ESBD_360087_1716315827411_EXHIBIT G - FERTITTA CENTER.pdf
PDF 2 MB Posted
- Attached to
- RFP730-24070 Athletics Production Services
- Solicitation number
- RFP730-24070
- Issued by
- Harris County, Houston City, Texas
About this file
This document contains a floor plan and other architectural details for the Fertitta Center, a sports facility located in Houston, Texas. The document is part of a state and local contract opportunity issued by the University of Houston Athletics Department, requesting proposals from external production companies to package a minimum of 50 intercollegiate athletic events per year, projected to begin in August 2024. The format for the production services is required to be 720p or 1080i. Respondents are encouraged to propose contractual arrangements that offer maximum benefit to the University in terms of services, overall cost, and project management expertise. Pricing should include per-game pricing, as well as any volume discounts after a certain number of events. Respondents are also asked to provide a short executive summary of their company operations and historical experience producing college sporting events, along with any applicable educational, state, and local government discounts.
The document also includes details on the Fertitta Center facility, including floor plans, room names and sizes, and general architectural notes. This information is likely provided to give respondents an understanding of the venue where the production services will be delivered.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
UP
UP
UP
UPUP
UP
18 20 23 24 26 27 28 30
P
V
F
K
G
D
C
B
O
R
T
U
16 17 19
A
A7.01
A7.01
EVENT FLOOR
100100
EXIST. STAIR
TO REMAIN
EXIST. RAMP
TO REMAIN
VENDOR
COMMISSARY
WOMENS'
RESTROOM
MENS'
RESTROOM
COURTSIDE
CLUB
EXISTING LOADING DOCK TO REMAIN
CPT OFFICE
HR OFFICE
MGS OFFICE
ROTC
CORRIDOR
80E80E
SUPPLY &
BREAK ROOM
ADMIN OFFICE
ADMIN OFFICE
26A26A
RECEPTION
ROTC
CORRIDOR
WOMEN'S TLT
MENS
RESTROOM
VAULT/
STORAGE
CADET STAFF
OFFICE
SFC OFFICE
OFFICE
CLOTHING &
SUPPLY
STORAGE
44A44A
IT
44B44B
CORRIDOR
STORAGE
44D44D
LAB & LOUNGE
44E44E
MECHANICAL
44F44F
CLASSROOM
44G44G
CLASSROOM
44H44H
CORRIDOR
VEST.
44J44J
CLASSROOM
44K44K
CORRIDOR
84A84A
STORAGE
44JA44JA
MECHANICAL
MECH.
STORAGE
STORAGE
29B29B
ELEC.
29C29C
VEST.
31B31B
PRIMARY
ELECTRICAL
ROOM
EXISTING
ELECTRICAL
ROOM
73A73A
PUMP ROOM
TUNNEL EAST
C16C16
PREMIUM
CORRIDOR
C12C12
NEW CONC. RAMP FROM
ROTC ENTRY TO GRADE
WARMING
KITCHEN
EXIST. RAMP AND
LANDING TO REMAIN
EXIST. STAIR
TO REMAIN
EXIST. SEATING
BOWL TREADS
AND RISERS
UP
DN
EXISTING SIDEWALK TO REMAINEXISTING GATE TO REMAIN
WOMENS'
RESTROOM
UP
NEW CONCRETE
RETAINING WALL
NEW RAISED
PLANTER
GAMEDAY
ROOM
GAMEDAY
RESTROOM
COACH'S
MEETING ROOM
CORRIDOR
C14C14
RAMP
C15C15
STORAGE
PREMIUM
LOBBY
L10L10
SIDELINE CLUB
21 22 25
MENS'
RESTROOM
SW RAMP
C13C13
11 9
D'
D'
E'
E'
F'
F'
MECH.
EXIST. STAIR
TO REMAIN
DN
DN
DN
DN
MECH.
STORAGE
B'
B'
ELEV. MACHINE
ROOM
STAIR
A1A1
ELEV.
E11E11
TUNNEL WEST
C11C11
TRAINING ROOM
68A68A
12 32
A1.20
SIDELINE CLUB
BAR
64E64E
STORAGE
54C54C
COURTSIDE
CLUB BAR
64D64D
BAR STORAGE
61B61B
JANITOR
61A61A
EXIT
ENCLOSURE
84A84A
CORRIDOR
61C61C
64A64A
64B64B
63A63A
C'
C'
ENTRY
61D61D
SERVING AREA
64F64F
ELEV. LOBBY
54B54B
'-4
'-1 0"
'-1
0"
'-6
6' -4
'-0
'-4
'-4
'-4
'-4
'-4
'-2
'-8
'-8
'-0
19'-3 5/8" 27'-0" 15'-0" 30'-4" 30'-4" 20'-2 1/2" 20'-3" 20'-2 1/2" 20'-2 1/2" 20'-3" 20'-2 1/2" 20'-4 1/2" 20'-4 1/2" 20'-4 1/2" 20'-4 1/2"
6"
S
H
MEDIA/ PRESS
CONFERENCE
ROOM
GREASE
INTERCEPTOR
ROOM
72D72D
CORRIDOR
C10AC10A
GREASE
INTERCEPTOR
ROOM
44I44I
ADJACENT BASKETBALL
DEVELOPMENT
CENTER. (N.I.C.)
ADJACENT BASKETBALL
DEVELOPMENT
CENTER. (N.I.C.)
OPEN TO
ABOVE
OPEN TO
ABOVE
OPEN TO
ABOVE
SIDELINE CLUB
LOGE
54.154.1
SIDELINE CLUB
THEATER LOGE
54.254.2
R16 9'-2
A4.10
168°
CHASE
NEW M.O.
7'-4"
BDF ROOM
72C72C
CORRIDOR
C16AC16A
VISITOR
LOCKER ROOM
B
VISITOR
LOCKER ROOM
A
VISITOR
RESTROOM A
80A80A
VISITOR
RESTROOM B
75A75A
VISITOR
COACH'S
OFFICE B
72B72B
VISITOR
COACHES
OFFICE A
VISITOR
COACHES
RESTROOM
81A81A
CORRIDOR
LOUNGE
21A21A
LOCKER ROOM
21B21B
SHOWERS
11A11A
TRAINING
OFFICIALS
CHANGING
ROOM
11C11C
KITCHENETTE
PLAN LEGEND
EXISTING- NOT IN SCOPE OF WORK
NEW FIRE SPRINKLERS ONLY
SEE REF SHEET
ADD ALTERNATE SCOPE OF WORK
EXISTING WALL OR COMPONENT TO REMAIN
EXISTING DOOR TO REMAIN
EXISTING WALL TO REMAIN
NOTE: REFER TO S0.03 FOR GRID AND WAYPOINT GEOMETRY PLAN
1HR RATED WALL RE: AND
2HR RATED WALL RE: AND
A0.10 A0.11
A0.10 A0.11
EXISTING PERIMETER CAST-IN-PLACE WALL TO
REMAIN
GENERAL NOTES
1. REFER TO SHEETS G0.02 - G0.22 FOR ALL PROJECT INFORMATION, ACCESSIBILITY
STANDARDS AND STANDARD MOUNTING HEIGHTS.
2. REFER TO SHEETS A0.10 - A0.11 FOR PARTITION TYPES.
3. REFER TO SHEETS A0.20 AND A0.25 FOR FINISH LEGENDS AND FINISH SCHEDULES.
4. REFER TO SHEETS A0.30 - A0.41 FOR DOOR, WINDOW AND LOUVER TYPES AND
SCHEDULES.
5. REFER TO A3.00 SERIES FOR REFLECTED CEILING PLANS.
6. REFER TO A6.00 SERIES FOR BUILDING ELEVATIONS.
7. REFER TO A7.00 SERIES FOR WALL SECTIONS AND DETAILS.
8. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
9. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ALL FLOOR OPENINGS.
10. GENERAL CONTRACTOR TO PROVIDE AND COORDINATE TREATED WOOD BLOCKING
REQUIREMENTS FOR ALL MILLWORK AND VISUAL DISPLAY SURFACES.
11. GENERAL CONTRACTOR TO COORDINATE SIZES AND LOCATIONS FOR ALL FLOOR
OPENINGS WITH EQUIPMENT MANUFACTURER REQUIREMENTS.
12. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION LOCATIONS.
DIMENSIONS, TYPES, DOORS AND WINDOWS SHALL BE AS SHOWN ON FLOOR PLAN. IN
CASE OF CONFLICT, NOTIFY ARCHITECT FOR WRITTEN CLARIFICATION PRIOR TO
PROCEEDING WITH CONSTRUCTION. FLOOR PLANS BY ARCHITECT SUPERCEDE OTHER
PLANS FOR LAYOUT.
13. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, U.N.O. DIMENSIONS
MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF FINISHES
INCLUDING CARPET, TILE, VCT, ETC. CONTRACTOR SHALL NOT ADJUST DIMENSIONS
WITHOUT WRITTEN INSTRUCTION FROM THE ARCHTIECT.
14. CONTRACTOR SHALL INSTALL GYPSUM BOARD FURRING TO ACCOMMODATE DEPTH OF
FIRE EXTINGUISHER CABINET / HOSE CABINET, ELECTRICAL PANEL BOARDS, AND OTHER
ITEMS INDICATED ON DRAWINGS AS RECESSED INTO GYPSM BOARD CONSTRUCTION.
CONTRACTOR SHALL COORDINATE DEPTH AND SIZE OF RECESS REQUIRED WITH
SPECIFIED EQUIPMENT.
15. EXPOSED GYPSUM BOARD EDGES SHALL HAVE METAL TRIM. PROVIDE CORNER BEADS
ALONG FULL LENGTH OF OUTSIDE CORNERS AND J BEADS ALONG ENDS OF GYPSUM
BOARD.
16. SLOPE TO FLOOR DRAINS NOT TO EXCEED 1:48 IN ALL DIRECTIONS.
NW NE
SE
MATCHLINE
M A
T C
H L
IN
E M
A T
C H
L
IN
E
MATCHLINE
SW
HOUSTON, TX 77042
3131 BRIARPARK DR.
SUITE 200
T 713 622 1444
F 713 968 9333
PGAL
CHECKED BY:
SHEET TITLE:
DRAWN BY:
COPY RIGHT:
SHEET NO. OF
PROJECT INFORMATION:
UH PROJECT No.
ORIG. ISSUE:
FLOOR NUMBER:
CITY/ZIP:
ADDRESS:
BUILDING NAME:
BLDG. ABBREV.:
BLDG. NUMBER:
PARCEL NUMBER:
CAMPUS NAME:
CONSULTANTS
SEAL (S):
F
O R
R E
D U
C E
D P
L A
N S o ri g in a l s c a le i n i n c h e s
University of Houston System
F
IL
E N
A M
E /B
Y
D A
T E
S T
A M
P
KEY PLAN:
DRAWING HISTORY:
Design Architect
AECOM
2380 McGee, Suite 200 Kansas City, MO 64108 Tel: 816.221.4443
S00035
FERTITTA CENTER
3422 CULLEN BLVD
HOUSTON, TX 77204
B
IM
/F e rt it ta
C e n te r/ U
H -A re n a -A
R C
H .r v t
/1
/2
:0 :5
A
M
12/10/2018
12/10/2018
FIRST LEVEL -
FLOOR PLAN -
OVERALL
A2.01
FERTITTA CENTER
© 2017
03/10/2017
PGAL-AECOM
PGAL-AECOM
1/16" = 1'-0" 1FIRST LEVEL - FLOOR PLAN - OVERALL
A
D
L U
T
BONN
E
P
E T
1 26 3 7A T
T S
X
ETE
FO
S A
R E G
IS
TE
RED
ARCH
IT
E C T
№. DATE DESCRIPTION
A 03/10/2017 100% CONSTRUCTION DOCUMENTS
1 03/30/2017 ADDENDUM 01
2 05/10/2017 ASI No. 1
3 07/05/2017 ASI No. 6
4 09/25/2017 ASI No. 10
5 02/26/2018 ASI No. 15
6 04/20/2018 ASI No. 18
7 05/14/2018 ASI No. 19
8 12/10/2018 ASI NO. 26
DN
PP
VV
L'
FF
K K
M
J
G G
E
D
D
C C
B B
O O
R R
T T
U U
H'
G'
A A
SW LOBBY
L100L100
MECH.
118118
CONCESSIONS
117117
STORAGE
113113
NOVELTY SALES
ZONE
115115
TICKETING
116116
FAMILY TOILET
123123
WOMEN'S
RESTROOM
122122
ELEC.
125125
HAWKER ROOM
124124
SUITE 2
127127
HALL OF FAME
ZONE
130130
ELEC.
134134
MECH.
138138
TICKETING
140140
MECH.
103103
ELEC.
101101
MENS'
RESTROOM
104104
AUDIO/VISUAL
109A109A
FAMILY ZONE
107107
WOMENS'
RESTROOM
108108
FIRST AID
111111
NE LOBBY
L101L101
SUITE 1
105105
NORTH
CONCOURSE
C100C100
MECH.
133133
ELEC.
141141
AUDIO/ VISUAL
119A119A
NE VESTIBULE
L101AL101A
SW VESTIBULE
L100AL100A
WEST
CONCOURSE
C101C101
SOUTH
CONCOURSE
C102C102
STAIR LOBBY
L103L103
LED/AUDIO
OPERATIONS
128128
WOMENS
RESTROOM
139139
FAMILY TOILET
102102
CONCESSIONS
137137
IT/AV
136136
AUDIO/VISUAL
131A131A
JAN. CLOSET
142142
ELECTRICAL
114114
SPRINKLER
VALVE ROOM
120120
ELEC.
110110
JANITORS
CLOSET
108B108B
FS PREP
117A117A
FS PREP
129A129A
CONCESSIONS
129129
FS PREP
106A106A
CONCESSIONS
106106
EXIST. BUILDING
EDGE OF FASCIA ABOVE
N
A4.11
A4.11
D'
D'
EXIST. CONC. STAIR
TO REMAIN
EXIST. LOADING DOCK
TO FIRST FLOOR
DN
NEW SW PLAZA
EXIST. FASCIA
ABOVE
EXISTING
RAM
P
BELO
W
NEW CONC.
SITE STAIR
TV TRUCK
CONNECTION
EXIST. CONC.
SITE STAIR
CONC.
SIDEWALK
EVENT FLOOR
100100
WOMENS
RESTROOM
112112
TV PRODUCTION TRUCK
JAN. CLOSET
106B106B
JAN. CLOSET
129B129B
R171'-2"
R117'-2"
R 117'-8"
R 171'-2"
R171'-2"
R
1' -2
R171'-2"
R137'-0"
R117'-2"
R 117'-8"
R 171'-2"
R
1' -2
R171'-2"
R 137'-0"
R137'-0"
R
7' -4
/4
R
' -0
R 137'-0"
R A
D
IA
L G
U
ID
E L
IN
E
-A
RADIAL G
UIDE LINE-B
RADIAL GUIDE LINE-D
R
AD
IA
L G
U
ID
E LIN
E-E
R A
D
IA
L G
U
ID
E L
IN
E
-G
RADIAL G
UIDE LINE-H
RADIAL GUIDE LINE-K
R
AD
IA
L G
U
ID
E LIN
E-L
'-0
/8
'-1
/2
'-7
/2
33'-6 3/8"108'-7 5/8"
B.8
D.9
A.1
14.9 17.814.1
U.5
29.3
WP3
WP4
WP2
WP5
WP1
B'
B'
EXIST. MEP
PENETRATION VIF
C.4
16.6
'-0
JAN. CLOSET
143143
JAN. CLOSET
144144
R187'-4 3/4"
R
7' -4
/4
STORAGE
119C119C
IT
119B119B
IT
131B131B
IT
109B109B
EXISTING ELECTRICA
GENERATOR AND PAD
FS PREP
137A137A
C'
C'
S S
H H
R137'-0 1/2"
WOMEN'S
RESTROOM
126126
WOMEN'S
RESTROOM
VEST
112A112A
WOMEN'S
RESTROOM
VEST
122A122A
WOMEN'S
RESTROOM
VEST
126A126A
CONCESSIONS
129C129C
MEN'S
RESTROOM
VEST
132A132A
EAST TERRACE
135135
TICKETING
116A116A
SW LOBBY
L100BL100B
NE LOBBY
L101BL101B
TICKETING
140B140B
STAIR
A1A1
MEN'S
RESTROOM
132132
EPOXY FLOOR JOINTS ALIGN
W/PENDANT LIGHTS ABOVE
EPOXY FLOOR JOINTS ALIGN
W/PENDANT LIGHTS ABOVE
8°
8°
8°
8°
8°
8°
RE: S0.10 FOR LOCATION
OF GEOMETRY WORK POINTS.
WEST PREMIUM
SEATING
54.354.3
PLAN LEGEND
EXISTING- NOT IN SCOPE OF WORK
NEW FIRE SPRINKLERS ONLY
SEE REF SHEET
ADD ALTERNATE SCOPE OF WORK
EXISTING WALL OR COMPONENT TO REMAIN
EXISTING DOOR TO REMAIN
EXISTING WALL TO REMAIN
NOTE: REFER TO S0.03 FOR GRID AND WAYPOINT GEOMETRY PLAN
1HR RATED WALL RE: AND
2HR RATED WALL RE: AND
A0.10 A0.11
A0.10 A0.11
EXISTING PERIMETER CAST-IN-PLACE WALL TO
REMAIN
GENERAL NOTES
1. REFER TO SHEETS G0.02 - G0.22 FOR ALL PROJECT INFORMATION, ACCESSIBILITY
STANDARDS AND STANDARD MOUNTING HEIGHTS.
2. REFER TO SHEETS A0.10 - A0.11 FOR PARTITION TYPES.
3. REFER TO SHEETS A0.20 AND A0.25 FOR FINISH LEGENDS AND FINISH SCHEDULES.
4. REFER TO SHEETS A0.30 - A0.41 FOR DOOR, WINDOW AND LOUVER TYPES AND
SCHEDULES.
5. REFER TO A3.00 SERIES FOR REFLECTED CEILING PLANS.
6. REFER TO A6.00 SERIES FOR BUILDING ELEVATIONS.
7. REFER TO A7.00 SERIES FOR WALL SECTIONS AND DETAILS.
8. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
9. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ALL FLOOR OPENINGS.
10. GENERAL CONTRACTOR TO PROVIDE AND COORDINATE TREATED WOOD BLOCKING
REQUIREMENTS FOR ALL MILLWORK AND VISUAL DISPLAY SURFACES.
11. GENERAL CONTRACTOR TO COORDINATE SIZES AND LOCATIONS FOR ALL FLOOR
OPENINGS WITH EQUIPMENT MANUFACTURER REQUIREMENTS.
12. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN PARTITION LOCATIONS.
DIMENSIONS, TYPES, DOORS AND WINDOWS SHALL BE AS SHOWN ON FLOOR PLAN. IN
CASE OF CONFLICT, NOTIFY ARCHITECT FOR WRITTEN CLARIFICATION PRIOR TO
PROCEEDING WITH CONSTRUCTION. FLOOR PLANS BY ARCHITECT SUPERCEDE OTHER
PLANS FOR LAYOUT.
13. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, U.N.O.
DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR
THICKNESS OF FINISHES INCLUDING CARPET, TILE, VCT, ETC. CONTRACTOR SHALL NOT
ADJUST DIMENSIONS WITHOUT WRITTEN INSTRUCTION FROM THE ARCHTIECT.
14. CONTRACTOR SHALL INSTALL GYPSUM BOARD FURRING TO ACCOMMODATE DEPTH OF
FIRE EXTINGUISHER CABINET / HOSE CABINET, ELECTRICAL PANEL BOARDS, AND
OTHER ITEMS INDICATED ON DRAWINGS AS RECESSED INTO GYPSM BOARD
CONSTRUCTION. CONTRACTOR SHALL COORDINATE DEPTH AND SIZE OF RECESS
REQUIRED WITH SPECIFIED EQUIPMENT.
15. EXPOSED GYPSUM BOARD EDGES SHALL HAVE METAL TRIM. PROVIDE CORNER BEADS
ALONG FULL LENGTH OF OUTSIDE CORNERS AND J BEADS ALONG ENDS OF GYPSUM
BOARD.
16. SLOPE TO FLOOR DRAINS NOT TO EXCEED 1:48 IN ALL DIRECTIONS.
NORTH
PLAN
NW NE
SE
MATCHLINE
M A
T C
H L
IN
E M
A T
C H
L
IN
E
MATCHLINE
SW
HOUSTON, TX 77042
3131 BRIARPARK DR.
SUITE 200
T 713 622 1444
F 713 968 9333
PGAL
CHECKED BY:
SHEET TITLE:
DRAWN BY:
COPY RIGHT:
SHEET NO. OF
PROJECT INFORMATION:
UH PROJECT No.
ORIG. ISSUE:
FLOOR NUMBER:
CITY/ZIP:
ADDRESS:
BUILDING NAME:
BLDG. ABBREV.:
BLDG. NUMBER:
PARCEL NUMBER:
CAMPUS NAME:
CONSULTANTS
SEAL (S):
F
O R
R E
D U
C E
D P
L A
N S o ri g in a l s c a le i n i n c h e s
University of Houston System
F
IL
E N
A M
E /B
Y
D A
T E
S T
A M
P
KEY PLAN:
DRAWING HISTORY:
Design Architect
AECOM
2380 McGee, Suite 200 Kansas City, MO 64108 Tel: 816.221.4443
S00035
FERTITTA CENTER
3422 CULLEN BLVD
HOUSTON, TX 77204
B
IM
/F e rt it ta
C e n te r/ U
H -A re n a -A
R C
H .r v t
/2
/2
:0 :2
P
M
02/26/2018
02/26/2018
CONCOURSE LEVEL
- FLOOR PLAN -
OVERALL
A2.02
FERTITTA CENTER
© 2017
03/10/2017
PGAL-AECOM
PGAL-AECOM
1/16" = 1'-0" 1CONCOURSE LEVEL FLOOR PLAN OVERALL
A
D
L U
T
BONN
E
P
E T
1 26 3 7A T
T S
X
ETE
FO
S A
R E G
IS
TE
RED
ARCH
IT
E C T
№. DATE DESCRIPTION
A 03/10/2017 100% CONSTRUCTION DOCUMENTS
1 03/30/2017 ADDENDUM 01
2 02/26/2018 ASI No. 15
File details come from the government source that posted it. Updated .