Exhibit 1.Oden Iso Building PV Map.pdf

PDF 954 KB Posted

Attached to
Addendum #4 RFP-DNR- PPA for Oden Isolation Bldg-
Solicitation number
RFP 751 200000001376 5
Issued by
Emmet County, Michigan

About this file

This is an exhibit map from the Department of Natural Resources (DNR) depicting the Oden Iso Building photovoltaic (PV) array installation site. The map outlines proposed solar panel locations and associated infrastructure, including two representative PV arrays of approximately 5,000 square feet and 50 kilowatts each, positioned within defined east and west boundaries on the property. An additional ~10 kilowatt PV array footprint of approximately 1,000 square feet is identified in a designated area where installation is encouraged due to favorable water table conditions. The map also indicates the locations of utility meters, main electrical panels, and approximate utility pathways that require review against as-built documentation. Tree removal is noted as permissible in specified areas to accommodate PV installation.

The site plan identifies critical infrastructure constraints including power lines west of the proposed installation area, natural gas metering and piping running north-south from the road past the Visitor Center, and wettest conditions in the northern field area that may impact placement decisions. The documentation notes that inclusion of the Visitor Center in a second power purchase agreement (PPA) bid is optional, suggesting a phased or flexible approach to the overall solar installation project. As-built plans and detailed site assessments are referenced as necessary review materials prior to final PV array placement and design finalization.

View the file

Other files

File Type Posted
RFP 20_1376 PPA Schedule A - Oden Isolation Building.docx DOCX document
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_10.jpg JPG image
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_08.jpg JPG image
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_01.jpg JPG image
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_03.jpg JPG image
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_02.jpg JPG image
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_07.jpg JPG image
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_05.jpg JPG image
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_12.jpg JPG image
RFP 20_1376 PPA Schedule C - Land Lease Agreement.docx DOCX document
RFP 20_1376 PPA Schedule B - Oden Isolation Building.xlsx XLSX spreadsheet
RFP 20_1376 Isolation Building Oden Visitor Center standard_contract_terms.docx DOCX document
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_04.jpg JPG image
Exhibit 3.Example Utility Bill.Visitor Center.pdf PDF
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_06.jpg JPG image
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_11.jpg JPG image
Exhibit 2.Oden Energy Data.Isolation.VC.xlsx XLSX spreadsheet
RFP 20_1376 PPA Proposal Instructions-Confidential Treatment Form-Vendor Questions Worksheet-Oden Isolation Building.docx DOCX document
Exhibit 4 Visitor Center and Isolation Bldg photos_Page_09.jpg JPG image
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DNR

Polyline

DNR

Callout Yellow boxes are representative of a PV array ~5,000 Sq. Ft and ~50 kW.

Proposed PV arrays should be contained within the far west and far east boundaries of these representative arrays.

DNR

Callout Utility Meter

DNR

Callout Main Electrical Panel

DNR

Polyline

DNR

Arrow

DNR

Polyline

DNR

Callout Approximate utility path. Review as-builts.

DNR

Cloud

0.00

DNR

Callout Approximate area trees can be removed, as needed.

DNR

Polyline

DNR

Callout Yellow area represents approximate footprint for a ~10 kW PV at 1,000 Sq. Ft.

Proposed PV arrays are encouraged in this general area as water table generally rises to the north. Note power lines West of yellow area.

DNR

Callout VC Utility Meter

DNR

Callout VC Main Electrical Panel

DNR

Cloud

DNR

Callout Northern field area is wettest.

DNR

Callout Natural Gas Meter.

Piping believed to run N-S from road past Visitor Center

DNR

Textbox Optional to include Visitor Center in a second PPA bid.