUSTRATION TO THE LEFT. ALTHOUGH THE

MODULE NUMBERS OCCUR IN CONSECUTIVE

ORDER, NOT ALL NUMBERS ARE

NECESSARILY USED ON EACH SHEET

163256

54 46

ARCHITECTURAL

2'X4' LAY IN ACOUSTIC

TILE CEILING

2'X2' LAY IN ACOUSTIC

TILE CEILING

GYPSUM BOARD

ACCESS PANELAP

MECHANICAL

SUPPLY GRILLE

RETURN GRILLE

EXHAUST GRILLE

LINEAR DIFFUSER

SPRINKLER HEAD - CLG MOUNT

SPRINKLER HEAD - WALL

MOUNT

ELECTRICAL

MISCELLANEOUS

2'X4' LIGHTING FIXTURE

2'X2' LIGHTING FIXTURE

1'X4' LIGHTING FIXTURE

LIGHTING STRIP FIXTURE

RECESSED DOWN LIGHT

WALL WASH

TRACK LIGHTING

EXIT SIGN, SINGLE-SIDED

EXIT SIGN, DOUBLE-SIDED

FIRE ALARM

SPEAKER

SMOKE DETECTOR

WIRELESS INTERNETW

P

S

F

HEIGHT OF CEILING FINISH

ABOVE FINISH FLOOR

+12'-8"

SHEET NUMBER

PROJECT NUMBER

SHEET TITLE

SEALS AND SIGNATURES

ISSUED FOR REV DATE

1700 NEW YORK AVENUE NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 smithgroup.com

P lo t D at e

USHMM CONFERENCE

ROOM UPGRADE

1201 Maryland Ave SW Washington, DC 20024

7/

/2

1:

:2

P

M

ARCHITECTURAL

ABBREVIATIONS AND

SYMBOLS

A001

S T

A R

T S he e t

12241

ARCHITECTURAL REFERENCE SYMBOLS ARCHITECTURAL GENERAL NOTESARCHITECTURAL FLOOR PLAN SYMBOLSARCHITECTURAL ABBREVIATIONS

ARCH REFLECTED CEILING PLAN SYMBOLS

DOOR AND INTERIOR OPENING SYMBOLS

ARCHITECTURAL MATERIAL INDICATIONS

MODULAR LAYOUT / DETAIL NUMBER

REFERENCE ELEVATION DEFINITIONS

FIRE RESISTIVE RATING

INDICATION

ARCHITECTURAL DEMOLITION SYMBOLS

ARCHITECTURAL SYMBOL

NOTES

ARCHITECTURAL ASSEMBLY SYSTEM TAGS

A. IT IS THE INTENT OF THE DESIGN THAT ALL ITEMS SHOWN

MOUNTED AT TYPICAL HEIGHTS BE ACCESSIBLE TO

PERSONS WITH DISABILITIES.

B. THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE TYPICAL

MOUNTING HEIGHTS AND - WHERE APPLICABLE - TYPICAL

MINIMUM OR MAXIMUM CLEARANCES AND/OR TYPICAL

MOUNTING CONFIGURATIONS FOR A VARIETY OF ITEMS.

CAUTION: THIS SHEET MAY ILLUSTRATE ITEMS OR

CONFIGURATIONS WHICH DO NOT OCCUR AS PART OF THE

WORK OF THIS PROJECT. REFER TO THE PLANS,

ELEVATIONS, SECTIONS, DETAILS, AND SCHEDULES TO

DETERMINE WHICH ITEMS AND CONFIGURATIONS APPLY TO

THE WORK OF THIS PROJECT.

C. NOT ALL PROJECT ITEMS MAY BE REPRESENTED ON THIS

SHEET. FOR ITEMS WITH OPERABLE PARTS NOT SHOWN ON

THIS SHEET, THE ITEM SHALL BE MOUNTED SUCH THAT THE

OPERABLE PART IS A MAXIMUM OF 42" ABOVE FINISH FLOOR

UNLESS SPECIFICALLY NOTED OR DIMENSIONED

OTHERWISE.

D. THE MOUNTING HEIGHTS, CLEARANCES, AND

CONFIGURATIONS SHOWN ON THIS SHEET ARE TYPICAL AND

SHALL APPLY TO ALL INSTANCES OF THE ITEM (OR GROUP

OF ITEMS) SHOWN UNLESS SPECIFICALLY NOTED OR

DIMENSIONED OTHERWISE.

E. SPECIAL OR NON-TYPICAL MOUNTING HEIGHTS OCCUR

ONLY WHERE INDICATED BY ANNOTATED SYMBOLS; BY KEY

NOTES; BY NOTES ON PLANS, ELEVATIONS, OR DETAILS; OR

BY UNIQUE DIMENSIONS ON ELEVATIONS OR DETAILS.

F. FOR ADDITIONAL INFORMATION REGARDING THE

PRECEDENCE OF DRAWINGS FOR DETERMINING THE EXACT

LOCATION OF EACH EXPOSED PART OF THE WORK, REFER

TO THE "ARCHITECTURAL GENERAL NOTES" AND TO THE

"TYPICAL RULES FOR DETERMINING MOUNTING HEIGHTS

AND LOCATIONS" LOCATED PER THE INDEX OF DRAWINGS IN

THIS SET.

G. TYPICAL MOUNTING HEIGHTS MAY BE ILLUSTRATED BY

OTHER DRAWING SERIES, SUCH AS Q SERIES. REFER TO

THE 'INDEX OF DRAWINGS' FOR ADDITIONAL INFORMATION.

H. MOUNTING CONFIGURATION DIAGRAMS ARE ELEVATIONS

WHICH ILLUSTRATE TYPICAL RULES GOVERNING THE

RELATIONSHIPS BETWEEN, AND PLACEMENT OF, ITEMS

WHICH OCCUR IN GROUPS OF RELATED ITEMS OR IN CLOSE

PROXIMITY TO OTHER PARTS OF THE WORK (SUCH AS

SWITCHES AND DOOR FRAMES). UNLESS OTHER MOUNTING

CONFIGURATIONS ARE SPECIFICALLY NOTED,

DIMENSIONED, OR ELEVATED, THE TYPICAL RELATIONSHIPS,

ARRANGEMENTS, AND THE TYPICAL CONFIGURATION

DIAGRAMS APPLY THROUGHOUT THE WORK OF THIS

PROJECT.

J. TYPICAL MOUNTING CONFIGURATIONS FOR ADDITIONAL

GROUPING NOT SHOWN ON THIS MAY BE SHOWN ON OTHER

SHEETS. REFER TO THE "INDEX OF DRAWINGS" FOR

ADDITIONAL INFORMATION.

K. A TACTILE EXIT SIGN STATING "EXIT" AND COMPLYING WITH

ICC A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR

TO AN AREA OF REFUGE, AN EXIT STAIRWAY, AN EXIT RAMP,

AN EXTERIOR AREA FOR ASSISTED RESCUE, AN EXIT

PASSAGEWAY AND THE EXIT DISCHARGE.

L. REFER TO RULE 16 ON A0.4 FOR ITEM MOUNTING HEIGHTS

IN MASONRY PARTITIONS.

T O

U N

O B

S T

R U

C T

E D

C O

N T

R O

LS

4'

M

A X

H

IG

H R

E A

C H

3'

A T

M A

S O

N R

Y W

A

LL

S 3'

T

Y P

T O

C L

C O

N T

R O

LS

R E

A C

H

1'

M

IN

LO

W

M A

S O

N R

Y W

A

LL

S

1'

T Y

P 1'

A

T

COUNTER TOP

OR BACKSPLASH

WHERE OCCURS

T O

O B

S T

R U

C T

E D

C O

N T

R O

LS

3'

M

A X

H

IG

H R

E A

C H

5" M

IN

F

O R

V E

R T

3"

M

IN

F O

R

H

R

IZ

, R E

F E

R T

IN

E R

IO

E

LE

V

A T

IO

N

S F

D

V

IC

E

H E

IG

H

T

R E

F E

R T

O E

LE

C

F

R

D E

V

IC

IE

N

T A

T

IO

N

CARD READER,

LOCAL ALARM,

OR ARMING

STATION

NURSE CALL

STATION

WITH

CONTROLS

WALL-MTD

TELEPHONE

OUTLET

SPECIAL

PURPOSE

OUTLETS

SPECIAL

PURPOSE

OUTLETS OR

JUNCTION BOX

THERMOSTATPHONE/DATA

OUTLET

INTERCOM

STATION

DESK

INTERCOM

OUTLET

DUPLEX

OUTLET

DUPLEX

OUTLET

ABOVE COUNTER OR

BACKSPLASH WHERE OCCURS

MANUAL FIRE

ALARM PULL

STATION

RACEWAYFIREMAN'S

TELEPHONE

JACK

LIGHT SWITCH

& DIMMER

CLOCK OR

CLOCK OUTLET

DARK ROOM

STATUS LIGHT

SWITCH AT

DOOR OR

CASED OPENING

7'

A F

F

A

LI

G N

W

IT

H T

O P

O F

A D

JA

C

E N

T F

R A

M E

TYP

8"

8" TYP

6" B

E

LO

W C

E

IL

IN

G

W H

IC

H

E V

E R

IS

L

O W

E R

7'

A F

F T

O C

L O

R

6" B

E

LO

W C

E

IL

IN

G

W H

IC

H

E V

E R

IS

L

O W

E R

7'

A F

F T

O C

L O

R

6" B

E

LO

W C

E

IL

IN

G

W H

IC

H

E V

E R

IS

L

O W

E R

7'

A F

F T

O C

L O

R

NURSE

CALL

STATION

WITHOUT

CONTROLS

5'

NURSE CALL

CORRIDOR

LIGHT (DOME

LIGHT)

7'

EMERGENCY

STROBE OR

LIGHT

SECURITY

STROBE LIGHT

(BLUE LIGHT)

AUDIBLE

AND/OR VISUAL

FIRE ALARM

REQD SIGNAGE

AT MEN'S TOILET

ENTRY DOOR

REQD SIGNAGE AT

WOMEN'S TOILET

ENTRY DOOR

REQD SIGNAGE AT

UNISEX TOILET

ENTRY DOOR

MEDICAL

GAS ALARM

PANEL

EQ EQ 1' - 0"

4'

/4

5'

EQ EQ 1' - 0"

5'

EQ EQ 1' - 0"

5'

1' - 0"

4'

1'

T O

U N

O B

S T

R U

C T

E D

C O

N T

R O

LS

4'

M

A X

H

IG

H R

E A

C H

3'

A T

M A

S O

N R

Y W

A

LL

S 3'

T

Y P

T O

C L

C O

N T

R O

LS

R E

A C

H

1'

M

IN

LO

W

T O

O B

S T

R U

C T

E D

C O

N T

R O

LS

3'

M

A X

H

IG

H R

E A

C H

COAT

HOOKS

(WALL-MTD)

COAT

HOOK

(DOOR-MTD)

CHALKBOARD,

TACKBOARD, OR DRY

MARKER BOARD

LOW LEVEL EXIT SIGN

(WHERE OCCURS) AT

EXIT DOOR

TACTILE

EXIT SIGN -

REFER TO

TO NOTE "L"

CEILING LINE

EXIT

EXIT

EXIT

6"

5'

3'

EQ EQ

6'

7'

6"

4"

TACTILE

EXIT SIGN -

REFER TO

TO NOTE "L"

4" EQ EQ

2"

1'

O R

G R

E A

T E

R

M O

U N

T O

N S

T R

IK

E

S

ID

E

A

LI

G N

W

IT

H T

O P

O F

A D

JA

C

E N

T F

R A

M E

W H

E N

D

IM

A B

O V

E D

O O

R H

E A

D

2"

IS

2" O

R G

R E

A T

E R

LO

C

A T

E

A

B O

V E

D O

O R

F R

A M

E W

H E

N D

IM

A

B O

V E

D O

O R

H E

A D

FEC OR

FHV

CABINET

ELECTRICAL

PANELBOARD

(FLUSH MTD)

ELECTRICAL

PANELBOARD

(SURFACE MTD)

6'

6'

2'

M A

X

WALL-MOUNTED

EXIT SIGN AT

EXIT DOOR

- CONTINUED AT TOP OF NEXT COLUMN

D.

5.

DIMENSION, WHEN OCCURS

ALIGN

B.

C.

B.

A.

4.

3.

A.

F.

E.

D.

1.

2.

E.

NOTE NO 4 CONTINUED:4.

C.

EXCEPT WHERE DIRECTED TO PLACE ITEMS OF THE

WORK AT THE "APPROXIMATE LOCATION SHOWN,"

DO NOT SCALE DRAWINGS FOR DIMENSIONAL

INFORMATION.

ALL ELEMENTS OF THE DRAWINGS MAY NOT BE

DRAWN TO EXACT SCALE. ALL DIMENSIONS

REQUIRED ARE SHOWN (OR MAY BE DERIVED

FROM THOSE SHOWN OR NOTED) ON THE FLOOR

PLANS, DETAIL PLANS, ELEVATIONS, SECTIONS,

SCHEDULES, CONFIGURATION DETAILS, AND

SPECIFICATIONS. SEE THE NOTES BELOW AND

SYMBOLS ON SHEET A001 FOR DIMENSIONING

CONVENTIONS USED ON THIS PROJECT.

EXCEPT WHERE SPECIFICALLY NOTED TO THE

CONTRARY, ALL DIMENSIONS SHOWN ON THE

ARCHITECTURAL DRAWINGS CONFORM TO THE

FOLLOWING CONVENTIONS:

DIMENSIONS UTILIZING THE "CENTERLINE" SYMBOL

ARE MEASURED TO:

STRUCTURAL OR DIMENSIONAL GRID LINES.

CENTERLINE OF CONCRETE OR CONC

MASONRY UNIT WALLS (EXCLUSIVE OF

FURRING OR APPLIED FINISHES HAVING

THICKNESS). REFER TO THE ARCH PLANS

AND SECTIONS, THE STRUCT DRAWINGS,

OR PARTITION SCHEDULE TO DETERMINE

THE THICKNESS OF CONCRETE OR CONC

MASONRY UNIT WALLS.

CENTERLINE OF PARTITION ASSEMBLY

(EXCLUSIVE OF ANY APPLIED FINISHES

HAVING THICKNESS WHICH MAY BE

ADDED TO SUCH WALLS) AT PARTITIONS

FRAMED WITH METAL STUDS. REFER TO

"PARTITION SCHEDULE" TO DETERMINE

THICKNESS OF EACH PARTITION TYPE.

CENTERLINE OF DOOR, WINDOW, OR LOUVER

OPENING.

CENTERLINE OF EQUIPMENT OR

FURNISHING.

CENTERLINE OF OTHER FEATURES AS

INDICATED.

REFER TO SHEET A001 FOR SYMBOL USED

TO INDICATE CENTERLINE DIMENSION.

DIMENSIONS UTILIZING THE "FACE OF"

SYMBOL ARE MEASURED TO:

FACE OF CONCRETE OR CONC MASONRY

UNIT WALL (EXCLUSIVE OF APPLIED

FINISHES HAVING THICKNESS OR FURRING

WHICH MAY BE ADDED TO THE FACE OF

SUCH WALLS).

FACE OF PARTITION ASSEMBLY

(EXCLUSIVE OF ANY APPLIED FINISHES

HAVING THICKNESS WHICH MAY BE

ADDED TO SUCH WALL) AS DEFINED

BY THE PARTITION SCHEDULE.

UNLESS NOTED AS A "FACE OF

FINISH" OR "CLEAR" DIMENSION (SEE

NOTE 'E' BELOW), DIMENSIONS ARE

NOT MEASURED TO THE FACE OF

APPLIED FINISH. REFER TO THE

"PARTITION SCHEDULE" TO DETERMINE

THE THICKNESS OF EACH PARTITION

TYPE.

INSIDE EDGE OF FINISHED DOOR

OPENING. REFER TO THE "DOOR

SCHEDULE" FOR ADDITIONAL

DIMENSIONAL INFORMATION.

DIMENSION OR WORK POINT AS

INDICATED ON RELATED ARCH DETAIL

PLAN, SECTION, ELEVATION, LAYOUT

OR CONFIGURATION DETAIL, OR

CONSTRUCTION DETAIL.

REFER TO SHEET A001 FOR SYMBOL USED

TO INDICATE "FACE OF" DIMENSION.

WHERE "FACE OF FINISH" OR "CLEAR" DIMENSIONS

ARE SPECIFICALLY NOTED, THE DIM IS MEASURED

TO:

FINISH FACES AT THE MOST NARROW

OR CONSTRICTED POINTS OF SECTION

WHERE DIMENSION IS SHOWN, WHEN

THE DIMENSION OCCURS ACROSS AN

OPEN SPACE. THIS CASE, A "FACE

OF FINISH" DIMENSION IS EQUIVALENT

TO A "CLEAR" DIMENSION.

FINISH FACES AT THE WIDEST OR MOST

EXPANSIVE POINTS OF THE SECTION THE

DIMENSION IS SHOWN WHEN THE DIMENSION

OCCURS ACROSS AN OBJECT OR GROUP OF

OBJECTS.

WHERE "EQUAL" DIMENSIONS ARE USED

ON REFLECTED CEILING PLANS TO

LOCATE CEILING GRID WORK POINTS,

MEASURE DIMENSIONS TO:

EDGE OF THE INDICATED CEILING AT

THE FACE OF THE ADJACENT APPLIED

FINISH MEASURED AT THE PLANE OF

THE CEILING.

CAUTION: DUE TO THE POSSIBLE

APPLICATION OF APPLIED FINISHES -

THICKNESS OF WHICH MAY VARY

BETWEEN FLOOR AND CEILING AND IS

NOT ACCOUNTED FOR (EXCEPT AS

INDICATED BY "FOF" OR "CLEAR") BY

THE DIMENSION SHOWN ON THE FLOOR

PLANS - THE CONTRACTOR MUST

ADJUST, AS NECESSARY, THE FLOOR

PLAN DIMENSIONS TO REFLECT THE

ACTUAL DIMENSIONS FOUND AT PLANE

OF THE CEILING.

WHERE DIMENSIONS ARE NOT PROVIDED ON

FLOOR PLANS TO LOCATE DOOR OPENINGS,

APPLY THE FOLLOWING RULES, IN ORDER, TO

DETERMINE THE LOCATION OF DOOR OPENINGS:

DOOR OPENINGS MAY BE

DIMENSIONED ON DRAWINGS OTHER

THAN THE FLOOR PLANS. REFER TO

THE SECTIONS, ELEVATIONS, DETAILS,

AND DOOR SCHEDULE NOTES FOR

ADDITIONAL DIMENSIONAL

INFORMATION.

WHERE THE HINGE-SIDE OF A DOOR IS

SHOWN ADJACENT TO A WALL - OR WALLS

- PERPENDICULAR TO THE WALL IN WHICH

THE DOOR OPENING OCCURS:

AT DOORS OCCURRING IN METAL FRAMED

GYPSUM BOARD PARTITIONS, LOCATE THE

HINGE-SIDE OF THE DOOR FINISHED

OPENING 4 INCHES FROM THE FACE

(EXCLUSIVE OF APPLIED FINISHES) OF THE

THE CLOSEST PERPENDICULAR WALL OR

PARTITION ASSEMBLY.

AT DOORS OCCURRING IN WALLS OF CONC

MASONRY UNIT CONSTRUCTION, LOCATE

THE HINGE-SIDE OF THE DOOR FINISHED

OPENING 10 INCHES FROM THE FACE

(EXCLUSIVE OF APPLIED FINISHES) OF THE

THE CLOSEST PERPENDICULAR WALL OR

PARTITION ASSEMBLY.

WHERE DOOR OCCURS NOT ADJACENT TO A

PERPENDICULAR WALL AND EITHER "DIM E"

OR "DIM F" IS 16'-0" OR LESS, LOCATE

DOOR UTILIZING THE FOLLOWING MINIMUM

DIMENSIONS:

DIMENSION A = 18 INCHES MIN

DIMENSION B = 12 INCHES MIN

DIMENSION C = DOOR WIDTH + 2

INCHES MINIMUM

DIMENSION D = 4 INCHES MIN AT

METAL FRAMED GYP BD PARTITIONS

OR - EVEN MULTIPLE OF 1/2 CMU

MODULE PLUS 2 INCHES AT CONC

MASONRY UNIT WALLS

DIMENSIONS E AND F = AS SHOWN ON

PLANS

DIMENSION G = 36 INCHES MIN

DIMENSION H = 60 INCHES MIN

IF SPACE ALLOWS, CENTER DOOR IN

WALL SHOWN ON THE DRAWINGS SO

THAT EITHER "DIM A" EQUALS "DIM C"

OR "DIM B" EQUALS "DIM D".

IF "DIM E" IN DIAGRAMS BELOW IS LESS

THAN THE SUM OF 2 TIMES THE DOOR

WIDTH PLUS 20 INCHES, LOCATE DOOR

SO THAT MINIMUMS STATED BY NOTE

NO 4C ABOVE FOR "DIM A", "DIM B,"

AND "DIM D" ARE MET - MAXIMIZING

"DIM A" AND MINIMIZING "DIM D" TO

THE EXTENT POSSIBLE.

WHERE DOOR IS SHOWN LOCATED IN A

LARGE EXPANSE OF OPEN WALL ("DIM

E" AND "DIM F" IN DIAGRAM BELOW

BOTH EXCEED 16'-0"), PLACE DOOR

AT APPROXIMATE LOCATION SHOWN ON

THE PLANS. WHERE DOOR OCCURS IN

CMU WALL, PLACE DOOR AT

APPROXIMATE LOCATION SHOWN WHILE

MINIMIZING "CUT" OR PARTIAL CMU

MODULES ADJACENT TO THE JAMBS.

WHERE WALLS AND/OR PARTITIONS OF

UNEQUAL THICKNESS ABUT, ALIGN EXPOSED

FACES, UNLESS OTHERWISE NOTED.

3. NOTE NO 3 CONTINUED:

MEASURED AT CLG PLANE

"EQUAL" DIM AT CEILING

MEASURED TO FACE OF PTN

TYPICAL DIM ON CEILING PLAN

4"

4"

10"

10"

DIM E > 16'-0"

DIM F > 16'-0"

E

A

E

A D

B D B

E

A C

F

B D

G

H

- CONTINUED AT TOP OF NEXT COLUMN

3. NOTE NO 3 CONTINUED: NOTE NO 4 CONTINUED:4.

- CONTINUED AT TOP OF NEXT COLUMN

- CONTINUED AT TOP OF NEXT COLUMN

SHEET NUMBER

PROJECT NUMBER

SHEET TITLE

SEALS AND SIGNATURES

ISSUED FOR REV DATE

1700 NEW YORK AVENUE NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 smithgroup.com

P lo t D at e

USHMM CONFERENCE

ROOM UPGRADE

1201 Maryland Ave SW Washington, DC 20024

7/

/2

1:

:2

P

M

TYPICAL MOUNTING

HEIGHTS AND

DIMENSIONING

CONVENTIONS

A002

S T

A R

T S he e t

12241

GENERAL MOUNTING

HEIGHT NOTES

TYPICAL MOUNTING HEIGHTS AND CLEARANCES

ARCHITECTURAL DIMENSIONING CONVENTIONS

GENERAL MOUNTING

HEIGHT NOTES

TYPICAL MOUNTING HEIGHTS AND CLEARANCES

ARCHITECTURAL DIMENSIONING CONVENTIONS

GRID

GRID

GRID

GRIDGRID

GRID

GRID

GRIDGRID

GRID

LOCATE ITEMS AS INDICATED WHEN SHOWN DIMENSIONED

(BOTH HORIZ AND VERT) BY AN ELEVATION, SECTIONAL

ELEVATION, OR DETAIL ELEVATION.

SPECIFIC DIMENSIONS SHOWN BY ELEVATIONS, SECTIONAL

ELEVATIONS, OR DETAIL ELEVATIONS TAKE PRECEDENCE

OVER TYPICAL MOUNTING HEIGHTS AND LOCATION RULES.

SPECIFIC MOUNTING DIMENSIONS SHOWN BY ELEVATIONS,

SECTIONAL ELEVATIONS, OR DETAIL ELEVATIONS TAKE

PRECEDENCE OVER CONFLICTING DIMENSIONS, IF ANY,

SHOWN ON PLANS OR DETAIL PLANS.

WHEN COMPLETELY DIMENSIONED IN ELEVATION

RULE 1

LOCATE ITEMS AS INDICATED WHEN SHOWN DIMENSIONED

(VERTICAL) BY AN ELEVATION, SECTIONAL ELEVATION, OR DETAIL

ELEVATION AND DIMENSIONED (HORIZONTAL) BY A PLAN OR

DETAIL PLAN.

SPECIFIC VERTICAL DIMENSIONS SHOWN BY ELEVATIONS,

SECTIONAL ELEVATIONS, OR DETAIL ELEVATIONS AND SPECIFIC

HORIZONTAL DIMENSION SHOWN BY PLANS AND DETAIL PLANS TAKE

PRECEDENCE OVER TYPICAL MOUNTING HEIGHTS AND LOCATION

RULES.

WHEN COMPLETELY DIMENSIONED BY COMBINATION OF PLAN AND ELEVATION

RULE 2

WHEN COMPLETELY DIMENSIONED ON PLANS

RULE 3

LOCATE ITEMS AS INDICATED WHEN SHOWN DIMENSIONED

(BOTH HORIZONTAL AND VERTICAL) BY A PLAN OR DETAIL

PLAN.

SPECIFIC VERTICAL DIMENSIONS SHOWN BY ELEVATIONS,

SECTIONAL ELEVATIONS, OR DETAIL ELEVATIONS AND SPECIFIC

HORIZONTAL DIMENSIONS SHOWN BY PLANS AND DETAIL PLANS

TAKE PRECEDENCE OVER TYPICAL MOUNTING HEIGHTS AND

LOCATION RULES.

NON-TYPICAL MOUNTING HEIGHTS MAY BE INDICATED BY

SYMBOL (AS SHOWN), BY KEYED NOTE, OR BY NOTATION ON

PLANS.

10'-6"C

C

C

WHEN DIMENSIONED HORIZONTALLY IN PLAN OR ELEVATION, BUT NOT DIMENSIONED VERTICALLY

RULE 4

LOCATE ITEMS AT TYPICAL MOUNTING HEIGHT WHEN NO VERTICAL

DIMENSION IS PROVIDED. LOCATE ITEMS AS INDICATED WHEN

HORIZONTAL DIMENSION IS PROVIDED BY ELEVATION, SECTIONAL

ELEVATION, DETAIL ELEVATION, PLAN, OR DETAIL PLAN.

SPECIFIC HORIZONTAL DIMENSIONS SHOWN BY ELEVATIONS, SECTIONAL

ELEVATIONS, DETAIL ELEVATIONS, PLANS, OR DETAIL PLANS TAKE

PRECEDENCE OVER TYPICAL MOUNTING LOCATION RULES.

WHEN NO DIMENSIONS ARE PROVIDED IN PLANS OR ELEVATIONS

RULE 5

UTILIZE TYPICAL MOUNTING CONFIGURATION DIAGRAMS PROVIDED

TO DETERMINE HORIZONTAL AND VERTICAL LOCATION OF ITEM OR

GROUP OF ITEMS IN RELATION TO OTHER, DIMENSIONED ITEMS.

SPECIFIC DIMENSIONS SHOWN BY TYPICAL MOUNTING

CONFIGURATION DIAGRAMS TAKE PRECEDENCE OVER

CONFIGURATIONS SHOWN WITHOUT DIMENSIONS ON ELEVATIONS.

SEE APPLICABLE TYPICAL CONFIGURATION DIAGRAM

IN EXAMPLE SHOWN, NURSE CALL LIGHT IS TYPICALLY LOCATED IN

RELATION TO TOP AND SIDE OF DOOR FRAME. THE DOOR LOCATION

MAY BE DETERMINED FROM DIMENSIONS SHOWN ON THE PLANS OR

THE PROJECT DIMENSIONING CONVENTIONS. THE DOOR AND FRAME

DIMENSIONS MAY BE DETERMINED FROM THE DOOR SCHEDULE.

C

NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER

RULE 6

WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR

PILASTER, AND WHEN NO OTHER TYPICAL CONFIGURATION

DIAGRAM APPLIES: HORIZONTALLY CENTER ITEM ON FACE OF

COLUMN OR PILASTER. ALIGN VERTICALLY CENTERS OF MULTIPLE

ITEMS HAVING DIFFERING TYPICAL MOUNTING HEIGHTS.

WHEN MULTIPLE ITEMS HAVING THE SAME TYP MOUNTING HEIGHT

ARE INDICATED, HORIZONTALLY CENTER GROUP OF ITEMS ON

FACE OF COLUMN OR PILASTER (SEE RULE 7).

ON PLANS, ITEMS TO BE

VERTICALLY ALIGNED MAY

BE SHOWN ADJACENT.

WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR

PILASTER, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM

APPLIES: HORIZONTALLY CENTER GROUP OF SIMILAR ITEMS HAVING THE

SAME MOUNTING HEIGHT(S) ABOUT THE CENTERLINE OF THE COLUMN OR

PILASTER.

WHEN APPLICABLE, COMBINE THIS RULE WITH RULE 6 TO

SYMMETRICALLY ARRANGE GROUPS OF ITEMS HAVING BOTH DIFFERING

AND SIMILAR MOUNTING HEIGHTS.

ARRANGE ITEMS AT SAME HEIGHT

SYMMETRICALLY ABOUT

CENTERLINE

NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER

RULE 7

WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR

PILASTER, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM

APPLIES: HORIZONTALLY CENTER GROUP OF DISSIMILAR ITEMS HAVING

CONFLICTING MOUNTING HEIGHT(S) ABOUT THE CENTERLINE OF THE

COLUMN OR PILASTER.

WHEN APPLICABLE, COMBINE THIS RULE WITH RULE 6 AND/OR

RULE 7 TO SYMMETRICALLY ARRANGE GROUPS OF ITEMS HAVING

DIFFERING, SIMILAR, AND CONFLICTING MOUNTING HEIGHTS.

ARRANGE ITEMS AT CONFLICTING

HEIGHTS SYMMETRICALLY ABOUT

CENTERLINE

NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER

RULE 8

WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO

STRIKE SIDE OF DOOR, AND WHEN STRIKE-SIDE CLEARANCE IS

BETWEEN 12 INCHES AND 18 INCHES, AND WHEN NO OTHER TYPICAL

CONFIGURATION DIAGRAM APPLIES: MOUNT ITEMS IN RELATION TO

FRAME USING TYPICAL OFFSET DIMENSION. VERTICALLY ALIGN

CENTERS OF ITEMS MOUNTED AT DIFFERENT HEIGHTS.

STRIKE SIDE OF DOOR

LINE OF WALL OR OTHER RESTRICTION

ON STRIKE-SIDE OF DOOR

WHEN MULTIPLE ITEMS HAVING THE SAME TYPICAL

MOUNTING HEIGHT ARE INDICATED, MOUNT FIRST ITEM IN

RELATION TO FRAME USING TYPICAL OFFSET DIMENSION

AND PLACE REMAINING ADJACENT TO FIRST ON SIDE

OPPOSITE FRAME AS ILLUSTRATED BY THIS DIAGRAM. DO

NOT CROWD MULTIPLE ITEMS AGAINST WALL OR

RESTRICTION.

NOT DIMENSIONED AND LOCATED ADJACENT TO MINIMUM STRIKE-SIDE OF DOOR

RULE 9

WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO

DOOR, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM

APPLIES: MOUNT ITEMS IN RELATION TO FRAME USING TYPICAL

OFFSET DIMENSION. VERTICALLY ALIGN CENTERS OF ITEMS

MOUNTED AT DIFFERENT HEIGHTS.

WHEN MULTIPLE ITEMS HAVING THE SAME TYPICAL MOUNTING

HEIGHT ARE INDICATED, MOUNT FIRST ITEM IN RELATION TO

FRAME USING TYPICAL OFFSET DIMENSION AND PLACE REMAINING

ITEMS ADJACENT TO FIRST ON SIDE OPPOSITE FRAME AS

ILLUSTRATED BY THIS DIAGRAM.

MULTIPLE ITEMS AT SAME

HEIGHT

WHEN PROVIDED, UTILIZE TYPICAL

MOUNTING DIAGRAMS TO DETERMINE

DIMENSIONS

SIMILAR RULE APPLIES WHEN ADJACENT TO WINDOW.

FOR PURPOSES OF THESE RULES, ITEMS SHOWN

LOCATED APPROXIMATELY WITHIN 4 FEET OF DOOR ARE

CONSIDERED TO BE ADJACENT TO DOOR (OR WINDOW).

WHERE MULTIPLE DISSIMILAR ITEMS HAVING

CONFLICTING MOUNTING HEIGHTS OCCUR, RULE 13 ALSO

APPLIES.

NOT DIMENSIONED AND LOCATED ADJACENT TO DOOR OR WINDOW

RULE 10

WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO DOOR,

AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM APPLIES:

MOUNT ITEMS IN RELATION TO SWING USING TYP OFFSET DIMENSION.

VERTICALLY ALIGN CENTERS OF ITEMS MOUNTED AT DIFFERENT

HEIGHTS.

WHEN MULTIPLE ITEMS HAVING THE SAME TYPICAL MOUNTING HEIGHT ARE

INDICATED, MOUNT FIRST ITEM IN RELATION TO SWING USING TYPICAL

OFFSET DIMENSION AND PLACE REMAINING ITEMS ADJACENT TO FIRST ON

SIDE OPPOSITE FRAME AS ILLUSTRATED BY THIS DIAGRAM.

MULTIPLE ITEMS AT SAME

HEIGHT

DOOR WHEN SWUNG AGAINST

WALL

FOR PURPOSES OF THESE RULES, ITEMS SHOWN

LOCATED APPROXIMATELY WITHIN 4 FEET OF OPEN

DOOR ARE CONSIDERED TO BE ADJACENT TO DOOR.

WHERE MULTIPLE DISSIMILAR ITEMS HAVING

CONFLICTING MOUNTING HEIGHTS OCCUR, RULE 13

ALSO APPLIES.

NOT DIMENSIONED AND LOCATED ADJACENT TO DOOR AND ON WALL AGAINST WHICH DOOR SWINGS

RULE 11

WHEN NOT DIMENSIONED AND LOCATED ADJACENT TO CHANGE IN WALL DIRECTION

RULE 12

WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT…

This is the start of the file's text. The full file is on GovTribe.