ESBD_528064_1781646590095_04 - Plans.pdf
PDF 4 MB Posted
- Solicitation number
- ITB26-19725-KM
- Issued by
- Hunt County, Texas
About this file
This is a set of architectural plans and specifications for the City of Lubbock, Texas, prepared by KWA Engineering & Building Science Company, Inc., for building envelope improvements to the Traffic & Street Signs Maintenance Facility located at 202 N. Ash Avenue, Lubbock, Texas. The project encompasses improvements to a 7,116 square foot facility and includes a base bid for roof removal and replacement, with three additional alternates: removal and replacement of exterior doors and windows (Alternate No. 1), removal and replacement of exterior CMU masonry coating (Alternate No. 2), and removal and replacement of metal R-panel roofing on a shed structure designated as Area M1 (Alternate No. 3). The project is classified as building envelope improvements and will not alter the building's occupancy group, construction type, or conditioned/occupied square footage. The plans were issued for permit and bidding on May 28, 2026, with construction to follow applicable 2021 International Energy Conservation Code, 2021 International Building Code, 2021 International Plumbing Code, 2021 International Mechanical Code, 2020 National Electrical Code, and 2021 Existing Building Code standards.
The project documents include detailed roof plans identifying five distinct roof areas (A, B, C, D, and M1 shed), exterior elevations, door and window schedules with specifications for hollow metal frames and aluminum-framed fixed windows, and comprehensive flashing and roofing system details. The base bid roof work involves removal of existing two-ply modified bitumen membrane and installation of new 80-mil fleeceback thermoplastic membrane with coverboard as specified, with tapered insulation to achieve positive drainage. Additional work includes disconnection and reconnection of rooftop equipment, relocation of piping and conduit, repair of roof penetrations, installation of metal flashing, and coordination of mechanical and electrical systems. All contractors are required to verify dimensions through field measurements, protect existing structures and utilities, provide photographic documentation of pre-existing conditions, and properly dispose of construction debris off-site. The plans specify use of fire-retardant treated wood nailers, continuous flashing with specific height requirements, and adherence to detailed construction specifications for all building envelope components.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ESBD_528064_1781646514870_01 - ITB 26-19725-KM.pdf | ||
| ESBD_528064_1781646554388_03 - Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION MAP (NTS) PROJECT AERIAL (NTS)
BUILDING ENVELOPE IMPROVEMENTS PROJECT
CODE DATA
THE PROJECT CONSISTS OF BUILDING ENVELOPE
IMPROVEMENTS AS PER THESE DRAWINGS AND
SPECIFICATIONS.
BASE BID: REMOVE & REPLACE ROOF
ALTERNATE NO. 1: REMOVE & REPLACE EXTERIOR DOORS
& WINDOWS
ALTERNATE NO. 2: REMOVE & REPLACE EXTERIOR CMU
MASONRY COATING
ALTERNATE NO. 3: REMOVE & REPLACE METAL R-PANEL
ROOF ON SHED (AREA "M1")
CLASSIFICATION OF WORK : BUILDING ENVELOPE IMPROVEMENTS
BUILDING SIZE: 7,116 SQ FT±
THESE RENOVATIONS WILL NOT CHANGE THE OCCUPANCY GROUP OR
CONSTRUCTION TYPE WITHIN THE EXISTING BUILDING, OR DO THEY
CHANGE THE SQUARE FOOTAGE CONDITIONED NOR OCCUPIED SPACES.
GENERAL
G1.01____________________COVER & INDEX
ENGINEERING / ROOFING
R1.01____________________ SITE PLAN
R1.02____________________ ROOF PLAN
R1.03____________________ EXTERIOR ELEVATIONS & SCHEDULES
R2.01____________________ DETAILS
JURISDICTION: CITY OF LUBBOCK, LUBBOCK COUNTY, TEXAS
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL MECHANICAL CODE
2020 NATIONAL ELECTRICAL CODE
2021 EXISTING BUILDING CODE
PROJECT SUMMARY BUILDING CLASSIFICATION
TRAFFIC / STREET SIGNS MAINTENANCE BUILDING
TRAFFIC & STREET SIGNS MAINTENANCE FACILITY
LUBBOCK, TEXAS
INDEX OF SHEETS
N
ENGINEERING & BUILDING
SCIENCE COMPANY, INC.
F-21802
4203 N. CR 1765 LUBBOCK, TX 79401
THIS DOCUMENT AND ITS CONTENTS ARE
THE INTELLECTUAL PROPERTY OF KWA
ENGINEERING & BUILDING SCIENCE CO., INC.
(KWA) AND ARE SAFEGUARDED BY THE
FEDERAL COPYRIGHT ACT. IN NO EVENT
SHALL THE CLIENT, CONTRACTOR, OR ANY
OTHER ENTITY COPY OR USE ANY PART
OF IT FOR ANY OTHER PURPOSE OR IN
RELATION TO ANY PROJECT OTHER THAN
THE PROJECT FOR WHICH IT WAS ISSUED
WITHOUT THE PRIOR WRITTEN CONSENT
OF KWA AND THE PROFESSIONAL
ENGINEER OR ARCHITECT WHOSE SIGNED
AND DATED SEAL IT BEARS.
COVER & INDEX
DATE:
KWA FILE NO.:
REVISIONS:
# DATE DESCRIPTION
G1.01
MAY-28-2026
10007-25-13
5/28/26
TRAFFIC / STREET SIGNS MAINTENANCE BUILDING
BU
IL
D
IN
G E
N
VE
LO
PE
IM
PR
O
VE
M
EN
TS
P
R O
JE
C
T C
IT
Y
O F
LU
BB
O C
K
TR
AF
FI
C
S
TR
EE
T
SI
G
N S
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
N
. A
SH
A
VE
, L U
BB
O
C K
TE
XA
S
ISSUE SET: PERMIT + BID
DATE : 05/28/2026
THIS DOCUMENT AND ITS CONTENTS ARE
THE INTELLECTUAL PROPERTY OF KWA
ENGINEERING & BUILDING SCIENCE CO., INC.
(KWA) AND ARE SAFEGUARDED BY THE
FEDERAL COPYRIGHT ACT. IN NO EVENT
SHALL THE CLIENT, CONTRACTOR, OR ANY
OTHER ENTITY COPY OR USE ANY PART
OF IT FOR ANY OTHER PURPOSE OR IN
RELATION TO ANY PROJECT OTHER THAN
THE PROJECT FOR WHICH IT WAS ISSUED
WITHOUT THE PRIOR WRITTEN CONSENT
OF KWA AND THE PROFESSIONAL
ENGINEER OR ARCHITECT WHOSE SIGNED
AND DATED SEAL IT BEARS.
DATE:
R1.01
5/28/26
SITE PLAN
BU
IL
D
IN
G E
N
VE
LO
PE
IM
PR
O
VE
M
EN
TS
P
R O
JE
C
T C
IT
Y
O F
LU
BB
O C
K
TR
AF
FI
C
S
TR
EE
T
SI
G
N S
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
N
. A
SH
A
VE
, L U
BB
O
C K
TE
XA
S
KWA FILE NO.: 10007-25-13
ENGINEERING & BUILDING
SCIENCE COMPANY, INC.
F-21802
4203 N. CR 1765 LUBBOCK, TX 79401
N
ROOF AREA
"A"
ROOF AREA
"B" ROOF AREA
"C"
ROOF AREA
"D"
ROOF AREA
"M1"
REVISIONS:
# DATE DESCRIPTION
MAY-28-2026
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
G
AS
G
AS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
GASGASGASGASGASGASGAS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
GAS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
GAS
G
AS
G
AS
G
AS
G
AS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
G
AS
THIS DOCUMENT AND ITS CONTENTS ARE
THE INTELLECTUAL PROPERTY OF KWA
ENGINEERING & BUILDING SCIENCE CO., INC.
(KWA) AND ARE SAFEGUARDED BY THE
FEDERAL COPYRIGHT ACT. IN NO EVENT
SHALL THE CLIENT, CONTRACTOR, OR ANY
OTHER ENTITY COPY OR USE ANY PART
OF IT FOR ANY OTHER PURPOSE OR IN
RELATION TO ANY PROJECT OTHER THAN
THE PROJECT FOR WHICH IT WAS ISSUED
WITHOUT THE PRIOR WRITTEN CONSENT
OF KWA AND THE PROFESSIONAL
ENGINEER OR ARCHITECT WHOSE SIGNED
AND DATED SEAL IT BEARS.
DATE:
R1.02
5/28/26
ROOF PLAN
GAS GAS GAS
BU
IL
D
IN
G E
N
VE
LO
PE
IM
PR
O
VE
M
EN
TS
P
R O
JE
C
T C
IT
Y
O F
LU
BB
O C
K
TR
AF
FI
C
S
TR
EE
T
SI
G
N S
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
N
. A
SH
A
VE
, L U
BB
O
C K
TE
XA
S
KWA FILE NO.: 10007-25-13
ENGINEERING & BUILDING
SCIENCE COMPANY, INC.
F-21802
4203 N. CR 1765 LUBBOCK, TX 79401
N X / Y
HVAC UNIT
ROOF LEGEND
MECHANICAL VENT
CURB
ROOF HATCH
ROOF DRAIN
OVERFLOW ROOF
DRAIN
PLUMBING VENT
PITCH PAN
SKY LIGHT
ANTENNA
SATELLITE DISH
HOT STACK OR
HEATER VENT
MECHANICAL EQUIP.
ON STANDS
VENT STACK
THROUGH WALL
SCUPPER
OVER FLOW
SCUPPER
ABANDONED CURB
DUCT PENETRATION
GOOSENECK
LADDER
ROOF DRAIN +
OVERFLOW DRAIN
MECHANICAL WALL
PERIMETER SAFETY
GUARDRAIL
-DS-
DOWN SPROUT
GAS LINE
CONDUIT LINE
-RW-
RISE WALL
-ME-
METAL EDGE
-ME/G-
METAL EDGE/
GUTTER
-RME-
RAISED METAL
EDGE
-EJ-
EXPANSION JOINT
-RWEJ-
RISE WALL
EXPANSION JOINT
PARAPET WALL
NOT IN CONTRACT
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
R2.01
ME / G
ME / G
ME / G
RW
RW RW
EJ EJ
ME
ME
ME ME
ME
ME
ME
ME
RW
ME
ME
ME
R2.01
R2.01
ME
R2.01
R2.01
ROOF AREA
"A"
ROOF AREA
"B"
ROOF AREA
"C"
ROOF AREA
"D"
PROVIDE ROOF OVERLAY ROOFING SYSTEM
PROVIDE PRE-FINISHED METAL EDGE
PROVIDE PRE-FINISHED METAL GUTTER AND DOWNSPOUT
PROVIDE NEW ROLLER SUPPORTS FOR EXISTING PIPING ABOVE ROOF, REFER TO 7/R2.01
PROVIDE ROOF TO RISE WALL EXPANSION JOINT FLASHING AS DETAILED
RELOCATE OR OFFSET EXISTING ELECTRICAL SERVICE AWAY FROM BUILDING FASCIA
REMOVE AND REPLACE EXISTING R PANEL ROOFING SYSTEM ON SHED
GENERAL NOTES
A CONTRACTOR SHALL VERIFY ALL DIMENSIONS & EXAMINE ALL EXISTING SITE CONDITIONS
PRIOR TO COMMENCEMENT OF WORK AND IMMEDIATELY REPORT ANY QUESTIONABLE OR
CONFLICTING CONDITIONS.
B ALL PROSPECTIVE BIDDERS SHALL VISIT THE PROJECT SITE AND THOROUGHLY FAMILIARIZE
THEMSELVES WITH CONDITIONS AND FACTORS THAT MAY AFFECT THEIR BIDS.
C FIELD MEASUREMENTS ARE REQUIRED FOR BIDDING PURPOSES.
D IF DISCREPANCIES APPEAR BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE
HIGHER QUALITY, QUANTITY, AND PRICE SHALL SUPERSEDE.
E THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BECOME FAMILIAR WITH THE
PROJECT AND THE ON-SITE / OFF-SITE CONDITIONS PRIOR TO BIDDING OR COMMENCING
WORK.
F CONTRACTOR IS RESPONSIBLE FOR THE SAFETY, ACTIONS AND CONDUCT OF HIS
EMPLOYEES AND HIS SUBCONTRACTORS EMPLOYEES WHILE IN THE PROJECT AREA.
ADJACENT AREAS AND IN THE BUILDING AND ITS VICINITY.
G PROTECT ALL EXISTING STRUCTURES, UTILITIES, PAVING, SIDEWALKS, LANDSCAPING, ETC.
AS REQUIRED; THE CONTRACTOR IS SOLELY RESPONSIBLE TO REPAIR OR REPLACE ANY
DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES WITHOUT ADDITIONAL COMPENSATION;
PROVIDE PHOTOGRAPHIC DOCUMENTATION OF ANY PRE-EXISTING DAMAGE PRIOR TO
COMMENCEMENT OF WORK.
H PROVIDE ALL NECESSARY SIGNS & BARRICADES FOR PROTECTION OF THE WORK AND FOR
PUBLIC SAFETY.
I CONSTRUCTION DEBRIS FROM THIS PROJECT BECOMES PROPERTY OF THE CONTRACTOR
AND MUST BE PROPERLY DISPOSED OFF-SITE, UNLESS NOTED OTHERWISE.
J PERFORM WORK IN SUCH A MANNER TO MINIMIZE IMPACT TO ADJACENT FACILITIES,
STRUCTURES & IMPROVEMENTS.
K ALL WOOD BLOCKING AT ROOF EDGES ARE TO BE FABRICATED FROM CONT. 2X6
FIRE-RETARDANT TREATED WOOD BOARDS. PROVIDE LARGER 2X FIRE-RETARDANT
TREATED WOOD AS REQUIRED PER DIMENSIONED DETAIL OR AS FIELD CONDITIONS
DICTATE. ALL COPING TO BE MINIMUM SLOPE TOWARD THE INTERIOR.
L HEIGHT OF ALL NAILERS SHALL BE FLUSH WITH NEW INSULATION THICKNESS.
M ALL VERTICAL MEMBRANE FLASHING SHALL BE MECHANICALLY FASTENED AND INSTALLED
WITH NEW METAL COUNTER FLASHING UTILIZING A CONTINUOUS CLIP. SLIDE METAL COVER
PLATE DOWN OVER VERTICAL CLIP AND SEAL.
N ALL THROUGH WALL FLASHING SYSTEMS TO ACCOMMODATE 8" MINIMUM FLASHING HEIGHT
FROM FINISHED ROOF SURFACE. PROVIDE END DAMS AS CONDITIONS ALLOW. ALL FLASHING
TO HAVE 4" LAP MINIMUM AND / OR STEP.
O ANY CRACKS OR VOIDS IN RISE WALLS ABOVE COUNTER FLASHING SHALL BE REPAIRED
WITH COMPATIBLE SEALANT.
P CRICKETS / SADDLES SHALL BE TWICE THE ADJACENT ROOF SLOPE.
Q PROVIDE TAPERED CRICKETS ON HIGH SIDE OF CURBED PENETRATIONS AS REQUIRED TO
DIRECT DRAINAGE AROUND PENETRATION.
R ROOF SLOPES SHOWN ARE SCHEMATIC AND INDICATE DESIGN INTENT ONLY. TAPERED
INSULATION IS ILLUSTRATED DIAGRAMMATICALLY AND IS NOT TO SCALE. PROVIDE TAPERED
INSULATION AS REQUIRED TO ACHIEVE POSITIVE DRAINAGE TO ALL ROOF DRAINS AND
OVERFLOW SCUPPERS. VERIFY INSULATION LAYOUT, THICKNESSES, AND SLOPES IN SHOP
DRAWINGS PRIOR TO INSTALLATION.
S CONTRACTOR SHALL VERIFY OPERATIONAL STATUS OF ROOF TOP EQUIPMENT W/ OWNER
PRIOR TO COMMENCING WITH THE WORK.
T ABANDONED EQUIPMENT AND CURBS SHALL BE REMOVED FROM THE BUILDING, AND
PROPERLY DISPOSED. REPAIR DECKING AT ABANDONED PENETRATIONS. (NOT SCHEDULED
ON DRAWINGS FOR REMOVAL) PER UNIT PRICING, DETAILS AND SPECIFICATIONS.
U EXISTING GAS, CONDENSATE, ELECTRICAL, HYDRONIC PIPING, ETC. SHALL BE
DISCONNECTED, RAISED AND RECONNECTED AS REQUIRED TO ACCOMMODATE NEW ROOF
SYSTEM THICKNESS AND MEMBRANE FLASHING HEIGHT REQUIREMENTS. COORDINATE
LOCATIONS TO PREVENT CONFLICT WITH MECHANICAL UNIT SERVICE.
V ALL EQUIPMENT CURBS TO BE RAISED AS NECESSARY TO MAINTAIN 10" MINIMUM HEIGHT
ABOVE FINISHED ROOF SURFACE.
W EXISTING ROOFTOP EQUIPMENT SHALL BE DISCONNECTED RAISED AND RECONNECTED AS
REQUIRED TO PROVIDE MEMBRANE BASE FLASHING HEIGHTS SPECIFIED.
X EXISTING EQUIPMENT SUPPORT CURBS INSTALLED PERPENDICULAR TO ROOF/DRAINAGE
SLOPE SHALL BE ROTATED PARALLEL TO THE ROOF SLOPE TO PROVIDE POSITIVE
DRAINAGE DISCONNECT, MODIFY / REROUTE PIPING / CONDUIT AS REQUIRE TO RELOCATE
UNITS AND ELECTRICAL DISCONNECT BOXES.
Y ALL PITCH PANS SHALL BE SOLDERED AND RECEIVE EITHER MECHANICALLY ATTACHED
GOOSENECK OR METAL BONNETS. METAL BONNETS SHALL BE SECURED WITH CLAMPING
RING AND SEALANT. SPECIAL CARE GIVEN TO WASH ALL METAL PRIOR TO INSTALLATION.
Z ALL INFIELD EXPANSION JOINTS SHALL HAVE LOW SLOPED STANDING SEAM JOINTS AND
SHALL BE CHAMFERED AT TERMINATION AT ROOF EDGE TO MEET PROFILE OF PERIMETER.
AA PRIME AND PAINT GAS LINES, COLOR AS SELECTED BY OWNER.
BB REMOVE AND REINSTALL EXISTING BUILDING LIGHTNING PROTECTION AS REQUIRED;
ENSURE A FULLY FUNCTIONING SYSTEM.
NTSNTS
R2.01
R2.01
DS
DSDS
DSDSDS
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
SL
O
PE
KEYED NOTES DESIGNATED BY AND
ROOF PLAN NOTES
EXISTING ROOF ASSEMBLY SCHEDULE NEW ROOF ASSEMBLY SCHEDULE
EXISTING 2-PLY
MODIFIED BITUMEN
EXISTING TAPERED
PERLITE INSULATION
EXISTING 2"
POLYISOCYANURATE
INSULATION
EXISTING METAL
DECK
EXISTING 2-PLY
MODIFIED BITUMEN
EXISTING TAPERED
PERLITE INSULATION
EXISTING 2"
POLYISOCYANURATE
INSULATION
EXISTING METAL
DECK
NEW COVERBOARD
AS SPECIFIED
NEW 80-MIL
FLEECEBACK
THERMOPLASTIC
MEMBRANE
EXISTING 2-PLY
MODIFIED BITUMEN
EXISTING 3/4" PERLITE
INSULATION
EXISTING 2"
POLYISOCYANURATE
INSULATION
EXISTING METAL
DECK
EXISTING 2-PLY
MODIFIED BITUMEN
EXISTING 3/4" PERLITE
INSULATION
EXISTING 2"
POLYISOCYANURATE
INSULATION
EXISTING METAL
DECK
NEW COVERBOARD
AS SPECIFIED
NEW 80-MIL
FLEECEBACK
THERMOPLASTIC
MEMBRANE
EXISTING 2-PLY
MODIFIED BITUMEN
EXISTING 3/4" PERLITE
INSULATION
EXISTING METAL
DECK
EXISTING 2-PLY
MODIFIED BITUMEN
EXISTING 3/4" PERLITE
INSULATION
EXISTING METAL
DECK
NEW COVERBOARD
AS SPECIFIED
NEW 80-MIL
FLEECEBACK
THERMOPLASTIC
MEMBRANE
AREAS: A & D
AREA: B
AREA: C
AREAS: A & D
AREA: B
AREA: C
ROOF PLAN - AREAS "A", "B", "C" & "D"
ROOF AREA
"M1"
R-PANEL SHED
DS
DS
REVISIONS:
# DATE DESCRIPTION
MAY-28-2026
T R A F F I C M A I N T E N A N C E B L D G 2
TRAFFIC SIGNALS
6 64
1 1
8 51
0' - 0"
A A A A A A A A
B B
4 3 2 1
7 6
10 5
10' - 8" (VERIFY)
13' - 0" (VERIFY)
17'-3" (VERIFY) 23'-10" (VERIFY) 30'-7" (VERIFY)
71'-8" (VERIFY)
10' - 8" (VERIFY)
54'-2" (VERIFY) 73'-10" (VERIFY) 38'-6" (VERIFY)
166'-6" (VERIFY)
0' - 0"
12' - 2" (VERIFY)
13' - 0" (VERIFY)
13' - 0" (VERIFY)
27'-1" (VERIFY) 25'-8" (VERIFY) 18'-11" (VERIFY)
71'-8" (VERIFY)
0' - 0"
12' - 0" (VERIFY)
14' - 0" (VERIFY)
11' - 4" (VERIFY)
38'-7" (VERIFY) 46'-11" (VERIFY) 54'-2" (VERIFY)
166'-6" (VERIFY)
26'-10" (VERIFY)
0' - 0"
10' - 8" (VERIFY)10' - 8" (VERIFY)
13' - 0" (VERIFY)
14' - 0" (VERIFY)
15B/R2.01
15A/R2.01
15C/R2.01
15B/R2.01 O.H.
15B/R2.01
15A/R2.01
15C/R2.01
15B/R2.01 O.H.
ELEVATIONS
BU
IL
D
IN
G E
N
VE
LO
PE
IM
PR
O
VE
M
EN
TS
P
R O
JE
C
T C
IT
Y
O F
LU
BB
O C
K
TR
AF
FI
C
S
TR
EE
T
SI
G
N S
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
N
. A
SH
A
VE
, L U
BB
O
C K
TE
XA
S
KWA FILE NO.: 10007-25-13
ENGINEERING & BUILDING
SCIENCE COMPANY, INC.
F-21802
4203 N. CR 1765 LUBBOCK, TX 79401
N
THIS DOCUMENT AND ITS CONTENTS ARE
THE INTELLECTUAL PROPERTY OF KWA
ENGINEERING & BUILDING SCIENCE CO., INC.
(KWA) AND ARE SAFEGUARDED BY THE
FEDERAL COPYRIGHT ACT. IN NO EVENT
SHALL THE CLIENT, CONTRACTOR, OR ANY
OTHER ENTITY COPY OR USE ANY PART
OF IT FOR ANY OTHER PURPOSE OR IN
RELATION TO ANY PROJECT OTHER THAN
THE PROJECT FOR WHICH IT WAS ISSUED
WITHOUT THE PRIOR WRITTEN CONSENT
OF KWA AND THE PROFESSIONAL
ENGINEER OR ARCHITECT WHOSE SIGNED
AND DATED SEAL IT BEARS.
DATE:
R1.03
5/28/26
X / Y
GENERAL NOTES
A VERIFY ALL DIMENSIONS & EXAMINE ALL EXISTING SITE
CONDITIONS PRIOR TO COMMENCEMENT OF WORK AND
IMMEDIATELY REPORT ANY QUESTIONABLE OR
CONFLICTING CONDITIONS TO THE ARCHITECT AT
806-775-2368
B THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS,
METHODS, TECHNIQUES & SAFETY PRECAUTION PROGRAMS
RELATING IN ANY WAY TO THE CONDITIONS OF THE
PREMISES
C PROTECT ALL EXISTING STRUCTURES, UTILITIES, PAVING,
SIDEWALKS, LANDSCAPING, ETC. AS REQUIRED; THE
CONTRACTOR IS SOLELY RESPONSIBLE TO REPAIR OR
REPLACE ANY DAMAGE CAUSED BY CONSTRUCTION
ACTIVITIES WITHOUT ADDITIONAL COMPENSATION; PROVIDE
PHOTOGRAPHIC DOCUMENTATION OF ANY PRE-EXISTING
DAMAGE PRIOR TO COMMENCEMENT OF WORK
D PROVIDE ALL NECESSARY SIGNS & BARRICADES FOR
PROTECTION OF THE WORK AND FOR PUBLIC SAFETY
E PROTECT ALL EXISTING INTERIOR FINISHES, EQUIPMENT,
CONSTRUCTION, ETC. TO REMAIN
F CONSTRUCTION DEBRIS FROM THIS PROJECT BECOMES
PROPERTY OF THE CONTRACTOR AND MUST BE PROPERLY
DISPOSED OFF-SITE, UNLESS NOTED OTHERWISE
G PERFORM WORK IN SUCH A MANNER TO MINIMIZE IMPACT
TO ADJACENT FACILITIES, STRUCTURES & IMPROVEMENTS
H REMOVE ALL ITEMS SHOWN DASHED, INCLUDING BUT NOT
LIMITED TO, PLUMBING, MECHANICAL & ELECTRICAL ITEMS;
RELOCATE ANY ITEMS SPECIFICALLY NOTED; RETURN
SALVAGEABLE ITEMS TO OWNER
I PATCH/REPAIR ALL EXISTING SUBSTRATES AT DEMOLITION
ACTIVITY AS REQUIRED, TO RECEIVE NEW FINISHES
KEYED NOTES DESIGNATED BY AND
EXISTING BUILDING SIGNAGE, LIGHT FIXTURES, AND
ELECTRICAL BOXES TO REMAIN, PROTECT AS REQUIRED
EXISTING STEEL BOLLARD TO REMAIN, PAINT
EXISTING INTAKE LOUVER TO REMAIN, PAINT
EXISTING EQUIPMENT TO REMAIN
REMOVE & REPLACE EXISTING STORAGE RACK, BY OWNER
REMOVE & REPLACE EXISTING GUTTERS, DOWNSPOUTS
AND METAL EDGE
REMOVE & REPLACE EXISTING HVAC EVAPORATIVE UNIT
HOUSING WITH PRE-FINISHED, INSULATED METAL,
RE-INSTALL UNIT
REWORK EXISTING BUILDING ELECTRICAL SERVICE TO
AVOID CONFLICT WITH ROOF METAL EDGE
EXISTING SHED TO REMAIN, PAINT
REMOVE EXISTING ROOF TOP EXHAUST FAN, CAP CURB
WEATHERTIGHT
WINDOW AND DOOR DEMOLITION, ASBESTOS ABATEMENT
AND TEMPORARY CONSTRUCTION UNDER SEPARATE
CONTRACT, TYPICAL; COORDINATE NEW WINDOW AND
DOOR INSTALLATION WITH ABATEMENT CONTRACTOR.
ELEVATION NOTES
NTSNTS
EAST ELEVATION
NTSNTS
NORTH ELEVATION
NTSNTS
WEST ELEVATION
NTSNTS
SOUTH ELEVATION
REVISIONS:
# DATE DESCRIPTION
MAY-28-2026
ISSUE SET: PERMIT + BID
DATE : 05/28/2026
AutoCAD SHX Text
DOOR TYPE ELEVATIONS
AutoCAD SHX Text A
AutoCAD SHX Text
FLUSH DOOR
AutoCAD SHX Text
DOOR FRAME TYPE ELEVATIONS
AutoCAD SHX Text A
AutoCAD SHX Text
2" HOLLOW METAL FRAME
AutoCAD SHX Text B
AutoCAD SHX Text
OVERHEAD COILING DOOR
AutoCAD SHX Text B
AutoCAD SHX Text
2" HOLLOW METAL FRAME
AutoCAD SHX Text C
AutoCAD SHX Text
2" HOLLOW METAL FRAME
AutoCAD SHX Text D
AutoCAD SHX Text
2" HOLLOW METAL FRAME
AutoCAD SHX Text E
AutoCAD SHX Text
2" HOLLOW METAL FRAME
AutoCAD SHX Text
WINDOW FRAME ELEVATIONS
AutoCAD SHX Text A
AutoCAD SHX Text
1ST FFL
AutoCAD SHX Text
ALUMINUM FRAME FIXED WINDOW
AutoCAD SHX Text B
AutoCAD SHX Text
1ST FFL
AutoCAD SHX Text
VERIFY
AutoCAD SHX Text
ALUMINUM FRAME FIXED WINDOW
AutoCAD SHX Text
VERIFY
AutoCAD SHX Text
VERIFY
AutoCAD SHX Text
VERIFY
AutoCAD SHX Text
DOOR SCHEDULE
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
FRAME
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
HARDWARE SET
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
MARK
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
CONST
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
CONST
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
SILL
AutoCAD SHX Text
AutoCAD SHX Text 36x80
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 5 34
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 12/R2.01
AutoCAD SHX Text 13/R2.01
AutoCAD SHX Text 14/R2.01
AutoCAD SHX Text
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
AutoCAD SHX Text 48x80
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 5 34
AutoCAD SHX Text C
AutoCAD SHX Text
HM
AutoCAD SHX Text 12/R2.01
AutoCAD SHX Text 13/R2.01
AutoCAD SHX Text 14/R2.01
AutoCAD SHX Text
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
AutoCAD SHX Text 36x80
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 5 34
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 12/R2.01
AutoCAD SHX Text 13/R2.01
AutoCAD SHX Text 14/R2.01
AutoCAD SHX Text
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
AutoCAD SHX Text 42x80
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 5 34
AutoCAD SHX Text B
AutoCAD SHX Text
HM
AutoCAD SHX Text 12/R2.01
AutoCAD SHX Text 13/R2.01
AutoCAD SHX Text 14/R2.01
AutoCAD SHX Text
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
AutoCAD SHX Text 36x80
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 5 34
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 12/R2.01
AutoCAD SHX Text 13/R2.01
AutoCAD SHX Text 14/R2.01
AutoCAD SHX Text
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
AutoCAD SHX Text 44x84
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 5 34
AutoCAD SHX Text E
AutoCAD SHX Text
HM
AutoCAD SHX Text 12/R2.01
AutoCAD SHX Text 13/R2.01
AutoCAD SHX Text 14/R2.01
AutoCAD SHX Text
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
AutoCAD SHX Text 96x112
AutoCAD SHX Text B
AutoCAD SHX Text
ST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BY MFG
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
AutoCAD SHX Text 120x114
AutoCAD SHX Text B
AutoCAD SHX Text
ST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BY MFG
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
AutoCAD SHX Text 36x86
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 5 34
AutoCAD SHX Text D
AutoCAD SHX Text
HM
AutoCAD SHX Text 12/R2.01
AutoCAD SHX Text 13/R2.01
AutoCAD SHX Text 14/R2.01
AutoCAD SHX Text
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
AutoCAD SHX Text 36x80
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 5 34
AutoCAD SHX Text A
AutoCAD SHX Text
HM
AutoCAD SHX Text 12/R2.01
AutoCAD SHX Text 13/R2.01
AutoCAD SHX Text 14/R2.01
AutoCAD SHX Text
AutoCAD SHX Text
PAINT FRAME
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text 1 DOOR SIZE: (WxH) DOOR SIZE INDICATED IS NOMINAL. DOOR SIZE: (WxH) DOOR SIZE INDICATED IS NOMINAL. (WxH) DOOR SIZE INDICATED IS NOMINAL. (WxH) DOOR SIZE INDICATED IS NOMINAL. REDUCTION SHALL BE MADE FOR THRESHOLD & EDGE CLEARANCES. ALL DOORS ARE 1 " THICK UNLESS 34" THICK UNLESS INDICATED OTHERWISE. 2 DOOR TYPE: REFER TO DOOR TYPE ELEVATIONS DOOR TYPE: REFER TO DOOR TYPE ELEVATIONS REFER TO DOOR TYPE ELEVATIONS 3 DOOR CONSTRUCTION: DOOR CONSTRUCTION: AL - ALUMINUM - ALUMINUM ALUMINUM HM - HOLLOW METAL DOOR - HOLLOW METAL DOOR HOLLOW METAL DOOR ST - STEEL DOOR - STEEL DOOR STEEL DOOR VNYL - VINYL COVERED DOOR - VINYL COVERED DOOR VINYL COVERED DOOR HCPF - HOLLOW CORE WOOD DR, PAINT FINISH - HOLLOW CORE WOOD DR, PAINT FINISH HOLLOW CORE WOOD DR, PAINT FINISH HCTF - HOLLOW CORE WOOD DR, TRANSPARENT FINISH - HOLLOW CORE WOOD DR, TRANSPARENT FINISH HOLLOW CORE WOOD DR, TRANSPARENT FINISH SCLP - SOLID CORE WOOD DR, LAMINATED PLASTIC - SOLID CORE WOOD DR, LAMINATED PLASTIC SOLID CORE WOOD DR, LAMINATED PLASTIC VENEER SCPF - SOLID CORE WOOD DR, PAINT FINISH - SOLID CORE WOOD DR, PAINT FINISH SOLID CORE WOOD DR, PAINT FINISH SCTF - SOLID CORE WOOD DR, TRANSPARENT FINISH - SOLID CORE WOOD DR, TRANSPARENT FINISH SOLID CORE WOOD DR, TRANSPARENT FINISH 4 FRAME SIZE: SIZE INDICATED IS OVERALL FRAME DEPTH, FRAME SIZE: SIZE INDICATED IS OVERALL FRAME DEPTH, SIZE INDICATED IS OVERALL FRAME DEPTH, REFER TO DETAILS FOR PROFILE 5 FRAME TYPE: REFER TO DOOR FRAME TYPE ELEVATIONS FRAME TYPE: REFER TO DOOR FRAME TYPE ELEVATIONS REFER TO DOOR FRAME TYPE ELEVATIONS 6 FRAME CONST: AL - ALUMINUM FRAME CONST: AL - ALUMINUM AL - ALUMINUM - ALUMINUM HM - HOLLOW METAL - HOLLOW METAL ST - STEEL - STEEL WDPF - WOOD, PAINT FINISH - WOOD, PAINT FINISH WDTF - WOOD, TRANSPARENT FINISH - WOOD, TRANSPARENT FINISH 7 DETAILS: NUMBERS SHOWN ARE DETAIL & SHEET NUMBER DETAILS: NUMBERS SHOWN ARE DETAIL & SHEET NUMBER NUMBERS SHOWN ARE DETAIL & SHEET NUMBER EX.: 4/R2.01 = DETAIL 4, SHEET R2.01 8 HARDWARE SET: REFER TO DOOR HARDWARE HARDWARE SET: REFER TO DOOR HARDWARE REFER TO DOOR HARDWARE SCHEDULE 9 REMARKS: GLASS: REMARKS: GLASS: GLASS: G1 - " CLEAR, TEMPERED GLASS - " CLEAR, TEMPERED GLASS 14" CLEAR, TEMPERED GLASS G2 - " WIRED GLASS - " WIRED GLASS 14" WIRED GLASS U.L. RATING: H1 - 20 MINUTE DOOR AND FRAME - 20 MINUTE DOOR AND FRAME H2 - 1 HOUR DOOR AND FRAME - 1 HOUR DOOR AND FRAME H3 - 1 HOUR DOOR AND FRAME - 1 HOUR DOOR AND FRAME 12 HOUR DOOR AND FRAME H4 - 3 HOUR DOOR AND FRAME- 3 HOUR DOOR AND FRAME
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MEMBRANE-COATED PERIMETER
EDGE-METAL FLASHING
HOT-AIR-WELDED SEAM
EXTENDED FIELD SHEET
2 X 6 MIN. WOOD NAILER
ATTACHED TO SUBSTRATE¾
OVERALL THICKNESS TO
MATCH INSULATION
HOT-AIR-WELDED
MEMBRANE FLASHING
APPROX. 3"
WOOD NAILER AND
SHEET-METAL CLOSURE
BONDING
ADHESIVE
SEALANT
NOT TO SCALE
DRAINING PERIMETER EDGE METAL WITH MEBRANE COATING1
OPTIONAL: CONTINOUS
SEALANT
WOOD
NAILERS
THERMOPLASTIC
ROOF MEMBRANE
FASTENERS 3'' to 6'' [75 to 150 mm] O.C.
STAGGER
SEALANT (IF REQUIRED
FOR THE SPECIFIC
SYSTEM)
ROOF
DECK
MIN.
1/2''
OPTIONAL:
STIFFENING BAR
OPTIONAL: GUTTER
BRACKET SUPPORT
SHEET METAL
GUTTER. THE FRONT
OF THE GUTTER
SHOULD BE A MIN. 1''
[25 mm] LOWER THAN
THE BACK TO ALLOW
OVERFLOW
GUTTER SPACERS
INSTALLED BETWEEN
GUTTER BRACKETS
SHEET METAL OR
MEMBRANE COATED
METAL EDGE
FLASHING WITH 3''
[75 mm] FLANGE (AS
REQ'D FOR SPECIFIC
SYSTEM) OPTIONAL:
DRAINAGE BAR TO
RETAIN BALLAST
FLASHING MEMBRANE
2''MIN.
OPTION:
NOT TO SCALE
GUTTER2
SEALING MATERIAL
SEAM PLATES AND
FASTENERS
WOOD CURB
2 X 6 MIN. WOOD
NAILER ATTACHED TO
SUBSTRATE¾OVERALL
THICKNESS TO MATCH
INSULATION
FL
A
S H
IN
G
H E
IG
H
T 8'
' M
IN
IM
U
M
HOT-AIR-WELDED SEAM
BONDING ADHESIVE
SEALANT (IF REQUIRED FOR
THE SPECIFIC SYSTEM)
GASKETED FASTENERS¾MIN.
TWO FASTENERS PER SIDE
ROOFTOP EQUIPMENT
FRAME
SECTION
FLASHING MEMBRANE
WOOD CURB
FLASHING RECEIVER
1'' MINIMUM BELOW
TOP OF CURB
SEALING MATERIAL¾
MUST BE CONTINUOUS ON
TOP OF THE CURB
FASTENERS
COUNTERFLASHING
BASE OF UNIT EXTENDS 1/2''
MINIMUM BEYOND TOP OF
CURB
MECHANICAL UNIT, HOOD, ETC.
SHEET-METAL RECEIVER
WITH REMOVABLE
COUNTERFLASHING
ADHERED MEMBRANE
FLASHING
PREFABRICATED CORNER
FLASHING PIECE AT EACH
CORNER
NOT TO SCALE
BASE FLASHING AT WOOD CURB3
FLASHING
CONT. CLEAT
REMOVABLE SHEET METAL
COUNTERFLASHING
REGLET RECIVER
FASTENERS APPROX. 24"
O.C.
HEAD OF CANT STRIP
ROOF DECK
THERMAL INSUL.
COVERBOARD FIELD SHEET
8"
BASE SHEET AS REQUIRED
FASTENED APPROX. 8" O.C.
SEALENT
METAL PANEL SYSTEM
EXTEND MEMBRANE SHEET TO
OVERLAY METAL CLOSURE
COVERBOARD
EXISTING
THERMAL
INSULATION
ROOF DECK
WOOD NAILERS
CONTINUOUS 22 GA. CLEAT
FLEXIBLE MEMBRANE CLOSURE
8" CLAD METAL EDGE FLASHING
FASTENERS AT APPROX. 3" O.C.
STAGGERED
FIELD SHEET
STRIP IN PLY-HEAT WELDED TO
CLAD METAL
PREFINISHED METAL 24 GA.
4" FR PLYWOOD
NOT TO SCALE
BASE FLASHING UNDER ROOF EDGE4
2 x 6 MIN. WOOD NAILER
ATTACHED TO SUBSTRATE¾
OVERALL THICKNESS TO
MATCH INSULATION
TOP OF CURB TO
DRAIN TO ONE SIDE
COMPRESSIBLE
INSULATION
FLEXIBLE LINER TO SERVE AS
INSULATION RETAINER
(ATTACHED TO TOP OF CURB)
FL
A
S H
IN
G
H E
IG
H
T 8'
' M
IN
IM
U
M
O N
L O
W S
ID
E
SEAM PLATES AND
FASTENERS
SEALANT (IF REQUIRED FOR
THE SPECIFIC SYSTEM)
ADHERED MEMBRANE
FLASHING
FLEXIBLE WEATHERPROOF
MEMBRANE CLOSURE
SHEET-METAL EXPANSION JOINT
COVER WITH T-TYPE CLEAT
SLOPE
HOT-AIR-WELDED SEAM
BONDING ADHESIVE
NOT TO SCALE
BASE FLASHING AT EXPANSION JOINT WITH METAL COVER5
WOOD NAILER
MULTIPLE-PLY MEMBRANE
BASE FLASHING
THERMAL INSULATION
COVERBOARD INSULATION
MULTIPLE-PLY BUILT-UP
ROOF MEMBRANE
ROOF DECK
FASTENERS APPROX. 8''
[200 mm] O.C.
GASKETED FASTENERS
MINIMUM TWO FASTENERS
PER SIDE
[100 mm]
APPROX. 4''
METAL CAP
PEAL AND STICK MEMBRANE
4" FR TREATED PLYWOOD
GYPSUM SHEATHING
4" FR TREATED
PLYWOOD
INSULATION R-30
PREMANUFACTURED
MEMBRANE FLASHING
INSTALL SEALANT OR
SEALANT TAPE
BETWEEN PIPE AND
PREMANUFACTURED
MEMBRANE FLASHING
PLUMBING VENT STACK
DRAWBAND
SEALANT
HOT-AIR-WELDED SEAM
BASE MEMBRANE
ATTACHMENT AS
REQUIRED FOR
SPECIFIC SYSTEM¾
SEE NOTE 3
MEMBRANE-COATED METAL
PENETRATION POCKET¾
NONSHRINK
GROUT
HOT-AIR-WELDED
MEMBRANE FLASHING
SEALANT (IF REQUIRED FOR
THE SPECIFIC SYSTEM)
SHEET-METAL RAIN COLLAR
OVERLAPPING PENETRATION
POCKET WITH APPROPRIATE
SEALANT (E.G.,
POLYURETHANE) AND
DRAWBAND
HOT-AIR-WELDED SEAM
VERIFY DEPTH
WITH SEALANT
MANUFACTURER
CROWN POURABLE
SEALANT
NOT TO SCALE
PLUMBING VENT [PREMANUFACTURED BOOT]8NOT TO SCALE
MEMBRANE-COATED METAL PENETRATION POCKET - SINGLE PENETRATION9
BASE FLASHING AT MEMBRANE-COATED SHEET-METAL HOOD FOR
PIPING THROUGH ROOF DECK
REMOVEABLE
WEATHERPROOF
SHEET-METAL PIPE
PENETRATION HOOD
SET FLANGE IN SEALANT
2 X 6 MIN. WOOD NAILER
ATTACHED TO SUBSTRATE¾
OVERALL THICKNESS TO MATCH
INSULATION
SLOPE PIPES DOWN
AND AWAY FROM
HOOD
MEMBRANE-COATED
SHEET-METAL ENCLOSURE
HOT-AIR-WELDED
MEMBRANE FLASHING
(EXTENDED APPROX.
3" BEYOND FLANGE)
INSULATE VOID (NOT
SHOWN FOR CLARITY)
MIN. TWO
FASTENERS PER SIDE
NOT TO SCALE10
WIDTH - S
EE TABLE
SEE TABLE
HEIGHT-
STRUCTURAL FRAME
SEE DETAIL TP-11 FOR
FLASHING OF
SUPPORT LEGS
ROUND PIPE COLUMN
NOT TO SCALE
EQUIPMENT SUPPORT STAND11
NOT TO SCALE
CAPPED ABANDONED CURB6NOT TO SCALE
PIPE SUPPORT7
TPO ROLLER
NOT TO SCALE
HEAD DETAIL12NOT TO SCALE
JAMB DETAIL13NOT TO SCALE
SILL DETAIL14NOT TO SCALE
WINDOW DETAILS15
CONTINOUS
WET SEAL
EXISTING CMU
CONSTRUCTION
DOOR AS
SCHEDULED
FRAME AS
SCHEDULED
DOOR AS
SCHEDULED
FRAME AS
SCHEDULED
CONTINOUS
WET SEAL
EXISTING CMU
CONSTRUCTION
DOOR AS
SCHEDULED
ALUMINUM
THRESHOLD,
SET IN MASTIC
EXPANSION
ANCHORS
EXISTING CMU
CONSTRUCTION
7/
8" 3/
8" M
O
7/ 8"
3/ 8"
M O
1 7/8"3/8"
MO
THIS DOCUMENT AND ITS CONTENTS ARE
THE INTELLECTUAL PROPERTY OF KWA
ENGINEERING & BUILDING SCIENCE CO., INC.
(KWA) AND ARE SAFEGUARDED BY THE
FEDERAL COPYRIGHT ACT. IN NO EVENT
SHALL THE CLIENT, CONTRACTOR, OR ANY
OTHER ENTITY COPY OR USE ANY PART
OF IT FOR ANY OTHER PURPOSE OR IN
RELATION TO ANY PROJECT OTHER THAN
THE PROJECT FOR WHICH IT WAS ISSUED
WITHOUT THE PRIOR WRITTEN CONSENT
OF KWA AND THE PROFESSIONAL
ENGINEER OR ARCHITECT WHOSE SIGNED
AND DATED SEAL IT BEARS.
DATE:
R2.01
5/28/26
DETAILS
BU
IL
D
IN
G E
N
VE
LO
PE
IM
PR
O
VE
M
EN
TS
P
R O
JE
C
T C
IT
Y
O F
LU
BB
O C
K
TR
AF
FI
C
S
TR
EE
T
SI
G
N S
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
N
. A
SH
A
VE
, L U
BB
O
C K
TE
XA
S
KWA FILE NO.: 10007-25-13
ENGINEERING & BUILDING
SCIENCE COMPANY, INC.
F-21802
4203 N. CR 1765 LUBBOCK, TX 79401
REVISIONS:
# DATE DESCRIPTION
MAY-28-2026
ISSUE SET: PERMIT + BID
DATE : 05/28/2026
AutoCAD SHX Text
HM DR FR
AutoCAD SHX Text
HM DR FR
AutoCAD SHX Text
A FIXED SILL
AutoCAD SHX Text
C FIXED HEAD
AutoCAD SHX Text
B FIXED JAMB
File details come from the government source that posted it. Updated .