ESBD_525722_1782240217026_Addendum No.1-Posted QA.pdf
PDF 344 KB Posted
- Attached to
- Invitation for Bids for Installation of Water Tank for San Felipe de Austin State Historic Site
- Solicitation number
- 808-26-261998
- Issued by
- Texas
About this file
Addendum No. 1 – Questions and Answers for IFB 808-26-261998
This is an Addendum No. 1 Questions and Answers document issued by the Texas Historical Commission (THC) for the Invitation for Bid (IFB 808-26-261998) regarding the installation of a water tank at San Felipe de Austin State Historic Site in San Felipe, Texas. The addendum, posted June 23, 2026, clarifies specifications for a 25,000-gallon Zincalume Silver water storage tank (Pioneer Water Storage Tank Model XLR 23/02, 26'4" diameter by 7'2" height, with 25,124 usable gallons) and associated infrastructure components including a 29' by 29' concrete structural slab with 6-inch thickness, below-grade plumbing with 100 feet of trench and 6-inch PVC piping, and equipment such as a 6-inch anti-vortex outlet, 2-inch inlet with float valve, 6-inch butterfly valve, Fire Department Connection (FDC) hardware, sacrificial anodes, roof system, and Windmaster ventilator. The equipment specifications are detailed in Section 3.B of the Scope of Work and comply with NFPA standards (NFPA 22 ed. 2018, NFPA 24 ed. 2019, and NFPA 25 ed. 2020). Mandatory pre-bid site visits are required between June 16-19, 2026, with the site located at 220 2nd Street, San Felipe, Texas 77473, operating hours Tuesday to Sunday, 9 AM to 5 PM, with site contact available at 979-885-2181 or via email at jordan.anderson@thc.texas.gov or Stephen.kelly@thc.texas.gov. A signed Site Visit Form (Exhibit X) must be included with the bid submission, or the bid will be rejected. Bids are due July 9, 2026, at 2:00 PM CT.
The addendum emphasizes that all equipment specifications, including the specific tank model, hold-down kit, inlet/outlet components, and associated hardware, are mandatory requirements outlined in the Scope of Work. Bidders must acknowledge receipt of this addendum to avoid proposal rejection. The document provides critical clarification on previously undefined specifications such as FDC hardware, which is identified as an aluminum Fire Department Connection label (18" by 9"), enabling contractors to accurately price materials and labor for the complete installation project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM 1
QUESTIONS AND ANSWERS
June 23, 2026
SOLICITATION: IFB 808-26-261998
JOB NAME: Invitation for Bid for Installation of Water Tank at San Felipe de Austin State Historic Site
CLASS/ITEM: 913-60 Construction, Water System/Plants, Main and Service Lines
1. QUESTION: On page 8 (screenshot below) under the Below Grade Plumbing section, #4 states “6" Riser with FDC hardware.” Can I get the specs on this “FDC hardware”? We are also wondering what type of tank and size you are looking for. ANSWER: All equipment is outlined in Section 3.B of the Scope of Work.
B. Equipment Requirements o Concrete Slab, 29’x29’
• 6” thick with 24” wide perimeter footing at 12” min. below grade
• 28-day compressive strength of 4,000 psf
• #4 reinforcing steel bars at 12” o.c. each way. “L” lap bars at corners
• A soils compaction report for the site is available upon request o Water Storage Tank, Useable 25,000 gallons, Zincalume Silver
• Include tank body with roof system, liner, access hatch, hold down kit, overflow, ventilator and sacrificial anodes
• 2” inlet and valve kit
• 6” ANSI anti-vortex outlet and valve kit
• Aluminum Fire Department Connection (FDC) Signage
• 20-year warranty
▪ Per NFPA 22 ed. 2018
▪ Per NFPA 24 ed. 2019
▪ Per NFPA 25 ed. 2020 o Below-grade Plumbing
• 100’ trench, line bottom of trench with ¾” stone bed
• Min. trench depth to be below local frost line
• 6” PVC pipe
• 6” Riser with FDC hardware
XLR 23/02
Pioneer Water Storage Tank, Model XLR 23/02, 26'4" D x 7'2"H, 25,124 Usable
Gallons, Zincalume Silver, Includes Tank Body, Aqualiner Fresh with Geotex Underlay, Lockable Access Hatch, Removable Ladder, 6" Overflow, Sacrificial Anodes, Roof
System, 20 Year Warranty.
XLR 23 Hold Down Kit
Hold Down Kit for Ring Beam Anchoring to Suit XL 23/02
2" Float Valve
Big Al 2 " Inlet and Float Valve
6" Galvanized Outlet with Anti Vortex Plate
6" Galvanized Outlet with Anti Vortex Plate, ANSI 150 Flange
6" Butterfly Valve
6" Butterfly Valve Kit
FDC Label
Aluminum Fire Department Connection (FDC) Label, 18"x9"
Commercial Level Gauge
Commercial Water Level Indicator - 2 Ring Tank
Windmaster Ventilator
Windmaster Ventilator
Delivery & Installation
Delivery & Installation of Fire Water Tank 1.00
2. QUESTION: We are also wondering what type of tank and size you are looking for.
ANSWER: Answer to this question is posted to question #1.
3. QUESTION: Can you please disclose the hours for the site visit and whom do we need to contact onsite once we reach there? Also, are there any requirements or instructions we need to follow during the site walk? ANSWER: The solicitation packet includes information on your question regarding the site visits.
I've also copied it below for your information.
This IFB requires a pre-bid site visit/inspection. Bidders must schedule their own site visits from June 16, 2026, to June 19, 2026. The San Felipe de Austin State Historic Site is located at San Felipe, 220 2ND Street, SanFelipe, Texas 77473.Site contact: 979-885-2181 or jordan.anderson@thc.texas.gov or
Stephen.kelly@thc.texas.gov Site Hours: Tuesday to Sunday, 9 AM – 5 PM. Respondents must schedule their visits within the specified timeframe and submit their questions by the noted deadline.
After the site visit, the Site Representative and Bidder must sign to establish the visit date. Exhibit X, Site Visit
Form, must be included in the Bid. The Bid will be rejected if a signed Site Visit Form is not included.
BID OPENING TIME: 2:00 PM CT
DATE: July 9, 2026
END OF ADDENDUM
Bidder acknowledges receipt of the following addenda: Addendum #1 __________(initial)
WARNING: BIDDER’S FAILURE TO ACKNOWLEDGE RECEIPT OF ADDENDA MAY RESULT IN
REJECTION OF THE PROPOSAL.