This is an architectural floor plan for the second level of the Idaho State Historical Society Preservation Facility Addition located at 2205 Old Penitentiary Road in Boise, Idaho. The document, prepared by Hutchison Smith Architects and dated July 2025, illustrates a comprehensive renovation and expansion project with a gross square footage of 26,440 square feet on the second level. The plan designates various functional spaces including mechanical storage, main electrical, special collections, existing archive building connections, hallway areas, staging areas, stair access points, and records storage zones. Key project elements include the installation of new hollow metal doors, removal of existing compact mobile shelving systems and exterior EIFS wall finishes, installation of new compacted mobile shelving systems throughout multiple zones, rerouting of roof drains, removal of existing roof drain leaders, and construction of new interior wall partitions using specified metal stud framing and fire barrier walls. The plan incorporates detailed wall type specifications, dimension callouts, control joints, corner guards, and references to structural, mechanical, electrical, plumbing, and civil drawings that are required for complete project implementation.
The document establishes that all contractors must review comprehensive drawing and specification sets across all discipline areas and that the staging area for construction will be determined during pre-bid meetings with the owner. All damaged areas resulting from the work must be restored to original condition at no expense to the owner. The plan was approved by the State of Idaho Department of Project and Lands (DOPL) on September 17, 2025, contingent upon compliance with applied markups and notes, with the approval explicitly noting that it does not constitute approval of any code violations or variances from Idaho's adopted codes, standards, laws, or rules. No pricing, contract term, bid deadline, or incumbent contractor information is contained within this architectural drawing document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A2.00
A2.01
A2.01
1.1 2 3 4 5 6 7 8 107.4
A A
B B
C
D
E
F
1.7
A3.00
A3.00
24'-0" 4'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 11'-6" 18'-6" 25'-4" 1'-8"
1'- 8"
'-0
'-0
'-0
2'-
6"
'-6
'-4
1'-
8"
D.3
MECH. STOR. ELEVATOR
VERTICAL
LIFT
8' X 10'
DN
DN
MAIN ELEC.
1'-8" 2'-0"
OVERALL
238'-8"
SPECIAL
COLLECTIONS
A3.00
A3.00
HALLWAY
A3.01
A3.01
1'- 8"
'-0
'-0
A3.01
A3.01
200E
EXISTING ARCHIVE
BUILDING
'-8
28'-0" 165'-3"
44'-0"
STAGING AREA
A1.03
8A
8B
A3.03
STAIR #1
RECORDS
STORAGE
DN
A3.02
A3.02
F1
F4
F2
F2
F2
E E
A1.05
E1
E1
E1
E1
E1
E
E1
E1
F9
F9
12'-3 5/8" 6'-6" 8'-6 3/4" 3'-4"
5'- 0"
'-2
F12
F12
F12
CH
AS
E 5'-
6"
DUCT CHASE
7'-0"
206B
6A
CR
C R
CR
C R
C R
CR
3'-
4 3 /4"
A4.005
1'- 8"
A
A
A
A
A
SIM. A
A
SIM.
SIM.
F3
F5
A
F6
E
A
A
F7
F7
F8
F12
F12
3'-
A
A
SIM.
SIM.
A
ASIM.
SIM.
F10
F11
F13
'-0
'-4
'-4
'-6
'-1
8'-
6"
32'-10"
'-7
F16
F16
F16
8C
F17F17F17
F17
8'-3"
33'-4" 1'-8"
A6.01
2'- 7"
A
SIM.
A2.01
F16
3'-8"
F16
2'- 3"
4'-0"
F16F16
F18
F18
F18
A2.002
VESTIBULE
COLLECTIONS
STORAGE
STAIR #2
A 6" METAL STUD INTERIOR WALL PARTITION - BASIS OF DESIGN CLARKDIETRICK ProSTUD
33 MIL 600PDS125-33 STUDS AT 16" O.C. AND 5/8" GWB WITH PAINTED AND TEXTURED
FINISH ON BOTH SIDES. FRAMED TO BOTTOM OF STRUCTURE WITH DEFLECTION TRACK
E EXISTING 8" CMU WALL
E1 8" CMU EXTERIOR WALL WITH 4" EIFS FINISH RE: STRUCTURAL DWG FOR REINFORCEMENT
A SAME AS 'A' BUT GYP BOARD ON ONE SIDE ONLY AT CHASE
SIM.
B SAME AS 'A' BUT WITH BATT INSULATION
C SAME AS 'A' BUT WITH BATT INSULATION. GYP BOARD ONE SIDE ONLY
F 6" METAL STUD FIRE BARRIER WALL. METAL STUDS SAME AS WALL TYPE 'A'. CONSTRUCT
WALL PER GA. FILE # WP1072. TEXTURE AND PAINT. FRAME TO BOTTOM OF FLOOR AND
ROOF DECK WITH A DEFLECTION TRACK. SEE PLAN FOR LOCATION OF BATT INSULATION
A.
B.
C.
D.
ALL DIMENSIONS OF NEW WALL ARE TO FACE OF STUD, OR FACE OF CMU
UNLESS NOTED OTHERWISE.
ALL CONTRACTORS ARE REQUIRED TO REVIEW ALL DRAWINGS AND SPECIFICATIONS, SEE
ARCHITECTURAL, CIVIL, LANDSCAPING, STRUCTURAL, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ADDITIONAL PROJECT REQUIREMENTS.
STAGING AREA FOR CONSTRUCTION WILL BE DETERMINED AT THE PRE BID WITH THE
OWNER.
ALL DAMAGED AREAS TO BE RESTORED TO ORIGINAL CONDITION AT NO EXPENSE TO THE
OWNER.
INDICATES ACCESS CONTROL CARD READER. RE: ELECTRICAL DWG
SEE SPECIFICATIONS
CR
A
N.
7t h St
. B
OI
SE
, I
D.
8.
8.
A
R C
H I
T E
C T
S
REF NO.
DPW NO.
DATE
TH
ES
E
DE
SIG
NS
A
ND
D
RA
W
IN
G S A
RE
TH
E
EX
C
LU
SIV
E
PR
O
PE
RT
Y O
F H
UT
C
HI
SO
N
SM
ITH
A
RC
HI
TE
C
TS
, A
ND
A
RE
N O
T T O
B E
US
ED
O R
DU
PL
IC
AT
ED
W
ITH
O
UT
P
ER
M
ISS
IO
N.
C
O
PY
RI
G
HT
4, A
LL
R
IG
HT
S R
ES
ER
VE
D.
PR
O
JE
C
T
PR
O
JE
C
T
AD
D R
ES
S
SHEET NO.
1 2 3 4 5 6 7
B C
D E
PROFESSIONAL OF
REVISION
RECORD STAMP
8/
/2
5:
:1
PM
JULY 2025
23-153
24-620
A1.02
ID
AH
O
ST
AT
E H
IST
OR
IC
AL
SO
CI
ET
Y P
RE
SE
RV
AT
IO
N
FA
CI
LIT
Y A
DD
ITI
ON
O
LD
P
EN
IT
EN
TI
A
R Y
R O
A D
B O
IS
E
ID
A
H O
SE
C
O N
D L
EV
EL
F
LO
O R
P
LA
N
SCALE 1/8" = 1'-0"1 SECOND LEVEL FLOOR PLAN
PLAN
NORTH
KEYNOTES GENERAL NOTES
GROSS SQUARE FOOTAGE = 26,440
F1 NEW HOLLOW METAL DOOR TO BE INSTALLED IN THE EXISTING CMU WALL
F2 EXISTING COMPACT MOBILE SHELVING SYSTEM IN ADJACENT ARCHIVE BUILDING
F3 EXISTING STAIRS
F4 (2) EXISTING SHELVES TO BE REMOVED BY AGENCY ALONG WITH ALL ASSOCIATED ITEMS TO
ALLOW FOR THE INSTALLATION OF A NEW DOOR
F5 REROUTED ROOF DRAIN. RE: ROOF PLAN AND MECHANICAL DWGS
F6 ROOF ACCESS LADDER. SEE DETAIL 5/A6.04
F7 EXISTING EXTERIOR E.I.F.S. WALL FINISH TO BE REMOVED ALONG WITH ALL ASSOCIATED
ITEMS ON ENTIRE FACE OF WALL
F8 SHELVING UNITS. SEE INTERIOR ELEVATIONS 8-9/A4.00
F9 METAL ROOF CANOPY ATTACHED TO EXTERIOR WALL. RE: STRUCTURAL DWG AND 1/A6.05
F10 EXISTING ROOF DRAIN LEADER TO BE REMOVED. SEE SHEET A1.09 ROOF PLAN AND RE:
MECHANICAL DWG FOR REROUTING OF ROOF DRAIN. CAP EXISTING FLOOR AND PATCH AND
PAINT WALL AS REQUIRED
F11 EXISTING OVERFLOW DRAIN LEADER TO BE REMOVED. CAP EXISTING FLOOR. SEE SHEET
A1.09 ROOF PLAN AND RE: MECHANICAL DWG FOR REROUTING OF OVERFLOW DRAIN LEADER.
PATCH WALLS AS REQUIRED AND REPAINT.
F12 NEW COMPACTED MOBILE SHELVING SYSTEM. SEE SPEC
F13 STEEL COLUMN. PAINT. TYP. RE: STRUCTURAL DWG
F16 CORNER GUARD. SEE SPEC
F17 CONTROL JOINT IN GYP BD WALL, NOT TO EXCEED 30'-0" O.C. SEE DETAIL 2/A6.06
F18 INSERT RAILS FOR COMPACT MOBILE SHELVING. SEE STRUCTURAL
WALL TYPES
LEGEND
Approved
State of Idaho
DOPL
PA#:
Date:
1682178 9/17/2025
These plans are approved contingent on the compliance with the mark-ups and notes applied.
This approval shall not be construed to be an approval of any violation of, or variance from, Idaho's adopted codes, standards, laws or rules applicable to this project.
File details come from the government source that posted it. Updated .