Exhibit B1 Program of Requirements 1.03.pdf

PDF 2 MB Posted

Attached to
General Services Administration (GSA) seeks to lease office and special use warehouse space in Aurora, Colorado
Solicitation number
0CO2475
Issued by

About this file

This document is a Request for Lease Proposals (RLP) issued by the General Services Administration's (GSA) Public Buildings Service Central Office. GSA is seeking to lease approximately 23,000 ABOA square feet of office, special use warehouse, and 24/7 operational center space in Aurora, Colorado. The space must not be co-located with hazardous materials and must accommodate canine service dogs. Additional requirements include 31 surface parking spaces, 2,000-3,000 USF of warehouse storage, EV charging stations, and visitor parking for local hiring events. The offered space must meet fire safety, accessibility, seismic, and sustainability standards. Offers are due by August 26, 2022 at 5:00 PM MDT, and the estimated occupancy date is Q2 2026. Interested parties must submit offers electronically through the Requirement Specific Acquisition Platform (RSAP).

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Version 1.03

Prepared By Enterprise Support

Program of Requirements Tools for leasehold improvements at TSA locations iiTSA Program of Requirements1.03

Table of Contents

1.0 INTRODUCTION

1.1 Background

1.2 Purpose

1.3 Application

1.4 General Site Criteria

1.4.1 Site Criteria

1.4.2 Security Considerations

1.4.3 Office Support Spaces

1.4.4 Parking

1.4.5 Building Signage

2.0 ARCHITECTURAL SPECIFICATIONS

2.1Partitions ..................................................... 4
2.1.1PartitionTypes .............................................4

2.1.2 Partition Criteria

2.1.3 Partition Notes

2.2 Doors, Frames and Hardware

2.2.1 Door Types

2.2.2 Door Criteria

2.2.3 Frame Types

2.2.4 Frame Criteria

2.2.5 Hardware Types

2.2.6 Hardware Criteria

2.2.7 Door Frame and Hardware Notes

2.3 Ceilings

2.3.1 Ceiling Types

2.3.2 Ceiling Criteria

2.3.3 Ceiling Notes

2.4 Flooring

2.4.1 Flooring Types

2.4.2 Flooring Criteria

2.4.3 Flooring Notes

2.5 Finishes

2.5.1 Wall Finish Types

2.5.2 Wall Finish Criteria

2.5.3 Wall Base Criteria

2.6 Millwork

2.6.1 Millwork Types

2.6.2 Millwork Criteria

2.7 HVAC

2.7.1 HVAC Types

2.7.2 HVAC Criteria

2.7.3 HVAC Notes

2.8 Plumbing

2.8.1 Plumbing Types

2.8.2 Plumbing Criteria

2.8.3 Plumbing Notes

2.9Lighting ..................................................... 12
2.9.1LightingTypes ............................................12

2.9.2 Lighting Criteria

2.9.3 Lighting Notes

2.10 Electrical and Telecommunications

2.10.1 Electrical and Telecom Types

2.10.2 Electrical and Telecom Criteria

2.10.3 Electrical and Telecom Notes

2.11 IT Security

2.11.1 Telecommunications Room

2.11.2 Telecommunications Cabinet

2.12 Equipment

2.12.1 Equipment Types

2.12.2 Equipment Notes

3.0 DELIVERABLES

3.1 Dissemination of Sensitive Documents

3.1.1 Sheet File Security Imprint

3.1.2 Cover Sheet Security Imprint

3.1.3 Deliverable File Formats

3.1.4 Third Party Software Criteria

3.1.5 Design Intent Drawing

3.1.6 Electronic Submittals

3.1.7 Quantities

3.1.8 Email Transmittals

3.1.9 Space Plans

3.1.10 Construction Documents

3.1.11 As-Built Drawings

3.1.12 Cost Estimates

iiiTSA Program of Requirements1.03

4.0 SPACE TYPICALS

CH1 - Component Head Private Office (240 SF)

P2 - Private Office (120 SF)

P3 - Private Office (100 SF)

W1 - Workstation (48 SF)

W2 - Workstation (36 SF)

FR1 - File Room (120 SF)

BR1 - Breakroom (210 SF)

BR2 - Breakroom (170 SF)

CP1 - Copy Room (120 SF)

LAN1 - IT/LAN/Server/Communications Closet (150

SF)

REC1 - Reception Area - Staffed (200 SF)

SR1 - Storage Room (100 SF)

HUD1 - Huddle Room (100 SF)

PRV1 - Privacy Room (80 SF)

CR1 - Conference Room - Large (480 SF)

MPR2 - Multipurpose Room -Small (600 SF)

TBR1 - TSO Breakroom (SF Varies)

OLC1 - On-Line Learning Center (420 SF)

LTR1 - Lecture Training (500 SF)

ATL1 - ATLAS Support Space (200 SF)

COC1 - Coordination Center - Large (700 SF)

OS1 - Operational Storage (Min 150 SF/Max 10,000

SF)

TSSE1 - TSSE Support Space (180 SF)

CSS1 - Canine Support Space (1500 SF)

LCH1 - Local Hiring/Assessment Center - Large (860

SF)

5.0 ARCHITECTURAL MATRIX

6.0 GUIDELINES FOR SAFETY, HEALTH AND FIRE

PROTECTION REQUIREMENTS

6.1 General

6.2RoutesofEgress ........................................ 49
6.2.1BasicRequirements..................................49

6.2.2 Exit Routes

6.2.3 Exit Discharge

6.2.4 Exit Door Access

6.2.5 Door Hinges

6.2.6 Exit Route Capacity

6.2.7 Height and Width Requirements

6.2.8 Outdoor Exit Routes

6.3 Life Safety

6.3.1 Exit Signs

6.3.2 Emergency Lighting

6.3.3 Manual Fire Alarm Boxes

6.3.4 Smoke Detectors

6.3.5 Audible and Visible Signals

6.3.6 Fire Sprinkler Protection System

6.4 Breakrooms

6.5 Asbestos

6.6 Permissible Exposure Limit (PEL)

6.7 Requirements for Building/Facility Owners

6.7.1 Notification Requirements

6.7.2 Signs and Labels

6.7.3 Records Retention

6.8 Competent Person

6.8.1 Duties

6.8.2 Training

6.9ExposureMonitoring ................................ 53
6.9.1InitialExposureAssessment.....................53

6.9.2 Negative Initial Exposure Assessment

6.9.3 Periodic Monitoring

6.10 Methods of Compliance

6.10.1 Requirements Applying to All Jobs

6.10.2 Requirements Applying to Specific Classes

of Asbestos Work

6.11 Lead Based Paint

6.11.1 Summary of Findings

6.12 Definitions

7.0 GUIDELINES FOR STRUCTURED CABLING

SYSTEMS

7.1 Introduction

7.1.1 Scope

7.1.2 Structured Cabling Systems

7.1.3 Telecommunications Wiring System

Subsystems

7.1.4SitePreparationGuidelines.....................59
7.1.4.1 GeneralInformation........................................59

ivTSA Program of Requirements1.03

7.1.4.2 Specifications

7.2WorkstationEquipmentSubsystem .......... 59
7.2.1Definition..................................................59
7.2.2GeneralInformation.................................59
7.2.2.1 EquipmentSpecifications.................................59

7.2.2.2 UTP Patch Cords

7.3 Horizontal Subsystem

7.3.1 Definition

7.3.2 General Information

7.4MainDistributionFrame(MDF)and
IntermediateDistributionFrame
(IDF)EquipmentSubsystemand
TelecommunicationsClosets ..................... 61
7.4.1Definition..................................................61
7.4.1.1 Telecommunications–MDF–MainDistribution

Frame

7.4.1.2 Telecommunications–IDF–Intermediate
DistributionFrame ...........................................61
7.4.1.3 Recommendedtelecommunicationscloset(MDF
orIDF)sizes ......................................................61

7.4.2 General Information

7.4.3Specifications............................................62
7.4.3.1 FloorLoading(FloorMountCabinets) ...............62

7.4.3.2 Provisioning

7.5 In-Building Backbone Subsystem

7.5.1 Definition

7.5.2 General Information

7.5.3 Site Selection

7.5.4 Floor Loading (Floor Mount Cabinets

7.5.5 Water Infiltration

7.5.6 Heating, Venting and Air Conditioning

(HVAC)

7.5.7 Electromagnetic Interference

7.5.8 Vibration

7.5.9 Size

7.5.10 Provisioning

7.5.11 Campus Backbone System

7.5.12 Definition

7.6InstallationandOngoingMaintenance ... 64
7.6.1PhysicalRouting .........................................65
7.6.1.1 SeparationfromSourcesofElectromagnetic

Interference (EMI)

7.6.1.2 UTP Splices and Bridge Taps

7.6.1.3 UTP Cable Bends

7.6.1.4 Patch Cords

7.6.2 Conduit

7.6.2.1 General

7.6.2.2 Types of Conduit

7.6.2.3 Use of Conduit

7.6.2.4 Minimum Requirements

7.6.2.5 Bends

7.6.2.6 Fish-tape or Pull-cord

7.6.2.7 Conduit Run

7.6.2.8 Conduit Termination

7.6.3PhysicalMediaSpecifications..................67
7.6.3.1 TechnicalReference.........................................67

7.6.3.2 Length

7.6.3.3 Construction

7.6.3.4 Twisted Pairs

7.6.3.5 Cable Diameter

7.6.3.6 Breaking Strength

7.6.3.7 Bending Radius

7.6.3.8 UTP Polarization

7.6.4TransmissionCharacteristics.....................67
7.6.4.1 TechnicalReference.........................................67

7.6.4.2 DC Resistance

7.6.4.3 DC Resistance Unbalance

7.6.4.4 Mutual Capacitance

7.6.4.5 Capacitance Unbalance: Pair to Ground

7.6.4.6 CharacteristicImpedanceandStructuralReturn
Loss(SRL) .........................................................68
7.6.5Data-RelatedUTPConnectingHardware:
PhysicalSpecifications..............................68

7.6.5.1 Technical Reference

7.6.5.2 Overall Construction

7.6.5.3 RJ-45 Construction

7.6.6 Fiber Optic Cabling: Physical Specifications

7.6.6.1 Technical References

7.6.6.2 Construction

7.6.6.3 Quantity Locations with one MDF and one or

more IDF

7.6.7FiberOpticCabling:Transmission
Specifications............................................68

7.6.7.1 Technical Reference

7.6.7.2 Transmission Characteristics

7.6.8 Fiber Optic Connecting Hardware: Physical

Specifications vTSA Program of Requirements1.03

7.6.8.1 Technical Reference

7.6.8.2 Construction

7.6.9FiberOpticConnectingHardware:
TransmissionCharacteristics ......................69

7.6.9.1 Technical Reference

7.6.9.2 Attenuation

7.7AcceptanceTesting ................................... 69
7.7.1Definition ...................................................69

7.7.2 General

7.7.3UnshieldedTwistedPairTesting ................69
7.7.3.1 VisualInspection ...............................................69

7.7.3.2 Certification Requirements

7.7.4 Fiber Optic Circuits

7.8 Labeling, Cable Management and

Administration

7.8.1 Introduction

7.8.2 Labeling

7.8.2.1 Data Jack Labeling

7.8.2.2 Patch Panel Designation

7.8.2.3 Patch Cable Labeling

7.8.2.4 Patch Panel & Port Designation

7.8.2.5 Switch, Switch Blade & Port Designation

7.8.3 Cable Standards

7.8.4 Cable Management

7.8.4.1 Cable Management Figures

7.9 Firestopping

7.9.1 Definition

7.9.2 General information

7.9.3 Requirements

7.9.4 Specifications

7.9.5 Approved Material Types

7.9.6 Selection Criteria

7.10TelecommunicationsBondingand
GroundingRequirements......................... 73
7.11TSACabinetSpecifications ....................... 74
7.11.1CabinetElectricalSpecifications...............74

7.11.2 Cabinet Size Specifications - Open Racks ...75

7.11.3 Cable Management for Open Racks

7.11.4 Cabinet Sizes Specifications - Wall Mount .76

7.11.5 Cabinet Sizes Specification - Closed Racks .76

7.11.6 Cabinet Air Conditioning Requirements

7.12 Glossary

7.13 Acronyms

7.14InformationSources/ReferencedDocuments
&Acknowledgments ................................. 79

8.0 ABBREVIATIONS LIST

9.0 VERSION HISTORY

1TSA Program of Requirements1.03

1.0 Introduction

1.1 Background

TheProgramofRequirements(POR)isa
comprehensivedocumentthatprovidesconstruction
specificationsforallTSAlocationshousingand/or
supportingFederalSecurityDirectors(FSD),their
staffandtheTSOworkforce.Informationprovidedin

this document is the result of requirements provided

byTheOfficeofAcquisitionProgramManagement
(OAPM),OfficeoftheChiefInformationOfficer
(OCIO),theOfficeofPhysicalSecurityandtheField
ServicesBranch(FSB),OccupationalSafety,Health
andEnvironment(OSHE).
Formoredetailedinformationandguidance
regardingtheallocationofspace,amountsof
appropriatespacefordifferentTSAfunctions,leasing
andrenovationofspace,purchaseandinstallationof
furniture,parkingofofficialgovernmentvehiclesand

related real estate space and leasing services, refer to the following tools and documents, all available on

theFSB,RealEstateManagementDivision’s(REMD)
Sharepointsite:

• TSA Workplace Standards

• TSA Management Directive No. 200.12

1.2 Purpose

The purpose of preparing this POR is to establish general guidelines that communicate design objectives and criteria to GSA, Lessors, architects, designers and engineers managing and developing construction projects for TSA. Every effort should be made to apply these build-out standards across

theboardtoensureconsistencyinFSDofficesand
supportspaces.Whereminorrenovationswillbe

performed, the standards published in this document should be followed as closely as possible.

Standards and specifications provided throughout this document are to be used as guidelines for

designandconstruction.Spacelayoutscanvary
orrequiremodificationwhenaffectedbysite
conditionsthatmayincludebutarenotlimited
toexistingarchitecturalandstructuralelements,

life safety egress code requirements and security considerations.

Where feasible, building standards and designs will also seek to comply with the revised Guiding Principles for Sustainable Federal Buildings, issued by the Council on Environmental Quality in 2016.

This POR does not apply to passenger checkpoints, checked baggage screening areas or headquarters

spaces.Pleasenotethatalltheconstruction
specifications,includingallarchitectural,
telecommunications,securityandsafety

requirements for checkpoint areas and baggage

screeningareasarecoordinatedwiththerespective
TSAProgramOffices.

2TSA Program of Requirements1.03

1.3 Application

Leasedspacethatisraw(openwithnowalls)
orconfiguredforotherthanofficeuseorwhere
modificationsareneededtoaccommodatethe
requirednumbersofstaffandsupportspaces,will
bedesignedorreconfiguredandconstructedto

conform, inasmuch as possible, to the standards

outlinedinthisPOR.Thelevelofeffortisalso
contingentupontheavailabilityoffunding.

Leased space accepted in “as-is” condition may or may not comply with the standards and guidelines

outlinedinthisPOR.Spaceisacceptedin“as-is”
conditionwhenithasbeendeterminedthatstaff

and support spaces can be accommodated in the space without major construction/renovations.

Minor improvements may be made such as paint and

carpetreplacement.Priortooccupancy,REMDwill
workwithOCIOandtheOfficeofPhysicalSecurity
tocoordinatetheinstallationoftelecommunications

and security enhancements required to make the space operational and secure.

Whenrenovatingexistingleasedspace,requested
modificationsshould,inasmuchaspossible,conform
tothestandardsinthePOR.Thelevelofeffortis
alsocontingentupontheavailabilityoffunding.

1.4 General Site Criteria

1.4.1 Site Criteria

CriteriahavebeenestablishedforallTSAlocationsto
belocatedatornearairportfacilities.Requirements
wereestablishedbasedonoperationalneedsdefined
byOSOandtheOfficeofPhysicalSecurity.Thetable

below summarizes the basic requirements to be

followed,inasmuchaspossible,forFSDofficesand
supportspaces.Specificsafetyand,detailedsecurity
requirementscanbefoundintheAppendixofthis

document.

1.4.2 SecurityConsiderations
ConsiderationsforselectionofTSAOfficespace
shouldbeanintegralpartoftheinitialevaluation
processofamarketsurvey.Effectivesiteselection
canenhancesecurityofanofficeeliminatingthe
needforintricateengineeringsolutions.Placing
greateremphasisonthebuilding’soperating
efficiencyandperformanceattheinitialprojectstage

can greatly reduce total life-cycle cost.

1.4.3 Office Support Spaces

• TSAadministrativeofficesshouldnotbelocated
inwindowedspacethatisadjacenttooutsidefire

escapes, ledges or mezzanines.

• TSAadministrativeofficesshouldbelocatedin
contiguousspaceononefloor,whenavailable.

• Where possible, TSA administrative offices and support spaces should not be located on the top or ground levels of any building.

• In general, office spaces should be placed and glazed such that personnel cannot be seen from uncontrolled public areas. Preferably these offices should face courtyards, interior spaces or controlled areas.

• TSA offices should not be collocated in buildings or areas that handle, store, or ship Hazardous Materials (HAZMAT).

• TSA offices shall not be collocated in any facility where non-TSA personnel require daily access or emergency egress through TSA spaces.

1.4.4 Parking

• Security requirements for parking areas for

officialvehicleswilldependonlocalconditions.
Allparkingforofficialvehiclesshouldbeinclose
proximitytoselectedfacilities.
• Lightingfortheparkingareawilldependon
thelocalconditions.However,adequatelighting

is needed for surveillance and employee safety purposes.

1.4.5 Building Signage

• For Operation Security (OPSEC) purposes, signage should be limited to suite numbers only.

Thereshallnotbeanysignagethatdrawsattention
toorpublicizesthelocationsofTSAoperational

units and personnel.

3TSA Program of Requirements1.03

2.0 ArchitecturalSpecifications
Thissectionoutlinesthevariousarchitectural
specificationsthatarecommonthroughoutTSA
designandconstructionprojects.Theseexamples

are meant to be used purely as a reference, and the final space size and configuration may vary from what is shown here.

The specifications outlined in this section are as follows:

Partitions Doors, Frames and Hardware Ceilings Flooring Finishes Millwork

HVAC

Plumbing Lighting

ElectricalandTelecommunications
ITSecurityConsiderations

Equipment

4TSA Program of Requirements1.03

2.1.1 Partition Types

See table below

2.1.2 PartitionCriteria
Allstandardwallsaretobedesignedfordeflection
nottoexceedL/240oftheheightwhensubjectedto
theminimumpositiveandnegativepressureof5psf
fortypicalpartitions.
• Wallboard:Gypsumwallboardtobe5/8”.
Individualconditionswilldictateneedforfire-rated,

water- resistant or other special wallboard. Verify with A/E. Metal Studs: ASTM C645 roll formed galvanized steel, 25 gauge minimum; spacing 16” on center and size as recommended by the wallboard manufacturer for the wall system and height required.

• SoundAttenuationBatt:Provideacoustical
insulationtothethicknessrecommendedby

manufacturer for the thickness of wall to achieve recommended minimum STC rating of 45.

• All openings in the perimeter walls or interior

partitionsmustbecoveredwith13gaugeexpanded
steelmesh,firmlyanchoredtothewallstudsinside

the secured area. The area of any single opening should not exceed 100 square inches.

2.1.3 Partition Notes

• Installfire-ratedsupplementaryframing,
blockingandbracingatterminationsingypsum
boardassembliestosupportfixtures,equipment,

furnishings, etc. Including wall-hung cabinets in

BreakRoomsandmarkerboardsand/ortelevision/
monitorinConferenceRoomsandCoordination

Center.

• Provide ¾” plywood painted with a light colored

fire-retardantpaintonaminimumof2wallsat18”
abovefinishedfloorandtoaheightof8’inthe
CommunicationsRoom.See“7.4.3.2 Provisioning”

on page 62.

• Provide acoustical sealant at base, head, perimeter and all openings for all sound-rated partitions.

2.1 Partitions

2.1 Partitions

PartitionTypes
Type Description Application(Room)
PT-1 Floortoceilingpartition,metalstudswithgypsumwallboard

both sides

• Standard Offices

• Pantry

• Copy Room

• Local Hiring Center

PT-2 Slab-to-slabpartition,metalstudswithgypsumwallboardboth
sideswithsoundattenuationbatting(minSTC45)
• FSD&orSESOffice
• ConferenceRooms
• Multi-purposeRooms
• CoordinationCenter

• Canine Support Space

• FIOOffice
• TrainingRooms
• TSOBreakRooms
• TeamRooms
• PrivacyRooms

PT-3 Slab-to-slab partition, metal studs with gypsum wallboard both sides

• WaitingArea
• SecureFileRoom

• Secured Storage

• ATLAS Support Space

• Operational Storage

• TSSE-BAO Support Space

• Perimeter partitions

PT-4 Onehourfireratedwall,slab-to-slabsteelstudandgypsum
boardpartition

• Communications Closet

5TSA Program of Requirements1.03

2.2 Doors, Frames and Hardware

steel for openings of 4’-0” and greater. Painted finish.

2.2.5 Hardware Types

• Hinges: Continuous hinges (for level 3 doors)

• Cylinders,Bolts,LocksetsandDeadlocks(for
perimeterdoorsandCommunicationsCloset)

• Push and Pull Silencers, Thresholds, Kick plates (for perimeter doors) and Wall or Floor Stops

2.2.6 Hardware Criteria

• All door hardware and security component

submittalsshouldbesubmittedtoREMDforreview
bytheOfficeofPhysicalSecurity.

• Any hinges that are on the outside of TSA space must be equipped with non-removable pins.

• All hardware must meet ADA accessibility requirements, e.g. latch sets and locksets should have lever handles.

2.2.7 Door Frame and Hardware Notes

• Provide door closers where necessary.

• Provide electronic access controls system.

• Provide electric door strike for any door controlled by the access control system. Provide recessed door contact switch.

• Exitdoorsshouldnotbeequippedwithkey
operationoranytoolstoopenfrominsideof
thebuildingperNFPA101LifeSafetyCode,1997
edition;Paragraph2.15.1.

• For the TSO Break Room and any Training Room used by less than 20 screeners, Medeco locks with keys shall be used.

• For the TSO Break Room and any Training Room used by more than 20 screeners, install EPLEX 5800 or approved equivalent.

2.2 Doors, Frames and Hardware

2.2.1 Door Types

See Door Types Table below

2.2.2 Door Criteria

• Interiorsolidcoreflushwooddoor(Single):
ComplywithNWWDA,I.S.1andAWI1300

Architectural Quality Standards. Premium grade.

5-plyconstructionwithparticleboardorglued-block
core.(Preferred)
• Interiorhollowmetalflushdoor(Single):
ConstructinteriordoorsinaccordancewithANSI/
SDI-100“recommendedSpecificationsforStandard
SteelDoorsandFrames”,GradeIII,extraheavyduty,

model 2, seamless design, minimum 18 gauge outer sheets. (Exception to match existing)

2.2.3 Frame Types

• Hollow Metal - Single Door

2.2.4 Frame Criteria

• HollowMetal:Weldedhollowmetalframe,one
piecerolledsectionwithminimumof16gaugesteel
foropeningslessthan4’-0”inwidthand14gauge

Door Types Type Description DR-1 Typical single, solid core wood door

Size 36” x 84” x 1 3/4” or match existing

DR-2 Fire-rated door to meet local building codes

DR-3 Pre-hung door to be bullet resistant and shall be rated UL 752 SPSA/Level 3 including frame assembly. This door shall be alarmed and equipped with a heavy duty electric strike,

controlledbyareleasebuttonlocatedatthe
receptionistdesk

See Physical Security Program of Requirements for additional information about door and hardware types

6TSA Program of Requirements1.03

2.3 Ceilings

2.3 Ceilings

2.3.1 Ceiling Types

See Ceiling Types Table below

2.3.2 Ceiling Criteria

• Allexistingdamagedceilingtilesand/orgrid
systemaretobereplacedwithnewtilesand
suspensionsystemtomatchexistingsystem.

• For new ceiling installations, use a 2’ x 2’ square system.

• Securesuspensionsystem/wire/rodhangers,
etc.fortheceilingtilesorgypsumboardto

structural members or framing members only.

Never attach the suspended steel framing to the roof decks or to the ducts, pipes and conduits.

• Install edge molding and trim at perimeter of

acousticalceilingwherenecessarytoconcealedges
ofacousticalceilingtiles.
• Applyacousticalsealantinacontinuousribbon
formwhereceilingmeetstheverticalwalls.

2.3.3 Ceiling Notes

• Locate electrical devices, life safety devices and

thesprinklerheadsatthecenteroftheacoustical
ceilingtiles,unlessotherwisenoted.
• Forexistingspaces,providemin.6”fiberglass
soundrollorbattinsulationaboveceilingup
to2’oneithersideofexistingpartition,where

applicable.

Ceiling Types Type Description CL-1 ACT - Acoustical ceiling tile with suspension grid

CL-2 GBC - Gypsum board ceiling

CL-3 Open - Open to structure above

7TSA Program of Requirements1.03

2.4 Flooring

2.4.1 Flooring Types

See Flooring Types Table below

2.4.2 Flooring Criteria

• Carpet:Commercialgradecarpettile.Color
tobeselectedfrommanufacturer’sstandards.
Selectcarpetingtohavelimitedoff-gassingfrom
thecarpetfibersandcarpetbacking.Directglue-
downinstallationperguidelinesofCarpetandRug
Institute(CRI).
• Extendcarpetintotoespaces,doorreveals,
closets,alcoves,removableflanges,etc.
• VCT:Vinylcompositiontilecomplyingwith
ASTMF1066,Composition1,colorsasselectedby
TSA.Alltilesshallbearaminimumstaticcoefficient
offrictionof0.6foraccessibleroutesand0.8for
rampswhentestedunderadrycondition.All
tileswillbeselectedtohaveafireperformance

complying with the requirements of building code and local authorities.

• At expansion joints, locate joints in tile surfaces directly above the joints in concrete substrate.

Flooring Types Type Description CPT Carpet - per SFO Standard (TSA minimum requirement is 26 oz. multicolor level loop.)

VCT VCT - 12” x 12” x 1/8” vinyl composition tile per SFO standard

VCT2 VCTAS-12”x12”x1/8”anti-staticvinyl
compositiontile
VCT3 VCTHD-12”x12”x1/8”heavydutyvinyl
compositiontile

CNC Concrete - sealed concrete

• Extend tile work into toe spaces, recesses, door reveals, closets and under or behind equipment

andfixturestoformcompletecoveringwithout
interruption,unlessotherwisenoted.

• Do not saw-cut joints after installing tiles.

• Colors may be selected by local REMD approval.

• Contractor shall be responsible for leveling of floor slabs to receive specified finishes.

• Allfloorfinishchangestooccurundercenterline
ofdoorinclosedposition.
• Allpatternedflooringistobecenteredinboth
directionsandgeneratedfromcenterofroom
outwardtowardpartitions,unlessnotedotherwise.
• Carpetseamsshalloccuratjunctionof
partitions,thresholdsorchangeofdirectionin

corridor. Strip patching is not acceptable.

2.4.3 Flooring Notes

• FloorloadinginCommunicationsClosetshould
accommodate150lbs/sffortelecommunication

equipment.

• Refer to “7.6.3.2 Floor Loading” on page 63

8TSA Program of Requirements1.03

2.5 Finishes

2.5.1 Wall Finish Types

See Wall Finish Types Table below

2.5.2 Wall Finish Criteria

• Paint: Painting systems selected shall be manufactured from materials bearing low levels of volatile compounds without affecting in-service performance.

• Paint surfaces behind movable equipment and furniture the same as similar exposed surfaces.

• Paint all un-insulated metal and plastic pipes, pipe hangers and supports, panel boards and all mechanical and electrical equipment which is factory primed.

• Metals:Provideprimerandtwofinishcoats
acryliclatexsemi-gloss.
• Masonry:Providefillerandtwocoatsacrylic
latexsemi-gloss.
• Wallboard:Provideprimerandprovidetwo
coatsacryliclatex.

• Concrete: Provide primer and two coats acrylic latex semi-gloss.

• FabricWallcovering:Contenttobepolyesteror
polypropylene.Flameretardant.(asexceptiononly)
• VinylWallcovering:Allwallcoveringsshouldbe
fire-performancetestedtomeetrequirementsof
buildingcodeandlocalauthorities.(asexception

only)

• VinylBase:Colortobeselectedfrom
manufacturer’sstandards.Providevinyledgestrips
andterminationsasrequired.

• Colors may be selected by local REMD approval.

2.5.3 Wall Base Criteria

• Apply wall base to walls, columns, pilasters and cabinets in toe spaces and other permanent fixtures in rooms and areas where base is required.

• Attachorgluewallbasetightlytothewalland
floorsubstratecontinuouslythroughoutitslength

without gap at seams.

• Wall base shall not be stretched.

Wall Finish Types Type Description WF-1 Paint - per SFO standards (Eggshell finish or finish to match existing)

WF-2 Paint-perSFOstandards(Semiglossfinishat
doorframesandatBreakRoomwalls)

WF-3 VB 4” - vinyl cove base

WF-4 VW - commercial grade medium grade vinyl wall covering, mar and stain resistant; colors

tobeselectedfrommanufacturer’sstandards
(Asexceptiononly-needsREMDapproval).

WF-5 FP - Floor to ceiling fabric-wrapped 1” thick

soundabsorptionpanels(Asexceptiononly-
needsREMDapproval).

9TSA Program of Requirements1.03

2.6 Millwork

2.6.1 Millwork Types

See Millwork Types Table below

2.6.2 Millwork Criteria

• All architectural woodwork is to comply with AWI “Premium Grade Quality Standards”, 5th Edition.

• Allproductsaretobeselectedandspecified
toavoidhighoff-gassingforureaformaldehyde,
polyvinylacetate(PVA)andasphalticresinglues.
Theuseofplywoodproductsincorporatingphenol
formaldehydeorresorcinolglueswillbespecified
subjecttoBuildingCode-mandatedfire-resistance

requirements.

• Plasticlaminatefacesheetsaretocomplywith
NEMALD3,GP50;satinfinishtexture.

• Plastic laminate edges are to match face sheets and to be applied before the face sheets are applied.

• All edges should be rounded smooth.

• All hardware pulls to conform with to ABAAS Guidelines.

Millwork Types Type Description MW-1 WC - wall cabinets with adjustable shelves, 12” deep. All exposed surfaces are to have plastic laminate finish (including shelving).

MW-2 BC-basecabinets24”deepwith4”backsplashandsidesplash.Allexposedsurfacesaretohaveplastic
laminatefinishincludingcounter-tops,wallpanels,cladshelving,etc.Basecabinetryshallbedesigned
andinstalledtocomplywithArchitecturalBarriersActAccessibilityStandards(ABAAS),pertheSFO.
MW-3 CC-computercounter(optional):30”deep,1½”thicklaminatedwork-surfacewithverticalsupport
every4feet.Installgrommetsinthesurfacetoallowwiringaccess.Locationstobecoordinatedduring
drawingreview.Installaplasticbushingtoprotectwires.

MW-4 OS - open shelving. All exposed surfaces to be plastic laminate on 3/4” plywood to match base and wall cabinetry..

10TSA Program of Requirements1.03

2.7 HVAC

• Coordinatethermostatlocationswith
architecturalfloorplanforeffectivenessandto

eliminate interference with furniture.

• Temperature and humidity control should

beadjustedtothesettingsrequiredforthe
performancespecified.(RefertoHVACnotesbelow.)

2.7.3 HVAC Notes

• EF-1 Provide ceiling-mounted exhaust fan with wall-mounted switch. The fan is to be capable of providing 200 CFM and ducted to the building exhaust system. (TSO Break Room)

• SAS Provide concealed separate 24-hr operation, dedicated HVAC system, which must provide

cooling,humidityandventilationrequirementsas
describedinAppendix:StructuredCablingSystems

Guidelines, Sub-Part 6.3.4, and be controlled by a

thermostat.Heatgainperrackisestimatedat3000
BTUH.(CommunicationsCloset)

2.7.1 HVAC Types

See HVAC Types Table below

2.7.2 HVAC Criteria

• All existing ducts, plenums and air unit casings should be cleaned of all debris, dirt and dust before installing grills, registers or diffusers.

• Where ductwork, piping or conduits pass

throughfire-ratedpartition,fire-wallsorfloors,
fire-stopshouldbeprovidedtoensureaneffective
barrierforthespreadoffire,gasesorsmoke.
• Whereductworkpassesthroughfire-ratedwalls
andfloors,providefiredamperandaccesspanel.

• All annular spaces between piping, ductwork or sleeves which do not require fire-stops should be packed with mineral wool and caulked.

• HVAC system should be tested and balanced according to the design specifications.

• Supplemental HVAC unit is required at

CommunicationsRoom.Referto“7.6.3.4Heating,
VentingandAirConditioning(HVAC)”onpage63

HVAC Types Type Description HV-1 AS - Air Supply - Size: 2’ x 2’, unless otherwise noted (UON)

HV-2 AR - Air Return

HV-3 EF-1-ExhaustFancapableofproviding200
CFM(TSOBreakRoom)

HV-4 SAS - Supplemental HVAC Unit

11TSA Program of Requirements1.03

2.8 Plumbing

2.8 Plumbing

2.8.1 Plumbing Types

See Plumbing Types Table below

2.8.2 Plumbing Criteria

• Fixture rough-ins shall be compliant with ABAAS guidelines

2.8.3 Plumbing Notes

• Provide hot and cold running water to TSO break rooms and pantry areas, where applicable.

• Connect refrigerator ice maker (if applicable) to cold water supply.

• Instant hot to be installed in TSO Break Room only.

• Provide garbage disposal (GD-1)

Plumbing Types Type Description PL-1 Sink - 21” x 24” stainless steel single sink with chrome-plated brass single lever faucet.

PL-2 GD-1 - Garbage Disposal shall be one 3/4 hp, GE or equivalent with wall mounted switch.

PL-3 InstantHot–todispenseaminimumof30
cupsof190-degreeF.(approx.)waterper

hour. Provide disconnect switch under the sink.

12TSA Program of Requirements1.03

2.9 Lighting

2.9 Lighting

2.9.1 Lighting Types

See Lighting Types Table below

2.9.2 Lighting Criteria

• All luminaires in one room should be the

sametypeunlessotherwisenotedandidentical
luminairesshouldbefurnishedwithidentical

electronic ballasts.

• Anoveralllightinglevelof50foot-candlesis
requiredattasklevel.(30”AFF)

• Mount light switches on walls inside of room no higher than 48” AFF UON.

• Align edges of luminaires with walls or other building elements as indicated in the drawing.

2.9.3 Lighting Notes

• Thelightingshallutilizemultipleswitching
sothatthecenterlampofeach3-lampfixtureis

connected to one switch and the outside lamps are connected to a second switch. This allows various lighting levels using 2 switches by switching either 1 lamp on, 2 lamps on, or all 3 lamps on in each fixture.

Lighting Types Type Description LT-1 FP: Fluorescent fixture with parabolic louvers or matched to building standard

LT-2 EF:EmergencyFluorescentfixture(connected
toback-upgenerator,ifavailable)

LT-3 NL: Night Light (always on)

LT-4 THBL:TwinHeadBatteryPackLight(emer-
gencylight)

13TSA Program of Requirements1.03 *For reference only, actual configuration may vary *Not to scale

2.10 Electrical and Telecommunications

2.10 Electrical and Telecommunications

2.10.1 Electrical and Telecom Types

See Electrical & Telecommunications Table below

2.10.2 Electrical and Telecom Criteria

• Locate power for shared equipment in shared common wall or a systems furniture panel. Use of power poles is discouraged.

• All telecommunications data cables to be CAT 5E or a higher standard.

• Contractorisrequiredtoverifycalculationand
implementationofallelectricalcircuitryloadsas

required to comply with all applicable codes.

2.10.3 Electrical and Telecom Notes

• Outlet plates shall be installed flush with the finished surface.

• Provideonegroundconnectiontoeachrackin
CommunicationsCloset.

• Provide j-hook cable management above ceiling for CAT 5E cabling.

• CableTVterminationandelectricaloutletto
beinstalledinFSDOffice,FSDConferenceRoom,
TSOBreakRoomand/orCoordinationCenteronly.
LocationsshouldbecoordinatedwithFurniture

Plan.

• AllpowerinCoordinationCenterand
CommunicationsRoomshallbeconnectedto
back-uppower,and/orthebuilding’semergency

generator, if available.

• At a computer counter, mount data and

Electrical & Telecommunications Types Type Description ET-1 BF: Wall-mounted systems furniture base-feed for connection of systems power whip connection

ET-2 CB: Cable outlet for TV connection

ET-3 DPW: Wall-mounted duplex outlet

ET-4 QPW: Wall-mounted quadruplex outlet

ET-5 DPWD: Wall-mounted, dedicated 20-amp duplex outlet

ET-6 DPWG: Wall-mounted GFI duplex outlet

ET-7 VDW: Wall-mounted voice/data outlet

ET-8 DPF: Floor-mounted duplex outlet

ET-9 QPF: Floor-mounted quadruplex outlet

ET-10 VDF2: Floor-mounted voice/data outlet

ET-11 VDF4: Floor-mounted quadruplex voice/data outlet

ET-12 BVDW: Wall-mounted communication distribution box for connection to multiple workstations via system furniture panels

ET-13 BVDC: Ceiling-mounted communication distribution box for connection to multiple workstations through power poles

ET-14 JBU: Under-counter junction box (Break Room – Disposal and/or Instant hot)

ET-15 JBW: Wall-mounted junction box

ET-16 JBC: Ceiling-mounted junction box

ET-17 TOW: Wall-mounted telephone outlet

ET-18 MSW: Motion Sensor Switch (Wall)

ET-19 MSC: Motion Sensor Switch (Ceiling)

14TSA Program of Requirements1.03

*Not to scale electrical outlets 6” above counter surface.

• Eachworkstationrequirestwo(2)20Amp
circuits;oneforcomputeruseandoneforutility
use.Eachcomputercircuitshallnotexceed4
duplexoutlets(4workstations).Eachutilitycircuit
shallnotexceedeight(8)duplexoutlets.
• Eachworkstationshouldbeconnecteddirectly
tothepatchpanelintheCommunicationsRoomvia

a home-run.

• Provide one dedicated analog line in

CommunicationsRoomforeachSecurityPanel,if
applicable.(RefertoPhysicalSecurityProgramof

Requirements)

• Referto“7.0 Guidelines for Structured Cabling
Systems(Voice/Data)”onpage58 for detailed

guidelines.

15TSA Program of Requirements1.03

*Not to scale

2.11 IT Security

2.11 IT Security

ITSecurityconsiderationsforselectionofaTSA
OfficeincludingTelecommunicationsRoom(TR)
oraTelecommunicationsCabinet(TC)forhousing
ITequipmentareanintegralpartoftheinitial
evaluationprocessofamarketsurvey.ITSecurity
requirementsmustbemetforC&Aprocessesand

FISMA compliance.

2.11.1 TelecommunicationsRoom
TheTSATelecommunicationsRoom(TR)is
thedesignatedlocationforcoreinfrastructure
equipmentincludingtelecommunications,network,
andotherinformationsystemsthatsupportTSA
operationsatlocalairportsorotherTSAoffices.
ThefollowingitemsmustbeevaluatedforTR
forplacementofinformationsystems,network
communicationdevices,orotherITcomponentsthat
directlysupporttheTSAfacilityoroperations.
• TSATelecommunicationsRooms(TR)shallbe
dedicatedtotelecommunications,networkingor
supportinginformationtechnologysystemsorend
userconnectivityonly.TheTRshallnotbeusedfor

non-IT purposes such as storage or a break room.

• Equipment not related to telecommunications shall not be installed, pass through or enter the telecommunications room. Examples include:

baggage handling equipment, cooking equipment,

waterpipes,firesuppressionsystemsnot
supportingtheTR,etc.
• Minimumoneclosetperfloortohouse
telecommunicationsequipment/cableterminations

and associated cross-connect cable and wire.

• TheTRmustbelocatednearthecenterofthe
areabeingserved.Extendedcablerunsandthe
useofrepeatingequipmentisdiscourageddueto
theadditionalsecurityrisksofcablebreachesand
additionalequipmentthatmaynotbeadequately

monitored.

• Horizontal pathways shall terminate in the

telecommunicationsroomonthesamefloorasthe
areaserved.Cablerunsbetweenmultiplefloors
mustonlyoccurto/fromeachTR.Ad-hoccableruns
betweenfloorsmustbeavoidedtopreventcable

compromise.

• FalseceilingsmustnotbeusedinTRlocations.
TheabilitytoclimboverawallintoaTRbypassing

other physical security controls shall be prevented.

• PhysicalaccesstotheTRiscontrolled;Solidcore
doorswithnogratesshallbeusedforTRdoors,
andaccessshallbecontrolledwithmulti-factor
authenticationdoorlocks.Windowsandother

mechanisms that could be used to circumnavigate

physicalsecuritycontrolsshallnotbeallowedinTR
locations.TRlocationsshallneverbeeasilypublicly

accessible.

• HVAC requirements shall be appropriate to maintain the TR. High temperatures can cause equipment failures and shorten the lifespan of information Technology Systems. Environmental temperature and humidity controls shall be available to maintain equipment to adequate operational capabilities in accordance with TSA IT Security Policy. HVAC systems shall maintain a separate adjustable thermostat located in the

TR,andmustbeavailable24/7/365withfull
operationalcapabilities.

• Emergency Room Power Shutoff switches may or may not be available; however, if unavailable, TSA shall install a secondary switch to allow

powershutdownofUninterruptiblePowerSupply
(UPS)whilepersonnelareinsidetheTRincaseof

emergency.

• TRshallhavefiresuppressionequipment
thatcanbeactivatedincaseofafire.Inthecase
thatnofiresuppressionequipmentisavailable,
compensatingcontrolssuchasfireextinguishers
mustbeprovidedfortheTRinaccordancewith
localbuildingcodesforTRorcomputerrooms.
• TRshallnotbelocatedwherefloodinghas
occurredorisexpectedtooccurduetothehazard
posedbywatertoinformationsystems.

16TSA Program of Requirements1.03

*Not to scale

2.11.2 TelecommunicationsCabinet
Occasionally,whenthereisoftennootherlocation

to place IT systems and equipment, a cabinet is wall mounted with IT systems housed in the storage areas

ofthecabinet,referredtoasTelecommunications
Cabinets(TC).TelecommunicationsCabinetsshall

not be used to house core infrastructure equipment.

The following items must be evaluated for TC usage with information systems, network communication devices, or other IT components that directly support the TSA facility or operations.

• The TC must be dedicated to

telecommunications,networkingorsupporting
informationtechnologysystemsorenduser
connectivityonly.TheTCshallnotbeusedfornon-
ITpurposessuchasstorageofsensitiveinformation,
orasalocationfor‘safekeeping’ofnon-ITitems.

Paper and printer supplies shall not be stored in the

TC.

• All equipment must be able to be wholly contained in the TC. Electrical outlets shall be installed so that they are located inside the cabinet and protected by the cabinet instead of being installed outside of the cabinet and the equipment being vulnerable to the cable being removed from the cabinet.

• All network cabling must be wholly contained in the TC; Network cabling that is not contained in the TC must have a separate cabinet or use conduit to prevent unauthorized access to any network cabling. Cable runs that allow public access to the physical medium is prohibited.

• WideAreaNetworkconnectivitymustbe
containedintheTCincludingtelecommunications
ports,telecommunicationssupportingequipment,
andanyfirewall/switching/routingequipmentin

use.

• Physical access to the TC is controlled; The TC shall be physically installed as far as possible from non-TSA personnel access to prevent unauthorized access. Placing TC in publicly accessible areas shall be avoided.

• Environmental controls must be evaluated for the TC. The TC shall be installed away from

potentialenvironmentalhazardssuchaswater
pipes,excessiveheatproducingequipment,orother
potentialenvironmentalhazardstotheinformation

technology equipment. Placing computer equipment in high temperature, high humidity, and

orinlocationswhereexcessivedirt,dust,oil,grease
orotherdebriscanrenderinformationsystems

inoperable.

• Monitors and other IT display equipment shall be controlled to authorized viewing for users working on systems in the TC.

• The ability to quickly disable power to the TC shall be evaluated. An electrical breaker shall be available and or another mechanism to stop power to the TC in the case of an emergency.

• Fireextinguishersmustbeinstalledwithin6
feetoftheTCtoaddressanydangerposedbyfire
orfireextinguishersmustbeinstalledtomeetfire

suppression equipment requirements in accordance with local building codes.

17TSA Program of Requirements1.03

2.12 Equipment

2.12 Equipment

2.12.1 Equipment Types

See Equipment Types Table below

2.12.2 Equipment Notes

• Providewall/ceilingmountedTVrack,if
applicable,forTV.Rackistobesuppliedand

installed by GC and coordinated with TSA point of contact. Television is to be supplied by the TSA Program Office.

• Microwaves are to be supplied by the local TSA Office and may be existing. The new location may either be above counter or below counter;

dimensions and power requirements should be coordinated.

Equipment Types

Type Description

EQ-1 MW - medium to heavy-duty commercial microwave oven, with a capacity of approx.

1.2 CF.

EQ-2 REF–refrigeratorwithicemaker,GEorequiva-
lent.Typicalcapacityshouldbeapprox.21

cubic feet.

EQ-3 CM:Coffeemaker(single-cupormulti-cup
unit)basedonnumberofstaff

18TSA Program of Requirements1.03

3.0 Deliverables

3.1 Dissemination of Sensitive

Documents

GSA and the Federal Government are concerned with the safety and security of persons and property under their control. The contractor should ensure

thatreasonablecareisprovidedtoprotectsensitive
information,bothinpaperandelectronicformat,
regardingbuildingdrawingsandspecificationsfor
design,constructionand/orrenovation,security
equipmentandinstallation,andcontractguard
informationrelatedtoGSA-controlledfacilitiesfrom

being used for illegal purposes. All documents and drawings shall be password protected.

3.1.1 Sheet File Security Imprint

Imprint for all building plans, drawings, and

specificationspreparedforconstructionor
renovation,and/orsecurityservices,eitherin

electronic or paper formats, shall have included on

eachsheetfileoftheconstructiondrawingsorplans
inaminimumof14pointboldfacetype(3mmor
about1/8”)andshallbevisibleinbothpaperspace
andmodelspace:

PROPERTY OF UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice. Properly destroy docu-ments when no longer needed.

3.1.2 Cover Sheet Security Imprint

The following paragraph will be noted on the cover page of all drawing sets and on the cover page of the

specificationsinaminimumof14pointboldface
type(3mmorabout1/8”):

PROPERTY OF THE UNITED STATES GOVERN-

MENT COPYING, DISSEMINATION, OR DISTRI-

BUTION OF THESE DRAWINGS, PLANS, OR SPEC-

IFICATIONS TO UNAUTHORIZED PERSONS IS

PROHIBITED

Do not remove this notice. Properly destroy docu-ments when no longer needed.

3.1.3 Deliverable File Formats

• Drawings - shall be readable by AutoCAD Version

2011.Being“readable”isconstitutedbytheability
toopenafilewithoutanyerrors,suchasproxy,font
substitution,XREFresolution,etc.,andtheobjects,
layers,etc.inthefileremainingintact.Whena

hard copy drawing in the drawing set includes photographs or other images the electronic file submission shall include a corresponding AutoCAD

*.DWGsheetfilecontainingtheserasterimagesas
XREFsorembeddedfiles.

• Documents - shall be Microsoft Word files.

Macros may be included with these documents

providedtheyarevirusfree,theirfunctionis
explainednexttothecode,andarenotwrite-

protected.

19TSA Program of Requirements1.03

• Spreadsheets-shallbeMicrosoftExcelfiles.
Graphicsmaybesubmittedin*.TIF,*.GIF,*.JPG,
*.CALS,*.PDFor*.BMPfileformatonly.Thisoption

is intended for photos, conceptual sketches, etc.,

andnotasanindicationthatrasterfiledrawingswill
beacceptedinlieuofAutoCADfiles.

• Schedules - shall be Microsoft Project files saved with a baseline.

• Deliverablesintegratingmultiplefileformats
maybesubmittedin*.PDFfileformat(tomaintain
formatting)inadditiontothebasefilestructure.
Examplesincludereports,photographs,and
manualscreatedbyusingavarietyofsoftware
packagesandfileformats.

The contractor shall be responsible for software and data upgrades throughout the contract lifecycle.

3.1.4 ThirdPartySoftwareCriteria
AwrittenrequestmustbesubmittedtoREMDand

permission granted in order to submit electronic data in a format other than those specifically named above. This includes AutoCAD add-on

applicationsthatleavenon-nativeobjectsin
drawingsandAutoCAD-integratedapplications,such

as Architectural Desktop. When it is considered in the best interest of the Government, the TSA Project

Managermaypermitthirdpartysoftware.Anythird
partysoftwareusedthatmodifiesorcreateslayers

in AutoCAD shall adhere to the AIA CAD Layering Guidelines.

3.1.5 Design Intent Drawing

CONTENTS Standards

I. Cover Sheet

a. Project name and address

b. Contract number

c. Submission date

d. Architectural/Designfirm(includingaddress
andphonenumber)

II. Legends Sheet

a. Materials and symbols legends

b. Index (contents description)

c. Abbreviations

d. Partition types

e. General notes and requirements

III. DemolitionPlan
a. Constructiontelephone,dataandelectricto

be removed

b. Partitions and/or doors to be removed

c. General notes and symbol legend

d. Graphic scale

IV. Partition Plan

a. Walls and doors

b. Partition type symbols

c. Door numbers

d. General and key notes

e. Elevation references

f. Symbols legend

g. Graphic scale

h. Electrical and Security Plans

i. Electric symbols

j. Symbols dimensioned both horizontal and vertical

k. Datasymbols(wallmounted,floormounted,
forequipment)

l. Security equipment symbols and specifications

m. General and key notes

n. Graphic scale

V. ReflectedCeilingPlan
a. LightFixtures
b. Fixturelegend

c. General and key notes

d. Graphic scale

VI. Finish Plan and Schedule

a. Finish legend and schedule

b. General and key notes

c. Graphic scale

VII. Door and Hardware Schedule

a. Door and frame specifications

b. Door frame types

c. Hardware schedule

d. General and key notes

VIII. Generic Furniture and Equipment Plan

a. Private office furniture and workstations

b. Electrical and Data symbols

c. Equipment (printers, fax machines, copiers)

d. Furniture legend

e. General and key notes

f. Graphic scale

g. SectionDetails
h. Breakroommillwork(dimensionedand

annotated)

i. Graphic scale

IX. Interior Elevations

20TSA Program of Requirements1.03

3.1.6 ElectronicSubmittals
Inadditiontofullsizehardcopydrawingsets,

the contractor shall submit each drawing sheet electronically in .PDF or .DWF format for review

submittals.Thecontractorshallincludethemost
currentviewingsoftwarewitheachsubmittal.Adobe
Readerviewerfor.PDFfilesisavailablefordownload
atwww.adobe.com.AutodeskExpressViewerfor
.DWFfilesisavailablefordownloadatusa.autodesk.
com.Finalsubmittalsshallbein.DWGformatusing

AutoCAD version 11 or newer.

All drawings submitted to REMD for review and approval shall be in .DWG format. The TSA POC shall

receiveeitherahardcopy.PDFor.DWF(alongwith
AutoDeskExpressViewer)formatforreviewand

approval.

3.1.7 Quantities

Contractorshall,attheminimum,provideone(1)set
ofelectronicfilesonCD-ROMandtwo(2)hardcopy
setofdrawingstoTSApersubmittal.
3.1.8 EmailTransmittals
AllAutoCADfilestransmittedviae-mailshallbe
passwordprotectedusingthe‘e-transmit’command.

All Other Deliverables

3.1.9 Space Plans

GenericfloorplanshowingTSAleasedarea.The
planshouldshowpartitionswithroomnames
(correspondingtothespacesinthePOR)andsquare
footages,andabasicfurniturelayout.Critical

dimensions should be used where necessary.

3.1.10 ConstructionDocuments
AtthediscretionofTSA,ConstructionDocuments

which include complete details of the following may be required:

a. Mechanical

b. Electrical

c. Plumbing

d. Fire Safety

e. Lighting

f. Power Plan

g. Structural

h. Architectural Improvements

3.1.11 As-Built Drawings

If available, As-Built drawings should be provided

priortosigningalease.Thiswillallowanyexisting
conditionstobeidentifiedthatmayadverselyimpact

the new project.

Ataminimum,As-Builtdrawingsshallbesubmitted
toREMDwithin30daysofprojectcompletion.
3.1.12 CostEstimates
CostEstimatesshouldbeformattedaccordingtothe
ConstructionSpecificationsInstitute(CSI)format.