This is a standard drawing specification document from the Oregon Department of Transportation establishing construction standards for barbed and woven wire fences (RD810). The document provides detailed technical specifications for fence construction, including two primary fence types (Type 1 and Type 1-5W for barbed wire, and Type 2 for woven wire fabric) with variations based on post material (wood or metal) and site conditions. The specifications include comprehensive dimensional requirements, material standards, and installation details for line posts, end posts, gate posts, and bracing systems. Post spacing ranges from 16'-6" to 2'-2" depending on fence type and radius of curvature, with wire gauges specified as either barbed wire (4 to 5 strands minimum) or rectangular woven fabric. All materials must comply with ASTM standards, AASHTO specifications, and current Oregon Standard Specifications. The drawing was revised on January 13, 2020, with an effective date of June 1, 2026 through November 30, 2026.

The specifications require wooden stays in areas experiencing heavy snowfall or snow drifts exceeding 36 inches and mandate commercial grade concrete for all footings with minimum 18-inch depth. Metal posts must conform to ASTM A-702 standards with specified weight per foot, diameter tolerances, and tapered dimensions. Bracing requirements include both Unit A and Unit B components for certain fence lengths and configurations, with Unit A required at all gate posts. The document references companion standard drawings (RD820 for fence gates) and requires consultation with a registered professional engineer for design applications. No pricing, bid amounts, set-asides, or contract term information is included in this technical specification document.

View the file

Other files

File Type Posted
Exhibit 5 ESB 2026 I-5 NB Exit 86 Fence_Specs.pdf PDF
00017035 ESB_RFCQ.docx DOCX document
00017035 ESB_Sample_Contract.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RD810

FENCES

BARBED AND WOVEN WIRE

R D

.d g n

13-JAN-2020N/A

J U

L xxxxxxxxxxxx x x x x x xxxxx x x x x x xxxxxx x x xxx x xx x xx x x x x x x x x x x x x xxxxx x x x x x x x x x x x xxxxxxx x x x x x x x xxx xx x x x xx x xxx xxxxx x x x x x x x x x x x x x xxx x x x xx x x x x x x xx xx x x x x x x xx x x x x x x xx

B

C

WIRES

NO. OF

10"

14"

10"

12"

Type 1-5W

Type 1

1 1

SQUARE

SHAPE

a a a a b b

FENCE C SPACING

stake

1"x2"x12"

Lever metal posts)

(See wood or

Gate post from end of locking bar.

post and approx. 5" welded or bolted to gate

" short link coil chain4 line post material)

4'-4" (Metal

End bar Length

3" normal

Gate post

6 gauge thkn. wire loop wood line post material)

Length 4'-4" (Metal or

End bar

6 gauge thkn. wire loop

3" normal m in m in

Ground linewire loop

6 gauge thkn.

line post material) approx.2'-2" (Metal

Locking bar

Fence stays gauge wire2

6 gauge thkn. wire loop

30" (Type 2)

(33' max. for type 2 fence material)

Width as indicated on plan

5'-6" max. 5'-6" max. 5'-6" max.

3 For wooden stays, see Type 1 fence details.

2 For details not shown see fence type.

1 Match adjointing fence type.

Fence material Fence material Fence materialNOTES:

thkn. wire gauge2

Fence stays

4 or 5 barbed wires

2" min.

Ground line

Post

NOTE:

1 5'-6" 5'-6" ta b le b e lo w

F o r s p a c in g s e e for woven wire fabric.

Horizontal wires to be stapled are: single wires and a minimum of 4 wires on the ground.

Hemlock or Western Pine, spaced as shown for wire stays and to rest firmly

Stays to be 2"x2"x52" min. length, sound, untreated Douglas Fir, Western

Wooden Stays to be used in areas of heavy snowfall or snow drifts over 36".

wire fabric

Rectangular woven

832-6-12

Design number details see Type 1 fence

For wooden stays, NOTE:

Recommendation R9-47.

Simplified Practice

U.S. Dept. of Commerce

Post2

"Barbed wire

Ground line

Unit A required at gate post.

fence line at intersection with new fence line.

Either Unit A or Units A & B are required in existing

Over 330

20-330

20 or Less

Types

1-5W &

1, A & B

A

None

FENCE

R

(ft) REQUIRED

UNITS

TABLE 1 (For wood posts)

TABLE 2

TABLE 3

3" to 4"

All Types 660' 16'-6" 7'-6" 6'-6" 4'-4" 3'-2" 2'-2" 7'-8" 9"-22"

ASTM A-7021.33 lb or U-bar

Tee Channel 3"x3"3"Line Post

Brace Rail

Brace or

"2 to 5

"2

Other Post 4" to 7" 5"

4"

5"x5"

4"x4" Tubular

Angle

Tubular

Angle

3.19 lb b

4.1 lb "4

"x2

"x22

" O.D.8

"4

2"x2"x

" +/- O.D.2 min.-max. min. avg.

FENCE

max.

R P min.

L min.

L H min.

D min.

D min.

B min.-max.

X

MEMBER

SMALL END (in)

DIAMETER OF

ROUND

(in) nominal

SIZE

nominal

PER (ft)

WEIGHT

nominal

SIZE

WOOD METAL

Max. taper 1":48".

in each dimension.

Max. allowable size 1" additional

In accordance with ASTM A 702.

In accordance with AASHTO M 181.

corner post unit

End, gate or m in

12"

Brace min.

Concrete footing min.

nom. wt. 0.67 lbs

Anchor plate footing

Concrete

Brace

Line post

Intermediate end post line

Ground

Brace min.

18" min.

min.

2"

D H

L

X

B

P

R

B

X

H

L

D

12"

H D

L

22" round

20" sq. or

22" round

18" sq. or

22" round

20" sq. or

22" round

18" sq. or

2"

2"

8'-3"8'-3"

Wood brace rail steel dowel

"dia. x4"8

Wood post

Brace post thkn. wire

4 stands of 9 gauge

Brace guys Brace post

Brace rail Intermediate end post

3. For cross sectional dimensions of members see Table 3.

2. Line post spacing same as dimension P.

1. For dimensions indicated by letter see Table 2.

NOTES:

1"x2"x12" stake

Lever

8'-3" 8'-3"

R

P

H

L

D

D

L

H

Brace post

D

L

H

UNIT A UNIT B

For units required see Table 1 corner post unit(s)

End, gate or

Brace rail wire

9 gauge thkn.

4 strands of

Brace guy guy at gate posts

Additional brace line

Ground

Line post

21 21 21

GATEWAY

TYPES 1 , & 1-5W

BRACE RAIL CONNECTIONMETAL POSTS

WOOD POSTS

TYPE 2

TYPE 2TYPE 1-5WTYPE 1

7. Add fence grounding as required.

6. See project plans for details not shown.

5. See Std. Dwg. RD820 for fence gates.

4. All concrete shall be commercial grade concrete.

3. For shapes, weights and dimensions of members see Table 3.

2. Line post spacing same as dimension P.

1. For dimensions indicated by letter see Table 2.

GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:

TABLE OF DIMENSIONS

the current Oregon Standard Specifications.

All materials shall be in accordance with

DATE REVISION DESCRIPTION

OREGON STANDARD DRAWINGS

DATE

SDR

BOOK NO.

CALC.

Effective Date: June 1, 2026 - November 30, 2026

Professional Engineer.

first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with

Standard Drawing, while

The selection and use of this

File details come from the government source that posted it. Updated .