Exhibit 6 Plans~3.pdf

PDF 5 MB Posted

Attached to
US97 WIM SENSOR AND PAVEMENT REPLACEMENT PROJECT (Klamath Falls)
Solicitation number
S-73000-00018466
Issued by
Jackson County, Oregon

About this file

Exhibit 6 Plans Summary

This document appears to be a planning exhibit or architectural drawing set related to a construction or facility project. The file contains detailed plans and specifications that serve as supporting documentation for the contract opportunity. The plans likely illustrate the scope of work, project specifications, site layouts, or technical requirements that bidders must review and understand to prepare accurate proposals. These exhibits are typically provided to establish clear expectations regarding the physical parameters, design standards, and construction or service delivery specifications that will govern the project execution.

The exhibit functions as a critical reference document for all prospective bidders, ensuring that all parties have access to identical baseline information regarding project requirements and site conditions. Bidders are expected to review these plans thoroughly before submitting responses, as the plans establish binding specifications and performance standards. Any discrepancies or questions regarding the plans should be addressed through the formal bidders' conference or written inquiry process established by the contracting agency to ensure uniform understanding and fair competition among all respondents.

View the file

Other files

File Type Posted
00018455 ITB.docx DOCX document
00018455 Sample Contract.docx DOCX document
00018455 ATT A Form A-2 Bid Pricing Form~2.xlsx XLSX spreadsheet
Exhibit 5 Specifications and Special Provisions).pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THE DALLES – CALIFORNIA HIGHWAY

KLAMATH COUNTY

SB LOCATION

NB LOCATION

Jeff Shambaugh Date: 2026.11.02 08:48:37 -08'00'

Median Travel Lane Travel Lane Var’ Right Shoulder Left Shoulder

3” cold plane pavement removal - CPPR

ACP Base Course Level 3, ½” PG 64-28

Nom. thkn – 8”

- 2” 3rd lift

- 3” 2nd lift

- 3” 1st lift

ACP Wearing Course Level 3, ½” PG 64-28 thkn – 3”

Typical Paving – US97

• Not to Scale

• For more detail on saw cut and removal area see sheet BB02 & BB03

Saw Cut width See BB02

CPPR See BB02

Saw Cut

Saw Cut

12” Aggregate

5” cold plane pavement removal - CPPR

Sheet BB01

Extg PCC Pavement.

CPPR width See BB02

The relative location varies NB vs SB. The removal of PCC will include the width of existing PCC and nominal sections of existing AC pavement. For more details see BB02

SB PCC relative location

NB PCC relative location

Existing PCC is anticipated to be between 9-11 inches thick.

NB PCC

30ft

15ft

As located (ft)

SB

NB

5”

CPPR

5”

CPPR NB

Extg PCC 30ft

5” CPPR

3” CPPR Pavement Removal

Area

(PRA)

US97 NB Location MP 272.23

SB PCC

30 ft

NB

SB

US97 SB Location MP 270.89

5”

CPPR

5”

CPPR

30 ft Extg PCC

15ft

Sheet BB02 For more detail see sheet BB01

For more detail see sheet BB01

Median

Median

In affected area, remove and replace existing rumble strip in-kind.

At NB location remove existing PCC, bases, and misc.

structures to subgrade from median to min. of lane 14 ft wide or 2ft outside the edge of PCC over distance of PCC

At SB location remove existing PCC, bases, and misc.

structures to subgrade from median lane line to outside edge of the PCC pavement.

(min. 6” removal of extg. AC along median edge)

3” CPPR Pavement Removal

Area

(PRA)

5” CPPR

At NB location 3” CPPR 1ft to into the median and 3ft into right shoulder, over length of pavement removal, and 30 ft beyond both ends of the area of removal.

At SB location 5” CPPR that matches the width of removal and 15ft beyond each end of removal.

Cold Plane Pavement Removal - CPPR

Lengths and widths shown are approximate, final length, width, and areas will be field located by

ODOT staff.

At NB location 5” CPPR that matches the width of removal and 15ft beyond each end of removal.

As located (ft)

At NB location 3” CPPR 3ft to into the median and 1ft into right shoulder, over length of pavement removal, and 30 ft beyond both ends of the area of removal.

15ft

15ft

Not to scale

Not to scale

Misc. PCC.

Str.

At NB & SB locations remove existing misc. structures in the

AC shoulders. Where these structures are outside the saw cut perimeter of the PRA, back fill with 6” AC (2 equal lifts) and 17” of aggregate base.

Misc.

other. Str.

Subgrade

Subgrade geotextile

18" SUBGRADE STABILIZATION

1. As directed, the 18" subgrade stabilization may be omitted if subgrade is firm and unyielding.

2. Excavate to a depth of 18" below subgrade.

3. Replace with 18" of stone embankment subbase prior to placement of aggregate base.

For surfacing details see sht. 8801

Subgrade

Subgrade geotextile

Stone embankment subbase Nam. comp. thkn. - 18"

BB03

hwye97v Rectangle

2026.10.28 13:41:31 -07'00'

2026.10.28 13:31:22

2026.10.27 15:27:25

2026.10.27 15:27:48

2026.10.27 15:28:05

2026.10.27 15:28:24

2026.10.27 15:28:41 the current Oregon Standard Specifications.

All materials shall be in accordance with

DATE REVISION DESCRIPTION

OREGON STANDARD DRAWINGS

DATE

SDR

BOOK NO.

CALC.

Effective Date: December 1, 2026 - May 31, 2027

Professional Engineer.

first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with

Standard Drawing, while

The selection and use of this

TM700

CONDUIT TRENCHING

GENERAL

T M

.d g n

01-2025

10-JAN-2025N/A

J A

N

2" Bedding

2" Cover

30"

24"

18"

18"

Thickness, Whichever Is Greater

6" Min. Or Match Existing Surface

Conduit

CLSM

Conduit

Non-Metallic

Metallic

Roadway & Shoulders Other AreasType Of Conduit

Or Upper Limit Of Excavation

Subgrade, Surrounding Ground, Top Of Trench, Bottom Of

When Using Rigid Metallic Conduit)

Sand Blanket (May Be Omitted

Top Of Existing Surface

CONDUIT OPEN TRENCH EXCAVATION & BACKFILL

under sidewalk, landscaped areas, etc.)

UNSURFACED AREAS (new roadway prior to paving, shoulders, 6" (Nominal)

Top Of Finished Surface

For The Entire Length Of The Conduit Run

Center Underground Marking Tape Over Conduit

MINIMUM COVER FROM FINISHED SURFACE

(Use Permit Depth If Greater Than These)

Minimum Cover From Top of Finished Surface

Minimum Cover Table)

Minimum Cover (See

Minimum Cover Table)

Minimum Cover (See

Optic Hand Hole As Per TM702, The Minimum Cover Depth Is 24 Inches.

2. For Non-Metallic Conduit Under Roadway & Shoulders Installed Horizontally Into Fiber

More Information.

To Accommodate The Minimum Radius ("R") Of The Conduit Elbow. See TM701 For

1. Additional Cover Depth May Be Necessary Near Foundations And Junction Boxes

Notes:

Than 6" According To 00405.46(C)(2).

Material. Compact Material In Layers Not Greater

Selected Granular Or Selected General (Native)

Along The Boundaries Of The Area To Be Removed

With An Approved Pavement Cutting Saw 2" Minimum Depth

When Excavating, Cut Sharp And Well Defined Pavement Edges

Finish To A Smooth Riding Surface.

00745, 00755, And 00756, As Applicable.

Compact Material According To 00744, Match Existing Surface Material: PCC Or ACP

6. Furnish Backfill Materials According To 00960.10

5. Do Not Backfill Trenches Until Inspected By The Engineer

4. Hold Trench Width To A Practical Minimum

Place All Conduit Before Paving Or Landscaping.

3. Excavate According To 00960.40. In Areas To Be Paved Or Landscaped, Changed To Avoid Obstructions.

2. Conduit Runs Shown On Plans Are For Bidding Purposes Only. Locations May Be

1. Install Conduit By Open Trench Method, Horizontal Directional Drilling, Or As Shown

General Notes:

(See Note 2)

CONDUIT OPEN TRENCH EXCAVATION & BACKFILL

EXISTING PAVED AREAS

NEW DRAWING (CONTENT FROM RETIRED TM471)

DATE REVISION DESCRIPTION

OREGON STANDARD DRAWINGS

DATE

SDR

BOOK NO.

CALC.

Effective Date: December 1, 2026 - May 31, 2027

Professional Engineer.

first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with

Standard Drawing, while

The selection and use of this

TM701

T M

.d g n

NEW DRAWING (CONTENT FROM RETIRED TM470 & TM471)01-2025

13-JAN-2026N/A

J A

N

Future Use (No Wires/Cables In Conduit). Leave 6 Feet Of Slack Pull Line.

6. Install Polyethylene Pull Line In All Conduits Noted On The Plans For

Poles, Cabinets Unless Otherwise Shown.

5. Leave A Minimum Of 2 Feet Slack In Each Wire And Cable In Junction Boxes,

4. Tape The Ends Of Unused Conductors With Insulated Vinyl Plastic Tape.

Common Wire Nut Unless Otherwise Shown.

And Install A Wire Nut. Do Not Join Multiple Locate Wires Under A All Conduits As A Locate Wire. Leave Slack As Shown Or Directed

3. Install No. 16 AWG TFFN Orange Base With Blue Tracertone Wire In

Unless Otherwise Shown.

Handheld Labeler (Brady M210 Label Maker With Vinyl B-595 Tape)

2. Label Wires And Cables With Permanent Tags As Shown Or Directed. Use

To Specification Section 00990 Bid Items.

1. See TM470 For Additional Wire/Cable Installation Requirements That Apply

Wire & Cable Installation General Notes:

LUBRICANT

Wires And Cables In Conduit Use Electrical Lubricants When Inserting

Pulls Are Made With Poles Or Controller Cabinets In Place

* Use A Pulley Device To Achieve A Straight Line If

Terminating End Points For Pulling Only Binding Material) Allowed Only At The Wire (Tapes, Straps, Ties, Or Other Temporarily Bundling Cables Or

The Conduit Opening* Pull In A Straight Line With

Cables By Hand Only Pull All Wires And

WIRE & CABLE INSTALLATION IN CONDUITS

CONDUIT INSTALLATION IN JUNCTION BOXES

CONDUIT INSTALLATIONS IN FOUNDATIONS

Junction Box

2" Min. To 3" Max.

Fiberglass Conduit Elbow

(Direction Of Conduit Run)

Plumb)

(Install

PVC Riser

Of The Conduit Run

Near The End Wall From The Direction

Enter Through The Bottom Of The Box

Conduit (Size As Shown On Plans).

2" Min. To 3" Max.

Fiberglass Riser (Install Plumb)

Foundation

Concrete

Fiberglass Elbow

Elbow

Fiberglass

Shown On Plans)

Conduit (Size As

Shown On Plans)

Conduit (Size As

Coupling

Coupling

Top Of Foundation

JB3 34"

JB2 18"

JB1 12"

From End Wall

2" To 3" Typ.

Diameters

Of Conduit

Max. Sum

Box Type

Junction

If Max. Sum Of Conduit Diameters In Junction Box Is Not Exceeded.

2. Larger Conduit Than Specified May Be Used At The Option And Cost Of The Contractor

Between Any Pole, Junction Box, Or Cabinet.

1. Install Non-Metallic Conduit Unless Otherwise Shown. Conduit Runs Shall Be Continuous

Conduit Installation General Notes:

Beyond Foundation

Conduit 10" To 12"

Extend Fiberglass

R

R

Diameter

Conduit

Coupling

Manufacturer's Recommendation.

Weld To Connect Conduit As Per

Full Circumference. Use Solvent

Conduit Ends Fit Together For Their

Make Cuts Square And True So

Non-Metallic Conduit

CONDUIT ENDS AND BUSHINGS

CONDUIT ELBOWS

CONDUIT COUPLINGS

3" Min.

Plug

Conduit

Foam

Wiring (Or Pull Line) Is Installed

Install Foam Conduit Plug After For Future Use Only)

(Or Pull Line in Conduit

Cables/Wires

R (min.)

Fiberglass Riser (In Foundations)

PVC Riser (In Junction Boxes) Or

1/2" To 1" Above Conduit Bushing

Diameter

Than Riser

" Larger1/2

Before Installing Wire

End Bell Conduit Bushings

Install Push-On PVC

3" 18"

2 1/2" 15"

2" 12"

1 1/2" 10"

Size Conduit For The Entire Length, Outlet To Outlet.

1. Slip Joints, Running Threads Or Reducing Couplings Not Allowed. Use The Same

Notes:

2. Temporarily Plug Or Cap Conduit Ends At All Times To Keep Debris Out

1. Ream Conduit Ends To Remove Rough Edges And Burrs

Notes:

Manipulation, Or Cutting In The Field)

(No Crimping, Flattening, Field

Standard Factory Fiberglass Bend

INSTALLATION

CONDUIT & WIRE/CABLE

GENERAL

01-2026 DELETED APPLICABILITY LANGUAGE IN CONDUIT IN FOUNDATIONS DETAIL

DATE REVISION DESCRIPTION

OREGON STANDARD DRAWINGS

DATE

SDR

BOOK NO.

CALC.

Effective Date: December 1, 2026 - May 31, 2027

Professional Engineer.

first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with

Standard Drawing, while

The selection and use of this

TM702

T M

.d g n

NEW DRAWING (CONTENT FROM RETIRED TM472)01-2025

11-JUL-2025N/A

J U

L

INSTALLATION

JUNCTION BOX/HAND HOLE

GENERAL

SIGNALS

S

S

A

2"

S

SECTION A-ASECTION B-B

TANDEM JB/3A JUNCTION BOX DETAILS

B

B

DIMENSION TABLE

D

LW

SI

GNALS

COVER DETAILS

JUNCTION BOX

To Secure Cover Or Hex Head Bolts Steel / Brass "L" Bolts Use Two Stainless

S

(See Std. Dwg. TM570 And TM571)

Type 1, Type 1U, Or Type 2 Delineator

PCC Apron

JUNCTION BOX INSTALLATION IN PCC SIDEWALK

Hand Hole

Junction Box Or

HAND HOLE IN UNSURFACED AREA

DELINEATION OF JUNCTION BOX &

S

IG

N A

LS

S

S

IN UNSURFACED AREA

JUNCTION BOX INSTALLATION

Chamfer (Typ.)

45 Degree

PCC Apron

2"

"12"

31/2"

"1/23

PCC Apron

12" Junction Box Cover

(See Note 4)

Crushed Rock

3/4" - 0"

12" Min.

3 1/2"

EdgeOfSidewalkOrEdgeOfRamp

2'-0"Min.OfSoftscapeFrom

SoftscapeAsShown

Sidewalk

PCC Junction Box Apron

Paved Shoulders, Or Other Areas Exposed To Traffic.)

Behind Guardrail, Etc. Do Not Install In Travel Lanes, Located In Incidental Travel Areas; Gravel Shoulders, (This Detail Only Applicable for Junction Boxes

Sidewalk

Back Of Sidewalk

Mi n.

Mi n.

TravelLane

Face Of Curb

Dirt Or Soil

Junction Box Cover

(See Note 4)

3/4" - 0" Crushed Rock

Compacted Backfill OrSidewalk

2"

(See Note 4)

Crushed Rock

3/4" - 0"

12" Min.

Flat Areas Of Sidewalks. Do Not Install In Slopes Of Ramps Or Driveways) (This Detail Only Applicable for Junction Boxes Located In

Sidewalk Surface PCC Apron Or

Cables In The Other JB/3 Detector And Interconnect Wiring In One JB/3 And Install Signal And Illumination The Controller Cabinet In The Tandem JB/3 Nearest

4"

Sufficient Coverage To Produce A Firm Unyielding Surface. Do Not Install Conductors Until Surface Has Been Constructed.

4. Use Materials According To 00640.10 and 00640.16. Use Compaction Equipment Suitable For Area And Compact Each Six Inch Layer With

3. More Junction Boxes And Hand Holes Than Specified May Be Installed To Facilitate The Work At The Option And Cost Of The Contractor

And No More Than 1000 Feet Apart For Hand Holes.

2. Install Junction Boxes And Hand Holes At The Approximate Locations Shown, Or If Not Shown, No More Than 300 Feet Apart For Junction Boxes

Or Shoulder, Leave The Top Of The Hand Hole 1/2" Below The Pavement Surface.

1. Install Top of Junction Box And Hand Hole Flush With The Sidewalk, Surrounding Grade, Or Top Of Curb. For Hand Holes Installed In The Roadway

GENERAL NOTES:

Type* L W D

12"

12"

12"

17"

12"

10"

30"

22"

17"

JB3

JB2

JB1

HH-3

HH-2

HH-1

30"

30"

24"

48"

48"

30"

36"

24"

24"

Type As Shown On Plans

*Junction Box Or Handhole

Or Max. 3/8" Lift Hole With Recessed Lifting Eye Junction Box Cover

Lift Eye

Behind Box

3'- 0" Max.

Reading, "JCT. BOX"

3" B Font Text

White Target With Black

Systems (Letter Height 1" Min.)

Or "ELECTRICAL" For ITS/Misc. Electrical "ILLUMINATION" For Illumination, "SIGNALS" For Traffic Signal, Cover To Be Marked

TOP VIEW

FIBER OPTIC CABLE HAND HOLE INSTALLATION

For Nut, Typ.

Recess In Cover Secure Cover.

(Hex Head) To Steel Bolts 304 Stainless Use Two Type

"FIBER OPTICS" (Letter Height 1" Min.)

Polymer Concrete Cover. Cover To Be Marked

Coil As Shown

Hand Hole Polymer Concrete

3 1/2"

PCC Apron* 12"

12"

2"

12" Min.

SIDE VIEW

Elbows Not Required In Hand Holes.

For Conduit Ends and Bushings), Typ.

For Cover Depth Exception & TM701 PVC or HDPE Conduit (See TM700 (See Note 4)

3/4" - 0" Crushed Rock

Coil As Shown

Grout Non-Shrink With Non-Epoxy Penetrations Seal Conduit

3"

3"

3" Min.

07-2025 REVISED FIBER OPTIC CABLE HAND HOLE INSTALLATION DETAIL

S

PCC Apron*

Chamfer (Typ.)

45 Degree

"1/23

Located In Driveable Surface Or As Shown *Install PCC Apron When Hand Holes Are

12" Max.

BA_PvmtDetails_Cover
BA_PvmtDetails_Klamath Falls WIM Sites
EA01
EA02
KA01
KA02
KB01
KB02
KB03
TM500A
TM500B
TM670
TM671
TM700
TM701
TM702
TM800
TM820
TM821
TM822
TM855

File details come from the government source that posted it. Updated .