About this file
This is a site diagram and product specification document for a Fence-Gate Installation project located in Ripley, Tennessee, associated with a military facility. The diagram illustrates the proposed layout of a security gate system including a powered chain link cantilever gate on the main west side entrance (125 feet in length) and a secondary service gate (54 feet). The site plan depicts utility locations including overhead power lines, buried power infrastructure, water supply from the city to a wash rack, a mechanical room, septic tank, and sewer line connections. Key measurements indicate property dimensions of 168 feet, 110 feet, 112 feet, and 136 feet across various sections, with specific distances noted for gate placements and service access points. The document references DA02M33 specifications and identifies a Hy Security SlideDriver 15 system as the proposed gate mechanism.
The diagram serves as a technical reference for bidders to understand site constraints, existing infrastructure, and installation requirements for the fencing and gate system. The specifications referenced in the document indicate the use of commercial-grade security gate components suitable for a military installation. Prospective bidders should review the site plan in conjunction with the related scope of work documentation to understand all project requirements, material specifications, installation locations, utility coordination needs, and any site-specific considerations necessary for accurate proposal submission.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Fence_-_Gate_Installation_-_Ripley_-_Military.pdf | ||
| Event_13871_-_Terms_-_Ripley.pdf | ||
| Ripley_RC_Fence_scope.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5/14/25, 12:47 PM Untitled project - Google Earth https://earth.google.com/web/@35.72097449,-89.56434655,122.30705631a,306.10507138d,35y,0h,0t,0r/data=CgRCAggBMikKJwolCiExMWp6YUNF… 1/1
Septic tank
Sewer line
Overhead Power Lines
Overhead Power Lines
Burried Power
Water to wash rack
Mech Room
Water from City
168'
110' 33'
136'
266' 28'
24' Chain link cantilever gate 24' Powered Main Chainlink, West Side
125'
26'
112'
54'
10' service gate
DA02M33
Line
DA02M33
Line
DA02M33
Line
DA02M33
Line
DA02M33
Line
DA02M33
Line
DA02M33
Line da02m33 Rectangle da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Line da02m33 Rectangle