Exhibit_C_-_Building_Plans._2ef14314.pdf
PDF 5 MB Posted
- Solicitation number
- ITB# CDS/ 250783A
- Issued by
- Marion County, Orlando City, Florida
About this file
Summary of Building Plans and Contract Opportunity
This document consists of comprehensive building plans and specifications for new residential construction in Ocala, Florida, specifically for the Housing Assistance Program's Woodbury Residence at 826 NW 6th Avenue. The project involves construction of a single-story, 1,064 square foot residential home (1,016 square feet livable area) designed in compliance with the Florida Building Code—Residential, 8th Edition (2023). The work encompasses complete construction including structural foundation and framing, exterior wall construction with 8-inch concrete masonry units and wood framing, roof installation with asphalt shingles, windows and doors, interior finishes including drywall and flooring, electrical systems with a 200-amp service panel, mechanical systems, plumbing installations, kitchen and bathroom fixtures, and site work including concrete driveway, sidewalk, and ADA-compliant ramps. The property is located in Ocala (Marion County), Florida, with wind speed design criteria of 130 miles per hour in Exposure C. All contractors and subcontractors must coordinate with the City Rehabilitation Specialist, Chris Lewis (352-629-8333 or 352-425-7686, clewis@ocalafl.org), and must comply with all municipal, state, and federal laws and building codes.
The building plans include detailed architectural, structural, electrical, and mechanical drawings with complete specifications for materials, fastening schedules, foundation details, framing connections, and finishes. The general contractor bears responsibility for obtaining all required permits and approvals, conducting a mandatory pre-bid site visit to verify existing conditions, coordinating all subcontractor work, maintaining a construction schedule, and ensuring work quality meets professional standards. The project is designated as Building Risk Category II, Construction Type V-B, with assumed soil bearing capacity of 2,000 pounds per square foot (subject to verification by geotechnical report). All work must be performed in strict accordance with the drawings and specifications, with any discrepancies or site condition conflicts requiring immediate notification to the design professional before proceeding. The contractor shall maintain on-site a current and complete set of construction drawings throughout the project duration.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESIGN CRITERIA
LOT INFORMATION
FLORIDA BUILDING CODE-
RESIDENTIAL
8TH EDITION (2023)
TO THE BEST OF THI DESIGN PORFESSIONAL'S KNOWLEDGE, THESE
PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUN
BUILDING
CODES AND THE APLICABLE FIRE SAFETY STANDARDS AS DETERMINED
BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER 553 AND
633 OF THE FLORIDA STATUTES AND MEET OR EXCEED THE
REQUIREMENTS
OF THE FLORIDA BUILDING CODE-RESIDENTIAL 8TH EDITION (2023),
AS DEVELOPED AND MAINTANIED BY THE FLORIDA BUILDING
COMMISSION, AND ADMINISTERED AND ENFOCED BY LOCAL
JURISDICTIONS.
COMMUNITY:
LOT: PARCEL ID: 2571-013-003
ADDRESS: 826 NW 6TH AVE., FL 34475
COUNTY: OCALA
WIND SPEED: 130
EXPOSURE: C
STRUCTURAL ENGINEER
A R C H I T E C T U R E + E N G I N E E R I N G
Service Beyond Design
License No. AR102538 License No. CA30900
SITE MAP
BUILDING LOCATION
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
IO
N
ANY DISCREPANCY OR
ERROR IN DIMENSIONS OR
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
A-001
25-14622
HOUSING ASSISTANCE PROGRAM - WOODBURRY RESIDENCE
C O
V E
R S
H E
E T
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
SHEET SCHEDULE
REV.
NO. SHEET NAME REVISION REV. DATE
3_GENERAL
A-001 COVER SHEET
A-002 GENERAL NOTES
4_ARCHITECTURAL
A-101 ARCHITECTURAL SITE PLAN
A-102 FIRST LEVEL FLOORPLAN
A-103 ROOF PLAN
A-201 EXTERIOR ELEVATIONS
A-202 EXTERIOR ELEVATIONS
A-203 EXTERIOR ISOMETRIC
A-301 BUILDING SECTIONS
AD-01 ARQUITECTURAL DETAILS
AD-02 ARQUITECTURAL DETAILS - ROOF
AD-03 ARQUITECTURAL DETAILS - DOOR /
WINDOW
AD-04 ARQUITECTURAL DETAILS - WINDOW
FLASHING
AD-05 ARCHITECTURAL DETAILS - DOOR
FLASHING
AD-06 ARQUITECTURAL DETAILS
5_ELECTRICAL
E-101 FIRST FLOOR ELECTRICAL PLAN
6_STRUCTURAL
S001 STRUCTURAL NOTES
S002 STRUCTURAL NOTES
S101 FOUNDATION PLAN
S102 ROOF FRAMING PLAN
S103 LINTEL SCHEDULE
SD100 GENERAL DETAILS
SD101 GENERAL DETAILS
SD200 FOUNDATION DETAILS - S.O.G.
SD201 FRAMING DETAILS - ROOF
AREA SCHEDULE
Name Area
LIVABLE AREA 1016 SF
NON-LIVABLE AREA 48 SF
TOTAL 1064 SF
THE ELECTRONIC SEAL
PLACED ON THESE
DOCUMENTS DOES NOT
APPLY TO THE
FOLLOWING PAGES:
E101 AND E102
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
Exhibit C - Building Plans Contract# CDS/250783A
C - 1
1. THESE DOCUMENTS HAVE BEEN PREPARED EXPRESSLY FOR USE BY FOR THE
PURPOSE OF BUILDING.
2. ANY ADDITIONAL USE OF THESE DOCUMENTS FOR ANY REASON OTHER THAN
THAT MENTIONED ABOVE MUST BE AUTHORIZED IN WRITING BY THE COPYRIGHT
HOLDER.
3. THESE DRAWINGS REFLECT DESIGN INTENT.
4. THESE DRAWINGS, AS LISTED IN THE DRAWING INDEX, ALONG WITH THE
SPECIFICATIONS & CONTRACT FOR CONSTRUCTION, CONSTITUTE THE
INSTRUMENTS OF SERVICE AND ARE CONSIDERED A SINGLE ENTITY. THE
CONTRACTOR IS THEREFORE BOUND BY ALL INFORMATION INCLUDED.
5. ONLY DRAWINGS MARKED 'ISSUED FOR CONSTRUCTION' SHALL BE USED AS A
BASIS FOR CONSTRUCTION.
6. THE TERM 'CONTRACTOR' IN THE PLANS SHALL REFER TO THE GENERAL
CONTRACTOR. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR
TO COORDINATE THE SUBCONTRACTOR WORK WITH THESE PROJECT DOCUMENTS.
CONTRACTOR SHALL PROVIDE A LIST OF
ALL SUB-CONTRACTORS TO THE CONSTRUCTION PROJECT MANAGER.
7. CONTACT CONSTRUCTION PROJECT MANAGER FOR COORDINATION OF STAGING
AND REFUSE REMOVAL PRIOR TO SIGNING THE CONTRACT FOR CONSTRUCTION.
ANY ADJUSTMENT IN THE CONTRACT AMOUNT OR DURATION DUE TO
REQUIREMENTS SHALL BE MADE PRIOR TO CONTRACT EXECUTION.
8. ALL ITEMS SHOWN ARE NEW TO BE PROVIDED & INSTALLED BY G.C. UNLESS
NOTED OTHERWISE.
9. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENT. LARGE
SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE DRAWINGS. DETAILS
TAKE PRECEDENCE OVER ALL.
10. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS AND
CONDITIONS PRIOR TO BID AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY
THE CONSTRUCTION PROJECT MANAGER AND THE ARCHITECT IMMEDIATELY OF
ANY DISCREPANCIES OR OMISSIONS PRIOR TO PROCEEDING WITH ANY WORK.
11. FOR BIDDING PURPOSES; WHERE CONFLICTS EXIST BETWEEN DRAWING
DETAILS & SPECIFICATIONS, THE MORE STRINGENT SPECIFICATION SHALL APPLY.
12. PRIOR TO SUBMITTING A PROPOSAL, ALL CONTRACTORS SHALL VISIT
HE SITE TO FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND THE
NATURE AND SCOPE OF THE WORK. THE SUBMISSION OF A PROPOSAL SHALL BE
CONSTRUED AS EVIDENCE THAT SUCH A SITE VISIT HAS BEEN MADE, AND LATE
CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED FOR DIFFICULTIES
ENCOUNTERED, WHICH COULD HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION
BEEN MADE, WILL NOT BE RECOGNIZED.
13. THE GENERAL CONTRACTOR / SUB-CONTRACTOR SHALL OBTAIN AND PAY FOR
ALL THE LEGALLY REQUIRED APPROVAL AND PERMITS NECESSARY FOR THE
EXECUTION AND COMPLETION OF THE FORWARD COPIES TO THE TENANT
CONSTRUCTION PROJECT MANAGER .
14. ALL WORK PERFORMED BY THE CONTRACTOR / SUB-CONTRACTOR SHALL
CONFORM TO THE REQUIREMENTS OF THE MUNICIPAL, LOCAL, AND STATE AND
FEDERAL LAWS, AS WELL AS ANY OTHER GOVERNING REQUIREMENTS, INCLUDING
LANDLORD REQUIREMENTS, WHETHER OR NOT SPECIFIED ON THE DRAWINGS.
15. WHERE THE CONTRACT NOTES OR DRAWINGS CALL FOR ANY WORK OR A MORE
STRINGENT NATURE THAN THAT REQUIRED BY THE BUILDING CODE OR ANY
OTHER DEPARTMENT HAVING JURISDICTION OVER THE WORK, THE WORK OF THE
MORE STRINGENT NATURE CALLED FOR BY THE CONTRACT NOTES OR DRAWINGS
SHALL BE FURNISHED IN ALL CASES.
16. ALL CONTRACTORS SHALL CONTACT THE BUILDING
MANAGEMENT/LANDLORD TO DETERMINE THE RULES OF THE BUILDING OWNER
FOR CONSTRUCTION AND DELIVERY OF EQUIPMENT AND MATERIALS.
17. PRIOR TO BEGINNING ANY WORK, THE GENERAL CONTRACTOR SHALL FURNISH
THE CONSTRUCTION PROJECT MANAGER WITH A CONSTRUCTION SCHEDULE
SHOWING THE CHRONOLOGICAL PHASES OF HIS WORK AND ALL RELATED WORK
FOR THE COMPLETION OF THE PROJECT. THIS SCHEDULE SHALL INDICATE ALL
ORDERING LEAD TIMES, LENGTH OF TIME FOR EACH PHASE AND THE PROJECTED
START AND COMPLETE DATES.
18. IT IS ASSUMED THAT THE G.C. SHALL PERFORM THE WORK AS ILLUSTRATED
WITHIN THE PERMITTED DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE
ARCHITECT IN THE EVENT THAT EXISTING SITE CONDITIONS PREVENT THE WORK
FROM BEING COMPLETED AS ILLUSTRATED HEREIN SO THAT ANY MODIFICATIONS
TO THE CONSTRUCTION DOCUMENTS (IF NECESSARY) CAN BE MADE. ANY
DEVIATIONS FROM THE PERMITTED DRAWINGS WILL NOT BE ACCEPTABLE, AND
THE CONTRACTOR SHALL RECONFIGURE THE WORK AT HIS OWN EXPENSE, AS
REQUIRED TO BE IN CONFORMANCE WITH THE PERMITTED DOCUMENTS. THE
ARCHITECT WILL NOT ACCEPT, CERTIFY, OR DOCUMENT ANY WORK THAT DOES
NOT CONFORM TO THE PERMITTED DOCUMENTS FOR THE PURPOSES OF
OBTAINING ANY ADDITIONAL MUNICIPAL APPROVAL REQUIRED DUE TO
UNAUTHORIZED REVISIONS.
19. THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET
OF CONSTRUCTION DRAWINGS ON SITE THROUGHOUT THE DURATION OF
CONSTRUCTION FOR USE BY ALL TRADES.
20. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES, AND WORK AREAS SHALL
BE LEFT IN A CLEAN CONDITION ON A DAILY BASIS.
21. THE GENERAL CONTRACTOR SHALL EXERCISE STRICT DUST CONTAINMENT
CONTROL OVER THE JOB SITE TO PREVENT DUST FROM ESCAPING.
22. THE GENERAL CONTRACTOR SHALL PROPERLY PROTECT THE GENERAL
BUILDING AREAS AND ANY ADJOINING PROPERTY OR WORK FROM DAMAGE
DURING CONSTRUCTION, AND SHALL PATCH OR REPLACE ANY DAMAGED WORK OR
MATERIALS WITHOUT DELAY.
23. ANY DAMAGE BY G.C. OR SUBCONTRACTOR TO EXISTING ASPHALT PAVEMENT
AND/OR EXISTING LANDSCAPING OUTSIDE OF CONSTRUCTION LIMIT LINE SHALL
BE REPAIRED AT NO COST TO OWNER OR TENANT.
24. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION. ALL
REQUIRED EXITS AND EGRESS PATHWAYS SHALL BE CONTINUOUSLY MAINTAINED
FREE FROM ALL OBSTRUCTIONS AND IMPEDIMENTS IN THE CASE OF A FIRE OR
OTHER EMERGENCY. ALL EXISTING EXIT LIGHTING, FIRE PROTECTIVE DEVICES
AND ALARMS SHALL BE CONTINUOUSLY MAINTAINED.
25. NO MATERIALS SHALL BE STORED ON PUBLIC PROPERTY UNLESS AN
ENCROACHMENT PERMIT IS FIRST OBTAINED FROM THE PUBLIC WORKS DEPT.
26. EACH TRADE SHALL PROVIDE CAULKING OR SEALANT WHERE REQUIRED.
27. PROVIDE STRUCTURAL SUPPORTS AS REQUIRED AT ALL WALL MOUNTED
EQUIPMENT, CABINETS, PLUMBING AND LIGHT FIXTURES.
28. MANUFACTURER'S NAME, TRADEMARK, LOGOS, ETC., SHALL NOT BE VISIBLE TO
THE PUBLIC.
29. ALL FLOOR SLAB CUTTING, TRENCHING AND REMOVAL SHALL BE REPLACED
WITH THE SAME MATERIAL IN THE SAME THICKNESS OF THE ADJACENT FLOOR
MATERIAL. ADDITIONAL CONCRETE PATCHING SHALL BE DOWELED INTO THE
ADJACENT CONCRETE SLAB TO MINIMIZE DIFFERENTIAL SETTLEMENT OF THE
FLOOR SYSTEM.
30. ALL ROOF PENETRATIONS ARE TO BE PERFORMED BY PROJECT/CONSTRUCTION
MANAGER'S ROOFING CONTRACTOR. CONTACT PROJECT/CONSTRUCTION MANAGER
TO COORDINATE.
31.ALL WALL, FLOOR, CEILING, ETC. PENETRATIONS ARE TO BE DRAFT OR
FIRESTOPPED (WHERE REQUIRED TO MATCH FIRE COMPARTMENTS). ASSURE NO
AIR LEAKAGE, PARTICULARLY WHEN A PLENUM IS IN USE.
GENERAL NOTES FIRE & SAFETY NOTES
CORRIDORS AND OPENINGS
1. DOORS OPENING INTO A ONE-HOUR FIRE RESISTIVE CORRIDOR SHALL BE
PROTECTED WITH A SMOKE OR DRAFT-STOP FIRE ASSEMBLY HAVING A MINIMUM
20 MINUTE RATING AND SELF-CLOSING DEVICE.
2. SMOKE/FIRE DAMPERS OR DOORS SHALL BE PROVIDED WHERE DUCTS
PENETRATE FIRE RATED WALLS OR CEILINGS.
INTERIOR FINISHES - SEE FBC TABLE 803.11
1. INTERIOR WALL AND CEILING FINISHES SHALL NOT EXCEED A FLAME SPREAD
CLASSIFICATION OF 200 (CLASS III).
2. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDORS SHALL NOT
EXCEED A FLAME SPREAD CLASSIFICATION OF BETWEEN 26 AND 75 (CLASS II).
3. INTERIOR WALL AND CEILING FINISHES FOR 2 HOUR EXIT CORRIDORS SHALL
NOT EXCEED A FLAME SPREAD CLASSIFICATION OF BETWEEN 0 AND 25 (CLASS I).
4. CEILING TILES TO BE MINERAL FIBER WITH UL LABEL AND FLAME SPREAD
RATING OF 25 OR LESS.
EXITS
1. EVERY EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE
OF A KEY, TOOL OR SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES
SHALL BE AN APPROVED TYPE.
2. PANIC HARDWARE SHALL BE PROVIDED IN EXIT DOORS SERVING ROOMS,
CORRIDORS OR STAIRWAYS HANDLING AN OCCUPANCY OF 50 OR MORE PERSONS.
3. AISLES LEADING TO REQUIRED EXITS SHALL HAVE A MINIMUM WIDTH OF 44"
CLEAR.
FIRE ALARM
1. EXTEND OR MODIFY EXISTING FIRE/LIFE SAFETY SYSTEM AS REQUIRED BY
CODE.
2. SUBMIT COMPLETE SETS OF PLANS TO THE ELECTRICAL DIVISION OF THE LOCAL
DEPARTMENT OF BUILDING AND SAFETY AND TO THE FIRE DEPARTMENT. VERIFY
WITH LOCAL JURISDICTION FOR NUMBER OF SETS REQUIRED.
SIGNS AND EMERGENCY LIGHTING
1. PROVIDE EXIT SIGNS AND DIRECTIONAL EXIT SIGNS WITH A MINIMUM 6" HIGH
BY 3/4" STROKE BLOCK LETTERS ON A CONTRASTING BACKGROUND.
2. WHENEVER BUILDING IS OCCUPIED, EXIT SIGNS SHALL BE LIGHTED SO THAT
THEY ARE CLEARLY VISIBLE.
3. EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED. LED LAMPS SHALL BE
ENERGIZED FROM SEPARATE CIRCUITS. ILLUMINATION SHALL NORMALLY BE
PROVIDED BY THE PREMISE'S WIRING IN THE EVENT OF FAILURE OF THIS SYSTEM,
ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM BATTERY BACK-UP.
4. EMERGENCY LIGHTING SHALL GIVES A VALUE OF ONE FOOT CANDLE AT FLOOR
LEVEL. VERIFY IF ILLUMINATED SIGNS ARE TO HAVE BATTERY BACKUP.
5. EXIT PATH LIGHTING SHALL BE PROVIDED FOR STAIRWAY, HALLWAY, EXIT
PASSAGEWAY AND EGRESS TO A PUBLIC WAY ANYTIME THE BUILDING IS
OCCUPIED. EMERGENCY LIGHTING SHALL BE PROVIDED GIVING LIGHT VALUE OF
ONE FOOT CANDLE AT THE FLOOR LEVEL.
6. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN
2-A-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE
BUILDING ON EACH FLOOR AND DURING CONSTRUCTION. VERIFY WITH LOCAL
JURISDICTION ON DISTANCE FOR FIRE EXTINGUISHERS.
7. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE DEPARTMENT FIELD
INSPECTOR.
8. REFER TO FIRE SYSTEMS DRAWINGS FOR TYPICAL MOUNTING HEIGHTS OF FIRE
PROTECTION EQUIPMENT.
9. MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHER SYSTEM, AS NEEDED, TO BE
APPROVED BY BUILDING AND SAFETY FIRE DEPARTMENT PRIOR TO INSTALLATION.
PARTITION NOTES
1. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL PARTITIONS
DESIGNATED ON ARCHITECTURAL PLANS.
2. UNLESS OTHERWISE NOTED, ALL DIMENSIONS FOR PARTITIONS ARE FROM
FINISH FACE OF NEW WALLS / FINISH FACE OF EXISTING WALLS. ALL HEIGHTS
ARE FROM THE TOP OF THE FINISHED FLOOR.
3. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH
AND SMOOTH WITH BASE BUILDING STRUCTURE UNLESS OTHERWISE NOTED.
4. THE GENERAL CONTRACTOR SHALL USE CORNER BEADS AT ALL EXPOSED
CORNERS AND EXPOSED ENDS IN PLASTER AND DRYWALL PARTITIONS.
5. ALL PARTITIONS SHALL BE ANCHORED FIRMLY AS PER MANUFACTURERS
SPECIFICATIONS AND AS REQUIRED BY STATE AND LOCAL CODES.
6. THE GENERAL CONTRACTOR SHALL SUPPLY ALL RETURN AIR OPENINGS IN SLAB
TO SLAB PARTITIONS ABOVE HUNG CEILINGS TO MATCH AREA CALCULATION
REQUIREMENTS AS SHOWN ON ENGINEERING DRAWINGS. ALL OPENINGS IN
DEMISING AND SOUND ATTENUATED WALLS TO HAVE SOUND BOOTS. OPENINGS
IN FIRE RATED WALLS SHALL HAVE FIRE DAMPERS AS REQUIRED BY LOCAL
BUILDING CODES. CONTRACTOR TO COORDINATE WITH ENGINEERING DRAWINGS
AND INFORM THE ARCHITECT OF DISCREPANCIES PRIOR TO BID PROCESS.
7. THE GENERAL CONTRACTOR SHALL PROVIDE SUFFICIENT FRAMING FOR ALL
WALL PARTITIONS FOR DUCT WORK, RETURN AIR OPENINGS AND GRILL
OPENINGS ABOVE AND BELOW HUNG CEILING. THESE ARE TO BE COORDINATED
WITH HVAC ENGINEERING DRAWINGS AND THE MECHANICAL CONTRACTOR'S
SHOP DRAWINGS. ALL OPENINGS SHALL BE PROPERLY SEALED FOR
SOUNDPROOFING AND VIBRATION.
8. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL ACCESS PANELS
AS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING INSTALLATIONS PER
LOCAL BUILDING CODES. LOCATIONS SHALL BE COORDINATED WITH THE TENANT
CONSTRUCTION PROJECT MANAGER & LANDLORD PRIOR TO FINAL INSTALLATION.
9. THE GENERAL CONTRACTOR WILL NOT BE ENTITLED TO EXTRAS FOR OPENING
ANY PARTITIONS BECAUSE OF TELEPHONE INSTALLATION, SECURITY SYSTEMS OR
COMPUTER DATA SYSTEMS.
10. THE CONSTRUCTION PROJECT MANAGER SHALL HAVE THE RIGHT TO REVIEW
AND APPROVE ALL CHALK LINES PRIOR TO INSTALLATION OF TRACK. THE
ARCHITECT IS TO BE NOTIFIED OF ANY REQUIRED DEVIATION FROM
CONSTRUCTION DIMENSIONS OR CLEARANCES AS DESIGNATED ON PLAN OR OF
ANY APPARENT CONSTRUCTION CONFLICTS.
11. THE GENERAL CONTRACTOR IS TO VERIFY PRIOR TO PRICING THE RATING OF
THE PARTITIONS, COLUMNS, ETC. THE GENERAL CONTRACTOR SHALL PROVIDE
WALL FURRING AT PARTITIONS WITH A RATING OF GREATER THAN 1 HOUR AS
NECESSARY TO ACCOMMODATE ELECTRICAL OR PLUMBING CONDITIONS AS
INDICATED ON THIS DOCUMENT.
12. DRYWALL: LEVEL 5 FINISH REQUIRED THROUGHOUT (WALLS, SOFFITS, ETC.).
ALL JOINTS AND INTERIOR ANGLES SHALL BE TAPED EMBEDDED IN JOINT
COMPOUND AND THREE COATS OF JOINT COMPOUND APPLIED OVER ALL JOINTS,
ANGLES, FASTENER HEADS, AND ACCESSORIES. ALL JOINT COMPOUND SHALL BE
SMOOTH AND FREE OF TOOL MARKS AND RIDGES.
MILLWORK NOTES
PATCHING NOTES
PAINT & WALL COVERING NOTES
DOOR NOTES
FLOORING NOTES
PAINT & WALL COVERING NOTES CEILING NOTES
CLEANING NOTES
DEMOLITION NOTES
TABLE 803.11 - INTERIOR FINISHES
1. THE GENERAL CONTRACTOR SHALL CLOSELY COORDINATE HIS WORK WITH THAT
OF THE CABINET CONTRACTOR.
2. ALL "INSTALLED" CABINETS SHALL BE SCRIBED TO WALL OR CEILING. CABINET
CONTRACTOR SHALL CHECK JOB PROGRESS AND COORDINATE WITH OTHER TRADES
INVOLVED.
3. ALL CABINET FINISHES SHALL BE AS NOTED ON THE DETAILS DRAWINGS
CONCERNED.
4. THE CABINET CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND SAMPLES TO THE
ARCHITECT.
5. THE CABINET SHALL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AT
THE JOB SITE.
6. THE CABINET CONTRACTOR SHALL PROVIDE RUBBER BUMPERS ON ALL WOOD
DOORS.
7. WHERE MEMBERS ARE MITERED OR BUTTED, THEY SHALL BE JOINED AND SECURED
IN A MANNER TO INSURE AGAINST THE JOINT OPENING.
8. ALL FINISHED WORK SHALL, AS FAR AS PRACTICAL, BE ASSEMBLED AND FINISHED
IN THE SHOP AND DELIVERED TO THE BUILDING READY TO ERECT IN PLACE.
9. ALL THE WORK SHALL BE FABRICATED, ASSEMBLED, FINISHED AND ERECTED TO
MEET CURRENT WIC STANDARDS.
10. WHERE FILES ARE SHOWN AS BEING SET INTO CABINET WORK, THE CABINET
CONTRACTOR SHALL SET AND BOLT ALL FILES TOGETHER.
11. ALL MILLWORK SHOP DRAWINGS ARE TO CALL OUT ALL MATERIALS AND
FINISHES. ALL JOINTS, CORNERS AND EDGES ARE TO BE DETAILED IN INDIVIDUAL
DETAILS. ALL DIMENSIONS, CRITICAL OR OTHERWISE, ARE TO BE CALLED OUT ON
THE SHOP DRAWINGS. THE ARCHITECT WILL NOT REVIEW DRAWINGS WHICH ARE
INCOMPLETE AND SHOW MINIMAL DETAILING.
12. COORDINATION OF MILLWORK, STONE, OR OTHER SPECIALTY CONTRACTORS IS
THE RESPONSIBILITY OF THEGENERAL CONTRACTOR.
13. ALL MILLWORK, SPECIAL PRODUCTS, AND SPECIAL ASSEMBLIES ARE SUBJECT TO
SUBMITTAL AND SHOP DRAWINGS REVIEW. SHOP DRAWINGS AND SUBMITTAL'S
SHALL NOT BE WAIVED UNLESS WRITTEN PERMISSION TO DO SO IS GIVEN BY THE
ARCHITECT.
14. ALL STANDARD WALL BACKING FOR CASEWORK, TOILET ACCESSORIES, HANGING
WALL EQUIPMENT, ETC., SHALL BE 16 GA. GALVANIZED STEEL, 4" WIDE, COVERING 3
STUDS MINIMUM AND SCREWED TO METAL STUDS.
15. ALL MILLWORK SHOWN SHALL HAVE PLASTIC LAMINATE TOPS, EXPOSED SIDES,
DOORS, AND DRAWER FRONTS, UNLESS OTHERWISE NOTED.
16. SHELVES AND SEMI-EXPOSED SURFACES, INCLUDING DRAWER INTERIORS, SHALL
BE FINISHED WITH A CABINET LINER OF A UNIFORM COLOR THROUGHOUT.
17. ADJUSTABLE METAL STANDARDS SHALL BE DAPPED INTO THE SIDES OF
CABINETS, UNLESS OTHERWISE NOTED.
18. DOOR AND DRAWER PULL HARDWARE SAMPLES ARE TO BE SUBMITTED TO THE
ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION.
1. THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, FITTING, AND PATCHING
WORK THAT MAY BE REQUIRED TO MAKE ALL PARTS COME TOGETHER PROPERLY
AND FIT TO RECEIVE OR BE RECEIVED BY WORK OF OTHER CONTRACTORS SHOWN
UPON OR REASONABLY IMPLIED BY THE DRAWINGS AND NOTES.
2. THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR CUT-OUTS AND PATCHING
REQUIRED FOR THE INSTALLATION OF ALL WORK.
3. THE GENERAL CONTRACTOR SHALL SURVEY ALL EXISTING FINISHED SURFACES
INCLUDING CORNER BEADS, STOPS, ETC. FOR CHIPS, CRACK HOLES, DAMAGED
SURFACES AND DEFECTS AND REPAIR SAME TO THE SATISFACTION OF PROJECT
MANAGER.
4. WHERE DOOR BUCKS HAVE BEEN REMOVED, REPAIR GAPS AND SURFACES TO
ACHIEVE A CLASS I FINISH TO THE SATISFACTION OF CONSTRUCTION PROJECT
MANAGER.
5. THE GENERAL CONTRACTOR SHALL METAL LATH OVER ALL NEW CONDUIT CHASES
IN MASONRY PARTITIONS.
6. ALL DAMAGED EXISTING AREAS TO REMAIN AND EXISTING AREAS AFFECTED BY
DEMOLITION OR NEW CONSTRUCTION WORK SHOWN ON DRAWINGS SHALL BE
PATCHED AS REQUIRED TO MATCH IMMEDIATE EXISTING ADJACENT AREAS IN
MATERIALS, FIRE RATING, FINISH AND COLOR UNLESS OTHERWISE NOTED.
7. ALL FIRE PROOFING REMOVED FROM COLUMNS AND BEAMS DURING THE COURSE
OF CONSTRUCTION SHALL BE REPLACED WITH THE SAME MATERIAL AND RATING AS
THAT WHICH WAS REMOVED.
1. UNLESS OTHERWISE SPECIFIED, ALL AREAS ARE TO BE PAINTED IN ACCORDANCE
WITH FINISH PLANS.
2. WALLS SHALL INCLUDE SURFACES FROM FLOOR TO CEILING, INCLUDING
PILASTERS, FACIAS, JAMBS BUCKS, REVEALS, RETURNS, AND ALL VERTICAL
SURFACES NOT INCLUDED IN CEILING.
3. PAINT COLORS SHALL BE SPECIFIED BY THE OWNER AND THE GENERAL
CONTRACTOR SHALL SUBMIT 3 SAMPLES (12" X 12") FOR REVIEW BY THE OWNER /
ARCHITECT.
4. ALL WALLS AND CEILINGS SHALL BE PROPERLY PREPARED, SPACKLE, SANDED,
ETC. TO PROVIDE A PERFECTLY SMOOTH FINISH AND SURFACE READY FOR PRIME
AND PAINT.
5. ALL EXISTING LOOSE PAINT SHALL BE REMOVED AND SPACKLE OR PLASTER
PATCHED.
6. ALL EXISTING UNEVENNESS IN ALL PARTITIONS SHALL BE SANDED OR CHIPPED
AWAY AND SURFACES PLASTER-PATCHED OR SPACKLE TO INSURE A PERFECTLY
EVEN SURFACE.
7. ALL WOOD SHELVING AND PAINTED DOORS SHALL RECEIVE PRIMING, SANDING
AND TWO FULL COATS OF SEMI-GLOSS ENAMEL FREE OF BRUSH MARKS, UNLESS
OTHERWISE NOTED.
8. THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL SWITCH PLATES AND OUTLET
PLATES, SURFACE HARDWARE, ETC., PRIOR TO PAINTING, PROTECTING AND
REPLACING SAME WHEN PAINTING HAS BEEN COMPLETED. HE SHALL REMOVE ALL
PAINT FROM WHERE IT HAS SPILLED, SPLASHED OR SPLATTERED ON SURFACES,
INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, DIFFUSERS, REGISTERS AND
SLAB FITTINGS, ETC.
9. THE CONTRACTOR SHALL USE A LATEX BASE PAINT IN COLORS AND FINISHES
SELECTED BY THE ARCHITECT. HE SHALL PROPERLY PREPARE ALL SURFACES TO
RECEIVE ONE (1) PRIME COAT AND TWO (2) FINISH COAST OF PAINT IN COLOR
SELECTED BY THE ARCHITECT.
10. THE CONTRACTOR SHALL EXAMINE ALL AREAS OF CONSTRUCTION AFTER
COMPLETION OF WORK BY ALL TRADES (INCLUDING TELEPHONE INSTALLATION,
FLOORING, ETC.) AND INDICATE ALL NECESSARY "TOUCH-UP" PAINTING AND/OR
PATCHING.
11. IT IS THE INTENT OF THE DRAWINGS THAT ALL EXPOSED SURFACES RECEIVE
FINISHES AS INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS UNLESS
SPECIFICALLY NOTED OTHERWISE.ANY SURFACES WHICH DO NOT HAVE A SPECIFIC
FINISH NOTED OR ARE NOTED TO REMAIN UNFINISHED SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT AND FINISHED PER THE ARCHITECT'S INSTRUCTION.
12. PAINT FRONT SIDE, BACK SIDE AND DOOR EDGES AT STRIKE SIDE AND HINGE SIDE.
LEAVE TOP AND BOTTOM UNPAINTED TO PREVENT WARPING.
13. PAINT ALL METAL ACCESS DOORS AND ACCESS PANELS TO MATCH ADJACENT WALL
OR CEILING FINISH. GRAPHICS ON DOOR OR PANEL (IF ANY) ARE TO BE REPAINTED/RE-
APPLIED TO MATCH EXISTING, IF APPLICABLE.
14. CLOSET WALL SURFACES ARE TO BE PAINTED TO MATCH THE COLOR OF THE
ADJACENT OUTSIDE WALL SURFACES.
1. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL REQUIRED BUCKS AND
ASSEMBLIES AS SHOWN ON ARCHITECTURAL DRAWINGS UNLESS OTHERWISE NOTED.
2. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL DOORS AS SPECIFIED ON THE
ARCHITECTURAL DRAWINGS UNLESS OTHERWISE NOTED.
3. ALL LOCK SETS SHALL BE CODED AND/OR KEYED IN ACCORDANCE WITH THE BUILDING
REQUIREMENTS. CODES AND/OR KEYS ARE TO BE DELIVERED TO TENANT PROPERLY TESTED
AND/OR TAGGED. THE NUMBER OF MASTER AND PASS KEYS SHALL BE COORDINATED WITH
BUILDING MANAGEMENT.
4. DETAILED DOOR AND HARDWARE SCHEDULES SHALL BE SUBMITTED TO THE ARCHITECT
FOR REVIEW, AND FABRICATION OF MATERIAL SHALL NOT BE COMMENCED UNTIL SUCH
REVIEW HAS BEEN RETURNED.
5. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8 1/2 POUNDS FOR EXTERIOR
DOORS AND 5 POUNDS FOR INTERIOR DOORS, SUCH PULL/PUSH EFFORT BEING APPLIED AT
RIGHT ANGLES TO HINGED DOORS AND AT THE CENTER PLANE OF THE SLIDING OR FOLDING
DOORS.
COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE
ABOVE WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR
MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE,
NOT TO EXCEED 15 POUNDS.
6. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A
SMOOTH UNINTERRUPTED SURFACE.
7. ALL REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 32" CLEAR OPENING WITH THE
DOOR AT 90° TO THE CLOSED POSITION.
8. WHERE DOORS ARE IN PAIRS, ONE OF A PAIR OF DOORS SHALL MEET THE MINIMUM
WIDTH REQUIREMENTS
9. MAXIMUM HEIGHT OF THRESHOLD TO BE 1/2" MAXIMUM VERTICAL CHANGE AT EDGE IS
1/4" WITH A MAXIMUN BEVEL OF 45°.
10. LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND WHICH ARE IN THE
PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE,
PANIC BARS, PUSH PULL ACTIVATING BARS, OR BARS OR OTHER HARDWARE DESIGNED TO
PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE.
11. SEE SHEET A8.1 FOR REQUIREMENTS OF DOORS, WINDOWS, AND HARDWARE, DOOR
SCHEDULE, HARDWARE SCHEDULE AND DOOR AND WINDOW DETAILS.
12. DIMENSIONS TO EDGE OF DOOR LOCATING DOOR OPENINGS ARE TO INSIDE FACE OF
JAMB, UNLESS OTHERWISE NOTED.
13. DOOR OPENINGS ARE TO BE LOCATED SO THAT INSIDE FACE OF BUTT SIDE JAMB IS 4"
FROM FACE OF PERPENDICULAR WALL AT CORNER, ALLOWING FOR A 90 DEGREE SWING
TYPICAL, UNLESS OTHERWISE NOTED.
14. SEE SHEET A8.1 FOR SPECIFIC DOOR AND HARDWARE REQUIREMENTS.
15. UNDERCUT BUILDING STANDARD INTERIOR DOORS AS REQUIRED TO CLEAR FINISHED
FLOOR BY 1/4". ALL RATED DOORS SHALL BE ORDERED SO AS TO CLEAR THE FINISHED
FLOOR BY 1/4", UNLESS OTHERWISE NOTED.
16. UNDERCUT RESTROOM DOORS 3/4" TO PROVIDE RETURN AIR FLOW FOR NEGATIVE AIR
FLOW FOR EXHAUST FANS.
17. ANY GLAZING ON OR WITHIN 24" OF A DOOR (IN THE SAME PLACE) SHALL BE TEMPERED.
1. FACIAS OR ANY BREAK IN THE CEILING HEIGHTS CREATED BY THE INSTALLATION AND/OR
ALTERATION OF HEATING, VENTILATING, AIR CONDITIONING OF MECHANICAL DUCTS, PIPING
OR OTHER EQUIPMENT SHALL BE FORMED OF GYPSUM WALLBOARD ON FURRING CHANNELS.
HUNG CEILING HEIGHTS SHALL BE AS SHOWN ON ARCHITECTURAL DRAWINGS AND DETAILS.
2. ANY DEVIATION FROM HEIGHTS SHOWN WILL BE SUBMITTED TO THE CONSTRUCTION
PROJECT MANAGER FOR REVIEW.
3. THE GENERAL CONTRACTORS CEILING CONTRACTOR SHALL CLOSELY COORDINATE HIS
WORK WITH THAT OF THE FIXTURE, PLUMBING HVAC ELECTRICAL CONTRACTORS AND THE
TELEPHONE COMPANY WHENEVER THEIR RESPECTIVE WORK IS CONTIGUOUS.
4. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CEILING ACCESS PANELS IN
GYPSUM BOARD CEILINGS AS REQUIRED TO FURNISH ACCESS TO ALL AIR HANDLING UNITS,
PHONE AND ELECTRICAL CONTROLS AS REQUIRED BY LOCAL BUILDING CODES. COORDINATE
LOCATIONS WITH CONSTRUCTION PROJECT MANAGER PRIOR TO FINAL INSTALLATION.
5. PRIOR TO CLOSING UP ANY CEILING, ALL PLENUM SYSTEMS (HVAC, PLUMBING AND
ELECTRIC) SHALL BE INSPECTED AND WHERE REQUIRED, TESTED BY CONTRACTOR'S
ENGINEERS AND BY AUTHORITIES HAVING JURISDICTION TO INSURE THEIR PROPER
INSTALLATION AND FUNCTION.
6. THE CEILING TILE JOINTS SHALL BE ALIGNED PERFECTLY WITH RECESSED LIGHTING
FIXTURES.
7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL, AND PERFECTLY ALIGNED WITH
EACH OTHER AND WITH THE RECESSED LIGHTING FIXTURES.
8. CEILINGS IN CLOSETS SHALL BE OF THE SAME HEIGHTS AND CONSTRUCTION AS THAT OF
ADJOINING SPACE, EXCEPT AS OTHERWISE NOTED.
9. THE GENERAL CONTRACTOR SHALL PROVIDE CUT-OUTS AND OTHER SPECIAL PROVISIONS IN
ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS AND
OTHER INSERTED ITEMS.
10. SUSPENDED CEILING SHALL BE CONSTRUCTED IN ACCORDANCE WITH STATE AND LOCAL
CODE FOR FIREPROOF STRUCTURES AND SMOKE CONTROL.
11. THE GENERAL CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY AND ALL CEILING TILES
WHICH ARE REMOVED TO FACILITATE PLENUM SYSTEM INSTALLATIONS.
12. THE GENERAL CONTRACTOR WILL NOT BE ENTITLED TO EXTRAS FOR OPENING ANY
CEILING BECAUSE OF TELEPHONE INSTALLATION, SECURITY SYSTEMS OR COMPUTER DATA
SYSTEMS.
13. PROVIDE BLOCKING/BACKING AND CEILING REINFORCEMENT FOR ALL CEILING MOUNTED
ITEMS, (PLASMA SCREENS, ETC.).
1. THE GENERAL CONTRACTOR SHALL FLASH PATCH ALL CRACKS, HOLES OR OTHER IMPERFECTIONS
(PROJECTIONS SHALL BE REMOVED AND PATCHED TO PROVIDE A CONTINUOUS SMOOTH FLOOR
SURFACE). LEVEL NOT TO EXCEED 1/4" IN 10-0" NON-CUMULATIVE.
2. THE GENERAL CONTRACTOR SHALL NOTIFY THE CONSTRUCTION PROJECT MANAGER AFTER FLOOR
PATCHING IS DONE AND RECEIVE THEIR REVIEW PRIOR TO INSTALLATION OF FINISHED FLOORING.
3. ALL NEW FLOORING IS TO BE INSTALLED BY GENERAL CONTRACTOR AND SHALL BE AS SPECIFIED
ON THE ARCHITECT'S CONSTRUCTION DOCUMENTS.
4. ALL WORKMANSHIP SHALL BE OF THE BEST QUALITY AND WHEN THE WORK IS COMPLETE, IT SHALL
BE FREE FROM BUCKLES, BUBBLES, OPEN JOINTS OR OTHER IMPERFECTIONS. SEAMS SHALL BE KEPT
IN ACCURATE ALIGNMENT ALONG BOTH COORDINATES. TILE HAVING CHIPPED OR ROUNDED
CORNERS WILL BE REJECTED AND IF LAID, SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE
TILE.
5. TILE SHALL BE LAID IN SQUARE PATTERN WITH COURSES PARALLEL TO WALLS, UNLESS OTHERWISE
NDICATED ON DRAWINGS. THE TILE SHALL BE SECURELY CEMENTED AND SHALL BE LAID WITH TIGHT
JOINTS.
6. THE ADHESIVE USED FOR CEMENTING TILE SHALL BE APPLIED FAR ENOUGH IN ADVANCE OF THE
SETTING TO PERMIT THE ADHESIVE TO REACH ITS INITIAL SET BUT NOT ITS FINAL SET.
7. SPACES BEING SURFACED SHALL BE CLOSED TO TRAFFIC AND OTHER WORK DURING THE LAYING
OF FLOORING. TILE FLOORS SHALL BE COVERED AFTER INSTALLATION FOR PROTECTION.
8. ALL RESILIENT BASE TO BE AS SPECIFIED PER PLANS..
9. UPON COMPLETION, ALL WORK SHALL BE CLEANED BY THE CONTRACTOR REMOVING ALL SPOTS OF
ADHESIVE AND SURFACE STAINS AND ALL SCRAPS. CARTONS AND CONTAINERS SHALL BE REMOVED
FROM THE BUILDING.
10. AFTER CLEANING, THE GENERAL CONTRACTOR SHALL GIVE SHEET VINYL FLOOR TWO (2)
APPLICATIONS OF AN APPROVED NON-SLIP WAX WHICH IS TO BE THOROUGHLY MACHINE BUFFED
AND LEFT IN CONDITION ENTIRELY SATISFACTORY TO THE TENANT CONSTRUCTION PROJECT
MANAGER .
11. THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE PROTECTION FOR ALL
RESILIENT FLOORING WORK FOR THE DURATION OF THE CONTRACT, AND REMOVE ALL PROTECTION
PRIOR TO PUNCH LIST.
14. THE GENERAL CONTRACTOR TO COORDINATE ALL FLOORING CONTRACTORS INVOLVED TO
ASSURE FLUSH INSTALLATION OF ALL VARYING FLOOR MATERIALS USED. ALL TRANSITION METHODS
TO BE APPROVED BY THE TENANT CONSTRUCTION PROJECT MANAGER .
15. PROVIDE BLACK RUBBER REDUCER STRIP WHERE ECO SURFACES RUBBER FLOORING AND VCT
TRANSITION OCCURS, UNLESS OTHERWISE NOTED.
1. THE NEW ITEMS INSTALLED BY THE GENERAL CONTRACTOR IN ADDITION TO
BEING AMPLY PROTECTED THROUGHOUT THE PERIOD OF CONSTRUCTION SHALL BE
THOROUGHLY CLEANED TO THE SATISFACTION OF THE PRIOR TO TURNOVER.
2. THE BASE BUILDING TOILET FACILITIES SHALL BE AMPLY PROTECTED
THROUGHOUT THE PERIOD OF CONSTRUCTION AND ALL DAMAGED OR
MALFUNCTIONING ITEMS SHALL BE REPAIRED, REPLACED AND/OR THOROUGHLY
CLEANED TO THE SATISFACTION OF THE CONSTRUCTION PROJECT MANAGER PRIOR TO
TURNOVER.
3. ALL CONSTRUCTION ACTIVITY IS TO NOT INTERFERE WITH THE DAILY
OPERATING OF THE EXISTING OFFICE BUILDING.
1. COORDINATE ALL DEMOLITION WITH FACILITIES.
2. ALL DEMOLITION MUST BE PERFORMED IN A MANNER TO CONTAIN DUST AND PARTICLES.
3. AREA MUST REMAIN CLEAN, SAFE, AND OCCUPABLE.
4. ALL SYSTEMS MUST REMAIN FUNCTIONAL DURING DEMOLITION.
TABLE 803.11 - INTERIOR WALL & CEILING FINISH REQUREMENTS FOR GROUP R2, RESIDENTIAL
SPRINKLED
EXIT ENCLOSURES AND EXIT PASSAGEWAYS = C
CORRIDORS = C
ROOMS & ENCLOSED SPACES = C
Class C: = Flame spread index 76-200; smoke-developed index 0-450.
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
A-002
25-14622
G E
N E
R A
L N
O T
E S
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 2
PROPERTY LINE
PROPERTY LINE
DRIVEWAY
SLOPED SIDEWALK
FROM DRIVEWAY LEVEL
TO PORCH LEVEL
N.W. 6th AVENUE
S E A T B A C K S
SEATBACKS
8' - 0"
P R
O P
E R
T Y
L
IN
E
P R
O P
E R
T Y
L
IN
E
N .W th
P L A C E
12' - 0"
SEATBACK
8' - 0"
22' - 0"
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
A-101
25-14622
A R
C H
IT
E
C T
U R
A L
S
IT
E P
L A
N
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
1" = 10'-0"1 ARCHITECTURAL SITE PLAN
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 3
R E
F /F
R E
E Z
E
R WALL LEGEND
6" WOOD FRAME WALL
8" CMU WALL
4" WOOD FRAME WALL
A-301
38' - 0"
14' - 0" 12' - 0" 12' - 0"
3' - 10" 10' - 2"
4"
5' - 4" 6' - 4" 4' - 0" 8' - 0"
3' - 10" 10' - 2" 24' - 0"
38' - 0"
E.E.R.O.
SH
4 0 5 0
E.E.R.O.
SH
4 0 5 0
E.E.R.O.
SH
4 0 5 0
SH
4 0 5 0
B F
B F
A.D.
2 8 6 8
A.D.
2 8 6 8
B F
2 6 6 8
A.D.
2 8 6 8
BF
1 4 6 8
BF
1 6 6 8
A .D
BEDROOM 2
8' - 0" CLG
BEDROOM 1
8' - 0" CLG
BATH
8' - 0" CLG
MASTER BEDROOM
8' - 0" CLG
MASTER BATH
8' - 0" CLG
WIC
8' - 0" CLG
WH
L
IN
E
NA/C
W/D
8' - 0" CLG
KIT/DINING
8' - 0" CLG
GREAT ROOM
8' - 0" CLG
PORCH
8' - 0" CLG
/8
8"
10' - 4" 2' - 8"
12' - 8" 4' - 6" 6' - 6"
8"
9' - 0" 16' - 8" 4' - 10" 3' - 8" 2' - 6"
10' - 4" 2' - 8" 12' - 8" 11' - 0"
/2
13' - 8" 10' - 0" 14' - 4"
0" FF
DW
A-301
2x6
2x6
1' - 0" 3' - 0"
30 IN. X 80 IN. 6 PANEL TEXTURED
HOLLOW CORE PRIMED
COMPOSITE INTERIOR DOOR SLAB
WITH KWIKSET TUSTIN SMARTKEY
SINGLE CYLINDER LEVERSET
BRUSHED NICKLE FINISH. (TYP)
DRYER VENT
(VENT
THROUGH
ROOF "VTR")
33"X22"X8" DOUBLE
BASIN STAINLESS
STEEL SINK
A/C EQUP.
STACKABLE
WASHER
AND DRYER
S
WALL MIRROR
RECESSED 3-
SHELF, MIRRORED
MEDICINE CABINET
36"H COUNTER WITH
SOLID SURFACE TOP
AND 18" OVAL OR
INTEGRATED VANITY
SINK
WIRE SHELVING.
CLOSETMAID
SHELF OR SIMILAR.
TOILET PAPER DISPENSER
TOWEL RING
TOWEL BAR
GRAB BAR
WIRE SHELVING.
CLOSETMAID
SHELF OR SIMILAR.
(TYP)
WALL MIRROR
RECESSED 3-SHELF,
MIRRORED
MEDICINE CABINET
36"H COUNTER WITH
SOLID SURFACE TOP
AND INTEGRATED
VANITY SINK
TOILET PAPER
DISPENSER
TOWEL RING
TOWEL BAR
30" OVER THE
RANGE MICRO
FORMICA COUNTERTOP WITH
INTEGRATED 4" BACKSPLASH
30" SMOOTH-TOP, FREESTANDING
ELECTRIC RANGE W/OVEN
36 IN. X 80 IN. RIGHT-HAND
INSWING 1/2-LITE CLEAR VENTED
PRIMED FIBERGLASS SMOOTH
PREHUNG REAR DOOR ON 6-9/16 IN.
SINGLE HUNG
WINDOW, COLONIAL,
WHITE VINYL, LOW-E,
AND ARGON FILLED.
(TYP)
36"X80" LEFT-
HAND INSWING
FAN-LITE CLEAR 4-
PANEL
FIBERGLASS
SMOOTH PREHUNG
FRONT DOOR
10'-0"x6'-0" SLOPPED
CONCRETE SLAB
SAME LEVEL FOR
ROLL IN
ACCESSIBILITY
WALK-IN TUB
RECESSED NICHE
x x
HOSE BIB LOCATION
T.B.D BY OWNER
HOSE BIB.
LOCATION T.B.D
BY OWNER
HOSE BIB. LOCATION T.B.D BY OWNER
HOSE BIB. LOCATION
T.B.D BY OWNER
LEGEND
E.E.R.O INDICATES EMERGENCY ESCAPE
AND RESCUE OPENING.
A.D. INDICATES HANDICAP ACCESSIBLE
DOORWAY.
FLOOR PLAN NOTES
1.U.N.O ALL EXTERIOR CMU WALLS ARE DRAWN AT: 8"
2.U.N.O ALL INTERIOR FRAMED WALLS ARE DRAWN AT: 4"
3.ALL EXTERIOR WALLS, LESS OPENINGS, ARE TO BE CONSIDERED
SHEAR WALL, ALL ROUGH OPENING WINDOW SIZES MUST BE
VERIFIED BY WINDOW CONTRACTOR PRIOR TO CONSTRUCTION, SEE
STRUCTURAL SPECIFICATIONS FOR MATERIAL TYPE.
4.WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE
THAN 72" ABOVE FINISHED GRADE OPENING OF THE WINDOW SHALL
BE A MINIMUM OF 24" ABOVE THE FINISHED FLOOR OF THE ROOM IN
WHICH IT IS LOCATED.
5. FLOORING: WATERPROOF VINYL PLANK THROUGHOUT.
BATHROOMS: WATERPROOF VINYL PLANK. ROLL-IN SHOWER:
CERAMIC TILE
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
A-102
25-14622
F
IR
S T
L E
V E
L F
L O
O R
P L A
N
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
3/8" = 1'-0"2 FIRST LEVEL FLOOR PLAN
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 4
ROOF LEGEND
DENOTES SINGLE OFF-RIDGE VENT
A-301
5" / 1'-0"5" / 1'-0"
A-301
1' - 0"1' - 0"
RIDGE
HIP
HIP
HIPHIP
VENTED ALUMINUM SOFFIT
ZONE 2
ZONE 1
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
A-103
25-14622
R O
O F
P L A
N
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
3/8" = 1'-0"1 ROOF PLAN
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 5
FIRST LEVEL
0"
FIRST LEVEL T.O.P.
8' - 0"
A-301
5"
1'-0"
5"
1'-0"
SHINGLE ROOF
STUCCO WITH SHERWIN
WILLIAMS MULTI-PURPOSE
INT/EXT LATEX PRIMER AND
SHERWIN WILLIAM
SUPERPAINT OR SIMILAR.
COLOR: TBD.
PRECAST WINDOW SILL
36"X80" LEFT-HAND INSWING FAN-
LITE CLEAR 4-PANEL FIBERGLASS
SMOOTH PREHUNG FRONT DOOR
PEEPHOLE VIEWER.
MODEL DS238
KWIKSET TUSTIN
SMARTKEY SINGLE
CYLINDER LEVERSET AND
DEADBOLT COMBO PACK
OR SIMILAR. BRUSHED
NICKLE FINISH.
SINGLE HUNG
WINDOW, COLONIAL,
WHITE VINYL, LOW-E,
AND ARGON FILLED.
2" ALUMINUM DRIP EDGE
ALUMINUM WOODGRAIN FASCIA
EXTERIOR CEILING WITH
SHERWIN WILLIAMS MULTI-
PURPOSE INT/EXT LATEX PRIMER
AND SHERWIN WILLIAM
SUPERPAINT OR SIMILAR.
COLOR: TBD.
MOTION SECURITY
FLOODLIGHTS
HOSE BIB
LOCATION T.B.D BY
OWNER
FIRST LEVEL
0"
FIRST LEVEL T.O.P.
8' - 0"
A-301
5"
1'-0"
5"
1'-0"
STUCCO WITH SHERWIN
WILLIAMS MULTI-PURPOSE
INT/EXT LATEX PRIMER AND
SHERWIN WILLIAM
SUPERPAINT OR SIMILAR.
COLOR: TBD.
PRECAST WINDOW SILL
SHINGLE ROOF
KWIKSET TUSTIN SMARTKEY
SINGLE CYLINDER LEVERSET AND
DEADBOLT COMBO PACK OR
SIMILAR. BRUSHED NICKLE FINISH.
36 IN. X 80 IN. RIGHT-HAND
INSWING 1/2-LITE CLEAR VENTED
PRIMED FIBERGLASS SMOOTH
PREHUNG REAR DOOR ON 6-9/16 IN.
SINGLE HUNG
WINDOW, COLONIAL,
WHITE VINYL, LOW-E,
AND ARGON FILLED.
2" ALUMINUM DRIP EDGE
ALUMINUM WOODGRAIN FASCIA
MOTION SECURITY
FLOODLIGHTS
HOSE BIB
LOCATION T.B.D BY
OWNER
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
A-201
25-14622
E X
T E
R
IO
R E
L E
V A
T
IO
N S
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
3/8" = 1'-0"1 BUILDING ELEVATION - FRONT
3/8" = 1'-0"2 BUILDING ELEVATION - REAR
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 6
FIRST LEVEL
0"
FIRST LEVEL T.O.P.
8' - 0"
5"
1'-0"
5"
1'-0"
A-301
2" ALUMINUM DRIP EDGE
ALUMINUM WOODGRAIN FASCIA
STUCCO WITH SHERWIN
WILLIAMS MULTI-PURPOSE
INT/EXT LATEX PRIMER AND
SHERWIN WILLIAM
SUPERPAINT OR SIMILAR.
COLOR: TBD.
CONCRETE SLAB FOR A/C MACHINE
SHINGLE ROOF
MOTION SECURITY
FLOODLIGHTS
HOSE BIB
LOCATION T.B.D BY
OWNER
FIRST LEVEL
0"
FIRST LEVEL T.O.P.
8' - 0"
5"
1'-0"
5"
1'-0"
A-301
2" ALUMINUM DRIP EDGE
ALUMINUM WOODGRAIN FASCIA
STUCCO WITH SHERWIN
WILLIAMS MULTI-PURPOSE
INT/EXT LATEX PRIMER AND
SHERWIN WILLIAM
SUPERPAINT OR SIMILAR.
COLOR: TBD.
SHINGLE ROOF
MOTION SECURITY
FLOODLIGHTS
HOSE BIB
LOCATION T.B.D BY
OWNER
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
A-202
25-14622
E X
T E
R
IO
R E
L E
V A
T
IO
N S
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
3/8" = 1'-0"1 BUILDING ELEVATION - RIGHT
3/8" = 1'-0"3 BUILDING ELEVATION - LEFT
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 7
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
A-203
25-14622
E X
T E
R
IO
R I S
O M
E T
R
IC
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
1 ISOMETRIC FRONT
2 ISOMETRIC RIGHT
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 8
8" MASONRY REINF. IN SOLID
GROUTED CELL PER STRUCTURALS
CONCRETE SLAB
P.T. FURRING STRIP
1/2" GYPSUM LIGHTWEIGHT
WALLBOARD W/KNOCKDOWN
TEXTURE
GRADE
3 1/4" BASE @ FINISHED
FLOOR
3/4" P.T. NAILER
W/ 1/2" GYPSUM BOARD
5/8" GYPSUM OR
1/2" SAG-RESISTANT
GYPSUM BOARD
CONT. SOFFIT
TRUSS CONNECTION PER
STRUCTURALS
2x SUB FASCIA
SEE ELEVATIONS
TOP OF BEARING
0'-0"
FINISH FLOOR
6 MIL. VISQUEEN
VAPOR BARRIER
TAPED OVER
COMPACTED FILL. SEE
STRUCTURAL FOR
ADDITIONAL
INFORMATION
BATT INSULATION ABOVE THE
CELING
PRE-ENGINEERED TRUSS
SEE DETAILS FOR
WINDOW OR DOOR
APPLICATION
SEE STRUCTURALS FOR
FOUNDATION INFORMATION
1/2" PCBP (2 COAT)
1/2" PCBP (2 COAT)
COMPOSITE SHINGLES
R-4.1 INSUL.
FI-FOIL
BAFFLE IF BATT INSULATION IS USED
ALUMINUM WOODGRAIN FASCIA
2" ALUMINUM DRIP EDGE
FIRST LEVEL
0"
FIRST LEVEL T.O.P.
8' - 0"
GREAT ROOM
8' - 0" CLG
KIT/DINING
8' - 0" CLG
PORCH
8' - 0" CLG
EXTERIOR DRYWALL
KNOCK DOWN TEXTURE
SLOPED CONCRETE SLAB
SLOPED CONCRETE SLAB
MOTION SECURITY
FLOODLIGHTS
R-30 FIBERGLASS
BATT INSULATION
TRUSSES. SEE
STRUCTURAL DRAWINGS
LOWER CABINET W/ONE
DRAWER STACK
FORMICA COUNTERTOP
WITH INTEGRATED 4"
BACKSPLASH
30" HGT. UPPER CABINET
9/16" x3-1/4". PRIMED
FINGER JOINTED WOOD
BASEBOARD MOLDING OR
SIMILAR
11/16" x 2-1/4". PRIMED
FINGER JOINTED DOOR
AND WINDOW CASING
MOLDING OR SIMILAR
FIRST LEVEL
0"
FIRST LEVEL T.O.P.
8' - 0"
BATH
8' - 0" CLG
GREAT ROOM
8' - 0" CLG
A/C
8' - 0" CLG
LINEN
8' - 0" CLG
MASTER BEDROOM
8' - 0" CLG
R-30 FIBERGLASS
BATT INSULATION
TRUSSES. SEE
STRUCTURAL DRAWINGS
9/16" x3-1/4". PRIMED
FINGER JOINTED WOOD
BASEBOARD MOLDING OR
SIMILAR
11/16" x 2-1/4". PRIMED
FINGER JOINTED DOOR
AND WINDOW CASING
MOLDING OR SIMILAR
THREE BULB LED FIXTURE
24"x32" WALL MIRROR
1 HAN
WALK-IN TUB
RECESSED NICHE
HOSE BIB LOCATION T.B.D
BY OWNER
A-301
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
A-301
25-14622
B U
IL
D
IN
G
S E
C T
IO
N
S
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
3/8" = 1'-0"2 BUILDING SECTION A
3/8" = 1'-0"3 BUILDING SECTION B
Scale
File Name
Section
3/4" = 1'-0"
S1MX-01_MOD
1 STORY WALL SECTION
MONO FOUNDATION
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 9
(2) COAT DECORATIVE STUCCO FINISH,
INSTALL PER ASTM C926
SOFFIT
NOTE: EXTEND STUCCO
SYSTEM ABOVE SOFFIT
DRIP EDGE
SUB FASCIA
ALUMINUM FASCIA CAP,
WHEN APPLICABLE
SUGGESTED, BUT NOT REQUIRED :
OPTIONAL "J" CHANNEL STUCCO
ACCESSORY, THE USE OF 1x P.T.
LUMBER IS ACCEPTABLE I.L.O.
ACCESSORY. THIS MUST BE
PRE-APPROVED BY BUILDER.
OR
INSTALLER MAY TERMINATE WITHOUT
THE USE OF AN ACCESSORY.
EXTENDED 1/2"
FOR DRIP
1. FOLD INWARD AT POINT "A" 1. FOLD INWARD AT POINT 'A'
2. CREASE AT POINT 'B'
FOLD AT 45°
1 2
1. FOLD INWARD AT POINT 'A'
2. CREASE AT POINT 'B'
3. CREASE AT POINT 'C'
1. FOLD INWARD AT POINT 'A'
2. CREASE AT POINT 'B'
3. CREASE AT POINT 'C'
4. FOLD POINT 'C' OVER POINT 'B' TILL
POINT 'C' TOUCHES BOTTOM FLANGE
3 4
FOLD AT 77°
77°
BOTTOM FLANGE
WATER TIGHT SEAL,
FOLD, DO NOT CUT
M
IN
5" M
IN.
110°
45°
A A
A A
B
B C
FELT UNDERLAYMENT
DRIP EDGE, OVERLAP 3", EXTEND 1/2"
BELOW SHEATHING, MECHANICALLY
FASTEN 4" o.c. MAX.
NOTE:
INSTALL KICK OUT FLASHING AT BOTTOM
OF ROOF AND WALL INTERSECTION
7/8" PCBP (3 COAT)
LAP LAYERS OF BUILDING WRAP OVER NAILING
FLANGE, STOP WRB APPROX. 1 1/2" ABOVE SHINGLES
LATH
(2) LAYERS WRB
ROOF/WALL SCREED
5"X5" WALL FLASHING
SHIN
GLE
ROOFIN
G
FA
SCIA W
RAP LA
P
UNDER
LA
YMEN
T
KICK-OUT
FLASHING (SEE
DETAIL)
L A P
U
D E R
L A Y M
E N
T
110°
WATER TIGHT SEAL
(BEND OR SOLDER, DO NOT CUT)
5" M
IN
M
IN
8" MIN.
1X4 OR DOOR TRIM
MOLDING CUT TO
ENCASE OPENING
BOTTOM CHORD
TRUSS 1/2" GYPSUM
BOARD OVER 23/32"
WOOD PANEL LID
22" MIN. WIDTH
30" MIN. LENGTH
M
IN
INSULATION DAMS
(7/16" MIN. WOOD
PANELS)
SELF ADHERING FLASHING
TAPE, BUILDER PRE-APPROVED,
MUST BE INSTALLED OVER WRB
& 60 MINUTE PAPER BEHIND
VERTICAL CONTROL JOINT
WHEN NAILS ARE USED.
VERTICAL CONTROL JOINT TO
BE PLACED FIRST AND THEN
LATH TO OVERLAP FLANGE
ELEVATION VIEW
VERTICAL CONTROL
JOINT CONT.
FOR PURPOSES OF HOLDING
ACCESSORY IN PLACE, LOOSE NAILS
MAY BE INSTALLED IN CENTER OF
OVAL HOLES. NAILS SHALL BE
LOOSE AND SHALL NOT BE CLOSER
THEN 36" O.C. AND SHALL BE
INSTALLED ON ONE SIDE OF
ACCESSORY, NOT STAGGERED.
MID-WALL WEEP SCREED
DO NOT SEAL WEEP
NOTE:
TRIM NAILING FLANGE ON HORIZONTAL
WEEP SCREED AND BUTTERFLY CUT
VERTICAL CONTROL JOINT TO BE PLACED
OVER WEEP SCREED. WEEP SCREED AND
CONTROL JOINT OUTER SURFACES SHOULD
BE FLUSH WITH NO BUG RUNS OR
PROTRUSIONS AND CONTROL JOINT
SHOULD DRAIN TO WEEP SCREED.
ONE-PIECE VERTICAL
"M" TYPE CONTROL
JOINT
LATH SHALL NOT BE
CONTINUOUS
THROUGH CONTROL
JOINTSTIE ACCESSORY TO LATH
FLASHING TAPE, BUILDER PRE-
APPROVED, WHEN NAILS ARE
USED TO HOLD ACCESSORY IN PLACE
(EXTEND 3" PAST WEEP SCREED)
WALL SHEATHING PER PLAN
W.R.B. & 60 MINUTE PAPER
(DO NOT DAMAGE WATER
RESISTANT BARRIER)
(3) COAT STUCCO 7/8" MIN.
THICKNESS, INSTALL PER ASTM
C926, C1063
METAL LATH (DO NOT DAMAGE
METAL LATH)
NOTE: WATER RESISTANT BARRIER AND METAL LATH MUST
LAP TO PROMOTED PROPER DRAINAGE
NOTE:
CONTROL JOINTS SHALL BE PLACED PER ASTM
REQUIREMENTS.
FLASHING TAPE IS NOT REQUIRED IF 60 MINUTE
PAPER AND WRB ARE NOT DAMAGED BEHIND THE
STUCCO ACCESSORIES.
IF WRB & 60 MINUTE PAPER IS DAMAGED THAN
SELF ADHERED FLASHING TAPE IS REQUIRED
BEHIND STUCCO ACCESSORIES.
PLAN VIEW
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
AD-01
25-14622
A R
Q U
IT
E
C T
U R
A L
D E
T A
IL
S
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
3/4" = 1'-0"
DFRS-01
WALL KICKOUT FLASHING
3/8" = 1'-0"
SOI-01
ATTIC ACCESS AT HOUSE
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
NOT USEDNOT USED
NOT USEDNOT USED
NOT USED
1 1/2" = 1'-0"
DF-XF-01
"M" TYPE CONTROL JOINT
1 1/2" = 1'-0"
SECTION AT SOFFIT - CMU-MOD
Scale
File Name
Section
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 10
8"
6"
6"
6"
CEDAR SHINGLES
VENT OR FLUE PIPE
MASTIC
ROOF JACK
2X6 T&G WOOD DECKING
NAILED TO TIMBER
RAFTERS OR TRUSSES
CEDAR SHINGLES FOR HIGH
WIND RESISTANCE PER ASTM
D3161, OVER 15# FIBERGLASS
ROOFING FELT
NAIL BASE FOR SHINGLES
(PLYWOOD) SCREWED
THROUGH RIGID INSULATION
TO TRUSSES
R-30 RIGID INSULATION (6") IN
TWO OR THREE LAYERS WITH
HORIZONTAL AND VERTICAL
JOINTS STAGGERED
TRUSSES
CEDAR BREATHER LAYER
ICE AND WATER SHIELD
SEE
ELEVATIONS
TOP OF
BEARING
WALL SHEATING
(PREFAB UNTIL TOP BEARING)
WALL SHEATING
(TO BE BUILD IN FIELD)
6"
SHEATING
TRUSS - SEE STRUCT.
SECONDARY
UNDERLAYMENT
CROSS OVER PRIMARY
UNDERLAYMENT TO
THIS POINT
PRIMARY
UNDERLAYMENT
SECONDARY
UNDERLAYMENT
12" STRIPS OF SECONDARY
UNDERLAYMENT
1"
MASTIC BED AT VALLEY
METAL OVERLAP
3"
MIN.
2"
18"
STARTER COURSE
MASTIC BED
(TYPICAL)
PRIMARY
UNDERLAYMENT TO
EDGE OF RAKE
CLEATS AT 24" O.C.
24" WIDE COPPER VALLEY IN
10'-0" MAXIMUM LENGTHS AND
1" "V" CRIMP SEE PROFILE
8" WIDE VALLEY FLASHING IN
10'-0" MAXIMUM LENGTHS
8"
12"12"
18" 18"
4"4"
MASTIC UNDER VALLEY
METAL AT EAVE AND
UP UNDER FASCIA
COPPER DRIP EDGE
12" STRIPS OF SECONDARY
UNDERLAYMENT
ROOF
SHEATHING
METAL DRIP
EDGE
SECONDARY
UNDERLAYMENT
(2) ROWS OF SECONDARY
UNDERLAYMENT UP RAKE
CLEATS AT 24" O.C.
METAL
VALLEY
1"
PROFILE
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
AD-02
25-14622
A R
Q U
IT
E
C T
U R
A L
D E
T A
IL
S
R
O O
F
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
Scale
File Name
SectionSection Scale
File Name
SectionScale
File Name
SectionScale
File Name
Section
1 1/2" = 1'-0"
DRS-02
PIPE JACK DETAIL SHINGLE
1" = 1'-0"
SFX-08
SHEATHING FINISH AT ROOF
3/8" = 1'-0"
SRS-01
RIDGE/HIP CAP FLASHING
1 1/2" = 1'-0"
DRS-03
METAL VALLEY FLASHING DETAIL
Scale
File Name
Section
M A
R K
D
A T
E D
E S
C R
IP
T
IO
N
C - 11
DRYWALL
INTERIOR
FINISH
DRYWALL
RETURN
P.T. BUCK,
BACK-CAULKED
(2) COAT STUCCO FINISH, INSTALL PER ASTM
C926, C1063
CONTINUOUS BEAD OF
SEALANT
TOP AND SIDE JAMBS ONLY
WINDOW ASSEMBLY
90° CORNER STUCCO
ACCESSORY
SEALANT/ADHESIVE
BUILDER PRE-APPROVED,
CONTINUOUS BEAD OF
SEALANT BEHIND WINDOW
FRAME AS PER
MANUFACTURER'S SPECS
"V" GROOVE IN
STUCCO 3_
" DEEP
P.T. BUCK
(2) COAT DECORATIVE STUCCO FINISH,
INSTALL PER ASTM C926, C1063
SEALANT/ADHESIVE
BUILDER PRE-APPROVED,
CONTINUOUS BEAD OF
SEALANT BEHIND
WINDOW FRAME AS PER
MANUFACTURER'S SPECS
90° CORNER
STUCCO
ACCESSORY
SEALANT/ADHESIVE BUILDER PRE-APPROVED,
CONTINUOUS BEAD OF SEALANT BEHIND
WINDOW FRAME AS PER MANUFACTURER'S
SPECS
CONTINUOUS BEAD
OF SEALANT
TOP AND SIDE
JAMBS ONLY
"V" GROOVE IN
STUCCO
DRYWALL
INTERIOR FINISH
DRYWALL INTERIOR
FINISH
PRECAST SILL,
STYLE BY BUILDER
(2) COAT DECORATIVE
STUCCO FINISH, INSTALL PER
ASTM C926, C1063
FINISHED SILL
PER PLAN
P.T. BUCK
BACK CAULKED
90° CORNER
STUCCO
ACCESSORY
SLOPED
CONTINUOUS
BEAD OF
SEALANT
"V" GROOVE IN
STUCCO
WINDOW ASSEMBLY
CMU
MIN. 1_
" DEEP
"V" GROOVE IN
STUCCO AROUND
WINDOW.1_
SEPARATION
NOT REQUIRED.
GROOVE TO BE
CAULKED
CMU
(2) COAT
DECORATIVE
STUCCO FINISH,
INSTALL PER
ASTM C926,
C1063
90° CORNER
STUCCO
ACCESSORY
ATTACHED TO
TOP, SIDE &
BOTTOM
SEALANT
DOOR
SWEEP
THRESHOLD
SET THRESHOLD
IN SEALANT
2x STUDS
1/2" GYPSUM WALL BOARD
TRIM
SHIM AS REQUIRED
DOOR FRAME
1/2" GYPSUM WALL BOARD
TRIM
1/2" GYPSUM WALL BOARD
TRIM
DOOR FRAME
TRIM
1/2" GYPSUM WALL BOARD
S E
A L
B
ID
P R
O G
R E
S S
S E
T
N O
T F
O R
C O
N S
T R
U C
T
NOTES SHALL BE BROUGHT
TO THE ATTENTION OF THE
DESIGN PROFESSIONAL FOR
CLARIFICATION PRIOR TO
COMMENCEMENT OF
CONSTRUCTION.
SHEET NUMBER
DATE:
JOB #:
1230 Oakley Seaver Drive, Suite 100 Clermont, Florida 34711
888.850.FFAE (3323)
www.forefront.com
AR102538-CA30900
ISSUE - REVISION LOG
A R C H I T E C T U R E
E N G I N E E R I N G
J O
B N
A M
E
S H
E E
T N
A M
E
C U s e rs
\m ic h e lle g \D o c u m e n ts
\2
-0 -1
H
O U
S
IN
G A
S S
IS
T
A N
C E
P R
O G
R A
M -W
O O
D B
U R
Y R
E S
ID
E
N C
E A
R C
H
R V
T m ic h e lle g
J J B
.r v t
AD-03
25-14622
A R
Q U
IT
E
C T
U R
A L
D E
T A
IL
S
D
O O
R
W
IN
D O
W
H O
U S
IN
G
A S
S
IS
T A
N C
E P
R O
G R
A M
W
O O
D B
U R
R Y
R E
S
ID
E N
C E
N
W E
S T
T
H A
V E
O C
A L A
F
L
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Section
Scale
File Name
Se…