Exhibit_A-2_Plans.pdf

PDF 8 MB Posted

Attached to
C5612927-D RE-BID 1-WATER BASED DELUGE FIRE PROTECTION SYSTEM
Solicitation number
0000036375
Issued by
Trinity County, California

About this file

These are construction and engineering drawings for a Synthetic Natural Gas (SNG) Plant project for the California Department of Corrections and Rehabilitation (CDCR), with bid number C5612927-D Re-Bid 1. The plans detail a comprehensive site layout for a liquefied petroleum gas (LPG) system, including a 30,000-gallon LPG storage tank, flare stack, air blend mixer, liquid supply pump, and associated piping and safety systems. The drawings provide technical specifications for equipment installation, including seismic safety controls, emergency shut-off stations, fire protection systems, and detailed pneumatic and control system configurations.

The project drawings include extensive technical details such as material lists, valve specifications, piping diagrams, and safety signage requirements. Key safety features include emergency shut-off valves, fire extinguisher locations, alarm stations, and seismic detection systems. The design incorporates multiple redundant safety mechanisms, including pneumatic controls, bypass valves, and fail-safe systems for the LPG infrastructure. The plans are approved by both the California Department of Corrections and Rehabilitation Access Compliance Review and the California State Fire Marshal, indicating compliance with state regulatory standards for industrial gas system installations.

View the file

Other files

File Type Posted
Addendum_2.pdf PDF
Exhibit_A-1_SPECS.pdf PDF
Exhibit_B-1-Public_Works_Rate_Sheet.xlsx XLSX spreadsheet
IFB_Package_C5612927-D__Re-Bid_1_8-8-2025.pdf PDF
Addendum_1.pdf PDF
Addendum_3.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

-0

, 507 i

1. . ' t ·· • l • i j

'0'!f ' • ~"""" ' ':

~• H

) i i;

' ~ . . l ._ .

' ; \, > i; '.': .. ;

·. l '·

' i r

' '·; ... 24 ·•···• ,, \ 1·.• .·•·. '• . . · . c:~.:,,_, ;"\. : L - .

~ -w., .. -

POC (E) 1-1/4"M~-,...-

.l ~ •

V:\1842\active\184200751\civil\drawings\C1_0_0.dwg, 11/19/201910:23:36 AM, ijosifek

\ i

I

FIRE PROTECT~

SYSTEM POC i '

SEE DWG P2.0.0

I .

\ I \ I l\ ' \

GENERAL NOTES

1.

2.

REFER TO SHEET CO.O FOR CIVIL ABBREVIATIONS, NOTES AND SYMBOLS.

THE UNDERLYING SCANNED IMAGES OF ORIGINAL AS-BUILT SITE

DRAWINGS CONTAIN ADDITIONAL INFORMATION ABOUT THE PROJECT

SITE THAT IS FOR REFERENCE ONLY. OVERLAID NEW CONTENT

SPECIFIES NEW WORK THAT IS PART OF THE CURRENT PROJECT AND

CONTRACT, ; · .. ··.

I i i • \

I ' I

• . "•.J

' ! f

' !' I I . .

NOTE: SHEET C1 .0.0 IS PART OF THE

SYNTHETIC NATURAL GAS PLANT DRAWING

SET AND COVERS THE SAME AREA AS C1.19

AS SHOWN ON THE KEY PLAN

KEY PLAN ' ., ·-~

' ' 1--~-------~-------1 ' i

' I .

' t ;

I .

C1.11 tl'.

w z

[Z Cl

8~ en N

I

:z

C

...I (.) -. 10 ,.._ N .,,.

co -tl'.

LU

i Cl

TBB

California Department of Corrections and Rehabiliation (CDCR) Plans

Bid Number C5612927-D Re-Bid 1 Exhibit A-2

N

1 o· -o"

8' HIGH CHAIN LINK FENCE

WI BARRIER WIRES (TYP.)

62'-10"

15' -0" 15' -0" 9' -8"

. 0.2%

SITE GRADING

SCALE: N.TS.

5' J'

15'

6" AB

(TYP)

58'

CONG TANK FOUNDATION,

SEE STRUCTURAL DETAIL

@·, SITE GRADING

~ SCALE: N.T.S.

'20/

X

130.6

AB

1 ______ ,

30.000 GALLON~'\".~.;:::><:;::::--, 5"-0"

. TANK. ii;;

\--=--_-_=--:_:l @-y\--

GENERAL NOTES

I I

NEW GRADE, FILL

TOE OF SLOPE

(SEE NOTE 5)

15' -Q"

·•.-· f '.

6" AB

1. SEE PLUMBING DRAWINGS FOR SYNTHETIC NATURAL GAS PIPING AND EQUIPMENT PLAN AND DETAILS.

8'-2"' 5'-0"

6"AB

(TYP)

8'

6" CONG/ 6' AB --'

8' HIGH CHAIN LINK FENCE

WI BARRIER WIRES (TYP.)

<.·1

12' (E)EP

·1 I

. 2.0,; I

(E~ ~~R~ICE ROAO 7

r-- 8' HIGH CHAIN LINK FENCE

/ _ ;':R~:E~

' 130.42 .

AB

2. ALL CONSTRUCTION SHALL CONFORM TO. AT A MINIMUM, THE CBC 2016, CMC 2016, CFC 2016 AND ALL APPLICABLE ADA CODES.

3. REFER TO SHEET CO.O FOR CIVIL ABBREVIATIONS. NOTES AND SYMBOLS.

4. SEE SHEET E2.0.0 FOR BOLLARD DETAIL 4/E2.0.0 AND BOLLARD PLACEMENT.

5. HYDROSEED WITH NATIVE OR NONINVASIVE SPECIES APPROPRIATE TO THAT SPECIFIC LOCATION TO INACTIVE CONSTRUCTION AREAS (PREVIOUSLY GRADED AREAS INACTIVE FOR 10 DAYS OR MORE). HYDROSEE MIX TO BE APPROVED BY THE ENGINEER.

. //:7 / I '

,. ; · ·•,if' UJ ciwo ,...< / iN5 N. (\, i i' ,_.._ l i ! 1' / I ' •• i ! {

- r'-J_ :, I ;i st n.

Ii I J NO ' I .-

/ /jy, ! 1" W I i/ w

I I I /; ~ i--

/ /1 ;· I 11ro o Jill_ ow

NO

,- I-

I i:/ ' I . I j ;

l / ;.: '

'v (\j

!t

I

' /I

[ill]

(J') ()J ·o

~z ,-0

X

SCALE:

I n i rn I st i.J ~1 I

. ' I I I I I

I I I !

I 1 i :

I , t / I

/ .ro ~ / ,/ ✓/ ciCL

I r .- ~o ! i (0 .-1- , I N .

·/ ci CL : r00 I __ ,_

. I I I

1 I ! : . k

- - ··----- -·---- _, ..... - - --·- ----- ----- i

' 7 .-, -- '

- ' --. ' -. • F ✓ -- -

PIPING BELOW GROUND

· · SEE PLUMBING PLAN

V) ·o -z ::, (.'.)

X

4" CHAIN LINK SWING GATE W/

BARRIER WIRES @ ~

C2.6.0 vi§;! .

-Cl

(j \ 0.. ·.

- ,., Q

I -~·· j.

~\ I

C)

I I

I C)

I I g

I I I I

··1

42'-4" __:X::,___ __ ___;~--1

131.)

MATC1 EX

___ i __ ~_j I

, o

C)

-----(E) GAS SERVICE UNDER

GRADE FROM UTILITY.

(E) UTtTY POLE AND GUY WIRE

\ PROTE\T IN PLACE

I (l.

i

Q

_\1\ /1 .

(E) FENCE

Q.

I N u

"' '-' z i u

N ...

00 -

I r----(E) GAS PRY

□ \ &METER :r------WL\-( CATHODIC

!--- 8' HIGH CHAIN LINK FENCE

WI BARRIER WIRES (TYP.)

VARIES 42' -4" TO 44' -0"

GB

.VARIES VARIES.,

132.6

MATCH EX

EXISTING FENCE --

MATCH EXISTING GRADE

(SEE PlJ\N) SEE PlAN)

- .~~~!""!~.,.,,,..,~~:,-i\~.,~c-~, !"/~. ~Y!s.~~~"';'c~~~"i'.":,.(z,"',~""''\'• ~~~~~":l"f!:3~':!.!", ~~.!!',;.,,'s', ~7~·

EXISTING GROUND 6' AB

(TYP)

SITE GRADING

SCALE: N.T.S.

P OTECTION PANEL,

S E SHEET E1.19

-WAY BYPASS

ALVE ASSEMBLY,

EE SHEET P2.0.0

KEY PLAN

APPROVALS

CALIFORNIA DEPARTMENT OF CORRECTIONS

AND REHABILITATION ACCESS COMPLIANCE

REVIEW

APPROVAL OF THIS PLAN DOES NOT AUTHORIZE OR

APPROVE ANY OMISSION OR DEVIATION FROM THE

APPLICABLE REGULATIONS.

TRACKING NUMBER: lib! DATE: l·'"T·Zou:>

REVIEWER: ~ 44¥4'1I.

CALIFOR~\;RE MARSHAL.

APPROVED

FIRE AND PANIC ONLY

0:: . w z Q en w z '.3 Q.

0:: w i iii

0 -' !

w..J (.)~"'

~en~ eno fll 1---f:;,

- z ~ '-q~ g ..Joo~ ...... a: <...-i .. .. a.. Cl co !s ~ .9-...., ..,. O'> . ,;:I z wc5co · t- _<D ~ ~~~ ~ ~ ?i 0 >"en >- <t o w " >- OU Lll u :r: ~fisui ·ffi g ~ w Z.,:....J ~ C

~ ~ ~ ~ ~ .,0.. .!

a.. -oo · - -~ ~o<C tn ~ \ '"'- oN> a ... ........ ___ ..__..._ .... _~

APPROVAL or THIS Pl.All DOES NOT AUTHORIZE SHEET NUMBER O

OR APPROVE ANY OMISSION OR DEVIATION FROM ;ij

THE APPLICABLE REGULATIONS. FINAL APPROVAL :;-

IS SUBJECT TO FIELD INSPECTION. ONE SET or C 2· Q Q ~ APPROVED PLANS SHALL BE AVAILABLE AT TliE j

PROJECT SITE AT IILL TIMES. ■ ■ N :; ~L _________________________________________________________________________________________________________________________________ L_·~RE~v~1t:w~to~~:'~#~::::S~J=A=N=0=2::::::W:20:._.~o:F_!*_~s:H:E:E~Ts:Jt

TBB

California Department of Corrections and Rehabiliation (CDCR) Plans

Bid Number C5612927-D Re-Bid 1 co 0 .. --co -0 N

N co

PERMANENTLY WELD

(E) M.AN HOLE COVER

(E) STEAM UG PIPING

TO BE ABANDON~D

IN PLACE

DEMOLISH ALL VALVES FLOATS,

PIPING AND ACCESORIES

DEMOLISH (E) VENTS

AND REPAIR EXISTING

MANHOLE COVER.

COMPLETELY FILL PIT

Z,,,7,W~WITH SAND

CAP PIPING AT PENETRATION

NATIVE SAND, IMPORTED LOW EXPANSION

POTENTIAL MATERIAL OR CLASS 2 AB

AC PAVING TO MATCH EXIST THICKNESS

ADD OVERLAY

ENTIRE WIDTH .

IN EXISTING

PAVED AREAS

z Q !- (/) C

~ (.) V> :;, <( ..J"' L,J

ma. zb

:. ::, z

SAWCUT

CLASS2AB 8 L,J

z 0 .... "' () 0 <(

0, a.

NOTES:

t() i!:

9"THICK MIN 3/4" x 1-112" _../

CRUSHED ROCK

WRAPPED WITH

GEOTEXTILE FABRIC,

12" MINIMUM WRAP

OVERLAP, SEE NOTE 2

INSIDE OUTSIDE

ROADWAY ROADWAY

9"MIN

(TYP)

PIPE 00+24"

DETECTABLE MARKING TAPE

18" DEEP IN NON ROAD AREA,

24" DEEP IN ROAD AREAS

TRENCH EXCAVATION

BACKFILL MATERIAL

CAP PIPING AT PENETRATION

1. TRENCH SHEILD SHALL NOT DISTURB BEDDING BELOW TOP OF PIPE, TRENCH SHALL BE "BENCHED"

FOR SHEILD.

@ ~~:1~:L STEAM PIT DEMOLITION

90e BEND ti' g ff p,:., '<' it & "' ref &

6" 11 1/4° 1,108 1 1 22 112· 2,207' 1 2 45• 4,328 2 3 90• 7,996 2 4

PLUG 5655 2 3

8"

I:

45° BEND

REACTION BEARING AREAS FOR

HORIZONTAL WATER PIPE BENDS

BASED ON TEST PRESSURE OF 200psi

1 1 1 1 2 1 1 1 3 1 1 2 5 1 1 2 4 1 1 2

TEE INTERSECTION

2 1 3 1 5 1 8 1

2. TO BE USED WHERE TRENCH BOTTOMS ARE DISTURBED BY CONTRACTOR'S TRENCHING OR PIPE

INSTALLATION PROCEDURES OR WHERE EXCAVATION OCCURS BELOW GROUND WATER TABLE.

NOTES:

1. REACTION BEARING AREAS ARE IN

SQUARE FEET MEASURED IN AVERTlCAL

PLANE IN THE TRENCH SIDE AT AN

ANGLE OF 90' TO THE THRUST VECTOR.

2. CONCRETE SHALL BE 2500psi OR CLASS

C CONCRETE.

3. CONCRETE SHALL NOT CONTACT BOLTS,

GLANDS OR ENDS OF MJ FITTINGS.

4. TRENCHES SHALL CONFORM TO STANDARD

DETNL. (SEE DETAIL THIS SHEEn.

5. ALL BENDS AND INTERSECTIONS SHALL

HAVE CONCRETE THRUST BLOCKING.

PROVIDE POLYETHYLENE PLASTIC SHEET

BETWEEN THRUST BLOCK AND FITTING.

6. SEE e•, 90" BEND VALVE FOR HYDRANTS

FOR ADDITIONAL SAFETY FACTOR.

TYPICAL PIPE TRENCH SECTION

SCALE: NTS

AC OR CONG

BROOKS METER BOX

W / H20 COYER OR

EQUAL SIZE AS REQD

PIPE RISER SHALl

BE 4", UNLESS

NOTED OTHERWISE

AB OR DIRT

' g•

·. i' 11 1, 11 l;

24"x36~ QUAZITE UTILITY BOX, PART NO. PG2436B818 OR

APPROVED EQUAL. STACK BOXES

TO OBTAINED REQUIRED DEPTH.

QUAZITE TRAFFIC BEARING COVER,

PART NO. PG2436HA0009

OR APPROVED EQUAL.

1WO WAY 4" x 2-1/2~

FIRE DEPT. CONNECTION,

THREADS TO MEET BASE

STANDARDS. PAINTFED. ·

COLOR #20050.

!---,,+--COVER SLEEVE. PAINT

~ - FED. COLOR #20050.

~-,-- IDENTIFICATION PLATE

.. ,',,RADE ,, __ """""' """'"" '""""' '"' .• ,, .. '"""""""'

•• • • .. .. .J •• '

LANGED

FITTING

MECHANICAL

COUPLING7

36n SQUARE x 6" THICK

CONCRETE GRADE PAD

REINFORCED WI

6x6xW1 .2xW1 .2 W.W.F ..

p.,-.;,.;,=-4• MECHANICAL

i. MEGALUG

RETAINING GLAND

18" MIN#67 STONE

THRUST BLOCKING, (SEE

DETAIL THIS SHEET).

FM-UL LISTED

SWING CHECK VALVE

W/ BALL DRIP

. ' 90', BENO - .

·· DUCTILE IRON

. •t THR~:;:~:::~:~~:~ING

DETAIL THIS SHEET).

FIRE DEPARTMENT CONNECTION

GFCI RECEPTACI.

FOR HEATER

ANCliORAll!GLES-\ TO CoNCRET~ \ SlAS TVP!CAL SUPPUt'D WiUNIT fROMWATt':R

SUPPLY MAIN

6"-1"

PROI/IOE INSUI.AT£D ENC.l.OSURE FOR

/!,I3CJVC.. GROUND BACK FLOW PREVENTER.

ENCLOSURE SHAU. BE CONSTRUCTED Of STUCCO AUJt.!INUM/INSULATION SANDWICH PANELS, 8ACl<FLOW .PREVENTER · SHALL BE

ACCESSIBLE THROUGH DOORS OR

REM0VA13LE PANELS: ENct.,OSURE; To EIE

EQUIPPED W/ MANUFACTURER'S STANDARD

HEATER PACKAGE -, 1500W/120V/!•;

COORDINATE CONNECTION -W/ E.C ••

RO\IIOE RPZ STYLE BACK FLOW

PREVENTER ASSEMBLY AS INOICATEO, _ WITH

SPRING CHECKS, O.S.&Y. GATE V'AL\iES, AND TEST COCKS. ENCLOSURE TO HAVE

OPENING TO PIPE REI..IEF VALVE DRAIN -TO

GAAOE OUTSIDE ENCLOSURE. Pi:1-0VIOE AIR ~ nmNG FOR REI..IEF VAL.'tl'E" ORAIN.

· /iROVIOE S4"X78"X6• TI·UCK CONCRETE ' SLAB Win{ 12" TURNED DOWN EOOE, - --

RE-!NFORCE WITH W.W.F. MAT. SLAB TO -

. SE 'J~ A80v'E ;..""tJRROU"NDiNG GRAW.

NOTE: SIZE OF PAO MAY VARY WITH

ENCLOSlJRE MANUFACT\JREft

TWO 3/i' CONDUITS FOR Al.ARMS ~ND

KEATER. -

NOTES:

6'-1"

1. LOCATION OF STREET TAP Nro BACK Fl.OW PREVENiER SHA1.L BE COORDINAlID W/ WATER UTIUTY. CONJAACTOR SIW.L PAY WAlER TAP· FEES.

FIRE l'fiOTECTlON 2. PROVIDE TAMPER SWITCl-lES. ON BOTH OS&Y VALVES. At.SQ SUPl'lYTOBLOO. PRCN1DE A¾• CONDUIT fOR ALARM WIRING TO 8LOO F"ACP.

SPRlNK!.l:RSYSTlJ! 3. AU. PIPING SHALL eE Cl.ASS 51 C£MOlT UNEO DUCTILE

'"""· 4. PIPING FROM -UNDERGROUND MAIN -TO 8ACKf'l.OW PREV£NTER SHALL BE MECHANICAL JOINT DUCTlLE IRON W/ MEGALUGS OR RESlltA»-IED . JOINT OIJCTII..E IRON. PROVIDE TliRUST BLOCKS AT UNDERGROI.INI) a80WS.

FIRE SUPPRESSION BACKFLOW PREVENTER ENCLOSURE DETAIL

SCALE: 1f2"" 1'-0"

FIRE SUPPRESSION

BACKFLOW PREVENTER

SCALE: NTS SCALE: NTS

! 5" MIN / 8" MAX

CALDER CPLG & PLUG

FOR NON-PRESSURE

LINES. BLIND FLANGE

FOR PRESSURE LINES

PLACE BOX ON

BRICKS ALL

AROUND

......... s

A

30"

5•

VARIES

A

NOTES:

1. THIS INSTAUATION SHALL BE USED ON

EXISTING MANHOLES ONLY WHERE THE

DIFFERENCE IN ELEVATION BETWEEN THE

TOP OF THE OUTLET PIPE AND THE

INVERT OF THE FEEDER OR CCLLECTOR

SEWER EXCEEDS 24".

2. BAND COUPLER SHALL BE A MISSION

SHIELDED TRANSITION COUPLER, MODEL

NUMBER MR02-44 OR APPROVED EQUAL

BAND SHALL HAVE A MINIMUM OF 3

LOCKING BAND STRAPS.

3. PVC OR ABS PIPE SHALL BE USED

INSIDE MANHOLE.

EXISTING

MANHOLE

OPEN END

(TEE TOBE

CUT AT 45°)

WATER $EENOTE2 '

TIGHT SEAL

SEENOTE3

' N

I ' "' 0 I

' "' I

111/4° 1,970 1 1 2 1 1 22 1/2° 3,922 1 2 3 1 1

1 2 1 1 4 1

7. THRUST BLOCK FOR TEE INTERSECTION

SAME AS FOR 90" BEND.

MAINLIN 45" LONG RADIUS

BEND z

STAINLESS STELL

BANOS ANCHORED 24" MIN

45• 7,694 2 4 5 1 1 2 8 1 90" 14,215 4 8 9 2 2 4 15 2

PLUG 10 053 3 5 6 2 2 3 10 1

10" 111/4° 4,433 2 3 3 1 1 2 5 1 22 112· 8,826 3 5 6 2 2 3 9 1 45" 17,312 5 9 11 3 3 5 18 2

MAINLINE

rLoW I SLOPE goo 31 ,983 8 16 19 4 4 8 32 4

PLUG 22 619 6 12 14 3 3 6 23 3

@ ?c~~~~ARD THRUST BLOCKING CLEANOUT

SCALE: NTS

WYE OR BEND

IF AT END OF

LINE

• WITH STAINLESS

60"

;;; STELL BOLTS TO

WALL 24" O.C. (TWO

BANDS MIN.)

SECTIONA•A

t r i'.-¼:~

SEE NOTE 6

SECTION B-B

INSIDE SANITARY SEWER

@ ~A~,O~s CONNECTION

APPROVALS

CALIFORNIA DEPARTMENT OF CORRECTIONS

AND REHABILITATION ACCESS COMPLIANCE

REVIEW

APPROVAL OF THIS PLAN DOES NOT AUTHORIZE OR

APPROVE ANY OMISSION OR DEVIATION FROM THE

APPLICABLE REGULATIONS.

TRACKING NUMBER: -~/-7-U,20

REVIEWER: 4#/111 ;,

CALIF'ORNIA STATE FIRE MARSHAL

APPROVED

FIRE AND PANIC ONLY

APPROVAL OF THIS PLAN DOES NOT AUTHORIZE

OR APPROVE ANY OMISSION OR DEVIATION FROM

THE APPLICABLE REGULATIONS. FINAL APPROVAL

IS SUBJECT TO FIELD INSPECTION. ONE SET OF

APPROVED PLANS SHALL BE AVAILABLE AT THE

PROJECT ITE AT ALL TIMES.

REVIEWED BY:

i ~ ~ Q l!!

z (/) ::c z > u :z

0 a ~ s I- = z (I) w c:, ~ co w <C (!) Cl ::i:: <C :z LU z ~ 0:: <C en

<C Cl :::r;; c:, z z a :z: (/)

0:: <C z <C LIJ 0 <C en (.)

LL (/) ll.l

::J z z u <C 0 0 5':: w u I- I- ll.l (/)

LL u (.) en z 0 w :::> _..J (!) 0:: a::: ~ w 0:: I- Cf)

~ 0 (/) :z w (.) z ll.l Cl

0 :a;;

(/) LL :z

0 (.) 0 I- -a:::

(!) -z z> w _z ~ z u.J

!i: z Cl <C ~ if --' CL :z:

w >- <.9 a I- en

::J LU

c:, <C

LL

"' <O

·2 "' ·-J~ 0"' o ...

0, ~ ~ " _, ·- - < -; ;j 0 .,, - " - 0 m~g co "'i' ~ oO-

t) =a ii <O (.() :-t u a E ..-..-c::

0, a, " *Ue:! "ti .s:28~ -xi Cl) I() (/) CJ) ;! tE • w t;;

(J) a.

z 0 a::

J::

w

:5 a.

w a::

0 z :5 (J) z a:: .

a::

w z (J) w Cl a_ 0 "' w<"' I- 0 f:8 < a:: "' t;; 5 c3 < 0 .

Z CD~ a::: <( _,J ow-

u. [l_ ~

::JO(.)

UN>

I-w w ::c

II)

ti) ..I

Cl

Cl

• -I

IO

(I) z

0::

Cl

_J

-It) .

I", 0 .

N ...,. .

00 -w j::

N ...,.

!3 00 Lit 'II""'

0 . -.

'1>

"' c1;

;j z ..

"' -0 N

<6 -et: w a:, I-

SHEET NUMBER

C6.1

OF # SHEETS

·a :g E g ---

53- " ~ .. • 0 -:,.

"' J, '" v "' / • .> -u '" v

TBB

California Department of Corrections and Rehabiliation (CDCR) Plans

Bid Number C5612927-D Re-Bid 1 Exhibit A-2 matthew.vanatta Rectangle matthew.vanatta Rectangle

-r a..

0 ..., N

N

If';/ / , .. /! ;;-I / / l/ I I ,4

!/ / / ;J f / / / f

!111 f I I I I

I I I , / / i

I / /

/ rv-.. :

I I , /

,. I I / I /;>/~

11 l/1 , f I I

I / I /_ I / I 1 < , , '

I I I i I ·,-~ i / /1 / / .' / I / / I

' // if r1 I I I I

I

I I I

I

I

If ,/ /-- / / // --- - - -------------------~, 2 5- -------~-----

-- __ , ___ -·-·- --- ; L- '

I I / --- / ' -I I I I/.: ==-----_ ----- -=-:::::::::_:11-_;;_;0IJ.:·:_--____ --____ 1_::2--=9--=---=--=--------

, I; 1//r v)

(E) GRADE ------

I I I I

I' / / , I , , /;

• I ' I ( fi , r , • _ r

1 I I

I I I I I I I I I/ I I ! I /1

I i I I ,/ I / 1

I ! ! I

• 1 ! / Ii

I I I I 1/ I I i I I Ii I / i I I I I

I / . I i ' i I I I ! !

i I ' , i I' I I I I I

I Ii I I I I I ! I :

I

I i

: I

I I I I 1

I i 1

11 I

I I I i 1 Ii I i 11

I ' I I r

' I

I I I

I I I r

"/ / \ ,I -~ ( )

-- MANUAL RELEASE / / _

STATION / - /

r-1- 8" FIRE LINE REFER TO

CIVIL DWG FOR CONT.

I

52'-10"

OIL SEPARATOR

1" DRAINS TO

DRYWELL

CONC. PAD (TYP) (

- 1~' I _, AM

DRY WELL

g "ti G)

I la

GENERAL NOTES

1. DISTANCE AROUND AND BETWEEN STORAGE TANKS SHALL BE PER NFPA 58 SECTION

6.3.1. AND CFC TABLE 6104.3.

2. PROVIDE KNOX BOX FOR THE PROPOSED 8 FT FENCE AND GATES FOR EMERGENCY

INGRESS TO THE SITE.

3. PROVIDE FIRE EXTINGUISHER WITH MINIMUM 18 POUND B:C DRY CHEMICAL

EXTINGUISHER. 4A:40B:C

4. REFER TO SHEET P2.3.0 FOR EQUIPMENT SCHEDULE AND SHEET P2.5.0 FOR PIPING

5.

6, 7.

8.

DIAGRAM AND SIZES.

NOT USED

REFER TO SHEET P2.5.0 FOR SIGNAGE DETAILS.

SEE DETAIL 7, SHEET P2.6.0 FOR SIGN POST INSTALLATION.

REFER TO SHEET P0.0 FOR PLUMBING ABBREVIATIONS, NOTES AND SYMBOLS.

- ---------- 9. SEE SHEET E2.0.0 FOR BOLLARD DETAIL 4/E2.0.0 AND BOLLARD PLACEMENT.

(E) GAS SERVICE UNDER

GRADE FROM UTILITY. ---~ I

(E) FENCE J

(E) FENCE

-I _ J I

I ---- .:--.,.--1,-\

KEY PLAN

N

APPROVALS

- CALIFORNIA DEPARTMENT OF CORRECTIONS

AND REHABILITATION ACCESS COMPLIANCE

REVIEW

APPROVAL OF THIS PLAN DOES NOT AUTHORIZE OR

APPROVE ANY OMISSION OR DEVIATION FROt.t THE

APPLICABLE REGULATIONS.

TRACKING NUMBER: 1114\ - DATE: f·1·2<>Z<>

REVIEWER: ~ ~'ftf

CALIFORNIA STATE FIRE MARSHAL

APPROVED

FIRE AND PANIC ONLY

APPROVAL or THIS PLAN DOES NOT AUTHORIZE

OR APPROVE ANY OMISSION OR DEVIATION FROM

THE APPLICABLE REGULATIONS. f'lNAL APPROVAL IS SUBJECT TO FIELD INSPECTION. ONE SET or

APPROVED PLANS SHALL BE AVAILABLE AT THE

PROJECT SITE AT ALL TIMES.

REVIEWED BY:

_....-::r.~N O 2 2020

"' ~ " z z

! i!i li5 z i "Ill o Ill "" " -"., zi! "'~ ;a ii! ;"' " ~ ; .!, "' w

" "' §~ ~i u a, ..a C ta ..a

V)

::;; z

::i w I-

0 "' i:i "' 0.. z

0 0 0 "' 1i: ..I (.) a.. Cl <O z w <( 0)

..... 0 f8 ~ <( 0:: 0)

0 t; >- <( Cl U >-::c: <( 0 .

-a,W w z cii ..I 0 0:: ..I

::i 0 0.. >

LL. 0 <(

0..

~oU w

0:: u N :;

Y,l z !l i!i ism "-ii !il .!, z 0.

w I-iii

CJ

:ii!:

m ..J a..

CJ

..J

!t z Iii ::c I-z

"' " z !l i!i .,_ 0 ::l "-1!

i~ tO -w I-

N

,:I ...,.

;;!tO ... _ 0 .. ·-<> >

0 z I-w --, 0:: a..

w I-z

0::

i Cl

"' c';

..l, -..

0 z ..

"' -0

"' <D

0::

w

ID -

0 ..

!c

SHEET NUMBER

P2.0.0

OF # SHEETS

m C

" • u

E

N N ci -m

"-m m , u □, o, N m .S • 0 C

" 0 c 0 •

Ci N " 0

N

TBB

California Department of Corrections and Rehabiliation (CDCR) Plans

Bid Number C5612927-D Re-Bid 1 r a, -0 - N

N -

ID# IMAGE SPECIFICATION GENERAL NOTES

1. REFER TO SHEET PO.O FOR PLUMBING ABBREVIATIONS, NOTES AND SYMBOLS.

f(QANGE~

MATERIAL: 0.40" ALUMINUM

SAFETYSIGN.COM ITEM#: J1630

CODE REFERENCE: 2014 NFPA 58

SECTION 5.2.8.4 (2)

NATURAL GAS TO SITE

/ DISTRIBUTION SYSTEM

BUILDING BRANCH LINE

(TYP)

PRESSURE RELIEF--------------!:'.!

VALVE (TYP)

AIR COMPRESSOR -460V/3PHl60HZ

AIR COMPRESSOR

CONTROL PANEL

MULTI-PORT PRESSURE

::,,--- RELIEF VALVES, SPRING

LOADED (TYP)

ROTARY GAUGE

D-1

V

N-1

N-2

'NO SMOKING

FLAMMABLE GAS

8 i ·:-r:;·

Fl E E X T I N G u I s H E R

V

2 0

8 +

I

COLORS: RED "DANGER" SYMBOL, WHITE

BACKGROUND, BLACK LETTERING

MOUNTING DETAILS: BOLTED

FURNISHED BY: CONTRACTOR

INSTALLED BY: CONTRACTOR

MATERIAL: 0.40" ALUMINUM

GRAINGER ITEM #: 9WLM4

CODE REFERENCE: OSHA 29 CFR

1910.157(C)(1)

COLORS: WHITE LETTERS ON RED

BACKGROUND

MOUNTING DETAILS: BOLTED

FURNISHED BY: CONTRACTOR

INSTALLED BY: CONTRACTOR

MATERIAL: OUTDOOR VINYL

SAFETYSIGN ITEM #: M3357

CODE REFERENCE: 2012 NFPA 704

SECTION 4.1.1

COLORS: BLACK TEXT; BACKGROUNDS:

2:BLUE, 4:RED, O:YELLOW

MOUNTING DETAILS:

FURNISHED BY: CONTRACTOR

INSTALLED BY: CONTRACTOR

I---Oo(J-L--1-J SHUT-OFF VALVE --, (TYP)

0..

[ii" -

FLARE STACK- -----------1

WI CAPACITY= 69,000 MMBTUH

PILOT

COUPLING

(POL YETHELENE

TO STEEL) 1------ 114"

PRESSURE GAUGE ~

(TYP) . ~

- - 120Vl1PHl60HZ

, ---- FLARE STACK CONTROL

PANEL

o--- 3"

PRESSURE SWITCH

--+- ISOLATION

FLANGE

,=~---- BLIND FLANGES

~- SHUT-OFF

VALVE

1------ 3" FLARE STACK

BUTTERFLY VAVE WI

,,,.-J1-- PNEUMATIC ACTUATOR

(FAIL CLOSED)

NC

SURGE TANK

ffi

... PRESSURE RELIEF

VALVE

PRESSURE REGULATOR

VALVE (SET@ 35 PSIG)

PRESSURE SENSING PORT

ffi LIQUID LEVEU

PRESSURE GAUGE .___,,.._ ____ _.,

REFRIGERANT -460Vl3PH/60~HZ DRYER ___ _j

UNION

FLOAT GAUGE

(TYP)

t---- FILTER (TYP)

.,..._.., TO DRYWELL

THERMOMETER

(TYP)

AIR RECEIVER

ffi i----2"

CONDENSATE

OIL-WATER

SEPARATOR

~ STRAINER SOLENOID VAL VE

/ (TYP)

SOLENOID VA. WI

CYCLE TIMER

-120V/1PH/50HZ

~---,---1 TO DRYWELL

~ CONDENSATE DRAIN

I - -120Vl1PHl60HZ

I VAPORIZER -----

CONTROL PANEL

I GLYCOLWATERFILLW/ \

CAP

I MIXER

DIFFERENTIAL BYPASS VALVE --

CHECK VALVE (TYP) -

GLOBE VALVEWI ~

HYDROSTATIC RELIEF

r -460V/3PH/60HZ

I I I

I CONTROL PANEL ,------------,

(TYP)

460Vl3PHl60HZ

PUMP If\

NC \J:::,7

MIXER

460Vl3PH/60HZ ITO PUMP STARTER!

I I

VAPORIZER

ffi

SEE DETAIL 2/P2.5.0

(TYP)

30,000 GALLON

LPG STORAGE TANK

~ INTERNAL VALVE WI

PNEUMATIC ACTUATOR

~ SEE DETAIL 9 / P2.6.0 (TYP)

, ~ GLOBEVALVEW/

-~ HYDROSTATIC RELIEF

(TYP)

UNION (TYP)

FLEX. CONN. (TYP)

1-.-t~ --t-----t---------t- LIQUID WITHDRAW

1------t-----if---------t- LIQUID FILL

-~-2"

N-3

~MERGENCY SHUT-OFF

VALVE FOR VAPOR

RETURN

MATERIAL: 0.40" ALUMINUM

GRAINGER ITEM #: CUSTOM

CODE REFERENCE: 2014 NFPA 58

SECTION 6.12.10(1)

COLORS: RED LETTER ON WHITE

BACKGROUND

5• l

SPECIFIC GRAVITY TEST

PORT

GLOBE VALVE W/

HYDROSTATIC RELIEF

2" LPG VAPOR GLOBE VALVE WI

HYDROSTATIC RELIEF ,_____---+----+-- VAPOR RETURN

N-4 i V + -

EMERGENCY

FUEL

SHUTOFF , ________ _

SIGNAGE DETAIL

SCALE: NONE

MOUNTING DETAILS: BOLTED

FURNISHED BY: CONTRACTOR

INSTALLED BY: CONTRACTOR

MATERIAL: 0.40" ALUMINUM

GRAINGER ITEM #: 3NY30

CODE REFERENCE: 2014 NFPA 58

SECTION 6.12.10(1)

COLORS: RED LETTER ON WHITE

BACKGROUND

MOUNTING DETAILS: BOLTED

FURNISHED BY: CONTRACTOR

INSTALLED BY: CONTRACTOR

DRAIN LU

THREE-WAY BYPASS VALVE

(NORMAL POSITION IS WHEN

SYNTHETIC GAS IS NOT BEING USED)

SHUT-OFF

VALVE

PRESSURE REGULATOR

VALVE

4"

ISOLATION FLANGE PRESSURE GAUGE (TYP)~

COUPLING

(POLYETHYLENE TO STEEL)

SHUT-OFF VALVE (TYP) ~

FLEX (TYP) - -----

UNION (TYP) - ------~~

ISOLATION FLANGE

COUPLING

(POLYETHYLENE TO STEEL)

NITROGEN STORAGE

CYLINDERS

LU

GLYCOL WATER DRAIN J

1/2" STAINLESS STEEL

PNEUMATIC TUBING ~

112" NITROGEN TUBING

u::

N --' W

I ~~ ~ (J) (J)

0.. ::;; ::;;

/ PRESSURE REGULATOR

STRAINER

(TYP)

NITROGEN TUBING

SEISMIC DETECTION SYSTEM

MOUNTED ON CONCRETE PAD

(NORMAL POSITION IS WHEN

SEISMIC VALVE IS NOT

ACTIVATED, NORMAL

OPERATING CONDITIONS.)

ffi

NO

COM

THREE-WAY BYPASS SOLENOID

VALVE (NORMAL POSITION IS

WHEN ENERGIZED)

THREE-WAY BYPASS

SOLENOID VALVE SWITCH --~

I I

ON

OFF

ffi

~ PUMP BYPASS

BACK PRESSURE REGULA TOR

PNEUMATIC ACTUATOR -~

MANIFOLD (TYP)

30,000 GALLON

LPG STORAGE TANK

2•--1---- ---i

1-114" - --, ANGLE VALVE - ------f

EMERGENCY SHUT-OFF ~

VALVE ~

1/ ANGLE VALVE WI

HYDROSTATIC

RELIEF

/ VALVE

1----tHDIO--{XI--L--fr ¼ -M- - -(E)MPG- - - -< GAS SERVICE 110,933 CFH 1 t 0

~ UNION (TYP)

~ BACK CHECK

VALVE

-~na~ i.N~.

~41~

Pttitm't~ ~ Alt '

~IIU!II-~ v_-~ ~ ~ r~ Vii\OON ~

~r~ ~---00 2,t\f

~ Air UM

~6""Une

Eloollill~

AC 110 V 60 Hz (USA) Grawfume1~ 1------ GraviBlend™-3 Vent

AC 220 V 50 Hz (Export)

Power Suppiy. PLC. PCV --·-------- Operator Interface, Terminal Str ip (inst.;lll in hon-hazardous area) I·

---------- - - --- ------- -~p1 · p f ... .,,- ___.._ =-' _ , _ _ __ ·-• _ _ -·- -·· _ ~ -· _ ~-- .,_,. " .cJI. os,on roo I 1·- - '"- - ·~· -· ·•·• -- .. Elecirical Box I - - . L ___ ___, LPG VaporlnleC I I ' 2" • 300# Flange_ ,.' .

- ----IL)--,---'-----~~s...l'~ 7-- 7~::::::;:r-,---:~fir--=fj.T-+ . y' 7 -r -r =""" l .- PCV I I

I I l

-- l. 1l I I g - l j

II .,..,...,"-

. .,. f'b,;:~

1'9 ,.._, . DIM~YM

~ -...-,.,,, bl .,,__

D """"" 1 ..... ,,,.., ... .._

PGA ·

1. I l I I l

PCV

I J_ lr-E~-,___,__..,..c....• ·---1· 1. i \J'!:>C---.. 11 -r

I Mli<.d Ga< Ornlei !

~!t~9} .i

POM-40'. .,. I

PQl,l:6P; '6'' l l I ! Blenders wilti discharge pressures above 80 • psi(5,6ba-f are equipped with a•CQotrol valve !

_ _ _ __ 1::rn~a.i~d~in~:a!ct~~~gu!;Of _: _____ _.. _ ,_ __ .-= _ ~~ ·~• ~~ ,_ _ ~ --= _J

AIR BLEND MIXER DIAGRAM

SCALE: NONE

15 PSI NATURAL GAS

SITE DISTRIBUTION SYSTEM

SEISMIC VALVE--~

GAS SERVICE PROVIDED BY THE GAS EMERGENCY SHUT-OFF

STATION COMPANY

, 1 '

1J>2.s.o.., 0 0 0 0 120V, 1PH, 60 Hz - - - - - -- - - - - -- - - - -

EMERGENCY PUSHBUTTON EMERGENCY PUSHBUTTON EMERGENCY PUSHBUTTON EMERGENCY PUSHBUTTON

ALARM STATION #4 ALARM STATION #3 ALARM STATION #1 ALARM STATION #2

EXCESS FLOW VALVE

HOSE COUPLING ~

WI 2-114" ACME CAP_/

"Y" STRAINER

------ HOSE COUPLING

WI 3-114" ACME CAP

LPG TRUCK UNLOADING STATION

STANDBY SYSTEM (SYNTHETIC NATURAL GAS)

SCALE: NONE

NOTES:

1. REGULATORS FOR OUTDOOR INSTALLATION ARE

REQUIRED TO BE DESIGNED, INSTALLED, OR

PROTECTED SO THEIR OPERATION WILL NOT BE

AFFECTED BY THE ELEMENTS AS NOTED ON

NFPA 58 - 6.8.1.5

2.

3.

4.

5.

PIPING AND TUBING SHALL BE IDENTIFIED IN

ACCORDANCE WITHASME A13.1 TO INDICATE THE

MATERIAL CONVEYED AS REQUIRED BY CFC

5003.2.2.1 (2)

PROVIDE MARKING ON VAPORIZER CONFORMING

TO ASME CODE. E.G. MAXIMUM VAPORIZING

CAPACITY IN GALLONS PER HOUR, RATED HEAT

INPUT IN BRITISH THERMAL UNITS PER HOUR AND

NAME OR SYMBOL OF THE MANUFACTURER.

CONTROL VALVES ARE REQUIRED TO COMPLY

WITH ANSI/UL 125.

CHECK VAL VE SHALL BE INSTALLED NO MORE

THAN 12" FROM THE HOSE FILL CONNECTION.

APPROVALS

CALIF'ORNIA DEPARTMENT OF CORRECTIONS

AND REHABILITATION ACCESS COMPLIANCE

REVIEW

APPROVAL OF THIS PLAN DOES NOT AUTHORIZE OR

APPROVE ANY OMISSION OR DEVIATION FROM THE

APPLICABLE REGULATIONS.

TRACKING NUMBE~~ DATE: 1·'7-UZd REVIEWER: /l YI Af'!e 4-'i I

CALIFORNIA STATE FIRE MARSHAL

APPROVED

FIRE AND PANIC ONLY

APPROVAL Of THIS PLAN DOES NOT AUTHORIZE

OR APPROVE ANY OMISSION OR DEVIATION FROM

THE APPLICABLE REGULATIONS. FINAL APPROVAL

IS SUBJECT TO FIELD INSPECTION. ONE SET Of

APPROVED PLANS SHALL BE AVAILABLE AT THE

PROJEC SITE AT A~<MES.

REVIEWED BY: •

.N1112'.2m z ii:

ii

" el w ,-.

Cl)

>-Cl) a..

...J u z Cl I w

5 a.. w a::

"' " z

~i!

is El ~:i s~

~ il' _., z ::5 Cl) z Cl) a::

w z Cl) w C

"' " z

~i!

is El ~ il' _., 8:0<0 w <( 0, ,-. 0 18 <( a:: 0, ,-. >- <( cncu <( 0 -

- CCI W z<C-' ~w~ u..a.~ ::J8U

c) N ::;

"' " z

~i!

isEj ~2

B~ en

...J u.

en ...J

~ z u I-w J:

I-z >-en

"' " z ~i!

is El ~:i x~ ~ il' -"'

~ I

I N a..

z

C

...J z I uJ ::::E co -ci z u w u w

0 1-.._ __ __..__ ..... _ ;ii

SHEET NUMBER

P2.5.0 t 5-

OF # SHEETS :;-

TBB

California Department of Corrections and Rehabiliation (CDCR) Plans

Bid Number C5612927-D Re-Bid 1 Exhibit A-2

Oval

::I:

Q.

N ..

N - · a, -0 N

a) -,,, 30'·0"

120V/1PH/60HZ

POWER

1··

RAIN CAP

(SEE NOTE #1)

_,.---FLARE STACK

(SEE NOTE #1)

~-------PILOT

(SEE NOTE #1)

r--SHUT-OFFVALVE

(SEE NOTE #1)

LL.~~-- 3" LPG (SEE NOTE #1 )

LJl-----CONTROL PANEL (NEMA 4)

W/ TRANSFORMER, PILOT

MOMENTARY SWITCH.

(SEE NOTE #1)

SHUT-OFF VALVE (TYP)

UNION

~..._INSULATING FLANGE

GUY WIRES TYP. OF 4

WITH ANCHORS, SEE 9 I S2.6.0

FOR DEADMAN FOOTING.

AND CA THOOIC PROTECTION

J:ri'd.lJnt-!2) 3" 150# BLIND FLANGES

(SEE NOTE#1)

I CONCRETE FOUNDATION

11 r3"LPG

~ = = ::J w DIA.MIN.

NOTE:

1, PROVIDED BY FLARE STACK

MANUFACTURER

FLARE STACK DETAIL

SCALE: N.T.S.

NOTE:

120V SEE

ELECTRICAL

DRAWINGS

FURNISH & INSTALL (2) COLOR PLASTIC

ENGRAVED TAGS 2"X2' WITH 3/18" HIGH

LETTERS STATING "LP. VAPOR RETURN &

L.P. LIQUID INLET' AND POSITION TO MATCH

PIPING, FASTEN TAGS PER MFG. RECOMMEN•

DA TIONS FOR OUTDOOR INSTALLATION

SEE SHEET P2.0.0

FOR CONT. OF

REMOTE SHUT-OFF.

TO TANK .

LIQUID

MANIFOLD

18\------1'

MATERIAL UST

TO TANK

LIQUID /

MANIFOLD_,,,..-

0 2" BACK CHECK VALVE

@ 1-114" EMERGENCY SHUTOFF VALVE

@ 2• 400#ANGLEVALVE

01-1/4" 400#ANGLEVALVE

@ 1-1/4" EXCESS FLOW VALVE

@ 1-1/4" HYDROSTATIC RELIEF VALVE

(j) 2" 300# F.S. UNION

© 1-1/4" 300# F.S. UNION

@ 2" NIPPLE SCH. 80

@ 2" NIPPLE SCH. 80

@ 2" NIPPLE SCH. 80

@ 2" NIPPLE SCH. 80

@ 1-1/4" NIPPLE SCH. BO

@ 1-1/4" NIPPLE SCH. BO

@ 1-1/4" NIPPLE SCH. BO

@ 1-1/4" NIPPLE SCH. 80

@ 1-1/4" NIPPLE SCH. BO

@ 2" ELL. 2000# FORGED STEEL

@ 1-1/4" ELL. 2000# FORGED STEEL

@ CAP 3-114" ACME, METAL, W/CHAIN

@ CAP 2-1/4" ACME, NYLON, W/CHAIN

@ 1-1/4" 3000# F.S. COUPLING (WELD TO CHANNEL)

@ ADAPTER 3-114" M. ACME x 2" MNPT

@ADAPTER 2-114" M. ACME x 1-1/4" MNPT

LIQUID INLET

/ VAPORRETURN

I'----@

1~8 l

SEE SHEET S2.6.0

FOR TRUCK UNLOAD

STATION SUPPORT

@ TRUCK UNLOADING STATION BULKHEAD SUBASSEMBLY

BY LPG SYSTEM MANUFACTURER

@ 2" 3000# F.S. FULL COUPLING {WELD TO CHANNEL)

@ 2" TRUCK GROUNDING SOLENOID VALVE.

ELECTRICAL DRAWINGS

TRUCK UNLOADING STATION

SCALE: N.T.S.

RETURN TO

STORAGE TANK

\ INLET

SEE ELECTRICAL DRAWINGS

FOR STARTER LOCATION

~OV/3PH/60HZ

POWER

::t'

~TO PRESSURE

SWITCH

2· / LG

ETURNTO ~ TYP. I

2" LIQUID LINE FROM '·:4 I

/ STORAGE TANK

2" LIQUID

STORAGE TANK 0--1

LIQUID SUPPLY PUl';IP MATERIAL LIST

0 ,,.-..., IB

PUMP W/ORIVE

LPG LIQUID PUMP ELECTRIC MOTOR, CLASS 1, GROUP 0, DIV, 2

STARTER AT MCC-D

2" 400 WOG DUCTILE IRON STRAINER

0-300 LIQUID FILLED PRESSURE GAUGES

2" GLOBE VALVE

114" RELIEF VALVE

LIQUID SUPPLY PUMP

SCALE: N.T.S.

TO VAPORIZER

2" DIFFERENTIAL BYPASS VALVE

2" 400 WOG CHECK VALVE

2• BACK PRESSURE REGULATOR

UNION

FLEX.CONN.

PRESSURE SWITCH

PUMP SKID ON CONCRETE PAD,

SEE 8/S2.6.0 !

, .. .-----·TO TANK DELUGE SYSTEM

TO WET PILOT BRANCHES ~

' DELUGE VALVE WI WET PILOT TRIM-, ••

AND MANUAL RELEASE •• NOTE: CONNECT ALARM DEVICES TO

FIRE ALARM CONTROL PANEL

A ,-

112" NPT

SSSWAGELOK

FlmNG(TYP)

114"SSTUBE

TO ACTUATORS

112" LINE BORE

TOP VIEW

SS SWAGELOK ___ ../

FlmNG

END VIEW

1-112" SS BAR

STOCK (12" LONG)

SSPLUG

1/2" NPT

114" NPT

1/4" SS TUBE

TO ACTUATORS

...--- 1-112" SS BAR

STOCK

---- SSPLUG

PNEUMATIC MANIFOLD - STORAGE TANK

SCALE: N.T.S.

~ SEE BACK BRACE

. DETAILS.

SECTION A-A

MAX WIDTH RECT SIGN= 48" '

K - r_-, ---------1 ·-, ---- I I I I I I I I I •· I I I ' I ' I I I ' ll>C-----1=•=1-----

FRONT VIEW

TTACHSIGNTOPOST .c--~--J""'t-A

WI THBOLTSATTOP,

ENTER AND BOTTOM C

A

- SIGN PANEL------7

END VIEW

4 '

,_f'2.6.0_, " <O

GENERAL NOTES

1. REFER TO SHEET PO.O FOR PLUMBING ABBREVIATIONS, NOTES AND SYMBOLS.

RIGID CALCIUM

SILICATE & SHIELDS.

INSERT AT ALL

SUPPORTS (TYP) ----~

STRUT CHANNEL

SUPPORT, SEE

STRUCT.

SEISMIC

BRACE (TYP) ----.Jl.-jj., NOTES:

I I I I I I

CONCRETE SLAB

AS REQUIRED,

SEESTRUCT.

1iS2.6.0.

PIPE CLAMP

(TYP)

PIPING (TYP)

INSULATION

FINISH GRADE

PLATE SECURED

TO CONCRETE

SLAB AS

REQUIRED

1. SEE SPECIFICATIONS FOR MAXIMUM SUPPORT SPACING

2. PAINT WELDS WI ZINC RICH PAINT BEFORE PAINTING W/ COLOR COAT.

TYPICAL PIPE SUPPORT-GROUND MOUNTED

SCALE: NONE

-::-:-:-::::-r,,-&..\,..,..------~-3/16" STEEL PLATE TUBE CAP (TYP) 3116" -,----,~:::::t=====· 1/2" DIA. $ST BOLT WI HEX NUT AND LOCK WASHER (TYP)

2"X2"X3/16" SQ TS, WELD TD POST AND

EXTEND TO SIDES OF F.E. CABINETW/ TUBE

CAP (BOTH SIDES) r---- FIRE EXTINGUISHER CABINET WI 18 LB MIN.

B:C DRY CHEMICAL EXTINGUISHER

'A'--_J -----EMERGENCY PUSHBUTTON ALARM SWITCH

-,---- , 1-r\.....---- .,,----12" SO. SIGN W/ 1-112" LETTERS "EMERGENCY

:.JV ALARM SWITCH'

I ,,---2"X2'X3/16" SQ. TUBE STEEL (TS) (TYP)

<> <> z z ~z ~is ~o z oBJ ~"' o,,, e,- e,- ~ zai zai iia ~~ !~ c., i~ l:l C

!l il' ~il' a'"' -"'

<:. ~ t i

<> z ~is 1s Bi e,-i~

!!l

"' <> z ~i'i 1s Bl o,-

;g;~ ,le"' i~ a.

<:> z

..J z L,,J

::E

DO -

···--8" OSY VALVE WI

TAMPER SWITCH

4"x4"POST 2" 12" 12" 2R

~~....,..~--! ! 11 I ,,..---(4) 1/2" DIA. TYPE 316 SST ANCHORS.

GRADE

,..,/MANIFOLD DRAINS

/ TOGETHER AND SPILL

OJ ON SPLASH BLOCK.

_ ___..- -- Bfl INCOMING DUCTILE

IRONPIPEW/

RESTRAINING RODS.

DELUGE VALVE DETAIL

SCALE: NONE

PRESSURE REGULATOR

WIPRESSURE GAUGES (TYP)

STAINLESS STEEL

PNEUMATIC TUBING.

(TYP)

SITE GAS DISTRIBUTION ---~

SYSTEM

~1-~(;l--;;1:-'-, SEISMIC BUTTERFLY VALVE L ---;i, I (PNEUMATIC)FAILCLOSED.

)5.-i+r--SOV (TYP)

;--H+- FLEX (TYP) (---,=~..L..;

RETAINER I

J

REMOTE ON-OFF ---L-1

SWITrC"-H'----~ I

..--1--,iw ~' "' .'IC COl,I'-~

RELIEF

l ___ J

,. 7 '

~2.6.0.,.

LPG TANK INTERNAL

PNEUMATIC VA. (N.C.)

TYP. OF 3 ON EACH

TANK, SEE 1/P2.6.1.

VALVES SHALL FAIL

CLOSED.

L..--.---TANKSUPPORT

FOOTING AND PIER

.,,,.- LPG TANK INTERNAL

PNEUMATIC VA. (N.C.)

TYP. OF 3 ON EACH

TANK, SEE1/P2.6.1.

VALVES SHALL FAIL

CLOSED.

L.----TANK SUPPORT

FOOTING AND PIER

SEISMIC

DUMP VA.

NITROGEN CYLINDERS (ONE STAND-BY)

WITH SEISMIC RESTRAINTS IN RACK

MOUNTED ON CONCRETE PAD, SEE

31S2.6,0 AND 5/2.6.0

3-WAY SOLENOID VA.

~- SEISMIC DETECTION

SYSTEM MOUNTED

ON CONCRETE PAD

PNEUMATIC MANIFOLD

(TYP) SEE 3/P2.6.0

'~., - INDICATED NORMAL

POSITION IS WHEN NOT

ENERGIZED.

NOTES:

1. USE STAINLESS STEEL TUBING TO CONNECT

THE TANK ISOLATION VALVES TO THE

NITROGEN CYLINDERS AND EARTHQUAKE

VALVE. PROVIDE AN 18-INCH PIGTAIL FOR

CONNECTIONS THAT REQUIRE MOVEMENT.

PNEUMATIC SAFETY CONTROL

SCALE: N.T.S.

PLAN

1"

3/8"1 HOLE FOR 1/4"1

HEX HEAD BOLT WITH

AAT WASHERS, FIBER

WASHER NUT AND JAM

NUT.

GRADE

00 ..,.

l;> ., 3116"

"' GRADE

;&= l..::==d:=:=,,,,..

3/8" x 3/4" SLOT FOR

1/4"1 HEX HEAD BOLT

WITH AAT WASHERS,

FIBER WASHER NUT

• : ?-~~=>---:::-.12' DIA, (MIN,) CONCRETE FOUNDATION

NOTE: SANO BLAST AND POWDERCOAT ALL

SUPPORT STEEL MEMBERS.

ELEVATION AND JAM NUT. POST EMBEDMENT

BACK BRACE DETAILS

SINGLE POST INSTALLATION-SIGN FIRE EXTINGUISHER CABINET AND ALARM

u a, SCALE: NONE

1/2" SST-EMBED

IN CONCRETE \

2" TUBE STEEL POST

SEE DETAIL 8/P2.6.0

STAINLESS STEEL

CABLE

SCALE: N.T.S.

L----SIGN ON BOTH SIDES OF 2•1NCH SQUARE POST

"EMERGENCY SHUT-OFF VALVE FOR VAPOR

RETURN" • 18" SQ. W/2" LETTERS.

,r:::._....:_:::,._,,,-- 5/8"0 X 4" LG

S.S. EYE BOLT

...--11---- 1 LB LEAD WEIGHT

J::j<-:;;,E:31--- 4" TEE HANDLE

1-t.-==------'I--- CABLE -1/16" S.S.6X7

WELD TO POST

TO VALVE}

ACTUATOR

• .d. . .,, .

6" -~-

L ,•· ... L. ~-~ _ • .'; • ---, ~ .<i ;

I· 10" -I

CROSS SECTION

6"x8"/W1.4xW1.4 W.W.M.

1----__,I I I I Ii STAINLESS STEEL

~ -'\,--~~\,---~PULLEY WITH GUIDE

' 10 "I EMERGENCY SHUTOFF STATION DETAIL

P2.6.0 SCALE: N.T.S.

APPROVALS

CALIFORNIA DEPARTMENT OF CORRECTIONS .

AND REHABILITATION ACCESS COMPLIANCE

REVIEW

APPROVAL OF THIS PLAN DOES NOT AUTHORIZE OR

APPROVE ANY OMISSION OR DEVIATION FROM THE

APPLICABLE REGULATIONS.

TRACKING NUMBER: U!,,t DATE: 1•7•-zn,:, REVIEWER: JidtjJ!f/ 4½e 4~1

CALIFORNIA STATE FIRE MARSHAL

APPROVED·

FIRE AND PANIC ONLY

C ta .., V)

0::

w z

CJ

Cl

N _,.

0 z I-w .., 0::

0..

w I-z <f)

E

"' N

I-..L.-----...a.--1 /i:'

APPROVAL OF THIS PLAN DOES NOT AUTHORIZE S EET N R ~

OR APPROVE ANY OMISSION OR DEVIATION FROM H UMBE ;:;

THE APPLICABLE REGULATIONS. FINAL APPROVAL :;;-

. IS SUBJECT TO FIELD INSPECTION. ONE SET OF p 2 6 0 ]

APPROVED PLANS SHALL BE AVAILABLE AT THE 5-

PROJEC SITE AT ALL MES. • • N

REVIEWED BY:,--1.L"J.+."'-~1-JA_N_0:._2 _2 ___ 02~0 OF /I SHEETS f ---------------------------------------------------------------------------------------------------------------------------------''--------u-----------''---------__, TBB

California Department of Corrections and Rehabiliation (CDCR) Plans

Bid Number C5612927-D Re-Bid 1 Exhibit A-2 matthew.vanatta Rectangle

Rectangle

File details come from the government source that posted it. Updated .