Exhibit B ASR SIB.pdf
PDF 443 KB Posted
- Solicitation number
- 0CA3024
About this file
This document is a set of architectural drawings and diagrams for a federal contract opportunity related to a public interview bay (SIB) workspace. The drawings provide detailed design specifications for the layout, dimensions, and components of the SIB workspace, including a public-side fixed-height work surface, employee workstation furniture, electrical and data connectivity, and acoustic wall panels.
The related federal contract opportunity is a solicitation from the General Services Administration (GSA) to lease office or retail space in Los Angeles, CA. The required space is between 10,175 and 11,701 ABOA square feet, with 2 parking spaces, for a 15-year lease term with a 10-year firm term. The space must meet various requirements for column spacing, dimensions, public transportation access, fire safety, accessibility, seismic, and sustainability standards. Offers are due by May 22, 2024, with an estimated occupancy date of January 11, 2027. The solicitation number is 0CA3024.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 0CA3024 RLP Amendment 1.pdf | ||
| Exhibit B ASR FOTDG.pdf | ||
| Exhibit D 3516.pdf | ||
| Exhibit B ASR Security SOW.pdf | ||
| Exhibit B Space.pdf | ||
| Exhibit G 1217.pdf | ||
| Exhibit B ASR Roll-A-Shade.pdf | ||
| Exhibit J FAR 52.204.pdf | ||
| Exhibit I Seismic Forms.pdf | ||
| Exhibit H Form12000.pdf | ||
| Exhibit E 3517B.pdf | ||
| Sensitive Information.pdf | ||
| Exhibit B ASR.pdf | ||
| Exhibit A Lease.pdf | ||
| Exhibit C FSL II.pdf | ||
| Delineated Area Map.pdf | ||
| Exhibit F 1364.pdf | ||
| Request for Lease Proposal .pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A2.01
A2.01
CL
R
6'
- 0
CL
R 6'
- 0
4' - 0" 2' - 5"
PUBLIC
INTERVIEW
BAY
SIB
WORKSTATION
*5'-0" WHERE SCHEDULED
MIN CLR
3' - 0" EQ EQ
A2.01
A2.014
2" MIN
CLR
6' - 0"
1/ 2"
3'
- 0
(± 4") 2' - 0"
(± 4") 2' - 0"
PUBLIC SIDE
EMPLOYEE SIDE
POWER AND
DATA
RECEPTACLE
DATA PORT
GRAY RECEPT -
COMPUTER
ASSIGNED
WATTAGE -
300VA
CONVENIENCE
RECEPT -
180VA EA
NOTES:
1. COORDINATE LOCATION OF
OUTLETS/DATAPORTS WITH C70 TABLE MODESTY
PANEL TO INSURE ACCESS TO OUTLET AFTER
INSTALL
EQ
OPENING
MATCH WINDOW
EQ BEYOND FACE OF WALL
EXTEND
WORKSURFACE 1/2"
PUBLIC WORK
SURFACE EXTENDS
THROUGH BARRIER
WALL AT ROXBURY
WINDOW-WINDOW
RESTS ON TOP
DATE
"P R
O
PE
R
TY
O F
TH
E
U N
IT
ED
S
TA
TE
S
G O
VE
R
N M
EN
T
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
"DIAGRAMMATIC DESIGN INTENT - NOT FOR CONSTRUCTION"
SCALEFLOOR PLAN
A1.01 06/21/2023
1/2" = 1'-0"
1 BARRIER WALL FLOOR PLAN
PLAN NOTES
1 GC TO PROVIDE A PUBLIC-SIDE FIXED-HEIGHT
WORKSURFACE FOLLOWING NATIONAL FURNITURE
STANDARDS OF 30” HEIGHT (±, ABA REQUIRES 28"MIN -
34"MAX), 24" DEPTH. INCLUDE A 3" DIAMETER GROMMET
FOR SHPC WORKSTATION USE. PROVIDE BLOCKING FOR
WORKSURFACE AND BRACKET SUPPORTS AS REQUIRED.
WORKSURFACE FINISH COLOR “WILSONART, AMBER
CHERRY". WORKSURFACE AND BRACKETS TO COMPLY
WITH ALL ABA REQUIREMENTS.
2 EMPLOYEE WORKSTATION COMPONENTS PROVIDED BY
DFS INCLUDES: C70 ADJUSTABLE TABLE, WALL HUNG
SHELF, TACK BOARD, WORKSURFACE WITH MOUNTING
BRACKETS (WALL TRACK INCLUDED), DUAL CLAMP
MONITOR ARM BOX/BOX/FILE PEDESTAL, TASK LIGHT,
EMPLOYEE ERGO CHAIR, PUBLIC GUEST CHAIRS.
3 SHPC IN-WALL ELECTRICAL RECEPTACLE/DATA
CONNECTIVITY FOR BOTH PUBLIC AND STAFF MONITORS.
PROVIDE (1) CONVENIENCE RECEPTACLE (1)
UNSWITCHED RECEPTACLE FOR COMPUTER POWER
LOCATED CENTER OF WINDOW (1) RECEPTACLE FOR C70
ADJUSTABLE TABLE. COORDINATE LOCATION OF C70
RECPTACLE WITH CLEARANCES OF C70 TABLE. SHPC
RECIPIENT BAYS TO BE IDENTIFIED BY SSA. PROVIDE
TAMPER PROOF COVER AT PUBLIC SIDE. SEE FOTDG FOR
FURTHER INFORMATION.
4 PUBLIC ENTRY: HOLLOW-METAL CASED OPENING-MIN 3'-0"
CLR DIM.
5 GC TO PROVIDE BLOCKING FOR FIXED HEIGHT
WORKSURFACE AND WALL HUNG SHELF MOUNTED 16"
ABOVE THE WORKSURFACE. ALLOW 1" GAP-DISTANCE
TOLERANCE BETWEEN FIXED WORKSURFACE AND C70.
WORKSURFACE AND SHELF TO COMPLY WITH ALL ABA
REQUIREMENTS.
6 PROPOSED DURESS BUTTON LOCATION. FINAL LOCATION
TO BE COORDINATED WITH OSEP. COORDINATE BUTTON
WIRING LENGTH WITH C70 TABLE MOVEMENT RANGE. SEE
FOTDG FOR FURTHER INFORMATION.
1/4" = 1'-0"
RECEPTACLE DIAGRAM
GENERAL NOTES
1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS SPAN
FROM FINISH FACE TO FINISH FACE.
2. ALL CONSTRUCTION SHOULD BE COORDINATED WITH
REQUIREMENTS OF FURNITURE SYSTEMS.
3. COORDINATE DRAWING REQUIREMENTS WITH
REQUIREMENTS LISTED IN FOTDG.
3 PUBLIC WORKSURFACE DIAGRAM
INTERVIEW CORRIDOR PUBLIC EMPLOYEE
WALL ASSEMBLY:
3-5/8" METAL STUD,
5/8" GYPSUM
BOARD, R13 ROCK
WOOL INSULATION
4'-6" X 3'-0" RECESSED
TRANSACTION
WINDOW
EXTEND WALLS 6"
ABOVE FINISH CEILING-
TYP. REFER TO FOTDG
FOR INTERVIEW BAY
ACOUSTIC
PERFORMANCE
REQUIREMENTS TO
MEET OR EXCEED
INTERVIEW CORRIDOR
SCREEN WALL WITH
FIXED 36"X53" DUAL-
PANE WINDOWS - SILL
HEIGHT 2'-8" - TYP
ROLL DOWN
TRANSACTION WINDOW
SHADE WITH WALL
BLOCKING
COORDINATE LOCATION
OF OUTLETS/DATAPORTS
WITH C70 TABLE
MODESTY PANEL TO
INSURE ACCESS TO
OUTLET AFTER INSTALL
ACOUSTIC WALL PANELS
TO
C
LG
PA
NE
L
EX
TE
ND
S
W
DW
T
RI
M
P
AN
EL
1/
2" M
IN
G
AP
B
TW
N
WHERE ACOUSTIC PANELS ARE
ADJACENT TO WINDOW TRIM OR
DOOR JAMBS - PROVIDE 1/2" MIN CLR
GAP BETWEEN TRIM/JAMBS AND
ACOUSTIC PANEL - TYP AT ALL
PANEL LOCATIONS
PLAM WALL BOARD PROTECTION -
MATCH WALL COLOR, AND
PROVIDE VINYL COVE BASE - TYP
ALL BAY WALLS
RE
CO
M M
EN
DE
D
0"
4' - 6"
3'
- 0
PLAN NOTE 3 ON /1 A1.01
ACOUSTIC WALL PANELS - 1" MIN /
NRC 0.90 / D MOUNTING TYPE -
VERTICAL DIMENSIONS BEGIN AT TOP
OF WORKSURFACE - TYP FOR ALL
ACOUSTIC PANELS
ACOUSTIC WALL
PANELS
FIXED 36" X 53" DUAL
PANE WINDOW -
SILL HEIGHT 2'-8" -
TYP
EMPLOYEE PUBLIC
3' - 3" 2' - 6"
4'
- 6
W
DW
T
RI
M
P
AN
EL
1/
2" M
IN
G
AP
B
TW
N
TO
C
LG
PA
NE
L
EX
TE
ND
S
FIXED 24" X 53" DUAL
PANE WINDOW - SILL
HEIGHT 2'-8" - TYP
OPEN TO
BEYOND
DATE
"P R
O
PE
R
TY
O F
TH
E
U N
IT
ED
S
TA
TE
S
G O
VE
R
N M
EN
T
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
"DIAGRAMMATIC DESIGN INTENT - NOT FOR CONSTRUCTION"
SCALESECTIONS, ELEVATIONS & DIAGRAMS
A2.01 06/21/2023
1/4" = 1'-0"
5 SECTION - EAST
1/4" = 1'-0"
3 ELEVATION - NORTH - STAFF BAY
1/4" = 1'-0"
1 ELEVATION - SOUTH - PUBLIC BAY
1/4" = 1'-0"
4 ELEVATION - WEST
1/4" = 1'-0"
2 ELEVATION - NORTH - PUBLIC BAY
ACOUSTIC WALL
PANELS - 2 WALLS
TRANSACTION
WINDOW AND
COUNTER
SOME WALLS AND FEATURES SHOWN DASHED TO
IMPROVE VISIBILITY--REFER TO A1.01 FOR FULL
BAY DESIGN INFORMATION
CEILING
WALLS EXTEND
ABOVE CLG PER
NOTES ON A1.01
ACOUSTIC WALL
PANELS - 2 WALLS
SOME WALLS AND FEATURES SHOWN DASHED TO
IMPROVE VISIBILITY--REFER TO A1.01 FOR FULL
BAY DESIGN INFORMATION
DATE
"P R
O
PE
R
TY
O F
TH
E
U N
IT
ED
S
TA
TE
S
G O
VE
R
N M
EN
T
FO
R
O
FF
IC
IA
L U
SE
O
N
LY
"DIAGRAMMATIC DESIGN INTENT - NOT FOR CONSTRUCTION"
SCALE3D ISOMETRIC DRAWINGS
A3.01 06/21/2023
2 TYPICAL SIB BAY - PUBLIC BAY1 TYPICAL SIB BAY - SSA EMPLOYEE BAY
| Sheets |
| A1.01 - FLOOR PLAN |
| A2.01 - SECTIONS, ELEVATIONS & DIAGRAMS |
| A3.01 - 3D ISOMETRIC DRAWINGS |
File details come from the government source that posted it. Updated .