Exhibit I Security Unit Price List.pdf

PDF 144 KB Posted

Attached to
OFFICE SPACE FOR US ARMY COE NASHVILLE TN
Solicitation number
W912QR-110EKFBNASHVILLETN
Issued by

About this file

This document is a Security Unit Price List (FSL II) template used to establish pricing for Building Specific Amortized Capital (BSAC) security countermeasures in federal real property leases. The form is completed post-award and requires lessors to provide unit prices and quantities for security improvements identified in the lease's Design Intent Drawings and Construction Documents.

The pricing template covers seven primary security categories: (1) Facility Entrances, Lobby, Common Areas, Non-Public, and Utility Areas, including employee access control, screening requirements, public restroom access, critical area securing, and visitor access control; (2) Interior Government Space requirements for identity verification and key control programs; (3) Sites and Exterior of Building improvements such as signage, landscaping, hazmat storage, receptacle placement, and parking access restrictions; (4) Security Systems including system testing and maintenance, video surveillance systems, intrusion detection, duress alarms, and security systems design; (5) Structure modifications for window locks and secure air intake grilles; (6) Operations and Administration elements; and (7) Cybersecurity requirements. The form notes that certain items marked "Government Provided" indicate the government will supply scope, product, and installation. Unit costs are subject to further negotiation prior to issuance of a Notice To Proceed, and lease-specified overhead fees on the BSAC total amount should be calculated on a separate TICS form. The document includes instructions for leasing specialists to adjust the spreadsheet if security paragraphs are added or deleted from the lease.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Lease Security Standards Section Unit Price Quantity Total

I.

FACILITY ENTRANCES, LOBBY, COMMON AREAS, NON-

PUBLIC, AND UTILITY AREAS

A. FACILITY ENTRANCES AND LOBBY

1. EMPLOYEE ACCESS CONTROL AT ENTRANCES

B. SCREENING REQUIREMENTS

1. ACCOMODATION OF RETAIL/MIXED USE SPACE

C. COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS

1. PUBLIC RESTROOM ACCESS

2. SECURING CRITICAL AREAS

3. VISITOR ACCESS CONTROL

4.

PUBLIC SPACE RESTRICTIONS WITH PRIMARY VERTICAL LOAD

MEMBERS

4a.

RESTRICT CONTACT FROM PUBLIC AREAS WITH PRIMARY VERTICAL

LOAD MEMBERS

4b.

RESTRICT CONTACT FROM MAIL AREAS WITH PRIMARY VERTICAL

LOAD MEMBERS

II. INTERIOR (GOVERNMENT SPACE)

A. IDENTITY VERIFICATION

B FORMAL KEY CONTROL PROGRAM

III. SITES AND EXTERIOR OF THE BUILDING

A. SIGNAGE

1. POSTING OF SIGNAGE IDENTIFYING THE SPACE AS GOVERNMENTAL

2. POSTING OF REGULATORY SIGNAGE

B. LANDSCAPING AND ENTRANCES

1. LANDSCAPING REQUIREMENTS

2. HAZMAT STORAGE

The Building Specific Amortized Capital (BSAC) amount under the Lease represents an estimate of the possible countermeasures outlined under the Security

Requirements section of the lease. The actual BSAC amount shall be determined after the final design. Using this form, the Lessor shall quote unit prices on all security countermeasures identified in the Lease, as reflected in the final Design Intent Drawings (DIDs) and Construction Documents (CDs). These unit costs shall be subject to further negotiation, prior to issuance of a 'Notice To Proceed' for the security improvements. Refer to 'Security Standards' attachment to the Lease for additional details.

Input 'Unit Price' and 'Quantity' figures for BSAC items (light blue) and the total will automatically be calculated for that row.SHELL and TI costs should be included on a

'TICS' form if one has been provided by the Government. Lease-specified overhead fees on the BSAC amount can likewise be calculated on the TICS form by transferring the BSAC 'Total Costs' calculated at the bottom of this worksheet to the TICS form according to the instructions on that document.

LEASE NUMBER [INSERT LEASE #]

[INSERT CLIENT NAME]

[INSERT CITY and STATE]

To be filled out post-award

SECURITY UNIT PRICE LIST (FSL II)

[INSERT DATE]

INSTRUCTIONS TO THE LEASING SPECIALISTS: THIS SPREADSHEET REFLECTS THE BASELINE SET OF SECURITY

PARAGRAPHS. EACH PARAGRAPH IN THE SECURITY SECTION WILL HAVE A CORRESPONDING LINE. IF THE SECURITY

SECTION IS ADJUSTED BY ADDING OR DELETING PARAGRAPHS THE SPREADSHEET MUST BE CHANGED ACCORDINGLY.

Security Unit Price List (Level II)

REV (OCT 2024)

3. PLACEMENT OF RECEPTACLES, CONTAINERS, AND MAILBOXES

C. PARKING

1. PUBLIC ACCESS TO GOVERNMENT PARKING AREAS

IV. SECURITY SYSTEMS

A. SECURITY SYSTEM TESTING & MAINTENANCE CRITERIA -$

B. VIDEO SURVEILLANCE SYSTEM (VSS)

LESSOR PROVIDED DESIGN AND INSTALLATION -$

GOVERNMENT PROVIDED SCOPE, PRODUCT, AND INSTALLATION Government Provided

C. INTRUSION DETECTION SYSTEM

LESSOR PROVIDED DESIGN AND INSTALLATION -$

GOVERNMENT PROVIDED SCOPE, PRODUCT, AND INSTALLATION Government Provided

D. DURESS ALARM

LESSOR PROVIDED DESIGN AND INSTALLATION -$

GOVERNMENT PROVIDED SCOPE, PRODUCT, AND INSTALLATION Government Provided

E. SECURITY SYSTEMS DESIGN -$

V. STRUCTURE

A. WINDOWS

LOCK GROUND FLOOR WINDOWS (BSAC- IDS Monitoring) -$

B. BUILDING SYSTEMS

1. EMERGENCY GENERATOR PROTECTION (T.I.)

2. SECURE AIR INTAKE GRILLES -$

VI. OPERATIONS AND ADMINISTRATION

A. FACILITY SECURITY COMMITTEE (FSC) -

B. ACCESS TO BUILDING INFORMATION

C. CONSTRUCTION SECURITY PLAN

VII. CYBERSECURITY (SHELL *)

CYBERSECURITY REQUIREMENTS OUTLINED IN SECTIONS A-C

TOTAL COSTS $ -

Security Unit Price List (Level II)

REV (OCT 2024)

File details come from the government source that posted it. Updated .