ESBD_395178_1739228022251_IW209163 Drawings.pdf
PDF 7 MB Posted
- Attached to
- Purchase and Installation of Water Softeners
- Solicitation number
- IW209163
- Issued by
- Schleicher County, Texas
About this file
This is a set of engineering drawings from the Texas Department of Criminal Justice (TDCJ) Engineering Service for the installation of unit-wide water softeners at the San Saba Unit in San Saba, Texas. The project (MWR #06523004) involves constructing a new 10'-6" x 25'-2" metal building to house water softener equipment, including installation of a 5" concrete slab, water softener system on a 64" x 104" skid, brine tanks, and associated plumbing and electrical work. The drawings are dated July 29, 2024 and include detailed specifications for structural components, wall systems, roofing, doors, and utilities. The building will be located adjacent to the main facility building in Sector 4.
The drawings specify construction requirements including a 5" concrete slab with vapor barrier, 6" cold-formed metal stud walls with R-13 insulation, PBR metal panel roofing with R-30 insulation, one 6'x10' hollow metal door, and one 6'x7' overhead roll-up door. The structure must meet wind design criteria for 110 MPH basic wind speed with an importance factor of 1.25 for Occupancy Category I-3. Foundation specifications require 1.50 KSF bearing capacity for continuous footings and 2.00 KSF for isolated footings. The plans include detailed requirements for concrete work, structural steel, reinforcing, and metal panel installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ESBD_395178_1739228170376_IW209163.pdf | ||
| ESBD_395178_1739228020695_Disclaimer.pdf | ||
| ESBD_395178_1739228021598_IW209163 SOW.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HUNTSVILLE, TEXAS
ENGINEERING SERVICES
M.W.R. NO. 06523004
TYLER
HUNTSVILLE
AUSTIN
SAN ANTONIO
HOUSTON
DALLAS
LUBBOCK
AMARILLO
EL PASO
LAREDO
FT. WORTH
INSTALL WATER SOFTENERS - UNIT WIDE
SAN SABA UNIT
SAN SABA COUNTY
UNIT LOCATION
SAN SABA, TEXAS
31.2003 N / -98.7623 W
SAN SABA UNIT
SNOOK
WORK SITE VIEW
STATE-WIDE VIEW
PROJECT LOCATION
THE TEXAS DEPARTMENT OF CRIMINAL JUSTICE
FACILITIES DIVISION
FORT STOCKTON
AREA VIEW
M W
R
U N
IT
S
AN
S
AB
A
PR
O
JE
C T:
I N
ST
AL
L W
AT
ER
S O
FT
EN
ER
S
- U N
IT
W
ID
E
PROJECT LOCATION
31.19986 N / -98.76275 W
D R
AW
IN
G P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G
\a ca d lib ra ry
\p ro je ct d ra w in g da ta ba se \s an s ab a
(0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C
H
S
TR
U C
T.
dw g
T H
E S
T A T E O F
T E X
A S
206 SOUTH WALLACE CREEK ROAD
SAN SABA, TEXAS 76877
SAN SABA
N
SHEET 01 OF 09
ISSUED FOR CONSTRUCTION
07/29/2024
N
SAN SABA UNIT
SAN SABA UNIT
PL
O
T D
AT
E:
7/
/2
1:
P
M D
R
AW
IN
G
P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G \a ca d lib ra ry \p ro je ct d ra w in g da ta ba se
\s an s ab a (0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C H
S
TR
U
C T.
dw g
SHEET INDEX
SHEET NAME TITLE SHEET ORDER
--- COVER 01 OF 09
A-0 STRUCTURAL NOTES 02 OF 09
A-1 SITE PLAN 03 OF 09
A-2 FLOOR PLANS 04 OF 09
A-3 ELEVATIONS 05 OF 09
A-4 SECTIONS 06 OF 09
A-5 DETAILS 07 OF 09
A-6 STANDARD DETAILS 08 OF 09
A-7 STANDARD DETAILS 09 OF 09
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text o
AutoCAD SHX Text p
AutoCAD SHX Text o
AutoCAD SHX Text o
AutoCAD SHX Text p
AutoCAD SHX Text
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text o
AutoCAD SHX Text o
AutoCAD SHX Text o
AutoCAD SHX Text o
A
N O
D
AT
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
PR
O
JE
C
T N
AM
E:
D
ES
C R
IP
TI
O N
R
EV
IS
IO
N
1 2 3 4 5 1 2
TEXAS DEPARTMENT
OF
CRIMINAL JUSTICE
ENGINEERING SERVICE
PO BOX 4011
TWO FINANCIAL PLAZA,
SUITE 400
HUNTSVILLE, TX 77340
TITLE:
M W
R
U N
IT
EN
G
IN
EE
R
D R
AW
N
B Y:
SC
AL
E:
A
S
SH
O W
N D
AT
E
SHEET OF
IN
ST
AL
L
W
AT
ER
S
O
FT
EN
ER
S
- U
N
IT
W
ID
E
TI
M
K
IE
R
SZ
, P E
SA
N
S
AB
A
B .G
O U
BE
R
T
STRUCTURAL
NOTES
A-0 02 09
/1
8/
IS
SU
ED
F O
R
FI
R
ST
T
EC
H N
IC
AL
R
EV
IE
W
C O N
ST
R U C
TI
O N
/2
9/
PL
O
T D
AT
E:
7/
/2
1:
P
M D
R
AW
IN
G
P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G \a ca d lib ra ry \p ro je ct d ra w in g da ta ba se
\s an s ab a (0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C H
S
TR
U
C T.
dw g
BRAND OR MANUFACTURER'S REFERENCES ARE DESCRIPTIVE ONLY, AND INDICATE
TYPE AND QUALITY TO BE PROVIDED. ALL REFERENCES TO BRAND OR
MANUFACTURER NAMES SHALL BE INTERPRETED TO INCLUDE THE LANGUAGE "OR
A/E APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING SPECIFICATIONS
WILL BE CONSIDERED, IRRESPECTIVE OF THE LANGUAGE "OR A/E APPROVED EQUAL"
APPEARING IN CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.
DESIGN LOAD CRITERIA
1. THE DESIGN OF THE STRUCTURE AND PARTS THEREOF IS IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING
CODE, AS ADOPTED BY TEXAS DEPARTMENT OF CRIMINAL JUSTICE.
2. ROOF LIVE LOADS:
AREA UNIFORM SPECIAL COMMENTS LIVE LOAD REDUCTION
ROOF, GENERAL 20 PSF YES, PER IBC 1607.11.2
ROOF, EQUIP. LOADS SEE ROOF PLAN
3. WIND DESIGN DATA:
BASIC WIND SPEED (3 SECOND GUST) 110 MPH
WIND IMPORTANCE FACTOR, I 1.25
OCCUPANCY CATEGORY I-3
WIND EXPOSURE C
INTERNAL PRESSURE COEFFICIENT +/- 5 PSF
COMPONENTS AND CLADDING PER ASCE 7-16
WIND DESIGNED UPLIFT CAPACITIES FOR ROOF:
ZONE 1: 42 PSF
ZONE 2: 56 PSF
ZONE 3: 76 PSF
WIND DESIGNED PRESSURE FOR WALL: 22 PSF
SUBGRADE PREPARATION
1. SAW CUT AND DEMOLISH THE WHOLE EXISTING CONCRETE FLOOR SLAB TO CLEAR FOR INSTALLATION OF NEW
FOOTING(S). EXCAVATE THE EXISTING SUBGRADE TO THE REQUIRED BEARING ELEVATION.
2. COMPACT THE EXPOSED SOILS TO 95% DENSITY.
3. INSTALL 15MIL VAPOR RETARDER UNDER SLAB AND FOOTINGS OVER A 4" COMPACTED SAND SUB-BASE AS SHOWN ON DETAIL #/A-X. TAPE ALL SEAMS, PENETRATIONS AND TEARS IN THE VAPOR RETARDER WITH A COMPATIBLE
WATERPROOF TAPE.
4. ADJUST ALL GRADES TO PROVIDE POSITIVE DRAINAGE AWAY FROM THE STRUCTURE. OPEN GROUND (GRASSED LAWNS AND/OR LANDSCAPED BEDS) SHALL BE SLOPED AT A MINIMUM OF A 5 PERCENT GRADE FOR AT LEAST 10 FEET
BEYOND THE PERIMETER OF THE BUILDING.
FOUNDATION NOTES
1. FOUNDATION ALLOWABLE DESIGN SOIL VALUES
CONTINUOUS FOOTING BEARING - 1.50 KSF
ISOLATED FOOTING BEARING - 2.00 KSF
2. BEARING STRATA SHOWN ON THE DETAILS IS THE EXISTING UNDISTURBED SOILS / COMPACTED FILLS AT THE
PROPOSED BEARING STRATA AT APPROXIMATE 1'-6” BELOW FINISHED FLOOR .
3. ALL FOOTING EXCAVATIONS SHALL BE CLEANED TO REMOVE ALL LOOSE SOIL MATERIAL AND OTHER DEBRIS AND
SHOULD NOT BE ALLOWED TO DESICCATE PRIOR TO PLACEMENT OF CONCRETE.
4. CONCRETE FOR FOUNDATIONS MAY BE EARTH FORMED ON THE SIDES. EARTH FORMED FOUNDATIONS SHALL BE A NEAT VERTICAL CUT, WITH NO LOOSE SPOIL OR DEBRIS IN THE BOTTOM OF THE CUT. SIGNIFICANT SLOUGHING OR
OVER EXCAVATIONS WILL REQUIRE FORMWORK.
5. NOTIFY THE TDCJ ENGINEER FOR VISUAL INSPECTION PRIOR TO PLACING CONCRETE FOUNDATION.
PATCH & REPAIR OF SLAB-ON-GRADE NOTES
1. CONCRETE PATCH / REPAIR FLOOR SLAB SHALL BE 5” MINIMUM THICK CONCRETE SLAB OVER A 15 MIL VAPOR RETARDER, OVER COMPACTED SUBGRADE. TAPE ALL SEAMS, PENETRATIONS AND TEARS IN THE VAPOR RETARDER
WITH A COMPATIBLE WATERPROOF TAPE.
2. REINFORCE SLAB WITH #3 @ 12" CTRS. EACH WAY PLACED AND SUPPORTED ON CHAIRS AT SLAB MID DEPTH.
3. PROVIDE EPOXY BONDING AGENT TO ALL CONTACT SURFACES TO NEW PATCH / REPAIR CONCRETE SLAB.
CONCRETE NOTES
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318- AS REFERENCED PER GOVERNING INTERNATIONAL
BUILDING CODE.
2. ALL CONCRETE SHALL HAVE SAND AND GRAVEL OR CRUSHED STONE AGGREGATES AND TEST 4000 PSI COMPRESSIVE STRENGTH IN 28 DAYS UNLESS NOTED OTHERWISE. NORMAL WEIGHT AGGREGATES SHALL CONFORM TO ASTM C33.
LIGHTWEIGHT AGGREGATES SHALL CONFORM TO ASTM C330.
3. CEMENT RATIO CONTENT FOR CONCRETE SHALL NOT EXCEED 0.45.
4. CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AS FOLLOWS:
REFER TO ACI 318 - SECTION 7.7 FOR CONDITIONS NOT NOTED.
GRADE BEAMS --------------------------------- 1 1/2" TOP
2" SIDES
3" BOTTOM
SLABS-ON-GRADE ----------------------------- CENTERED
5. MAXIMUM NOMINAL COARSE AGGREGATE SIZE SHALL BE 1" MAX TYPICAL UNLESS NOTED OTHERWISE.
6. CONCRETE SLUMPS SHALL BE AS FOLLOWS 5" MAX, 3" MIN
7. CONCRETE EXPOSED TO WEATHER SHALL BE AIR-ENTRAINED AS FOLLOWS:
3/4" NOMINAL AGGREGATE SIZE 4% TO 8%
1" NOMINAL AGGREGATE SIZE 3.5% TO 6.5%
8. GRADE BEAMS MAY BE FORMED WITH LINER; EXCESSIVE EXCAVATION WILL REQUIRED FORMWORK. ALL ELEMENTS OF THE FORMS, FORMWORK, BRACING AND SHORING SHALL CONSIST OF WOOD, METAL OR OTHER MANUFACTURED
PRODUCTS AS SPECIFIED.
9. THERE SHALL BE NO HORIZONTAL CONSTRUCTION JOINTS IN CONCRETE POURS. ALL CONSTRUCTION JOINTS SHALL
BE MADE IN THE CENTER OF SPANS WITH VERTICAL BULK HEADS AS IF REQUIRED.
STRUCTURAL STEEL NOTES
1. STRUCTURAL STEEL SHALL CONFORM TO A.I.S.C. "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS," ANSI/AISC
360, LATEST EDITION.
2. BOLTS AND BOLTED CONNECTIONS SHALL CONFORM TO THE REQUIREMENTS OF THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS," APPROVED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS, LATEST EDITION. CONNECTIONS SHALL BE BEARING TYPE UNLESS NOTED OTHERWISE IN DRAWINGS.
3. ALL W SHAPES SHALL CONFORM TO ASTM A992.
ALL OTHER STRUCTURAL STEEL SHAPES, PLATES, ETC., SHALL CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE.
4. GALVANIZING OF STEEL MEMBERS SHALL CONFORM TO ASTM A123/A123M. ALL STEEL FRAMING THAT COMES IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE COATED TO A G90 THICKNESS AND ALL BOLTS, HEADED STUDS
AND CONNECTORS SHALL BE COATED TO A G185 THICKNESS.
5. ALL STRUCTURAL STEEL PIPE SHALL CONFORM TO ASTM A501 OR ASTM A53, TYPES "E" OR "S”, GRADE B.
6. ALL STRUCTURAL STEEL TUBES SHALL CONFORM TO ASTM A500, GRADE B.
7. ALL STRUCTURAL STEEL DETAILS AND CONNECTIONS SHALL CONFORM TO THE STANDARDS OF THE A.I.S.C.
8. STEEL MEMBERS SHALL NOT BE SPLICED EXCEPT WHERE SHOWN ON THE DRAWINGS.
9. ALL STEEL BEAMS SHALL BE ERECTED WITH NATURAL CAMBER UP.
10. NON-COMPOSITE: THE BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL DEVELOP THE END REACTION OF THE CONNECTED BEAM. THE END REACTION OF THE CONNECTED BEAM CAN BE OBTAINED FROM THE LOAD CARRYING CAPACITY OF THE BEAM ON THE BASIS OF EQUIVALENT UNIFORM LOADS GIVEN IN PART 3 (FLEXURAL MEMBERS) OF THE 14TH EDITION A.I.S.C. MANUAL OR THE LATEST EDITION. THE MINIMUM SHEAR CAPACITY OF THE 12 KIPS SHALL BE PROVIDED FOR ALL BEAMS 8" TO 10" DEEP WITH 8 KIPS FOR BEAMS OF DEPTH LESS THAN 8".
11. WELDED CONSTRUCTION SHALL CONFORM TO THE AMERICAN WELDING SOCIETY "STRUCTURAL WELDING CODE", D1.1
ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE E70XX, UNLESS NOTED OTHERWISE.
12. ALL WELDING SHALL BE PERFORMED BY WELDERS CERTIFIED WITHIN THE LAST 6 MONTHS.
13. WHEN WELDS ARE NOT CALLED-OUT ON DRAWINGS, THEY ARE MINIMUM SIZE CONTINUOUS FILLET WELDS IN
ACCORDANCE WITH AWS D1.1.
14. TEMPORARY SUPPORTS, SUCH AS TEMPORARY GUYS, BRACES, FALSEWORK, CRIBBING OR OTHER ELEMENTS REQUIRED FOR THE ERECTION OPERATION WILL BE DETERMINED, FURNISHED, AND INSTALLED BY THE ERECTOR.
THESE TEMPORARY SUPPORTS SHALL BE CAPABLE OF SECURING THE STEEL FRAMING, OR ANY PARTLY ASSEMBLED STEEL FRAMING, AGAINST LOADS COMPARABLE IN INTENSITY TO THOSE FOR WHICH THE STRUCTURE WAS DESIGNED, RESULTING FROM WIND, SEISMIC FORCES AND ERECTION OPERATIONS.
15. THE LIFTING AND ERECTION OF PRE-ASSEMBLED ELEMENTS SUCH AS TRUSSES OR PRE-FABRICATED FRAMING ARE CONSIDERED SPECIAL ERECTION CONDITIONS. THE SELECTION OF LIFT POINTS AND ERECTION TECHNIQUES ARE THE
RESPONSIBILITY OF THE STEEL ERECTOR / CONTRACTOR.
16. THE CONTRACTOR SHALL COMPLY WITH OSHA REQUIREMENTS FOR STEEL ERECTION.
REINFORCING STEEL NOTES
1. ALL REINFORCING STEEL SHALL BE NEW DEFORMED BILLET STEEL CONFORMING TO ASTM A615, GRADE 60.
2. DETAILING OF REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE ACI DETAILING MANUAL.
4. REINFORCING BARS MAY BE SPLICED ONLY AS SHOWN ON THE DRAWINGS EXCEPT THAT REINFORCING DESIGNATED AS "CONTINUOUS" MAY BE CONTACT LAP SPLICED LENGTH OF 30 BAR DIAMETER UNLESS NOTED OTHERWISE.
5. FOR CONTINUOUS GRADE BEAM REINFORCING, 30 BAR DIAMETERS LAP SPLICES SHALL BE MADE OVER SUPPORTS FOR BOTTOM AND INTERMEDIATE BARS AND AT MIDSPAN FOR TOP BARS. AT GRADE BEAM END SUPPORTS, TOP BARS
SHALL BE HOOKED DOWN AND BOTTOM BARS SHALL BE HOOKED UP.
6. PROVIDE 2 FEET x 2 FEET CORNERS BARS OF SAME SIZE AND QUANTITY AS CONTINUOUS TOP AND BOTTOM
REINFORCING OF GRADE BEAMS AT ALL GRADE BEAM CORNERS AND INTERSECTIONS.
POST INSTALLED ANCHORS NOTES
1. POST - INSTALLED ANCHORS INCLUDE EXPANSION ANCHOR BOLTS AND BOTH ADHESIVE AND EPOXY ANCHORING SYSTEMS USING BOLTS, THREADED RODS AND REINFORCING STEEL. PROVIDE, STORE AND INSTALL PRODUCTS IN
STRICT CONFORMANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
2. EXPANSION ANCHOR BOLTS SHALL BE 1/2" DIAMETER HILTI KWIK BOLT TZ2 EXPANSION ANCHORS, ZINC PLATED WITH 4
3/4" EMBEDMENT, UNLESS NOTED OTHERWISE ON DRAWINGS.
3. POST-INSTALLED REINFORCING STEEL DOWELS SHALL BE SET WITH THE HILTI HIT HY 200-A-V3 ADHESIVE ANCHORING
SYSTEM. PROVIDE EMBEDMENT DEPTHS AS SHOWN ON DRAWINGS.
4. ADHESIVE ANCHORS SHALL BE HILTI HIT TZ OR HAS STANDARD RODS SET WITH THE HITI HIT HY 200-A-V3 ADHESIVE ANCHORING SYSTEM. REFER TO DRAWINGS FOR SIZE AND EMBEDMENT REQUIREMENTS. ALL BOLTS AND THREADED
RODS USED IN EXTERIOR EXPOSURES SHALL BE GALVANIZED.
5. PRIOR TO PLACEMENT, THE CONTRACTOR SHALL HAVE THE MANUFACTURER'S TECHNICAL REPRESENTATIVE VISIT THE SITE TO INSTRUCT THE CONSTRUCTION TEAM AND TESTING LAB ON PROPER STORAGE AND INSTALLATION TECHNIQUES. THE CONTRACTOR SHALL PROVIDE A LETTER FROM THE MANUFACTURER'S REPRESENTATIVE STATING
THAT SUCH A VISIT WAS CONDUCTED.
6. ALL EXPANSION ANCHOR BOLTS SHALL BE INSPECTED BY AN INDEPENDENT TESTING LAB FOR THE FOLLOWING:
a. CORRECT LOCATION AND POSITION OF HOLE.
b. CORRECT BOLT TYPE AND FINISH.
c. CORRECT EMBEDMENT DEPTH.
d. CONDITION OF HOLE IN CONNECTION MATERIAL (NO BURNING OF HOLES ALLOWED).
e. SNUG TIGHT FIT.
7. ADHESIVE AND EPOXY ANCHORS SHALL BE INSPECTED AND TESTED BY AN INDEPENDENT TESTING LAB AS FOLLOWS:
ALL ANCHORS SHALL BE INSPECTED FOR THE FOLLOWING:
a. CORRECT LOCATION AND POSITION OF HOLE.
b. CORRECT BOLT, THREADED ROD OR REINFORCING BAR SIZE.
c. CORRECT BOLT TYPE AND FINISH.
d. CONDITION OF HOLE IN CONNECTION MATERIAL (NO BURNING OF HOLES ALLOWED).
e. SNUG TIGHT FIT.
f. CORRECT EMBEDMENT DEPTH.
g. HOLE PREPARATION (INCLUDING DRILL BIT TYPE WHERE CRITICAL TO MANUFACTURER) AND CLEANOUT PER
MANUFACTURER'S RECOMMENDATIONS.
h. ADHESIVE TYPE, EXPIRATION DATE AND METHOD OF STORAGE.
i. ADHESIVE AND BOLT INSTALLATION.
8. THE TESTING LAB SHALL PREPARE AN INSPECTION REPORT SPECIFICALLY INDICATING DEGREE OF CONFORMANCE IN
ALL CATEGORIES LISTED ABOVE.
COLD FORMED METAL FRAMING NOTES
1. ALL STUDS AND/OR JOISTS AND ACCESSORIES SHALL BE OF THE TYPE, SIZE, GAUGE AND SPACING SHOWN ON THE DRAWINGS AND CONFORM WITH THE PROPERTIES OF LIGHT GAUGE MEMBERS AS INDICATED IN THE STEEL STUD
MANUFACTURER'S ASSOCIATION - PRODUCT TECHNICAL INFORMATION (ICBO-4943P).
2. ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" LATEST EDITION.
3. ALL FRAMING MEMBERS SHALL BE FORMED FROM CORROSION-RESISTANT STEEL (G90), CORRESPONDING TO THE REQUIREMENTS OF ASTM A653, WITH A MINIMUM YIELD STRENGTH OF 33 KSI FOR 33MIL (20 GA) AND 43 MIL (18 GA) STUDS, 50 KSI FOR 54 MIL AND HEAVIER (16 GA, 14 GA, AND 12 GA) STUDS, AND 33 KSI FOR CR-STYLE RUNNERS.
4. FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OR WELDING. SCREWS SHALL BE #10 MINIMUM AND OF SUFFICIENT SIZE TO INSURE THE STRENGTH OF THE CONNECTION. WIRE TYING OF COMPONENTS SHALL NOT
BE PERMITTED. ALL WELDS SHALL BE TOUCHED UP WITH A ZINC-RICH PAINT.
5. TEMPORARY BRACING SHALL BE PROVIDED UNTIL ERECTION IS COMPLETED.
6. SPLICES IN STUDS BETWEEN LATERALLY STRUCTURAL SUPPORTS WILL NOT BE PERMITTED.
7. PROVIDE AND INSTALL BRIDGING AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE ASSEMBLY IN CONFORMANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. AT WALLS THAT DO NOT HAVE SHEATHING ON BOTH FACES, PROVIDE QUANTITY AND TYPE OF BRIDGING TO ADEQUATELY BRIDGE ALL STUDS PER THE
MANUFACTURER'S RECOMMENDATIONS.
METAL PANEL NOTES
1. PBR TYPE PANEL, 24 GAUGE THICKNESS, 36 INCH WIDE NET COVERAGE, WITH 1-1/4 INCH HIGH MAJOR RIBS AT 12
INCHES ON CENTER WITH MINOR RIBS SPACED BETWEEN THE MAJOR RIBS.
A. MATERIAL: PRE-FINISHED GALVALUME, OR A/E APPROVED EQUAL, STEEL PER ASTM 792-86 AZ -55. FINISH SHALL BE FULL STRENGTH KYNAR 500, OR A/E APPROVED EQUAL, FLUOROPOLYMER COATING, APPLIED BY THE MANUFACTURER ON A CONTINUOUS COIL COATING LINE, WITH THE EXPOSED SIDE DRY FILM THICKNESS OF
0.70 TO 0.90 MIL OVER 0.25 TO 0.35 MIL PRIME COAT, TO PROVIDE A TOTAL DRY FILM THICKNESS OF 0.95 TO 1.25 MIL. BACK SIDE SHALL BE COATED WITH PRIMER WITH A DRY FILM THICKNESS OF 0.25 MIL. FINISH SHALL CONFORM TO ALL TESTS FOR ADHESION, FLEXIBILITY, AND LONGEVITY AS SPECIFIED BY THE KYNAR 500, OR A/E
APPROVED EQUAL, FINISH SUPPLIER; MATCH EXISTING COLOR.
B. SIDE LAPS: TWO FULLY OVERLAPPING MAJOR RIBS SECURED TOGETHER WITH NO. 12- 14 SELF-DRILLING
TAPPING FASTENERS WITH NEOPRENE WASHERS, COLOR-MATCHED CARBON STEEL FASTENERS.
C. PROVIDE 1" WIDE BUTYL TAPE @ SIDE LAPS OF MAJOR RIBS OF ALL ROOF PANELS.
2. METAL PANEL SHALL BE PRE-CUT IN FULL LENGTH; MEETING UL CLASSIFIED 90 RATED ASSEMBLES.
AIR INFILTRATION: MAXIMUM 0.011 CFM/LF OF SEAM AT STATIC PRESSURE OF +/-6.24 PSF WHEN TESTED PER ASTM E1680.
WATER PENETRATION: NO UNCONTROLLED WATER PENETRATION THROUGH PANEL JOINTS AT A STATIC PRESSURE
OF 12.0 PSF WHEN TESTED IN ACCORDANCE TO ASTM E1646.
3 FLASHING AND TRIM SHALL MATCH MATERIAL, THICKNESS, FINISH, AND COLOR OF METAL PANEL, FURNISH AS REQUIRED AND PER SPECIFIED TO PROVIDE WEATHER TIGHTNESS AND A FINISHED APPEARANCE.
4. SEALANT, MASTIC AND CLOSURES SHALL BE PER MANUFACTURER'S STANDARDS. ENSURE ALL COMPONENTS AND
MATERIALS ARE FROM A SINGLE MANUFACTURER.
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text J
T
X
X X
X
X X
X X
X X
X X
X
XX
X X
X
W W
W W
W
W
W
W
W
W
W
W
W
W W W W W W W W W W W W W W W W W
W
XXXXXXXXXXXXX
X X
X X
X X
G
AS
G
AS
G
AS
G
AS
G
AS
XX
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
A
N O
D
AT
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
PR
O
JE
C
T N
AM
E:
D
ES
C R
IP
TI
O N
R
EV
IS
IO
N
1 2 3 4 5 1 2
TEXAS DEPARTMENT
OF
CRIMINAL JUSTICE
ENGINEERING SERVICE
PO BOX 4011
TWO FINANCIAL PLAZA,
SUITE 400
HUNTSVILLE, TX 77340
TITLE:
M W
R
U N
IT
EN
G
IN
EE
R
D R
AW
N
B Y:
SC
AL
E:
A
S
SH
O W
N D
AT
E
SHEET OF
IN
ST
AL
L
W
AT
ER
S
O
FT
EN
ER
S
- U
N
IT
W
ID
E
TI
M
K
IE
R
SZ
, P E
SA
N
S
AB
A
B .G
O U
BE
R
T
SITE PLAN
A-1 03 09
/1
8/
IS
SU
ED
F O
R
FI
R
ST
T
EC
H N
IC
AL
R
EV
N
ST
R U C
TI
O N
/2
9/
PL
O
T D
AT
E:
7/
/2
1:
P
M D
R
AW
IN
G
P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G \a ca d lib ra ry \p ro je ct d ra w in g da ta ba se
\s an s ab a (0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C H
S
TR
U
C T.
dw g
BRAND OR MANUFACTURER'S REFERENCES ARE DESCRIPTIVE ONLY, AND INDICATE
TYPE AND QUALITY TO BE PROVIDED. ALL REFERENCES TO BRAND OR
MANUFACTURER NAMES SHALL BE INTERPRETED TO INCLUDE THE LANGUAGE "OR
A/E APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING SPECIFICATIONS
WILL BE CONSIDERED, IRRESPECTIVE OF THE LANGUAGE "OR A/E APPROVED EQUAL"
APPEARING IN CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.
SITE PLAN
Scale: 1/8" = 1'-0"1
N
PROPOSED 10'-6" x 25'-2"
METAL BUILDING
PROPOSED 5"
CONCRETE SLAB
EXISTING CONCRETE
SIDEWALK
EXISTING CONCRETE SWALE
RUNNING UNDER SIDEWALK
PROPOSED SWALE/DITCH
RUNNING TO EXISTING SWALE
EXISTING GAS LINE TO REMAIN IN PLACE,
DEPTH TO BE VERIFIED BEFORE DIGGING,
RELOCATE IF NECESSARY
8" PVC PIPE
W
X
SAN SABA UNIT
MAIN BUILDING
SECTOR 4
PARKING LOT
GAS
REGRADE THIS AREA FOR
STORMWATER TO DRAIN
INTO SWALE
REGRADE THIS AREA FOR STORMWATER
TO DRAIN INTO SWALE
LEGEND:
STORMWATER SHEET FLOW
EXISTING WATER LINE
EXISTING CHAIN-LINK FENCE
EXISTING GAS LINE
DITCH / SWALE FLOWLINE DIRECTION
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text J
HEATER
A
N O
D
AT
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
PR
O
JE
C
T N
AM
E:
D
ES
C R
IP
TI
O N
R
EV
IS
IO
N
1 2 3 4 5 1 2
TEXAS DEPARTMENT
OF
CRIMINAL JUSTICE
ENGINEERING SERVICE
PO BOX 4011
TWO FINANCIAL PLAZA,
SUITE 400
HUNTSVILLE, TX 77340
TITLE:
M W
R
U N
IT
EN
G
IN
EE
R
D R
AW
N
B Y:
SC
AL
E:
A
S
SH
O W
N D
AT
E
SHEET OF
IN
ST
AL
L
W
AT
ER
S
O
FT
EN
ER
S
- U
N
IT
W
ID
E
TI
M
K
IE
R
SZ
, P E
SA
N
S
AB
A
B .G
O U
BE
R
T
FLOOR PLANS
A-2 04 09
/1
8/
IS
SU
ED
F O
R
FI
R
ST
T
EC
H N
IC
AL
R
EV
N sT R
U C
TI
O
N
/2 9/
PL
O
T D
AT
E:
7/
/2
1:
P
M D
R
AW
IN
G
P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G \a ca d lib ra ry \p ro je ct d ra w in g da ta ba se
\s an s ab a (0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C H
S
TR
U
C T.
dw g
BRAND OR MANUFACTURER'S REFERENCES ARE DESCRIPTIVE ONLY, AND INDICATE
TYPE AND QUALITY TO BE PROVIDED. ALL REFERENCES TO BRAND OR
MANUFACTURER NAMES SHALL BE INTERPRETED TO INCLUDE THE LANGUAGE "OR
A/E APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING SPECIFICATIONS
WILL BE CONSIDERED, IRRESPECTIVE OF THE LANGUAGE "OR A/E APPROVED EQUAL"
APPEARING IN CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.
A-4
6" CEE STUD WALL
W/ 24 GA. PBR PANEL
5/8" HARD
CEMENT BOARD
'-6
O
U T
TO
O
U T
W
AL
L
FR
AM
IN
G
FLOOR PLAN
Scale: 1/4" = 1'-0"2
N
NOTES:
1. WIND CROSS BRACING SHALL BE MOVED
TO THE NEXT BAY.
2. SLOPE CONCRETE SLAB INSIDE
BUILDING TOWARDS FLOOR DRAINS
AS SHOWN ON 1/A-2.
INSTALL NEW 6'x7'
OVERHEAD ROLL-UP DOOR
5" CONCRETE SLAB
25'-2" OUT TO OUT WALL FRAMING
'-3
/4 " F
.V
FOUNDATION PLAN
Scale: 1/4" = 1'-0"1
N
CREATE OPENING FOR NEW
6'x7' OVERHEAD DOOR
6'-7 1/4"10'-9 7/8" F.V.
2'-7 3/8" F.V.
7'-0 3/4"
25'-2 3/4"
'-6
6' -0
10'-2 3/4" F.V.
4'-10 3/4" F.V.
INSTALL NEW 6'x10'
H.M. DOOR,
REF. SCHEDULE ON A-3
DORMITORY AREA
8" HIGH
CONCRETE CURB
#3 DOWELS @ 12" O.C. IN
EXISTING SLAB, TYPICAL
4" Ø FLOOR DRAIN
PROVIDE #4 REBARS @
12 O.C.E.W FOR ACCESS
WAY TO BUILDING SLAB
EXISTING SIDEWALK
ROOF PLAN
Scale: 1/4" = 1'-0"4
N
EXISTING COVERED SIDEWALK
ROOF FRAMING PLAN
Scale: 1/4" = 1'-0"3
N
14'-1 1/2" F.V.
5'-11" F.V.
8 x 2 CEE RAFTERS @ 24" O.C. = 25'-2"
3' -1
3/
4"
WALL STRUCTURE
EXISTING SIDEWALK
8'-5" 8'-4" 8'-5"
PROPOSED
SIDEWALK
1'-5 1/2" F.V.
3'-8" F.V.
'-7
/4
3' -1
3/
4" 3'
-1
1/ 4"
(2) 3 x 6 BENT PLATES 18 GA.
8 x 2 CEE 18 GA.
8 x 2 CEE 18 GA.
x
C
EE
G
A.
T
YP
CL
CL
CL
CLCL
CL CL
EXISTING SIDEWALK
DORMITORY AREADORMITORY AREA
DORMITORY AREA
6'-1 1/4"
DOOR
PROPOSED
SIDEWALK
6" Ø ROOF VENT,
SEE DETAILS 4&5/A-7EXISTING WALL
SLOPE 14" / 12" MIN.
WALL FLASHING,
SEE DETAIL 2/A-5
STAINLESS STEEL GUTTER,
SEE DETAIL 1/A-5
RAKE TRIM (TYP),
SEE DETAIL 5/A-6
APPROX. LOCATION OF
3"x4" DOWNSPOUT
1' -3
" O
VE
R H
AN
G
LEGEND:
DUPLEX RECEPTACLE WITH METAL COVER PLATE
LIGHT SWITCH WITH METAL COVER PLATE
LED LIGHT FIXTURE - MODEL
99FL-C-NA-7-2-120 BY KENAL MFG
WALL PACK 32W LED, 120V BY PRUF
4" DIA. FLOOR DRAIN
RESIN RESIN RESIN RESIN
BRINE
TANK
WATER SOFTENER SYSTEM
ON 64" x 104" SKID
GENERAL NOTE:
MATCH EXISTING ADJACENT COLORS &
SUBMIT TO A/E FOR FINAL APPROVAL.
ALL METAL SHALL BE PRE - FINISHED
FROM FACTORY WITH A STANARD FINISH.
INSTALL WALL PACK
ABOVE DOOR
NOTE: ALL WIRING SHALL BE IN 3/4" DIA. CONDUIT.
10'-3 1/2" F.V.
HEATER
OUTLET
A-4
A-4
A-4 12" x 30" CONT.
GRADE BEAM
1' -0
3/4" EXP. JOINT
8 x 2 EAVE STRUT 18 GA.
A-5
DOUBLE 6" STUDS
@ DOOR JAMB
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text J
N O
D
AT
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
PR
O
JE
C
T N
AM
E:
D
ES
C R
IP
TI
O N
R
EV
IS
IO
N
1 2 3 4 5 1 2
TEXAS DEPARTMENT
OF
CRIMINAL JUSTICE
ENGINEERING SERVICE
PO BOX 4011
TWO FINANCIAL PLAZA,
SUITE 400
HUNTSVILLE, TX 77340
TITLE:
M W
R
U N
IT
EN
G
IN
EE
R
D R
AW
N
B Y:
SC
AL
E:
A
S
SH
O W
N D
AT
E
SHEET OF
IN
ST
AL
L
W
AT
ER
S
O
FT
EN
ER
S
- U
N
IT
W
ID
E
TI
M
K
IE
R
SZ
, P E
SA
N
S
AB
A
B .G
O U
BE
R
T
ELEVATIONS
A-3 05 09
/1
8/
IS
SU
ED
F O
R
FI
R
ST
T
EC
H N
IC
AL
R
EV
N
ST
R U C
TI
O N
/2
9/
PL
O
T D
AT
E:
7/
/2
1:
P
M D
R
AW
IN
G
P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G \a ca d lib ra ry \p ro je ct d ra w in g da ta ba se
\s an s ab a (0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C H
S
TR
U
C T.
dw g
BRAND OR MANUFACTURER'S REFERENCES ARE DESCRIPTIVE ONLY, AND INDICATE
TYPE AND QUALITY TO BE PROVIDED. ALL REFERENCES TO BRAND OR
MANUFACTURER NAMES SHALL BE INTERPRETED TO INCLUDE THE LANGUAGE "OR
A/E APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING SPECIFICATIONS
WILL BE CONSIDERED, IRRESPECTIVE OF THE LANGUAGE "OR A/E APPROVED EQUAL"
APPEARING IN CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.
SOUTH ELEVATION
Scale: 1" = 3/8"1
EAST ELEVATION
Scale: 1" = 3/8"2WEST ELEVATION
Scale: 1" = 3/8"3
AS
S
C H
ED
∠C
SS
1 2"
2" THK PAINTED
BLUE H.M.
D1
F1
2" 2"AS
SCHED.
14 GA. PAINTED
BLUE H.M.
2"
FRAME TYPES
DOOR SCHEDULE
MARK WIDTH HEIGHT DOOR TYPE FRAME TYPE
1 6'-0" 7'-0" D1 F1
HARDWARE SET
DOOR ITEM
2" PR BUTT HINGES
1 LOCKSET
1 WEATHER STRIP 369 XAP - PEMKO OR A/E APPROVED EQ.
1 SWEEP
1 STOP
2 CLOSERS W/ STOP @ 135 & HOLD OPEN FEATURE, NORTON OR A/E APPROVED EQUAL.
SIZE
2" x 51 2" x BB x NRP
1060 - 1 SOUTHERN STEEL OR A/E APPROVED EQ.
MANUFACTURER
McKINNEY OR A/E APPROVED EQ.
NOTES:
1. ELEV. 100'-0" IS ASSUMED. MAINTAIN
POSITIVE SLOPE AWAY FROM NEW
BLDG. TOWARDS EXISTING SIDEWALK.
PROVIDE 2% MAX. SLOPE - IN ANY
DIRECTION.
2. ALL DIMENSIONS TO FACE OF STUD
UNLESS NOTED OTHERWISE.
3. REFER COLD FORMED METAL FRAMING
NOTES AND ROOF METAL PANEL NOTES
ON SHEET A-0.
NOTES
UNDERCUT DOOR 1"
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text J
N O
D
AT
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
PR
O
JE
C
T N
AM
E:
D
ES
C R
IP
TI
O N
R
EV
IS
IO
N
1 2 3 4 5 1 2
TEXAS DEPARTMENT
OF
CRIMINAL JUSTICE
ENGINEERING SERVICE
PO BOX 4011
TWO FINANCIAL PLAZA,
SUITE 400
HUNTSVILLE, TX 77340
TITLE:
M W
R
U N
IT
EN
G
IN
EE
R
D R
AW
N
B Y:
SC
AL
E:
A
S
SH
O W
N D
AT
E
SHEET OF
IN
ST
AL
L
W
AT
ER
S
O
FT
EN
ER
S
- U
N
IT
W
ID
E
TI
M
K
IE
R
SZ
, P E
SA
N
S
AB
A
B .G
O U
BE
R
T
SECTIONS
A-4 06 09
/1
8/
IS
SU
ED
F O
R
FI
R
ST
T
EC
H N
IC
AL
R
EV
N
ST
R U C
TI
O N
/2
9/
PL
O
T D
AT
E:
7/
/2
1:
P
M D
R
AW
IN
G
P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G \a ca d lib ra ry \p ro je ct d ra w in g da ta ba se
\s an s ab a (0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C H
S
TR
U
C T.
dw g
BRAND OR MANUFACTURER'S REFERENCES ARE DESCRIPTIVE ONLY, AND INDICATE
TYPE AND QUALITY TO BE PROVIDED. ALL REFERENCES TO BRAND OR
MANUFACTURER NAMES SHALL BE INTERPRETED TO INCLUDE THE LANGUAGE "OR
A/E APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING SPECIFICATIONS
WILL BE CONSIDERED, IRRESPECTIVE OF THE LANGUAGE "OR A/E APPROVED EQUAL"
APPEARING IN CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.
STAINLESS STEEL GUTTER
7'
-0
BUILDING SECTION
Scale: 3/4" = 1'-0"1
A-5
A-5
A-5
SECTION @ EXTERIOR DOOR
Scale: 3/4" = 1'-0"3
SECTION @ INTERIOR DOOR
Scale: 3/4" = 1'-0"4
6' x 10'
H.M. DOUBLE
DOOR
EL. 100'-0"
T.O. SLAB / EXIST. FLOOR
EL. 112'-0"
BEARING
A-5
FOUNDATION DETAIL
Scale: 3/4" = 1'-0"2
'-0
5" THICK CONC. SLAB
W/ #3 @ 12" O.C.E.W., #3 DOWELS INTO EXIST. SLAB,
REF. 1/A-2
PBR PANEL, 24GA.
DOOR HEAD TRIM
6" CEE STUD WALL, 18GA.
W/ R-13 WALL INSULATION BATT
W/ PAPER FACED BACKING
6"x6" CFM BOXED BEAM
RAKE TRIM
PBR PANEL, 24GA.
8" CEE PURLIN,
REF. ROOF FRAMING PLAN
ROOF INSULATION, R-30
W/ PAPER FACED BACKING
6' (W) x 10' (H) H. M.
DOUBLE DOOR,
DOOR FRAME
SHOULD WRAP STUDS
AND CEMENT BOARD
5" THICK CONC. SLAB,
REF. 2/A-4 FOR
SLAB REINFORCEMENT
NEW CEE 10"x3" CHANNEL
6"x6" CFM BOXED BEAM
EXIST. WALL STRUCTURE,
ADD 10" CEE STUD WALL ABOVE
OPENING FOR NEW DOOR
6" CEE TRACK
5/8" CEMENT BOARD
EXIST. FOUNDATION
5" THICK CONC. SLAB,
REF. 2/A-4
FOR SLAB REINFORCMENT
EXIST. WALL INSULATION
TO REMAIN IN PLACE
6' (W) x 7' (H) OVERHEAD
ROLL-UP DOOR
BLOCKING @ 4' MAX. VERTICALLY,
TYPICAL FOR ALL EXT. WALLS
18GA., 6" CEE STUD STRUCTURE
@ 24" O.C. MAX.
EL. 100'-8"
T.O. CURB
PBR PANEL, 24GA.
6" CEE STEEL STUD 18GA.
@ 24" O.C. MAX.,
W/ R-13 WALL INSULATION BATT
W/ PAPER FACED BACKING
5" THICK CONC. FOUNDATION,
REF. 2/A-4 FOR SLAB REINFORCEMENT
6" WIDE CONC. CURB BEYOND
WALL BASE TRIM, REF. 1/A-6
STEEL WALL STRUCTURE BEYOND
BLOCKING @ 4' MAX. VERTICALLY,
TYPICAL FOR ALL EXT. WALLS
PBR PANEL, 24GA.
ROOF INSULATION, R-30
W/ PAPER FACED BACKING
ABOVE 5/8" FIRE RATED GREEN BOARD
8" CEE ROOF STRUCTURE,
REF. ROOF FRAMING PLAN 3/A-2
ROOF FLASHING @ EXISTING WALL,
REF. DETAIL 2/A-5
DOUBLE 6" STUDS @ DOOR JAMB
5/8" CEMENT BOARD
ALL AROUND ON INTERIOR SIDE
EX
IS
TI
N
G W
AL
L
8" HIGH CONC. CURB W/
CONT. #3 @ TOP & BOT. OF CURB,
AND 2'-0" DOWEL @ 12" O.C.
6"
TYP.
EXISTING
FOUNDATION / SLAB
#3 x 2'-0" DOWELS @ 12" O.C.
EMBEDDED 4" MIN.
INTO EXIST. CONC. SLAB
NEW MECH. BLDG. SLAB / FOUNDATION
F'c = 3500 PSI MIN.
5" THICK CONC. SLAB
W/ #3 @ 12" O.C.E.W. @ SLAB CENTER
4" COMPACTED SAND
PROVIDE 15 ML VAPOR BARRIER
AGAINST INTERIOR FACE
OF NEW SLAB & GRADE BEAMEL. 97'-6"
BOT. OF GRADE BEAM
EL. 100'-0"
T.O. SLAB
(2) - #5 @ TOP & BOT. & MID HEIGHT
W/ #3 STIRRUPS @ 12" O.C.
12"
TYP.
RELOCATE EXIST. 10" WALL GIRT TO
SUPPORT TOP OF DOOR HEAD BOX
3/4" EXPANSION JOINT IN
COMPRESSIBLE MATERIAL
5/8" FIRE RATED GREEN BOARD
6" COLD FORMED METAL BOXED BEAM
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text J
N O
D
AT
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
PR
O
JE
C
T N
AM
E:
D
ES
C R
IP
TI
O N
R
EV
IS
IO
N
1 2 3 4 5 1 2
TEXAS DEPARTMENT
OF
CRIMINAL JUSTICE
ENGINEERING SERVICE
PO BOX 4011
TWO FINANCIAL PLAZA,
SUITE 400
HUNTSVILLE, TX 77340
TITLE:
M W
R
U N
IT
EN
G
IN
EE
R
D R
AW
N
B Y:
SC
AL
E:
A
S
SH
O W
N D
AT
E
SHEET OF
IN
ST
AL
L
W
AT
ER
S
O
FT
EN
ER
S
- U
N
IT
W
ID
E
TI
M
K
IE
R
SZ
, P E
SA
N
S
AB
A
B .G
O U
BE
R
T
DETAILS
A-5 07 09
/1
8/
IS
SU
ED
F O
R
FI
R
ST
T
EC
H N
IC
AL
R
EV
N
ST
R U C
TI
O N
/2
9/
PL
O
T D
AT
E:
7/
/2
1:
P
M D
R
AW
IN
G
P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G \a ca d lib ra ry \p ro je ct d ra w in g da ta ba se
\s an s ab a (0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C H
S
TR
U
C T.
dw g
BRAND OR MANUFACTURER'S REFERENCES ARE DESCRIPTIVE ONLY, AND INDICATE
TYPE AND QUALITY TO BE PROVIDED. ALL REFERENCES TO BRAND OR
MANUFACTURER NAMES SHALL BE INTERPRETED TO INCLUDE THE LANGUAGE "OR
A/E APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING SPECIFICATIONS
WILL BE CONSIDERED, IRRESPECTIVE OF THE LANGUAGE "OR A/E APPROVED EQUAL"
APPEARING IN CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.
NEOPRENE CLOSURE
WATER STOP
ROOF EAVE DETAIL
Scale: 3" = 1'-0"1
METAL FASCIA
5/8" METAL FLAT
SOFFIT
ROOF PANEL, 24GA.
R PANEL SIDING, 24GA.
CLIP ANGLE
8" METAL RAFTER,
REF. PLAN
CONT. ROOF R-30 INSULATION
W/ PAPER FACED BACKING
ABOVE 5/8" FIRE RATED GREEN BOARD
6" METAL CEE STUD, 18GA.
@ 24" O.C. MAX. (TYP)
WALL INSULATION R-13 BATT
W/ PAPER FACED BACKING
FLASHING DETAIL. @ EXIST. BLDG.
Scale: 3" = 1'-0"2
NEOPRENE CLOSURE
WATER STOP
ROOF PANEL, 24GA.
CONT. ROOF FLASHING
COUNTER FLASHING
FASTENERS, TYP.
6" CEE TRACK FOR
CLIP ANGLE SUPPORT
6" METAL STUD STRUCTURE
5/8" CEMENT BOARD
EXISTING WALL PANEL
SEALANT
6" BLOCKING @ 4'-0" MAX.
EXISTING INSULATION BATT
W/ POULTRY NETTING
TO REMAIN IN PLACE
5/8" CEMENT BOARD
TYP. CLIP ATTACHMENT
Scale: 3" = 1'-0"5
PLAN
ELEV.
ROOF PANEL, 24GA.
DOOR HEAD DETAIL
Scale: 3" = 1'-0"4
RAKE TRIM DETAIL
Scale: 3" = 1'-0"3
SDS3" x 3" ANGLE
16GA.
3/4" TYP.
3"
3"
RAKE TRIM
8" CEE PURLIN, REF. 1/A-5
8" CEE CHANNEL,
REF. ROOF FRAMING PLAN
CONT. ROOF R-30 INSULATION BATT
W/ PAPER FACED BACKING ABOVE 5/8"
FIRE RATED GREEN BOARD CEILING
5/8" CEMENT BOARD
WALL INSULATION R-13 BATT
W/ PAPER FACED BACKING
R PANEL SIDING, 24GA.
6" METAL CEE STUD, 18GA.
@ 24" O.C. MAX. (TYP)
6" CEE TRACK
6" METAL CEE STUD, 18GA.
@ 24" O.C. MAX. (TYP)
6" CFM BOXED BEAM
5/8" CEMENT BOARD
6" CEE TRACK
WALL PANEL CLOSURE
CEE 10"x3" CHANNEL 12 GA.
BOLTED CONNECTED TO
VERT. CEE'S @ DOOR JAMB
RELOCATE EXIST.
WALL GIRT TO FIT
BETWEEN NEW CEE'S
@ DOOR JAMB
10" CEE WALL STUD
DOOR HEADBOX
EXIST. WALL
INSULATION BATT
5/8" CEMENT BOARD
CLIP ANGLE
3" X 6" BENT PLATES,
ADJUST HEIGHT AS REQUIRED
TRIPLE 6" STUDS
FOR OPENING IN NEW
WALL STRUCTURE
NEW CEE 10"x3" CHANNEL, 12 GA.
OVERHEAD DOOR JAMB DETAIL
Scale: 3" = 1'-0"6
6"x7' ROLL-UP DOOR
LLV8x4x1/4" ANGLE x 4" LONG
W/ (2) 1/2" Ø ANCHOR BOLTS
WALL GIRT WITH INSULATION
6" BLOCKING @ 4'-0" MAX.
3" 4'
3"
4'
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text J
N O
D
AT
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
PR
O
JE
C
T N
AM
E:
D
ES
C R
IP
TI
O N
R
EV
IS
IO
N
1 2 3 4 5 1 2
TEXAS DEPARTMENT
OF
CRIMINAL JUSTICE
ENGINEERING SERVICE
PO BOX 4011
TWO FINANCIAL PLAZA,
SUITE 400
HUNTSVILLE, TX 77340
TITLE:
M W
R
U N
IT
EN
G
IN
EE
R
D R
AW
N
B Y:
SC
AL
E:
A
S
SH
O W
N D
AT
E
SHEET OF
IN
ST
AL
L
W
AT
ER
S
O
FT
EN
ER
S
- U
N
IT
W
ID
E
TI
M
K
IE
R
SZ
, P E
SA
N
S
AB
A
B .G
O U
BE
R
T
STANDARD
DETAILS
A-6 08 09
/1
8/
IS
SU
ED
F O
R
FI
R
ST
T
EC
H N
IC
AL
R
EV
N
ST
R U C
TI
O N
/2
9/
PL
O
T D
AT
E:
7/
/2
1:
P
M D
R
AW
IN
G
P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G \a ca d lib ra ry \p ro je ct d ra w in g da ta ba se
\s an s ab a (0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C H
S
TR
U
C T.
dw g
BRAND OR MANUFACTURER'S REFERENCES ARE DESCRIPTIVE ONLY, AND INDICATE
TYPE AND QUALITY TO BE PROVIDED. ALL REFERENCES TO BRAND OR
MANUFACTURER NAMES SHALL BE INTERPRETED TO INCLUDE THE LANGUAGE "OR
A/E APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING SPECIFICATIONS
WILL BE CONSIDERED, IRRESPECTIVE OF THE LANGUAGE "OR A/E APPROVED EQUAL"
APPEARING IN CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.
WALL BASE DETAIL
Scale: 3" = 1'-0"1
NEW WALL TO EXISTING FLASHING DETAIL
Scale: 3" = 1'-0"2
WALL CORNER TRIM DETAIL
Scale: 3" = 1'-0"3
RAKE TRIM DETAIL
Scale: 3" = 1'-0"5
EAVE SEALANT DETAIL
Scale: 3" = 1'-0"4FASTENING SCHEDULE
Scale: 3" = 1'-0"6
NOTE: REFER TO 4/A-7 FOR WIND UPLIFT ZONES
AutoCAD SHX Text
FIN. FLOOR
AutoCAD SHX Text
BASE TRIM
AutoCAD SHX Text
PBR WALL PANEL
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
CEE TRACK (18 GA. MIN.)
AutoCAD SHX Text
O/O DIMENSION
AutoCAD SHX Text
(SEE PLAN)
AutoCAD SHX Text 1/4"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
(SEE FASTENER SPACING DETAIL)
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER (6) PER PANEL
AutoCAD SHX Text
(PRE-DRILL ANGLE)
AutoCAD SHX Text 1/4 x 1 1/4 MASONRY
AutoCAD SHX Text
ANCHOR @ 36" O.C.
AutoCAD SHX Text
(SEE PLAN)
AutoCAD SHX Text
O/O DIMENSION
AutoCAD SHX Text
EXISTING WALL PANEL
AutoCAD SHX Text
O/O DIMENSION
AutoCAD SHX Text
(SEE PLAN)
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER @ EA. SUPPORT
AutoCAD SHX Text
INSIDE CORNER TRIM
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text
EXISTING ZEE GIRT
AutoCAD SHX Text
6" CEE WALL GIRT 18GA.
AutoCAD SHX Text
(SEE FASTENER SPACING DETAIL)
AutoCAD SHX Text 1/4-14 x 7/8 LONG-LIFE LAPTEK
AutoCAD SHX Text
W/WASHER
AutoCAD SHX Text
@ EA. SUPPORT
AutoCAD SHX Text
(SEE PLAN)
AutoCAD SHX Text
O/O DIMENSION
AutoCAD SHX Text
OUTSIDE CORNER TRIM
AutoCAD SHX Text 1/4-14 x 7/8 LONG-LIFE LAPTEK
AutoCAD SHX Text
W/WASHER
AutoCAD SHX Text
(SEE PLAN)
AutoCAD SHX Text
O/O DIMENSION
AutoCAD SHX Text
PBR WALL PANEL
AutoCAD SHX Text
16 GA. SHEETING ANGLE
AutoCAD SHX Text
CEE GIRT
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text
(SEE FASTENER SPACING DETAIL)
AutoCAD SHX Text 1/4-14 x 7/8 LONG-LIFE LAPTEK
AutoCAD SHX Text
W/WASHER @ 12" O.C.
AutoCAD SHX Text
OUTSIDE CLOSURE
AutoCAD SHX Text
WALL PANEL
AutoCAD SHX Text 2 x 4 x 16 GA. ANGLE
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text
(SEE FASTENER SPACING DETAIL)
AutoCAD SHX Text 1/4-14 x 7/8 LONG-LIFE LAPTEK
AutoCAD SHX Text
W/WASHER
AutoCAD SHX Text 1" x 3/32" TAPE SEALER
AutoCAD SHX Text
PBR ROOF PANEL
AutoCAD SHX Text
CEE PURLIN
AutoCAD SHX Text
O/O DIMENSION
AutoCAD SHX Text
(SEE PLAN)
AutoCAD SHX Text
SCULPTURED RAKE TRIM
AutoCAD SHX Text
%%UFINISHING OFF MODULE
AutoCAD SHX Text
FIELD CUT PANEL AS REQ'D.
AutoCAD SHX Text
& BEND UP 1" LEG
AutoCAD SHX Text 1/4-14 x 7/8 LONG-LIFE LAPTEK
AutoCAD SHX Text
W/WASHER
AutoCAD SHX Text 1" x 3/32" TAPE SEALER
AutoCAD SHX Text
PBR ROOF PANEL
AutoCAD SHX Text
SCULPTURED RAKE TRIM
AutoCAD SHX Text 12-14 x 1 1/4 SELF-DRILLER
AutoCAD SHX Text
W/WASHER
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text
EAVE STRUT
AutoCAD SHX Text
EAVE STRUT
AutoCAD SHX Text
PBR ROOF PANEL
AutoCAD SHX Text
EAVE TRIM
AutoCAD SHX Text
WALL PANEL
AutoCAD SHX Text
OUTSIDE CLOSURE
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text
O/O DIMENSION
AutoCAD SHX Text
(SEE PLAN)
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
REFERENCE TYPICAL TRIM
AutoCAD SHX Text
LAP SECTIONS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WALL PANEL
AutoCAD SHX Text 1 3/4"
AutoCAD SHX Text
THICKNESS
AutoCAD SHX Text
OVERHANG
AutoCAD SHX Text
INSIDE CLOSURE
AutoCAD SHX Text 1" x 3/32" TAPE SEALER
AutoCAD SHX Text
TOP & BOTTOM OF CLOSURE
AutoCAD SHX Text
PBR ROOF PANEL
AutoCAD SHX Text
INSIDE CLOSURE
AutoCAD SHX Text
EAVE TRIM
AutoCAD SHX Text 1" x 3/32" TAPE SEALER
AutoCAD SHX Text
TOP & BOTTOM OF CLOSURE
AutoCAD SHX Text 1" x 3/32" TAPE SEALER
AutoCAD SHX Text
SEAL TO TAPE SEALER @
AutoCAD SHX Text
EAVE & SIDELAP
AutoCAD SHX Text 1/2" x 3/32" TAPE SEALER
AutoCAD SHX Text
@ PANEL SIDELAP
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text
(6) PER PANEL
AutoCAD SHX Text 1/4-14 x 7/8 LONG-LIFE LAPTEK
AutoCAD SHX Text
W/WASHER
AutoCAD SHX Text 1/8 x 3/8 POP RIVET
AutoCAD SHX Text
%%UPBR FASTENER SPACING @ ROOF INTERIOR ZONE ( 1 )
AutoCAD SHX Text
%%UPBR FASTENER SPACING @ PERIMETER AND CORNER ZONES ( 2 & 3 )
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text 9 1/2"
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text J
N O
D
AT
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
PR
O
JE
C
T N
AM
E:
D
ES
C R
IP
TI
O N
R
EV
IS
IO
N
1 2 3 4 5 1 2
TEXAS DEPARTMENT
OF
CRIMINAL JUSTICE
ENGINEERING SERVICE
PO BOX 4011
TWO FINANCIAL PLAZA,
SUITE 400
HUNTSVILLE, TX 77340
TITLE:
M W
R
U N
IT
EN
G
IN
EE
R
D R
AW
N
B Y:
SC
AL
E:
A
S
SH
O W
N D
AT
E
SHEET OF
IN
ST
AL
L
W
AT
ER
S
O
FT
EN
ER
S
- U
N
IT
W
ID
E
TI
M
K
IE
R
SZ
, P E
SA
N
S
AB
A
B .G
O U
BE
R
T
STANDARD
DETAILS
A-7 09 09
/1
8/
IS
SU
ED
F O
R
FI
R
ST
T
EC
H N
IC
AL
R
EV
N
ST
R U C
TI
O N
/2
9/
PL
O
T D
AT
E:
7/
/2
1:
P
M D
R
AW
IN
G
P
AT
H
J:
\D
EP
TI
N
FO
\e ng in ee rin g\ en gi ne er in g gr ou p\
EN
G \a ca d lib ra ry \p ro je ct d ra w in g da ta ba se
\s an s ab a (0
)\0
- i ns ta ll w at er s of te ne rs un it w id e\
AR
C H
S
TR
U
C T.
dw g
BRAND OR MANUFACTURER'S REFERENCES ARE DESCRIPTIVE ONLY, AND INDICATE
TYPE AND QUALITY TO BE PROVIDED. ALL REFERENCES TO BRAND OR
MANUFACTURER NAMES SHALL BE INTERPRETED TO INCLUDE THE LANGUAGE "OR
A/E APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING SPECIFICATIONS
WILL BE CONSIDERED, IRRESPECTIVE OF THE LANGUAGE "OR A/E APPROVED EQUAL"
APPEARING IN CONJUNCTION WITH THE BRAND OR MANUFACTURER NAME.
ROOF DETAILS
Scale: N.T.S.1
3'-0"
1-4"
2" 2"
3"
3" 10"
3"
2" 6"
2" 1'-9"
(5000 PSI) CONCRETE
REINFORCED WITH 6x6-W2.9xW2.9
WWM - APPROX. 155 LBS
SPLASH BLOCK DETAIL
Scale: N.T.S.2
ROOF WIND UPLIFT DIAGRAM
Scale: 3/8" = 1'-0"3
WIND UPLIFT ZONES:
ZONE 1 : 42 PSF (INTERIOR)
ZONE 2 : 56 PSF (PERIMETER)
ZONE 3 : 76 PSF (CORNER)
WATERTIGHT SHEET
METAL RAIN COLLAR
WITH STAINLESS
STEEL DRAWBAND.
OVERLAP FLASHING
COLLAR 3" MIN.
NOTES:
1. VENT STACKS SHALL NOT PENETRATE
OVERLAPPING STANDING SEAMS.
2. REROUTE STACK BELOW DECKING AS
REQUIRED TO PENETRATE THE CENTER OF
ROOF PANEL.
WATER CUT-OFF MASTIC
22 GA. PREFINISHED SHEET
METAL RAIN COLLAR
STAINLESS STEEL CLAMP RING
SEALANT
NOTE:
CONTRACTOR TO RELOCATE PENETRATIONS AS REQUIRED
SO NEW RUBBER BOOT IS LOCATED EQUIDISTANT BETWEEN
OVERLAPPING RIBS AND DOES NOT EXTEND OVER THE
OVERLAPPING RIBS.
PIPE PENETRATION DETAIL
Scale: N.T.S.4
PENETRATION DETAIL
Scale: N.T.S.5
NEW STAINLESS-STEEL DRAW BAND
NEW RUBBER ROOF JACK, INSTALL AS PER
MANUFACTURER'S SPECIFICATIONS
FASTEN AS PER MANUFACTURER'S
SPECIFICATIONS
NEW MFR'S APPROVED SEALANT
TOOLED TO FACILITATE RUNOFF
NEW GASKETED FASTENERS TO
SECURE FLASHING COLLAR
FLANGE TO ROOF PANEL
EXISTING PIPE - EXTEND AS
NECESSARY FOR 12" MINIMUM
FLASHING HEIGHT (IF NECESSARY)
FASTENER SPACED 1.5" O.C.
(COLOR TO MATCH ROOF PANEL)
SLOPE
TYPICAL METAL ZEE CLOSURE - SET
IN BUTYL TAPE SEAL (COMPLETELY
SEAL ALL JOINTS)
(PBR)- PANEL METAL ROOF
PRE-MOLDED PIPE FLASHING BOOT
FASTEN PER MANUFACTURER'S
RECOMMENDATIONS
EXTEND EXISTING STACK
AS NECESSARY TO
PROVIDE 12" HEIGHT
STAINLESS STEEL CLAMPING RING
PIPE EXTENSION (IF NECESSARY)
INSULATION SYSTEM
PBR- PANEL METAL ROOF
8" M
IN
2" M
IN
1/2"
MAX.
2" MIN.
3"
TYP.
3" TY
P.
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text
EAVE STRUT
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER
AutoCAD SHX Text
ATTACHMENT
AutoCAD SHX Text 1/4-14 x 7/8 LONG-LIFE LAPTEK
AutoCAD SHX Text
W/WASHER
AutoCAD SHX Text
PBR ROOF PANEL
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
(2) RUNS OF 1/2" x 3/32"
AutoCAD SHX Text
TAPE SEALER (MUST BE
AutoCAD SHX Text
INSTALLED BETWEEN WEATHER
AutoCAD SHX Text
INFILTRATION POINT & FASTENER)
AutoCAD SHX Text
LOWER PBR ROOF PANEL
AutoCAD SHX Text 12-14 x 1 1/4 LONG-LIFE SELF-
AutoCAD SHX Text
DRILLER W/WASHER (6) PER PANEL
AutoCAD SHX Text
UPPER PBR ROOF PANEL
AutoCAD SHX Text
%%USECTION 'A-A'
AutoCAD SHX Text
%%USECTION 'B-B'
AutoCAD SHX Text 1/4-14 x 7/8 LONG-LIFE LAPTEK
AutoCAD SHX Text
W/WASHER @ 20" O.C.
AutoCAD SHX Text
PBR ROOF PANEL
AutoCAD SHX Text 1/2" x 3/32" TAPE SEALER
AutoCAD SHX Text
%%UENDLAP SEALANT DETAIL
AutoCAD SHX Text
LOWER PBR ROOF
AutoCAD SHX Text 1/2" x 3/32" TAPE SEALER
AutoCAD SHX Text
@ SIDELAP
AutoCAD SHX Text
(2) RUNS OF 1/2" x 3/32"
AutoCAD SHX Text
TAPE SEALER @ ENDLAP
AutoCAD SHX Text 1/2" x 3/32" TAPE SEALER
AutoCAD SHX Text
(MARRY SIDELAP & ENDLAP
AutoCAD SHX Text
TAPE SEALERS)
AutoCAD SHX Text
UPPER PBR ROOF PANEL
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
BASE ANGLE (16 GA. MIN.)
AutoCAD SHX Text
(3) PER PANEL @ INTERMEDIATE
AutoCAD SHX Text
(6) PER PANEL
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text J
| Sheets and Views |
| COVER |
| A-0 STRUCT NOTES |
| A-1 SITE PLAN |
| A-2 FLOOR PLAN |
| A-3 ELEVATIONS |
| A-4 SECTIONS |
| A-5 DETAILS |
| A-6 STANDARD DETAILS |
| A-7 STANDARD DETAILS |
File details come from the government source that posted it. Updated .