Exhibit I. Security Unit Price List FSL II - Sussex County CBOC Annex.xlsx
XLSX spreadsheet 18 KB Posted
- Solicitation number
- 36C24426R0018
About this file
This is a Security Unit Price List template for a federal real estate lease solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4 for a Community-Based Outpatient Clinic (CBOC) Annex facility in Sussex County, Delaware. The lease requirement is for 7,533 rentable square feet with 6,696 assignable building occupancy area, under RLP No. 36C24426R0018 and Lease Number 36C24426L0001.
The spreadsheet is a pricing template that organizes security requirements into seven primary categories: Facility Entrances/Lobby/Common Areas, Interior Government Space, Sites and Exterior of Building, Security Systems, Structure, and Operations/Administration, with a Cybersecurity section. The template designates specific security measures as either "Priced in Shell" (landlord-provided base building costs) or requiring separate line-item pricing, including video surveillance system design and installation, intrusion detection system design and installation, duress alarm system design and installation, security system testing and maintenance, ground floor window locks with monitoring, secure air intake grilles, and emergency generator protection. The template notes that lessor design and installation costs for multiple security systems and other specified security elements are currently shown at zero cost, indicating this is a baseline framework requiring the lessor to insert actual pricing, quantities, and total costs based on the specific facility requirements and security level determined appropriate for the CBOC Annex.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Security Unit Costs
| INSTRUCTIONS TO THE LEASING SPECIALISTS: THIS SPREADSHEET REFLECTS THE BASELINE SET OF SECURITY PARAGRAPHS. EACH PARAGRAPH IN THE SECURITY SECTION WILL HAVE A CORRESPONDING LINE. IF THE SECURITY SECTION IS ADJUSTED BY ADDING OR DELETING PARAGRAPHS THE SPREADSHEET MUST BE CHANGED ACCORDINGLY. |
| Exhibit I - RLP No. 36C24426R0018 |
| SECURITY UNIT PRICE LIST (FSL II) |
| LEASE NUMBER 36C24426L0001 |
| [INSERT DATE] |
| [INSERT CLIENT NAME] |
| [INSERT CITY and STATE] |
Lease Security Standards Section Unit Price Quantity Total
| I. | FACILITY ENTRANCES, LOBBY, COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS | |
| A. | FACILITY ENTRANCES AND LOBBY | |
| 1. | EMPLOYEE ACCESS CONTROL AT ENTRANCES (SHELL) | Priced in Shell |
| B. | SCREENING REQUIREMENTS | |
| 1. | ACCOMODATION OF RETAIL/MIXED USE SPACE (SHELL) | Priced in Shell |
| C. | COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS | ||
| 1. | PUBLIC RESTROOM ACCESS (SHELL) | Priced in Shell | |
| 2. | SECURING CRITICAL AREAS (SHELL) | Priced in Shell | |
| 3. | VISITOR ACCESS CONTROL (SHELL) | Priced in Shell | |
| 4. | PUBLIC SPACE RESTRICTIONS WITH PRIMARY VERTICAL LOAD MEMBERS | $ - 0 | |
| 4a. | RESTRICT CONTACT FROM PUBLIC AREAS WITH PRIMARY VERTICAL LOAD MEMBERS | $ - 0 | |
| 4b. | RESTRICT CONTACT FROM MAIL AREAS WITH PRIMARY VERTICAL LOAD MEMBERS | $ - 0 |
| II. | INTERIOR (GOVERNMENT SPACE) | |
| A. | IDENTITY VERIFICATION (SHELL) | Priced in Shell |
| B | FORMAL KEY CONTROL PROGRAM (SHELL) | Priced in Shell |
| III. | SITES AND EXTERIOR OF THE BUILDING | |
| A. | SIGNAGE | |
| 1. | POSTING OF SIGNAGE IDENTIFYING THE SPACE AS GOVERNMENTAL (SHELL) | Priced in Shell |
| 2. | POSTING OF REGULATORY SIGNAGE (SHELL) | Priced in Shell |
| B. | LANDSCAPING AND ENTRANCES | |
| 1. | LANDSCAPING REQUIREMENTS (SHELL) | Priced in Shell |
| 2. | HAZMAT STORAGE (SHELL) | Priced in Shell |
| 3. | PLACEMENT OF RECEPTACLES, CONTAINERS, AND MAILBOXES (SHELL) | Priced in Shell |
| C. | PARKING | |
| 1. | PUBLIC ACCESS TO GOVERNMENT PARKING AREAS (SHELL) | Priced in Shell |
| IV. | SECURITY SYSTEMS | |
| A. | SECURITY SYSTEM TESTING & MAINTENANCE CRITERIA | $ - 0 |
| B. | VIDEO SURVEILLANCE SYSTEM (VSS) | |
| LESSOR PROVIDED DESIGN AND INSTALLATION | $ - 0 |
| C. | INTRUSION DETECTION SYSTEM | |
| LESSOR PROVIDED DESIGN AND INSTALLATION | $ - 0 |
| D. | DURESS ALARM | |
| LESSOR PROVIDED DESIGN AND INSTALLATION | $ - 0 |
E. SECURITY SYSTEMS DESIGN $ - 0
| V. | STRUCTURE | |
| A. | WINDOWS | |
| LOCK GROUND FLOOR WINDOWS (BSAC- IDS Monitoring) | $ - 0 |
| B. | BUILDING SYSTEMS | ||
| 1. | EMERGENCY GENERATOR PROTECTION (T.I.) | Priced in Tenant Improvements | |
| 2. | SECURE AIR INTAKE GRILLES | $ - 0 |
| VI. | OPERATIONS AND ADMINISTRATION | |
| A. | FACILITY SECURITY COMMITTEE (FSC) - (SHELL *) | Priced in Shell |
| B. | ACCESS TO BUILDING INFORMATION (SHELL *) | Priced in Shell |
| C. | CONSTRUCTION SECURITY PLAN (SHELL) | Priced in Shell |
| VII. | CYBERSECURITY (SHELL *) | ||
| CYBERSECURITY REQUIREMENTS OUTLINED IN SECTIONS A-C (SHELL *) | Priced in Shell | ||
| TOTAL COSTS | $ - 0 |
Security Unit Price List (Level II)
REV (08 2021)
&P
Security Unit Price List (Level III) REV (xx 2021) Page #
Security Unit Price List (Level II)
REV (08 2021)
&P
Security Unit Price List (Level II)
REV (OCT 2024)
&P
File details come from the government source that posted it. Updated .