ESBD_File_356081_RFCSP 24-016C Construction Documents.pdf
PDF 36 MB Posted
- Solicitation number
- 24-016C
- Issued by
- Guadalupe County, Santa Anna Town, Texas
About this file
The document is an RFCSP (Request for Competitive Sealed Proposal) for the Samuel Clemens High School Serving Line Renovation project, issued by the Schertz-Cibolo-Universal City Independent School District (SCUCISD) located in Schertz, Texas. The project involves the replacement of the Food Service serving line, installation of Overhead Security Grilles, and new gypsum board on metal stud assemblies in the Samuel Clemens High School Cafeteria. A non-mandatory pre-proposal conference is scheduled for April 24, 2024, and site visits can be arranged through the District's representative, AGCM. Proposals are due by 2:00 PM on May 9, 2024, and the bid opening will take place immediately following the deadline.
The RFCSP specifies that the District will evaluate and either accept or reject the proposals based on the stated criteria. Consistent with Texas Government Code 552.104, the proposals will not be public information until a recommendation has been made to and accepted by the District's Board of Trustees. The District reserves the right to accept or reject any or all proposals in the best interest of the District and to waive any formalities or irregularities in the RFCSP process.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ESBD_File_356081_RFCSP 24-016C Bid Notice.pdf | ||
| ESBD_File_356081_RFCSP 24-016C.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4040 BROADWAY STREET, SUITE 300
SAN ANTONIO, TEXAS 78209
Architecture - Engineering - Interiors
1060 ELBEL ROAD ,
SCHERTZ , TEXAS 78154
SCHERTZ CIBOLO UNIVERSAL CITY
INDEPENDENT SCHOOL DISTRICT
Foodservice Consultant 13061 #3 Highway 181 , SAN ANTONIO , TEXAS 78223
COSPER & ASSOCIATES, INC.
Structural Engineer
1045 CENTRAL PARKWAY NORTH, SUITE 200 ,
SAN ANTONIO , TEXAS 78232
INTELLIGENT ENGINEERING SERVICES
Technology/Security Consultant
18200 W INTERSTATE 10, SUITE 103 ,
SAN ANTONIO , TEXAS 78230
COMBS CONSULTING GROUP
Revisions:
A u st in
S a n A n to n io
H o u s to n
B a rt o n S p ri n g s R o a d S u it e A u st in Te xa s
B ro a d w a y S u it e S a n A n to n io Te xa s
F a n in S tr e e t, S u it e H o u st o n Te xa s p .4 .7 f .4 .7 p .2 .6 f .2 .6 p .4 .1 f .4 .1
C R e v it P ro je c ts
\1
S
C U
C
IS
D C le m e n s H
S C a fe te ri a
S e rv in g S n a c k B a r_ a rc h c e n tr a l_ jm o o re C
M
J N
.r v t
/1
/2
:3
:4
A
M
C L
E M
E N
S H
S C
A F
E T
E R
IA
S
E R
V
IN
G L
IN
E
R E
N O
V A
T
IO
N E
LB
E L R O A D S C H E R
TZ
TE
X A S
S C U C I N D E P E N D E N T S C H O O L D
IS
TR
IC
T
CLEMENS HS CAFETERIA SERVING LINE RENOVATION
1001 ELBEL ROAD, SCHERTZ, TEXAS 78154
04/11/2024
CONTRACT DOCUMENTS
Mission: We believe every project has a mission and strive to design environments that have a purpose that extends far beyond form and function.
04/11/2024
Project No. 1403.18
CONTRACT DOCUMENTS
COVER SHEET
G1.0
O 'C O N N E
LL
R O B E R
TS
O N
IN
C
O 'C O N N E
LL
R O B E R
TS
O N
IN
C
BUILDING CODES:
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL EXISTING BUILDING CODE
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL FUEL GAS CODE
2023 NATIONAL ELECTRIC CODE
2015 INTERNATIONAL ENERGY CODE
2018 INTERNATIONAL PLUMBING CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PROPERTY MAINTENANCE CODE
2009 MANUAL OF CROSS CONNECTION CODE, TENTH
EDITION
2012 TEXAS ACCESSIBLE STANDARDS
EXISTING BUILDING:
CONSTRUCTION TYPE: II-B
OCCUPANCY TYPE OF AFFECTED AREA:
A2 - ASSEMBLY (CAFETERIA)
FULLY SPRINKLERED
NOT CHANGING OCCUPANCY TYPE/USE OR EXISTING
EGRESS
VICINITY MAP
SITE MAP
SITE
LOCATION
FACILITY
SCOPE
DRAWING INDEX
GENERAL
G2.1 ADULT TAS ACCESSIBILITY
G1.0 COVER SHEET
STRUCTURAL
S0.1 STRUCTURAL NOTES
S0.2 SPECIAL INSPECTIONS
S1.1 SNACK BAR FRAMING PLANS
S2.1 CAFETERIA SERVING AREA FRAMING PLANS
S3.1 SECTIONS AND DETAILS
S3.2 ELEVATIONS
ARCHITECTURAL
A0.1 SYMBOLS,ABBREVIATIONS & TYPICAL LAYOUTS
A2.0 COMPOSITE DEMOLITION PLAN
A2.1 ENLARGED DEMOLITION PLAN
A3.1 ENLARGED DINING FLOOR PLAN
A4.3 BUILDING SECTIONS
A7.7 PARITITON TYPES, DOOR AND FRAME TYPES
A9.1 REFLECTED CEILING PLAN
A10.1 ROOM FINISH PLAN
A11.1 INTERIOR ELEVATIONS
A13.1 FURNITURE PLAN
PLUMBING
P1.1 PLUMBING NOTES, SYMBOLS AND ABBREVIATIONS
P2.1 PLUMBING UNDERFLOOR DEMOLITION PLAN
P2.2 PLUMBING DEMOLITION PLAN
P3.1 PLUMBING UNDERFLOOR PLAN
P3.2 PLUMBING PLAN
P4.1 PLUMBING ENLARGED PLANS
P7.1 PLUMBING DETAILS
ELECTRICAL
E1.1 ELECTRICAL NOTES, SYMBOLS AND ABBREVIATIONS
E2.1 ELECTRICAL DEMOLITION PLAN
E3.1 ELECTRICAL POWER PLAN
E4.1 LIGHTING PLAN
E7.1 ELECTRICAL ONE-LINE DIAGRAM
E8.1 ELECTRICAL SCHEDULES
E9.1 ELECTRICAL DETAILS
TECHNOLOGY
T000 TECHNOLOGY SYMBOLS AND LEGENDS
TD200 TECHNOLOGY LEVEL 1 COMPOSITE DEMO FLOOR PLAN
TD201 TECHNOLOGY LEVEL 1 ENLARGED DEMO FLOOR PLAN
T200 TECHNOLOGY LEVEL 1 COMPOSITE FLOOR PLAN
T201 TECHNOLOGY LEVEL 1 ENLARGED FLOOR PLAN
T400 TECHNOLOGYTYPICAL DETAILS
TS000 SECURITY SYMBOLS & LEGENDS
TSD200 SECURITY LEVEL 1 COMPOSITE DEMO FLOOR PLAN
TSD201 SECURITY LEVEL 1 ENLARGED DEMO FLOOR PLAN
TS200 SECURITY LEVEL 1 COMPOSITE FLOOR PLAN
TS201 SECURITY LEVEL 1 ENLARGED FLOOR PLAN
TS400 SECURITY TYPICAL DETAILS
FOOD SERVICE
FS1.1 KITCHEN EQUIPMENT FLOOR PLAN
FS2.1 KITCHEN EQUIPMENT LISTING
FS3.1 KITCHEN PLUMBING ROUGH-IN PLAN
FS4.1 KITCHEN ELECTRICAL ROUGH-IN PLAN
FS5.1 MAIN SERVING COUNTER DETAILS
FS5.2 MAIN SERVING COUNTER DETAILS
FS5.3 MAIN SERVING COUNTER DETAILS
FS5.4 SNACK BAR SERVING COUNTER DETAILS
FS5.5 SNACK BAR SERVING COUNTER DETAILS
FS5.6 SNACK BAR SERVING COUNTER DETAILS
NO. DESCRIPTION DATENO. DESCRIPTION DATE
TABS-2024015803
CSP #24-016C
04/11/2024
THERMOSTAT
SWITCH8
M
IN
1'-3"
M A
X
4"-6"
OVERHEAD
CLEARANCE
REF. SECTION 307
TYP SWITCH/
THERMOSTAT/STROBE
/LOCATION
REF. SECTION 309
ELEVATION
LOBBY
CLEAR
OPENING
DOOR NOTES:
1. DOOR THRESHOLDS: THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 3/4" IN HEIGHT FOR EXTERIOR SLIDING DOORS OR 1/2" FOR OTHER TYPES OF DOORS.
THRESHOLDS AND FLOOR LEVEL CHANGES BETWEEN 1/4" AND 1/2" AT ACCESSIBLE DOORWAYS SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2.
PUSH SIDE
PULL SIDE
W C
L O
S E
R
PUSH SIDE
PULL SIDE
W/ LATCH
& CLOSER
"M
IN
I F
P A
R A
L L E
L
T O
D O
O R
I S
M
IN
W
C L O
S E
R
L A
T C
H
PUSH SIDE
PULL SIDE
W C
L O
S E
R
3'-0" MIN.
PARALLEL TO DOOR
4'-0" MIN.
4'-0" MIN.
3'-6"
3'-6"
2'-8" CLEAR MIN.
2'-8" MIN.
18" MIN.
M
IN
M
IN
12" MIN.
4" U.N.O.
M
IN
M
IN
24" MIN.
3'-6"
" M
IN
M
IN
M
A X
M
IN
32" MIN.
24" MIN.
24" MIN.
DOORS
REF. SECTION 404 DOORS
SWINGING DOOR CLEARANCES
(LATCH SIDE APPROACH)
SWINGING DOOR CLEARANCES
(HINGE SIDE APPROACH)
SWINGING DOOR CLEARANCES
(FRONT APPROACH)
CLEAR DOORWAY WIDTH
CLEAR DOORWAY DEPTH
TWO HINGED DOORS IN SERIES
POCKET DOOR CLEARANCES
SIDE APPROACH
PLANPLAN
PLANPLAN
PLAN
4'-0" MIN.
M
IN
M
IN
60" MIN.
12" MIN.
36" MIN.
12" MIN.
M
IN
M
IN
M
IN
TURNING SPACE
REF. SECTION 304 TURNING SPACE
CLEAR FLOOR SPACE & DIAMETER
TURNING SPACE
T-TURN CLEAR FLOOR SPACE
ELEVATION
M
IN
" M A
X
AREA
OF
MIN CLEAR
1'-6"
M
IN
C L
E A
R
REFUGE
TACTILE SIGN
REF. SECTION 703.4
TWO HINGED DOORS IN SERIES
POCKET DOOR CLEARANCES
FRONT APPROACH
PLAN
ELEVATION
M
IN
" M A
X
AREA
OF
REFUGE
TACTILE SIGN
PAIRS OF
DOORS
REF. SECTION 703.4
WALL MOUNTED FIRE ALARM
DEVICE. MOUNT DEVICE SO
THAT THE ENTIRE LENS IS NOT
LESS THAN 80" OR MORE THAN
96" ABOVE FINISH FLOOR
BASELINE OF THE HIGHEST
TACTILE CHARACTER
BASELINE OF THE
LOWEST
TACTILE CHARACTER
LOCATE SIGN ON
LATCH SIDE OF DOOR
ELEVATION
M
IN
"M A
X
AREA
OF
REFUGE
BASELINE OF THE HIGHEST
TACTILE CHARACTER
BASELINE OF THE
LOWEST
TACTILE CHARACTER
LOCATE SIGN TO
RIGHT OF RIGHT
HAND DOOR
BASELINE OF THE HIGHEST
TACTILE CHARACTER
BASELINE OF THE
LOWEST
TACTILE CHARACTER
LOCATE SIGN ON
INACTIVE LEAF
ACTIVE LEAFSINACTIVE LEAF
ACTIVE LEAF
MIN.
22"
CLEAR OPENING
32" MIN.
SLIDING OR
FOLDING DOOR
SLIDING OR
FOLDING DOOR
3'-6" MIN.
PARALLEL TO DOOR
M
IN
IF
P A
R A
L L E
L
D
O R
I S
M
IN
22" MIN.
3'-0" MIN.
X
T O
H
IG
H E
S
P E
R A
B L E
P A
R T
M A
X
M
IN
(a) (b)
M A
X
20" MAX >20"-25" MAX
M A
X
Figure 308.3.1 Unobstructed Side Reach
10" MAX
M
IN
M A
X
Figure 308.3.2 Obstructed High
Side Reach
(a) (b)
M A
X
10" MAX
M A
X
M A
X
M A
X
>10"-24" MAX
Figure 308.2.1 Unobstructed Front Reach
Figure 308.2.2 Obstructed
Front Reach
REACH RANGES
REF. SECTION 308
1. DRAWINGS ON THIS SHEET REPRESENT THE
REQUIREMENTS SET BY THE TEXAS ACCESSIBILITY
STANDARDS (TAS) OF THE ARCHITECTURAL BARRIERS
ACT ARTICLE 9102, TEXAS CIVIL STATUTES EFFECTIVE
MARCH 12, 2012. THE CONTRACTOR IS TO COMPLY WITH
THESE STANDARDS.
2. THESE REQUIREMENTS ARE MINIMUMS SET FORTH BY
THE TEXAS ACCESSIBILITY STANDARDS AND MAY NOT
REFLECT THE ACTUAL SCOPE OF WORK. THE
CONSTRUCTION DOCUMENTS SHALL GOVERN OVER
THESE STANDARDS EXCEPT WHERE THE DOCUMENTS
DO NOT MEET THE MINIMUM REQUIREMENTS SHOWN ON
THIS SHEET. CONTRACTOR TO NOTIFY THE ARCHITECT
IMMEDIATELY IF ANY CONDITIONS ARISE THAT DO NOT
MEET THESE STANDARDS
Revisions:
A u st in
S a n A n to n io
H o u s to n
B a rt o n S p ri n g s R o a d S u it e A u st in Te xa s
B ro a d w a y S u it e S a n A n to n io Te xa s
F a n in S tr e e t, S u it e H o u st o n Te xa s p .4 .7 f .4 .7 p .2 .6 f .2 .6 p .4 .1 f .4 .1
C R e v it P ro je c ts
\1
S
C U
C
IS
D C le m e n s H
S C a fe te ri a
S e rv in g S n a c k B a r_ a rc h c e n tr a l_ jm o o re C
M
J N
.r v t
/1
/2
:5
:0
A
M
C L
E M
E N
S H
S C
A F
E T
E R
IA
S
E R
V
IN
G L
IN
E
R E
N O
V A
T
IO
N E
LB
E L R O A D S C H E R
TZ
TE
X A S
S C U C I N D E P E N D E N T S C H O O L D
IS
TR
IC
T
04/11/2024
Project No. 1403.18
CONTRACT DOCUMENTS
ADULT TAS ACCESSIBILITY
G2.1
O 'C O N N E
LL
R O B E R
TS
O N
IN
C
O 'C O N N E
LL
R O B E R
TS
O N
IN
C
GENERAL TAS NOTES
NO. DESCRIPTION DATE
1000 COORDINATION
A. The Contractor shall compare the Architectural, Structural, Mechanical, Electrical, Plumbing, and other series drawings and report any discrepancies between each set of drawings and within each set of drawings prior to fabrication and installation of any structural members.
B. Only larger sleeve openings and framed openings in structural framing component members are indicated on the Structural Drawings. However, all sleeves, inserts and openings, including frames and/or sleeves shall be provided for passage, provision and/or incorporation of the work of the contract, including but not limited to Mechanical, Electrical and Plumbing work. This work shall include the coordination of sizes, alignment, dimensions, position, locations, elevations and grades as required to serve the intended purpose. Openings not indicated on the Structural Drawings, but required as noted above, shall be submitted to the Engineer for review.
C. Refer to Architectural, Mechanical, Electrical and Plumbing drawings for floor elevations, slopes, drains and location of depressed and elevated floor areas.
D. Compatibility of the structure and provisions for building equipment supported on or from structural components shall be verified as to size, dimensions, clearances, accessibility, weights and reaction with the equipment for which the structure has been designed prior to submission of shop drawings and data for each piece of equipment and for structural components. Differences shall be noted on the submittals.
E. Shop drawings shall be prepared for all structural items and submitted for review by the Engineer.
Structural Drawings shall not be reproduced and used as shop drawings. All items deviating from the Structural Drawings or from previously submitted shop drawings shall be clouded.
F. The details designated as "Typical Details" apply generally to the Structural Drawings in all areas where conditions are similar to those described in the details.
G. All dimensions and conditions of existing construction shall be verified at the job site prior to the preparation of shop drawings. Differences between existing construction and that shown on the Structural Drawings shall be referred to the Architect. Differences shall also be clouded on the shop drawings.
H. All structural elements of the project have been designed by the Engineer to resist the required Code vertical and lateral forces that could occur in the final completed structure only. It is the responsibility of the Contractor to provide all required bracing during construction to maintain the stability and safety of all structural elements during the construction process until the lateral-load resisting or stability-providing system is completely installed and the structure is completely tied together. Temporary supports shall not result in the overstress or damage of the elements to be braced nor any elements used as brace supports.
I. The Contract Structural Drawings and Specifications represent the finished structure, and except where specifically shown do not indicate the means or methods of construction. The Contractor and their Sub-Contractors shall supervise and direct the Work and shall be solely responsible for all construction means, methods, procedures, techniques, sequences and safety measures including, but not limited to, adherences to all OSHA guidelines. The Engineer shall not have control of, and shall not be responsible for, construction means, methods, techniques, sequences or procedures, for safety precautions and programs in connection with the Work, for the acts or omissions of the Contractor, Subcontractors, or any other person performing any of the Work, or for the failure of any of these persons to carry out the Work in accordance with the Structural Contract Documents.
J. Where conflict exists among the various parts of the Structural Contract Documents, Structural Drawings, General Notes, and Specifications, the strictest requirements, as indicated by the Engineer, shall govern.
K. Periodic site observation by field representatives of Intelligent Engineering Services, LLP (IES) is solely for the purpose of determining if the Work is proceeding in accordance with the Structural Contract Documents. This limited site observation is not intended to be a check of the quality or quantity of the Work, but rather a periodic check in an effort to inform the Owner against defects and deficiencies in the work of the Contractor.
1010 SUBSTITUTIONS
A. All requests for substitutions of materials or details shown in the Structural Contract Documents shall be submitted for approval during the bidding period.
B. Once bids are accepted, proposed substitutions will be considered only when they are officially submitted with an identified savings or duration to be deducted from the contract and/or schedule impact. Submittals not satisfying the above criteria will not be reviewed.
1020 CODES
A. The General Building Code used as the basis for the structural design is as follows:
2021 International Building Code
1030 IBC 2021 DESIGN LOADS
A. Dead Loads include the self-weight of the structural elements and the following superimposed loads:
Ceiling and Mechanical at roof 10 psf
B. Live Loads
OCCUPANCY OR USE UNIFORM CONCENTRATED
(psf) (lbs.)
Partitions at areas with Live Load 15 N/A less than 80 psf Dining rooms 100 N/A Kitchens (Commercial) 150 Equip. Wt Restrooms 60 2000 Schools
Classrooms 40 1000 First floor corridors 100 1000
Notes:
1. Live load shall not be reduced.
C. Roof Live Loads
ROOF USE ROOF LIVE LOAD
UNIFORM CONCENTRATED
Ordinary Flat, Pitched, and Curved Roofs 20 psf N/A
D. Snow Loads
Ground snow load, Pg 5 psf Snow exposure factor, Ce 1.0 Importance factor, Is 1.0 Thermal factor, Ct 1.0 Flat Roof Snow Load [XX] psf
E. Roof Rain Loads
Rain Intensity, i 4.25 in/hr
F. Wind Loads
1. Wind lateral load on structural frame is based on ASCE 7 using the following:
Ultimate Design Wind Speed (Vult) 115 mph Nominal Design Wind Speed (Vasd) 90 mph Exposure Category C Internal Pressure Coefficient, GCpi +/-0.18 Risk Category II
G. Seismic Loads
1. The structure and structural components of the building have been designed in accordance with General Building Code with the following criteria:
Seismic Importance Factor, Ie [XX] Risk Category [XX] Mapped Spectral Response Accelerations
Ss (g) [XX] S1 (g) [XX]
Site Class [XX] Design Spectral Response Accelerations
SDS (g) [XX] SD1 (g) [XX]
Seismic Design Category [XX] Basic Seismic-force-resisting system [XX] Design Base Shear, V [XX] Seismic Response Coefficient(s), Cs [XX] Response Modification Factor(s), R [XX] Analysis Procedure Used [XX]
1030 IBC 2021 DESIGN LOADS (CONT)
H. Mechanical/Kitchen Equipment Loads
1. Loading for mechanical rooms and kitchens are based on the weights of equipment and concrete pads as indicated on the Structural Drawings. The Contractor shall submit actual weights of equipment to be used in the project to the Structural Engineer for verification of loads used in the design at least three weeks prior to fabrication and construction of the supporting structure. Any revisions in equipment type, size, or quantity shall be reported to the Architect immediately for verification of the structural design.
1100 SUBMITTALS
A. Shop drawings shall be prepared for all structural items and submitted for review by the Engineer.
Structural Drawings shall not be reproduced and used as shop drawings. All items deviating from the Structural Drawings or from previously submitted shop drawings shall be clouded.
B. Contractor shall review shop drawings for compliance with the Structural Drawings and shall certify that they have done so by a stamp noting that the drawings have been "Approved" and which bears the signature (or initials) of an authorized representative of the Contractor and the date.
Submittals which do not reflect the Contractor's approval, signature and date will be returned without review.
C. Contractor shall be responsible for delays caused by rejection of inadequate shop drawings.
D. where review and return of shop drawings is required or requested, the Engineer will review each submittal and, where possible, return within two weeks of receipt.
E. Corrections or comments on shop drawings or manufacturer's data sheets do not relieve the Contractor from compliance with requirements of the plans and specifications. Engineer's review is for general conformance with the requirements of the Structural Drawings. Contractor is responsible for confirming and correcting all quantities and dimensions, selecting fabrication processes and techniques of construction, and coordinating the work with that of all other contractors.
F. Refer to individual sections for specific submittal requirements.
2480 CONCRETE FOOTINGS
A. Concrete footing design is based on an allowable net bearing capacity of 1500 psf in accordance with the 2021 IBC Chapter 18.
B. Footings not specifically located on the plan shall be located on centerline of pilaster or column above. Where no pilaster or column occurs, locate on centerline of wall or beam.
C. Elevation of top of plinths/footings, unless noted otherwise on the Structural Drawings, is at the bottom of the deepest intersecting beam or wall supported by the footing.
D. Footing excavations shall be to neat lines and shall be free of loose or wet materials.
E. Reinforcing steel shop drawings shall include placing drawings for templates to set dowels in footings.
3000 CAST-IN-PLACE CONCRETE
A. Structural Concrete Code: Building Code Requirements for Structural Concrete, American Concrete Institute, ACI 318, as referenced by the General Building Code.
B. Classes of Concrete
1. All concrete shall conform to the requirements as specified in the table below, unless noted otherwise on the Structural Drawings:
2. Concrete Mix Schedule:
Conc Strength Agg Max Agg Slump Max Class psi Type Size Inches w/c Notes
A 3000 NWT 3/4" 3-5 ---
a. "NWT" refers to normal concrete having an dry unit weight of approximately 145 pcf (ASTM c33 AGGREGATE)
b. Where the w/c ratio is not indicated in the Concrete Mix Schedule, it shall be as necessary to meet strength requirements.
c. Where the w/c ratio is shown, it shall be adhered to regardless of the strength requirements.
d. Strength" is required compressive cylinder strength at an age of 28 days.
e. "Maximum aggregate size" is defined as first sieve with greater than 15 cumulative percent retained.
C. Provide 4 1/2 percent plus or minus 1 1/2 percent of entrained air in concrete permanently exposed to the weather and elsewhere at the contractor’s option.
D. Horizontal construction joints in concrete placements shall be permitted only where indicated on the Structural Drawings. All vertical construction joints shall be made in the center of spans in accordance with the typical details. Contractor shall submit proposed locations for construction joints not shown on the Structural Drawings for review by the Architect and Engineer. Additional construction joints may require additional reinforcing as specified by the Engineer which shall be provided by the contractor at no additional cost to the owner.
E. Embedded conduits, pipes, and sleeves shall meet the requirements of ACI 318, and the following:
1. Conduits and pipes running within a slab, beam, or wall shall not be larger in outside dimension than 1/3 the overall thickness of the slab, wall or beam and shall be located within the middle third of that thickness.
2. Conduits, pipes, and sleeves passing horizontally through a beam shall not be larger in outside dimension than 1/3 the overall depth of the beam and shall be located within the middle third of that depth.
3. Conduits, pipes, and sleeves passing vertically through a beam shall utilize a sleeve not larger in outside dimension than 1/3 the overall width of the beam or 6 inches (whichever is less).
The sleeve shall be made of hot dip galvanized schedule 40 steel.
4. Conduits, pipes and sleeves shall not be spaced closer than three diameters or widths on center.
F. Concrete sampling for quality assurance: Concrete that is pumped shall be sampled at the point of discharge from the truck.
G. Submittal: Submit proposed mix designs in accordance with ACI 301, chapter 4.2.3. Each proposed mix design shall be accompanied by a record of past performance or by three laboratory trial mixtures with confirmation tests
3200 CONCRETE REINFORCING
A. Concrete reinforcement for the project shall conform to the following:
1. All reinforcing steel shall be new billet steel in accordance ASTM A615, Grade 60, unless noted otherwise in the Structural Drawings or these notes.
2. Welded wire reinforcement. Welded smooth wire reinforcement, ASTM A1064, yield strength 65,000 psi where noted on the Structural Drawings. Welded wire reinforcement to be provided in flat sheets.
B. Detailing of reinforcing steel shall conform to the American Concrete Institute 315 Detailing Manual and all hooks and bends in reinforcing bars shall conform to ACI detailing standards, unless noted otherwise on the Structural Drawings.
C. Welded Wire Reinforcement shall be continuous across the entire concrete surface and not interrupted by beams or girders and properly lapped one cross wire spacing plus 2”.
D. Reinforcement in Topping Slabs shall be welded smooth wire reinforcement minimum 6 x 6 W2.9 x W2.9 in all topping slabs unless specified otherwise on the Structural Drawings.
E. Reinforcement in Housekeeping Pads shall be welded smooth wire reinforcement 6 x 6 W2.9 x W2.9 minimum in all housekeeping pads supporting mechanical equipment whether shown on the Structural Drawings or not unless heavier reinforcement is called for on the Structural Drawings.
F. In unscheduled grade beams, walls, and slabs, detail reinforcing as follows:
1. Class A lap beam top reinforcing bars at mid span.
2. Class A lap beam bottom reinforcing bars at the supports.
3. Provide Class B lap at other location pending Engineer’s approval.
4. Provide standard hooks in top bars at cantilever and discontinuous ends of beams, walls and slabs.
5. Provide corner bars for all horizontal bars at the inside and outside faces of intersecting beams or walls. Corner bars are not required if horizontal bars are hooked.
6. Provide 2-#4 diagonal bars at all slab re-entrant corners placed under the top mat of steel.
3200 CONCRETE REINFORCING (CONT)
G. Welding of reinforcing steel will not be permitted unless specifically shown on the Structural Drawings.
H. Heat shall not be used in the fabrication or installation of reinforcement.
I. Reinforcing steel clear cover shall be as follows:
1. Slab-on-grade 3/4" top
2. "Exterior Exposure refers to concrete exposed to earth or weather
J. Submittal: Submit shop drawings for fabrication, bending, and placement of concrete reinforcement. Comply with ACI 315 "Details and Detailing of Concrete Reinforcement". Do not reproduce the Structural Drawings for use as shop drawings.
5050 POST-INSTALLED ANCHORS AND DOWELS
A. Expansion Anchors shall be one of the following:
1. Concrete:
a. Kwik Bolt TZ2, Hilti Inc.
b. Strong Bolt, Simpson Strong-Tie
c. Power-Stud+ SD1, DeWalt (Powers)
B. Screw Anchors shall be one of the following:
1. Concrete:
a. Kwik HUS-EZ, Hilti Inc.
b. Titen HD, Simpson Strong-Tie
c. Wedge-Bolt+, DeWalt (Powers)
C. Adhesive Anchors shall be one of the following:
1. Concrete:
a. HIT-RE 500-V3, Hilti Inc.
b. HIT-HY 200, Hilti inc.
c. Pure 110+, DeWalt (Powers)
d. AC200+, DeWalt (Powers)
e. SET 3G, Simpson Strong-Tie.
D. Adhesive Doweling
1. Adhesive doweling system shall be one of the following products:
a. HIT RE 500-V3, Hilti Inc.
b. Pure 110+, DeWalt (Powers)
c. AC200+, DeWalt (Powers)
d. SET 3G, Simpson Strong-Tie.
E. Install dowels in strict accordance with the adhesive manufacturer's instructions.
F. Clean out holes with compressed air after drilling per manufacturer's printed installation instructions or use manufacturer's alternate hole cleaning procedures.
G. Unless noted otherwise on the structural drawings, embedment depth shall be as required to develop full yield strength of the embedded dowels.
H. Prior to drilling holes for dowels, locate existing reinforcing steel with a Pachometer (R-Meter) or by drilling 1/4 inch diameter pilot holes. Relocate bolt holes as required to avoid existing reinforcement.
I. Anchors and dowels of the size and embedment shown on the Drawings shall be installed in accordance with the Contract Documents, the manufacturer's recommendations, and the manufacturer's current ICC ES report for the anchor. If conflicts exist between these referenced documents, the most stringent requirements shall govern.
J. The Contractor shall locate all existing reinforcing steel and other embedded items contained in the concrete using non-destructive methods and shall position anchor locations to avoid conflicts with existing embedded items. Anchor locations can be adjusted by a maximum of 1 1/2 inch from detailed locations to avoid conflicts, unless noted otherwise. Submit an as-built of anchor locations to engineer.
K. Based on field verified locations of reinforcing steel and embedded items, the Contractor shall create templates for each anchor group. Submit template dimensions for review prior to fabrication of connection plates.
L. Holes for anchors and dowels shall be drilled in a continuous operation using the bit type and size recommended by the anchor manufacturer. Diamond cored holes shall not be used unless noted otherwise on the structural drawings. Holes shall be drilled perpendicular to the concrete surface and shall not be enlarged or redirected at any point along its length. All debris shall be blown out of the holes with compressed air after drilling.
M. All abandoned holes shall be filled with non-shrink grout.
N. Holes in connection plates shall be no more than 1/16 inch larger than the anchor diameter. If larger holes are required for erection purposes, Contractor shall notify Engineer such that a plate washer size can be provided.
O. Installation of anchors and dowels shall be continuously inspected by the testing agency to ensure that holes are of specified size, and that bolts are properly installed including application of minimum installation torques.
5100 STRUCTURAL STEEL
A. Structural Steel Code: Specification for Structural Steel Buildings, American Institute of Steel Construction Inc., ANSI/AISC 360, as referenced by the General Building Code.
B. Material
1. All hot rolled steel members shall be new and conform to ASTM specification A6.
2. ASTM Specification and Grade. Clearly mark the grade on each member
3. Unless Noted otherwise on the Structural Drawings, structural steel members shall be:
a. W-shapes shall conform to ASTM A992.
b. Channels shall conform to ASTM A36.
c. Angles shall conform to ASTM A36.
d. Steel pipe shall conform to ASTM A53, Type E, Grade B.
e. Round hollow structural shape members shall conform to ASTM A500, Grade C, Fy = 46 ksi.
f. Square or rectangular hollow structural shape members shall conform to ASTM A500 Grade C, Fy = 50 ksi.
g. Structural steel plate shall conform to ASTM A36.
h. Any other steel shall conform to ASTM A36.
C. Fabrication
1. Splicing of structural steel members is prohibited without prior approval of the Engineer as to location and type of splice to be made. Any member having splice(s) not shown and detailed on shop drawings will be rejected.
2. Dimensional tolerances of fabricated structural steel shall conform to Section 6.4 of the AISC Code of Standard Practice unless noted otherwise on the Structural Drawings.
3. Shop painting: Paint structural steel with one coat of manufacturer’s standard red oxide primer applied at a rate to provide a uniform dry film thickness of 2.5 mils.
D. Erection
1. Erection tolerances of anchor bolts, embedded items, and all structural steel unless specified otherwise on the Structural Drawings shall conform to the AISC Code of Standard Practice.
2. Field cutting of structural steel or any field modifications to structural steel shall not be made without prior approval of the Engineer.
3. Contractor shall protect any unprimed structural steel from detrimental effects of corrosion, as required, until the steel is enclosed and protected by the new construction.
5100 STRUCTURAL STEEL (CONT)
E. Hot dip galvanize after fabrication all structural steel items and connections permanently exposed to the weather, whether specified on the Structural Drawings or not. Such items include, but are not limited to:
1. Shelf angles and/or loose lintels
2. Embedded plates in concrete exposed to the exterior
3. Railing exposed to weather.
4. Examine the Architectural and Structural Drawings for other items required to be hot dip galvanized. Galvanize all nuts, bolts, and washers used in connection with such steel. Field welded connections shall have welds protected with “Z.R.C. Cold Galvanizing Compound” as manufactured by Z.R.C. Company.
F. Submittal: Provide drawings showing details for fabrication and shop assembly of members, erection plans and details. Include details of connections, camber, weld profiles and sizes and spacing. Shop and erection drawings shall not be made using reproductions of the Structural Drawings.
100000 DESIGN BY CONTRACTOR
A. In accordance with the Specifications the items listed below are not included in the Contract Documents. Design of these elements shall be the responsibility of the Contractor, and shall be designed and sealed by a Professional Engineer licensed in the State of Texas.
1. Cold Formed Metal Framing
2. Embedded assemblies and inserts, clamps, hangers, trapezes, unistrut, etc. for the support of MEP systems.
3. Embedded assemblies, inserts, and/or hangers for fire suppression systems.
B. Design of the items listed above shall be in accordance with the General Building Code, and shall include all attachments to the structure.
JOSEPH H. HUIZAR
87226
1045 CENTRAL PARKWAY NORTH, SUITE 200
210.349.9098
SAN ANTONIO, TEXAS 78232
TBPE FIRM F-432IES JOB NO:
ENGINEERING COMMUNITIES FROM THE GROUND UP
ie-services.com
Revisions:
A u st in
S a n A n to n io
H o u s to n
B a rt o n
S p ri n g s
R o a d
S u it e
A u st in Te xa s
B ro a d w a y S u it e
S a n A n to n io
Te xa s
F a n in S tr e e t, S u it e
H o u st o n Te xa s p
.4
.7 f
.4
.7 p
.2
.6 f
.2
.6 p
.4
.1 f
.4
.1
1243336
04/11/24
C U s e rs \M a ri s e la
\D o c u m e n ts \3
S
C U
C
IS
D C le m e n s H
S C a fe te ri a R e n o v (C e n tr a l)
S m a ri s e la m
.r v t
/1
/2
:0
:3
P
M
04/11/2024
Project No. 1403.18
CONTRACT DOCUMENTS
STRUCTURAL NOTES
S0.1
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
C L
E M
E N
S H
S C
A F
E T
E R
IA
S
E R
V
IN
G L
IN
E
R E
N O
V A
T
IO
N
E
LB
E L
R O
A D
S C
H E R
TZ
TE
X A
S
S C
U C
I N
D E P
E N
D E N
T S C
H O
O L
D
IS
TR
IC
T
S T R U C T U R A L N O T E S
SPECIAL INSPECTIONS TABLES FOR STRUCTURAL ELEMENTS - 2021
X--
2. Inspection tasks during welding:
1705.2.1
X
a. Control and handling of welding consumables
1) Packaging
2) Exposure control
Xb. No welding over cracked tack welds --
X
c. Environmental conditions
1) Wind speed within limits
2) Precipitation and temperature
X
d. WPS followed
1) Settings on weld equipment
2) Travel speed
3) Selected welding materials
4) Shielding gas type/flow rate
5) Preheat applied
6) Interpass temperature maintained (min/max)
7) Proper position (F, V, H, OH)
X
e. Welding techniques
1) Interpass and final cleaning
2) Each pass within profile limitations
3) Each pass meets quality requirements
Xa. Welds cleaned
3. Inspection tasks after welding:
--b. Size, length and location of welds X
c. Welds meet visual acceptance criteria
1) Crack prohibition
2) Weld/base-metal fusion
3) Crater cross section
4) Weld profiles
5) Weld size
6) Undercut
7) Porosity
X
--d. Arc strikes X
--e. Repair activities X
--f. Document acceptance or rejection of welded joint or member
X
1. Inspection tasks noted in this table are the responsibility of the Special Inspector or Quality Assurance Inspector (QAI).
The fabricator and erector are responsible for all inspection tasks indicated in AISC 360-16 Section N5 assigned to the Quality Control Inspector (QCI).
2. Inspection tasks may be coordinated with the fabricator or erector's Quality Control Inspector (QCI) where indicated with this footnote. All other tasks shall be performed by the Special Inspector.
1705.2.1
AISC 360-16
N5.4-3:
AWS D1.1
REFERENCED
STANDARD
--b. Welding procedure specifications (WPSs) available
1. Inspection tasks prior to welding:
IBC
REFERENCE
REQUIRED SPECIAL INSPECTIONS FOR WELDING OF STRUCTURAL STEEL (AISC 360-16 Table N5.4)
CONTINUOUS PERIODIC
X
7. Verify maintenance of specified curing temperature and techniques
ACI 318:
26.5.3-26.5.5
ACI 318:
26.5
6. Inspect concrete placement for proper application techniques
X
ASTM C172
ASTM C31
ACI 318:
26.5, 26.12
X
5. Prior to concrete placement, fabricate specimens for strength tests, perform slump and air content tests, and determine the temperature of the concrete
1904.1, 1904.2 ACI 318: Ch. 19, 26.4.3, 26.4.4
X
--2. Inspect anchors cast in concrete
X
REQUIRED SPECIAL INSPECTIONS OF CONCRETE CONSTRUCTION (IBC Table 1705.3)
1. Inspect reinforcement and verify placement
4. Verifying use of required design mix
CONTINUOUS PERIODIC
X
X
3. Inspect anchors post-installed in hardened concrete members
X
AISC 360-16
N5.4-1:
AWS D1.1
1705.2.1
--X
X--
X--
X--
X--
SPECIAL INSPECTIONS
1. Special Inspections shall be performed in accordance with Chapter 17 of the 2021 International Building Code (IBC) by a Special Inspector hired by the Owner to perform the Special Inspections listed below. The Special Inspector shall be qualified by an approved agency according to the City's building official to perform the special inspections for which they will be undertaking.
The Contractor shall coordinate with and notify the Special Inspector of all required tests and inspections listed in the following tables. The Special Inspector shall be responsible to verify that the items detailed in the Construction Documents were built accordingly and shall prepare, sign, and furnish inspection reports to the building official and the Architect for all time spent at the site. The Inspector shall bring discrepancies to the immediate attention of the General Contractor for correction. If the discrepancies are not corrected, the discrepancies shall be brought to the attention of the building official and to the Architect prior to the completion of that phase of the work. These special inspections are in addition to the other inspections listed in these Structural Notes or Project Specifications.
2. Where structural members and assemblies are shop fabricated, the Special Inspector shall verify that the fabricator maintains detailed fabrication and quality control procedures that provide a basis for inspection control of the workmanship and the fabricator's ability to conform to the Construction Documents and Referenced Standards, unless the fabricator is registered and approved to perform such work without special inspection.
c. Manufacturer certifications for welding consumables available
d. Material identification (type/grade)
e. Welder identification system
f. Fit-up of CJP groove welds (including joint geometry)
1) Joint preparation
2) Dimensions (alignment, root opening, root face, bevel)
3) Cleanliness (condition of steel surfaces)
4) Tacking (tack weld quality and location)
5) Backing type and fit (if applicable)
h. Configuration and finish of access holes
i. Fit-up of fillet welds
1) Dimensions (alignment, gaps at root)
2) Cleanliness (condition of steel surfaces)
3) Tacking (tack weld quality and location)
AISC 360-16
N5.4-2:
AWS D1.1
REFERENCED
STANDARD
IBC
REFERENCE
a. Adhesive anchors installed in horizontally or upwardly inclined orientations to resist sustained tension loads
b. Mechanical anchors and adhesive anchors not defined in 3.a
X--
ACI 318: Ch.
20, 25.2, 25.3, 26.6.1-26.6.3
ACI 318:
17.8.2
ACI 318:
17.8.2.4
ACI 318:
17.8.2
SPECIAL INSPECTION TYPE
SPECIAL INSPECTION TYPE
X--a. Welder qualification records and continuity records
INSPECTION FREQUENCY
INSPECTION FREQUENCY
X--
g. Fit-up of CJP groove welds of HSS t-, y-, and k-joints without backing (including joint geometry)
1) Joint preparation
2) Dimensions (alignment, root opening, root face, bevel)
3) Cleanliness (condition of steel surfaces)
4) Tacking (tack weld quality and location)
--f. Placement and installation of steel headed stud anchors X
g. No prohibited welds have been added without the approval of the Engineer of Record X--
X--j. Check welding equipment
JOSEPH H. HUIZAR
87226
1045 CENTRAL PARKWAY NORTH, SUITE 200
210.349.9098
SAN ANTONIO, TEXAS 78232
TBPE FIRM F-432IES JOB NO:
ENGINEERING COMMUNITIES FROM THE GROUND UP
ie-services.com
Revisions:
A u st in
S a n A n to n io
H o u s to n
B a rt o n
S p ri n g s
R o a d
S u it e
A u st in Te xa s
B ro a d w a y S u it e
S a n A n to n io
Te xa s
F a n in S tr e e t, S u it e
H o u st o n Te xa s p
.4
.7 f
.4
.7 p
.2
.6 f
.2
.6 p
.4
.1 f
.4
.1
1243336
04/11/24
C U s e rs \M a ri s e la
\D o c u m e n ts \3
S
C U
C
IS
D C le m e n s H
S C a fe te ri a R e n o v (C e n tr a l)
S m a ri s e la m
.r v t
/1
/2
:0
:4
P
M
04/11/2024
Project No. 1403.18
CONTRACT DOCUMENTS
SPECIAL INSPECTIONS
S0.2
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
C L
E M
E N
S H
S C
A F
E T
E R
IA
S
E R
V
IN
G L
IN
E
R E
N O
V A
T
IO
N
E
LB
E L
R O
A D
S C
H E R
TZ
TE
X A
S
S C
U C
I N
D E P
E N
D E N
T S C
H O
O L
D
IS
TR
IC
T
A/C - AIR CONDITIONER
AB - ANCHOR BOLT
ABV - ABOVE
ACI - AMERICAN CONCRETE INSTITUTE
ADDL - ADDITIONAL
ADH - ADHESIVE
ADJ - ADJACENT
AEC - ARCHITECTURALLY EXPOSED CONCRETE
AESS - ARCHITECTURALLY EXPOSED STRUCTURAL STEEL
AFF - ABOVE FINISHED FLOOR
AGGR - AGGREGATE
AHU - AIR HANDLING UNIT
AISC - AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT - ALTERNATE
APPROX - APPROXIMATE
ARCH - ARCHITECT (OR) ARCHITECTURAL
B TO B - BACK TO BACK
BD - BOARD
B.O. - BOTTOM OF
BF - BACK FACE
BFF - BELOW FINISH FLOOR
BIL - BOTTOM INSIDE LAYER
BL - BUILDING LINE
BLDG - BUILDING
BLKG - BLOCKING
BM - BEAM
BOL - BOTTOM OUTSIDE LAYER
BOS - BOTTOM OF STEEL
BOTT - BOTTOM
BP - BASE PLATE
BRDG - BRIDGING
BRG - BEARING
BRKT - BRACKET
BRL - BRICKLEDGE
BSMT - BASEMENT
BTWN - BETWEEN
C - CAMBER (OR) COMPRESSION
CANT - CANTILEVER
CFS - COLD FORMED STEEL
CG - CENTER OF GRAVITY
CGS - CENTER OF GRAVITY OF STRAND
CIP - CAST-IN-PLACE
CJ - CONTROL JOINT
CJP - COMPLETE JOINT PENETRATION
CL - CENTER LINE
CLG - CEILING
CLR - CLEAR (OR) CLEARANCE
CMU - CONCRETE MASONRY UNIT
COL - COLUMN
C OR COMP - COMPRESSION
CONC - CONCRETE
CONN(S) - CONNECTION(S)
CONST - CONSTRUCTION
CONST JT - CONSTRUCTION JOINT
CONT - CONTINOUS
CONTR - CONTRACTOR
COORD - COORDINATE
CVR - COVER
DBA - DEFORMED BAR ANCHORS
DBL - DOUBLE
DE - DECK EDGE
DEV - DEVELOPMENT
DFL - DOUGLAS FIR LARCH
DIA - DIAMETER
DIAG - DIAGONAL
DIM(S) - DIMENSION(S)
DKG - DECKING
DL - DEAD LOAD
DN - DOWN
DS - DOWNSPOUT
DTL - DETAIL
DWG(S) - DRAWING(S)
DWL(S) - DOWELS
EA - EACH
EF - EACH FACE (OR) EXHAUST FAN
EJ - EXPANSION JOINT
EL - ELEVATION
ELEC - ELECTRICAL
ELEV - ELEVATOR
EMBED - EMBEDMENT
ENGR - ENGINEER
EOR - ENGINEER OF RECORD
EQ - EQUAL (OR) EQUIVALENT
EQUIP - EQUIPMENT
EW - EACH WAY
EXIST - EXISTING
EXP - EXPANSION
EXT - EXTERIOR
EXTN - EXTENSION
F TO F - FACE TO FACE
FABR - FABRICATOR
FD - FLOOR DRAIN
FDN - FOUNDATION
FFE - FINISHED FLOOR ELEVATION
FIN - FINSH (OR) FINISHED
FIN FL - FINISHED FLOOR
FL - FLOOR
FLG - FLANGE
FP - FIREPROOF(ING)
FRMG - FRAMING
FS - FAR SIDE
FT - FOOT (OR) FEET
FTG - FOOTING
FV - FIELD VERIFY
GA - GAGE (OR) GAUGE
GALV - GALVANIZED
GC - GENERAL CONTRATOR
GLULAM - GLUE LAMINATED TIMBER
GR - GRADE
GR BM - GRADE BEAM
HB - HORIZONTAL BRACE
HCA - HEADED CONCRETE ANCHOR
HDG - HOT DIPPED GALVANIZED
HDR - HEADER
HI - HIGH
HK - HOOK
HL - HOLE
HORIZ - HORIZONTAL
HP - HIGH POINT
HS - HEADED STUD
HSS - HOLLOW STRUCTURAL SECTION
HT - HEIGHT
ID - INSIDE DIAMETER
IF - INSIDE FACE
IN - INCH
INFO - INFORMATION
INT - INTERIOR
INTERM - INTERMEDIATE
JG - JOIST GIRDER
JST(S) JOIST(S)
JT - JOINT
K - KIPS (1000 LBS)
KLF - KIP PER LINEAR FOOT
KSF - KIP PER SQUARE FOOT
KSI - KIP PER SQUARE INCH
L - LENGTH
LBS - POUNDS
LL - LIVE LOAD
LLH - LONG LEG HORIZONTAL
LLV - LONG LEG VERTICAL
LO - LOW
LOC - LOCATION
LONG - LONGITUDINAL
LP - LOW POINT
LSH - LONG SIDE HORIZONTAL
LSL - LONG SLOTTED HOLES
LSV - LONG SIDE VERTICAL
LVL - LAMINATED VENEER LUMBER
LW - LIGHTWEIGHT
LWC - LIGHTWEIGHT CONCRETE
M - MOMENT
MAS - MASONRY
MATL - MATERIAL
MAX - MAXIMUM
MC - MOMENT CONNECTION(S)
MECH - MECHANICAL
MEP - MECHANICAL, ELECTRICAL, PLUMBING
MEZZ - MEZZANINE
MFR - MANUFACTURER
MID - MIDDLE
MIN - MINIMUM
MISC - MISCELLANEOUS
MTL - METAL
NF - NEAR FACE
NIC - NOT IN CONTRACT
NOM - NOMINAL
NS - NON-SHRINK
NTS - NOT TO SCALE
OC - ON CENTER
OCEW - ON CENTER EACH WAY
OD - OUTSIDE DIAMETER (OR) OVERFLOW DRAIN
OF - OUTSIDE FACE
OH - OPPOSITE HAND
OPNG(S) - OPENING(S)
OPP - OPPOSITE
P - PAN
P/C - PRECAST CONCRETE
P/E - PRE-ENGINEERED
PAF - POWDER ACTUATED FASTENER
PAR - PARALLEL
PCF - POUNDS PER CUBIC FOOT
PEMB - PRE-ENGINEERED METAL BUILDING
PERP - PERPENDICULAR
PI - PLASTICITY INDEX
PJ - PANEL JOINT
PJP - PARTIAL JOINT PENETRATION
PL - PLATE
PLF - POUNDS PER LINEAR FOOT
PLYWD - PLYWOOD
PREFAB - PREFABRICATED
PRELIM - PRELIMINARY
PROJ - PROJECTION
PSF - POUNDS PER SQUARE FOOT
PSI - POUNDS PER SQUARE INCH
PSL - PARALLEL STRAND LUMBER
PT - POINT (OR) PRESSURE TREATED
P-T - POST-TENSION(ED)
QTY - QUANTITY
R - RADIUS (OR) REACTION (OR) REMAINDER
RD - ROOF DRAIN
REINF - REINFORCE(ING)(ED)(MENT)
REQ - REQUIRE(MENT)
REQD - REQUIRED
RET - RETAINING
RET SYS - RETENTION SYSTEM
RF - ROOF
RIS - RISER
RM - ROOM
RO - ROUGH OPENING
RTU - ROOF TOP UNIT
SCHED - SCHEDULE(D)
SECT - SECTION
SF - SQUARE FOOT
SHT - SHEET
SHTG - SHEATHING
SIM - SIMILAR
SJI - STEEL JOIST INSTITUTE
SL - SLOPE
SOG - SLAB ON GRADE
SP - SOUTHERN PINE
SPA - SPACE
SPECD - SPECIFIED
SPEC(S) - SPECIFICATION(S)
SQ - SQUARE
SS - STAINLESS STEEL
SSL - SHORT SLOTTED HOLE
STAGG - STAGGERED
STD - STANDARD
STIFF - STIFFENER
STIRR - STIRRUPS
STL - STEEL
STRUCT - STRUCTURE (OR) STRUCTURAL
SUBCONTR - SUBCONTRACTOR
SW - SHEARWALL (OR) SIDEWALK
T - TENSION
T.O. - TOP OF
T&B - TOP AND BOTTOM
T&G - TONGUE AND GROOVE
TEMP - TEMPERATURE
THK - THICK
THRD - THREAD(ED)
TIL - TOP INSIDE LAYER
TOB - TOP OF BEAM
TOC - TOP OF CONCRETE
TOF - TOP OF FOOTING
TOJ - TOP OF JOIST
TOL - TOP OUTSIDE LAYER
TOP - TOP OF PIER
TOPC - TOP OF PIER (PILE) CAP
TOS - TOP OF STEEL
TOW - TOP OF WALL
TR - TREAD
TRANSV - TRANSVERSE
TYP - TYPICAL
UNO - UNLESS NOTED OTHERWISE
V - SHEAR
VB - VERTICAL BRACE
VERT - VERTICAL
W - WIDTH
W/ - WITH
W/O - WITHOUT
WD - WOOD
WDW - WINDOW
WL - WIND LOAD
WP - WORK POINT
WPFG - WATERPROOFING
WS - WATERSTOP
WT - WEIGHT
WWM - WELDED WIRE MESH
X-STR - EXTRA STRONG
XX-STR - DOUBLE EXTRA STRONG
STRUCTURAL ABBREVIATIONS
F8 F9 F10 F11
FB
FA
5'-0" 15'-9" 5'-0"
25'-9"
HSS3x3x3/16
9' -4
FA.5
1"
S3.1
HSS4x4x3/16
TYP, UNO
S3.1
S3.2
F8 F9 F10 F11
FB
FA
5'-0" 15'-9" 5'-0"
25'-9"
FA.59'
-4
1"
S3.1
S3.2
HSS6x4x3/16 (LSH)
(TOS EL= 12'-7")
HSS6x4x3/16 (LSH)
H S S x x /1
L S H
BEAM SPLICE
(GC OPTION)
(TOS EL=
12'-7")
S3.1
(T O
S E
L
S3.1
H S S x x /1
L S H
(T O
S E
L
S3.1
BEAM SPLICE
(GC OPTION)
S3.1
S3.1
S3.1
HSS6x4x3/16 (LSH)
(TOS EL=
12'-7")
(TOS EL= 12'-7")
W12x19
HS
S6 x3 x3
/1
(L
SH
) HSS6x3x3/16 (LSH)
JOSEPH H. HUIZAR
87226
1045 CENTRAL PARKWAY NORTH, SUITE 200
210.349.9098
SAN ANTONIO, TEXAS 78232
TBPE FIRM F-432IES JOB NO:
ENGINEERING COMMUNITIES FROM THE GROUND UP
ie-services.com
Revisions:
A u st in
S a n A n to n io
H o u s to n
B a rt o n
S p ri n g s
R o a d
S u it e
A u st in Te xa s
B ro a d w a y S u it e
S a n A n to n io
Te xa s
F a n in S tr e e t, S u it e
H o u st o n Te xa s p
.4
.7 f
.4
.7 p
.2
.6 f
.2
.6 p
.4
.1 f
.4
.1
1243336
KEY PLAN
NTS
AREA OF
NEW WORK
04/11/24
C U s e rs \M a ri s e la
\D o c u m e n ts \3
S
C U
C
IS
D C le m e n s H
S C a fe te ri a R e n o v (C e n tr a l)
S m a ri s e la m
.r v t
/1
/2
:0
:4
P
M
04/11/2024
Project No. 1403.18
CONTRACT DOCUMENTS
SNACK BAR FRAMING
PLANS
S1.1
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
C L
E M
E N
S H
S C
A F
E T
E R
IA
S
E R
V
IN
G L
IN
E
R E
N O
V A
T
IO
N
E
LB
E L
R O
A D
S C
H E R
TZ
TE
X A
S
S C
U C
I N
D E P
E N
D E N
T S C
H O
O L
D
IS
TR
IC
T north
SCALE: 1/4" = 1'-0"
1 SNACK BAR FLOOR PLAN
north
SCALE: 1/4" = 1'-0"
2 SNACK BAR CEILING FRAMING PLAN
FC
F1 F2 F3 F4 F5 F6 F7
FD
(F
IE
L D
V E R
IF
Y
HSS4x4x3/16
TYP, UNO
60'-0"
10'-8" 12'-0" 8'-4" 8'-4" 12'-0" 8'-8"
S3.1
S3.1
S3.1
CL HSS COL
S3.2
EXISTING STEEL
COLUMN
EXISTING CMU
WALL
EXISTING STEEL
COLUMN
EXISTING CMU
WALL
(F
IE
L D
V E R
IF
Y
CL EXIST STL COL
EXISTING
STEEL
COLUMN
FC
F1 F2 F3 F4 F5 F6 F7
FD
(F
IE
L D
V E R
IF
Y
HSS6x4x3/16 (LSH)
H S S x x /1
L S H
HSS6x4x3/16 (LSH) HSS6x4x3/16 (LSH) H S S x x /1
L S H
60'-0"
10'-8" 12'-0" 8'-4" 8'-4" 12'-0" 8'-8"
HSS
6x3 x3 /16
(L
SH)
S3.1
S3.1
CL EXIST
STEEL COLUMN
BEAM
SPLICE
BEAM
SPLICE
(F
IE
L D
V E R
IF
Y
S3.2
HSS6x4x3/16 (LSH)
S3.1
S3.1
S3.1
S3.1
EXISTING STEEL
COLUMN
EXISTING CMU
WALL
(T O
S E
L
/4
(TOS EL= 13'-11 3/4") (TOS EL= 13'-11 3/4") (TOS EL= 13'-11 3/4")
EXISTING STEEL
COLUMN
EXISTING CMU
WALL
EXISTING
STEEL
COLUMN
CL HSS COL
CL EXIST STL COL
(T O
S E
L
/4
OH
JOSEPH H. HUIZAR
87226
1045 CENTRAL PARKWAY NORTH, SUITE 200
210.349.9098
SAN ANTONIO, TEXAS 78232
TBPE FIRM F-432IES JOB NO:
ENGINEERING COMMUNITIES FROM THE GROUND UP
ie-services.com
Revisions:
A u st in
S a n A n to n io
H o u s to n
B a rt o n
S p ri n g s
R o a d
S u it e
A u st in Te xa s
B ro a d w a y S u it e
S a n A n to n io
Te xa s
F a n in S tr e e t, S u it e
H o u st o n Te xa s p
.4
.7 f
.4
.7 p
.2
.6 f
.2
.6 p
.4
.1 f
.4
.1
1243336
KEY PLAN
NTS
AREA OF
NEW WORK
04/11/24
C U s e rs \M a ri s e la
\D o c u m e n ts \3
S
C U
C
IS
D C le m e n s H
S C a fe te ri a R e n o v (C e n tr a l)
S m a ri s e la m
.r v t
/1
/2
:0
:4
P
M
04/11/2024
Project No. 1403.18
CONTRACT DOCUMENTS
CAFETERIA SERVING
AREA FRAMING PLANS
S2.1
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
C L
E M
E N
S H
S C
A F
E T
E R
IA
S
E R
V
IN
G L
IN
E
R E
N O
V A
T
IO
N
E
LB
E L
R O
A D
S C
H E R
TZ
TE
X A
S
S C
U C
I N
D E P
E N
D E N
T S C
H O
O L
D
IS
TR
IC
T north
SCALE: 1/4" = 1'-0"
1 CAFETERIA SERVING AREA FLOOR PLAN
north
SCALE: 1/4" = 1'-0"
2 CAFETERIA SERVING AREA CEILING FRAMING PLAN
TOS EL-
SEE PLAN
EXIST CONC
JOIST (FV)
3000 PSI
CONC INFILL
(FV)
EXIST OPNG
EXISTING
TOC EL
CLIP ANGLE
L3x3x1/4
ANCHORED TO
EXIST JOIST W/
1/2"Ø EXP ACHOR
L3x3x1/4 EA
SIDE OF
OPENING
TYP
3/16" PL OVERSIZED
TO FIT OPENING + 2"
MEETING ASTM A36
6x6-W2.1xW2.1 WELDED
WIRE REINF MEETING
ASTM A1064 CENTERED
IN DEPTH OF SLAB
EXIST CONC
JOIST (FV)
S3.1
(FV)
EXIST OPNG FILL W/ CONCEXIST CONC
FLOOR SLAB
EXISTING
TOC EL
EXIST CONC
JOIST (FV)
NEW OPENING FOR SINK.
CORE DRILL CORNERS
OF NEW OPENING TO
AVOID OVERCUTS, TYP
FOR EXACT
SEE ARCH
EXIST CONC
JOIST (FV)
DIMS
(1'-5" MAX)
EXISTING
TOC EL
STEEL COLUMN,
SEE PLANTYP
1 1/2"
BASE PL1/2"x9"x9" W/
(4)-3/8"Ø RODS, "HILTI"
HAS-E x 4 3/8" AND "HILTI"
ADHESIVE HIT-HY 200-A
3/16
TYP
F8
FB
S3.1
STEEL COLUMN,
SEE PLANTYP
1 1/2"
BASE PL1/2"x10"x10" W/
(4)-3/8"Ø RODS, "HILTI"
HAS-E x 4 3/8" AND "HILTI"
ADHESIVE HIT-HY 200-A
3/16
TYP
F4
FC
S3.1
MASONRY TO
BE REMOVED
NOTES:
1. SEE ARCH DRAWINGS FOR OPENING SIZE & LOCATION.
2. SAW CUT AND INSTALL ANGLES PRIOR TO REMOVING
MASONRY AT OPENING.
3. INSTALL COVER PLATE AFTER MASONRY HAS BEEN REMOVED.
3/16" COVER PLATE
x 7 1/2" x FULL
HEIGHT OF WALL
EXISTING MASONRY
WALL TO REMAIN
CONFIRM 8" CMU
(7 5/8" WIDTH)
3/16 2-8
.TYP
L5x3x1/4 FULL
HEIGHT
GC TO FIELD
DETERMINE WALL
HEIGHT
"HILTI" SLEEVE ANCHOR
HLC-FPH 1/4" DIA
x2 1/4" AT 8"OC, IN
CENTER OF BLOCK
/2
9'-4"
HSS COL,
SEE PLAN
HSS COL,
SEE PLAN
STL BM,
SEE PLAN
FBFA
EXIST CONC
FLOOR SLAB
TOS EL=
12'-7"
S3.1
GYP CEILING FRAMING
REFER TO ARCHITECTURAL
STL BM,
SEE PLAN
TOS EL=
12'-7"
HSS COL,
SEE PLAN
STL BM,
SEE PLAN
EXIST CONC
FLOOR SLAB
FC
TOS EL=
13'-11 3/4"
GYP CEILING FRAMING
REFER TO ARCHITECTURAL
S3.1
(F V
EXIST CONC
FLOOR
SLAB
HSS COL,
SEE PLAN
/2 E M
B E D
(D O
N
V
E R
D R
IL
L
BASE PLATE,
SEE DETAILS
& 4/S3.1 5/S3.1
BOS EL=
12'-4"
STL BM,
SEE PLAN
STL COL,
SEE PLAN
BOS EL=
11'-7"
STL BM,
SEE PLAN
F1
HSS BRACE,
SEE PLAN
HSS BM,
SEE PLAN
FD
EXISTING STEEL
COLUMN
WORK POINT
"SEAT L4x4x1/4 x0'-4" LG
3/16
S3.1
3/16
FC
HSS BEAM (LSH)
W/ 3/16 CAP PL
HSS COL
BELOW
3/16
TYP
3/16
TYP
HSS BEAM (LSH)
F1
F2
FC
1'-8"
HSS6x3 BRACE (LSH) PL1/4x4" x 1'-8"
AT MID DEPTH
WORK POINT
HSS BEAM (LSH)
HSS COL
BELOW
TYP
3/16
3/16
TYP
3/16 6" E.E.
TYP
F#
FC
HSS BEAM (LSH)
HSS COL 3/16
BOS EL
HSS BEAM (LSH)
HSS COL
BELOW
14A - ELEVATION
14A
TYP
3/16
THREE
SIDES 3/16
SEAT L4x4x1/4 x0'-4"
EXISTING 8" STEEL
TUBE COLUMN
HSS BM, SEE PLAN
DIAGONAL
BRACE
JOSEPH H. HUIZAR
87226
1045 CENTRAL PARKWAY NORTH, SUITE 200
210.349.9098
SAN ANTONIO, TEXAS 78232
TBPE FIRM F-432IES JOB NO:
ENGINEERING COMMUNITIES FROM THE GROUND UP
ie-services.com
Revisions:
A u st in
S a n A n to n io
H o u s to n
B a rt o n
S p ri n g s
R o a d
S u it e
A u st in Te xa s
B ro a d w a y S u it e
S a n A n to n io
Te xa s
F a n in S tr e e t, S u it e
H o u st o n Te xa s p
.4
.7 f
.4
.7 p
.2
.6 f
.2
.6 p
.4
.1 f
.4
.1
1243336
04/11/24
C U s e rs \M a ri s e la
\D o c u m e n ts \3
S
C U
C
IS
D C le m e n s H
S C a fe te ri a R e n o v (C e n tr a l)
S m a ri s e la m
.r v t
/1
/2
:0
:4
P
M
04/11/2024
Project No. 1403.18
CONTRACT DOCUMENTS
SECTIONS AND DETAILS
S3.1
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
C L
E M
E N
S H
S C
A F
E T
E R
IA
S
E R
V
IN
G L
IN
E
R E
N O
V A
T
IO
N
E
LB
E L
R O
A D
S C
H E R
TZ
TE
X A
S
S C
U C
I N
D E P
E N
D E N
T S C
H O
O L
D
IS
TR
IC
T
SCALE: 3/4" = 1'-0"
1 TYPICAL DETAIL AT FILLED OPENING
SCALE: 3/4" = 1'-0"
TYPICAL DETAIL AT FILLING
EXISTING OPENING IN SLAB SCALE: 3/4" = 1'-0"
3 TYPICAL DETAIL AT NEW PENETRATION IN SLAB
SCALE: 1 1/2" = 1'-0"
4 BASE PLAN DETAIL AT SNACK BAR
SCALE: 1 1/2" = 1'-0"
5 BASE PLAN DETAIL AT CAFETERIA
NO SCALE
6 PLAN DETAIL AT MASONRY WALL
SCALE: 1/2" = 1'-0"
7 SECTION AT SNACK BAR
SCALE: 1/2" = 1'-0"
8 SECTION AT CAFETERIA
SCALE: 1 1/2" = 1'-0"
9 SECTION
SCALE: 1 1/2" = 1'-0"
10 SECTION
SCALE: 1 1/2" = 1'-0"
11 PLAN DETAIL
SCALE: 1 1/2" = 1'-0"
12 PLAN DETAIL
SCALE: 1 1/2" = 1'-0"
13 PLAN DETAIL
SCALE: 1 1/2" = 1'-0"
14 PLAN DETAIL
SCALE: 1 1/2" = 1'-0"
15 SECTION
F1 F2 F3 F4 F5 F6 F7
T.O.STL EL=
13'-11 3/4"
EXIST
CONC FLR
SLAB
10'-8" 12'-0" 8'-4" 8'-4" 12'-0" 8'-8"
22'-8" 16'-8" 20'-8"
60'-0"
S3.1
S3.1
S3.1 HSS6x4x3/16 (LSH) HSS6x4x3/16 (LSH) HSS6x4x3/16 (LSH)
H S S x x /1
T Y P
IC
A L
H S S x x /1
T Y P
IC
A L
NOTE:
3x3 COILING DOOR SUPPORT
COLUMNS TO CONNECT TO
UNDERSIDE OF HSS6x3 BEAM
S3.1
9 TYP
F8 F9 F10 F11 25'-9"
5'-0" 15'-9" 5'-0"
T.O.STL EL=
12'-7"
EXIST
CONC FLR
SLAB
H S S x x /1
T Y P
IC
A L
S3.1
9 TYP
S3.1
S3.1
HSS6x4x3/16 (LSH) HSS6x4x3/16 (LSH) HSS6x4x3/16 (LSH)
OPTIONAL
OPTIONAL
JOSEPH H. HUIZAR
87226
1045 CENTRAL PARKWAY NORTH, SUITE 200
210.349.9098
SAN ANTONIO, TEXAS 78232
TBPE FIRM F-432IES JOB NO:
ENGINEERING COMMUNITIES FROM THE GROUND UP
ie-services.com
Revisions:
A u st in
S a n A n to n io
H o u s to n
B a rt o n
S p ri n g s
R o a d
S u it e
A u st in Te xa s
B ro a d w a y S u it e
S a n A n to n io
Te xa s
F a n in S tr e e t, S u it e
H o u st o n Te xa s p
.4
.7 f
.4
.7 p
.2
.6 f
.2
.6 p
.4
.1 f
.4
.1
1243336
04/11/24
C U s e rs \M a ri s e la
\D o c u m e n ts \3
S
C U
C
IS
D C le m e n s H
S C a fe te ri a R e n o v (C e n tr a l)
S m a ri s e la m
.r v t
/1
/2
:0
:4
P
M
04/11/2024
Project No. 1403.18
CONTRACT DOCUMENTS
ELEVATIONS
S3.2
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
O
'C O
N N
E
LL
R O
B E R
TS
O
N
IN
C
C L
E M
E N
S H
S C
A F
E T
E R
IA
S
E R
V
IN
G L
IN
E
R E
N O
V A
T
IO
N
E
LB
E L
R O
A D
S C
H E R
TZ
TE
X A
S
S C
U C
I N
D E P
E N
D E N
T S C
H O
O L
D
IS
TR
IC
T
SCALE: 3/8" = 1'-0"
2 CAFETERIA SERVING ELEVATION
SCALE: 3/8" = 1'-0"
1 SNACK BAR ELEVATION
COUNTER MOUNTED DROP-IN SINK
COUNTER MOUNTED UNDER
MOUNT SINK
COUNTER MOUNTED INTEGRAL
SINK
WALL MOUNTED SINK
ACCESSIBLE LOCATION
NON-ACCESSIBLE LOCATION
CHILD…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .