This is an Asbestos Survey: Building Status Report for Building 8401 (Smith Barracks, GE79D Installation) located at Chaffee Road, totaling 51,958 square feet. The three-story concrete structure serves as an AAFES facility with masonry/plastered walls, an unused attic, and no basement.
The survey identifies multiple asbestos-containing materials (ACM) and presumed asbestos-containing materials (PACM) requiring management. ACM identified includes: cement corrugated roof (black, 4,000 M2, rating 30, re-survey 2028); floor tile (tan, 50 M2, rating 65, re-survey 2028); wallboard (plastered white, 1,500 M2, rating 70, re-survey 2026); and floor tiles with mastic (beige/brown, 3,200 M2, rating 70, re-survey 2026). PACM includes roofing material (green, 12 M2, re-survey 2028), safes (3 each, re-survey 2028), and cement roofing panels (gray, 8 M2, re-survey 2028). Numerous non-asbestos materials (NAD) are also documented, including wallboard, vinyl flooring, pipe insulation, fire protection doors, and ceiling tiles requiring no re-survey. The overall building status is ACM with next re-survey recommended in 2026. Two specific homogenous areas (floor tiles plus mastic and wallboard, plastered) are assessed as Priority II, requiring re-assessment within two years. Laboratory results from multiple surveys dating back to 1993 confirm asbestos presence, with chrysotile identified in several samples at concentrations ranging from 2-5 percent.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Installation
GE79D - SMITH BARRACKS
Building Number
Building Utilization
AAFES
ASBESTOS SURVEY: BUILDING STATUS REPORT
This report may not be complete. It is vital to contact the Environmental Division before work activities start.
Dieser Bericht ist nicht komplett. Es ist wichtig die Umweltabteilung zu kontaktieren, bevor Arbeiten beginnen.
DSN: 531-3113 CIV:06111435313113
Identified Materials
RECENT RE-SURVEY INFORMATION
Removed Materials
PREVIOUS ASBESTOS SURVEY INFORMATION
Homogenous
Area ID
ACM
Status
Material description Quantity Rating Re-Survey required
8401-14 ACM Cement corrugated roof, black 4000 M2 30 2028
8401-06 ACM Floor tile, tan (20cm x 20cm) 50 M2 65 2028
8401-04 ACM Wallboard, plastered, white 1500 M2 70 2026
8401-02 ACM Floor tiles plus mastic, beige, brown adhesive (30cm x 30cm) 3200 M2 70 2026
8401-13 PACM Roofing material - other, green 12 M2 27 2028
8401-10 PACM Safe 3 EACH 13 2028
8401-19 PACM Cement roofing panels, gray (20cm x 50cm) 8 M2 27 2028
8401-28 NAD Dust Not required
8401-011 NAD Wallboard, plastered 2800 M2 Not required
8401-018 NAD Floor sheeting vinyl, beige, brown adhesive 7 M2 Not required
8401-020 NAD Floor sheeting vinyl, grey/white, black adhesive 45 M2 Not required
8401-022 NAD Floor sheeting vinyl 10 M2 Not required
8401-023 NAD Floor sheeting vinyl, brown, black adhesive 5 M2 Not required
8401-024 NAD Pipe insulation 140 M Not required
8401-025 NAD Pipe insulation, white 260 M Not required
8401-026 NAD Pipe insulation 130 M Not required
8401-03 NAD Fire protection door(s) 29 EACH Not required
8401-005 NAD Floor tile plus mastic, brown (30 X 30 cm) 2 M2 Not required
8401-27 NAD Dust Not required
8401-29 NAD Dust Not required
8401-30 NAD Pipe insulation Not required
8401-31 NAD Ceiling tiles, white Not required
8401-15 NAD Roofing material - other, black 40 M2 Not required
Building status ACM Recommendation - Next Re-Survey 2026
8401-32 R-ACM Floor tile, beige NA Not required
8401-09 R-ACM Floor tile plus mastic, green (20cm x 20cm) 20 M2 NA Not required
Last Survey Date(s) Surveyed by Risk Score Urgency Level
3/3/1993 Baker Env. 1993 74 II
3/19/2009 CH2MHILL 2009-2010 67 III
11/20/2013 DPW In-house 2014 75 II
1/7/2015 DPW In-house Jan 2015 75 II
11/14/2017 Amec Foster Wheeler 70 II
9/18/2019 DPW inhouse 70 II
4/21/2023 Aecom International Inc. 70 II
Building Description / Inaccessible Areas / Narrative
Three story concrete building (PX), with masonry /plastered walls, unused attic, no basement: areas of buildings: 8401(47309sqft), 8401C (1311sqft) , 8401D, 8401E and 8401F
Bldg. Area
51958
Location
Chaffee road m² ft²
Date of Re-Survey
2/23/2024
Re-Surveyed by
Baker Env. 1993
8401-08 R-ACM Floor tiles, plus mastic, gray/beige, brown adhesive (80cm x 80cm)
30 M2 NA Not required
8401-07 R-ACM Floor tile plus mastic, white (20cm x 20cm) 0 NA Not required
8401-21 R-PACM Gasket material 0 NA Not required
8401-17 R-PACM Freezer 0 NA Not required
8401-12 R-PACM Cement corrugated roof 0 NA Not required
Homogenous Area Description
Floor tiles plus mastic, beige, brown adhesive (30cm x 30cm)
201, 203, 205-207, 214
1st floor: 101-104, 107, 109, 109B, 118, Entry,108, 109A, 113-117, 119-124, 133; 2nd fl poor condition, present in break room
Asbestos Status of HA
ACM
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Recommendation
Estimated Quantity
3200 M2
Abatement Status
PARTLY REMOVED
Condition
POOR
Material Friability
LOW
Material Type
Other
Disturbance Potential
HIGH
HIGH
Activity Level
EASY
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-02
Recent Survey Date
2/21/2024
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
70 II
DPW inhouse9/18/2019 70 II
Amec Foster Wheeler11/14/2017 70 II
Baker Env. 19933/3/1993 65 III
CH2MHILL 2009-20103/19/2009 62 III
DPW In-house 20146/11/2014 50 III
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-002-AQ4 3/3/1993 ACM 4% CHRYSOTILE
8401-002-A14 3/3/1993 ACM 5% CHRYSOTILE
BH-8401-AS-1 4/21/2023 ACM ACM Detected
I - Type of asbestos use
a. Sprayed-on asbestos
b. Asbestos-containing plaster
c. Lightweight asbestos-containing panels
d. Other asbestos-containing products
II
II - Type of asbestos
a. Amphibole asbestos
b. Other asbestos (white)
III - Surface structure of the asbestos product
a. Highly friable fiber structure
b. Non-friable fiber structure without or with insufficient impermeable coating
c. Coated, impermeable surface
IV - Surface conditon of the asbestos product
a. Severe damages
b. Minor damages
c. No damages
V - External impacts of the asbestos product
a. Product is subjected to impacts via direct access (floor level to arm's reach)
b. Product is worked on occasionally
c. Product is subjected to physical impacts
d. Product is subject to vibrations
e. Product is subjected to severe climatic changes
f. Product is located in an area of strong air currents
g. Strong air currents are present in the room in which the asbestos product is located
h. The product may be subject to abrasion
i. Product is not subject to external impacts
VI - Room use
a. Room is used regularly by children, youth, and athletes
b. Room is used constantly or frequently by other persons
c. Room is used occasionally
d. Room is used rarely
VII - Location of the product
a. Directly in the room
b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)
c. Behind a non-airtight suspended ceiling or paneling
d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts
5, 10 or 15
5, 10, 15 or 20
Abatement analysis Priority I
Priority II
Priority III
Sum of the Assessment Points
≥ 80
70-79
≤ 69
Abatement Required Immediately
Re-Assess every <2 Years
Re-Assess every <5 Years
Asbestos presumed or detected in any of the samples?
This material is assessd as Priority:
ACM
2/21/2024Aecom International Inc.
URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM
Building
LOCATION (BUILDING and ROOM NUMBER)
Material located in/at
201, 203, 205-207, 214
Material removed in/at
1st floor: 101-104, 107, 109, 109B, 118, Entry,108, 109A, 113-117, 119-124, 133; 2nd floor: hallA209, 212, 213
HOMOGENOUS AREA IDMATERIAL DESCRIPTION Floor tiles plus mastic, beige, brown adhesive (30cm x 30cm)
8401-02
Items to assess Point values Assessment points
(Signature, Title and Date of survey)
Wallboard, plastered, white
Entire building, all structural walls
Material identified only in room 118
Asbestos Status of HA
ACM
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Recommendation
Estimated Quantity
1500 M2
Abatement Status
NOT ABATED
Condition
POOR
Material Friability
LOW
Material Type
Other
Disturbance Potential
HIGH
LOW
Activity Level
EASY
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-04
Recent Survey Date
2/23/2024
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
70 II
Baker Env. 19933/3/1993 74 II
DPW In-house 20146/11/2014 72 II
DPW inhouse9/18/2019 70 II
Amec Foster Wheeler11/14/2017 70 II
CH2MHILL 2009-20103/19/2009 67 III
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-004-A14 3/3/1993 ACM 2% CHRYSOTILE
8401-04-A 3/19/2009 ACM no Asbestos detected
8401-04-B 3/19/2009 ACM no Asbestos detected
b. Asbestos-containing plaster
c. Lightweight asbestos-containing panels
d. Other asbestos-containing products
II
II - Type of asbestos
a. Amphibole asbestos
b. Other asbestos (white)
III - Surface structure of the asbestos product
a. Highly friable fiber structure
b. Non-friable fiber structure without or with insufficient impermeable coating
c. Coated, impermeable surface
IV - Surface conditon of the asbestos product
a. Severe damages
b. Minor damages
c. No damages
V - External impacts of the asbestos product
a. Product is subjected to impacts via direct access (floor level to arm's reach)
b. Product is worked on occasionally
c. Product is subjected to physical impacts
d. Product is subject to vibrations
e. Product is subjected to severe climatic changes
f. Product is located in an area of strong air currents
g. Strong air currents are present in the room in which the asbestos product is located
h. The product may be subject to abrasion
i. Product is not subject to external impacts
VI - Room use
a. Room is used regularly by children, youth, and athletes
b. Room is used constantly or frequently by other persons
c. Room is used occasionally
d. Room is used rarely
VII - Location of the product
a. Directly in the room
b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)
c. Behind a non-airtight suspended ceiling or paneling
d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts
5, 10 or 15
5, 10, 15 or 20
Abatement analysis Priority I
Priority II
Priority III
Sum of the Assessment Points
≥ 80
70-79
≤ 69
Abatement Required Immediately
Re-Assess every <2 Years
Re-Assess every <5 Years
Asbestos presumed or detected in any of the samples?
This material is assessd as Priority:
(Signature, Title and Date of survey)
ACM
2/23/2024Aecom International Inc.
URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM
Building
LOCATION (BUILDING and ROOM NUMBER)
Material located in/at
Entire building, all structural walls
Material removed in/at
HOMOGENOUS AREA IDMATERIAL DESCRIPTION Wallboard, plastered, white 8401-04
Floor tile, tan (20cm x 20cm)
2nd floor: hall A, hall B
1st floor: 101, 103, 104, 102
Floor tiles beige
Asbestos Status of HA
ACM
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Recommendation
Estimated Quantity
50 M2
Abatement Status
PARTLY REMOVED
Condition
POOR
Material Friability
LOW
Material Type
Other
Disturbance Potential
HIGH
MEDIUM
Activity Level
EASY
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-06
Recent Survey Date
4/21/2023
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
65 III
DPW In-house Jan 20151/7/2015 75 II
DPW In-house 20146/11/2014 67 III
Baker Env. 19933/3/1993 65 III
Amec Foster Wheeler5/14/2017 65 III
CH2MHILL 2009-20103/19/2009 62 III
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-006-A14 3/3/1993 ACM 3% CHRYSOTILE
b. Asbestos-containing plaster
c. Lightweight asbestos-containing panels
d. Other asbestos-containing products
III
II - Type of asbestos
a. Amphibole asbestos
b. Other asbestos (white)
III - Surface structure of the asbestos product
a. Highly friable fiber structure
b. Non-friable fiber structure without or with insufficient impermeable coating
c. Coated, impermeable surface
IV - Surface conditon of the asbestos product
a. Severe damages
b. Minor damages
c. No damages
V - External impacts of the asbestos product
a. Product is subjected to impacts via direct access (floor level to arm's reach)
b. Product is worked on occasionally
c. Product is subjected to physical impacts
d. Product is subject to vibrations
e. Product is subjected to severe climatic changes
f. Product is located in an area of strong air currents
g. Strong air currents are present in the room in which the asbestos product is located
h. The product may be subject to abrasion
i. Product is not subject to external impacts
VI - Room use
a. Room is used regularly by children, youth, and athletes
b. Room is used constantly or frequently by other persons
c. Room is used occasionally
d. Room is used rarely
VII - Location of the product
a. Directly in the room
b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)
c. Behind a non-airtight suspended ceiling or paneling
d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts
5, 10 or 15
5, 10, 15 or 20
Abatement analysis Priority I
Priority II
Priority III
Sum of the Assessment Points
≥ 80
70-79
≤ 69
Abatement Required Immediately
Re-Assess every <2 Years
Re-Assess every <5 Years
Asbestos presumed or detected in any of the samples?
This material is assessd as Priority:
(Signature, Title and Date of survey)
ACM
4/21/2023Aecom International Inc.
URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM
Building
LOCATION (BUILDING and ROOM NUMBER)
Material located in/at
2nd floor: hall A, hall B
Material removed in/at
1st floor: 101, 103, 104, 102
HOMOGENOUS AREA IDMATERIAL DESCRIPTION Floor tile, tan (20cm x 20cm) 8401-06
Cement corrugated roof, black
Roof of main building
Asbestos Status of HA
ACM
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Recommendation
Estimated Quantity
4000 M2
Abatement Status
NOT ABATED
Condition
FAIR
Material Friability
LOW
Material Type
Other
Disturbance Potential
LOW
LOW
Activity Level
DIFFICULT
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-14
Recent Survey Date
4/21/2023
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
30 III
CH2MHILL 2009-20103/19/2009 55 III
DPW In-house 20146/11/2014 35 III
Amec Foster Wheeler11/14/2017 35 III
Baker Env. 19933/3/1993 23 III
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-14-A 3/19/2009 ACM up to 15% Chrysotile-Asbestos detected
8401-14-B 3/19/2009 ACM up to 15% Chrysotile-Asbestos detected
b. Asbestos-containing plaster
c. Lightweight asbestos-containing panels
d. Other asbestos-containing products
III
II - Type of asbestos
a. Amphibole asbestos
b. Other asbestos (white)
III - Surface structure of the asbestos product
a. Highly friable fiber structure
b. Non-friable fiber structure without or with insufficient impermeable coating
c. Coated, impermeable surface
IV - Surface conditon of the asbestos product
a. Severe damages
b. Minor damages
c. No damages
V - External impacts of the asbestos product
a. Product is subjected to impacts via direct access (floor level to arm's reach)
b. Product is worked on occasionally
c. Product is subjected to physical impacts
d. Product is subject to vibrations
e. Product is subjected to severe climatic changes
f. Product is located in an area of strong air currents
g. Strong air currents are present in the room in which the asbestos product is located
h. The product may be subject to abrasion
i. Product is not subject to external impacts
VI - Room use
a. Room is used regularly by children, youth, and athletes
b. Room is used constantly or frequently by other persons
c. Room is used occasionally
d. Room is used rarely
VII - Location of the product
a. Directly in the room
b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)
c. Behind a non-airtight suspended ceiling or paneling
d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts
5, 10 or 15
5, 10, 15 or 20
Abatement analysis Priority I
Priority II
Priority III
Sum of the Assessment Points
≥ 80
70-79
≤ 69
Abatement Required Immediately
Re-Assess every <2 Years
Re-Assess every <5 Years
Asbestos presumed or detected in any of the samples?
This material is assessd as Priority:
(Signature, Title and Date of survey)
ACM
4/21/2023Aecom International Inc.
URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM
Building
LOCATION (BUILDING and ROOM NUMBER)
Material located in/at
Roof of main building
Material removed in/at
HOMOGENOUS AREA IDMATERIAL DESCRIPTION Cement corrugated roof, black 8401-14
Roofing material - other, green
Roof above 105,HD-S 1+2,3A,4
Asbestos Status of HA
PACM
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Recommendation
Estimated Quantity
12 M2
Abatement Status
NOT ABATED
Condition
GOOD
Material Friability
LOW
Material Type
Other
Disturbance Potential
LOW
LOW
Activity Level
DIFFICULT
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-13
Recent Survey Date
4/21/2023
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
27 III
CH2MHILL 2009-20103/19/2009 30 III
Amec Foster Wheeler11/14/2017 27 III
DPW In-house 20146/11/2014 24 III
Baker Env. 19933/3/1993 23 III
b. Asbestos-containing plaster
c. Lightweight asbestos-containing panels
d. Other asbestos-containing products
III
II - Type of asbestos
a. Amphibole asbestos
b. Other asbestos (white)
III - Surface structure of the asbestos product
a. Highly friable fiber structure
b. Non-friable fiber structure without or with insufficient impermeable coating
c. Coated, impermeable surface
IV - Surface conditon of the asbestos product
a. Severe damages
b. Minor damages
c. No damages
V - External impacts of the asbestos product
a. Product is subjected to impacts via direct access (floor level to arm's reach)
b. Product is worked on occasionally
c. Product is subjected to physical impacts
d. Product is subject to vibrations
e. Product is subjected to severe climatic changes
f. Product is located in an area of strong air currents
g. Strong air currents are present in the room in which the asbestos product is located
h. The product may be subject to abrasion
i. Product is not subject to external impacts
VI - Room use
a. Room is used regularly by children, youth, and athletes
b. Room is used constantly or frequently by other persons
c. Room is used occasionally
d. Room is used rarely
VII - Location of the product
a. Directly in the room
b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)
c. Behind a non-airtight suspended ceiling or paneling
d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts
5, 10 or 15
5, 10, 15 or 20
Abatement analysis Priority I
Priority II
Priority III
Sum of the Assessment Points
≥ 80
70-79
≤ 69
Abatement Required Immediately
Re-Assess every <2 Years
Re-Assess every <5 Years
Asbestos presumed or detected in any of the samples?
This material is assessd as Priority:
(Signature, Title and Date of survey)
PACM
4/21/2023Aecom International Inc.
URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM
Building
LOCATION (BUILDING and ROOM NUMBER)
Material located in/at
Roof above 105,HD-S 1+2,3A,4
Material removed in/at
HOMOGENOUS AREA IDMATERIAL DESCRIPTION Roofing material - other, green 8401-13
Cement roofing panels, gray (20cm x 50cm)
Roof chimney panels
Asbestos Status of HA
PACM
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Recommendation
Estimated Quantity
8 M2
Abatement Status
NOT ABATED
Condition
FAIR
Material Friability
LOW
Material Type
Other
Disturbance Potential
LOW
LOW
Activity Level
DIFFICULT
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-19
Recent Survey Date
4/21/2023
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
27 III
CH2MHILL 2009-20103/19/2009 30 III
DPW In-house 20146/11/2014 27 III
Amec Foster Wheeler11/14/2017 27 III
Baker Env. 19933/3/1993 23 III
b. Asbestos-containing plaster
c. Lightweight asbestos-containing panels
d. Other asbestos-containing products
III
II - Type of asbestos
a. Amphibole asbestos
b. Other asbestos (white)
III - Surface structure of the asbestos product
a. Highly friable fiber structure
b. Non-friable fiber structure without or with insufficient impermeable coating
c. Coated, impermeable surface
IV - Surface conditon of the asbestos product
a. Severe damages
b. Minor damages
c. No damages
V - External impacts of the asbestos product
a. Product is subjected to impacts via direct access (floor level to arm's reach)
b. Product is worked on occasionally
c. Product is subjected to physical impacts
d. Product is subject to vibrations
e. Product is subjected to severe climatic changes
f. Product is located in an area of strong air currents
g. Strong air currents are present in the room in which the asbestos product is located
h. The product may be subject to abrasion
i. Product is not subject to external impacts
VI - Room use
a. Room is used regularly by children, youth, and athletes
b. Room is used constantly or frequently by other persons
c. Room is used occasionally
d. Room is used rarely
VII - Location of the product
a. Directly in the room
b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)
c. Behind a non-airtight suspended ceiling or paneling
d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts
5, 10 or 15
5, 10, 15 or 20
Abatement analysis Priority I
Priority II
Priority III
Sum of the Assessment Points
≥ 80
70-79
≤ 69
Abatement Required Immediately
Re-Assess every <2 Years
Re-Assess every <5 Years
Asbestos presumed or detected in any of the samples?
This material is assessd as Priority:
(Signature, Title and Date of survey)
PACM
4/21/2023Aecom International Inc.
URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM
Building
LOCATION (BUILDING and ROOM NUMBER)
Material located in/at
Roof
Material removed in/at
HOMOGENOUS AREA IDMATERIAL DESCRIPTION Cement roofing panels, gray (20cm x 50cm) 8401-19
Safe
2nd floor: 215
102, 126, 209, 109, 125A, interior insulation, metal enclosed
Asbestos Status of HA
PACM
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Recommendation
Estimated Quantity
3 EACH
Abatement Status
PARTLY REMOVED
Condition
FAIR
Material Friability
Material Type
TSI-Other
Disturbance Potential
LOW
MEDIUM
Activity Level
DIFFICULT
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-10
Recent Survey Date
4/21/2023
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
13 III
CH2MHILL 2009-20103/19/2009 60 III
Baker Env. 19933/3/1993 25 III
DPW In-house 20146/11/2014 13 III
Amec Foster Wheeler11/14/2017 13 III
b. Asbestos-containing plaster
c. Lightweight asbestos-containing panels
d. Other asbestos-containing products
III
II - Type of asbestos
a. Amphibole asbestos
b. Other asbestos (white)
III - Surface structure of the asbestos product
a. Highly friable fiber structure
b. Non-friable fiber structure without or with insufficient impermeable coating
c. Coated, impermeable surface
IV - Surface conditon of the asbestos product
a. Severe damages
b. Minor damages
c. No damages
V - External impacts of the asbestos product
a. Product is subjected to impacts via direct access (floor level to arm's reach)
b. Product is worked on occasionally
c. Product is subjected to physical impacts
d. Product is subject to vibrations
e. Product is subjected to severe climatic changes
f. Product is located in an area of strong air currents
g. Strong air currents are present in the room in which the asbestos product is located
h. The product may be subject to abrasion
i. Product is not subject to external impacts
VI - Room use
a. Room is used regularly by children, youth, and athletes
b. Room is used constantly or frequently by other persons
c. Room is used occasionally
d. Room is used rarely
VII - Location of the product
a. Directly in the room
b. In the ventilation for the room (in lining or outher wrapping of non-airtight ducts)
c. Behind a non-airtight suspended ceiling or paneling
d. Behind an airtight suspended ceiling or paneling, outside air-tight went ducts
5, 10 or 15
5, 10, 15 or 20
Abatement analysis Priority I
Priority II
Priority III
Sum of the Assessment Points
≥ 80
70-79
≤ 69
Abatement Required Immediately
Re-Assess every <2 Years
Re-Assess every <5 Years
Asbestos presumed or detected in any of the samples?
This material is assessd as Priority:
(Signature, Title and Date of survey)
PACM
4/21/2023Aecom International Inc.
URGENCY OF ASBESTOS ABATEMENT - ASSESSMENT FORM
Building
LOCATION (BUILDING and ROOM NUMBER)
Material located in/at
2nd floor: 215
Material removed in/at
102, 126, 209, 109, 125A, HOMOGENOUS AREA IDMATERIAL DESCRIPTION Safe 8401-10
Fire protection door(s)
1st and 2nd floor: all doors but office doors
Although the samples of the fire doors have been analyzed to be NAD, it cannot be excluded that another fire door may contain asbestos. Therefore O&M is still recommended.
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
O&M
Recommendation
Estimated Quantity
29 EACH
Abatement Status
NOT ABATED
Condition
FAIR
Material Friability
HIGH
Material Type
TSI-Other
Disturbance Potential
HIGH
HIGH
Activity Level
MEDIUM
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-03
Recent Survey Date
3/19/2009
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Baker Env. 19933/3/1993 30 III
Sample ID Sampling
Date
Asbestos detected
8401-03-A 3/19/2009 NAD no Asbestos detected
Roofing material - other, black
Roof above 106, east end, VD-S 1-1,1-2,2,3
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
None
Recommendation
Estimated Quantity
40 M2
Abatement Status
NOT ABATED
Condition
FAIR
Material Friability
LOW
Material Type
Other
Disturbance Potential
LOW
LOW
Activity Level
DIFFICULT
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-15
Recent Survey Date
3/19/2009
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Baker Env. 19933/3/1993 23 III
Sample ID Sampling
Date
Asbestos detected
8401-15-A 3/19/2009 NAD no Asbestos detected
Floor tile plus mastic, brown (30 X 30 cm)
1ST, PX, ROOM 101, 109
USED AS REPLACEMENT IN ROOM 101, 109
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
O&M
Recommendation
Estimated Quantity
2 M2
Abatement Status
Condition
Material Friability
NONFRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-005
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-005-A14 3/3/1993 NAD No Asbestos Detected
8401-005-B14 3/3/1993 NAD No Asbestos Detected
Wallboard, plastered
1ST, PX, ENTIRE BUILDING, ALL NONSTRUCTURAL WALLS AND STRUCTURAL
OF ROOM 113
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
O&M
Recommendation
Estimated Quantity
2800 M2
Abatement Status
Condition
Material Friability
NONFRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-011
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-011-A14 3/3/1993 NAD No Asbestos Detected
8401-011-B14 3/3/1993 NAD No Asbestos Detected
Floor sheeting vinyl, beige, brown adhesive
1ST, VENDING AREA, ROOM 134
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
O&M
Recommendation
Estimated Quantity
7 M2
Abatement Status
Condition
Material Friability
NONFRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-018
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-018-A14 3/3/1993 NAD No Asbestos Detected
8401-018-B14 3/3/1993 NAD No Asbestos Detected
Floor sheeting vinyl, grey/white, black adhesive
2ND, OFFICES, ROOMS 202, 204
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
O&M
Recommendation
Estimated Quantity
45 M2
Abatement Status
Condition
Material Friability
NONFRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-020
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-020-A14 3/3/1993 NAD No Asbestos Detected
8401-020-B14 3/3/1993 NAD No Asbestos Detected
Floor sheeting vinyl
3RD, OFFICE, 301
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
O&M
Recommendation
Estimated Quantity
10 M2
Abatement Status
Condition
Material Friability
NONFRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-022
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-022-A14 3/3/1993 NAD No Asbestos Detected
8401-022-B14 3/3/1993 NAD No Asbestos Detected
Floor sheeting vinyl, brown, black adhesive
3RD, OFFICE, ROOM 301
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
O&M
Recommendation
Estimated Quantity
5 M2
Abatement Status
Condition
Material Friability
NONFRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-023
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-023-A14 3/3/1993 NAD No Asbestos Detected
8401-023-B14 3/3/1993 NAD No Asbestos Detected
Pipe insulation
ATTIC, 1ST, ATTIC, ATTIC AREA, 1ST, 2ND, 3RD
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
REPLACE
Recommendation
Estimated Quantity
140 M
Abatement Status
Condition
Material Friability
FRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-024
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-024-A14 3/3/1993 NAD No Asbestos Detected
8401-024-B14 3/3/1993 NAD No Asbestos Detected
8401-024-C14 3/3/1993 NAD No Asbestos Detected
Pipe insulation, white
1ST, WAREHOUSE/HEATING, HEATING, MECHANICAL HALL, HALL 107, 106
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
REPLACE
Recommendation
Estimated Quantity
260 M
Abatement Status
Condition
Material Friability
FRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-025
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-025-A14 3/3/1993 NAD No Asbestos Detected
8401-025-B14 3/3/1993 NAD No Asbestos Detected
8401-025-C14 3/3/1993 NAD No Asbestos Detected
2ND, PX, AIR HANDLING, ABOVE ROOM 113
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
O&M
Recommendation
Estimated Quantity
130 M
Abatement Status
Condition
Material Friability
NONFRIABLE
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-026
Recent Survey Date
3/3/1993
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
Laboratory Results in %
8401-026-A14 3/3/1993 NAD No Asbestos Detected
8401-026-B14 3/3/1993 NAD No Asbestos Detected
8401-026-C14 3/3/1993 NAD No Asbestos Detected
Dust
Dust on stairs in storage
Dust on stair string
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
Recommendation
Estimated Quantity
Abatement Status
Condition
Material Friability
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-27
Recent Survey Date
11/20/2013
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
8401-27 11/20/2013 NAD No asbestos detected
Dust on pipes in storage
Dust on heating pipe in storage area
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
Material Friability
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-28
Recent Survey Date
11/20/2013
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
8401-28 11/20/2013 NAD No asbestos detected
Floor next to stairs
Dust on floor next to stairs
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
Material Friability
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-29
Recent Survey Date
11/20/2013
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
8401-29 11/20/2013 NAD No asbestos detected
Above entrance to storage area
Fibres and cement tested
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
Material Friability
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-30
Recent Survey Date
11/20/2013
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
8401-30 11/20/2013 NAD No asbestos detected
Ceiling tiles, white
Storage area, second floor
Asbestos Status of HA
NAD
RECENT HA SURVEY INFORMATION
Comments
Homogenous Area Location present:
removed:
Re-Survey required
Not required
Material Friability
Material Type
Disturbance Potential
Activity Level
Accessibility
ASBESTOS SURVEY: HOMOGENOUS AREA (HA) DESCRIPTION and ASSESSMENT
Installation
GE79D - SMITH BARRACKS
Building Number
Homogenous Area
8401-31
Recent Survey Date
11/20/2013
Last Surveyed Surveyed by Previous Risk Score Previous Urgency Level
PREVIOUS HA SURVEY INFORMATION
Laboratory Results
Risk Score / Urgency Level
Sample ID Sampling
Date
Asbestos detected
8401-31 11/20/2013 NAD No asbestos detected
File details come from the government source that posted it. Updated .