Event_4391_-_Drawings.pdf
PDF 2 MB Posted
- Attached to
- BID-MCC - Parking Facility Repairs
- Solicitation number
- 0000004391
- Issued by
- Hennepin County, Minnesota
About this file
This is an architectural drawing set prepared by Walker Consultants for the Convention Center Parking Facility Repairs project located at 1403 3rd Avenue South, Minneapolis, Minnesota 55404. The project, identified as Project No. 21-005657.00, involves selective demolition and repair of structural building elements across six parking levels, including concrete floor repairs, overhead repairs, traffic topping applications, expansion joint restoration, and miscellaneous repairs to columns, beams, walls, and mechanical systems. The drawing set includes a cover sheet, general notes and legends with work item schedules, level plans for all six floors, and detailed repair specifications. The facility must remain operational during construction with phasing constraints requiring maintenance of minimum pedestrian access widths of 6 feet and headroom of 7 feet, temporary vehicular one-way travel lanes of minimum 12 feet, and coordinated parking space closures that do not exceed specified limits at any given time. The drawings are marked as preliminary and dated July 22, 2027, for owners' review.
The construction documents shall be performed in accordance with all applicable federal, state of Minnesota, and City of Minneapolis codes and ordinances, including fire codes. All work must be field-verified prior to fabrication and construction, with the contractor responsible for determining actual extent and locations of repair areas as specified in the construction specifications section. Critical safety considerations include post-tensioning tendons embedded near both surfaces of floor slabs that may break with explosive force if cut, requiring contractor precautions and verification prior to any cutting or anchor installation. The contractor must submit a construction and shoring program two weeks prior to work commencement, provide all temporary shoring and bracing, and submit stamped calculations and plans prepared by a Minnesota-licensed professional engineer. Concrete specifications require 5000 PSI compressive strength at 28 days, a maximum water-cement ratio of 0.40, and epoxy coating of all reinforcement except welded wire reinforcement. All existing services and utilities must be maintained during repair work, with temporary connections requiring owner approval prior to commencement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Event_4391_-_Pre-Bid_Meeting_Information.pdf | ||
| Responsible_Contractor_Forms.pdf | ||
| Event_4391_-_Specification.pdf | ||
| Event_4391_-_Call_for_Bids.pdf | ||
| Event_4391_-_Bid_Form.xlsx | XLSX spreadsheet | |
| BID-MCC_-_Parking_Facility_Repairs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR BY ANY MEANS WITHOUT PERMISSION FROM WALKER CONSULTANTS.
ENGINEER
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
PARKING FACILITY REPAIRS
JULY 22, 2027
OWNERS REVIEW
PROJECT NO: 21-005657.00
DRAWING INDEX
NO: SHEET NAME
RESTORATION
R-000 COVER SHEET AND SITE LOCATION MAP
R-001 GENERAL NOTES, LEGENDS, & WORK ITEM SCHEDULE
R-101 LEVEL 1 PLAN
R-102 LEVEL 2 PLAN
R-103 LEVEL 3 PLAN
R-104 LEVEL 4 PLAN
R-105 LEVEL 5 PLAN
R-106 LEVEL 6 PLAN
R-501 REPAIR DETAILS
R-502 REPAIR DETAILS
R-503 REPAIR DETAILS
PROJECT
SITE
IMAGE: GOOGLE MAPS
IMAGE: GOOGLE MAPS
LEVEL 3
LEVEL 4
LEVEL 5
LEVEL 2
LEVEL 1
LEVEL 6
ISOMETRIC
GENERAL RESTORATION NOTES
A. CONSTRUCTION
1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, OF
MINNESOTA, AND CITY OF MINNEAPOLIS CODES AND ORDINANCES, INCLUDING FIRE CODES.
2. ALL MATERIAL PROPERTIES SHALL BE AS NOTED IN SPECIFICATIONS.
3. PRIOR TO FABRICATION OF ANY MATERIAL OR PLACEMENT OF CONCRETE, FIELD VERIFY ALL
EXISTING DIMENSIONS AND CONDITIONS AS SHOWN ON DRAWINGS. REPORT ALL
4. DO NOT SCALE DRAWINGS
B. CONSTRUCTION DOCUMENTS
1. CONSTRUCTION DOCUMENTS ENTITLED "CONVENTION CENTER PARKING FACILITY REPAIRS 2026"
INCLUDES THESE DRAWINGS AND SEPARATELY BOUND SPECIFICATIONS. FOR PURPOSE OF
PERFORMING THE WORK, DRAWINGS AND SPECIFICATIONS SHALL BE A SINGLE UNIT.
2. DIMENSIONS SHOWN ON PLANS ARE BASED ON ORIGINAL CONSTRUCTION DOCUMENTS. THE
CONTRACTOR IS REQUIRED TO FIELD VERIFY ALL CONDITIONS FOR THE PURPOSES OF
PREPARING THE BID IN PERFORMING THE WORK.
3. REFER TO SPECIFICATION SECTION 020010 FOR SCOPE, DESCRIPTION, AND REQUIREMENTS OF
THE WORK.
C. DETAILS AND SYMBOLS
1. ALL CONCRETE REPAIR DETAILS ARE SHOWN ON DRAWING SERIES R-500.
2. DETAILS LABELED "FOR ALL CLARIFICATION ONLY" DO NOT REPRESENT A SEPARATE PRICE ITEM.
THESE DETAILS SUPPLEMENT THE BASIC DETAIL TO PROVIDE ADDITIONAL INFORMATION IN SOME
CASES THESE DETAILS SHOW VARIATIONS OF THE TYPICAL CONDITION.
3. WHEN THE WORK ITEM BUBBLE IS NOTED (TYP), IT MEANS THE WORK ITEM OCCURS AT ALL
LOCATIONS WITH THE APPLICABLE DETERIORATION OR DESIGNATION SYMBOL OCCURS ON A
PLAN.
4. WHERE (TAR) IS NOTED, IT MEANS THERE MAY BE AREAS OF THIS WORK IN ADDITION TO THE
PARTICULAR DESIGNATED AREAS
5. WHERE TWO OR MORE WORK ITEM BUBBLES ARE SHOWN GROUPED TOGETHER, IT MEANS ANY
OR ALL OF THE DESIGNATED WORK SHOWN MAY APPLICABLE. COORDINATION OF WORK ITEMS IS
THE CONTRACTOR'S RESPONSIBILITY.
6. WHEN WORK ITEM DETAILS ARE LISTED AS INCIDENTAL, THIS WORK IS INCLUDED IN THE
PAYMENT OF THE OTHER WORK ITEM AND DOES NOT HAVE A SEPARATE PRICE.
7. WHEN THE DETAIL IS LABELED FOR REFERENCE ONLY IT PROVIDES INFORMATION ABOUT
INCIDENTAL WORK AND DOES NOT HAVE A PAY UNIT.
8. CONTRACTOR IS RESPONSIBLE FOR DETERMINING ACTUAL EXTENT AND LOCATIONS OF REPAIR
AREAS IN ACCORDANCE WITH THE SPECIFICATIONS: WORK ITEMS ARE SHOWN ONLY TO
REPRESENT THE TYPES OF DETERIORATION.
9. SEE WORK ITEM SPECIFICATION FOR INFORMATION REGARDING DETAILS.
D. CONCRETE PROTECTION FOR REINFORCEMENT
1. THE FOLLOWING APPLIES FOR FULL SECTION CONCRETE REPLACEMENT OR PARTIAL DEPTH
REPAIRS AS SHOWN ON THE DRAWINGS.
2. THE MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE PER ACI 318-14, SECTION
7.7
3. MINIMUM COVER FOR REINFORCING IN NON-PRESTRESSED CONCRETE AND NON-POST TENSION
MEMBERS.
CONCRETE COVER
(INCHES)
a. SLAB TOP REINFORCEMENT 1 1/2
b. SLAB BOTTOM REINFORCEMENT 3/4
c. BEAM TOP REINFORCEMENT, U.N. 3
d. BEAM SIDE AND BOTTOM (#5 OR SMALLER) 1 1/2
e. BEAM SIDE AND BOTTOM (#6 OR GREATER) 2 1/2
f. COLUMN TIES 1 1/2
*OR 3X BAR DIAMETER, WHICHEVER IS GREATER.
E. EPOXY COATING FOR REINFORCEMENT AND ANCHORS.
1. EPOXY COAT ALL REINFORCEMENT, EXCEPT WELDED WIRE REINFORCEMENT, IN CAST IN PLACE
CONCRETE.
F. SHORING AND BRACING
1. THE SCOPE OF THIS PROJECT INVOLVES SELECTIVE DEMOLITION AND REPAIR OF STRUCTURAL
BUILDING ELEMENTS THAT WILL REQUIRE TEMPORARY SHORING OF EXISTING AND NEW
CONSTRUCTION TO REMAIN. CONTRACTOR SHALL GENERATE A CONSTRUCTION/SHORING
PROGRAM AND SUBMIT TO ENGINEER FOR RECORD TWO (2) WEEKS PRIOR TO THE
COMMENCEMENT OF WORK.
2. CONTRACTOR SHALL PROVIDE ALL SHORING, BRACING, SHEETING, ETC. REQUIRED FOR SAFETY
AND PROPER EXECUTION OF THE WORK.
3. CONTRACTOR IS SOLELY RESPONSIBLE TO PREPARE SHOP DRAWINGS FOR BRACING ENSURING
MEMBERS DESIGNED AND STAMPED/SEALED BY A REGISTERED PROFESSIONAL ENGINEER
(REGISTERED IN THE STATE OF MINNESOTA) AND SUBMIT THEM TO THE ENGINEER FOR RECORD.
4. THE CONTRACTOR SHALL PROVIDE STAMPED/SIGNED CALCULATIONS, PLANS AND DETAILS FOR
THE TEMPORARY SUPPORT OF NEW AND EXISTING CONSTRUCTION TO REMAIN PREPARED BY AN
ENGINEER LICENSED TO PRACTICE IN THE STATE OF MINNESOTA.
G. EXISTING SERVICES AND UTILITIES
1. CONTRACTOR SHALL REVIEW ALL EXISTING CONDITIONS TO DETERMINE ALL ELECTRICAL AND
MECHANICAL SERVICES AND UTILITIES AFFECTED BY THE REPAIR WORK. MAKE ALL NECESSARY
TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SERVICES TO ALL AREAS OF THE BUILDING
OR OTHER AREAS (NOT IN CONTRACT) AFFECTED BY WORK. THE CONTRACTOR SHALL SUBMIT
THE METHODS AND SCHEDULE TEMPORARY CONNECTIONS FOR THE OWNER'S APPROVAL PRIOR
TO COMMENCEMENT.
H. CAST-IN-PLACE CONCRETE.
1. CONCRETE REINFORCEMENT REQUIREMENTS SEE SECTION 020010 FOR SPECIFIC USES
2. CAST IN PLACE CONVENTIONAL CONCRETE
a. COMPRESSIVE STRENGTH 5000 PSI AT 28 DAYS (2500 @ 3 DAYS)
b. WATER-CEMENT RATIO 0.40 MAX
c. MAX SIZE AGGREGATE 1/2 INCH (SELECT LARGER AGG FOR
SECTION GREATER THAN 1/2 INCH)
d. SLUMP (MAXIMUM) 6" WITH SUPER PLASTICIZER
(AFTER WATER REDUCER ADDITION)
e. AIR CONTENT 7% ± 1 1/2%
f. CEMETITIOUS
MATERIAL CONTENT 658 LB/CY MIN*
MAXIMUM PERMISSIBLE CEMENTITIOUS CONTENT
a. FLY ASH: (TYPE F ONLY) 25%
b. SLAG: 50%
c. FLY ASH & SLAG: 50%
3. ALL CONCRETE SPATTER CREATED DURING CONSTRUCTION AND CONSTRUCTION DEBRIS SHALL
BE REMOVED FROM ALL EXISTING COMPONENTS.
4. ANY PAINTED / STAINED ELEMENTS DAMAGED BY ANY CONSTRUCTION ACTIVITIES SHALL BE
RESTORED / PAINTED / STAINED TO MATCH PRE-CONSTRUCTION CONDITION.
5. FLY ASH TYPE F ONLY.
I. ABBREVIATIONS
1. APPROX = APPROXIMATELY
2. AGG = AGGREGATE
3. BM = BEAM
4. BOT = BOTTOM
5. CIP = CAST IN PLACE
6. CJ = CONSTRUCTION JOINT/CONTROL JOINT
7. CLR = CLEARANCE
8. COL = COLUMN
9. CONC = CONCRETE
10. DET = DETAIL
11. EA = EACH
12. EE = EACH END
13. ES = EACH SIDE
14. EMBED = EMBEDMENT LENGTH
15. EJ = EXPANSION JOINT
16. EXIST = EXISTING
17. FIN = FINISHED
18. FL = FLOOR
19. HORIZ = HORIZONTAL
20. IN = INCHES
21. INC = INCIDENTAL
22. LF = LINEAR FOOT
23. LS = LUMP SUM
24. MAX = MAXIMUM
25. MIN = MINIMUM
26. N/A = NOT APPLICABLE
27. OC = ON CENTER
28. OCA = ON CEILING ABOVE
29. OH = OPPOSITE HAND
30. P/C = PRECAST
31. P-T = POST-TENSIONING
32. REINF = REINFORCEMENT
33. REQ'D = REQUIRED
34. SF = SQUARE FOOT
35. SIM = SIMILAR
36. SOG = SLAB ON GROUND
37. SPEC = SPECIFICATION
38. SUPT = SUPPORTED
39. TAR = TYPICAL AS REQUIRED
40. TYP = TYPICAL
41. UN OR UNO = UNLESS NOTED OTHERWISE
42. VERT = VERTICAL
43. VIF = VERIFY IN FIELD
44. WI = WORK ITEM
45. WWR = WELDED WIRE REINFORCEMENT
J. ELECTRICAL CAUTIONARY NOTES
1. UNKNOWN IF SLAB CONTAINS EMBEDDED ELECTRICAL CONDUIT. CONTRACTOR SHALL TAKE ALL
PRECAUTIONS NECESSARY TO AVOID CUTTING/DAMAGING CONDUIT. IF CONDUIT IS DAMAGE AS
RESULT OF CONSTRUCTION OPERATIONS NOTIFY OWNER AND ENGINEER IMMEDIATELY. CONDUIT
DAMAGE BY CONSTRUCTION OPERATION SHALL BE REPAIRED BY CONTRACTOR AT NO COST TO
OWNER. DAMAGED CONDUIT THAT IS NOT A RESULT OF CONSTRUCTION OPERATIONS SHALL BE
REPAIRED/REPLACED PER ELECTRICAL ALLOWANCE.
K. PHASING
a. PHASING SHALL BE AS SCHEDULED BY THE CONTRACTOR AND APPROVED BY THE
ENGINEER/OWNER.
b. GARAGE SHALL REMAIN OPERATION ALL TIMES. FOR PARKING SPACE CLOSURE LIMITS SEE
SPECIFICATION SECTION "SUMMARY OF WORK FOR RESTORATION."
c. WHILE THE GARAGE IS OPERATING FOR CONCRETE REPAIRS AND TRAFFIC TOPPING INSTALLATION
THE ACTUAL NUMBER OF SPACES TAKEN OUT OF SERVICE AT ANY ONE TIME WILL VARY
DEPENDING UPON THE TIME OF YEAR. THE NUMBER OF SPACES WILL BE COORDINATED WITH THE
OWNER/GARAGE OPERATOR.
d. THE CONTRACTOR SHALL PROVIDE UNOBSTRUCTED PEDESTRIAN ACCESS (PROTECTED WHEN
NECESSARY) TO ALL EMERGENCY EGRESS STAIRS AT ALL TIMES. THE CONTRACTOR SHALL
INSTALL AND MAINTAIN SIGNAGE THAT CLEARLY DIRECTS PATRONS TO AND FROM THESE
DESTINATIONS. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN LIGHTING FOR THESE PATHS IN
THE EVENT THE GARAGE LIGHTING IS BLOCKED OR REDUCED BY PROJECT RELATED WORK.
e. IT SHALL BE THE OWNER OR HIS AGENT'S RESPONSIBILITY TO CLEAR WORK PHASE AREA OF VEHICLES. THE CONTRACTOR SHALL WORK IN UNISON WITH THE CLEARING OPERATION TO CAPTURE
THE AREAS BY INCREMENTALLY INSTALLING BARRICADES TO PREVENT VEHICLES FROM
REENTERING THE AREA AS IT IS CLEARED. IN ADDITION TEMPORARY SIGNAGE SHALL BE
INSTALLED AND ADJUSTED BY THE CONTRACTOR DURING THE WORK/PROTECTION ZONE CAPTURE
EFFORT. NOTE THAT NEW AREAS CANNOT BE CAPTURED PRIOR TO WORK ZONES OR PORTIONS
THEREOF BEING RETURNED TO SERVICE SO THAT THE MAXIMUM NUMBER OF SPACES OUT OF
SERVICE SHALL NOT BE EXCEEDED. ALLOW 24 HOURS BETWEEN THE TURNING SPACES TO SERVICE
AN OCCUPYING EQUAL NUMBER OF SPACES FOR THE NEXT PHASE OF WORK.
f. BARRICADES SHALL BE OF SUFFICIENT CONSTRUCTION TO PREVENT INADVERTENT ACCESS BY PATRON VEHICLES AND PEDESTRIANS. THE BARRICADES CAN BE INCORPORATED INTO THE WORK
ZONE PROTECTION THAT ARE INTENDED TO PREVENT THE ESCAPE OF DUST AND OTHER DEBRIS
FROM THE WORK ZONE.
g. THE FOLLOWING PARAMETERS SHALL BE CONSIDERED WHEN DEVELOPING PHASING PLANS.
PEDESTRIAN PATH WIDTH(MINIMUM): 6'-0"
PEDESTRIAN PATH HEADROOM(MINIMUM): 7'-0"
TEMPORARY VEHICLE ONE-WAY TRAVEL(MINIMUM): 12'-0"
TEMPORARY VEHICLE HEAD ROOM HEIGHT: AS POSTED AT
GARAGE ENTRANCE
h. CONTRACTOR SHALL BE RESPONSIBLE TO LOCKOUT STAIR ACCESS INTO WORK, WORK PHASE, AND
AREAS UNDER CONSTRUCTION TO PREVENT UNAUTHORIZED PATRON ACCESS. DOOR SHALL BE
SEALED OFF TO PREVENT AIRBORNE DUST FROM ENTERING INTO STAIRWAYS AND ELEVATOR
SHAFTS.
3. MISCELLANEOUS NOTES
a. OWNER AND THE ENGINEER RESERVE THE RIGHT TO ISSUE A STOP WORK ORDER FOR SPECIFIC AREAS/WORK ITEMS IF IN THE OPINION OF EITHER ONGOING WORK DOES NOT MEET THE PHASING
PARAMETERS OF THE PROJECT OR PRESENT HAZARDS TO THE PATRONS OF THE GARAGE.
CONTRACTOR SHALL NOT BE ENTITLED TO ADDITIONAL COMPENSATION.
b. THE PHASING CONCEPTS CONTAINED IN THESE DOCUMENTS ARE INTENDED TO INDICATE
REASONABLE SCENARIOS FOR PHASING THE WORK. NOT ALL INFORMATION REQUIRED FOR
CONTRACTOR PHASING SUBMITTALS ARE INCLUDED IN THESE CONCEPTS AND THEY DO NOT I
NCLUDE ALL CHALLENGES THAT WILL BE PRESENT IN PERFORMING THIS PROJECT IN A PHASED
MANNER.
c. WORK ZONES SHALL NOT BE RETURNED TO SERVICE IF HAZARDOUS CONDITIONS ARE PRESENT.
d. DO NOT RETURN AREAS TO SERVICE UNLESS EXISTING STRIPING AFFECTED BY WORK HAS BEEN
RESTORED OR NEW STRIPING HAS BEEN APPLIED.
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
License No 5091 Date: 07/22/2026
Patrick J. Lewis, PE
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
PJL
JMK
21-005657.00
GENERAL NOTES,
LEGENDS, & WORK ITEM
SCHEDULE
R-001
07/22/2027
OWNERS REVIEW
WORK ITEM LEGEND:
NOTES:
1. NOT ALL WORK ITEMS HAVE DETAILS.
2. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
X.X.X
WORK ITEM NO
XXX
WORK ITEM NOTE
(SEE ABBREVIATIONS)
CLARIFICATION
DETAIL NO
WORK ITEM LIST
REVISIONS
MARK DATE DESCRIPTION
D N
U P
FD FD
FDFD
1 2
A
B
B.4
C
3 4 6 7 8 10 11 12 13 13.5 145
301'-2"
23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"
3.11
25.3
3.11
TYP
3.11
3.11
3.11
3.11
6.7
SLAB
7.1
3.11
7.1
11.3 6.7
COL
45.4
7.1
6.7
COL
6.7
COL 6.1
25.3
3.11
30.1
ELEC BOX
30.1
ELEC BOX 3.11
30.1
ELEC BOX
LEVEL 3
LEVEL 4
LEVEL 5
LEVEL 2
LEVEL 1
LEVEL 6
ISOMETRIC
N
SHEET NOTES
LEGEND
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
PJL
JMK
21-005657.00
LEVEL 1 PLAN
R-101
07/22/2027
OWNERS REVIEW
3/32" = 1'-0"1
LEVEL 1 PLAN
REFERENCES:
1. GENERAL NOTES, LEGEND, AND R-001
WI SCHEDULE
2. FLOOR & REFLECTED R-100 SERIES
CEILING PLANS
3. REPAIR DETAILS R-500 SERIES
NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING
ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS
IN ACCORDANCE WITH THE SPECIFICATIONS. WORK
ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF
DETERIORATION.
REPAIR - FLOOR
REPAIR - OVERHEAD
TRAFFIC TOPPING - RECOAT
EXISTING EXPANSION JOINT
EXISTING FLOOR DRAIN
FD
WORK ITEM LEGEND:
NOTES:
1. NOT ALL WORK ITEMS HAVE DETAILS.
2. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
X.X.X
WORK ITEM NO
XXX
WORK ITEM NOTE
(SEE ABBREVIATIONS)
CLARIFICATION
DETAIL NO
U P
UP
DN.
UP
DN.
1 2
A
B
B.4
C
3 4 6 7 8 10 11 12 13 13.5 145 9
301'-2"
23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"
3.1
TYP
7.1
95.5.1
11.1
25.3
TYP
6.7
SLAB
16.4
21.13
6.7
COL
11.111.1
16.4
6.1 6.1
6.7
COL
11.2
TYP
7.1
16.5
11.7 6.1
11.1
3.1
3.10
11.2
LEVEL 3
LEVEL 4
LEVEL 5
LEVEL 2
LEVEL 1
LEVEL 6
ISOMETRIC
N
SHEET NOTES
LEGEND
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
PJL
JMK
21-005657.00
LEVEL 2 PLAN
R-102
07/22/2027
OWNERS REVIEW
3/32" = 1'-0"1
LEVEL 2 PLAN
WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES
OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING
IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS
MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR
SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE
ANCHORS CAN NOT BE MORE THAN 1" LONG.
REFERENCES:
1. GENERAL NOTES, LEGEND, AND R-001
WI SCHEDULE
2. FLOOR & REFLECTED R-100 SERIES
CEILING PLANS
3. REPAIR DETAILS R-500 SERIES
NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING
ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS
IN ACCORDANCE WITH THE SPECIFICATIONS. WORK
ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF
DETERIORATION.
REPAIR - FLOOR
REPAIR - OVERHEAD
TRAFFIC TOPPING - RECOAT
EXISTING EXPANSION JOINT
EXISTING FLOOR DRAIN
FD
WORK ITEM LEGEND:
NOTES:
1. NOT ALL WORK ITEMS HAVE DETAILS.
2. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
X.X.X
WORK ITEM NO
XXX
WORK ITEM NOTE
(SEE ABBREVIATIONS)
CLARIFICATION
DETAIL NO
U P
UP
DN.
DN.
UP
FD
FD
1 2
A
B
B.4
C
3 4 6 7 8 10 11 12 13 13.5 145 9
301'-2"
23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"
7.17.17.1
3.10 3.1
TAR
11.1
3.4
11.1
6.7
COL
6.7
SLAB
6.7
SLAB
11.1
21.13
EXISTING
EXPANSION
JOINT
EXISTING
EXPANSION
JOINT
EXISTING
EXPANSION
JOINT
EXISTING
EXPANSION
JOINT
10.1
EXTERIOR
7.1 7.1
3.4 6.7
COL
11.1
16.5 25.3
6.7
COL
6.1
3.1
TYP
11.1
10.1
3.10
3.1
10.10 7.17.17.1
7.1 7.1
6.1 7.1
7.1 7.1 7.1 7.1
4.1
ABOVE
4.1
ABOVE
11.1
3.1
TAR
6.1
LEVEL 3
LEVEL 4
LEVEL 5
LEVEL 2
LEVEL 1
LEVEL 6
ISOMETRIC
N
SHEET NOTES
LEGEND
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
PJL
JMK
21-005657.00
LEVEL 3 PLAN
R-103
07/22/2027
OWNERS REVIEW
3/32" = 1'-0"1
LEVEL 3 PLAN
REFERENCES:
1. GENERAL NOTES, LEGEND, AND R-001
WI SCHEDULE
2. FLOOR & REFLECTED R-100 SERIES
CEILING PLANS
3. REPAIR DETAILS R-500 SERIES
NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING
ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS
IN ACCORDANCE WITH THE SPECIFICATIONS. WORK
ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF
DETERIORATION.
REPAIR - FLOOR
REPAIR - OVERHEAD
TRAFFIC TOPPING - RECOAT
EXISTING EXPANSION JOINT
EXISTING FLOOR DRAIN
FD
WORK ITEM LEGEND:
NOTES:
1. NOT ALL WORK ITEMS HAVE DETAILS.
2. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
X.X.X
WORK ITEM NO
XXX
WORK ITEM NOTE
(SEE ABBREVIATIONS)
CLARIFICATION
DETAIL NO
WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES
OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING
IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS
MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR
SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE
ANCHORS CAN NOT BE MORE THAN 1" LONG.
U P
UP
DN.
UP
DN.
D N
U P
UP
DN.
UP
DN.
1 2
A
B
B.4
C
3 4 6 7 8 10 11 12 13 13.5 145 9
301'-2"
23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"
3.1
11.1
11.7
11.7
3.1
7.1
EXTERIOR
TAR
21.13
7.1
7.1
3.1
10.3
11.1
7.1
7.1 11.1
21.13
11.2
3.1
TYP
3.1
6.1
11.7TYP
TYP
11.2
TAR
11.2
TAR
11.7
TYP
16.4
16.4
6.1
11.1
11.1
TAR
6.1
6.1
11.3
11.1
TAR
6.1
21.137.1 6.1 7.1
3.1
3.10
11.1
TAR
3.1
11.7 11.2
3.1
11.1
TAR
11.2
TAR
3.4
11.1
TAR
10.10
3.1
7.1
7.1
3.10
TAR
TAR
3.10
TAR
3.1
TAR
11.1
3.1
TYP
TRAFFIC
BARRIER
3.4 3.7
TAR
LEVEL 3
LEVEL 4
LEVEL 5
LEVEL 2
LEVEL 1
LEVEL 6
ISOMETRIC
N
SHEET NOTES
LEGEND
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
PJL
JMK
21-005657.00
LEVEL 4 PLAN
R-104
07/22/2027
OWNERS REVIEW
3/32" = 1'-0"1
LEVEL 4 PLAN
REFERENCES:
1. GENERAL NOTES, LEGEND, AND R-001
WI SCHEDULE
2. FLOOR & REFLECTED R-100 SERIES
CEILING PLANS
3. REPAIR DETAILS R-500 SERIES
NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING
ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS
IN ACCORDANCE WITH THE SPECIFICATIONS. WORK
ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF
DETERIORATION.
REPAIR - FLOOR
REPAIR - OVERHEAD
TRAFFIC TOPPING - RECOAT
EXISTING EXPANSION JOINT
EXISTING FLOOR DRAIN
FD
WORK ITEM LEGEND:
NOTES:
1. NOT ALL WORK ITEMS HAVE DETAILS.
2. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
X.X.X
WORK ITEM NO
XXX
WORK ITEM NOTE
(SEE ABBREVIATIONS)
CLARIFICATION
DETAIL NO
WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES
OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING
IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS
MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR
SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE
ANCHORS CAN NOT BE MORE THAN 1" LONG.
U P
DN.
DN.
1 2
A
B
B.4
C
3 4 6 7 8 10 11 12 13 13.5 145 9
301'-2"
23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"
74.11
TAR
3.10
11.7
11.2
11.7 11.2
11.7
11.1
TYP
11.711.2
3.1
10.10
11.1
45.6
6.1
21.13
11.7
74.11
3.1
6.1 11.16.1
11.7
11.7
11.211.1
16.5
74.11
11.7
TAR
11.1
16.5 11.711.7 3.4
11.1
11.2
11.2
11.211.1
11.1
11.1
11.7
3.1
11.7
11.1
6.1
7.1
21.13
11.111.7 21.13
11.7
11.2
TYP
11.1
3.1 11.7
11.2 11.1
4.1
ABOVE
5.1
ABOVE
3.1
TAR
TAR
LEVEL 3
LEVEL 4
LEVEL 5
LEVEL 2
LEVEL 1
LEVEL 6
ISOMETRIC
N
SHEET NOTES
LEGEND
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
PJL
JMK
21-005657.00
LEVEL 5 PLAN
R-105
07/22/2027
OWNERS REVIEW
3/32" = 1'-0"1
LEVEL 5 PLAN
REFERENCES:
1. GENERAL NOTES, LEGEND, AND R-001
WI SCHEDULE
2. FLOOR & REFLECTED R-100 SERIES
CEILING PLANS
3. REPAIR DETAILS R-500 SERIES
NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING
ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS
IN ACCORDANCE WITH THE SPECIFICATIONS. WORK
ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF
DETERIORATION.
REPAIR - FLOOR
REPAIR - OVERHEAD
TRAFFIC TOPPING - RECOAT
EXISTING EXPANSION JOINT
EXISTING FLOOR DRAIN
FD
WORK ITEM LEGEND:
NOTES:
1. NOT ALL WORK ITEMS HAVE DETAILS.
2. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
X.X.X
WORK ITEM NO
XXX
WORK ITEM NOTE
(SEE ABBREVIATIONS)
CLARIFICATION
DETAIL NO
WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES
OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING
IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS
MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR
SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE
ANCHORS CAN NOT BE MORE THAN 1" LONG.
U P
1 2
A
B
B.4
C
3 4 6 7 8 10 11 12 13 13.5 145 9
301'-2"
23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"
3.4
74.11
TAR
3.4
7.1
74.11
TAR
11.7
3.4
3.1
11.7
3.1
11.7
16.4
TYP
11.7
11.7
6.111.711.7
3.1
3.1
3.1
3.4
11.7 16.5
3.1
3.4 11.7
6.1
6.1
74.11
74.11
11.7
84.1
11.7
3.4
74.11
@ WASH,
TYP
TYP
3.1
@ WASH,
TYP
LEVEL 3
LEVEL 4
LEVEL 5
LEVEL 2
LEVEL 1
LEVEL 6
ISOMETRIC
N
SHEET NOTES
LEGEND
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
PJL
JMK
21-005657.00
LEVEL 6 PLAN
R-106
07/22/2027
OWNERS REVIEW
3/32" = 1'-0"1
LEVEL 6 PLAN
REFERENCES:
1. GENERAL NOTES, LEGEND, AND R-001
WI SCHEDULE
2. FLOOR & REFLECTED R-100 SERIES
CEILING PLANS
3. REPAIR DETAILS R-500 SERIES
NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING
ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS
IN ACCORDANCE WITH THE SPECIFICATIONS. WORK
ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF
DETERIORATION.
REPAIR - FLOOR
REPAIR - OVERHEAD
TRAFFIC TOPPING - RECOAT
EXISTING EXPANSION JOINT
EXISTING FLOOR DRAIN
FD
WORK ITEM LEGEND:
NOTES:
1. NOT ALL WORK ITEMS HAVE DETAILS.
2. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
X.X.X
WORK ITEM NO
XXX
WORK ITEM NOTE
(SEE ABBREVIATIONS)
CLARIFICATION
DETAIL NO
WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES
OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING
IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS
MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR
SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE
ANCHORS CAN NOT BE MORE THAN 1" LONG.
SPALL OR DELAMINATION
REMOVE CONCRETE
WITHIN SECTION SHOWN
EXISTING PT TENDON,
DEPTH VARIES
REINFORCEMENT (TYP),
LOCATIONS APPROXIMATE.
CLEAN AND APPLY CORROSION
INHIBITOR TO ALL EXPOSED
REINFORCEMENT. PROVIDE 3/4"
CLEARANCE AROUND ALL
EXPOSED REINFORCEMENT
EXISTING CONCRETE
SLAB
ORIGINAL SURFACE
SAWCUT PATCH
PERIMETER 1/2" (TYP)
VARIES
-4
CAUTION: EMBEDDED CONDUIT, PIPING OR POST-TENSIONING STRAND
CONTAIN DANGEROUS STORED ENERGY. CONFIRM LOCATIONS AND
CONDITION PRIOR TO DEMOLITION.
INSTALL LATEX MODIFIED
CONCRETE OR PREPACKAGED
REPAIR MATERIAL
VARIES
EXIST FLOOR SLAB
REMOVE CONCRETE WITHIN
SECTION SHOWN. PROVIDE RADIUS
AND SLOPE TO MATCH EXISTING.
SAWCUT PATCH
PERIMETER 3/4" (TYP)
REINFORCEMENT (TYP),
LOCATIONS APPROXIMATE.
CLEAN AND APPLY CORROSION
INHIBITOR TO ALL EXPOSED
REINF. PROVIDE 3/4" CLEARANCE
AROUND ALL EXPOSED REINF
WHERE REQ'D AS SPECIFIED IN
SECTION "SURFACE
PREPARATION FOR PATCHING".
REPAIR
CONCRETE SEE WI
3.0
REMOVE CONCRETE WITHIN
SECTION SHOWN
EXIST
CONCRETE
SLAB
WI 11.2, TYP AT ALL
PERIMETER
SAW CUT
PERIMETER TYP
REMOVE EXISTING SLAB 3/4" MIN. DEEP AT LATEX
CONCRETE OVERLAY AREAS AS SPECIFIED IN
SECTION "SURFACE PREPARATION FOR PATCHING"
ORIGINAL SURFACECAUTION: EMBEDDED CONDUIT, PIPING
OR POST-TENSIONING STRAND CONTAIN
DANGEROUS STORED ENERGY. CONFIRM
LOCATIONS AND CONDITION PRIOR TO
DEMOLITION.
/4
SPALL OR
DELAMINATION
EXISTING
CONSTRUCTION JOINT
REMOVE CONCRETE WITHIN
SHADED SECTION SHOWN
CONC SLAB ON GRADE
ORIGINAL SURFACE
SAWCUT PATCH
PERIMETER 3/4" (TYP)
COMPACTED CLASS
5, AS REQUIRED
ADDED REINFORCEMENT /
WWR, REFER TO
SPECIFICATIONS
INSTALL AND SEAL
CONSTRUCTION JOINT TO
MATCH EXISTING, SEE
WORK ITEM 11.2
VARIES
REINFORCEMENT (TYP), LOCATIONS
APPROXIMATE. CLEAN AND APPLY
CORROSION INHIBITOR TO ALL
EXPOSED REINF. PROVIDE 3/4"
CLEARANCE AROUND ALL EXPOSED
REINF. WHERE REQ'D AS SPECIFIED IN
SECTION "SURFACE PREPARATION
FOR PATCHING".
VARIES
SPALL OR
DELAMINATION
REINFORCEMENT (TYP),
LOCATIONS APPROXIMATE. CLEAN
AND APPLY CORROSION
INHIBITOR TO ALL EXPOSED
REINF. PROVIDE 3/4" CLEARANCE
AROUND ALL EXPOSED REINF
WHERE REQ'D AS SPECIFIED IN
SECTION "SURFACE PREPARATION
FOR PATCHING".
GRIND OR SAWCUT
PATCH PERIMETER
1/2" (TYP)
REMOVAL LIMITS
EXIST CONCRETE SLAB
ORIGINAL
SURFACE
REMOVE CONCRETE WITHIN
SECTION SHOWN. ROUGHEN
TO ICRI CSP 7 TO 9.
2"-4"
V A
R
IE
S
REMOVE CONCRETE
WITHIN SECTIONS
SHOWN SHADED, TYP.
ROUGHEN SURFACE
TO ICRI CSP 7 TO 9
VARIES
VARIES
2"-4"
V A
R
IE
S
SPALL OR
DELAMINATION, TYP
REMOVAL
LIMITS, TYP
GRIND OR SAWCUT
PATCH PERIMETER
1/2", TYP
REINFORCEMENT, TYP.
LOCATIONS APPROXIMATE CLEAN
AND APPLY CORROSION
INHIBITOR TO ALL EXPOSED
REINF. PROVIDE 3/4" CLEARANCE
AROUND ALL EXPOSED REINF
WHERE REQ'D AS SPECIFIED IN
SECTION "SURFACE
PREPARATION FOR PATCHING".
P A
Y U
N
IT
P A
Y U
N
IT
P A
Y U
N
IT
DEPTH OF REMOVAL
FOR THIS WORK ITEM.
SETTING UP PAY UNITS
THIS WAY ELIMINATES
DOUBLE PAY FOR
CORNERS TYP FOR
BEAMS AND COLUMNS
CAUTION, LONGITUDINAL
REINF MAY BE
PRESTRESSED AND
CONTAIN DANGEROUS
STORED ENERGY.CONFIRM
BEFORE REMOVAL
PAY UNIT
REMOVAL LIMITSGRIND OR SAWCUT
PATCH PERIMETER
3/4" (TYP)
REMOVE CONCRETE
WITHIN SECTION
SHOWN SHADED
(TYP) ROUGHEN
SURFACE TO
ICRI CSP 7 TO 9, TYP
REINFORCEMENT (TYP),
LOCATIONS APPROXIMATE.
CLEAN AND APPLY CORROSION
INHIBITOR TO ALL EXPOSED
REINF. PROVIDE 3/4"
CLEARANCE AROUND ALL
EXPOSED REINF WHERE REQ'D
AS SPECIFIED IN SECTION
"SURFACE PREPARATION FOR
PATCHING".
SPALL OR
DELAMINATION
(TYP)
REPAIR CONCRETE
NOTES:
1. COLUMN TIES WHICH HAVE LOST MORE THAN 15% OF ORIGINAL CROSS
SECTIONAL AREA SHALL BE SUPPLEMENTED AS ENGINEER DIRECTS.
2. NUMBER AND LOCATION OF REINFORCEMENT SHOWN MAY DIFFER FROM
ACTUAL FIELD CONDITIONS.
2"-4"2"-4"
V A
R
IE
S
V A
R
IE
S
EXIST PT
ANCHORS, ACTUAL
DEPTH AND
LOCATION VARIES.
CLEAN AND COAT
WITH A RUST
INHIBITING COATING
DETERIORATED CONC
REMOVAL AND
REPLACEMENT
AREA
SAWCUT PERIMETER 3/4",
ROUGHEN SURFACE TO CSP 7 TO 9
PRIOR TO GROUT PLACEMENT.
REPLACE MORTAR TO ITS
ORIGINAL DIMENSION AND
SURFACE FINISH
PT CONC SLAB
OR BEAM
PT CONC
COLUMN
2" - 4"
V A
R
IE
S
EXIST FACE OF WALL
SPALL OR DELAMINATION
REINFORCEMENT (TYP),
LOCATIONS APPROXIMATE.
CLEAN AND APPLY
CORROSION INHIBITOR TO ALL
EXPOSED REINF. PROVIDE 3/4"
CLEARANCE AROUND ALL
EXPOSED REINF WHERE
REQ'D AS SPECIFIED IN
SECTION "SURFACE
PREPARATION FOR
PATCHING".
GRIND OR SAWCUT PATCH
ROUGHEN SURFACE TO ICRI
CSP 7 TO 9, TYP
TROWEL APPLIED
MORTAR. SEE NOTE 1
INSTALL PATCH
FLUSH WITH WALL
NOTE:
1. FOR WALL PANELS WITH ARCHITECTURAL FINISHES REFER TO WORK ITEM SPECIFICATIONS 91.4.
4" SAW CUT STAIR
ENTIRE WIDTH
CONCRETE REPAIR MORTAR
(SEE SPECIFICATIONS)
R 1/2"
EXISTING CAVITY
SURFACE
TRAFFIC
TOPPING ON
RISE, RUN &
SIDES OF STAIRS
(WI 16.1)
SAW CUT STAIR
ENTIRE WIDTH
3/ 4"
3" M
IN
1/2"
/2
NOTES:
1. REMOVE EXISTING CAST IRON NOSING AND ANCHOR DEVICES.
2. REMOVE AND REPLACE ALL SOUND AND UNSOUND CONCRETE
WITHIN SECTION SHOWN CROSS HATCHED.
#3 EPOXY COATED
SET IN EPOXY
ALUMINUM NOSING
EQUAL TO
"STAIRMASTER"
TYPE 540, TYP
3'-0"
#3
REPAIR NOTES:
1. DIMENSION VARIES.
2. REPAIR VOIDS / CHIPS.
3. REMOVE HIGH SPOTS.
4. REPAIR SPALLED EDGES.
5. REMOVE OVERHANGS.
6. REMOVE SLOPE ON SURFACE.
7. PROVIDE SURFACES TO BE LEVEL / PLUMB.
#6
#5
#6
#7#2
#4
CONCRETE SUBSTRATE
EXPANSION JOINT
BLOCKOUT AND
PROFILE
SEE DETAIL WI 10.3
CAUTION: EMBEDDED CONDUIT, PIPING OR
POST-TENSIONING STRAND CONTAIN
DANGEROUS STORED ENERGY. CONFIRM
LOCATIONS AND CONDITON PRIOR TO
DEMOLITION.
#1
8. WORK SHOWN HERE IS INCIDENTAL TO W.I. SERIES 10.0.
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
AM
JMK
21-005657.00
REPAIR DETAILS
R-501
07/22/2027
OWNERS REVIEW
3.1
FLOOR REPAIR - PARTIAL DEPTH/SHALLOW
3.4
FLOOR REPAIR - CURBS / WALKS
3.7
FLOOR REPAIR - CONCRETE WASHES
3.11
FLOOR REPAIR- SLAB-ON-GRADE
4.1
CEILING REPAIR - PARTIAL DEPTH/SHALLOW
5.1
BEAM REPAIR - PARTIAL DEPTH/SHALLOW
6.1
COLUMN REPAIR - PARTIAL DEPTH/SHALLOW
6.7
COLUMN/SLAB REPAIR - GROUT PLUG
7.1
WALL REPAIR - PARTIAL DEPTH/SHALLOW
3.10
FLOOR REPAIR - STEEL STAIR NOSING REPAIR
REVISIONS
MARK DATE DESCRIPTION
9.1.1
EXPANSION JOINT PREPARATION- TYPICAL BLOCKOUT REPAIRS
(FOR REFERENCE)
EXISTING CONCRETE
ELASTOMERIC CONCRETE
HEADER, TYP
WBA W/ ME MEMBRANE
GLAND OR ENGINEER
APPROVED EQUAL
TYP
3 1/2" MIN
TYP
2 1/2" MIN
/4
FLOOR TO FLOOR
NOTE:
1. CONTRACTOR SHALL, WITH MANUFACTURER, VERIFY FIELD INSTALLATION WIDTH
BASED ON TEMPERATURE CONDITIONS.
2. PROVIDE SHOP DRAWINGS SHOWING JOINT INTERSECTIONS AND WALL TERMINATIONS.
VIF
REPAIR EXPANSION JOINT
BLOCKOUT AS REQUIRED.
REFER TO DETAIL 9.1.1
EXISTING CONCRETE
ELASTOMERIC CONCRETE
HEADER, TYP
REPAIR NOSING PER
MANUFACTURERS REQUIREMENTS
EXISTING WING-TYPE
GLAND SYSTEM
FIELD VERIFY
V
IF
NOTES:
1. PAYMENT IS BASED ON ONE SIDE OF JOINT ONLY.
/4
EXISTING CRACK. CENTER
ROUTED GROOVE ON CRACK
ROUT CRACK WITH 'V' BLADE
AND FILL W/ FLEXIBLE SEALANT.
INSTALL SEALANT 1/16" BELOW
ADJACENT SURFACES, OR
FLUSH W/ ADJACENT SURFACES
TO RECEIVE TRAFFIC COATING.
DO NOT OVERFILL JOINT.
EXIST CONCRETE
EXISTING CONCRETE
EXISTING CRACK
REMOVE ALL EXISTING SEALANT,
PREPARE SUBSTRATE, AND FILL
W/FLEXIBLE SEALANT. INSTALL
SEALANT FLUSH W/ SURFACE.
DO NOT OVERFILL JOINT.
BOND BREAKER TO SEPARATE
SEALANT FROM CONCRETE AT
BOTTOM OF JOINT
1/2"
3/8"
/1
/2
EXIST SUBSTRATE
NOTES:
1. CLEAN JOINT SUBSTRATE BY SAND & AIR BLASTING.
2. PREPARE AND PRIME SEALANT CAVITY & INSTALL SEALANT ACCORDING TO
SEALANT MANUFACTURER'S RECOMMENDATIONS.
SEALANT
BACKER ROD
3/4" ±
THROAT DEPTH 1/2
JOINT WIDTH
SEALANT MATERIAL,
SEE NOTE 1.
EXIST FINISHED
FLOOR SURFACE
EXIST VERTICAL
SURFACE
NOTES:
1. REMOVE ALL EXISTING COVE SEALANT MATERIAL IF PRESENT. PREPARE
SURFACE PER SPECIFICATIONS.
2. A PRIMER COAT IS REQUIRED FOR ALL SYSTEMS.
1/ 2"
3/4"
/4
HORIZ / VERT
TRANSITION
COVE SEALANT
SEE DETAIL 11.7
LIMITS OF SURFACE
PREPARATION
VERTICAL SURFACE
(WALL OR COLUMNS)
CONTRACTOR TO PROVIDE
STRAIGHT FINISHED LINE
CRACKS < 1/32"
ISOMETRIC
PROVIDE 4" WIDE DETAIL
COAT CENTERED OVER
ALL CRACKS LESS THAN
1/32" WIDE
CRACKS > 1/32"
(OR MOVING CRACKS)
ROUT AND SEAL CRACKS GREATER
THAN 1/32" WIDTH. REMOVE AND
REPLACE ALL EXIST CRACK/JOINT
SEALANT. SEE DETAILS 11.1 OR 11.2.
PROVIDE 4" WIDE DETAIL COAT
CENTERED OVER CRACK
TRAFFIC TOPPING (FLOOR
SURFACE OR CURB)
NOTE:
1. QUANTITIES BASED ON HORIZONTAL APPLICATION AREA. VERTICAL DETAILING, ADDITIONAL
DETAIL COAT OVER CRACKS, ROUTING AND SEALING CRACKS, INSTALLATION OF COVE SEALANT, AND REMOVAL AND REPLACEMENT OF EXISTING SEALANTS ARE INCIDENTAL TO THIS WORK.
REPLACE
PRE-MOLDED JOINT
MAINTAIN 1/2"
SEPERATION FOR JOINT
AT PERIMETER
KEEP EXIST ADHESIVE
JOINT
INSTALL WEDGES &
POWER SEAT WEDGES
TO CABLE 80% MUTSSTEP 1 - SEAT DEAD END (FIRST BACK STRESS)
JACK AGAINST
COLUMN OR
SPLICE COUPLER
INSTALL WEDGES STRESS
CABLE TO SPECIFIED FORCE
STRESSING FORCE IS 3
KIPS INCLUDING WEDGE
SEATING LOSSES
STEP 3 - SEAT LIVE END (SECOND BACKSTRESSING)
STEP 2 - TENSION CABLE
POWER SEAT
INSTALLED WEDGES
TO 80% MUTS
EXISTING
ANCHOR, REUSE
IF APPLICABLE
EXISTING
ANCHOR, REUSE
IF APPLICABLE
JACK AGAINST
COLUMN OR
SPLICE COUPLER
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
PJL
JMK
21-005657.00
REPAIR DETAILS
R-502
07/22/2027
OWNERS REVIEW
10.3
EXPANSION JOINT - ELASTOMERIC CONCRETE EDGED
10.10
EXPANSION JOINT - HEADER REPAIR
11.1
SEAL CRACKS AND JOINTS
11.2
REPAIR CRACK/JOINT SEALANT
11.3
VERTICAL JOINT SEALANT
11.7
COVE SEALANT
16.4
TRAFFIC TOPPING - RECOAT (PARTIAL SYSTEM)
16.5
TRAFFIC TOPPING - RECOAT (COMPLETE SYSTEM)
10.1
EXPANSION JOINT - PREMOLDED (FLOOR TO FLOOR)
16.5
TRAFFIC TOPPING - VEHICULAR
REVISIONS
MARK DATE DESCRIPTION
21.13
REPLACE BARRIER CABLE
CONCRETE SLAB
INSTALL
CLEAN-OUTCONNECT TO EXISTING DRAIN LINE.
HOLD AS HIGH AS POSSIBLE.
MAINTAIN 1/8" PER FT MINIMUM PITCH.
HANGERS WITH .75 IN
MIN ROD DIA @ 5'-0" OC
MAX PER WI 25.3
NEW 6" PIPE (4"
PIPE AT COVERED
LEVELS)
NOTES:
1. USE SERVICE WEIGHT CAST IRON PIPE. ALL MATERIALS SHALL BE IN ACCORDANCE WITH
PREVAILING BUILDING ORDINANCES.
2. INSTALL ADJUSTABLE HANGERS AS REQUIRED, VERIFY MINIMUM HEIGHT RESTRICTIONS OF
PREVAILING BUILDING ORDINANCES PRIOR TO INSTALLATION.
W I
.3
EXIST
SUBSTRATE
NOTES:
1. CLEAN JOINT SUBSTRATE BY SAND & AIR BLASTING.
2. PREPARE AND PRIME SEALANT CAVITY & INSTALL SEALANT ACCORDING TO SEALANT
MANUFACTURER'S RECOMMENDATIONS.
3. CONTRACTOR SHALL, WITH MANUFACTURER, VERIFY FIELD INSTALLATION WIDTH
BASED ON TEMPERATURE CONDITIONS. TOTAL ANTICIPATED JOINT MOVEMENT -
COORDINATE JOINT MOVEMENT WITH ENGINEER
VIF
VARIES
EXIST
SUBSTRATE
FIELD-APPLIED SILICONE
CORNER BEADS AND SILICONE
BAND FORCED DOWN ALONG
SIDE OF JOINT AS SHOWN-BOTH
SIDES
FIELD APPLIED SEALANT
CONTINUOUS BOTH SIDES
PREFORMED ELASTOMERIC
SEAL, RECESSED
ADHESIVE
BOTH SIDES
74.11
APPLY BASE COAT & MESH
REINFORCING TO PATCH
AREA AND OVERLAP
EXISTING MESH 3"
REMOVE DAMAGED
EIFS FULL DEPTH TO
SUBSTRATE
SQUARE CUT
REPAIR AREA
CUT NEW INSULATION
REPLACEMENT PLUG TO
FIT SNUG. FIX IN PLACE
WITH EIFS ADHESIVE OR
MECHANICAL FASTENER
INSTALL FINISH COAT
OVER REPAIR AREA -
MATCH FINISH &
TEXTURE OF
SURROUNDING AREA
FINISH COAT REMOVED
AND INTACT BASE
COAT AND MESH
EXPOSED
EDGE OF FINISH COAT
(SHARP EDGE) MASK
SURROUNDING WALL
AREA
EXISTING
UNDAMAGED EIFS
REPAIRPREPARATION WORK
T Y
P
CHECKED BY:
SHEET TITLE:
DRAWN BY:
PROJECT NO:
COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO
PART OF THIS DOCUMENT MAY BE REPRODUCED
IN ANY FORM OR BY ANY MEANS WITHOUT
PERMISSION FROM WALKER CONSULTANTS.
7760 France Ave S, Suite 820 Minneapolis, MN 55435
952.595.9116 Ph
www.walkerconsultants.com
ISSUE DATE:
ISSUE:
I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.
/8
/2
:5
:3
A
M A u to d e s k D o c s /2
-0
.0
M
N R e s to
P ro je c ts
R e v it
.0
.0
M
C C
R
.r v t
1403 3RD AVE S
MINNEAPOLIS, MN 55404
CONVENTION CENTER
P R
E L
IM
IN
A R
Y
D O
N O
T U
S E
F O
R C
O N
S T
R U
C T
IO
N
PARKING FACILITY REPAIRS
PJL
JMK
21-005657.00
REPAIR DETAILS
R-503
07/22/2027
OWNERS REVIEW
25.3
MECHANICAL - PIPE AND HANGERS
74.11
INSTALL PREFORMED JOINT SEALANT
84.1
REPAIR EXISTING EIFS CLADDING
File details come from the government source that posted it. Updated .