Exhibit_4_-_ESHC_Fencing_Specifications.pdf
PDF 283 KB Posted
- Solicitation number
- BPM050831
- Issued by
- Dorchester County, Capitol Heights Town, Maryland
About this file
This document is a Fencing Specifications Exhibit from the Maryland Department of Health, detailing technical requirements for a fencing project. The specifications cover a single-layered mesh fence system with a total length of 150 feet, 8-foot panel width, and 12-foot height. The project requires a mandatory site visit before proposal submission, with the fence terminating and anchoring to a building. Two post configuration options are provided (square and round), and the fence includes a 4-foot wide by 7-foot high lockable gate with specific installation requirements.
The fencing must meet rigorous technical standards, including ASTM F1043 Group IA Heavy Industrial Fence Framework specifications, schedule 40 galvanized pipe, and specific wire mesh characteristics. Additional requirements include a powder coat black finish, 3,000 PSI concrete footings, wind speed resistance up to 110 MPH, and a minimum 20-year warranty against manufacturing defects. The project emphasizes precise installation details such as fabric tension, ground clearance, and attachment methods, with no additional lighting or security cameras required beyond existing infrastructure.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Exhibit_4_-_ESHC_Fencing_Specifications_Revised.pdf | ||
| Exhibit_2_-_Concrete_Mow_Strip_Specification.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Panel type:
FENCING SPECIFICATIONS EXHIBIT # 4
Single layered mesh system.
Panel type Image:
Fence Length: 150’-0” (Field Verify)
Panel Width: 8’- 0”
Fence Height: 12’- 0”
Rails: 3 (three), Top, Bottom, and Intermediate - round steel pipe rails: ASTM F1043
Group IA Heavy Industrial Fence Framework, schedule 40 galvanized pipe per
ASTM F1083.
Wire diameter: 0.15 in (3/20 of an inch)
Mesh size: 3” x 3/8” - 11 gauge. Shall meet or exceed ASTM F2781 test results. Chain Link
Fabric: Install fabric to inside of the framework, post and ties on the outside.
Attach fabric to the terminal post by threading the tension bar through the fabric;
secure the tension bar to the terminal post with tension bands and carriage bolts spaced no greater than 12 inches (304.8mm) on center. Attach to terminal post by sandwiching the mesh between the post and a vertical 2 in. wide (50mm) by
3/16 in. (4.76 mm) galvanized steel bar. Chain link fabric to be sufficiently stretched to taut so as not to deflect more than 3 in. (76 mm) in the center of two-line post at mid height subjected to a 30 lb. (133N) horizontal force. Fabric to be secured to the line post with tie wires spaced no greater than 12 inches
(304.8 mm) on center and to rail spaced no greater than 12 inches (304.8 mm) on center. The installed fabric shall have a ground clearance of no more than 2 inches (50 mm).
Finish: Powder Coat Finish – Color: Black
Panel installation: Bottom of panel maximum 2” above ground (Mow Strip).
OPTION A – Square Post dimensions:
Intermediate post 4” square steel pipe: ASTM F1043 Group IA Heavy Industrial Fence
Framework, schedule 40 galvanized pipe per ASTM F1083.
Corner Post: 6” square steel pipe: ASTM F1043 Group IA Heavy Industrial Fence
Framework, schedule 40 galvanized pipe per ASTM F1083.
Gate Post: 4” square steel pipe: ASTM F1043 Group IA Heavy Industrial Fence
Framework, schedule 40 galvanized pipe per ASTM F1083.
Rails: Top Rail, Intermediate Rail, and Bottom Rail: 2” square steel pipe: ASTM
F1043 Group IA Heavy Industrial Fence Framework, schedule 40 galvanized pipe per ASTM F1083.
OPTION B – Round Post dimensions:
Intermediate post 4” diameter - round steel pipe: ASTM F1043 Group IA Heavy Industrial Fence
Framework, schedule 40 galvanized pipe per ASTM F1083.
Corner Post: 6” diameter - round steel pipe: ASTM F1043 Group IA Heavy Industrial Fence
Framework, schedule 40 galvanized pipe per ASTM F1083.
Gate Post: 4” diameter - round steel pipe: ASTM F1043 Group IA Heavy Industrial Fence
Framework, schedule 40 galvanized pipe per ASTM F1083.
Rails: Top Rail, Intermediate Rail, and Bottom Rail: 2” diameter - round steel pipe:
ASTM F1043 Group IA Heavy Industrial Fence Framework, schedule 40 galvanized pipe per ASTM F1083.
Gate: 4’-0” wide x 7’-0” height, Schedule 40, Lockable, No gaps between gate and adjacent fence
Lockable: Keyed on both sides. Mortised Lock. Interchangeable core. 1 (one) Door Handle, located on the outside
Gate Foundation: 3,000 PSI Concrete footing, approximately 6’-0” long x 2’-0” wide x 3’-0” deep.
4” Post Foundations: 3,000 PSI Concrete footing. approximately 5’-0” deep x 1’-8” diameter
Mow strip: Refer to attached detail. (Exhibit # 4)
Wind Speed: 110 MPH.
Warranty: Minimum of 20 years against manufacturing defects.
Special condition: 1 (one) site visit required before submitting a proposal. Contact the hospital representative to set up a site visit date. The termination of the fence will be anchored to the building. The Fence needs to drop underneath the soffit/eave when it approaches the building. The soffit/eave is lower than 12’-0”. Visit the site and provide a proposed detail to address this issue. Explain in a narrative and include a detail showing how you intend to frame and secure the fence to the building when it drops under the soffit/eave.
Notes:
1. All dimensions are nominal.
2. No lighting required
3. No Security Camera’s required.
4. Existing Camera will be relocated by the facility.