Exhibit_1.pdf
PDF 73 KB Posted
- Attached to
- De-Ionization System Cylinder Maintenance
- Solicitation number
- IFB26-0050
- Issued by
- Orange County, Orlando City, Florida
About this file
This document is Exhibit 1, a flow diagram for de-ionization systems associated with IFB26-0050, issued by the Procurement and Contracts Division. The exhibit details water filtration processes for three distinct locations: Iron Bridge Laboratory, Iron Bridge Operations, and Water Conserv II. Each location follows a comprehensive multi-stage water purification process that includes tap water intake, filtration through various micron-rated filters, water softening, carbon tank treatment, reverse osmosis (R.O.) membrane processing, storage, and final polishing through de-ionization (D.I.) tanks and ultraviolet (U.V.) light treatment before reaching the laboratory.
The flow diagram provides a technical schematic of water treatment systems, demonstrating a sophisticated approach to water purification that progressively removes impurities through multiple filtration stages. Each system uses similar core technologies but with slight variations in the number of filtration tanks, membrane types, and post-processing steps. The diagram shows consistent use of 1-micron and 0.2-micron filters, water softeners, carbon tanks, R.O. membranes, storage tanks, pumps, and U.V. light treatment, indicating a standardized yet tailored approach to water preparation for laboratory environments.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| De-Ionization_System_Cylinder_Maintenance.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
De-ionization System Cylinder Maintenance IFB26-0050
Procurement and Contracts Division Page: 1
EXHIBIT 1
FLOW DIAGRAM FOR DE-IONIZATION SYSTEMS
1. IRON BRIDGE LABORATORY
Tap Water → 20” Filter, 1 micron → Pump → Water Softener → Carbon Tank →
10” Filter, 1 micron → R.O. Pre-Filter, 1 micron, 10”, → R.O. Membrane and 9-7/8” 1 micron filter → Storage Tank With Vent, 10” Filter, 0.2 micron, → Pump → D.I. Tanks (three) → Re-circulating Pump → D.I. Tank (1), polishing → U.V. Light → 20” Post Filter 0.2 micron →
LAB
2. IRON BRIDGE OPERATIONS
Tap Water → Pump → 20” Filter, 1 micron → Water Softener → Carbon Tank →
R.O, 10” Pre-Filter, 1 micron, → R.O. Membrane → Storage Tank → Pump →
10” Filter, 0.2 micron, → D.I. Tanks (two) → LAB
3. WATER CONSERV II
Tap Water → 20” Filter, 1 micron → Water Softener → Carbon Tank →
R.O. Pre-Filter, 1 micron, 10” → R.O. Membrane → Storage Tank With Vent, Filters (two), 0.2 micron, → Re-circulating Pump → D.I. Tank (4) → Big Blue 15-1
Filters (three), 0.2 micron, → U.V. Light → LAB