Exhibit 8 - ISHS A1.02 SECOND LEVEL FLOOR PLAN.pdf

PDF 789 KB Posted

Attached to
ISHS Artifact Collections Packing and Moving
Solicitation number
1126
Issued by
Ada County, Idaho

About this file

This is an architectural floor plan for the second level of the Idaho State Historical Society Preservation Facility Addition located at 2205 Old Penitentiary Road in Boise, Idaho. The document, prepared by Hutchison Smith Architects and dated July 2025, illustrates a comprehensive renovation and expansion project with a gross square footage of 26,440 square feet on the second level. The plan designates various functional spaces including mechanical storage, main electrical, special collections, existing archive building connections, hallway areas, staging areas, stair access points, and records storage zones. Key project elements include the installation of new hollow metal doors, removal of existing compact mobile shelving systems and exterior EIFS wall finishes, installation of new compacted mobile shelving systems throughout multiple zones, rerouting of roof drains, removal of existing roof drain leaders, and construction of new interior wall partitions using specified metal stud framing and fire barrier walls. The plan incorporates detailed wall type specifications, dimension callouts, control joints, corner guards, and references to structural, mechanical, electrical, plumbing, and civil drawings that are required for complete project implementation.

The document establishes that all contractors must review comprehensive drawing and specification sets across all discipline areas and that the staging area for construction will be determined during pre-bid meetings with the owner. All damaged areas resulting from the work must be restored to original condition at no expense to the owner. The plan was approved by the State of Idaho Department of Project and Lands (DOPL) on September 17, 2025, contingent upon compliance with applied markups and notes, with the approval explicitly noting that it does not constitute approval of any code violations or variances from Idaho's adopted codes, standards, laws, or rules. No pricing, contract term, bid deadline, or incumbent contractor information is contained within this architectural drawing document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A2.00

A2.01

A2.01

1.1 2 3 4 5 6 7 8 107.4

A A

B B

C

D

E

F

1.7

A3.00

A3.00

24'-0" 4'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 11'-6" 18'-6" 25'-4" 1'-8"

1'- 8"

'-0

'-0

'-0

2'-

6"

'-6

'-4

1'-

8"

D.3

MECH. STOR. ELEVATOR

VERTICAL

LIFT

8' X 10'

DN

DN

MAIN ELEC.

1'-8" 2'-0"

OVERALL

238'-8"

SPECIAL

COLLECTIONS

A3.00

A3.00

HALLWAY

A3.01

A3.01

1'- 8"

'-0

'-0

A3.01

A3.01

200E

EXISTING ARCHIVE

BUILDING

'-8

28'-0" 165'-3"

44'-0"

STAGING AREA

A1.03

8A

8B

A3.03

STAIR #1

RECORDS

STORAGE

DN

A3.02

A3.02

F1

F4

F2

F2

F2

E E

A1.05

E1

E1

E1

E1

E1

E

E1

E1

F9

F9

12'-3 5/8" 6'-6" 8'-6 3/4" 3'-4"

5'- 0"

'-2

F12

F12

F12

CH

AS

E 5'-

6"

DUCT CHASE

7'-0"

206B

6A

CR

C R

CR

C R

C R

CR

3'-

4 3 /4"

A4.005

1'- 8"

A

A

A

A

A

SIM. A

A

SIM.

SIM.

F3

F5

A

F6

E

A

A

F7

F7

F8

F12

F12

3'-

A

A

SIM.

SIM.

A

ASIM.

SIM.

F10

F11

F13

'-0

'-4

'-4

'-6

'-1

8'-

6"

32'-10"

'-7

F16

F16

F16

8C

F17F17F17

F17

8'-3"

33'-4" 1'-8"

A6.01

2'- 7"

A

SIM.

A2.01

F16

3'-8"

F16

2'- 3"

4'-0"

F16F16

F18

F18

F18

A2.002

VESTIBULE

COLLECTIONS

STORAGE

STAIR #2

A 6" METAL STUD INTERIOR WALL PARTITION - BASIS OF DESIGN CLARKDIETRICK ProSTUD

33 MIL 600PDS125-33 STUDS AT 16" O.C. AND 5/8" GWB WITH PAINTED AND TEXTURED

FINISH ON BOTH SIDES. FRAMED TO BOTTOM OF STRUCTURE WITH DEFLECTION TRACK

E EXISTING 8" CMU WALL

E1 8" CMU EXTERIOR WALL WITH 4" EIFS FINISH RE: STRUCTURAL DWG FOR REINFORCEMENT

A SAME AS 'A' BUT GYP BOARD ON ONE SIDE ONLY AT CHASE

SIM.

B SAME AS 'A' BUT WITH BATT INSULATION

C SAME AS 'A' BUT WITH BATT INSULATION. GYP BOARD ONE SIDE ONLY

F 6" METAL STUD FIRE BARRIER WALL. METAL STUDS SAME AS WALL TYPE 'A'. CONSTRUCT

WALL PER GA. FILE # WP1072. TEXTURE AND PAINT. FRAME TO BOTTOM OF FLOOR AND

ROOF DECK WITH A DEFLECTION TRACK. SEE PLAN FOR LOCATION OF BATT INSULATION

A.

B.

C.

D.

ALL DIMENSIONS OF NEW WALL ARE TO FACE OF STUD, OR FACE OF CMU

UNLESS NOTED OTHERWISE.

ALL CONTRACTORS ARE REQUIRED TO REVIEW ALL DRAWINGS AND SPECIFICATIONS, SEE

ARCHITECTURAL, CIVIL, LANDSCAPING, STRUCTURAL, PLUMBING, MECHANICAL, AND

ELECTRICAL DRAWINGS FOR ADDITIONAL PROJECT REQUIREMENTS.

STAGING AREA FOR CONSTRUCTION WILL BE DETERMINED AT THE PRE BID WITH THE

OWNER.

ALL DAMAGED AREAS TO BE RESTORED TO ORIGINAL CONDITION AT NO EXPENSE TO THE

OWNER.

INDICATES ACCESS CONTROL CARD READER. RE: ELECTRICAL DWG

SEE SPECIFICATIONS

CR

A

N.

7t h St

. B

OI

SE

, I

D.

8.

8.

A

R C

H I

T E

C T

S

REF NO.

DPW NO.

DATE

TH

ES

E

DE

SIG

NS

A

ND

D

RA

W

IN

G S A

RE

TH

E

EX

C

LU

SIV

E

PR

O

PE

RT

Y O

F H

UT

C

HI

SO

N

SM

ITH

A

RC

HI

TE

C

TS

, A

ND

A

RE

N O

T T O

B E

US

ED

O R

DU

PL

IC

AT

ED

W

ITH

O

UT

P

ER

M

ISS

IO

N.

C

O

PY

RI

G

HT

4, A

LL

R

IG

HT

S R

ES

ER

VE

D.

PR

O

JE

C

T

PR

O

JE

C

T

AD

D R

ES

S

SHEET NO.

1 2 3 4 5 6 7

B C

D E

PROFESSIONAL OF

REVISION

RECORD STAMP

8/

/2

5:

:1

PM

JULY 2025

23-153

24-620

A1.02

ID

AH

O

ST

AT

E H

IST

OR

IC

AL

SO

CI

ET

Y P

RE

SE

RV

AT

IO

N

FA

CI

LIT

Y A

DD

ITI

ON

O

LD

P

EN

IT

EN

TI

A

R Y

R O

A D

B O

IS

E

ID

A

H O

SE

C

O N

D L

EV

EL

F

LO

O R

P

LA

N

SCALE 1/8" = 1'-0"1 SECOND LEVEL FLOOR PLAN

PLAN

NORTH

KEYNOTES GENERAL NOTES

GROSS SQUARE FOOTAGE = 26,440

F1 NEW HOLLOW METAL DOOR TO BE INSTALLED IN THE EXISTING CMU WALL

F2 EXISTING COMPACT MOBILE SHELVING SYSTEM IN ADJACENT ARCHIVE BUILDING

F3 EXISTING STAIRS

F4 (2) EXISTING SHELVES TO BE REMOVED BY AGENCY ALONG WITH ALL ASSOCIATED ITEMS TO

ALLOW FOR THE INSTALLATION OF A NEW DOOR

F5 REROUTED ROOF DRAIN. RE: ROOF PLAN AND MECHANICAL DWGS

F6 ROOF ACCESS LADDER. SEE DETAIL 5/A6.04

F7 EXISTING EXTERIOR E.I.F.S. WALL FINISH TO BE REMOVED ALONG WITH ALL ASSOCIATED

ITEMS ON ENTIRE FACE OF WALL

F8 SHELVING UNITS. SEE INTERIOR ELEVATIONS 8-9/A4.00

F9 METAL ROOF CANOPY ATTACHED TO EXTERIOR WALL. RE: STRUCTURAL DWG AND 1/A6.05

F10 EXISTING ROOF DRAIN LEADER TO BE REMOVED. SEE SHEET A1.09 ROOF PLAN AND RE:

MECHANICAL DWG FOR REROUTING OF ROOF DRAIN. CAP EXISTING FLOOR AND PATCH AND

PAINT WALL AS REQUIRED

F11 EXISTING OVERFLOW DRAIN LEADER TO BE REMOVED. CAP EXISTING FLOOR. SEE SHEET

A1.09 ROOF PLAN AND RE: MECHANICAL DWG FOR REROUTING OF OVERFLOW DRAIN LEADER.

PATCH WALLS AS REQUIRED AND REPAINT.

F12 NEW COMPACTED MOBILE SHELVING SYSTEM. SEE SPEC

F13 STEEL COLUMN. PAINT. TYP. RE: STRUCTURAL DWG

F16 CORNER GUARD. SEE SPEC

F17 CONTROL JOINT IN GYP BD WALL, NOT TO EXCEED 30'-0" O.C. SEE DETAIL 2/A6.06

F18 INSERT RAILS FOR COMPACT MOBILE SHELVING. SEE STRUCTURAL

WALL TYPES

LEGEND

Approved

State of Idaho

DOPL

PA#:

Date:

1682178 9/17/2025

These plans are approved contingent on the compliance with the mark-ups and notes applied.

This approval shall not be construed to be an approval of any violation of, or variance from, Idaho's adopted codes, standards, laws or rules applicable to this project.

File details come from the government source that posted it. Updated .