This is an architectural drawing set prepared by Walker Consultants for the Convention Center Parking Facility Repairs project located at 1403 3rd Avenue South, Minneapolis, Minnesota 55404. The project, identified as Project No. 21-005657.00, involves selective demolition and repair of structural building elements across six parking levels, including concrete floor repairs, overhead repairs, traffic topping applications, expansion joint restoration, and miscellaneous repairs to columns, beams, walls, and mechanical systems. The drawing set includes a cover sheet, general notes and legends with work item schedules, level plans for all six floors, and detailed repair specifications. The facility must remain operational during construction with phasing constraints requiring maintenance of minimum pedestrian access widths of 6 feet and headroom of 7 feet, temporary vehicular one-way travel lanes of minimum 12 feet, and coordinated parking space closures that do not exceed specified limits at any given time. The drawings are marked as preliminary and dated July 22, 2027, for owners' review.

The construction documents shall be performed in accordance with all applicable federal, state of Minnesota, and City of Minneapolis codes and ordinances, including fire codes. All work must be field-verified prior to fabrication and construction, with the contractor responsible for determining actual extent and locations of repair areas as specified in the construction specifications section. Critical safety considerations include post-tensioning tendons embedded near both surfaces of floor slabs that may break with explosive force if cut, requiring contractor precautions and verification prior to any cutting or anchor installation. The contractor must submit a construction and shoring program two weeks prior to work commencement, provide all temporary shoring and bracing, and submit stamped calculations and plans prepared by a Minnesota-licensed professional engineer. Concrete specifications require 5000 PSI compressive strength at 28 days, a maximum water-cement ratio of 0.40, and epoxy coating of all reinforcement except welded wire reinforcement. All existing services and utilities must be maintained during repair work, with temporary connections requiring owner approval prior to commencement.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR BY ANY MEANS WITHOUT PERMISSION FROM WALKER CONSULTANTS.

ENGINEER

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

PARKING FACILITY REPAIRS

JULY 22, 2027

OWNERS REVIEW

PROJECT NO: 21-005657.00

DRAWING INDEX

NO: SHEET NAME

RESTORATION

R-000 COVER SHEET AND SITE LOCATION MAP

R-001 GENERAL NOTES, LEGENDS, & WORK ITEM SCHEDULE

R-101 LEVEL 1 PLAN

R-102 LEVEL 2 PLAN

R-103 LEVEL 3 PLAN

R-104 LEVEL 4 PLAN

R-105 LEVEL 5 PLAN

R-106 LEVEL 6 PLAN

R-501 REPAIR DETAILS

R-502 REPAIR DETAILS

R-503 REPAIR DETAILS

PROJECT

SITE

IMAGE: GOOGLE MAPS

IMAGE: GOOGLE MAPS

LEVEL 3

LEVEL 4

LEVEL 5

LEVEL 2

LEVEL 1

LEVEL 6

ISOMETRIC

GENERAL RESTORATION NOTES

A. CONSTRUCTION

1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE, OF

MINNESOTA, AND CITY OF MINNEAPOLIS CODES AND ORDINANCES, INCLUDING FIRE CODES.

2. ALL MATERIAL PROPERTIES SHALL BE AS NOTED IN SPECIFICATIONS.

3. PRIOR TO FABRICATION OF ANY MATERIAL OR PLACEMENT OF CONCRETE, FIELD VERIFY ALL

EXISTING DIMENSIONS AND CONDITIONS AS SHOWN ON DRAWINGS. REPORT ALL

4. DO NOT SCALE DRAWINGS

B. CONSTRUCTION DOCUMENTS

1. CONSTRUCTION DOCUMENTS ENTITLED "CONVENTION CENTER PARKING FACILITY REPAIRS 2026"

INCLUDES THESE DRAWINGS AND SEPARATELY BOUND SPECIFICATIONS. FOR PURPOSE OF

PERFORMING THE WORK, DRAWINGS AND SPECIFICATIONS SHALL BE A SINGLE UNIT.

2. DIMENSIONS SHOWN ON PLANS ARE BASED ON ORIGINAL CONSTRUCTION DOCUMENTS. THE

CONTRACTOR IS REQUIRED TO FIELD VERIFY ALL CONDITIONS FOR THE PURPOSES OF

PREPARING THE BID IN PERFORMING THE WORK.

3. REFER TO SPECIFICATION SECTION 020010 FOR SCOPE, DESCRIPTION, AND REQUIREMENTS OF

THE WORK.

C. DETAILS AND SYMBOLS

1. ALL CONCRETE REPAIR DETAILS ARE SHOWN ON DRAWING SERIES R-500.

2. DETAILS LABELED "FOR ALL CLARIFICATION ONLY" DO NOT REPRESENT A SEPARATE PRICE ITEM.

THESE DETAILS SUPPLEMENT THE BASIC DETAIL TO PROVIDE ADDITIONAL INFORMATION IN SOME

CASES THESE DETAILS SHOW VARIATIONS OF THE TYPICAL CONDITION.

3. WHEN THE WORK ITEM BUBBLE IS NOTED (TYP), IT MEANS THE WORK ITEM OCCURS AT ALL

LOCATIONS WITH THE APPLICABLE DETERIORATION OR DESIGNATION SYMBOL OCCURS ON A

PLAN.

4. WHERE (TAR) IS NOTED, IT MEANS THERE MAY BE AREAS OF THIS WORK IN ADDITION TO THE

PARTICULAR DESIGNATED AREAS

5. WHERE TWO OR MORE WORK ITEM BUBBLES ARE SHOWN GROUPED TOGETHER, IT MEANS ANY

OR ALL OF THE DESIGNATED WORK SHOWN MAY APPLICABLE. COORDINATION OF WORK ITEMS IS

THE CONTRACTOR'S RESPONSIBILITY.

6. WHEN WORK ITEM DETAILS ARE LISTED AS INCIDENTAL, THIS WORK IS INCLUDED IN THE

PAYMENT OF THE OTHER WORK ITEM AND DOES NOT HAVE A SEPARATE PRICE.

7. WHEN THE DETAIL IS LABELED FOR REFERENCE ONLY IT PROVIDES INFORMATION ABOUT

INCIDENTAL WORK AND DOES NOT HAVE A PAY UNIT.

8. CONTRACTOR IS RESPONSIBLE FOR DETERMINING ACTUAL EXTENT AND LOCATIONS OF REPAIR

AREAS IN ACCORDANCE WITH THE SPECIFICATIONS: WORK ITEMS ARE SHOWN ONLY TO

REPRESENT THE TYPES OF DETERIORATION.

9. SEE WORK ITEM SPECIFICATION FOR INFORMATION REGARDING DETAILS.

D. CONCRETE PROTECTION FOR REINFORCEMENT

1. THE FOLLOWING APPLIES FOR FULL SECTION CONCRETE REPLACEMENT OR PARTIAL DEPTH

REPAIRS AS SHOWN ON THE DRAWINGS.

2. THE MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE PER ACI 318-14, SECTION

7.7

3. MINIMUM COVER FOR REINFORCING IN NON-PRESTRESSED CONCRETE AND NON-POST TENSION

MEMBERS.

CONCRETE COVER

(INCHES)

a. SLAB TOP REINFORCEMENT 1 1/2

b. SLAB BOTTOM REINFORCEMENT 3/4

c. BEAM TOP REINFORCEMENT, U.N. 3

d. BEAM SIDE AND BOTTOM (#5 OR SMALLER) 1 1/2

e. BEAM SIDE AND BOTTOM (#6 OR GREATER) 2 1/2

f. COLUMN TIES 1 1/2

*OR 3X BAR DIAMETER, WHICHEVER IS GREATER.

E. EPOXY COATING FOR REINFORCEMENT AND ANCHORS.

1. EPOXY COAT ALL REINFORCEMENT, EXCEPT WELDED WIRE REINFORCEMENT, IN CAST IN PLACE

CONCRETE.

F. SHORING AND BRACING

1. THE SCOPE OF THIS PROJECT INVOLVES SELECTIVE DEMOLITION AND REPAIR OF STRUCTURAL

BUILDING ELEMENTS THAT WILL REQUIRE TEMPORARY SHORING OF EXISTING AND NEW

CONSTRUCTION TO REMAIN. CONTRACTOR SHALL GENERATE A CONSTRUCTION/SHORING

PROGRAM AND SUBMIT TO ENGINEER FOR RECORD TWO (2) WEEKS PRIOR TO THE

COMMENCEMENT OF WORK.

2. CONTRACTOR SHALL PROVIDE ALL SHORING, BRACING, SHEETING, ETC. REQUIRED FOR SAFETY

AND PROPER EXECUTION OF THE WORK.

3. CONTRACTOR IS SOLELY RESPONSIBLE TO PREPARE SHOP DRAWINGS FOR BRACING ENSURING

MEMBERS DESIGNED AND STAMPED/SEALED BY A REGISTERED PROFESSIONAL ENGINEER

(REGISTERED IN THE STATE OF MINNESOTA) AND SUBMIT THEM TO THE ENGINEER FOR RECORD.

4. THE CONTRACTOR SHALL PROVIDE STAMPED/SIGNED CALCULATIONS, PLANS AND DETAILS FOR

THE TEMPORARY SUPPORT OF NEW AND EXISTING CONSTRUCTION TO REMAIN PREPARED BY AN

ENGINEER LICENSED TO PRACTICE IN THE STATE OF MINNESOTA.

G. EXISTING SERVICES AND UTILITIES

1. CONTRACTOR SHALL REVIEW ALL EXISTING CONDITIONS TO DETERMINE ALL ELECTRICAL AND

MECHANICAL SERVICES AND UTILITIES AFFECTED BY THE REPAIR WORK. MAKE ALL NECESSARY

TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SERVICES TO ALL AREAS OF THE BUILDING

OR OTHER AREAS (NOT IN CONTRACT) AFFECTED BY WORK. THE CONTRACTOR SHALL SUBMIT

THE METHODS AND SCHEDULE TEMPORARY CONNECTIONS FOR THE OWNER'S APPROVAL PRIOR

TO COMMENCEMENT.

H. CAST-IN-PLACE CONCRETE.

1. CONCRETE REINFORCEMENT REQUIREMENTS SEE SECTION 020010 FOR SPECIFIC USES

2. CAST IN PLACE CONVENTIONAL CONCRETE

a. COMPRESSIVE STRENGTH 5000 PSI AT 28 DAYS (2500 @ 3 DAYS)

b. WATER-CEMENT RATIO 0.40 MAX

c. MAX SIZE AGGREGATE 1/2 INCH (SELECT LARGER AGG FOR

SECTION GREATER THAN 1/2 INCH)

d. SLUMP (MAXIMUM) 6" WITH SUPER PLASTICIZER

(AFTER WATER REDUCER ADDITION)

e. AIR CONTENT 7% ± 1 1/2%

f. CEMETITIOUS

MATERIAL CONTENT 658 LB/CY MIN*

MAXIMUM PERMISSIBLE CEMENTITIOUS CONTENT

a. FLY ASH: (TYPE F ONLY) 25%

b. SLAG: 50%

c. FLY ASH & SLAG: 50%

3. ALL CONCRETE SPATTER CREATED DURING CONSTRUCTION AND CONSTRUCTION DEBRIS SHALL

BE REMOVED FROM ALL EXISTING COMPONENTS.

4. ANY PAINTED / STAINED ELEMENTS DAMAGED BY ANY CONSTRUCTION ACTIVITIES SHALL BE

RESTORED / PAINTED / STAINED TO MATCH PRE-CONSTRUCTION CONDITION.

5. FLY ASH TYPE F ONLY.

I. ABBREVIATIONS

1. APPROX = APPROXIMATELY

2. AGG = AGGREGATE

3. BM = BEAM

4. BOT = BOTTOM

5. CIP = CAST IN PLACE

6. CJ = CONSTRUCTION JOINT/CONTROL JOINT

7. CLR = CLEARANCE

8. COL = COLUMN

9. CONC = CONCRETE

10. DET = DETAIL

11. EA = EACH

12. EE = EACH END

13. ES = EACH SIDE

14. EMBED = EMBEDMENT LENGTH

15. EJ = EXPANSION JOINT

16. EXIST = EXISTING

17. FIN = FINISHED

18. FL = FLOOR

19. HORIZ = HORIZONTAL

20. IN = INCHES

21. INC = INCIDENTAL

22. LF = LINEAR FOOT

23. LS = LUMP SUM

24. MAX = MAXIMUM

25. MIN = MINIMUM

26. N/A = NOT APPLICABLE

27. OC = ON CENTER

28. OCA = ON CEILING ABOVE

29. OH = OPPOSITE HAND

30. P/C = PRECAST

31. P-T = POST-TENSIONING

32. REINF = REINFORCEMENT

33. REQ'D = REQUIRED

34. SF = SQUARE FOOT

35. SIM = SIMILAR

36. SOG = SLAB ON GROUND

37. SPEC = SPECIFICATION

38. SUPT = SUPPORTED

39. TAR = TYPICAL AS REQUIRED

40. TYP = TYPICAL

41. UN OR UNO = UNLESS NOTED OTHERWISE

42. VERT = VERTICAL

43. VIF = VERIFY IN FIELD

44. WI = WORK ITEM

45. WWR = WELDED WIRE REINFORCEMENT

J. ELECTRICAL CAUTIONARY NOTES

1. UNKNOWN IF SLAB CONTAINS EMBEDDED ELECTRICAL CONDUIT. CONTRACTOR SHALL TAKE ALL

PRECAUTIONS NECESSARY TO AVOID CUTTING/DAMAGING CONDUIT. IF CONDUIT IS DAMAGE AS

RESULT OF CONSTRUCTION OPERATIONS NOTIFY OWNER AND ENGINEER IMMEDIATELY. CONDUIT

DAMAGE BY CONSTRUCTION OPERATION SHALL BE REPAIRED BY CONTRACTOR AT NO COST TO

OWNER. DAMAGED CONDUIT THAT IS NOT A RESULT OF CONSTRUCTION OPERATIONS SHALL BE

REPAIRED/REPLACED PER ELECTRICAL ALLOWANCE.

K. PHASING

a. PHASING SHALL BE AS SCHEDULED BY THE CONTRACTOR AND APPROVED BY THE

ENGINEER/OWNER.

b. GARAGE SHALL REMAIN OPERATION ALL TIMES. FOR PARKING SPACE CLOSURE LIMITS SEE

SPECIFICATION SECTION "SUMMARY OF WORK FOR RESTORATION."

c. WHILE THE GARAGE IS OPERATING FOR CONCRETE REPAIRS AND TRAFFIC TOPPING INSTALLATION

THE ACTUAL NUMBER OF SPACES TAKEN OUT OF SERVICE AT ANY ONE TIME WILL VARY

DEPENDING UPON THE TIME OF YEAR. THE NUMBER OF SPACES WILL BE COORDINATED WITH THE

OWNER/GARAGE OPERATOR.

d. THE CONTRACTOR SHALL PROVIDE UNOBSTRUCTED PEDESTRIAN ACCESS (PROTECTED WHEN

NECESSARY) TO ALL EMERGENCY EGRESS STAIRS AT ALL TIMES. THE CONTRACTOR SHALL

INSTALL AND MAINTAIN SIGNAGE THAT CLEARLY DIRECTS PATRONS TO AND FROM THESE

DESTINATIONS. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN LIGHTING FOR THESE PATHS IN

THE EVENT THE GARAGE LIGHTING IS BLOCKED OR REDUCED BY PROJECT RELATED WORK.

e. IT SHALL BE THE OWNER OR HIS AGENT'S RESPONSIBILITY TO CLEAR WORK PHASE AREA OF VEHICLES. THE CONTRACTOR SHALL WORK IN UNISON WITH THE CLEARING OPERATION TO CAPTURE

THE AREAS BY INCREMENTALLY INSTALLING BARRICADES TO PREVENT VEHICLES FROM

REENTERING THE AREA AS IT IS CLEARED. IN ADDITION TEMPORARY SIGNAGE SHALL BE

INSTALLED AND ADJUSTED BY THE CONTRACTOR DURING THE WORK/PROTECTION ZONE CAPTURE

EFFORT. NOTE THAT NEW AREAS CANNOT BE CAPTURED PRIOR TO WORK ZONES OR PORTIONS

THEREOF BEING RETURNED TO SERVICE SO THAT THE MAXIMUM NUMBER OF SPACES OUT OF

SERVICE SHALL NOT BE EXCEEDED. ALLOW 24 HOURS BETWEEN THE TURNING SPACES TO SERVICE

AN OCCUPYING EQUAL NUMBER OF SPACES FOR THE NEXT PHASE OF WORK.

f. BARRICADES SHALL BE OF SUFFICIENT CONSTRUCTION TO PREVENT INADVERTENT ACCESS BY PATRON VEHICLES AND PEDESTRIANS. THE BARRICADES CAN BE INCORPORATED INTO THE WORK

ZONE PROTECTION THAT ARE INTENDED TO PREVENT THE ESCAPE OF DUST AND OTHER DEBRIS

FROM THE WORK ZONE.

g. THE FOLLOWING PARAMETERS SHALL BE CONSIDERED WHEN DEVELOPING PHASING PLANS.

PEDESTRIAN PATH WIDTH(MINIMUM): 6'-0"

PEDESTRIAN PATH HEADROOM(MINIMUM): 7'-0"

TEMPORARY VEHICLE ONE-WAY TRAVEL(MINIMUM): 12'-0"

TEMPORARY VEHICLE HEAD ROOM HEIGHT: AS POSTED AT

GARAGE ENTRANCE

h. CONTRACTOR SHALL BE RESPONSIBLE TO LOCKOUT STAIR ACCESS INTO WORK, WORK PHASE, AND

AREAS UNDER CONSTRUCTION TO PREVENT UNAUTHORIZED PATRON ACCESS. DOOR SHALL BE

SEALED OFF TO PREVENT AIRBORNE DUST FROM ENTERING INTO STAIRWAYS AND ELEVATOR

SHAFTS.

3. MISCELLANEOUS NOTES

a. OWNER AND THE ENGINEER RESERVE THE RIGHT TO ISSUE A STOP WORK ORDER FOR SPECIFIC AREAS/WORK ITEMS IF IN THE OPINION OF EITHER ONGOING WORK DOES NOT MEET THE PHASING

PARAMETERS OF THE PROJECT OR PRESENT HAZARDS TO THE PATRONS OF THE GARAGE.

CONTRACTOR SHALL NOT BE ENTITLED TO ADDITIONAL COMPENSATION.

b. THE PHASING CONCEPTS CONTAINED IN THESE DOCUMENTS ARE INTENDED TO INDICATE

REASONABLE SCENARIOS FOR PHASING THE WORK. NOT ALL INFORMATION REQUIRED FOR

CONTRACTOR PHASING SUBMITTALS ARE INCLUDED IN THESE CONCEPTS AND THEY DO NOT I

NCLUDE ALL CHALLENGES THAT WILL BE PRESENT IN PERFORMING THIS PROJECT IN A PHASED

MANNER.

c. WORK ZONES SHALL NOT BE RETURNED TO SERVICE IF HAZARDOUS CONDITIONS ARE PRESENT.

d. DO NOT RETURN AREAS TO SERVICE UNLESS EXISTING STRIPING AFFECTED BY WORK HAS BEEN

RESTORED OR NEW STRIPING HAS BEEN APPLIED.

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

License No 5091 Date: 07/22/2026

Patrick J. Lewis, PE

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

PJL

JMK

21-005657.00

GENERAL NOTES,

LEGENDS, & WORK ITEM

SCHEDULE

R-001

07/22/2027

OWNERS REVIEW

WORK ITEM LEGEND:

NOTES:

1. NOT ALL WORK ITEMS HAVE DETAILS.

2. SEE SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

X.X.X

WORK ITEM NO

XXX

WORK ITEM NOTE

(SEE ABBREVIATIONS)

CLARIFICATION

DETAIL NO

WORK ITEM LIST

REVISIONS

MARK DATE DESCRIPTION

D N

U P

FD FD

FDFD

1 2

A

B

B.4

C

3 4 6 7 8 10 11 12 13 13.5 145

301'-2"

23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"

3.11

25.3

3.11

TYP

3.11

3.11

3.11

3.11

6.7

SLAB

7.1

3.11

7.1

11.3 6.7

COL

45.4

7.1

6.7

COL

6.7

COL 6.1

25.3

3.11

30.1

ELEC BOX

30.1

ELEC BOX 3.11

30.1

ELEC BOX

LEVEL 3

LEVEL 4

LEVEL 5

LEVEL 2

LEVEL 1

LEVEL 6

ISOMETRIC

N

SHEET NOTES

LEGEND

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

PJL

JMK

21-005657.00

LEVEL 1 PLAN

R-101

07/22/2027

OWNERS REVIEW

3/32" = 1'-0"1

LEVEL 1 PLAN

REFERENCES:

1. GENERAL NOTES, LEGEND, AND R-001

WI SCHEDULE

2. FLOOR & REFLECTED R-100 SERIES

CEILING PLANS

3. REPAIR DETAILS R-500 SERIES

NOTES:

1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING

ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS

IN ACCORDANCE WITH THE SPECIFICATIONS. WORK

ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF

DETERIORATION.

REPAIR - FLOOR

REPAIR - OVERHEAD

TRAFFIC TOPPING - RECOAT

EXISTING EXPANSION JOINT

EXISTING FLOOR DRAIN

FD

WORK ITEM LEGEND:

NOTES:

1. NOT ALL WORK ITEMS HAVE DETAILS.

2. SEE SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

X.X.X

WORK ITEM NO

XXX

WORK ITEM NOTE

(SEE ABBREVIATIONS)

CLARIFICATION

DETAIL NO

U P

UP

DN.

UP

DN.

1 2

A

B

B.4

C

3 4 6 7 8 10 11 12 13 13.5 145 9

301'-2"

23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"

3.1

TYP

7.1

95.5.1

11.1

25.3

TYP

6.7

SLAB

16.4

21.13

6.7

COL

11.111.1

16.4

6.1 6.1

6.7

COL

11.2

TYP

7.1

16.5

11.7 6.1

11.1

3.1

3.10

11.2

LEVEL 3

LEVEL 4

LEVEL 5

LEVEL 2

LEVEL 1

LEVEL 6

ISOMETRIC

N

SHEET NOTES

LEGEND

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

PJL

JMK

21-005657.00

LEVEL 2 PLAN

R-102

07/22/2027

OWNERS REVIEW

3/32" = 1'-0"1

LEVEL 2 PLAN

WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES

OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING

IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS

MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR

SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE

ANCHORS CAN NOT BE MORE THAN 1" LONG.

REFERENCES:

1. GENERAL NOTES, LEGEND, AND R-001

WI SCHEDULE

2. FLOOR & REFLECTED R-100 SERIES

CEILING PLANS

3. REPAIR DETAILS R-500 SERIES

NOTES:

1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING

ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS

IN ACCORDANCE WITH THE SPECIFICATIONS. WORK

ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF

DETERIORATION.

REPAIR - FLOOR

REPAIR - OVERHEAD

TRAFFIC TOPPING - RECOAT

EXISTING EXPANSION JOINT

EXISTING FLOOR DRAIN

FD

WORK ITEM LEGEND:

NOTES:

1. NOT ALL WORK ITEMS HAVE DETAILS.

2. SEE SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

X.X.X

WORK ITEM NO

XXX

WORK ITEM NOTE

(SEE ABBREVIATIONS)

CLARIFICATION

DETAIL NO

U P

UP

DN.

DN.

UP

FD

FD

1 2

A

B

B.4

C

3 4 6 7 8 10 11 12 13 13.5 145 9

301'-2"

23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"

7.17.17.1

3.10 3.1

TAR

11.1

3.4

11.1

6.7

COL

6.7

SLAB

6.7

SLAB

11.1

21.13

EXISTING

EXPANSION

JOINT

EXISTING

EXPANSION

JOINT

EXISTING

EXPANSION

JOINT

EXISTING

EXPANSION

JOINT

10.1

EXTERIOR

7.1 7.1

3.4 6.7

COL

11.1

16.5 25.3

6.7

COL

6.1

3.1

TYP

11.1

10.1

3.10

3.1

10.10 7.17.17.1

7.1 7.1

6.1 7.1

7.1 7.1 7.1 7.1

4.1

ABOVE

4.1

ABOVE

11.1

3.1

TAR

6.1

LEVEL 3

LEVEL 4

LEVEL 5

LEVEL 2

LEVEL 1

LEVEL 6

ISOMETRIC

N

SHEET NOTES

LEGEND

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

PJL

JMK

21-005657.00

LEVEL 3 PLAN

R-103

07/22/2027

OWNERS REVIEW

3/32" = 1'-0"1

LEVEL 3 PLAN

REFERENCES:

1. GENERAL NOTES, LEGEND, AND R-001

WI SCHEDULE

2. FLOOR & REFLECTED R-100 SERIES

CEILING PLANS

3. REPAIR DETAILS R-500 SERIES

NOTES:

1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING

ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS

IN ACCORDANCE WITH THE SPECIFICATIONS. WORK

ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF

DETERIORATION.

REPAIR - FLOOR

REPAIR - OVERHEAD

TRAFFIC TOPPING - RECOAT

EXISTING EXPANSION JOINT

EXISTING FLOOR DRAIN

FD

WORK ITEM LEGEND:

NOTES:

1. NOT ALL WORK ITEMS HAVE DETAILS.

2. SEE SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

X.X.X

WORK ITEM NO

XXX

WORK ITEM NOTE

(SEE ABBREVIATIONS)

CLARIFICATION

DETAIL NO

WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES

OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING

IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS

MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR

SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE

ANCHORS CAN NOT BE MORE THAN 1" LONG.

U P

UP

DN.

UP

DN.

D N

U P

UP

DN.

UP

DN.

1 2

A

B

B.4

C

3 4 6 7 8 10 11 12 13 13.5 145 9

301'-2"

23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"

3.1

11.1

11.7

11.7

3.1

7.1

EXTERIOR

TAR

21.13

7.1

7.1

3.1

10.3

11.1

7.1

7.1 11.1

21.13

11.2

3.1

TYP

3.1

6.1

11.7TYP

TYP

11.2

TAR

11.2

TAR

11.7

TYP

16.4

16.4

6.1

11.1

11.1

TAR

6.1

6.1

11.3

11.1

TAR

6.1

21.137.1 6.1 7.1

3.1

3.10

11.1

TAR

3.1

11.7 11.2

3.1

11.1

TAR

11.2

TAR

3.4

11.1

TAR

10.10

3.1

7.1

7.1

3.10

TAR

TAR

3.10

TAR

3.1

TAR

11.1

3.1

TYP

TRAFFIC

BARRIER

3.4 3.7

TAR

LEVEL 3

LEVEL 4

LEVEL 5

LEVEL 2

LEVEL 1

LEVEL 6

ISOMETRIC

N

SHEET NOTES

LEGEND

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

PJL

JMK

21-005657.00

LEVEL 4 PLAN

R-104

07/22/2027

OWNERS REVIEW

3/32" = 1'-0"1

LEVEL 4 PLAN

REFERENCES:

1. GENERAL NOTES, LEGEND, AND R-001

WI SCHEDULE

2. FLOOR & REFLECTED R-100 SERIES

CEILING PLANS

3. REPAIR DETAILS R-500 SERIES

NOTES:

1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING

ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS

IN ACCORDANCE WITH THE SPECIFICATIONS. WORK

ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF

DETERIORATION.

REPAIR - FLOOR

REPAIR - OVERHEAD

TRAFFIC TOPPING - RECOAT

EXISTING EXPANSION JOINT

EXISTING FLOOR DRAIN

FD

WORK ITEM LEGEND:

NOTES:

1. NOT ALL WORK ITEMS HAVE DETAILS.

2. SEE SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

X.X.X

WORK ITEM NO

XXX

WORK ITEM NOTE

(SEE ABBREVIATIONS)

CLARIFICATION

DETAIL NO

WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES

OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING

IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS

MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR

SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE

ANCHORS CAN NOT BE MORE THAN 1" LONG.

U P

DN.

DN.

1 2

A

B

B.4

C

3 4 6 7 8 10 11 12 13 13.5 145 9

301'-2"

23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"

74.11

TAR

3.10

11.7

11.2

11.7 11.2

11.7

11.1

TYP

11.711.2

3.1

10.10

11.1

45.6

6.1

21.13

11.7

74.11

3.1

6.1 11.16.1

11.7

11.7

11.211.1

16.5

74.11

11.7

TAR

11.1

16.5 11.711.7 3.4

11.1

11.2

11.2

11.211.1

11.1

11.1

11.7

3.1

11.7

11.1

6.1

7.1

21.13

11.111.7 21.13

11.7

11.2

TYP

11.1

3.1 11.7

11.2 11.1

4.1

ABOVE

5.1

ABOVE

3.1

TAR

TAR

LEVEL 3

LEVEL 4

LEVEL 5

LEVEL 2

LEVEL 1

LEVEL 6

ISOMETRIC

N

SHEET NOTES

LEGEND

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

PJL

JMK

21-005657.00

LEVEL 5 PLAN

R-105

07/22/2027

OWNERS REVIEW

3/32" = 1'-0"1

LEVEL 5 PLAN

REFERENCES:

1. GENERAL NOTES, LEGEND, AND R-001

WI SCHEDULE

2. FLOOR & REFLECTED R-100 SERIES

CEILING PLANS

3. REPAIR DETAILS R-500 SERIES

NOTES:

1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING

ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS

IN ACCORDANCE WITH THE SPECIFICATIONS. WORK

ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF

DETERIORATION.

REPAIR - FLOOR

REPAIR - OVERHEAD

TRAFFIC TOPPING - RECOAT

EXISTING EXPANSION JOINT

EXISTING FLOOR DRAIN

FD

WORK ITEM LEGEND:

NOTES:

1. NOT ALL WORK ITEMS HAVE DETAILS.

2. SEE SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

X.X.X

WORK ITEM NO

XXX

WORK ITEM NOTE

(SEE ABBREVIATIONS)

CLARIFICATION

DETAIL NO

WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES

OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING

IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS

MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR

SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE

ANCHORS CAN NOT BE MORE THAN 1" LONG.

U P

1 2

A

B

B.4

C

3 4 6 7 8 10 11 12 13 13.5 145 9

301'-2"

23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 23'-2" 11'-4" 11'-10"

3.4

74.11

TAR

3.4

7.1

74.11

TAR

11.7

3.4

3.1

11.7

3.1

11.7

16.4

TYP

11.7

11.7

6.111.711.7

3.1

3.1

3.1

3.4

11.7 16.5

3.1

3.4 11.7

6.1

6.1

74.11

74.11

11.7

84.1

11.7

3.4

74.11

@ WASH,

TYP

TYP

3.1

@ WASH,

TYP

LEVEL 3

LEVEL 4

LEVEL 5

LEVEL 2

LEVEL 1

LEVEL 6

ISOMETRIC

N

SHEET NOTES

LEGEND

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

PJL

JMK

21-005657.00

LEVEL 6 PLAN

R-106

07/22/2027

OWNERS REVIEW

3/32" = 1'-0"1

LEVEL 6 PLAN

REFERENCES:

1. GENERAL NOTES, LEGEND, AND R-001

WI SCHEDULE

2. FLOOR & REFLECTED R-100 SERIES

CEILING PLANS

3. REPAIR DETAILS R-500 SERIES

NOTES:

1. CONTRACTOR IS RESPONSIBLE FOR DETERMINING

ACTUAL EXTENT AND LOCATIONS OF REPAIR AREAS

IN ACCORDANCE WITH THE SPECIFICATIONS. WORK

ITEM IS SHOWN ONLY TO REPRESENT THE TYPES OF

DETERIORATION.

REPAIR - FLOOR

REPAIR - OVERHEAD

TRAFFIC TOPPING - RECOAT

EXISTING EXPANSION JOINT

EXISTING FLOOR DRAIN

FD

WORK ITEM LEGEND:

NOTES:

1. NOT ALL WORK ITEMS HAVE DETAILS.

2. SEE SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

X.X.X

WORK ITEM NO

XXX

WORK ITEM NOTE

(SEE ABBREVIATIONS)

CLARIFICATION

DETAIL NO

WARNING: THE FLOOR SLAB HAS POST-TENSIONING TENDONS NEAR BOTH SURFACES

OF THE SLAB. THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN WORKING

IN THE SLAB SO AS NOT TO DAMAGE THE TENDONS OR TENDON SHEATHING. TENDONS

MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. NO ANCHORS MAY BE DRILLED OR

SHOT INTO THE SLAB WITHOUT FIRST LOCATING THE TENDONS AND THEN THE

ANCHORS CAN NOT BE MORE THAN 1" LONG.

SPALL OR DELAMINATION

REMOVE CONCRETE

WITHIN SECTION SHOWN

EXISTING PT TENDON,

DEPTH VARIES

REINFORCEMENT (TYP),

LOCATIONS APPROXIMATE.

CLEAN AND APPLY CORROSION

INHIBITOR TO ALL EXPOSED

REINFORCEMENT. PROVIDE 3/4"

CLEARANCE AROUND ALL

EXPOSED REINFORCEMENT

EXISTING CONCRETE

SLAB

ORIGINAL SURFACE

SAWCUT PATCH

PERIMETER 1/2" (TYP)

VARIES

-4

CAUTION: EMBEDDED CONDUIT, PIPING OR POST-TENSIONING STRAND

CONTAIN DANGEROUS STORED ENERGY. CONFIRM LOCATIONS AND

CONDITION PRIOR TO DEMOLITION.

INSTALL LATEX MODIFIED

CONCRETE OR PREPACKAGED

REPAIR MATERIAL

VARIES

EXIST FLOOR SLAB

REMOVE CONCRETE WITHIN

SECTION SHOWN. PROVIDE RADIUS

AND SLOPE TO MATCH EXISTING.

SAWCUT PATCH

PERIMETER 3/4" (TYP)

REINFORCEMENT (TYP),

LOCATIONS APPROXIMATE.

CLEAN AND APPLY CORROSION

INHIBITOR TO ALL EXPOSED

REINF. PROVIDE 3/4" CLEARANCE

AROUND ALL EXPOSED REINF

WHERE REQ'D AS SPECIFIED IN

SECTION "SURFACE

PREPARATION FOR PATCHING".

REPAIR

CONCRETE SEE WI

3.0

REMOVE CONCRETE WITHIN

SECTION SHOWN

EXIST

CONCRETE

SLAB

WI 11.2, TYP AT ALL

PERIMETER

SAW CUT

PERIMETER TYP

REMOVE EXISTING SLAB 3/4" MIN. DEEP AT LATEX

CONCRETE OVERLAY AREAS AS SPECIFIED IN

SECTION "SURFACE PREPARATION FOR PATCHING"

ORIGINAL SURFACECAUTION: EMBEDDED CONDUIT, PIPING

OR POST-TENSIONING STRAND CONTAIN

DANGEROUS STORED ENERGY. CONFIRM

LOCATIONS AND CONDITION PRIOR TO

DEMOLITION.

/4

SPALL OR

DELAMINATION

EXISTING

CONSTRUCTION JOINT

REMOVE CONCRETE WITHIN

SHADED SECTION SHOWN

CONC SLAB ON GRADE

ORIGINAL SURFACE

SAWCUT PATCH

PERIMETER 3/4" (TYP)

COMPACTED CLASS

5, AS REQUIRED

ADDED REINFORCEMENT /

WWR, REFER TO

SPECIFICATIONS

INSTALL AND SEAL

CONSTRUCTION JOINT TO

MATCH EXISTING, SEE

WORK ITEM 11.2

VARIES

REINFORCEMENT (TYP), LOCATIONS

APPROXIMATE. CLEAN AND APPLY

CORROSION INHIBITOR TO ALL

EXPOSED REINF. PROVIDE 3/4"

CLEARANCE AROUND ALL EXPOSED

REINF. WHERE REQ'D AS SPECIFIED IN

SECTION "SURFACE PREPARATION

FOR PATCHING".

VARIES

SPALL OR

DELAMINATION

REINFORCEMENT (TYP),

LOCATIONS APPROXIMATE. CLEAN

AND APPLY CORROSION

INHIBITOR TO ALL EXPOSED

REINF. PROVIDE 3/4" CLEARANCE

AROUND ALL EXPOSED REINF

WHERE REQ'D AS SPECIFIED IN

SECTION "SURFACE PREPARATION

FOR PATCHING".

GRIND OR SAWCUT

PATCH PERIMETER

1/2" (TYP)

REMOVAL LIMITS

EXIST CONCRETE SLAB

ORIGINAL

SURFACE

REMOVE CONCRETE WITHIN

SECTION SHOWN. ROUGHEN

TO ICRI CSP 7 TO 9.

2"-4"

V A

R

IE

S

REMOVE CONCRETE

WITHIN SECTIONS

SHOWN SHADED, TYP.

ROUGHEN SURFACE

TO ICRI CSP 7 TO 9

VARIES

VARIES

2"-4"

V A

R

IE

S

SPALL OR

DELAMINATION, TYP

REMOVAL

LIMITS, TYP

GRIND OR SAWCUT

PATCH PERIMETER

1/2", TYP

REINFORCEMENT, TYP.

LOCATIONS APPROXIMATE CLEAN

AND APPLY CORROSION

INHIBITOR TO ALL EXPOSED

REINF. PROVIDE 3/4" CLEARANCE

AROUND ALL EXPOSED REINF

WHERE REQ'D AS SPECIFIED IN

SECTION "SURFACE

PREPARATION FOR PATCHING".

P A

Y U

N

IT

P A

Y U

N

IT

P A

Y U

N

IT

DEPTH OF REMOVAL

FOR THIS WORK ITEM.

SETTING UP PAY UNITS

THIS WAY ELIMINATES

DOUBLE PAY FOR

CORNERS TYP FOR

BEAMS AND COLUMNS

CAUTION, LONGITUDINAL

REINF MAY BE

PRESTRESSED AND

CONTAIN DANGEROUS

STORED ENERGY.CONFIRM

BEFORE REMOVAL

PAY UNIT

REMOVAL LIMITSGRIND OR SAWCUT

PATCH PERIMETER

3/4" (TYP)

REMOVE CONCRETE

WITHIN SECTION

SHOWN SHADED

(TYP) ROUGHEN

SURFACE TO

ICRI CSP 7 TO 9, TYP

REINFORCEMENT (TYP),

LOCATIONS APPROXIMATE.

CLEAN AND APPLY CORROSION

INHIBITOR TO ALL EXPOSED

REINF. PROVIDE 3/4"

CLEARANCE AROUND ALL

EXPOSED REINF WHERE REQ'D

AS SPECIFIED IN SECTION

"SURFACE PREPARATION FOR

PATCHING".

SPALL OR

DELAMINATION

(TYP)

REPAIR CONCRETE

NOTES:

1. COLUMN TIES WHICH HAVE LOST MORE THAN 15% OF ORIGINAL CROSS

SECTIONAL AREA SHALL BE SUPPLEMENTED AS ENGINEER DIRECTS.

2. NUMBER AND LOCATION OF REINFORCEMENT SHOWN MAY DIFFER FROM

ACTUAL FIELD CONDITIONS.

2"-4"2"-4"

V A

R

IE

S

V A

R

IE

S

EXIST PT

ANCHORS, ACTUAL

DEPTH AND

LOCATION VARIES.

CLEAN AND COAT

WITH A RUST

INHIBITING COATING

DETERIORATED CONC

REMOVAL AND

REPLACEMENT

AREA

SAWCUT PERIMETER 3/4",

ROUGHEN SURFACE TO CSP 7 TO 9

PRIOR TO GROUT PLACEMENT.

REPLACE MORTAR TO ITS

ORIGINAL DIMENSION AND

SURFACE FINISH

PT CONC SLAB

OR BEAM

PT CONC

COLUMN

2" - 4"

V A

R

IE

S

EXIST FACE OF WALL

SPALL OR DELAMINATION

REINFORCEMENT (TYP),

LOCATIONS APPROXIMATE.

CLEAN AND APPLY

CORROSION INHIBITOR TO ALL

EXPOSED REINF. PROVIDE 3/4"

CLEARANCE AROUND ALL

EXPOSED REINF WHERE

REQ'D AS SPECIFIED IN

SECTION "SURFACE

PREPARATION FOR

PATCHING".

GRIND OR SAWCUT PATCH

ROUGHEN SURFACE TO ICRI

CSP 7 TO 9, TYP

TROWEL APPLIED

MORTAR. SEE NOTE 1

INSTALL PATCH

FLUSH WITH WALL

NOTE:

1. FOR WALL PANELS WITH ARCHITECTURAL FINISHES REFER TO WORK ITEM SPECIFICATIONS 91.4.

4" SAW CUT STAIR

ENTIRE WIDTH

CONCRETE REPAIR MORTAR

(SEE SPECIFICATIONS)

R 1/2"

EXISTING CAVITY

SURFACE

TRAFFIC

TOPPING ON

RISE, RUN &

SIDES OF STAIRS

(WI 16.1)

SAW CUT STAIR

ENTIRE WIDTH

3/ 4"

3" M

IN

1/2"

/2

NOTES:

1. REMOVE EXISTING CAST IRON NOSING AND ANCHOR DEVICES.

2. REMOVE AND REPLACE ALL SOUND AND UNSOUND CONCRETE

WITHIN SECTION SHOWN CROSS HATCHED.

#3 EPOXY COATED

SET IN EPOXY

ALUMINUM NOSING

EQUAL TO

"STAIRMASTER"

TYPE 540, TYP

3'-0"

#3

REPAIR NOTES:

1. DIMENSION VARIES.

2. REPAIR VOIDS / CHIPS.

3. REMOVE HIGH SPOTS.

4. REPAIR SPALLED EDGES.

5. REMOVE OVERHANGS.

6. REMOVE SLOPE ON SURFACE.

7. PROVIDE SURFACES TO BE LEVEL / PLUMB.

#6

#5

#6

#7#2

#4

CONCRETE SUBSTRATE

EXPANSION JOINT

BLOCKOUT AND

PROFILE

SEE DETAIL WI 10.3

CAUTION: EMBEDDED CONDUIT, PIPING OR

POST-TENSIONING STRAND CONTAIN

DANGEROUS STORED ENERGY. CONFIRM

LOCATIONS AND CONDITON PRIOR TO

DEMOLITION.

#1

8. WORK SHOWN HERE IS INCIDENTAL TO W.I. SERIES 10.0.

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

AM

JMK

21-005657.00

REPAIR DETAILS

R-501

07/22/2027

OWNERS REVIEW

3.1

FLOOR REPAIR - PARTIAL DEPTH/SHALLOW

3.4

FLOOR REPAIR - CURBS / WALKS

3.7

FLOOR REPAIR - CONCRETE WASHES

3.11

FLOOR REPAIR- SLAB-ON-GRADE

4.1

CEILING REPAIR - PARTIAL DEPTH/SHALLOW

5.1

BEAM REPAIR - PARTIAL DEPTH/SHALLOW

6.1

COLUMN REPAIR - PARTIAL DEPTH/SHALLOW

6.7

COLUMN/SLAB REPAIR - GROUT PLUG

7.1

WALL REPAIR - PARTIAL DEPTH/SHALLOW

3.10

FLOOR REPAIR - STEEL STAIR NOSING REPAIR

REVISIONS

MARK DATE DESCRIPTION

9.1.1

EXPANSION JOINT PREPARATION- TYPICAL BLOCKOUT REPAIRS

(FOR REFERENCE)

EXISTING CONCRETE

ELASTOMERIC CONCRETE

HEADER, TYP

WBA W/ ME MEMBRANE

GLAND OR ENGINEER

APPROVED EQUAL

TYP

3 1/2" MIN

TYP

2 1/2" MIN

/4

FLOOR TO FLOOR

NOTE:

1. CONTRACTOR SHALL, WITH MANUFACTURER, VERIFY FIELD INSTALLATION WIDTH

BASED ON TEMPERATURE CONDITIONS.

2. PROVIDE SHOP DRAWINGS SHOWING JOINT INTERSECTIONS AND WALL TERMINATIONS.

VIF

REPAIR EXPANSION JOINT

BLOCKOUT AS REQUIRED.

REFER TO DETAIL 9.1.1

EXISTING CONCRETE

ELASTOMERIC CONCRETE

HEADER, TYP

REPAIR NOSING PER

MANUFACTURERS REQUIREMENTS

EXISTING WING-TYPE

GLAND SYSTEM

FIELD VERIFY

V

IF

NOTES:

1. PAYMENT IS BASED ON ONE SIDE OF JOINT ONLY.

/4

EXISTING CRACK. CENTER

ROUTED GROOVE ON CRACK

ROUT CRACK WITH 'V' BLADE

AND FILL W/ FLEXIBLE SEALANT.

INSTALL SEALANT 1/16" BELOW

ADJACENT SURFACES, OR

FLUSH W/ ADJACENT SURFACES

TO RECEIVE TRAFFIC COATING.

DO NOT OVERFILL JOINT.

EXIST CONCRETE

EXISTING CONCRETE

EXISTING CRACK

REMOVE ALL EXISTING SEALANT,

PREPARE SUBSTRATE, AND FILL

W/FLEXIBLE SEALANT. INSTALL

SEALANT FLUSH W/ SURFACE.

DO NOT OVERFILL JOINT.

BOND BREAKER TO SEPARATE

SEALANT FROM CONCRETE AT

BOTTOM OF JOINT

1/2"

3/8"

/1

/2

EXIST SUBSTRATE

NOTES:

1. CLEAN JOINT SUBSTRATE BY SAND & AIR BLASTING.

2. PREPARE AND PRIME SEALANT CAVITY & INSTALL SEALANT ACCORDING TO

SEALANT MANUFACTURER'S RECOMMENDATIONS.

SEALANT

BACKER ROD

3/4" ±

THROAT DEPTH 1/2

JOINT WIDTH

SEALANT MATERIAL,

SEE NOTE 1.

EXIST FINISHED

FLOOR SURFACE

EXIST VERTICAL

SURFACE

NOTES:

1. REMOVE ALL EXISTING COVE SEALANT MATERIAL IF PRESENT. PREPARE

SURFACE PER SPECIFICATIONS.

2. A PRIMER COAT IS REQUIRED FOR ALL SYSTEMS.

1/ 2"

3/4"

/4

HORIZ / VERT

TRANSITION

COVE SEALANT

SEE DETAIL 11.7

LIMITS OF SURFACE

PREPARATION

VERTICAL SURFACE

(WALL OR COLUMNS)

CONTRACTOR TO PROVIDE

STRAIGHT FINISHED LINE

CRACKS < 1/32"

ISOMETRIC

PROVIDE 4" WIDE DETAIL

COAT CENTERED OVER

ALL CRACKS LESS THAN

1/32" WIDE

CRACKS > 1/32"

(OR MOVING CRACKS)

ROUT AND SEAL CRACKS GREATER

THAN 1/32" WIDTH. REMOVE AND

REPLACE ALL EXIST CRACK/JOINT

SEALANT. SEE DETAILS 11.1 OR 11.2.

PROVIDE 4" WIDE DETAIL COAT

CENTERED OVER CRACK

TRAFFIC TOPPING (FLOOR

SURFACE OR CURB)

NOTE:

1. QUANTITIES BASED ON HORIZONTAL APPLICATION AREA. VERTICAL DETAILING, ADDITIONAL

DETAIL COAT OVER CRACKS, ROUTING AND SEALING CRACKS, INSTALLATION OF COVE SEALANT, AND REMOVAL AND REPLACEMENT OF EXISTING SEALANTS ARE INCIDENTAL TO THIS WORK.

REPLACE

PRE-MOLDED JOINT

MAINTAIN 1/2"

SEPERATION FOR JOINT

AT PERIMETER

KEEP EXIST ADHESIVE

JOINT

INSTALL WEDGES &

POWER SEAT WEDGES

TO CABLE 80% MUTSSTEP 1 - SEAT DEAD END (FIRST BACK STRESS)

JACK AGAINST

COLUMN OR

SPLICE COUPLER

INSTALL WEDGES STRESS

CABLE TO SPECIFIED FORCE

STRESSING FORCE IS 3

KIPS INCLUDING WEDGE

SEATING LOSSES

STEP 3 - SEAT LIVE END (SECOND BACKSTRESSING)

STEP 2 - TENSION CABLE

POWER SEAT

INSTALLED WEDGES

TO 80% MUTS

EXISTING

ANCHOR, REUSE

IF APPLICABLE

EXISTING

ANCHOR, REUSE

IF APPLICABLE

JACK AGAINST

COLUMN OR

SPLICE COUPLER

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

PJL

JMK

21-005657.00

REPAIR DETAILS

R-502

07/22/2027

OWNERS REVIEW

10.3

EXPANSION JOINT - ELASTOMERIC CONCRETE EDGED

10.10

EXPANSION JOINT - HEADER REPAIR

11.1

SEAL CRACKS AND JOINTS

11.2

REPAIR CRACK/JOINT SEALANT

11.3

VERTICAL JOINT SEALANT

11.7

COVE SEALANT

16.4

TRAFFIC TOPPING - RECOAT (PARTIAL SYSTEM)

16.5

TRAFFIC TOPPING - RECOAT (COMPLETE SYSTEM)

10.1

EXPANSION JOINT - PREMOLDED (FLOOR TO FLOOR)

16.5

TRAFFIC TOPPING - VEHICULAR

REVISIONS

MARK DATE DESCRIPTION

21.13

REPLACE BARRIER CABLE

CONCRETE SLAB

INSTALL

CLEAN-OUTCONNECT TO EXISTING DRAIN LINE.

HOLD AS HIGH AS POSSIBLE.

MAINTAIN 1/8" PER FT MINIMUM PITCH.

HANGERS WITH .75 IN

MIN ROD DIA @ 5'-0" OC

MAX PER WI 25.3

NEW 6" PIPE (4"

PIPE AT COVERED

LEVELS)

NOTES:

1. USE SERVICE WEIGHT CAST IRON PIPE. ALL MATERIALS SHALL BE IN ACCORDANCE WITH

PREVAILING BUILDING ORDINANCES.

2. INSTALL ADJUSTABLE HANGERS AS REQUIRED, VERIFY MINIMUM HEIGHT RESTRICTIONS OF

PREVAILING BUILDING ORDINANCES PRIOR TO INSTALLATION.

W I

.3

EXIST

SUBSTRATE

NOTES:

1. CLEAN JOINT SUBSTRATE BY SAND & AIR BLASTING.

2. PREPARE AND PRIME SEALANT CAVITY & INSTALL SEALANT ACCORDING TO SEALANT

MANUFACTURER'S RECOMMENDATIONS.

3. CONTRACTOR SHALL, WITH MANUFACTURER, VERIFY FIELD INSTALLATION WIDTH

BASED ON TEMPERATURE CONDITIONS. TOTAL ANTICIPATED JOINT MOVEMENT -

COORDINATE JOINT MOVEMENT WITH ENGINEER

VIF

VARIES

EXIST

SUBSTRATE

FIELD-APPLIED SILICONE

CORNER BEADS AND SILICONE

BAND FORCED DOWN ALONG

SIDE OF JOINT AS SHOWN-BOTH

SIDES

FIELD APPLIED SEALANT

CONTINUOUS BOTH SIDES

PREFORMED ELASTOMERIC

SEAL, RECESSED

ADHESIVE

BOTH SIDES

74.11

APPLY BASE COAT & MESH

REINFORCING TO PATCH

AREA AND OVERLAP

EXISTING MESH 3"

REMOVE DAMAGED

EIFS FULL DEPTH TO

SUBSTRATE

SQUARE CUT

REPAIR AREA

CUT NEW INSULATION

REPLACEMENT PLUG TO

FIT SNUG. FIX IN PLACE

WITH EIFS ADHESIVE OR

MECHANICAL FASTENER

INSTALL FINISH COAT

OVER REPAIR AREA -

MATCH FINISH &

TEXTURE OF

SURROUNDING AREA

FINISH COAT REMOVED

AND INTACT BASE

COAT AND MESH

EXPOSED

EDGE OF FINISH COAT

(SHARP EDGE) MASK

SURROUNDING WALL

AREA

EXISTING

UNDAMAGED EIFS

REPAIRPREPARATION WORK

T Y

P

CHECKED BY:

SHEET TITLE:

DRAWN BY:

PROJECT NO:

COPYRIGHT © 2026. ALL RIGHTS RESERVED. NO

PART OF THIS DOCUMENT MAY BE REPRODUCED

IN ANY FORM OR BY ANY MEANS WITHOUT

PERMISSION FROM WALKER CONSULTANTS.

7760 France Ave S, Suite 820 Minneapolis, MN 55435

952.595.9116 Ph

www.walkerconsultants.com

ISSUE DATE:

ISSUE:

I hereby certify that these drawings were prepared by me or under my supervision and that I am a duly licensed Professional Engineer under the laws of the State of Minnesota.

/8

/2

:5

:3

A

M A u to d e s k D o c s /2

-0

.0

M

N R e s to

P ro je c ts

R e v it

.0

.0

M

C C

R

.r v t

1403 3RD AVE S

MINNEAPOLIS, MN 55404

CONVENTION CENTER

P R

E L

IM

IN

A R

Y

D O

N O

T U

S E

F O

R C

O N

S T

R U

C T

IO

N

PARKING FACILITY REPAIRS

PJL

JMK

21-005657.00

REPAIR DETAILS

R-503

07/22/2027

OWNERS REVIEW

25.3

MECHANICAL - PIPE AND HANGERS

74.11

INSTALL PREFORMED JOINT SEALANT

84.1

REPAIR EXISTING EIFS CLADDING

File details come from the government source that posted it. Updated .