EXHIBIT_A_–_Garland_roof_replacement_drawing_set.pdf

PDF 1 MB Posted

Attached to
224 W. Winton Building Roof Replacement
Solicitation number
902811
Issued by
Alameda County, Hayward City, California

About this file

This file is a comprehensive drawing set prepared by The Garland Company, Inc., for the County of Alameda's roof replacement project at 224 W. Winton Avenue, Hayward, California 94544. The document package contains ten sheets detailing the complete roof replacement scope, including a cover sheet, scope summary, general notes, and roof plan with a scale of 1/32" = 1'-0". The drawing set provides detailed specifications for the roof assembly and associated components, with the contractor bearing responsibility for field verification of all dimensions, conditions, and quantities prior to execution.

The technical details encompass 22 distinct construction details addressing the full range of roofing elements required for the project. These include specifications for the typical roof assembly, curbs, equipment supports, exhaust fans, vent intakes, roof hatches, drains, metal edges, wall flashings at multiple locations, roof-penetrating elements (skylights, heat stacks, plumbing stacks), expanding eaves, fixed shed ridges, rakes, pipe penetrations, and pipe scrims. Various scale specifications are provided throughout the detail sheets, ranging from 3" = 1'-0" for certain details to not-to-scale (NTS) notations for others. The drawing set also indicates the presence of solar panels on the roof, denoted as "typical" elements in multiple locations on the roof plan, though these appear to remain in place during the replacement work.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHT 1 - COVER SHEET

SHT 2 - SCOPE

SHT 3 - NOTES

SHT 4 - ROOF PLAN

SHT 5 - DETAILS

SHT 6 - DETAILS

SHT 7 - DETAILS

SHT 8 - DETAILS

SHT 9 - DETAILS

SHT 10 - DETAILS

DRAWING INDEX

LOCATION MAP

KEY PLAN

ALAMEDA COUNTY OFFICES

ROOF REPLACEMENT

224 W WINTON AVE, HAYWARD, CA 94544

OF

SHEET:

RE

VI

SI

ON

DA

TE

CH

K

BY

DW

G

BY

PH

O

NE

(8

) 3

-9

/ F

AX

(2

) 6

-0

E

AS

T st S

TR

EE

T

- C

LE

VE

LA

ND

, O

HI

O

-2

T

H E

G A

R

LA

N D

C O

M P

A N

Y

IN

C

AG

EN

T:

G

AR

LA

N D si nc e

AL

AM

ED

A

CO

UN

TY

Ala me da C ou nty

O ffic es

4 W W

IN

TO

N

AV

E, H

AY

W

AR

D, C A

7-

-2

DC

GC

K

DO

UG

C

LA

RK

AREAS OF

WORK

EXIHIBT A

Garland roof replacement drawing set.

N.I.C.

N.I.C.

N.I.C.

SOLAR PANELS (TYP)

SOLAR PANELS (TYP)

SOLAR PANELS (TYP)

SCALE: 1/32" = 1'-0"

ROOF PLAN

NOTE:

CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY

ALL DIMENSIONS, CONDITIONS AND QUANTITIES.

SYMBOL LEGEND

OF

SHEET:

RE

VI

SI

ON

DA

TE

CH

K

BY

DW

G

BY

PH

O

NE

(8

) 3

-9

/ F

AX

(2

) 6

-0

E

AS

T st S

TR

EE

T

- C

LE

VE

LA

ND

, O

HI

O

-2

T

H E

G A

R

LA

N D

C O

M P

A N

Y

IN

C

AG

EN

T:

G

AR

LA

N D si nc e

AL

AM

ED

A

CO

da C ou nty

O ffic es

4 W W

IN

TO

N

AV

E, H

AY

W

AR

D, C A

7-

-2

DC

GC

K

DO

UG

C

LA

RK

1. TYPICAL ROOF ASSEMBLY, DTL A/5

2. CURB, DTL B/5

3. EQUIPMENT SUPPORT, C/5

4. EXHAUST FAN, DTL D/5

5. VENT INTAKE, DTL E/5

6. ROOF HATCH, DTL F/6

7. ROOF DRAIN, DTL G/6

8. METAL EDGE, DTL H/6

9. WALL FLASHING AT CEMENT WALL, DTL J/6

10. SURFACE MOUNTED COUNTERFLASHING,

DTL K/6

11. WINDOW SILL FLASHING, DTL L/6

12. SCUPPER THRU WALL, DTL H/6

13. COPING CAP AT WALL, DTL G/6

14. PIPE HOUSING, DTL F/5

15. SKYLIGHT, DTL Q/7

16. HEAT STACK, DTL R/8

17. PLUMBING STACK, DTL S/8

18. EXPANDING EAVE, DTL T/9

19. FIXED SHED RIDGE, DTL U/9

20. RAKE, DTL Y/9

21. PIPE PENETRATION, DTL W/10

22. PIPE SCRIM, DTL X/10

SCALE: 11

2" = 1'-0"

B

HANDLING STATION

CURB DETAIL / AIR

SCALE: 11

2" = 1'-0"

C

PREMANUFACTURED - EXISTING

EQUIPMENT SUPPORT

SCALE: 11

2" = 1'-0"

D

EXHAUST FAN

SCALE: 11

2" = 1'-0" E

PASSIVE AIR / VENT INTAKE

SCALE: 3" = 1'-0"

A

COATED SURFACE

TYPICAL ROOF SYSTEM

OF

SHEET:

RE

VI

SI

ON

DA

TE

CH

K

BY

DW

G

BY

PH

O

NE

(8

) 3

-9

/ F

AX

(2

) 6

-0

E

AS

T st S

TR

EE

T

- C

LE

VE

LA

ND

, O

HI

O

-2

T

H E

G A

R

LA

N D

C O

M P

A N

Y

IN

C

AG

EN

T:

G

AR

LA

N D si nc e

AL

AM

ED

A

CO

da C ou nty

O ffic es

4 W

W

IN

TO

N

AV

E, H

AY

W

AR

D, C

A

7-

-2

DC

GC

K

DO

UG

C

LA

RK

F

HATCH DETAIL

SCALE: 11

2" = 1'-0" H

METAL EDGE - GRAVEL STOP

SCALE: 11

2" = 1'-0" G

ROOF DRAIN RETROFIT

SCALE: 11

2" = 1'-0"

J

EXISTING CEMENT PLASTER WALL

WALL FLASHING AT

SCALE: 11

2" = 1'-0"

L

WINDOW SILL FLASHING

SCALE: 11

2" = 1'-0" K

SURFACE MOUNTED COUNTERFLASHING

WALL FLASHING -

OF

SHEET:

RE

VI

SI

ON

DA

TE

CH

K

BY

DW

G

BY

PH

O

NE

(8

) 3

-9

/ F

AX

(2

) 6

-0

E

AS

T st S

TR

EE

T

- C

LE

VE

LA

ND

, O

HI

O

-2

T

H E

G A

R

LA

N D

C O

M P

A N

Y

IN

C

AG

EN

T:

G

AR

LA

N D si nc e

AL

AM

ED

A

CO

da C ou nty

O

W

IN

TO

N

AV

E, H

AY

W

AR

D, C

A

7-

-2

DC

GC

K

DO

UG

C

LA

RK

P

PIPE HOUSING

SCALE: 11

2" = 1'-0"6

SCUPPER THROUGHWALL - OVERFLOW

SCALE: 11

2" = 1'-0" M

SCUPPER THROUGHWALL - OVERFLOW

SCALE: 11

2" = 1'-0"

Q

SKYLIGHT W/PROTECTION SCREEN

SCALE: NTS

N

COPING CAP

OF

SHEET:

RE

VI

SI

ON

DA

TE

CH

K

BY

DW

G

BY

PH

O

NE

(8

) 3

-9

/ F

AX

(2

) 6

-0

E

AS

T st S

TR

EE

T

- C

LE

VE

LA

ND

, O

HI

O

-2

T

H E

G A

R

LA

N D

C O

M P

A N

Y

IN

C

AG

EN

T:

G

AR

LA

N D si nc e

AL

AM

ED

A

CO

da C ou nty

O

W

IN

TO

N

AV

E, H

AY

W

AR

D, C

A

7-

-2

DC

GC

K

DO

UG

C

LA

RK

R

HEAT STACK

SCALE: 11

2" = 1'-0" S

PLUMBING STACK - FIELD FABRICATED

OF

SHEET:

RE

VI

SI

ON

DA

TE

CH

K

BY

DW

G

BY

PH

O

NE

(8

) 3

-9

/ F

AX

(2

) 6

-0

E

AS

T st S

TR

EE

T

- C

LE

VE

LA

ND

, O

HI

O

-2

T

H E

G A

R

LA

N D

C O

M P

A N

Y

IN

C

AG

EN

T:

G

AR

LA

N D si nc e

AL

AM

ED

A

CO

da C ou nty

O

W

IN

TO

N

AV

E, H

AY

W

AR

D, C

A

7-

-2

DC

GC

K

DO

UG

C

LA

RK

SCALE: 3" = 1'-0"

T

EXPANDING EAVE

SCALE: 3" = 1'-0"

U

FIXED SHED RIDGE

SCALE: 3" = 1'-0"

V

RAKE DETAIL

OF

SHEET:

RE

VI

SI

ON

DA

TE

CH

K

BY

DW

G

BY

PH

O

NE

(8

) 3

-9

/ F

AX

(2

) 6

-0

E

AS

T st S

TR

EE

T

- C

LE

VE

LA

ND

, O

HI

O

-2

T

H E

G A

R

LA

N D

C O

M P

A N

Y

IN

C

AG

EN

T:

G

AR

LA

N D si nc e

AL

AM

ED

A

CO

da C ou nty

O

W

IN

TO

N

AV

E, H

AY

W

AR

D, C

A

7-

-2

DC

GC

K

DO

UG

C

LA

RK

SCALE: NTS

W

PIPE PENETRATION

SCALE: NTS

X

PIPE SCRIM

OF

SHEET:

RE

VI

SI

ON

DA

TE

CH

K

BY

DW

G

BY

PH

O

NE

(8

) 3

-9

/ F

AX

(2

) 6

-0

E

AS

T st S

TR

EE

T

- C

LE

VE

LA

ND

, O

HI

O

-2

T

H E

G A

R

LA

N D

C O

M P

A N

Y

IN

C

AG

EN

T:

G

AR

LA

N D si nc e

AL

AM

ED

A

CO

da C ou nty

O

W

IN

TO

N

AV

E, H

AY

W

AR

D, C

A

7-

-2

DC

GC

K

DO

UG

C

LA

RK

File details come from the government source that posted it. Updated .