EXHIBIT IIA_Classroom_Reno_-_Permit_Set.pdf
PDF 16 MB Posted
- Solicitation number
- 95476724R0206
- Issued by
-
United States Holocaust Memorial Museum
About this file
This document appears to be the EXHIBIT IIA_Classroom_Reno_-_Permit_Set.pdf file related to the USHMM Classrooms A-D/Portals 2-000A AV Systems Modernization Project federal contract opportunity.
The key details are: The United States Holocaust Memorial Museum (USHMM) is seeking an experienced engineering/integration company to implement a modernized audio-visual infrastructure design in five of the museum's classroom/multipurpose, flexible use conferencing spaces. The work involves installation of hardware, cabling, software configuration, and control system programming. Offerors are expected to have demonstrated expertise in similar types of systems. A mandatory site visit is scheduled for June 17, 2024, and proposals are due by July 10, 2024. All RFP questions must be emailed by June 21, 2024. The solicitation contact is Mary Green, Contract Specialist at USHMM.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P lo t D at e
ISSUE DATE:
100 RAOUL WALLENBERG PLACE, SW.
WASHINGTON, DC 20024-2126
202.488.0400 ushmm.org
VOLUME I OF I
ISSUED FOR:
100%/PERMIT SET
1700 NEW YORK AVENUE NW
SUITE 100
WASHINGTON, DC 20006
202.842.2100 smithgroup.com
100 RAOUL WALLENBERG PLACE, SW.
WASHINGTON, DC 20024-2126
7/
/2
:4 5:
P
M
USHMM CLASSROOMS UPGRADE
02.26.2024
The United States Holocaust Memorial Museum
12241
EXHIBIT IIa
PROJECT SCOPE INCLUDES DOOR, AV AND LIGHTING UPGRADE. NO CHANGE OF USE OR OCCUPANCY.
THE FOLLOWING PROJECT GENERAL NOTES APPLY TO THE
ENTIRE DRAWING SET AND ARE NOT SPECIFIC TO ANY ONE
DISCIPLINE, UNLESS OTHERWISE NOTED:
1. THE DRAWING SET AND SPECIFICATIONS (PROJECT
MANUAL) ARE COMPLEMENTARY AND ESTABLISH
DETAILED MINIMUM REQUIREMENTS FOR THE DESIGN AND
CONSTRUCTION OF THE PROJECT.
2. THE DRAWING SET CONSISTS OF ALL SHEETS LISTED BY
THE SHEET INDEX. THE WORK DESCRIBED BY THE
DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY
THE WORK DESCRIBED ON DRAWINGS OF ANOTHER
DISCIPLINE AND MAY REQUIRE REFERENCE TO DRAWINGS
OF ANOTHER DISCIPLINE. AS SUCH, DO NOT DISTRIBUTE
OR UTILIZE PARTIAL SETS OF DRAWINGS.
3. COLUMN GRID LINES IDENTIFIED BY A LETTER
DESIGNATION ARE PARALLEL, UNLESS OTHERWISE
NOTED. COLUMN GRID LINES IDENTIFIED BY A NUMBER
DESIGNATION ARE PARALLEL AND ARE PERPENDICULAR
TO THOSE WITH LETTER DESIGNATIONS, UNLESS
OTHERWISE NOTED.
4. DISCIPLINE GENERAL NOTES, SYMBOLS AND DEFINITIONS
APPLICABLE TO EACH DISCIPLINE'S DRAWINGS MAY BE
FOUND AT THE FRONT OF EACH DISCIPLINE'S PORTION OF
THE DRAWING SET AND ARE LISTED IN THE SHEET INDEX.
5. UNLESS INDICATED OTHERWISE, THE 'ARCHITECTURAL'
SERIES DRAWINGS TAKE PRECEDENCE FOR THE FINISHED
APPEARANCE AND LOCATION OF ALL EXPOSED ELEMENTS
OF THE WORK OF ALL TRADES, INCLUDING THAT WORK
WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF
OTHER DISCIPLINES.
6. THE DRAWINGS MAY MAKE REFERENCE TO OR
ILLUSTRATE ITEMS WHICH ARE NOT PART OF THE WORK
OF THE CONTRACT. THESE "NOT IN CONTRACT" ITEMS AS
INDICATED ARE REFERENCED OR ILLUSTRATED FOR THE
CONTRACTOR'S REFERENCE, INFORMATION AND
COORDINATION ONLY.
7. EXISTING CONDITIONS, IF SHOWN, ARE FROM AVAILABLE
RECORD DRAWINGS AND/OR VISUAL FIELD SURVEYS.
VERIFY ACTUAL EXISTING CONDITIONS AT THE SITE PRIOR
TO SUBMITTING A BID. NOTIFY THE ARCHITECT, IN
WRITING AND PRIOR TO SUBMITTING A BID, OF ANY
DISCREPANCIES.
8. TAKE PRECAUTIONS TO MAINTAIN AND PROTECT NEW
WORK AS WELL AS EXISTING SYSTEMS AND ELEMENTS, IF
ANY, WHICH ARE TO REMAIN OR BE SALVAGED. ANY
DAMAGE TO SUCH SYSTEMS AND ELEMENTS SHALL BE
IMMEDIATELY REPAIRED IN A MANNER ACCEPTABLE TO
THE ARCHITECT. IF SATISFACTORY REPAIRS CANNOT BE
MADE, REPLACE SYSTEMS AND ELEMENTS WITH "LIKE
NEW" QUALITY ACCEPTABLE TO THE ARCHITECT, ALL AT
NO ADDITIONAL COST.
9. ALL PARTS OF THE WORK, INCLUDING BUT NOT
LIMITED TO MATERIALS, METHODS, OR ASSEMBLIES,
MUST COMPLY WITH THE REQUIREMENTS OF THE
GOVERNING CODES AND REGULATIONS OF ALL
FEDERAL, STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT, AS WELL AS
THOSE GREATER REQUIREMENTS INDICATED BY THE
CONTRACT DOCUMENTS. NO PART OF THE CONTRACT
DOCUMENTS MAY BE CONSTRUED TO REQUIRE OR
ALLOW WORK CONTRARY TO A GOVERNING CODE OR
REGULATION.
10. IDENTIFY AND NOTIFY THE ARCHITECT OF CONFLICTS
BETWEEN THE WORK OF DIFFERENT PARTIES AT THE
EARLIEST POSSIBLE DATE SO AS TO ALLOW
REASONABLE AND ADEQUATE TIME FOR THE
CONFLICT TO BE RESOLVED WITHOUT DELAYING THE
WORK. ALL DEVIATIONS FROM THE CONTRACT
DOCUMENTS MUST BE APPROVED IN ADVANCE BY THE
ARCHITECT AND OWNER.
11. REVIEW AND COORDINATE THE WORK OF ALL OTHER
PARTIES PERFORMING WORK AT THE PROJECT,
INCLUDING BUT NOT LIMITED TO, DELEGATED DESIGN
ENTITIES, TRADES AND SUPPLIERS WITH THE
REQUIREMENTS OF THE CONTRACT DOCUMENTS
BEFORE COMMENCING CONSTRUCTION, AND ASSURE
THAT ALL PARTIES ARE AWARE OF ALL
REQUIREMENTS, REGARDLESS OF WHERE THE
REQUIREMENTS OCCUR IN THE CONTRACT
DOCUMENTS, WHICH MIGHT AFFECT THE WORK OF
THAT PARTY.
A
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
SEALS AND SIGNATURES
ISSUED FOR REV DATE
1700 NEW YORK AVENUE NW
SUITE 100
WASHINGTON, DC 20006
202.842.2100 smithgroup.com
P lo t D at e
USHMM CLASSROOMS
UPGRADE
100 Raoul Wallenberg Pl SW Washington, DC, 20024
7/
/2
:5 7:
A
M
PROJECT SHEET INDEX
AND GENERAL PROJECT
INFORMATION - MUSEUM
G101
S T
A R
T S he e t
12241
PROJECT GENERAL
NOTES
VICINITY MAP
OWNER / CLIENT:
UNITED STATES HOLOCAUST MEMORIAL MUSEUM
100 RAOUL WALLENBERG PI SW
WASHINGTON / DC / 20024
T: 202.488.0400
WEBSITE: USHMM.ORG
ARCHITECT:
SMITHGROUP
1700 NEW YORK AVENUE NW
SUITE 100
WASHINGTON / DC / 20006
T: 202.842.2100 WEBSITE: smithgroup.com
MECHANICAL ENGINEER:
SMITHGROUP
1700 NEW YORK AVENUE NW
SUITE 100
WASHINGTON / DC / 20006
T: 202.842.2100 WEBSITE: smithgroup.com
ELECTRICAL ENGINEER:
SMITHGROUP
1700 NEW YORK AVENUE NW
SUITE 100
WASHINGTON / DC / 20006
T: 202.842.2100 WEBSITE: smithgroup.com
AV/ IT/ ACOUSTICS:
ARUP USA, Inc
1120 CONNECTICUT AVENUE NW
SUITE 1110
WASHINGTON / DC / 20036
T: 202.729.8220 WEBSITE: www.arup.com
PROJECT TEAM
PROJECT DESCRIPTION
PROJECT SHEET INDEX
SHEET NUMBER SHEET NAME
GENERAL
G000 PROJECT COVER SHEET - MUSEUM
G101 PROJECT SHEET INDEX AND GENERAL PROJECT INFORMATION - MUSEUM
G211 BUILDING CODE SUMMARY - MUSEUM
ARCHITECTURAL
A001 ARCHITECTURAL ABBREVIATIONS AND SYMBOLS
A002 TYPICAL MOUNTING HEIGHTS AND DIMENSIONING CONVENTIONS
A003 TYPICAL RULES FOR DETERMINING MOUNTING HEIGHTS AND LOCATIONS
A004 TYPICAL REFLECTED CEILING PLAN LOCATIONS AND CONFIGURATIONS
AD201 GROUND LEVEL DEMOLITION FLOOR PLAN
AD202 ENLARGED DEMOLITION PLANS & INTERIOR ELEVATIONS
A211 MUSEUM FLOOR PLAN
A721 ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS
A721.1 ALTERNATES - ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS
A722 ENLARGED REFLECTED CEILING PLAN & FINISH PLANS, SCHEDULE
A921 DOOR AND FRAME ELEVATIONS AND SCHEDULE, PARTITION SYSTEMS
A961 MILLWORK AND INTERIOR DETAILS
ELECTRICAL
E001 ELECTRICAL ABBREVIATIONS AND SYMBOLS
E002 ELECTRICAL SCHEDULES
E201 FLOOR PLAN OVERALL - CLASSROOM
E500 ELECTRICAL DIAGRAMS, LIGHTING POWER DENSITY & FIXTURE & PANEL SCHEDULE - CLASSROOM
E600 ELECTRICAL DETAILS - CLASSROOM
E601 ELECTRICAL DETAILS - CLASSROOM
AV-701 AUDIOVISUAL GENERAL DETAILS SHEET 2
AV-700 AUDIOVISUAL GENERAL DETAILS SHEET 1
AV-603 PORTABLE PRODUCTION CART FUNCTIONAL
AV-601 AUDIOVISUAL CLASSROOM ENHANCED FUNCTIONAL
AV-600 AUDIOVISUAL CLASSROOM STANDARD FUNCTIONAL
AV-500 AUDIOVISUAL PLATE DETAILS
AV-301 AUDIOVISUAL ENLARGED CLASSROOM RCP (B&C, D)
AV-300 AUDIOVISUAL ENLARGED CLASSROOM RCP (A)
AV-201A AUDIOVISUAL ENLARGED CLASSROOM PLANS (B&C, D) - ALTERNATES
AV-201 AUDIOVISUAL ENLARGED CLASSROOM PLANS (B&C, D)
AV-200A AUDIOVISUAL ENLARGED CLASSROOM PLANS (A) - ALTERNATES
AV-200 AUDIOVISUAL ENLARGED CLASSROOM PLANS (A)
AV-100 AUDIOVISUAL OVERALL MUSEUM PLAN
AV-000 AUDIOVISUAL GENERAL NOTES, SYMBOLS, & ABBREVIATIONS
AV
A. THE PURPOSE OF THE FIRE AND LIFE SAFETY DRAWINGS IS TO
ILLUSTRATE IN SCHEMATIC FASHION, THE APPLICABLE
EXITING, FIRE-RESISTANCE, AND LIFE SAFETY CONCEPTS
UTILIZED BY THIS PROJECT; INCLUDING, BUT NOT LIMITED TO:
• OCCUPANCY CLASSIFICATIONS
• OCCUPANCY LOAD FACTORS
• EXIT LOCATIONS, EXIT PATHS & CAPACITY - FUNCTION OF
SPACE
• FIRE-RESISTANCE RATED CONSTRUCTION
• AND OTHER STRATEGIES RELATED TO THE CODE
COMPLIANCE APPROACH OF THIS PROJECT.
B. ADDITIONAL DETAILED REQUIREMENTS APPLY TO THE
CONSTRUCTION OF PARTITIONS, FIRE RATED DOOR
ASSEMBLIES, INTERIOR GLAZED OPENINGS, DUCTS, SMOKE
AND FIRE DAMPERS AND THROUGH PENETRATION FIRE
STOPPING. REFER TO THE DRAWINGS OF EACH DISCIPLINE
AND THE SPECIFICATIONS FOR THESE REQUIREMENTS.
C. ADDITIONAL DETAILED REQUIREMENTS SHOWN ELSEWHERE
MAY REQUIRE CONSTRUCTION HAVING GREATER FIRE
RATINGS, MORE EXTENSIVE FIRE-RATED CONSTRUCTION,OR
MORE COMPLEX ASSEMBLIES THAN INDICATED BY THE
DIAGRAMS ON THIS SHEET. WHEN PROVIDED, THE ADDITIONAL
DETAILED REQUIREMENTS SHALL GOVERN.
E. FIRE BARRIERS SHALL EXTEND FROM THE TOP OF THE
FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO THE
UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR
DECK ABOVE AND SHALL BE SECURELY ATTACHED THERETO.
SUCH FIRE BARRIERS SHALL BE CONTINUOUS THROUGH
CONCEALED SPACES.
F. SHAFT ENCLOSURES SHALL BE CONSTRUCTED AS FIRE
BARRIERS.
G. FIRE PARTITIONS SHALL EXTEND FROM THE TOP OF THE
FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO THE
UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR
DECK ABOVE OR TO THE FIRE-RESISTANCE-RATED
FLOOR/CEILING OR ROOF/CEILING ASSEMBLY ABOVE, AND
SHALL BE SECURELY ATTACHED THERETO.
H. SMOKE BARRIERS SHALL FORM AN EFFECTIVE MEMBRANE
CONTINUOUS FROM OUTSIDE WALL TO OUTSIDE WALL AND
FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING
ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR
ROOF SHEATHING, DECK OR SLAB ABOVE, INCLUDING
CONTINUITY THROUGH CONCEALED SPACES.
J. SMOKE PARTITIONS SHALL EXTEND FROM THE TOP OF THE
FOUNDATION OR FLOOR BELOW TO THE UNDERSIDE OF THE
FLOOR OR ROOF SHEATHING, DECK OR SLAB ABOVE OR TO
THE UNDERSIDE OF THE CEILING ABOVE WHERE THE CEILING
MEMBRANE IS CONSTRUCTED TO LIMIT THE TRANSFER OF
SMOKE.
A. A SIGN COMPLYING WITH IBC SECTION 1111 SHALL BE
PROVIDED AT EACH LANDING OF THE ELEVATOR AND SAY THE
FOLLOWING: "IN FIRE EMERGENCY, DO NOT USE THE
ELEVATOR. USE EXIT STAIRS".
B. INTERIOR WALL & CEILING FINISHES SHALL HAVE A FLAME
SPREAD INDEX RATING OF NO MORE THAN CLASS B AT
VERTICAL EXITS & EXIT PASSAGEWAYS AND EXIT ACCESS
CORRIDORS AND OTHER EXITWAYS.
C. INTERIOR WALL & CEILING FINISHES SHALL HAVE A FLAME
SPREAD INDEX RATING OF NO MORE THAN CLASS C AT
ROOMS AND ENCLOSED SPACES.
D. ALL MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL
HAVE A FLAME SPREAD RATING INDEX NOT MORE THAN 25
AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 50.
E. FIRE EXTINGUISHERS SHALL BE LOCATED SUCH THAT A
MAXIMUM TRAVEL DISTANCE OF 75' SHALL NOT BE EXCEEDED
(WHERE REQUIRED BY CODE).
F. LEVEL/ AREA MAIN OCCUPANCY EXIT SIGN LOCATIONS MAY
NOT BE SHOWN. REFERENCE ELECTRICAL SHEETS FOR ALL
EXIT SIGN LOCATIONS.
G. FIRE RESISTIVE ASSEMBLY DETAILS, IF APPLICABLE, ARE
LOCATED ELSEWHERE IN THIS DRAWING SET PER THE SHEET
INDEX.
H. ELEVATOR HOISTWAY OPENINGS SHALL BE PROTECTED AS
REQUIRED BY THE CODE, CORRESPONDING TO THE RATING
OF THE HOISTWAY.
J. EVERY ASSEMBLY OCCUPANCY ROOM OR SPACE SHALL HAVE
THE OCCUPANT LOAD POSTED IN A CONSPICUOUS PLACE.
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
SEALS AND SIGNATURES
ISSUED FOR REV DATE
1700 NEW YORK AVENUE NW
SUITE 100
WASHINGTON, DC 20006
202.842.2100 smithgroup.com
P lo t D at e
USHMM CLASSROOMS
UPGRADE
100 Raoul Wallenberg Pl SW Washington, DC, 20024
7/
/2
:4 5:
P
M
BUILDING CODE
SUMMARY - MUSEUM
G211
A ut ho r
12241
GENERAL FIRE AND LIFE
SAFETY SHEET NOTES
ANTICIPATED DEFERRED SUBMITTALS
A. FIRE PROTECTION DESIGN
B. FIRE ALARM DESIGN
C. BUILDING SIGNAGE (NON CODE REQUIRED)
D. SECURITY SYSTEM DESIGN
E. CCTV, PA SYSTEM
F. FURNITURE SYSTEMS
G. PRE-MANUFACTURED STAIRS
H. EXTERIOR CURTAIN WALL SYSTEM
J. ----
DEFERRED SUBMITTALS
PROJECT FIRE AND LIFE
SAFETY SHEET NOTES
INTERNATIONAL BUILDING CODES
(IBC) INTERNATIONAL BUILDING CODE 2015
(IEBC) INTERNATIONAL REHABILITATION CODE 2015
(IECC) INTERNATIONAL ENERGY CONSERVATION CODE 2015
(IFC) INTERNATIONAL FIRE CODE 2015
(IMC) INTERNATIONAL MECHANICAL CODE 2015
(IPC) INTERNATIONAL PLUMBING CODE 2015
NATIONAL FIRE PROTECTION ASSOCIATION
NFPA 10 STANDARD FOR PORTABLE FIRE
EXTINGUISHERS
NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS 2013
NFPA 14 STANDARD FOR THE INSTALLATION OF
STANDPIPE AND HOSE SYSTEMS
NFPA 70 NATIONAL ELECTRICAL CODE 2014
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING
CODE
NFPA 101 LIFE SAFETY CODE 2015
ACCESSIBILITY GUIDELINES
ADA ADA STANDARDS FOR ACCESSIBLE DESIGN
BY THE U.S. DEPARTMENT OF JUSTICE
ICC/ANSI
117.1
ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES
ADDITIONAL GUIDELINES
ASME
A17.1
SAFETY CODE FOR ELEVATORS AND
ESCALATORS
CODES / STANDARDS
COMMON PATH OF EGRESS TRAVEL (IBC 1006.2.1)
OCCUPANCY SPRINKLERED MAX. DISTANCE
B YES 100' - 0"
R-2 YES 125' - 0"
EXIT ACCESS TRAVEL DISTANCE (IBC TABLE 1017.2)
OCCUPANCY SPRINKLERED MAX. DISTANCE
B YES 250' - 0"
DEAD ENDS (IBC 1020.4)
OCCUPANCY SPRINKLERED MAX. DISTANCE
B YES 50' - 0"
MIN. NUMBER OF EXITS FOR OCCUPANT LOAD (IBC TABLE 1006.3.2)
OCCUPANT LOAD MIN. # OF EXITS PER STORY
1-500 2
501-1,000 3
MORE THAN 1,000 4
PROJECT CODE SUMMARY CODE COMPLIANCE
APPROACH NARRATIVE
CODE COMPLIANCE APPROACH:
NO ALTERATION TO SPACE TYPE THEREFORE NO ADDITIONAL CODE
REVIEW REQUIRED.
APPLICABLE CODES/CRITERIA/DESIGN POLICY:
AUTHORITY HAVING JURISDICTION:
DISTRICT OF COLUMBIA DEPARTMENT OF BUILDINGS (DOB)
LIFE SAFETY SYSTEMS:
AUTOMATIC SPRINKLER SYSTEM : PROVIDED PER NFPA 13
ALTERNATIVE AUTOMATIC FIRE-
EXTINGUISHING SYSTEMS :
PROVIDED - REFER TO FIRE
PROTECTION DRAWINGS
STANDPIPE SYSTEM : PROVIDED PER NFPA 14: CLASS I
PORTABLE FIRE EXTINGUISHERS : PROVIDED PER NFPA 10
FIRE ALARM SYSTEM : PROVIDED PER NFPA 72
(PER IBC AND IFC CHAPTER 9)
0 < 3 FT
3 < 5 FT
5 < 10 FT
10 < 15 FT
15 < 20 FT
20 < 25 FT
25 < 30 FT
30 FT >
MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE
SEPARATION DISTANCE:
FIRE SEPARATION
DISTANCE (UP, NS) (UP, S) (P)
NP
NP
10% 15% 25% 45% 70%
NL
DEGREE OF PROTECTION
NP
15% 25% 45% 75%
NL
NL
NR
NP
15% 25% 45% 75%
NL
NL
NR
[PER IBC TABLE 705.8]
X < 5 FT
5 FT < X < 10 FT
10 FT < X < 30 FT
X > 30 FT
FIRE-RESISTANCE RATING FOR EXTERIOR WALLS BASED ON FIRE
SEPARATION DISTANCE {X} :
CONSTRUCTION
TYPE / OCCUPANCY IIB / B
1 HOURS
1 HOURS
0 HOURS
0 HOURS
2 HOURS
1 HOURS
2 HOURS
0 HOURS
1 HOURS
1 HOURS
1 HOURS
0 HOURS
1 HOURS
1 HOURS
1 HOURS
0 HOURS
IA / S-1 IIIA / A-3 VA / R-1
[PER IBC TABLE 602]
TYPE OF CONSTRUCTION:
PRIMARY STRUCTURAL FRAME :
BEARING WALLS (EXT) :
BEARING WALLS (INTR) :
NON-BRG WALLS AND PARTITIONS (EXT)
NON-BRG WALLS AND PARTITIONS (INTR) :
FLOOR CONSTR AND SECONDARY MEMBERS :
ROOF CONSTR AND SECONDARY MEMBERS :
IA
3 HOURS
3 HOURS
3 HOURS
0 HOURS
0 HOURS
2 HOURS
1.5 HOURS
IIB
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
0 HOURS
PER IBC TABLE 601:
MINIMUM FIRE-RESISTANCE REQUIREMENTS:
FIRE-RESISTIVE RATING REQUIREMENTS FOR BUILDING ELEMENTS :
[PER IBC TABLE 601]
BUILDING AREA CALCULATIONS:
UNLIMITED AREA ALLOWED
UNLIMITED HEIGHT ALLOWED
UNLIMITED AREA BUILDING
NONSPRINKLERED, ONE-STORY, 60 FOOT YARDS
SPRINKLERED, ONE-STORY ABOVE GRADE PLANE, 60' YARDS
SPRINKLERED, TWO STORIES ABOVE GRADE PLANE, 60' YARDS
AUTOMATIC SPRINKLER SYSTEM INCREASE USED FOR ALLOWABLE
HEIGHT MODIFICATION
20 FEET AND ONE STORY
NO ALLOWABLE HEIGHT OR AREA MODIFICATIONS USED
ALLOWABLE AREA MODIFICATIONS USED PER THE ALLOWABLE AREA
CALCULATIONS ON THIS SHEET:
BUILDING AREA MODIFICATIONS
FRONTAGE INCREASE
(PER IBC EQUATION 5-1)
(PER IBC 504.1)
(PER IBC TABLE 506.2)
(PER IBC EQUATION 5-2)
(PER IBC SECTION 507)
PER IBC CHAPTER 5
(PER IBC TABLE 504.3)
PROJECT CODE SUMMARY SYMBOLS
ITEM NOT SELECTED
ITEM SELECTED
BASIC OCCUPANCY GROUP(S) :
BUILDING CLASSIFICATION:
ACCESSORY OCCUPANCIES
[Accessory Occupancies <10% of Story]
INCIDENTAL USES
NONSEPARATED OCCUPANCIES*
SEPARATED OCCUPANCIES
*REFER TO FIRE AND LIFE SAFETY PLANS FOR SEPARATION
REQUIREMENTS
GROUP A-1 GROUP A-2 GROUP A-3
GROUP A-4 GROUP A-5 GROUP B
GROUP E GROUP F-1 GROUP F-2
GROUP H-1 GROUP H-2 GROUP H-3
GROUP H-4 GROUP H-5 GROUP I-1
GROUP I-2 GROUP I-3 GROUP I-4
GROUP M GROUP R-1 GROUP R-2
GROUP R-3 GROUP R-4 GROUP S-1
GROUP S-2 GROUP U
TYPE I : A B
TYPE II : A B
TYPE III : A B
TYPE IV : HT
TYPE V : A B
MIXED USE AND OCCUPANCY :
SPECIAL DETAILED REQUIREMENTS :
HIGH-RISE BUILDING
ATRIUM
OPEN PARKING GARAGE
GROUP I-2:
- SMOKE COMPARTMENTS
- REFUGE AREA
HAZARDOUS MATERIALS:
- CONTROL AREAS
MEZZANINE
EQUIPMENT PLATFORM
TYPE(S) OF CONSTRUCTION :
[PER IBC CHAPTER 3]
[PER IBC SECTION 508 & 509]
OCCUPANCY CLASSIFICATION AND CONSTRUCTION TYPES PER IBC
CHAPTERS 3, 4, 5, AND 6
[IBC 508.2]
[IBC 508.3]
[IBC 508.4]
[PER IBC CHAPTER 6]
[PER IBC SECTION 403]
[PER IBC SECTION 404]
[PER IBC SECTION 505]
[IBC SECTION 509]
[PER IBC SECTION 406.5]
[PER IBC SECTION 407]
[PER IBC SECTION 414]
[PER IBC SECTION 505]
SHAFT ENCLOSURES
FOUR STORIES OR MORE :
LESS THAN FOUR STORIES:
EXIT ENCLOSURES
FOUR STORIES OR MORE :
LESS THAN FOUR STORIES:
EXIT PASSAGEWAYS :
HOISTWAY ENCLOSURES :
ELEVATOR MACHINE ROOMS :
ADDITIONAL FIRE-RESISTIVE RATINGS :
DESCRIPTION CODE SECTION RATING (HR)
CORRIDORS:
OCCUPANCY: OCC LOAD SERVED: RATING (HR):
OCCUPANCY: OCC LOAD SERVED: RATING (HR):
SPRINKLERED:
NOTE: ALL SHAFT ENCLOSURES THAT PENETRATE FLOORS
RATED FOR 2 OR MORE HOURS SHALL BE 2-HOUR RATED SHAFTS
IBC 713
IBC 1023.2
IBC 1024.3
IBC 3002.1
IBC 3005.4
B >30 1
A All 1
[IBC TABLE 1020.1]
FIRE DOOR AND FIRE SHUTTER FIRE PROTECTION RATINGS (hours):
TYPE OF
ASSEMBLY
REQ'D
ASSEMBLY
RATING
MIN. FIRE DOOR
AND FIRE SHUTTER
ASSEMBLY RATING
Fire walls and fire barriers having a required fire-resistance rating greater than 1 hour
Fire barriers having a required fire-resistance rating of 1 hour
Fire partitions
Exterior Walls
Smoke Barriers
Shaft, exit enclosure and exit passageway walls:
Other fire barriers:
1 1/2
0.5
0.5
Corridor walls:
Other fire partitions:
1 1/2 1 1/2
3/4
1/3 1/3 3/4 1/3
1 1/2 1 1/2 3/4
1/3
[PER IBC TABLE 716.5]
MEANS OF EGRESS:
DOORS :
THE MINIMUM CLEAR WIDTH AND HEIGHT OF A DOOR SHALL NOT
BE LESS THAN 32 INCHES AND 80 INCHES RESPECTIVELY.
DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL,
WHERE SERVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS
OR A GROUP H OCCUPANCY.
*REFER TO THE LIFE SAFETY PLANS FOR ACTUAL MEASURED
DISTANCES.
[PER IBC 1008.1.1]
[PER IBC 1008.1.2]
EXIT CAPACITY FACTORS:
MINIMUM REQUIRED EGRESS WIDTH :
STAIRWAYS
OTHER EGRESS COMPONENTS
SPRINKLERED
EMERGENCY
VOICE/ALARM
COMMUNICATION
SYSTEM
*REFER TO THE LIFE SAFETY PLANS FOR COMPLIANCE WITH MEANS
OF EGRESS WIDTH REQUIREMENTS.
[PER IBC 1005.1]
0.3 0.2
BUILDING OCCUPANCY SUMMARY
GRAPHIC LEGEND
NO PROPOSED CHANGES TO OCCUPANCY; ONLY FINISH AND ELECTRICAL UPGRADES ARE REQUIRED.
100% / PERMIT SET 07.21.2023
AB
A
ANCHOR BOLT
ACT ACOUSTICAL CEILING TILE
ACP
AD
ACOUSTICAL CEILING PANEL
AREA DRAIN
ADDL ADDITIONAL
ADH
ADDITIONAL
ADJ
ADHESIVE
ADJ
ADJUSTABLE
AFF
ADJACENT
AFG
ABOVE FINISH FLOOR
AFS
ABOVE FINISH GRADE
AGGR
ABOVE FINISH SLAB
ALUM
AGGREGATE
ALT
ALUMINUM
ANOD
ALTERNATE
APPROX
ANODIZED
ARCH
APPROXIMATE(LY)
ACS PNL ACCESS PANEL
ARCHITECT(URAL)
ASPH ASPHALT
AVG AVERAGE
BB
B
BULLETIN BOARD
BD BOARD
BTWN
BLDG
BETWEEN
BUILDING
BM
BOT
BENCHMARK
BOTTOM
BITUM BITUMINOUS
BOS BOTTOM OF STEEL
BRG BEARING
BSMT BASEMENT
CAB
C
CABINET
CB CATCH BASIN
CCT
CG
CUBICLE CURTAIN TRACK
CORNER GUARD
CEM
CER
CEMENT, CEMENTITIOUS
CERAMIC
CCTV CLOSED CIRCUIT TELEVISION
CH BD CHALKBOARD
CI CAST IRON
CJ CONTROL JOINT
CL
CLG
CLR
CMU
CNTR
COL
CONC
CONF
CONN
CONSTR
CONT
CONTR
CORR
CPT
CSK
CSP
CSWK
CU
CW
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COUNTER
COLUMN
CONCRETE
CONFERENCE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CORRUGATED
CARPET
COUNTERSUNK
COMBINATION STANDPIPE
CASEWORK
CUBIC
COLD WATER
D
D
DEPTH
DBL DOUBLE
DBL ACT DOUBLE ACTING
DEG DEGREE
DEMO DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DIM PT DIMENSION POINT
DISP DISPENSER
DIST DISTANCE
DN DOWN
DR DRAIN
DS DOWNSPOUT
DSP DRY STANDPIPE
DT DRAPERY TRACK
DWG DRAWING
DWGS DRAWINGS
(E)
E
EXISTING
EA EACH
EDR EQUIPMENT DRAWING
EG EDGE GUARD
EIFS EXTERIOR INSULATION FINISH SYSTEM
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
EOS EDGE OF SLAB
EP ELECTRICAL PANEL
EPB ELECTRICAL PANEL BOARD
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ESCAL ESCALATOR
EST ESTIMATE(D)
EWC ELECTRIC WATER COOLER
EXC EXCAVATED
EXH EXHAUST
EXP EXPANSION
EXP JT EXPANSION JOINT
EXT EXTERIOR
F/F
F
FACE TO FACE
FA FIRE ALARM
FAS FIRE ALARM STATION
FB FLAT BAR
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FF FINISH FACE
FHC FIRE HOSE CABINET
FH/FEC FIRE HOSE / FIRE EXTINGUISHER CABINET
FHMS FLAT HEAD MACHINE SCREW
FHWS FLAT HEAD WOOD SCREW
FHY FIRE HYDRANT
FLAM FLAMMABLE
FLASH FLASHING
FLEX FLEXIBLE
FLUOR FLUORESCENT
FO FACE OF
FSB FOLDING SHOWER BENCH
FSTNR FASTENER
FT FOOT, FEET
FTG FOOTING
FURN FURNITURE
FXTR FIXTURE
G
G
GAS
H
H
HIGH
GA GAUGE, GAGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GLU LAM GLUE LAMINATED
GLZ GLAZING
GR GRADE OR GRADING
GVL GRAVEL
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
ID
I
INSIDE DIAMETER
JAN
J
JANITOR
KG
K
KILOGRAM
L
L
LENGTH, LONG
M
M
METERS
(N)
N
NEW
OC
O
ON CENTER
PA
P
PUBLIC ADDRESS
QT
Q
QUARRY TILE
R
R
RISER
S SOUTH
T
T
TREAD
VAC
V
VACUUM
W
W
WEST
XFMR
X
TRANSFORMER
YD
Y
YARD
HB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HDBD HARDBOARD
HDW HARDWARE
HDWD HARDWOOD
HGT HEIGHT
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HPT HIGH POINT
HR HOUR
HVAC HEATING-VENTILATION-AIR CONDITIONING
IN INCH
INCAND INCANDESCENT
INCL INCLUDE, INCLUDING
INFO INFORMATION
INSUL INSULATION
INTR INTERIOR
INV INVERT
IVT INTRAVENOUS TRACK
JST JOIST
JT JOINT
KIT KITCHEN
KPL KICK PLATE
KS KNEE SPACE
LAB LABORATORY
LAM LAMINATE, LAMINATION
LAV LAVATORY
LB POUND
LED LIGHT EMITTING DIODE
LF LINEAR FOOT
LG LENGTH
LIN LINEAR
LL LEAD LINED
LPT LOW POINT
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LVR LOUVER
HW HOT WATER S
MACH MACHINE
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MC MEDICINE CABINET
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOLDING
MM MILLIMETERS
MO MASONRY OPENING
MOD MODULE, MODULAR
MTD MOUNTED
MTG MOUNTING
MVBL MOVABLE
MULL MULLION
NA NOT APPLICABLE
NAT NATURAL
NE NORTHEAST
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOICE REDUCTION COEFFICIENT
NTS NOT TO SCALE
NW NORTHWEST
OA OVERALL
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED-CONTRACTOR INSTALLED
OFOI OWNER FURNISHED-OWNER INSTALLED
OPP OPPOSITE
ORD OVERFLOW ROOF DRAIN
OVHD OVERHEAD
OZ OUNCE
PART PARTIAL
PBD PARTICLEBOARD
PBX PRIVATE TELEPHONE EXCHANGE
PCF POUNDS PER CUBIC FOOT
PCI POUNDS PER CUBIC INCH
PERF PERFORATED
PERIM PERIMETER
PERM PERMANENT
PERP PERPENDICULAR
PI POINT OF INTERSECTION
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PNEU PNEUMATIC
PNL PANEL
PNL BD PANEL BOARD
PNT PAINT
PORT PORTABLE
PP PUSH PLATE
PPM PARTS PER MILLION
PR PAIR
PRCST PRECAST
PREP PREPARATION
PREFAB PREFABRICATION
PRKG PARKING
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTN PARTITION
PTS PNEUMATIC TUBE STATION
PVC POLYVINYL CHLORIDE
PVG PAVING
PVMT PAVEMENT
PWR POWER
QTR QUARTER
QTY QUANTITY
RA RETURN AIR
RAD RADIUS
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
RD ROOF DRAIN
RECT RECTANGULAR
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE (D) (ING) (MENT)
REQD REQUIRED
REQT REQUIREMENT
RESIL RESILIENT
RET RETURN
REV REVISION
RF RESILIENT FLOORING
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHWS ROUND HEAD WOOD SCREW
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RWL RAIN WATER LEADER
SA SUPPLY AIR
SB SPLASH BLOCK
SC SOLID CORE
SCHED SCHEDULE
SCRN SCREEN
SD STORM DRAIN
SE SOUTHEAST
SECT SECTION
SEG SEGMENT
SEP SEPARATION OR SEPARATE
SEP JT SEPARATION JOINT
SHT SHEET, SHEETING
SHWR SHOWER
SHV SHELVES, SHELVING
SIM SIMILAR
SK SINK
SMS SHEET METAL SCREW
SP SPACE, SPACED, SPACING
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS SANITARY SEWER
SSK SERVICE SINK
SST STAINLESS STEEL
ST STREET
STA STATION
STAG STAGGERED
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
STS SELF-TAPPING STEEL
SUSP SUSPENDED
SUSP CLG SUSPENDED CEILING
SVCE SERVICE
SW SOUTHWEST
SYMM SYMMETRICAL
SYST SYSTEM
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TC TOP OF CONCRETE, TOP OF CURB
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
THERM THERMAL
THK THICK, THICKNESS
THRES THRESHOLD
THRU THROUGH
TMPD GL TEMPERED GLASS
TO TOP OF
TOR TOP OF RAILING
TOS TOP OF STEEL
TOT TOTAL
TOW TOP OF WALL
TP TOP OF PAVEMENT
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
UC
U
UNDER COUNTER
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTABLE POWER SUPPLY
UTIL UTILITY
VB VALVE BOX
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIT VITREOUS
VP VENT PIPE
VOL VOLUME
VWC VINYL WALL COVERING
W/ WITH
W/O WITHOUT
W/W WALL TO WALL
WC WATER CLOSET OR WALL COVERING
WD WOOD
WDW WINDOW
WGL WIRE GLASS
WCHR WHEELCHAIR
WM WIRE MESH
WO WHERE OCCURS
WPT WORKING POINT
WR WATER RESISTANT
WSCT WAINSCOT
WSP WET STANDPIPE
WT WEIGHT
WTHPRF WEATHERPROOF
WTRPRF WATERPROOF
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
CCR CARD CONTROL READER
BUR BUILT UP ROOFING SYSTEM
CT CERAMIC TILE
BOD BASIS OF DESIGN
VIF VERIFY IN FIELD
THE FOLLOWING GENERAL NOTES APPLY TO ALL
ARCHITECTURAL SERIES SHEETS. FOR GENERAL NOTES
APPLICABLE TO ALL SHEETS REFER TO THE "PROJECT
GENERAL NOTES":
1. THE ARCHITECTURAL SERIES SHEETS ARE PART OF A
COMPLETE SET OF CONSTRUCTION DOCUMENTS
DESCRIBING THE WORK FOR THIS PROJECT. USERS OF
THESE DOCUMENTS ARE RESPONSIBLE TO REVIEW ALL
CONSTRUCTION DOCUMENTS TO UNDERSTAND AND
COORDINATE THE GRAPHIC AND ANNOTATED
INFORMATION PROVIDED IN THESE ARCHITECTURAL
SERIES SHEETS.
2. EXCEPT WHERE DIRECTED TO PLACE ITEMS OF WORK AT
THE APPROXIMATE LOCATIONS SHOWN, DO NOT SCALE
DRAWINGS FOR DIMENSIONAL INFORMATION. ALL
ELEMENTS OF THE DRAWINGS MAY NOT BE DRAWN TO
EXACT SCALE. ALL DIMENSIONS REQUIRED ARE SHOWN
OR MAY BE DERIVED FROM THOSE SHOWN ON THE FLOOR
PLANS, DETAIL PLANS, ELEVATIONS, SECTIONS, DETAILS,
SCHEDULES, AND SPECIFICATIONS.
1. THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE AND
DEFINE TYPICAL GRAPHIC SYMBOLS WHICH MAY
TYPICALLY OCCUR ON THE ARCHITECTURAL DRAWINGS.
2. ADDITIONAL SYMBOLS NOT SHOWN OR DEFINED ON THIS
SHEET MAY BE USED ON THE ARCHITECTURAL
DRAWINGS AND ARE TYPICALLY DEFINED ON OTHER
SHEETS.
3. SYMBOLS ARE NOT DRAWN TO SCALE. TO DETERMINE
THE ACTUAL SIZES OF ELEMENTS REPRESENTED BY
SYMBOLS, REFER TO THE SPECIFICATIONS AND OTHER
SHEETS, AS MAY APPLY.
1. THE TERM "REFERENCE" ELEVATION OR DIMENSIONS
REFERS TO A NOMINAL WORK POINT. THE ACTUAL
ELEVATION MAY VARY FROM THE REFERENCE POINT.
REFER TO APPLICABLE DETAIL TO DETERMINE THE
RELATIONSHIP BETWEEN THE ACTUAL ELEVATION OR
DIMENSION AND THE STATED REFERENCE POINT."
2. THE DESIGN REFERENCE ELEVATION +0'-0" SHOWN ON THE
ARCHITECTURAL DRAWINGS CORRESPONDS TO THE FINISH
FLOOR ELEVATION OF THE GROUND FLOOR. ESTABLISH
THE ACTUAL ELEVATION WITH RESPECT TO SITE-SPECIFIC
BENCHMARKS AND CONTROL POINTS AS DEFINED IN THE
CIVIL DRAWINGS.
3. "FINISH FLOOR" ELEVATIONS ARE MEASURED AT THE TOP
OF THE CONCRETE FLOOR SLAB UNLESS OTHERWISE
NOTED. APPLIED FINISHES SUCH AS RESILIENT FLOORING
OR CARPET MAY RAISE THE ACTUAL FINISH SURFACE
ABOVE THE REFERENCE ELEVATION PROVIDED FOR THE
FINISH FLOOR.
4. WHERE CONCRETE FLOOR SLAB IS DEPRESSED TO
ACCOMMODATE MORTAR BEDS, SETTING BEDS, RAISED
ACCESS FLOORS, AND OTHER SIMILAR FLOOR
ASSEMBLIES, "FINISHED FLOOR" ELEVATIONS ARE
MEASURED AS IF CONCRETE DEPRESSION DOES NOT
OCCUR.
5. CEILING HEIGHT ELEVATIONS ARE MEASURED TO BOTTOM
OF FINISH SURFACES AND STATED IN RELATION TO
DISTANCE ABOVE THE REFERENCE ELEVATION FOR THE
FINISH FLOOR UNLESS OTHERWISE NOTED.
6. ROOF ELEVATIONS ARE MEASURED TO TOP OF SURFACES
AND STATED IN RELATION TO DISTANCE ABOVE THE
REFERENCE ELEVATION PROVIDED FOR THE UPPERMOST
FINISH FLOOR UNLESS OTHERWISE NOTED. ELEVATIONS
GIVEN ARE TO TOP OF STEEL (TOS), TOP OF DECK (TOD),
OR TOP OF TAPERED INSULATION (TOT) UNLESS
OTHERWISE NOTED.
SECOND LEVEL
+10'-0"
BUILDING SECTION
WALL SECTION NUMBER
DIRECTION OF VIEW
SHEET WHERE DRAWN
WALL SECTION
WALL SECTION NUMBER
NORTH ARROW REFERENCES
TRUE NORTH
.00
0°
NEW GRID
IDENTIFICATION
EXISTING GRID
IDENTIFICATION
LAYOUT GRID LINES
BASIC DRAWING TITLE
SHEET WHERE DRAWN
DIRECTION OF VIEW
LEVEL LINE
REVISION NUMBER AND EXTENT
DETAIL REFERENCE
SECTION DETAIL REFERENCE
EXTERIOR ELEVATION
A102 2
INTERIOR ELEVATION REFERENCE
ROOM NAME AND NUMBER
ELEVATION NUMBER AND
DIRECTION
SHEET WHERE DRAWN
SHEET WHERE DRAWN
ELEVATION NUMBER AND
DIRECTION OF VIEW
SHEET WHERE DRAWN,
HYPHEN INDICATES DETAIL
ON SAME SHEET.
DETAIL NUMBER
SHEET WHERE DRAWN
ELEVATION NUMBER AND
DIRECTION
AX.X.X X
WINDOW AND LOUVER TYPE MARK
SEE CORRESPONDING
NUMBER ON SCHEDULE
SEE ASSEMBLY TYPE
FOR DETAILS.
NAME OF LEVEL
INDICATES HEIGHT
ABOVE PROJECT DATUM
REVISION NUMBER - SEE
REVISION HISTORY ON
THE TITLE BLOCK OF
EACH SHEET
EXTENT OF CURRENT
REVISION
SHEET KEYNOTE MARK
MATCH LINE REFERENCES
DRAWING TITLE SYMBOLS
A502
SEE CORRESPONDING
NUMBERED KEYNOTE ON
SHEET WHERE
REFERENCE OCCURS
REFER TO THE SHEET
WHERE CONTINUATION IS
FOUND
A B
SCALE:
A101
SIM
A101
SIM
A101
SIM
A101
SIM
MATCH LINE
W-X
View Name
1/8" = 1'-0"
REFERENCE KEYNOTE MARK
088000.A03
THE FIRST SIX DIGITS
REPRESENT THE
SPECIFICATION SECTION
EXAMPLE 1:
THE CHARACTERS
FOLLOWING THE PERIOD
REPRESENT PARTICULAR
ITEMS OF THE SPECIFIED
SYSTEM
NORTH PROJECT NORTH
OR OR
BASIC DRAWING TITLE
WITH LINESCALE:
View Name
1/8" = 1'-0"
DRAWING TITLE WHEN
ONLY ONE PLAN EXISTS
ON THE DRAWING
SCALE:
View Name 1/8" = 1'-0"
SHEET A2.1.1
SHEET A2.1.2
SHEET A2.1.1
OR
REFER TO THE SHEETS
EITHER SIDE OF THE
MATCH LINE
Room Name
M-X
061600 5/8"
PLYWOOD
EXAMPLE 2:
THE TEXT IS THE PRODUCT
DESCRIPTION
EARTH
AGGREGATE BASE COURSE
CONCRETE
CONCRETE MASONRY UNIT
BRICK MASONRY
PRECAST CONCRETE
LIMESTONE, SANDSTONE, GRANITE
MARBLE
STEEL, STAINLESS
STEEL
(LARGE SCALE)
ALUMINUM (LARGE SCALE)
OTHER METALS (LARGE
SCALE)
WOOD FRAMING -
CONTINUOUS (LARGE SCALE)
WOOD FRAMING - DISCONTINUOUS
(LARGE SCALE)
PLYWOOD
(LARGE SCALE)
FINISH WOOD (LARGE SCALE)
EIFS INSULATION BOARD
(LARGE SCALE)
SEMI-RIGID INSULATION
(LARGE SCALE)
BATT INSULATION
(LARGE SCALE)
MORTAR, SAND, FIREPROOFING,
STUCCO, GYPSUM BOARD
TERRAZZO (LARGE SCALE)
COMPOSITE BOARD
(LARGE SCALE)
ACOUSTIC TILE (LARGE SCALE)
PROTECTION BOARD
(LARGE SCALE)
CERAMIC TILE (LARGE SCALE)
GLASS (LARGE SCALE)
PLASTER CONCRETE
MASONRY, METAL SIDING
(HORIZONTAL)
GLASS BLOCK, CERAMIC TILE
METAL SIDING (VERTICAL)
GLASS
ELEVATION
PLAN AND SECTION
FOR THE ASSEMBLY TYPES LISTED, SEE THE FOLLOWING SHEETS FOR SYSTEM
DETAILS AND DESCRIPTIONS:
TYPE A = EXTERIOR WALLS - ABOVE GRADE - SHEET A5.0.X
TYPE B = EXTERIOR WALLS - VERTICAL BELOW GRADE - SHEET A5.0.X
TYPE H = FOUNDATION SLAB SYSTEMS - HORIZONTAL BELOW GRADE - SHEET A5.0.X
TYPE R = ROOFING SYSTEMS - SHEET A5.0.X
TYPE S = EXTERIOR SOFFITS - SHEET A5.0.X
TYPE X = EXTERIOR FENESTRATION SYSTEMS - SHEET A5.4.X
TYPE P = INTERIOR WALL PARTITIONS - SHEET A9.2.X
TYPE Y = INTERIOR FENESTRATION SYSTEMS - SHEET A9.3.X
TYPICAL ARCHITECTURAL ASSEMBLY IDENTIFICATION MARK
A000X
A000X
PLAN
SECTION
A000X
ASSEMBLY TYPE
ASSEMBLY NAME
REPRESENTING:
-MAJOR GROUP
-FINISH SYSTEM
-SUBSTRATE
CONFIGURATION
ASSEMBLY VARIABLE
(NOT ALWAYS PRESENT)
ASSEMBLY TAG DESIGNATION
EXISTING PARTITION TO
REMAIN
EXISTING PARTITION TO
BE REMOVED
EXISTING DOOR TO REMAIN
EXISTING DOOR AND
FRAME TO BE REMOVED
EXISTING WINDOW TO
REMAIN
EXISTING WINDOW TO
BE REMOVED
EXISTING LAY-IN
CEILING TO BE
REMOVED
EXISTING LAY-IN
CEILING TO
REMAIN
OVERHEAD ROLLING DOOR
PAIR DOORS - UNEQUAL SIZES
DOUBLE ACTING DOOR
SINGLE OPENING DOOR
2 PANEL BI-FOLD DOOR
PAIR - BI FOLD DOOR
DOOR OPENING MARK
PAIR DOORS - EQUAL SIZES
PAIR DOORS - DOUBLE EGRESS
DOOR WITH SIDE LIGHT
SLIDING DOOR - BETWEEN JAMBS
SLIDING POCKET DOOR
INTERIOR GLAZED WINDOW
1 HOUR FIRE RESISTANCE RATING
2 HOUR FIRE RESISTANCE RATING
3 HOUR FIRE RESISTANCE RATING
0 HOUR SMOKE PARTITION
4 HOUR FIRE RESISTANCE RATING
BASE CABINETS
BASE AND WALL CABINETS
WALL CABINETS
TOILET PARTITION AND DOOR
TOILET - WALL HUNG
URINAL - FLOOR/WALL HUNG
LAVATORY - COUNTERTOP
LAVATORY -
PEDESTAL/WALL HUNG
GENERAL SYMBOLS PLUMBING SYMBOLS
HANDRAIL
BUMPER GUARD
CG CG
CORNER GUARD
EDGE GUARD
OVERHEAD ITEMS
UNDER-COUNTER ITEMS
NIC NOT-IN-CONTRACT ITEMS
10' - 0"
10' - 0"
JANITOR'S RECEPTOR
DRINKING FOUNTAIN / EWC
EG
DIMENSION SYMBOLS
UTILITY SINK
BATHTUB
SHOWER
FLOOR DRAIN IN SLOPING
FLOOR
FEC
FEC
FEXT
FEC
FIRE EXTINGUISHER
BRACKET MOUNTED
FIRE EXTINGUISHER
SURFACE MOUNTED
FIRE EXTINGUISHER CABINET
SEMI-RECESSED
FIRE EXTINGUISHER CABINET
RECESSED
DIMENSION SHOWN TO:
- STRUCTURAL GRID
- LAYOUT GRID
- CENTERLINE OF ASSEMBLY
- CENTER OF OPENING
- CENTER OF EQUIP/ FURN
GRID OR CENTER LINE
TYPICAL
DIMENSION SHOWN TO:
- PARTITION ASSEMBLY
- EDGE OF DOOR OPENING
- OTHER BUILDING ELEMENT
- WORKING POINT INDICATED
ON DETAIL
FD
FIRE EXTINGUISHER SYMBOLS
DETAILS ARE NUMBERED ACCORDING TO THEIR
LOCATION ON EACH SHEET AND ARE NOT
NUMBERED CONSECUTIVELY. EACH MODULE
MAINTAINS THE NUMBER ASSOCIATED WITH IT
THIS SYSTEM CAN BE APPLIED TO ANY SHEET
THAT CONTAINS MULTIPLE IMAGES. THE IMAGES
ARE NUMBERED ACCORDING TO THE MODULE
SYSTEM SHOWN ILLUSTRATED TO THE LEFT
EACH DETAIL MAY OCCUPY ONE OR MORE
WHOLE MODULES. THE DETAIL MODULE IS USED
TO ESTABLISH THE IDENTIFYING LABEL FOR
EACH DETAIL, NOT TO LIMIT THE SIZE OF THE
DETAIL
DETAIL MODULE LAYOUT
DETAIL NUMBERING EXAMPLE
THE NUMBER OF THE MODULE WHICH
OCCURS IN THE LOWER LEFT CORNER OF A
SINGLE MODULE OR SEVERAL MODULES
GROUPED TOGETHER WILL DEFINE THE FINAL
DETAIL NUMBER AS SHOWN IN THE
ILLUSTRATION TO THE LEFT. ALTHOUGH THE
MODULE NUMBERS OCCUR IN CONSECUTIVE
ORDER, NOT ALL NUMBERS ARE
NECESSARILY USED ON EACH SHEET
163256
54 46
ARCHITECTURAL
2'X4' LAY IN ACOUSTIC
TILE CEILING
2'X2' LAY IN ACOUSTIC
TILE CEILING
GYPSUM BOARD
ACCESS PANELAP
MECHANICAL
SUPPLY GRILLE
RETURN GRILLE
EXHAUST GRILLE
LINEAR DIFFUSER
SPRINKLER HEAD - CLG MOUNT
SPRINKLER HEAD - WALL
MOUNT
ELECTRICAL
MISCELLANEOUS
2'X4' LIGHTING FIXTURE
2'X2' LIGHTING FIXTURE
1'X4' LIGHTING FIXTURE
LIGHTING STRIP FIXTURE
RECESSED DOWN LIGHT
WALL WASH
TRACK LIGHTING
EXIT SIGN, SINGLE-SIDED
EXIT SIGN, DOUBLE-SIDED
FIRE ALARM
SPEAKER
SMOKE DETECTOR
WIRELESS INTERNETW
P
S
F
HEIGHT OF CEILING FINISH
ABOVE FINISH FLOOR
+12'-8"
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
SEALS AND SIGNATURES
ISSUED FOR REV DATE
1700 NEW YORK AVENUE NW
SUITE 100
WASHINGTON, DC 20006
202.842.2100 smithgroup.com
P lo t D at e
USHMM CONFERENCE
ROOM UPGRADE
1201 Maryland Ave SW Washington, DC 20024
7/
/2
:4 5:
P
M
ARCHITECTURAL
ABBREVIATIONS AND
SYMBOLS
A001
S T
A R
T S he e t
12241
ARCHITECTURAL REFERENCE SYMBOLS ARCHITECTURAL GENERAL NOTESARCHITECTURAL FLOOR PLAN SYMBOLSARCHITECTURAL ABBREVIATIONS
ARCH REFLECTED CEILING PLAN SYMBOLS
DOOR AND INTERIOR OPENING SYMBOLS
ARCHITECTURAL MATERIAL INDICATIONS
MODULAR LAYOUT / DETAIL NUMBER
REFERENCE ELEVATION DEFINITIONS
FIRE RESISTIVE RATING
INDICATION
ARCHITECTURAL DEMOLITION SYMBOLS
ARCHITECTURAL SYMBOL
NOTES
ARCHITECTURAL ASSEMBLY SYSTEM TAGS
100% / PERMIT SET 07.21.2023
sghorbanian Image
A. IT IS THE INTENT OF THE DESIGN THAT ALL ITEMS SHOWN
MOUNTED AT TYPICAL HEIGHTS BE ACCESSIBLE TO
PERSONS WITH DISABILITIES.
B. THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE TYPICAL
MOUNTING HEIGHTS AND - WHERE APPLICABLE - TYPICAL
MINIMUM OR MAXIMUM CLEARANCES AND/OR TYPICAL
MOUNTING CONFIGURATIONS FOR A VARIETY OF ITEMS.
CAUTION: THIS SHEET MAY ILLUSTRATE ITEMS OR
CONFIGURATIONS WHICH DO NOT OCCUR AS PART OF THE
WORK OF THIS PROJECT. REFER TO THE PLANS,
ELEVATIONS, SECTIONS, DETAILS, AND SCHEDULES TO
DETERMINE WHICH ITEMS AND CONFIGURATIONS APPLY TO
THE WORK OF THIS PROJECT.
C. NOT ALL PROJECT ITEMS MAY BE REPRESENTED ON THIS
SHEET. FOR ITEMS WITH OPERABLE PARTS NOT SHOWN ON
THIS SHEET, THE ITEM SHALL BE MOUNTED SUCH THAT THE
OPERABLE PART IS A MAXIMUM OF 42" ABOVE FINISH FLOOR
UNLESS SPECIFICALLY NOTED OR DIMENSIONED
OTHERWISE.
D. THE MOUNTING HEIGHTS, CLEARANCES, AND
CONFIGURATIONS SHOWN ON THIS SHEET ARE TYPICAL AND
SHALL APPLY TO ALL INSTANCES OF THE ITEM (OR GROUP
OF ITEMS) SHOWN UNLESS SPECIFICALLY NOTED OR
DIMENSIONED OTHERWISE.
E. SPECIAL OR NON-TYPICAL MOUNTING HEIGHTS OCCUR
ONLY WHERE INDICATED BY ANNOTATED SYMBOLS; BY KEY
NOTES; BY NOTES ON PLANS, ELEVATIONS, OR DETAILS; OR
BY UNIQUE DIMENSIONS ON ELEVATIONS OR DETAILS.
F. FOR ADDITIONAL INFORMATION REGARDING THE
PRECEDENCE OF DRAWINGS FOR DETERMINING THE EXACT
LOCATION OF EACH EXPOSED PART OF THE WORK, REFER
TO THE "ARCHITECTURAL GENERAL NOTES" AND TO THE
"TYPICAL RULES FOR DETERMINING MOUNTING HEIGHTS
AND LOCATIONS" LOCATED PER THE INDEX OF DRAWINGS IN
THIS SET.
G. TYPICAL MOUNTING HEIGHTS MAY BE ILLUSTRATED BY
OTHER DRAWING SERIES, SUCH AS Q SERIES. REFER TO
THE 'INDEX OF DRAWINGS' FOR ADDITIONAL INFORMATION.
H. MOUNTING CONFIGURATION DIAGRAMS ARE ELEVATIONS
WHICH ILLUSTRATE TYPICAL RULES GOVERNING THE
RELATIONSHIPS BETWEEN, AND PLACEMENT OF, ITEMS
WHICH OCCUR IN GROUPS OF RELATED ITEMS OR IN CLOSE
PROXIMITY TO OTHER PARTS OF THE WORK (SUCH AS
SWITCHES AND DOOR FRAMES). UNLESS OTHER MOUNTING
CONFIGURATIONS ARE SPECIFICALLY NOTED,
DIMENSIONED, OR ELEVATED, THE TYPICAL RELATIONSHIPS,
ARRANGEMENTS, AND THE TYPICAL CONFIGURATION
DIAGRAMS APPLY THROUGHOUT THE WORK OF THIS
PROJECT.
J. TYPICAL MOUNTING CONFIGURATIONS FOR ADDITIONAL
GROUPING NOT SHOWN ON THIS MAY BE SHOWN ON OTHER
SHEETS. REFER TO THE "INDEX OF DRAWINGS" FOR
ADDITIONAL INFORMATION.
K. A TACTILE EXIT SIGN STATING "EXIT" AND COMPLYING WITH
ICC A117.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR
TO AN AREA OF REFUGE, AN EXIT STAIRWAY, AN EXIT RAMP,
AN EXTERIOR AREA FOR ASSISTED RESCUE, AN EXIT
PASSAGEWAY AND THE EXIT DISCHARGE.
L. REFER TO RULE 16 ON A0.4 FOR ITEM MOUNTING HEIGHTS
IN MASONRY PARTITIONS.
T O
U N
O B
S T
R U
C T
E D
C O
N T
R O
LS
4'
M
A X
H
IG
H R
E A
C H
3'
A T
M A
S O
N R
Y W
A
LL
S 3'
T
Y P
T O
C L
C O
N T
R O
LS
R E
A C
H
1'
M
IN
LO
W
M A
S O
N R
Y W
A
LL
S
1'
T Y
P 1'
A
T
COUNTER TOP
OR BACKSPLASH
WHERE OCCURS
T O
O B
S T
R U
C T
E D
C O
N T
R O
LS
3'
M
A X
H
IG
H R
E A
C H
5" M
IN
F
O R
V E
R T
3"
M
IN
F O
R
H
R
IZ
, R E
F E
R T
IN
T
E R
IO
E
LE
V
A T
IO
N
S F
D
V
IC
E
H E
IG
H
T
R E
F E
R T
O E
LE
C
F
R
D E
V
IC
IE
N
T A
T
IO
N
CARD READER,
LOCAL ALARM,
OR ARMING
STATION
NURSE CALL
STATION
WITH
CONTROLS
WALL-MTD
TELEPHONE
OUTLET
SPECIAL
PURPOSE
OUTLETS
SPECIAL
PURPOSE
OUTLETS OR
JUNCTION BOX
THERMOSTATPHONE/DATA
OUTLET
INTERCOM
STATION
DESK
INTERCOM
OUTLET
DUPLEX
OUTLET
DUPLEX
OUTLET
ABOVE COUNTER OR
BACKSPLASH WHERE OCCURS
MANUAL FIRE
ALARM PULL
STATION
RACEWAYFIREMAN'S
TELEPHONE
JACK
LIGHT SWITCH
& DIMMER
CLOCK OR
CLOCK OUTLET
DARK ROOM
STATUS LIGHT
SWITCH AT
DOOR OR
CASED OPENING
7'
A F
F
A
LI
G N
W
IT
H T
O P
O F
A D
JA
C
E N
T F
R A
M E
TYP
8"
8" TYP
6" B
E
LO
W C
E
IL
IN
G
W H
IC
H
E V
E R
IS
L
O W
E R
7'
A F
F T
O C
L O
R
6" B
E
LO
W C
E
IL
IN
G
W H
IC
H
E V
E R
IS
L
O W
E R
7'
A F
F T
O C
L O
R
6" B
E
LO
W C
E
IL
IN
G
W H
IC
H
E V
E R
IS
L
O W
E R
7'
A F
F T
O C
L O
R
NURSE
CALL
STATION
WITHOUT
CONTROLS
5'
NURSE CALL
CORRIDOR
LIGHT (DOME
LIGHT)
7'
EMERGENCY
STROBE OR
LIGHT
SECURITY
STROBE LIGHT
(BLUE LIGHT)
AUDIBLE
AND/OR VISUAL
FIRE ALARM
REQD SIGNAGE
AT MEN'S TOILET
ENTRY DOOR
REQD SIGNAGE AT
WOMEN'S TOILET
ENTRY DOOR
REQD SIGNAGE AT
UNISEX TOILET
ENTRY DOOR
MEDICAL
GAS ALARM
PANEL
EQ EQ 1' - 0"
4'
/4
5'
EQ EQ 1' - 0"
5'
EQ EQ 1' - 0"
5'
1' - 0"
4'
1'
T O
U N
O B
S T
R U
C T
E D
C O
N T
R O
LS
4'
M
A X
H
IG
H R
E A
C H
3'
A T
M A
S O
N R
Y W
A
LL
S 3'
T
Y P
T O
C L
C O
N T
R O
LS
R E
A C
H
1'
M
IN
LO
W
T O
O B
S T
R U
C T
E D
C O
N T
R O
LS
3'
M
A X
H
IG
H R
E A
C H
COAT
HOOKS
(WALL-MTD)
COAT
HOOK
(DOOR-MTD)
CHALKBOARD,
TACKBOARD, OR DRY
MARKER BOARD
LOW LEVEL EXIT SIGN
(WHERE OCCURS) AT
EXIT DOOR
TACTILE
EXIT SIGN -
REFER TO
TO NOTE "L"
CEILING LINE
EXIT
EXIT
EXIT
6"
5'
3'
EQ EQ
6'
7'
6"
4"
TACTILE
EXIT SIGN -
REFER TO
TO NOTE "L"
4" EQ EQ
2"
1'
O R
G R
E A
T E
R
M O
U N
T O
N S
T R
IK
E
S
ID
E
A
LI
G N
W
IT
H T
O P
O F
A D
JA
C
E N
T F
R A
M E
W H
E N
D
IM
A B
O V
E D
O O
R H
E A
D
2"
IS
2" O
R G
R E
A T
E R
LO
C
A T
E
A
B O
V E
D O
O R
F R
A M
E W
H E
N D
IM
A
B O
V E
D O
O R
H E
A D
FEC OR
FHV
CABINET
ELECTRICAL
PANELBOARD
(FLUSH MTD)
ELECTRICAL
PANELBOARD
(SURFACE MTD)
6'
6'
2'
M A
X
WALL-MOUNTED
EXIT SIGN AT
EXIT DOOR
- CONTINUED AT TOP OF NEXT COLUMN
D.
5.
DIMENSION, WHEN OCCURS
ALIGN
B.
C.
B.
A.
4.
3.
A.
F.
E.
D.
1.
2.
E.
NOTE NO 4 CONTINUED:4.
C.
EXCEPT WHERE DIRECTED TO PLACE ITEMS OF THE
WORK AT THE "APPROXIMATE LOCATION SHOWN,"
DO NOT SCALE DRAWINGS FOR DIMENSIONAL
INFORMATION.
ALL ELEMENTS OF THE DRAWINGS MAY NOT BE
DRAWN TO EXACT SCALE. ALL DIMENSIONS
REQUIRED ARE SHOWN (OR MAY BE DERIVED
FROM THOSE SHOWN OR NOTED) ON THE FLOOR
PLANS, DETAIL PLANS, ELEVATIONS, SECTIONS,
SCHEDULES, CONFIGURATION DETAILS, AND
SPECIFICATIONS. SEE THE NOTES BELOW AND
SYMBOLS ON SHEET A001 FOR DIMENSIONING
CONVENTIONS USED ON THIS PROJECT.
EXCEPT WHERE SPECIFICALLY NOTED TO THE
CONTRARY, ALL DIMENSIONS SHOWN ON THE
ARCHITECTURAL DRAWINGS CONFORM TO THE
FOLLOWING CONVENTIONS:
DIMENSIONS UTILIZING THE "CENTERLINE" SYMBOL
ARE MEASURED TO:
STRUCTURAL OR DIMENSIONAL GRID LINES.
CENTERLINE OF CONCRETE OR CONC
MASONRY UNIT WALLS (EXCLUSIVE OF
FURRING OR APPLIED FINISHES HAVING
THICKNESS). REFER TO THE ARCH PLANS
AND SECTIONS, THE STRUCT DRAWINGS,
OR PARTITION SCHEDULE TO DETERMINE
THE THICKNESS OF CONCRETE OR CONC
MASONRY UNIT WALLS.
CENTERLINE OF PARTITION ASSEMBLY
(EXCLUSIVE OF ANY APPLIED FINISHES
HAVING THICKNESS WHICH MAY BE
ADDED TO SUCH WALLS) AT PARTITIONS
FRAMED WITH METAL STUDS. REFER TO
"PARTITION SCHEDULE" TO DETERMINE
THICKNESS OF EACH PARTITION TYPE.
CENTERLINE OF DOOR, WINDOW, OR LOUVER
OPENING.
CENTERLINE OF EQUIPMENT OR
FURNISHING.
CENTERLINE OF OTHER FEATURES AS
INDICATED.
REFER TO SHEET A001 FOR SYMBOL USED
TO INDICATE CENTERLINE DIMENSION.
DIMENSIONS UTILIZING THE "FACE OF"
SYMBOL ARE MEASURED TO:
FACE OF CONCRETE OR CONC MASONRY
UNIT WALL (EXCLUSIVE OF APPLIED
FINISHES HAVING THICKNESS OR FURRING
WHICH MAY BE ADDED TO THE FACE OF
SUCH WALLS).
FACE OF PARTITION ASSEMBLY
(EXCLUSIVE OF ANY APPLIED FINISHES
HAVING THICKNESS WHICH MAY BE
ADDED TO SUCH WALL) AS DEFINED
BY THE PARTITION SCHEDULE.
UNLESS NOTED AS A "FACE OF
FINISH" OR "CLEAR" DIMENSION (SEE
NOTE 'E' BELOW), DIMENSIONS ARE
NOT MEASURED TO THE FACE OF
APPLIED FINISH. REFER TO THE
"PARTITION SCHEDULE" TO DETERMINE
THE THICKNESS OF EACH PARTITION
TYPE.
INSIDE EDGE OF FINISHED DOOR
OPENING. REFER TO THE "DOOR
SCHEDULE" FOR ADDITIONAL
DIMENSIONAL INFORMATION.
DIMENSION OR WORK POINT AS
INDICATED ON RELATED ARCH DETAIL
PLAN, SECTION, ELEVATION, LAYOUT
OR CONFIGURATION DETAIL, OR
CONSTRUCTION DETAIL.
REFER TO SHEET A001 FOR SYMBOL USED
TO INDICATE "FACE OF" DIMENSION.
WHERE "FACE OF FINISH" OR "CLEAR" DIMENSIONS
ARE SPECIFICALLY NOTED, THE DIM IS MEASURED
TO:
FINISH FACES AT THE MOST NARROW
OR CONSTRICTED POINTS OF SECTION
WHERE DIMENSION IS SHOWN, WHEN
THE DIMENSION OCCURS ACROSS AN
OPEN SPACE. THIS CASE, A "FACE
OF FINISH" DIMENSION IS EQUIVALENT
TO A "CLEAR" DIMENSION.
FINISH FACES AT THE WIDEST OR MOST
EXPANSIVE POINTS OF THE SECTION THE
DIMENSION IS SHOWN WHEN THE DIMENSION
OCCURS ACROSS AN OBJECT OR GROUP OF
OBJECTS.
WHERE "EQUAL" DIMENSIONS ARE USED
ON REFLECTED CEILING PLANS TO
LOCATE CEILING GRID WORK POINTS,
MEASURE DIMENSIONS TO:
EDGE OF THE INDICATED CEILING AT
THE FACE OF THE ADJACENT APPLIED
FINISH MEASURED AT THE PLANE OF
THE CEILING.
CAUTION: DUE TO THE POSSIBLE
APPLICATION OF APPLIED FINISHES -
THICKNESS OF WHICH MAY VARY
BETWEEN FLOOR AND CEILING AND IS
NOT ACCOUNTED FOR (EXCEPT AS
INDICATED BY "FOF" OR "CLEAR") BY
THE DIMENSION SHOWN ON THE FLOOR
PLANS - THE CONTRACTOR MUST
ADJUST, AS NECESSARY, THE FLOOR
PLAN DIMENSIONS TO REFLECT THE
ACTUAL DIMENSIONS FOUND AT PLANE
OF THE CEILING.
WHERE DIMENSIONS ARE NOT PROVIDED ON
FLOOR PLANS TO LOCATE DOOR OPENINGS,
APPLY THE FOLLOWING RULES, IN ORDER, TO
DETERMINE THE LOCATION OF DOOR OPENINGS:
DOOR OPENINGS MAY BE
DIMENSIONED ON DRAWINGS OTHER
THAN THE FLOOR PLANS. REFER TO
THE SECTIONS, ELEVATIONS, DETAILS,
AND DOOR SCHEDULE NOTES FOR
ADDITIONAL DIMENSIONAL
INFORMATION.
WHERE THE HINGE-SIDE OF A DOOR IS
SHOWN ADJACENT TO A WALL - OR WALLS
- PERPENDICULAR TO THE WALL IN WHICH
THE DOOR OPENING OCCURS:
AT DOORS OCCURRING IN METAL FRAMED
GYPSUM BOARD PARTITIONS, LOCATE THE
HINGE-SIDE OF THE DOOR FINISHED
OPENING 4 INCHES FROM THE FACE
(EXCLUSIVE OF APPLIED FINISHES) OF THE
THE CLOSEST PERPENDICULAR WALL OR
PARTITION ASSEMBLY.
AT DOORS OCCURRING IN WALLS OF CONC
MASONRY UNIT CONSTRUCTION, LOCATE
THE HINGE-SIDE OF THE DOOR FINISHED
OPENING 10 INCHES FROM THE FACE
(EXCLUSIVE OF APPLIED FINISHES) OF THE
THE CLOSEST PERPENDICULAR WALL OR
PARTITION ASSEMBLY.
WHERE DOOR OCCURS NOT ADJACENT TO A
PERPENDICULAR WALL AND EITHER "DIM E"
OR "DIM F" IS 16'-0" OR LESS, LOCATE
DOOR UTILIZING THE FOLLOWING MINIMUM
DIMENSIONS:
DIMENSION A = 18 INCHES MIN
DIMENSION B = 12 INCHES MIN
DIMENSION C = DOOR WIDTH + 2
INCHES MINIMUM
DIMENSION D = 4 INCHES MIN AT
METAL FRAMED GYP BD PARTITIONS
OR - EVEN MULTIPLE OF 1/2 CMU
MODULE PLUS 2 INCHES AT CONC
MASONRY UNIT WALLS
DIMENSIONS E AND F = AS SHOWN ON
PLANS
DIMENSION G = 36 INCHES MIN
DIMENSION H = 60 INCHES MIN
IF SPACE ALLOWS, CENTER DOOR IN
WALL SHOWN ON THE DRAWINGS SO
THAT EITHER "DIM A" EQUALS "DIM C"
OR "DIM B" EQUALS "DIM D".
IF "DIM E" IN DIAGRAMS BELOW IS LESS
THAN THE SUM OF 2 TIMES THE DOOR
WIDTH PLUS 20 INCHES, LOCATE DOOR
SO THAT MINIMUMS STATED BY NOTE
NO 4C ABOVE FOR "DIM A", "DIM B,"
AND "DIM D" ARE MET - MAXIMIZING
"DIM A" AND MINIMIZING "DIM D" TO
THE EXTENT POSSIBLE.
WHERE DOOR IS SHOWN LOCATED IN A
LARGE EXPANSE OF OPEN WALL ("DIM
E" AND "DIM F" IN DIAGRAM BELOW
BOTH EXCEED 16'-0"), PLACE DOOR
AT APPROXIMATE LOCATION SHOWN ON
THE PLANS. WHERE DOOR OCCURS IN
CMU WALL, PLACE DOOR AT
APPROXIMATE LOCATION SHOWN WHILE
MINIMIZING "CUT" OR PARTIAL CMU
MODULES ADJACENT TO THE JAMBS.
WHERE WALLS AND/OR PARTITIONS OF
UNEQUAL THICKNESS ABUT, ALIGN EXPOSED
FACES, UNLESS OTHERWISE NOTED.
3. NOTE NO 3 CONTINUED:
MEASURED AT CLG PLANE
"EQUAL" DIM AT CEILING
MEASURED TO FACE OF PTN
TYPICAL DIM ON CEILING PLAN
4"
4"
10"
10"
DIM E > 16'-0"
DIM F > 16'-0"
E
A
E
A D
B D B
E
A C
F
B D
G
H
- CONTINUED AT TOP OF NEXT COLUMN
3. NOTE NO 3 CONTINUED: NOTE NO 4 CONTINUED:4.
- CONTINUED AT TOP OF NEXT COLUMN
- CONTINUED AT TOP OF NEXT COLUMN
SHEET NUMBER
PROJECT NUMBER
SHEET TITLE
SEALS AND SIGNATURES
ISSUED FOR REV DATE
1700 NEW YORK AVENUE NW
SUITE 100
WASHINGTON, DC 20006
202.842.2100 smithgroup.com
P lo t D at e
USHMM CONFERENCE
ROOM UPGRADE
1201 Maryland Ave SW Washington, DC 20024
7/
/2
:4 5:
P
M
TYPICAL MOUNTING
HEIGHTS AND
DIMENSIONING
CONVENTIONS
A002
S T
A R
T S he e t
12241
GENERAL MOUNTING
HEIGHT NOTES
TYPICAL MOUNTING HEIGHTS AND CLEARANCES
ARCHITECTURAL DIMENSIONING CONVENTIONS
GENERAL MOUNTING
HEIGHT NOTES
TYPICAL MOUNTING HEIGHTS AND CLEARANCES
ARCHITECTURAL DIMENSIONING CONVENTIONS
100% / PERMIT SET 07.21.2023
GRID
GRID
GRID
GRIDGRID
GRID
GRID
GRIDGRID
GRID
LOCATE ITEMS AS INDICATED WHEN SHOWN DIMENSIONED
(BOTH HORIZ AND VERT) BY AN ELEVATION, SECTIONAL
ELEVATION, OR DETAIL ELEVATION.
SPECIFIC DIMENSIONS SHOWN BY ELEVATIONS, SECTIONAL
ELEVATIONS, OR DETAIL ELEVATIONS TAKE PRECEDENCE
OVER TYPICAL MOUNTING HEIGHTS AND LOCATION RULES.
SPECIFIC MOUNTING DIMENSIONS SHOWN BY ELEVATIONS,
SECTIONAL ELEVATIONS, OR DETAIL ELEVATIONS TAKE
PRECEDENCE OVER CONFLICTING DIMENSIONS, IF ANY,
SHOWN ON PLANS OR DETAIL PLANS.
WHEN COMPLETELY DIMENSIONED IN ELEVATION
RULE 1
LOCATE ITEMS AS INDICATED WHEN SHOWN DIMENSIONED
(VERTICAL) BY AN ELEVATION, SECTIONAL ELEVATION, OR DETAIL
ELEVATION AND DIMENSIONED (HORIZONTAL) BY A PLAN OR
DETAIL PLAN.
SPECIFIC VERTICAL DIMENSIONS SHOWN BY ELEVATIONS,
SECTIONAL ELEVATIONS, OR DETAIL ELEVATIONS AND SPECIFIC
HORIZONTAL DIMENSION SHOWN BY PLANS AND DETAIL PLANS TAKE
PRECEDENCE OVER TYPICAL MOUNTING HEIGHTS AND LOCATION
RULES.
WHEN COMPLETELY DIMENSIONED BY COMBINATION OF PLAN AND ELEVATION
RULE 2
WHEN COMPLETELY DIMENSIONED ON PLANS
RULE 3
LOCATE ITEMS AS INDICATED WHEN SHOWN DIMENSIONED
(BOTH HORIZONTAL AND VERTICAL) BY A PLAN OR DETAIL
PLAN.
SPECIFIC VERTICAL DIMENSIONS SHOWN BY ELEVATIONS,
SECTIONAL ELEVATIONS, OR DETAIL ELEVATIONS AND SPECIFIC
HORIZONTAL DIMENSIONS SHOWN BY PLANS AND DETAIL PLANS
TAKE PRECEDENCE OVER TYPICAL MOUNTING HEIGHTS AND
LOCATION RULES.
NON-TYPICAL MOUNTING HEIGHTS MAY BE INDICATED BY
SYMBOL (AS SHOWN), BY KEYED NOTE, OR BY NOTATION ON
PLANS.
10'-6"C
C
C
WHEN DIMENSIONED HORIZONTALLY IN PLAN OR ELEVATION, BUT NOT DIMENSIONED VERTICALLY
RULE 4
LOCATE ITEMS AT TYPICAL MOUNTING HEIGHT WHEN NO VERTICAL
DIMENSION IS PROVIDED. LOCATE ITEMS AS INDICATED WHEN
HORIZONTAL DIMENSION IS PROVIDED BY ELEVATION, SECTIONAL
ELEVATION, DETAIL ELEVATION, PLAN, OR DETAIL PLAN.
SPECIFIC HORIZONTAL DIMENSIONS SHOWN BY ELEVATIONS, SECTIONAL
ELEVATIONS, DETAIL ELEVATIONS, PLANS, OR DETAIL PLANS TAKE
PRECEDENCE OVER TYPICAL MOUNTING LOCATION RULES.
WHEN NO DIMENSIONS ARE PROVIDED IN PLANS OR ELEVATIONS
RULE 5
UTILIZE TYPICAL MOUNTING CONFIGURATION DIAGRAMS PROVIDED
TO DETERMINE HORIZONTAL AND VERTICAL LOCATION OF ITEM OR
GROUP OF ITEMS IN RELATION TO OTHER, DIMENSIONED ITEMS.
SPECIFIC DIMENSIONS SHOWN BY TYPICAL MOUNTING
CONFIGURATION DIAGRAMS TAKE PRECEDENCE OVER
CONFIGURATIONS SHOWN WITHOUT DIMENSIONS ON ELEVATIONS.
SEE APPLICABLE TYPICAL CONFIGURATION DIAGRAM
IN EXAMPLE SHOWN, NURSE CALL LIGHT IS TYPICALLY LOCATED IN
RELATION TO TOP AND SIDE OF DOOR FRAME. THE DOOR LOCATION
MAY BE DETERMINED FROM DIMENSIONS SHOWN ON THE PLANS OR
THE PROJECT DIMENSIONING CONVENTIONS. THE DOOR AND FRAME
DIMENSIONS MAY BE DETERMINED FROM THE DOOR SCHEDULE.
C
NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER
RULE 6
WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR
PILASTER, AND WHEN NO OTHER TYPICAL CONFIGURATION
DIAGRAM APPLIES: HORIZONTALLY CENTER ITEM ON FACE OF
COLUMN OR PILASTER. ALIGN VERTICALLY CENTERS OF MULTIPLE
ITEMS HAVING DIFFERING TYPICAL MOUNTING HEIGHTS.
WHEN MULTIPLE ITEMS HAVING THE SAME TYP MOUNTING HEIGHT
ARE INDICATED, HORIZONTALLY CENTER GROUP OF ITEMS ON
FACE OF COLUMN OR PILASTER (SEE RULE 7).
ON PLANS, ITEMS TO BE
VERTICALLY ALIGNED MAY
BE SHOWN ADJACENT.
WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR
PILASTER, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM
APPLIES: HORIZONTALLY CENTER GROUP OF SIMILAR ITEMS HAVING THE
SAME MOUNTING HEIGHT(S) ABOUT THE CENTERLINE OF THE COLUMN OR
PILASTER.
WHEN APPLICABLE, COMBINE THIS RULE WITH RULE 6 TO
SYMMETRICALLY ARRANGE GROUPS OF ITEMS HAVING BOTH DIFFERING
AND SIMILAR MOUNTING HEIGHTS.
ARRANGE ITEMS AT SAME HEIGHT
SYMMETRICALLY ABOUT
CENTERLINE
NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER
RULE 7
WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR
PILASTER, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM
APPLIES: HORIZONTALLY CENTER GROUP OF DISSIMILAR ITEMS HAVING
CONFLICTING MOUNTING HEIGHT(S) ABOUT THE CENTERLINE OF THE
COLUMN OR PILASTER.
WHEN APPLICABLE, COMBINE THIS RULE WITH RULE 6 AND/OR
RULE 7 TO SYMMETRICALLY ARRANGE GROUPS OF ITEMS HAVING
DIFFERING, SIMILAR, AND CONFLICTING MOUNTING HEIGHTS.
ARRANGE ITEMS AT CONFLICTING
HEIGHTS SYMMETRICALLY ABOUT
CENTERLINE
NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER
RULE 8
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO
STRIKE SIDE OF DOOR, AND WHEN STRIKE-SIDE CLEARANCE IS
BETWEEN 12 INCHES AND 18 INCHES, AND WHEN NO OTHER TYPICAL
CONFIGURATION DIAGRAM APPLIES: MOUNT ITEMS IN RELATION TO
FRAME USING TYPICAL OFFSET DIMENSION. VERTICALLY ALIGN
CENTERS OF ITEMS MOUNTED AT DIFFERENT HEIGHTS.
STRIKE SIDE OF DOOR
LINE OF WALL OR OTHER RESTRICTION
ON STRIKE-SIDE OF DOOR
WHEN MULTIPLE ITEMS HAVING THE SAME TYPICAL
MOUNTING HEIGHT ARE INDICATED, MOUNT FIRST ITEM IN
RELATION TO FRAME USING TYPICAL OFFSET DIMENSION
AND PLACE REMAINING ADJACENT TO FIRST ON SIDE
OPPOSITE FRAME AS ILLUSTRATED BY THIS DIAGRAM. DO
NOT CROWD MULTIPLE ITEMS AGAINST WALL OR
RESTRICTION.
NOT DIMENSIONED AND LOCATED ADJACENT TO MINIMUM STRIKE-SIDE OF DOOR
RULE 9
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO
DOOR, AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM
APPLIES: MOUNT ITEMS IN RELATION TO FRAME USING TYPICAL
OFFSET DIMENSION. VERTICALLY ALIGN CENTERS OF ITEMS
MOUNTED AT DIFFERENT HEIGHTS.
WHEN MULTIPLE ITEMS HAVING THE SAME TYPICAL MOUNTING
HEIGHT ARE INDICATED, MOUNT FIRST ITEM IN RELATION TO
FRAME USING TYPICAL OFFSET DIMENSION AND PLACE REMAINING
ITEMS ADJACENT TO FIRST ON SIDE OPPOSITE FRAME AS
ILLUSTRATED BY THIS DIAGRAM.
MULTIPLE ITEMS AT SAME
HEIGHT
WHEN PROVIDED, UTILIZE TYPICAL
MOUNTING DIAGRAMS TO DETERMINE
DIMENSIONS
SIMILAR RULE APPLIES WHEN ADJACENT TO WINDOW.
FOR PURPOSES OF THESE RULES, ITEMS SHOWN
LOCATED APPROXIMATELY WITHIN 4 FEET OF DOOR ARE
CONSIDERED TO BE ADJACENT TO DOOR (OR WINDOW).
WHERE MULTIPLE DISSIMILAR ITEMS HAVING
CONFLICTING MOUNTING HEIGHTS OCCUR, RULE 13 ALSO
APPLIES.
NOT DIMENSIONED AND LOCATED ADJACENT TO DOOR OR WINDOW
RULE 10
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO DOOR,
AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM APPLIES:
MOUNT ITEMS IN RELATION TO SWING USING TYP OFFSET DIMENSION.
VERTICALLY ALIGN CENTERS OF ITEMS MOUNTED AT DIFFERENT
HEIGHTS.
WHEN MULTIPLE ITEMS…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .