Exhibit 5-Camp Grayling Training Pamphlet.pdf

PDF 5 MB Posted

Attached to
Molded Targets, Backer Board and Range Equipment
Solicitation number
RFP 511 260000001607 1
Issued by
Michigan

About this file

This is an exhibit supporting a state and local contract opportunity for Camp Grayling, a Michigan Army National Guard training facility, detailing molded targets, backer boards, and range equipment. The document is a comprehensive training pamphlet (CG PAM 25-8.1) cataloging 46+ ranges and training facilities at Camp Grayling, along with associated training aids, devices, simulators, and support infrastructure. The facility supports multi-echelon training from individual soldiers through battalion task force level, with capabilities spanning pistol, rifle, machine gun, grenade, mortar, artillery, armor, anti-armor, aerial gunnery, and urban warfare training. Specific range assets include automated target systems, backer boards in multiple configurations (white foam, green plastic), stationary and moving targets, and specialized equipment such as the M153 CROWS II Tabletop Gunnery Trainer, Virtual Battle Simulator (VBS3), and Engagement Skills Trainer (EST II). The facility includes 24 southern training areas and 30 northern training areas, with detailed grid coordinates, throughput capacities ranging from 6 to 66 soldiers per hour depending on range type, and comprehensive safety requirements aligned with AR 385-63 and CG 385-63 regulations.

The Camp Grayling facility encompasses approximately 147,000 acres of training space with airspace designated as R-4201A, R-4201B, and R-4202, supporting restricted operations requiring minimum 72-hour advance scheduling. Key infrastructure includes the Grayling Army Airfield with Class D airspace and instrument approach capabilities, 30 fuel pads distributed across cantonment and complex areas, multiple forward operating bases (FOB North and FOB South), drop zones, landing zones, and specialized training facilities such as the Combined Arms Collective Training Facility (CACTF), Live Fire Shoot House (LFSH), Counter-IED/Home Station Training Lane, and Urban Assault Course stations. Range scheduling is managed through RFMSS (Range Facility Management System), with units responsible for submitting Operations Plans and Deliberate Risk Assessment Worksheets 30 to 120 days prior to execution depending on range type. Environmental compliance, potable water locations, ammunition holding areas, and latrine facilities are designated throughout the installation, with units typically responsible for porta-john procurement and specialized equipment coordination such as MILES (Multiple Integrated Laser Engagement System) and LTIDS (Laser Training Instrumentation Detection System).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Camp Grayling Pamphlet 25-8.1

Information Management

Camp Grayling Range Control

Maneuver Training Center Camp Grayling, 49739 1 February 2026

Catalog of Ranges and Training Facilities o Updates Landing Zone (LZ) grid coordinates o Updates AFMAN 13-212 to CRTCMAN 13-212V1

Catalog of Ranges and Training Facilities o Updates signature and approval authority

This revision, dated 1 February 2026-o Provides clarification of range assets (throughout).

o Adds digging and earth moving in Chapter 2 o Adds Appendix M: Engineer Valley

SUMMARY of CHANGE

CG PAM 25-8.1

o Adds M153 CROWS II Tabletop Gunnery Trainer o Makes administrative changes (throughout).

o Adds Range 22: MK-19 Qualification & Familiarization o Changes to Range 12 primary function o Update to potable water locations o Updates to restrictions for Range 8 o Update to Appendix A: related publications o Updates and adds technical data in the text and tables (throughout).

o Updates to DODIC resrictions for Range 8

Camp Grayling Range Control

Maneuver Training Center

Bldg 545, Camp Grayling, 49739 Effective 1 January 2026

UNCLASSIFIED

Purpose: The Camp Grayling Catalog of Ranges is published to establish a comprehensive list of resources, training areas and ranges and their capabilities.

References: Refer to CG Reg 385-63 for scheduling facilities, training events and ranges on Camp Grayling for detailed information on requesting and scheduling facilities and ranges. Additional related publications and forms are listed in Appendix A.

Supplementation: This pamphlet cannot be supplemented without the approval of the Camp Grayling Director of Plans, Operations, Training and Security.

*This regulation supersedes CG PAM 25-8.1, 1 August 2024.

UNCLASSIFIED

*CG Pamphlet 25-8.1

Information Management

Catalog of Ranges and Training Facilities i

Pistol Classification Page

Range 1 Automated Combat Pistol 1 Range 2 25 meter paper target range 2

Shotgun Classification Page

Range 6A Familiarization & Qualification 6

Rifle (5.56mm) Classification Page

Range 3A 25 meter zero 3 Range 3B 25 meter zero 4 Range 6B 25 meter zero 7 Range 9A 25 meter zero 9 Range 11 Automated Record Fire (ARF) Qualification 11 Range 16 25 meter zero 16 Range 18 Automated Record Fire (ARF) Qualification 19 Range 19 Automated Record Fire (ARF) Qualification 20 Range 35 1000 yard Known Distance range 29

Machine Gun (5.56mm & 7.62mm) Classification Page

Range 3A 10 meter zero / familiarization 3 Range 8 MPMG(-) Automated Record Fire (ARF) Qualification 8 Range 9B 10 meter zero / familiarization 10

Machine Gun (.50 Plastic Rounds) Classification Page

Range 9B 10 meter zero / familiarization 10

Machine Gun (.50 Ball) Classification Page

Range 45 Zero & Qualification 42

Infantry Battle Course Classification Page

Range 5 Infantry Squad Battle Course 5 Range 12 Buddy / Team / Reflexive Fire 12 Range 39 Infantry Platoon Battle Course 30 Range 44 Squad Fire and Maneuver 41 Range 46 Company / Platoon Fire and Maneuver 43

Grenades Classification Page

Range 17 Fragmentation, HE 17 Range 17A Qualification, Practice Grenades ONLY 18

Drones Classification Page sUAS Program sUAS training and scenarios 31

Chapter 1: Ranges and Training Facilities By Type Table of Contents i

Grenade Launchers Classification Page

UAC-STA3 M203/M320 Familiarization (TP) 26 Range 15 M203/M320 Qualification 15 Range 22 MK-19 Qualification & Familiarization 23 Range 41 MK19 Familiarization 39

Mortars Classification Page

13 Complex Firing Points 60mm ONLY 13 Range 14 60mm Direct Lay 14 40 Complex- 500 Series Firing Points 60mm, 81mm & 120mm 47

Mines, Firing Devices & Charges Classification Page

13 Complex EOD Demolition 13 Range 20 Demolition Training 21 Range 21 Light Demolition Training 22 Range 35 Inert MICLIC 29 Range 43 Heavy Demolition Training 40

Armor Classification Page

Multi-Purpose Range Complex (MPRC) Tank Gunnery Tables 32

Anti-Armor Classification Page

Range 15 AT-4 Practice 15 Firing Point C4 TOW Inert / Live JAVELIN 44 Range 41 Live TOW (DODIC specific) / AT-4 39 Multi-Purpose Range Complex (MPRC) TOW Inert Qualification Tables 36

Artillery Classification Page

Range 35 MLRS / HIMARS 29 Multi-Purpose Range Complex (MPRC) MLRS / HIMARS 38 40 Complex 105mm and 155mm 46

Firing Point DF Direct Fire 45

Aerial Gunnery Classification Page

Air-To-Ground (STEELGATE) Fixed and Rotary Wing 49 Multi Purpose Range Complex (MPRC) Helicopter Aerial Gunnery 34 40 Complex Helicopter Door Gunnery 48

Urban Training Facilities Classification Page

CACTF Combined Arms Collective Training Facility 28 C-IED / HSTL Counter Improvised Explosive Device / 25

Training Facility / Home Station Training Lane LFSH Live Fire Shoot House 24 UAC Urban Assault Course; Stations 1, 2, 4 & 5 27

- 100 thru 400 and 600 Series Firing Points iii

Training Facility Classification Page

AFT Track 1 mile oval track 50 Airspace R-4201A, R-4201B, R-4202 51 CBRNE Training Facility Building 50 Digging & Earth Moving 52 Drop Zones 51 Engineer Bridge Sites 50 Forward Operating Base (FOB) North FOB (40 Complex) & South Camp FOB 50 Fuel Pads 51 Grayling Army Airfield Operations for military aircraft 51 Land Navigation Course Dismounted Day & Night Course 50 Landing Zones Operational & Medical LZs (Appendix K) 51 Parade Field 50 Potable Water Locations 52 Railhead 50 Rubble Pile Collapsed Structure Trainer 52 South Camp AHA Ammo Holding Area 51 Support Buildings 51 Training Areas Northern & Southern Complexes 52 UAS Runway 51 Water Operations Bridging & Water Purification 50

Training Aids, Devices, Simulators and Simulations (TADSS) Classification Page

CFFT Call For Fire Trainer 53 EST II Engagement Skills Trainer 52 IMT InVeris Marksmanship Trainer 53 CROWS II M153 Tabletop Gunnery Trainer 54 TC3X Tactical Combat Casualty Care Exportable System 53 UGT-I Unstabilized Gunnery Trainer-Individual 53 VCOT Virtual Convoy Operations Trainer 53 VBS3 Virtual Battle Simulator 53

Chapter 2: Additional Training Assets iv

Appendices: Page

Appendix A Section I: Publications 55 Section II: Forms 55 Section III: Websites 55

Appendix B Map of RNG05 - ISBC 56 Appendix C Map of UAC Stations 1 - 5 57 Appendix D Map of RNG32 - CACTF 58 Appendix E Map of MPRC 59 Appendix F Map of RNG39 - IPBC 60 Appendix G Firing Points 61 Appendix H OIC/RSO requirements per AR 385-63 62 Appendix J OIC/RSO requirements per CG 385-63 63 Appendix K Landing Zones 64 Appendix L Fuel Pad Locations 66 Appendix M Engineer Valley Dig Map 67

1)

2)

3)

4)

5)

6)

7)

8)

9)

Enclosed bleachers

RANGE 1 (RFMSS "RNG01")

Chapter 1: Ranges and Training Facilities

.45 cal, 9mm, .38 cal, .40 cal, .22 cal BALL

FIRING POINTS: 10 lanes with 6 targets per lane

FUNCTION: Automated Combat Pistol Qualification

RANGE ASSETS:

Target control tower Classroom Ammunition breakdown building

Throughput 20 Soldiers per hour

TARGETS: Automated target lifter mechanisms w/"E" Type silhouettes on site. There are no lights on targets. Units will supply their own chemical-lights to attach to targets for night fire.

Barricade requests must be submitted 90 days prior to execution.

Range gates must be manned or closed prior to and during "HOT" status.

OPERATOR: Coordinate with Range Control for instruction on computer operation.

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

LOCATION: 16TFQ 74031 44088

WEAPONS & AMMUNITION: Hand Guns

Note: Range is not compatable for LEWTAQ

Electricity Lights Automated target lifters Public Address (PA) System Heated latrine

3)

4)

5)

6)

7)

8)

Stationary Combat Pistol: 10 / 25 Meters M16/M4 Series Rifles 25 Meter Zero

.45 cal, 9mm, .38 cal, .40 cal, .22 cal BALL, 5.56mm

FIRING POINTS: 18

Throughput 36 Soldiers per hour

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RANGE 2 (RFMSS "RNG02")

FUNCTION:

LOCATION: 16TFQ 73760 44107

WEAPONS & AMMUNITION: Hand Guns, M4/M16

TARGETS: Green plastic and/or white foam backer boards provided for paper targets. Target requests must be submitted 90 days prior to execution. Range Control does not provide staple guns, staples or tape.

18 firing points with lighted overhead cover 18 pistol magazine tables

RANGE ASSETS:

Vaulted latrine Target storage shed, 24' x 24'

Lights

3)

4)

5)

6)

7)

8)

9)

Clearance to go down range beyond the 25 meter berm must be approved by Range Control prior to going beyond the berm.

FUNCTION:

RANGE ASSETS:

NO DE-LINKING AMMO

LOCATION: 16TFQ 73198 44021

WEAPONS & AMMUNITION: Rifles & Machine guns 5.56mm & 7.62mm ball

FIRING POINTS: 22

22 lanes for 25 meter firing

TARGETS: White foam backer boards provided for paper targets. Target requests must be submitted 90 days prior to execution. Range Control does not provide staple guns, staples or tape.

Bleachers Male/Female latrine located across road

NO TRACER ROUNDS FOR MACHINE GUN AMMUNITION

.50 cal (PLASTIC ROUNDS ONLY)

M16/M4 Series Rifles 25 Meter Zero

M240B and M2 10 Meter Table I and Familiarization Reflexive Fire

10 lanes for 10 meter firing

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTIONS:

M249 AR 10 Meter Zero

OIC Stand Ammunition breakdown building

RANGE 3A (RFMSS "RNG03A")

3)

4)

5)

6)

7)

8)

9)

Clearance to go down range beyond the 25 meter berm must be approved by Range Control prior to going beyond the berm.

NO DE-LINKING AMMO

RANGE ASSETS:

Vaulted latrine Target storage shed OIC Stand Ammunition breakdown building

5.56mm

FIRING POINTS: 43

25 meter firing points

TARGETS: Green plastic and/or white foam backer boards provided for paper targets. Target requests must be submitted 90 days prior to execution. Range Control does not provide staple guns, staples or tape.

10 meter firing points (20 firing points)

NO TRACER ROUNDS FOR MACHINE GUN AMMUNITION

NO 7.62 ball ammunition

LOCATION: 16TFQ 73291 44076

RANGE 3B (RFMSS "RNG03B")

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTIONS:

WEAPONS & AMMUNITION: Rifles & Machine guns

FUNCTION: M16/M4 Series Rifles 25 Meter Zero

3)

4)

5)

6)

7)

8)

9)

10)

Ammo breakdown building

2 moving infantry targets 2 trench obstacles 5 machine gun/observation bunkers

RANGE SAFETY: Unit will read and understand SOP associated with this range. OP Plan & DRAW must be approved 90 days to execution. One safety required for every 2 soldiers training. Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

CONFLICTS: Range closed when Range 6B or UAC STA3 are "HOT"

Covered mess

Latrine Enclosed bleachers

Classroom Facility

RANGE ASSETS:

Range operations center, tower Operations/storage building

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTIONS:

Forward limitation of Charlie Engagement when Ranges 8, 16, 18 or 19 are "HOT" M240B can only be utilized from a specific target box, subject to conflicts and CONOP review.

10 stationary infantry targets

LOCATION: 16TFQ 71840 43485 (See Appendix B for map)

WEAPONS & AMMUNITION: M/16/M4, M249, M240B, M203/M320

5.56mm, 40mm (TP ONLY)

FIRING POINTS: TBD based on OPLAN approval

Objective A: 16TFQ 71950 43837

Objective C: 16TFQ 71817 44289 Objective B: 16TFQ 71923 44183

7.62 (AB86 ONLY) (See restrictions below)

FUNCTION: Infantry Squad Battle Course (ISBC)

TARGETS: All targets are fully automated, and the event-specific target scenario is computer-driven and scored from the range operations center. The range operating system is fully capable of providing immediate performance feedback to the using participants.

4 stationary armor targets

RANGE 5 (RFMSS "RNG05 - ISBC")

3)

4)

5)

6)

7)

8)

9)

OIC stand / platform

RESTRICTIONS: Clearance to go down range beyond the 25 meter berm must be approved by Range Control prior to going beyond the berm.

RANGE ASSETS:

Vaulted latrine Barricades with window opening for qualification available

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

16 lanes for Qualification

FIRING POINTS: 16

TARGETS: "E" type silhouettes on staves. Target and barricade requests must be submitted 90 days prior to execution. Range Control does not provide staple guns, staples or tape.

WEAPONS & AMMUNITION: All Gauges of Shotguns

RANGE 6A (RFMSS "RNG06A")

FUNCTION: Shotgun Qualification and Familiarization Fire

LOCATION: 16TFQ 71252 43521

Target storage shed Ammunition breakdown building

3)

4)

5)

6)

7)

8)

9)

Enclosed bleachers

Vaulted latrine Ammunition breakdown building Target storage shed OIC stand / platform

5.56mm ball

TARGETS: White foam backer boards provided for paper targets. Target requests must be submitted 90 days prior to execution. Range Control does not provide staple guns, staples or tape.

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTIONS: Clearance to go down range beyond the 25 meter berm must be approved by Range Control prior to going beyond the berm.

RANGE ASSETS:

RANGE 6B (RFMSS "RNG06B")

FUNCTION: M16/M4 Series Rifle 25 Meter Zero

LOCATION: 16TFQ 71355 43500

WEAPONS & AMMUNITION: M16/M4 Rifles

FIRING POINTS: 30

Throughput: 60 Soldiers per hour

3)

4)

5)

6)

7)

8)

9)

10)

Heated classroom Ammunition breakdown building Covered mess area MR/briefing bleacher enclosure

Public Address (PA) System Indoor latrine

RESTRICTIONS:

OPERATOR: Coordinate with Range Control for instruction on computer operation.

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

FIRING POINTS: 10

TARGETS: Automated targets with lights, automated scoring and thermal targetry.

WEAPONS & AMMUNITION: Machine Gun 5.56mm and 7.62mm ball

Throughput: 20 Soldiers per hour

NO 300 WIN MAG or AA11

RANGE ASSETS:

Target control tower

.50 cal (PLASTIC ROUNDS ONLY) (A595, A602, A603)

7.62 DODICs (AB86) are restricted to lanes 2-7

A131 is restricted to lanes 2-4

RANGE 8 (RFMSS "RNG08 - MPMG")

FUNCTION:

LOCATION: 16TFQ 70302 43799

Multi-Purpose Machine Gun Range (MPMG) (-) 5.56mm & 7.62mm ball, Table II, Table Ill, and Familiarization Fire Center 4 lanes 1000 Meter Machine Gun Transition Firing

Sniper Course (up to 7.62mm only) Lanes 1 & 3 equiped for mounted vehicle firing points

3)

4)

5)

6)

7)

8)

9) RANGE ASSETS:

Vaulted latrine 24 x 24 storage building OIC stand / platform

FIRING POINTS: 20

Throughput: 40 Soldiers per hour

TARGETS: Green plastic backer boards provided for paper targets. Target requests must be submitted 90 days prior to execution. Range Control does not provide staple guns, staples or tape.

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTIONS: Clearance to go down range beyond the 25 meter berm must be approved by Range Control prior to going beyond the berm.

RANGE 9A (RFMSS "RNG09A")

FUNCTION: M16/M4 Series Rifle 25 Meter Zero

LOCATION: 16TFQ 69968 43917

WEAPONS & AMMUNITION: M16/M4 Rifles 5.56mm ONLY

3)

4)

5)

6)

7)

8)

9) RANGE ASSETS:

Target storage shed OIC stand / platform Enclosed bleachers Vaulted Latrines

FIRING POINTS: 20

Throughput: 40 Soldiers per hour

TARGETS: Green plastic backer boards provided for paper targets. Target requests must be submitted 90 days prior to execution. Range Control does not provide staple guns, staples or tape.

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTIONS: Clearance to go down range beyond the 10 meter berm must be approved by Range Control prior to going beyond the berm.

RANGE 9B (RFMSS "RNG09B")

FUNCTION: 10 Meter Machine Gun Zero / Familiarization

LOCATION: 16TFQ 69968 43917

WEAPONS & AMMUNITION: M16/M4 Rifles, M249 AR, M240B 5.56mm and 7.62mm .50 cal (PLASTIC ROUNDS ONLY)

3)

4)

5)

6)

7)

8)

9)

10)

Ammo breakdown building Target control tower Enclosed bleachers

RANGE ASSETS:

Vaulted latrine 24 x 24 Garage / Cold Storage Automated target lifter and scoring system Public Address (PA) System

Howe Rd. entrance gate must be manned or closed prior to and during "HOT" status.

OPERATOR: Coordinate with Range Control for instruction on computer operation.

FIRING POINTS: 10

Throughput: 20 Soldiers per hour

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

TARGETS: Range includes automated targets and scoring. IWQ regulation barricades are provided at all firing points. All targets are equipped with lights for night firing.

RESTRICTIONS:

No tracer rounds may be utilized on lanes 1, 2, 9 and 10 (exterior 2 lanes)

RANGE 11 (RFMSS "RNG11")

FUNCTION:

LOCATION: 16TFQ 69303 44024

WEAPONS & AMMUNITION: Rifle 5.56mm ball

M16/M4 Automated Record Fire (ARF) Qualification M249 AR Automated Record Fire (ARF) Qualification

3)

4)

5)

6)

7)

8)

9)

TARGETS: Green plastic backer boards provided for paper targets. Target requests must be submitted 90 days prior to execution. Range Control does not provide staple guns, staples or tape.

NO 7.62mm ammunition

Vaulted latrine 24 x 24 Shed OIC platform/stand

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTIONS:

RANGE ASSETS:

NO tracer rounds. Any requests will require an ETP.

WEAPONS & AMMUNITION: Hand Guns, M16/M4, M249, Shotgun .45 cal, 9mm, .38 cal, .40 cal, .22 cal 5.56mm

FIRING POINTS: 15 lanes

RANGE 12 (RFMSS "RNG12")

FUNCTION: LEWTAQ

LOCATION: 16TFQ 68272 45013

All Shotgun Gauges

Enclosed bleachers

3)

4)

5)

6)

7)

8)

9)

10)

NO OVERHEAD FIRING PERMITTED!

OP-B: 16TFQ 73160 38690OP-A: 16TFQ 73900 41200

OP-C: 16TFQ 73150 38650

Range requires restricted airspace when "HOT" which must be scheduled a minimum of 72 hours in advance

FP13-06: 16TFQ 74003 39924

FP13-07: 16TFQ 74014 39694

FP13-A2: 16TFQ 71493 39588

OBSERVATION POINTS: 3

Porta-John procurement is a unit responsibility Permanent excess propellant burning pan (Location: 16TFQ 73748 39794)

RANGE ASSETS: N/A

FP13-12: 16TFQ 72346 37783

FP13-15: 16TFQ 71620 40015

FP13-16: 16TFQ 72198 40528

FP13-A1: 16TFQ 71412 39340

RESTRICTIONS:

AT NO TIME ARE PERSONNEL ALLOWED TO ENTER THE DUDDED IMPACT AREA!

GATES AND ROADBLOCKS: Road guards with communications to the range OIC and roadblocks are required on the left and right limits of firing position(s). Road blocks must be manned prior to and during "HOT" status.

CONFLICTS: Firing Points conflict with Ranges 14, 15, or 17.

RANGE SAFETY: Units will receive approved, signed safety card/s from the Camp Grayling Range Officer prior to occupying the range. Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

TARGETS: Stationary targets, i.e. tank hulls and vehicles

FP13-08: 16TFQ 74159 39559

60mm TP, WP, HE, SMK & ILL

FP13-01: 16TFQ 73265 41148

FP13-02: 16TFQ 73593 41415

FP13-03: 16TFQ 78786 41037

FP13-04: 16TFQ 74006 40574

FP13-05: 16TFQ 73773 40139

FIRING POINTS: 16

FP13-09: 16TFQ 72165 38004

FP13-10: 16TFQ 72668 38680

FP13-11: 16TFQ 72501 37754

13 Complex Firing Points (Dud Impact Area)

FUNCTION: 60mm Mortar Live Fire and EOD disposal

WEAPONS & AMMUNITION: Mortars

3)

4)

5)

6)

7)

8)

9)

10) Porta-John procurement is a unit responsibility

CONFLICTS: Range 14 CANNOT be occupied if Range 15 is "HOT"

Coordinate with Range Control for the Safety Data Sheet

RANGE ASSETS:

RESTRICTIONS:

No personnel are allowed inside the fence while any firing points are "HOT"

Permanent excess propellant burning pan (Location: 16TFQ 73748 39794)

Range requires restricted airspace when "HOT" which must be scheduled a minimum of 72 hours in advance

RANGE 14 (RFMSS "RNG14")

FIRING POINTS: 2

TARGETS: Stationary Vehicle Hulls

FUNCTION: Direct Lay Mortar

LOCATION: 16TFQ 71464 39456

AMMUNITION: Mortar 60mm TP/HE/SMK

Range gates must be manned prior to and during "HOT" status.

RANGE SAFETY: Fire into designated areas only. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

3)

4)

5)

6)

7)

8)

9)

10)

Both ammo types are not authorized to be fired simutaneously

Range requires restricted airspace when "HOT" which must be scheduled a minimum of 72 hours in advance At no time are personnel allowed past the firing positions to go down range. This is a dudded impact area!

Range supports 4 inner lanes (4 stations each) of qualification with M203/M320 HE rounds or supports 4 outer lanes (4 stations each) of qualification with M203/M320 TP rounds.

Vaulted latrine OIC platform/stand

RANGE ASSETS:

Minimum safe engagement distances for HE 40mm rounds is 165 meters

Primary - M203/M320 Grenade Launcher Qualification Secondary - AT-4 Sub-caliber

AT 4 Sub-caliber ONLY (9mm)

M203/M320: 4 lanes with 4 positions (8 per hour) AT-4 Sub-Caliber: 5 lanes (10 per hour)

FIRING POINTS:

Range gates must be manned prior to and during "HOT" status.

RESTRICTIONS:

TARGETS: Zero Panel, 1-Man Bunker, 2-Man Bunker, 3-Man Machine Gun Position, Window Target, and Troops In Open

CONFLICTS: Range 15 CANNOT be utilized if Range 14 or the 13 Complex are "HOT"

RANGE 15 (RFMSS "RNG15")

FUNCTION:

LOCATION: 16TFQ 72326 40717

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Target requests must be submitted 90 days prior to execution. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

WEAPONS & AMMUNITION: M203/M320 Grenade Launcher 40mm TP, ILL, HE, & SMK

3)

4)

5)

6)

7)

8) Vaulted latrine OIC platform/stand Foot path available to access ARF Ranges 18 & 19 Ammunition breakdown building Target storage shed

TARGETS: White foam backer boards provided for paper targets. Target requests must be submitted 90 days prior to execution. Range Control does not provide staple guns, staples or tape.

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RANGE ASSETS:

WEAPONS & AMMUNITION: Rifle 5.56mm ball

FIRING POINTS: 33

Throughput: 66 Soldiers per hour

RANGE 16 (RFMSS "RNG16")

FUNCTION: M16/M4 Series Rifles 25 Meter Zero

LOCATION: 16TFQ 69157 47701

Enclosed Bleachers

3)

4)

5)

6)

7)

8)

9)

FIRING POINTS: Three (3) throwing bays Throughput: 6 Soldiers per hour

RANGE SAFETY: Impact area is within the berm area. DO NOT THROW GRENADES OUT OF THE CLEARED AREA. Other safety features are left and right limit markers. NO CROSS LANE THROWING! Scarlet streamers are to be displayed during firing. Reference CG 385- 63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

GATES AND ROADBLOCKS:

Gate going into range (impact area) must be manned prior to and during "HOT" status.

CONFLICTS: CANNOT "OCCUPY" when mortars are being fired.

RANGE 17 (RFMSS "RNG17 - LIVE GRENADE")

FUNCTION: Hand Grenade Familiarization

LOCATION: 16TFQ 73780 39781

AMMUNITION: Hand Grenades, fragmentation

RESTRICTIONS:

At no time are personnel allowed beyond the throwing positions This is a DUD impact area No night time operations

RANGE ASSETS:

Vaulted latrine Observation bunker

Winter operations may be impeded by snow restrictions

Range requires restricted airspace when "HOT" which must be scheduled a minimum of 72 hours in advance

3)

4)

5)

6)

7)

8)

9)

TARGETS: Each station has a different objective associated with qualification.

No night time operations

RANGE ASSETS: N/A

Porta-John procurement is a unit responsibility

RANGE SAFETY: Unit specific Deliberate Risk Assessment Worksheet. Reference CG 385- 63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTIONS:

PRACTICE grenades only, no fragmentation grenades allowed

RANGE 17A (RFMSS "RNG17A - HAND GRENADE QUAL")

FUNCTION: Hand Grenade Qualification Course Designed to meet the standards of FM 23-30

LOCATION: 16TFQ 73826 40000

AMMUNITION: Hand Grenades - PRACTICE GRENADES ONLY!

FIRING POINTS: 7 stations Throughput: 14 Soldiers per hour

3)

4)

5)

6)

7)

8)

9)

10)

No tracer rounds may be utilized on lanes 1, 2, 8 and 9

RANGE 18 (RFMSS "RNG18")

LOCATION: 16TFQ 69083 47476

WEAPONS & AMMUNITION: M16/M4 Rifles, M249 AR 5.56mm ball

FUNCTION:

M16/M4 Automated Record Fire (ARF) Qualification

Covered mess area

Target control tower Foot path available from Range 16

M249 AR Automated Record Fire (ARF) Qualification

FIRING POINTS: 6

Throughput: 12 Soldiers per hour

TARGETS: Range includes automated targets and scoring. IWQ regulation barricades are provided at all firing points. All targets are equipped with lights for night firing.

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Automated target lifter and scoring system Public Address (PA) System Ammo breakdown building

RANGE ASSETS:

M / F latrine, block building

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTION: DO NOT go down range without approval from Range Control

OPERATOR: Coordinate with Range Control for instruction on computer operation.

3)

4)

5)

6)

7)

8)

9)

10)

No tracer rounds may be utilized on lanes 1, 2, 15 and 16 RESTRICTION: DO NOT go down range without approval from Range Control

LOCATION: 16TFQ 69697 47969

WEAPONS & AMMUNITION: Rifle 5.56mm ball

FIRING POINTS: 16

Throughput: 32 Soldiers per hour

TARGETS: Range includes automated targets and scoring. IWQ regulation barricades are provided at all firing points. 50 Meter targets are equipped with lights for night firing.

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

OPERATOR: Coordinate with Range Control for instruction on computer operation.

RANGE ASSETS:

M / F latrine, block building Covered mess area Automated target lifter and scoring system Public Address (PA) System Ammo breakdown building Target control tower Foot path available from Range 16

RANGE 19 (RFMSS "RNG19")

Range gates must be manned or closed prior to and during "HOT" status.

FUNCTION:

M16/M4 Automated Record Fire (ARF) Qualification

3)

4)

5)

6)

7)

RESTRICTION:

NO STEEL CUTTING, UTILIZE RANGE 21

DD 3020 PLAN MUST BE TURNED IN TO RANGE CONTROL FOR APPROVAL NLT

30 DAYS PRIOR TO OCCUPATION OF THIS RANGE

AMMUNITION:

1 pound frag producing 10 pounds or less shaped charges (downward facing)

TNT, C-4, COMP B, DET CORD, TIME FUSE, BLASTING CAPS, SHAPED CHARGES,

& AP MINES.

RANGE SAFETY: The following requirements are dependant on materials being utilized.

Blasting caps will be stored at least 100 meters from ammunition and explosives. No smoking within 100 meters of ammunition and explosives. All personnel will wear approved ballistic helmets, IBA (body armor), eye protection, and hearing protection on this range at all times. Scarlet streamer is to be displayed during daylight and flashing red light during night use. A five minute blast window must be radioed to the fire desk prior to detonation.

Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical

Front Gate to range must be manned and back gate must be locked Range gates must be manned prior to and during "HOT" status.

FUNCTION: Demolition Range

LOCATION: 16TFQ 70452 43048

RANGE 20 (RFMSS "RNG20")

Demolitions shall not exceed:

20 pounds bare charge (non frag producing)

Demo prep tables Cement bunker Porta-John procurement is a unit responsibility

RANGE ASSETS:

3)

4)

5)

6)

7)

Re-fill holes and police all materials off range

Abatis training site

RANGE SAFETY: As required for materials being used. Pits will be located so firers see all other pits and the immediate vicinity of the pits. Blasting caps will be stored at least 100 meters from ammunition and explosives. No smoking within 100 meters of ammunition and explosives. All personnel will wear approved protective helmets, IBA, eye protection, and single hearing protection on this range at all times. Scarlet streamer is to be displayed during daylight and flashing red light during night use. A five minute blast window must be radioed to the fire desk prior to detonation. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

RANGE 21 (RFMSS "RNG21")

FUNCTION: Light Demolition Range

LOCATION: 16TFQ 69306 41649

AMMUNITION:

TNT, C-4, COMP B, DET CORD, TIME FUSE, BLASTING CAPS, SHAPED CHARGES

Porta-John procurement is a unit responsibility

Steel cutting is only authorized in designated chamber

Covered mess area

DD 3020 PLAN MUST BE TURNED IN TO RANGE CONTROL FOR APPROVAL NLT

30 DAYS PRIOR TO OCCUPATION OF THIS RANGE

RANGE ASSETS:

Two Viewing bunkers Demo prep area Ammunition Breakdown Building

Range gates must be manned prior to and during "HOT" status.

RESTRICTION:

5 pounds or less shaped charges (downward facing) 1 pound frag producing

Steel cutting chamber

5 pounds bare charge (non frag producing) Demolitions shall not exceed:

3)

4)

5)

6)

7)

8)

9) RANGE ASSETS:

Elevated firing berm Latrine procurement is a unit responsibility

600m (M113’s) 1500m (M113’s) 900m (M113’s)

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red light during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned prior to and during "HOT" status.

RESTRICTIONS:

Range requires restricted airspace when "HOT" which must be scheduled a minimum of 72 hours in advance MK-19 night fire is NOT AUTHORIZED Firing line is located inside boundary of impact area. Only authorized movement is between range gate and designated firing line.

FIRING POINTS: 3 lanes

TARGETS: Stationary vehicle hulls.

400m (M113’s) 1200m (M113’s)

RANGE 22 (RFMSS "RNG22")

FUNCTION: MK-19 Qualification & Familiarization

LOCATION: 16TFQ 72466 39297

WEAPONS & AMMUNITION: MK-19, LAW, AT-4, SMAW, 84mm Carl Gustav 40mm TP ONLY

3)

4)

5)

6)

7)

8)

RANGE LFSH (RFMSS "LFSH")

FUNCTION: Live Fire Shoot House (LFSH)

LOCATION: 16TFQ 72891 43783

WEAPONS & AMMUNITION: Pistols & M4/M16 .45 cal, 9mm, .38 cal, .40 cal, .22 cal

5.56 ball / Enhanced Performance Round (EPR)

FIRING POINTS: Scenario driven with prior approval from Range Control

Unit Commander must complete LFSH SOP APPENDIX D (Automated Shoot House Certification Letter) and must comply with LFSH SOP APPENDIX E (Medical Emergencies)

RANGE SAFETY: OPLAN and DRAW must be submitted to Range Control 90 days prior to execution. Scarlet streamers are to be displayed during daytime firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

RESTRICTIONS:

CANNOT go "HOT" without Range Control approved OPLAN and DRAW

NO 7.62mm ammunition Requires a medic (68W) to be on site while in a "HOT" status

E-SAPI Plates are required for DoD Units

RANGE ASSETS:

M / F latrine Ammunition breakdown building Outdoor covered mess

3)

4)

5)

6)

7)

8)

Mounted IED Visual Indicator Lane (MIVIL) Dismounted IED Visual Indicator Lane (DIVIL) Vaulted and facility latrines with hand washing stations

Subterranean operations

24 total buildings: 8 two-story, 16 single-floor multi-room buildings formed into a foreign city mock-up

Observation tower

Counter IED / HSTL (RFMSS "IED_DEFEAT")

FUNCTION:

LOCATION: 16TFQ 68052 43450

To assist unit Commanders with developing scenarios that meet the unit’s requirements for individual and collective tasks for pre-mobilization training.

Develop and coordinate training events while integrating Asymmetric Warefare tasks into scenario driven training.

Assist senior staff with the development of custom scenarios based on the unit's specific mission and expected area of operation in accordance with current Tactics, Techniques and Procedures (TTPs).

Classes offered are IED-Awareness, Dismounted Operations, Mounted Operations, Home-made Explosives, Hybrid Theory, C-UAS/UAS, Subterranean Operations, Ukraine Conflict Brief, Russian Brief and other unit specific tailor-made courses.

Unmanned Aircraft Vehicle (UAV) are available to support troops on the ground with access to areas of operation that may be hazardous on a battlefield in a training environment.

WEAPONS & AMMUNITION: M9, M16/M4, M249, M240B, M2

Blanks

Five miles of road network with a traffic circle and overpass

RANGE ASSETS:

RESTRICTIONS: NO LIVE AMMUNITION

AAR / Instruction building

RANGE SAFETY: Scarlet streamers are to be displayed during daytime firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Range gates must be manned or closed prior to and during "HOT" status.

Six square miles of training area

FIRING POINTS: Tailor-made scenario driven lanes

Simunition rounds Less-than-Lethal

FOB operating base on hill top

3)

4)

5)

6)

7)

8)

9)

Do not shoot 5.56 at the building facade

Porta-John procurement is a unit responsibility

No personnel will go down range farther than last firing position without approval from Range Control Live fire events close Range 5 NO 7.62mm ammunition

NO M249

NO MK-19

RANGE ASSETS:

Control tower Ammunition breakdown building

Urban Assault Course - Station 3 (RFMSS "UAC_STA3")

FUNCTION: Grenadier Gunnery Trainer

WEAPONS & AMMUNITION: M16/M4, M203/M320

5.56mm & 40mm (TP ONLY)

FIRING POINTS: 2 lanes, scenario driven with approved CONOP

TARGETS: Automated "E" type silhouette.

RANGE SAFETY: OPLAN and DRAW must be submitted to Range Control 90 days prior to execution. Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

RESTRICTIONS:

Range gates must be manned or closed prior to and during "HOT" status.

LOCATION: 16TFQ 72891 43783 (See Appendix C for map)

Station 3 - Grenadier Gunnery Trainer, a live-fire station designed for M203 gunners to practice and master target engagements in an urban setting. This training area includes a two-story facade and various firing positions to simulate a realistic environment for tactical movement and responding to fire commands. The station is used for live-fire training with small arms and 40-mm training practice grenades.

3)

4)

5)

6)

Urban Assault Course (UAC) Stations 1, 2, 4, 5

AAR / Instruction building Bleachers M / F Latrines Covered Mess Area

RANGE ASSETS: All assets located near Station 5 entrance

Range gates must be manned prior to and during "HOT" status.

FUNCTION:

Station 1 – Individual & Team Trainer; used to train individual and collective tasks, tactics, techniques and procedures, such as entering a building, clearing a room and engaging targets. This structure is comprised of three rooms, which have open doorways and windows

Station 2 - Squad & Platoon Trainer; used to build upon tasks learned at Station 1 and begin to learn the concepts of clearing multiple buildings increasing the complexity of command, control, and maneuver. This station is equiped with multiple rooms and designed to replicate separate buildings with a narrow street or as individual rooms inside a building with a long, connecting hallway. This station has four separate structures that face inward to create a street and introduces a two-story building with both exterior and interior stairways and catwalks.

Station 3 - Grenadier Gunnery Trainer (See page 26 for details)

Station 4 - Urban Offense/Defense Trainer; used to train platoons to attack and/or defend a building. Station 4 can also be divided into a number of smaller training stations to reinforce training or to train tasks not yet trained at the other stations. It allows the platoon

Station 5 - Underground Trainer, used to provide training for subterranean operations and designed to train up to a squad on clearing and moving tactically in a subterranean environment. Station 5 also contains an Enemy Prisoner-of-War training site. It contains 30,000 sq ft area surrounded by a double cyclone fence topped with barbed wire along with 2 two-story buildings with breachable doors. Units must supply their own dowel rods for the breachable doors.

WEAPONS & AMMUNITION: M16/M4, M249, M240B, M2

RANGE SAFETY: Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

LOCATION: (See Appendix C for map)

Station 2 (RFMSS "UAC_STA2") GRID: 16TFQ 73023 43489

BLANKS ONLY

Station 5 (RFMSS "UAC_STA5") GRID: 16TFQ 73246 43642 Station 4 (RFMSS "UAC_STA4") GRID: 16TFQ 73098 43887

Station 1 (RFMSS "UAC_STA1") GRID: 16TFQ 73243 43508

3)

4)

5)

6)

7) 23 various buildings Mouse and loop holes Roads, alleys, parking areas, athletic field and parks Underground sewer network Elevator shaft for fast roping (with advanced notice) Helicopter LZ Rappel anchors at the Embassy (Bldg A4) (GRID: 16TFQ 86686 52885)

Rubble Pile (GRID: 16TFQ 86924 52795). Scheduled seperately in RFMSS.

RANGE 32 (RFMSS "RNG32 - CACTF")

FUNCTION: Combined Arms Collective Training Facility (CACTF)

LOCATION: 16TFQ 86628 52853 (See Appendix D for map)

WEAPONS & AMMUNITION: Hand Guns, M16/M4, M249, M240B, M2

BLANK & NON-DUDDED DODICS ONLY

Smoke and Flash Bang Grenades Simulation Door Breaching Charges

The CACTF is designed to conduct multi-echelon training up to battalion task force (TF) level.

It replicates an urban environment which consists of 23 buildings, vehicular and pedestrian circulation systems and an underground trainer designed to evaluate unit urban operations proficiency. The facility consists of 2.25 square kilometers and is designed to support heavy and light infantry, armor, artillery, and aviation positioning and maneuver in a non-live fire environment. The CACTF supports combined arms training across the following operations:

offense, defense, stability, and support. Units must supply their own dowel rods for the breachable doors.

Multi-Integrated Laser Engagement System (MILES) Special Effects Small-Arms Marking System (SESAMS) Man Marker Round (MMR) also know as (UTM) / SIMUNITIONS

Range gates must be manned or locked prior to and during "HOT" status.

RESTRICTIONS:

RANGE ASSETS:

No smoke grenades inside of buildings

RANGE SAFETY: Scarlet streamers are to be displayed during daytime firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

Rappel anchors at the Hotel (Bldg A18) (GRID: 16TFQ 86650 52868) Bridging location (GRID: 16TFQ 86906 52917)

2 x Vaulted latrine All buildings have power

Helicopters can only fast rope onto flat roofed buildings

3)

4)

5)

6)

7)

8)

9)

10)

Covered bleachers

RESTRICTIONS:

RANGE ASSETS:

NO MACHINE GUNS

NO DUD PRODUCING ROUNDS

NO INDIRECT FIRE SYSTEMS

CONFLICTS: Range cannot be occupied when HIMARS/MLRS are firing.

Ammunition breakdown building

24 x 24 Target storage building Open tower

When Small Fan is closed, 1 vehicle, 2 personnel When Large Fan is closed, 2 vehicle, 4 personnel Road guards required on Bald Hill Rd. when Extended Fan is closed

Stationary carriages Iron Maidens available by request Infantry targets on staves by request

Range requires restricted airspace when "HOT" which must be scheduled a minimum of 72 hours in advance

Vaulted latrine

Target requests must be submitted 30 days prior to execution

When firing MICLIC, 4 road guards are required

5.56mm, 7.62mm, .338 Lapua, .50cal

FIRING POINTS: 10

Throughput 20 Soldiers per hour

TARGETS:

RANGE SAFETY: Left and right limit markers. NO CROSS LANE FIRING! Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

RANGE GATES AND ROAD BLOCKS:

Depending on the weapon system being used, the following gate guards will be required:

RANGE 35 (RFMSS "RNG35 - KD")

FUNCTION:

LOCATION: 16TFQ 87549 51240

WEAPONS & AMMUNITION: Sniper Rifle, Rifle, MICLIC Practice Rocket

Primary - 1,000 yard Known Distance range Secondary - Detonation of Mine Clearing Line Charge (MICLIC - INERT ONLY)

3)

4)

5)

6)

7)

8)

9)

10)

RANGE GATES AND ROAD BLOCKS:

Depending on the weapon system being used, the following gate guards will be required:

When Small Fan is closed, 1 vehicle, 2 personnel When Large Fan is closed, 2 vehicle, 4 personnel Road guards required on Bald Hill Rd. when Extended Fan is closed

Covered Mess

Covered Bleachers

RANGE ASSETS:

Ammo Holding Area

RESTRICTIONS:

NO INDIRECT FIRE SYSTEMS AUTHORIZED

CONFLICTS: Range cannot be occupied when HIMARS/MLRS are firing Use of MPRC or MICLIC closes range, unless prior coordination is made with 30 Complex Range NCOIC for co-use.

Forward limitation of Charlie Engagement when Range 35 is "HOT"

NO DUD PRODUCING ROUNDS

Vaulted latrine Enclosed tower

Range requires restricted airspace when "HOT" which must be scheduled a minimum of 72 hours in advance

40mm (Non Dud Producing TP ONLY)

Automated Stationary Armor Targets

RANGE 39 (RFMSS "RNG39 - IPBC")

FUNCTION: Infantry Platoon Battle Course (IPBC)

FORTS® Mobile Shelters 38 Model

TARGETS:

Stationary Infantry Target (SIT) Moving Infantry Target (MIT)

LOCATION: 16TFQ 87623 53615 (See Appendix F for map)

WEAPONS & AMMUNITION: Rifle, Machine Gun and M203/M320

FIRING POINTS: TBD based on OPLAN approval

SMAW (INERT ONLY)

Practice Grenade

Objective A: 16TFQ 88092 53759 Objective B: 16TFQ 88703 54230 Objective C: 16TFQ 89054 54450

Objective D: 16TFQ 90517 54886 Objective E: 16TFQ 91032 55057 Objective F: 16TFQ 91380 55454

7.62 ball and tracer 5.56mm ball and tracer

RANGE SAFETY: OP Plan & DRAW must be approved and submitted 90 days prior to execution . One safety required for every squad training. Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance.

Reference Appendix H and J for OIC, RSO and medical requirements.

3)

4)

5)

LOCATION:

RANGE 32: CACTF (16TFQ 8670252822)

BLDG 3201-R (16TFQ 8622552932)

RANGE SAFETY:

Small UAS (sUAS) Program

FUNCTION:

Primary mission of the office is to create and enhance sUAS capabilities.

Assist unit commanders with sUAS training and scenarios to meet their individual and collective tasks.

Assist senior staff with briefings regarding sUAS, uses, TTPs, region specific threat assessment information, and development of scenarios to incorporate sUAS capabilities and threats.

Provide additional training and experience to enhance mission and MOS related capabilities. These can include skills such as mapping, ISR, radio networks, TAK integration, and similar.

Act as a resource to sUAS operators and leadership on regulations, requirements, best practices, and information.

Black Hornet 3

Indoor heated latrine located at 3201-R

Skydio 2+

2 x Vaulted latrine located at Range 32

Submit airspace / UFOR request form to Range Control. SOP and forms are located in the RFMSS library.

Ensure sUAS operators are properly designated on the unit's Range Certification memo filed with Range Control.

RESTRICTIONS:

RANGE ASSETS:

AAR Classroom (GRID: 16TFQ 86238 52942) Wi-Fi enabled

Skydio X2D (RQ-28A)

If only doing sUAS flight training / operations, only an OIC and sUAS operator are required.

May require restricted airspace, which must be scheduled a minimum of 72 hours in advance

3)

4)

5)

6)

7)

Charlie Lane:

8 Defensive Defilade Positions (4 on each lane) 6 Offensive Fire Boxes (3 on each lane road)

Unit is responsible for requesting MILES from the TSC 120 days in advance.

Unit is responsible for requesting LTIDS from the 30 Complex Range Staff 90 days in advance and is responsible for providing the LTIDS batteries and velcro to attach to requested targets.

Alpha Lane:

4 Moving Armor Targets

Charlie Lane:

16 Stationary Armor Targets

The use of the Multiple Integrated Laser System (MILES) has the same requirements for use as a live fire exercise, with the following exceptions & requirements:

19 Stationary Armor Targets

TARGETS:

RANGE SAFETY: Left and right limit markers. Scarlet streamers are to be displayed during daylight firing and flashing red lights during night fire. Reference CG 385-63, AR 385-63, DA PAM 385-64 and appropriate FMs, TCs and TMs for further safety guidance. Reference Appendix H and J for OIC, RSO and medical requirements.

4 Moving Armor Targets

MPRC: TANK GUNNERY (RFMSS "MPRC")

FUNCTION: Tank Table Qualification / Tank Crew Proficiency

LOCATION: 16TFQ 87696 53843 (See Appendix E for map)

WEAPONS & AMMUNITION: Rifles, Machine Guns and Tanks

105mm / 120mm SABOT INERT

8 Defensive Defilade Positions (4 on each lane) 6 Offensive Fire Boxes (3 on each lane road)

MANEUVER LANES: 2

5.56mm, 7.62mm ball & tracer .50 cal ball & tracer

Alpha Lane:

LFX/STX training OPLAN and DRAW must be submitted to Range Control NLT 90 Days prior to execution.

RANGE GATES AND ROAD BLOCKS:

Depending on the weapon system being used, the following gate guards will be required:

When Small Fan is closed, 1 vehicle, 2 personnel When Large Fan is closed, 2 vehicle, 4 personnel Road guards required on Bald Hill Rd. when Extended Fan is closed

8)

9)

10)

CONFLICTS: Use of MPRC closes some 600 series firing points

Tank loading dock

Covered bleachers Ammunition breakdown building Ellis Tower

RANGE ASSETS:

Vaulted latrine

NO DUD PRODUCING ROUNDS

NO INDIRECT FIRE SYSTEMS AUTHORIZED

NO AP/API ROUNDS

RESTRICTIONS:

Range requires restricted…